Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC | ₹1.6 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.6 Cr+₹999.96 (<0.01%)Rejected-AOC | ₹1.6 Cr+₹999.96 (<0.01%) | L2 | Rejected-AOC L2 |
| 3 | L3₹1.6 Cr+₹1,800.29 (0.01%)Rejected-AOC | ₹1.6 Cr+₹1,800.29 (0.01%) | L3 | Rejected-AOC L3 |
Tender Value
₹1.5 Cr
EMD Value
₹3.1 L
Closing Date
20 Jan 2021, 4:30 pmClosed
Sri Hridoy Boro
O/o the Addl. Chief Engineer cum Director, PWD,Kokrajhar
Construction of Asstt. Commissioners Qtr. Ground Floor for four units at Kajalgaon in Chirang District BTC, Assam.
2021_BTC_19973_1
No. ACE- 05/CHN/IFB/2018-19/244
Open Tender
Civil Works - Building
Item Rate
720 days
Chirang
Please refer Tender documents.
6 documents required · 6 mandatory
₹4,700
The Principal Secretary, BTC, Kokrajhar
₹3.1 L
Yes
11 Mar 2021
6 Jan 2021
21 Jan 2021
6 Jan 2021
20 Jan 2021
6 Jan 2021
6 Jan 2021 - 20 Jan 2021
Amount
(A) Construction of Ground Floor Building: Earthwork in excavation for foundation trenches of walls, retaining walls, footing of column, steps, septic tank etc. including refiling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead & lift as directed and specified in following classification of soils including bailing out water where necessary as directed and spedified. (A) Up to depth of 2.0 m below the existing Ground Level (a) In Ordinary Soil.
Providing brick soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a) Brick on flat soling.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop. 1:3: 6 (1 cement: 3 coarse sand : 6 coarse agg. by volume (using mixture machine)
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor level). a) From Primary Producer: TATA/SAIL/Esser Steel/Jindal Steel/Shyam Steel/RINL (i) TMT Corrosion resistant steel (CRS) reinforcement bar.
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc. hight of proping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in: 3.1.1.1. Foundation, footing, base of colums, pile cap, raft and mass concrete works etc. (i) Using 25mm thick plank
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc. hight of proping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.1. Colums, pillars, posts & strut square, rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face.
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc. hight of proping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.2. Sides and soffits of beams, beam haunching, cantilever, girders, bressumers lintelsand horizontal ties. (a) For depth not exceeding 1.0M.
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc. hight of proping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.3. Flat Surface such as soffts of suspended floors roofs landings cantelever slabs chajjas balconies and the like. (a) Floors etc. upto 200mm in thickness
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc. hight of proping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.5. Sloping or battering surface such as sloped slabs etc. including folded plates. (a) Where inclination to horizontal plane does not exceed 30 requiring shuttering only on the underside.
Providing and laying plain/reinforced cement concrete works cement with coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding coast of from work and reinforcement for reinforce cement concrete work. (from work and reinforcement will be measured and paid separately) (i) Using mixture machine (a) In Sub-Structure up to plinth level Foundation, footing, colums with base, tie & plinth beam, pile cap, base slab,retaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level. (N) With out admixture, plasticiser (b) M-20 grade concrete ro prop.1:1.5:3
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-Structure upto plinth level including dewatering if necessary (b) In proportion 1:4
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming, etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (C) With silt (predominantly non plastic) by truck carriage including loading and unloading.
Providing and laying plain/reinforced cement concrete works cement with coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding coast of from work and reinforcement for reinforce cement concrete work. (from work and reinforcement will be measured and paid separately) (i) Using mixture machine (b) In Super Structure from plinth level up to floor level. (ii) Colums, pillars, posts, struts, suspended floor, roof landing , shelf & support balcony, lintel, sill band, beam, girder, bressumer, cantilever, stair case (except spiral stair case and landing) including preparing the top surface & finishing of nosing. (N) With out admixture, plasticiser (b) M-20 grade concrete ro prop.1:1.5:3
Providing and laying 25mm thick damp proof coarse with cement concrete in prop 1:1.5:3 with graded store agg. Stone of 10mm down nominal size including providing approved damp proof admixture in proparation of recommended by the manufacturer including curing etc.complete as directed.
112mm thick 1st class brick nogged wall in cement morter including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall (b) In cement mortar in proporation 1:4 (1 cement: 4 sand)
Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 corse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (a) 15mm thick.
Providing, fitting and fixing coloured anodised aluminium windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels. (Cement concrete to be measured and paid separately). a)Side hung and Top hung windows and ventilators (iv) 5 mm clear glass
Providing, fitting and fixing coloured anodised aluminium windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels. (Cement concrete to be measured and paid separately). (b)Fixed windows and ventilators (iv) 5 mm clear glass
Providing, fitting and fixing anodised aluminuim framed glazed doors with anodised aluminium frame made of 100mm x 45mm x 2.5mm section of approved brand with door style of size 88mm x 45mm x 2.5mm, top rails 50mm x 45mm x 2mm lock rails 100mm x 45mm x 2mm and bottom rails 100mm x 45mm x 2.5mm fitted with glazing clip, special type rubber gasket complete including hydraulic floor spring, pivot, tower bolt in each leaf, aluminium door handle, lock, angles, cleat etc complete as specified and directed by the department at all levels. (iv) Prelaminated Board
Providing, fitting and fixing 40mm x 48mm wood reinforced PVC chowkhats fixed to the columns / stiffeners / walls with necessary holdfast / sleeves etc. as specified and directed at all levels.
Providing, fitting and fixing 24mm/ 29mm thick polymer reinforced moulded PVC door shutters fixed to the chowkath with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperately) b) 29mm thick
Providing and fixing 12mm thick and 150mm wide pelmet with 25mm dia wooden curtain rod and bracket including ficing with 15mm x 3mm M.S flat 100mm long plugs complete. E) Extra for providign and fixing bars curtain rail with rollers, stoppers and brakets in pelmet instead of wooden curtain rods 25mm dia with brakets (actiatl length of the rods to be measured)
Providing fitting and fixing M.S grill of requiredpattern for windows/clerestory windows/opening with M.S flats at required spacing in frame all round squre or round M.S bars with round headed bolts and nuts or screws. I. Plain grill (c) Fixed to Brickwork/PCC/RCC
Providing and fitting stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc. including welding, grinding, buffing polishing and making curvature (wheraver required) and fitting the same with necessary stainless steel nuts and bolts complete, i.e. fixing the railing with neccessary accessories & stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of engineer in charge. (for payment, only weight of stainless steel member is to be considered. no extra payment for fixing accessories such as nuts, bolts, fasteners etc. will be considered.)
Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete. c) 100mm thick
VITRIFIED TILES A) ON FLOOR Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) b) Executive range i) Of size 800mm x 800mm and above
B) ON WALLS Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. (coloured pigment should be in conformity with colour of tiles and as approved and directed by the department). i) Of size 300mm x 450mm and above
18mm thick marble stone slab flooring of size 1200 x 1200 including treads and risers of steps, skirting laid over 20mm thick base of cement plaster 1:6 (1cement: 6 coarse sand) laid and joined with grey cement slurry including rubbing and polishing complete with marble slab of specified quality and shade at all levels. (i) Dungri slab
15mm thick cement plaster in single coat on rough side of single half brick wall for interior plastering upto 1st floor level including arrises, internal round angle not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. A) On rough side (b) In cement mortar 1:4 (1 cement : 4sand)
Providing surface preparation for walls, ceilling etc, using average 1.50mm thick plaster of paries of pares including rubbing with sand paper filling gaps, depression etc. where necessary with chalk powder and plaster of pairs paste making the surface even and smooth complete at all levesl as specified and directed.
Providing two coats of acrylic water based wall putty/ wall filter of Asian Paints/Berger/ Dulux over concrete/cement plaster/brick walls and ceilling both internal and external after removing all the loosely adhering material from the wall/ceilling surface with the help of emery stone, putty blade or wire brush, moisterning the wall with the help of sufficient quantity of clear water as specified and directed by the department.
Wall Painting (two coats) with plastic emulsion paint of approved brand and manufacture (Asian/paint/Berger paint/ICII paint/J & N /Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a) Plastic Emulsion Paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J & N paint/Nerolac)
Applying one self-priming coat of acrylic emulsion paint of approved brand, thining by adding water as per the specification of manufacturer over freshly plastered wall surface after thoughly brooming the surface free mortar droppings and other foreign matter and including preparing the surface even and sand papered as specified and directed by the department. C) Asian paint.
Finishing wall with two coats of acrylic emulsion exterior paint of approved brand of required shade thinning by adding water as per specification of manufacturer after throughly brooming the surfaces to removed all dirt and remains of loose powdered materials as specified and directed by the department. C) Asian paint
Applying primary coat over new steel and other metal surfaces over 100mm in width or girth after preparing the surface by throughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. (a) With ready mixed "red-lead/red oxide" primer.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (i) Surfaces over 100mm in width or girth b) High gloss (Asian paint/Berger paint/ICI paint/J & N paint/Nerolac)
Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt and other foreign matter sand papering and knotting. (b) With ready mixed paint, wood primer (pink)
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J & N paint/Nerolic) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter sand papering and stopping. (i) Surfaces over 100mm in width or girth. b) High gloss (Asian paint/Berger paint/ICI paint/J & N paint/Nerolac)
Providing drain with brick work in cement mortar in prop 1:5 with half brick thick side walls and 100mm thick CC (1:3:6) base over one brick flat soiling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shettering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. (ii) 300 wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
Providing plinth protection with bricks flat laid in cement mortar 1:4 and finished with 15mm thick cement plaster in prop 1:2 with a floating coat of neat cement finish.
Providing, Fixing, testing & Commissioning of Single Headed Gun Metal ISI Marked oblique pattern Hydrant Landing Valve with 80 mm dia, flanged inlet & 63 mm dia instantaneous type female outlet complete with cap and chain, twist release lug and all accessories as per IS:5290-19833 (Type-'A') and specifications complete as reequired . (MAKE:ESSEL/WINCO/NEWAGE)
Providing and fixing clear sheet glass beded in putty and fixing with/wiithout wooden beadings including necessary cutting of glass to required sizes (payment for wooden beads shall be made separately). (2) Area of glass panes not exceeding 0.15sqm. but not exceeding 0.52m2. (b) 4.00mm thick
Sanitary Installation and Water Supply Works: Providing fitting and fixing vitreous china pedestal type water clost (European type W.C. pan 400mm high) with seat and lead, CP brass hinges and rubber buffers, CI/MS brackets, 40mm dia flush band with fittings including painting of fittings and brackets, required. A) Hindware make (i) Universal Closet S Trap (Cat.No.C0271) (Anglo Indian) (inclusive of seat cover)
Supplying fitting and fixing PVC flushing cisterm with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe union clams etc.complete as directed and specified (pipes will be measured separately) i) Parryware make a) White (i) Economy single flush (Cat No.C8090/C8055)
Providing fitting and fixing vitreous China flat back type lipped front urinal basin with standard flush pipe and CP. brass spreader and brass union, etc.complete including painting of fittings and brackets, cutting and making good the walls wherever required. A) Parryware make a) White (ii) Aquaseal (Cat No.C0508)
Providing fitting and fixing vitreous China flat back type lipped front urinal basin with standard flush pipe and CP brass spreader and brass union, etc.complete including painting of fittings and brackets, cutting and making good the walls wherever required. Basin (Without pedestal) A) Parryware Make a) White (i) Star Basin 550 x 400 (Cat. No.C0450)
Providing fitting and fixing Mirror with plastic frame of size 500 x 400mm complete as directed and specified.
Providing fitting and fixing recessed soap try/soap dish complete as directed and specified. A. Parryware Make. (i) Recess SP & SG dish (Cat No.C9935)
Providing fitting and fixing CP towel rail complete as directed and specified. (c) Parryware make (Cat. No.C9948)
Supplying fitting and fixing overhead adjustable Chrome Plated (C.P.) spray shower 15mm dia. of Sona make with wall flange as directed and specified.(pipes will be measured and paid separately) (b)Apex/Kiran/Priya/Star/RimZim/Bugle shower with arm
Supplying fitting and fixing approved uPVC Pipes of different sizes, with all necessary 'R' brand or similar approved P.V.C. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. (A) Exposed or in trenches SUPREME/ PRINCE/ SFMC BRAND or other equvalent approved brand (High presure pipe Sch-40) Exposed or in trenches d) 25 mm dia
Supplying fitting and fixing approved uPVC Pipes of different sizes, with all necessary 'R' brand or similar approved P.V.C. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. (A) Exposed or in trenches SUPREME/ PRINCE/ SFMC BRAND or other equvalent approved brand (High presure pipe Sch-40) Exposed or in trenches e) 20 mm dia (ii) Using other ISI marked approved brand.
Supplying fitting and fixing approved uPVC Pipes of different sizes, with all necessary 'R' brand or similar approved P.V.C. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. (A) Exposed or in trenches SUPREME/ PRINCE/ SFMC BRAND or other equvalent approved brand (High presure pipe Sch-40) Exposed or in trenches f) 15 mm dia (ii) Using other ISI marked approved brand.
Supplying fitting and fixing C.P. Bib cock 15mm dia of approved brand directed and specified. (G.I &C.P pipes will be measured separately) (I) Essco make (Delux/Sumthing spl.Tropical) (a) Bib cock short body
Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P.pipes will be measured and paid separately) I) Brass stop cock (heavy) of Sant make. (i) 15mm dia.
Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P.pipes will be measured and paid separately) I) Brass stop cock (heavy) of Sant make. (ii) 20mm dia.
Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P.pipes will be measured and paid separately) I) Brass stop cock (heavy) of Sant make. (iii) 25mm dia.
Supplying and fitting fixing C.P pillar cock of 15mm dia of approved brand as specification and directed. (ii) Jaguar make (a) Continental
Supplying fitting and fixing Chrome Plated (C.P) flush cock of approved brand as directed and specified (G.I & C.P pipes will be measured and paid separately) (I) Agmeco brand a) Flush cock Economy Cat No.00506
Supplying fitting and fixing chrome plated (C.P) wall mixer complete as directed. (ii) Agmeco brand a) Wall mixer non telephonic Cat No.00211
Supplying fitting and fixing pipes with all necessary fittings in exposed or in trenches or in trenches including trenches and refilling the same etc complete as directed. B) uPC pipe with uPC fittings (Using high pressure pipe) vii) 65mm diameter.
Supplying fitting and fixing pipes with all necessary fittings in exposed or in trenches or in trenches including trenches and refilling the same etc complete as directed. B) uPC pipe with uPC fittings (Using high pressure pipe) x) 110mm diameter.
Supplying fitting and fixing Hand pump for 40 mm dia tube well with all accessosires complete as directed. i) Maya popular-6
Labour for boring hole for inserting tube well pipes through different soil/rock media including hire charges of drill pipes, scaffolding, tools and plants as necesary and taking out the same and lowering pipes, fittings complete as directed by the department. iv) Bore hole of 150mm diameter.
Supplying fitting and fixing pipes plain/bevel ended for casing consorming to relevent IS codes of practice inclluding supplying and fitting of tube well accessories lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and foreign materials in the annular space between the borehole and assembly pipes complete as directed by the department. II. PVC PIPE SUPREME/PRINCE/FUSION/SFMC Brand vi) 140mm diameter
Supplying fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed. B) PVC PIPE SUPREME/PRINCE/FUSION/SFMC Brand vi) 75mm diameter
Supplying fitting and fixing ISI approved PVC filter 3.00 metre long. V) 150mm diameter
Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex/Polycon/Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes (i) 2000 Lt capacity (a) Sintex make
Single phase submersible motor pump set (Texmo/Crompton Gravels/Aquatic/CRI/V-Guar suitable for 100mm bore well and above. 1.5 HP STAGE 5 to 26 with control panel.
Septik Tank 2 Nos. Earth work in excavation for foundation trenches of walls, retaining walls.footing of colums,steps and septic tank etc. including refiling (return filling) the quantity as necessary after completing of work. breaking clods in return filling dressing. watering and ramming etc and removal of surplus earth with all lead & lift as directed and specified in following classification of soils including bailing out water where necessary as directed and spedified. (A) Up to depth of 2.0 m below the existing G.L (a) In Ordinary Soil.
Providing brick work soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparting the subgrade as directed including all labour and materials and if necessary dewatering complete. (a) Brick on flat soiling.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing, steps,walls,brick works etc. as directed and specified including dewatering if necessary and curing complete (Shuttering works where necessary shall be measured and paid separately.) (a) In prop. 1:3:6 (1 cement :3 coarse sand : 6 coarse agg. by volume. (using mixture machine).
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B. walling including straightening,cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks,supprots,chairs,spacers etc complete. (upto 1st floor level) c) ISI approved Mild steel reinforcement bar (M.S.Bar)
Flat surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. Upto 200mm in thickness (ii) Using 25mm thick plank.
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-Structure upto plinth level including dewatering if necessary (b) In proportion 1:4
Providing and laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding coast of from work and reinforcement for reinforce cement concrete work. (from work and reinforcement will be measured and paid separately) (i) Using Mixer Machine (a) In Sub-Structure up to plinth level Foundation, footing, colums with base, tie & plinth beam, pile cap, base slab,retaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level. N) Without using admixture plasticiser a) M-15 grade concrete or prop.1:2:4
15mm thick cement plaster in single coat on rough side of single half brick wall for interior plastering upto 1st floor level including arrises, internal round angle not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. A) On rough side (b) In cement mortar 1:4 (1 cement: 4 sand)
(B) Construction of First Floor Building: Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B. walling including straightening,cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks,supprots,chairs,spacers etc complete. (Upto 1st floor level) a) from Primary Producer: TATA/SAIL/Esser Steel/Jindal Steel/Shyam Steel/RINL (i) TMT Corrosion resistant steel(CRS) reinforcement bar.
3.2.1.1. Colums, pillars, posts & strut of square/rectangular/polygonal in plan or any shape like Tee/L etc.having plane vertical face.
3.1.1.2 Sides of tie beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M.
3.2.1.3 Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200mm in thickness.
Sloping or Battering sufaces such as sloped slabs etc. including folded plates. (a) Where inclination to horizontal plane does not exceed 30o requiring shuttering only on the underside.
Providing and laying plain/reinforced cement croncrete works cement with coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using mixture machine (B) In super structure from plinth level up to 1st floor level (ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. (N) with out admixture, plasticiser (b) M20 grade concrete ro prop. 1:1.5:3
112 mm thick 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) A) 112 mm thick brick wall (a). In cement mortar in proportion 1:4.(1 cement:4 sand)
Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (a) 15 mm thick
Providing, fitting and fixing coloured anodised aluminium windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels.(Cement concrete to be measured and paid separately). (a)Side hung and Top hung windows and ventilators (iv) 5 mm clear glass
Providing, fitting and fixing coloured anodised aluminium windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels.(Cement concrete to be measured and paid separately). (b)Fixed windows and ventilators (iv) 5 mm clear glass
Providing, fitting and fixing anodised aluminuim framed glazed doors with anodised aluminium frame made of 100mm x 45mm x 2.5mm section of approved brand with door style of size 88mm x 45mm x 2.5mm, top rails 50mm x 45mm x 2mm lock rails 100mm x 45mm x 2mm and bottom rails 100mm x 45mm x 2.5mm fitted with glazing clip, special type rubber gasket complete including hydraulic floor spring, pivot, tower bolt in each leaf, aluminium door handle, lock, angles, cleat etc complete as specified and directed by the department at all levels. (iv) Prelaminated Board
Providing, fitting and fixing 40mm x 48mm wood reinforced PVC chowkhats fixed to the columns / stiffeners / walls with necessary holdfast / sleeves etc. as specified and directed at all levels.
Providing, fitting and fixing 24mm/ 29mm thick polymer reinforced moulded PVC door shutters fixed to the chowkath with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperately) b) 29mm thick
Providing and fixing 12mm thick and 150mm wide pelmet with 25mm dia wooden curtain rod and bracket including ficing with 15mm x 3mm M.S flat 100mm long plugs complete. E) Extra for providign and fixing bars curtain rail with rollers, stoppers and brakets in pelmet instead of wooden curtain rods 25mm dia with brakets (actiatl length of the rods to be measured)
Providing fitting and fixing M.S grill of requiredpattern for windows/clerestory windows/opening with M.S flats at required spacing in frame all round squre or round M.S bars with round headed bolts and nuts or screws. I. Plain grill (c) Fixed to Brickwork/PCC/RCC
Providing and fitting stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc. including welding, grinding, buffing polishing and making curvature (wheraver required) and fitting the same with necessary stainless steel nuts and bolts complete, i.e. fixing the railing with neccessary accessories & stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of engineer in charge. (for payment, only weight of stainless steel member is to be considered. no extra payment for fixing accessories such as nuts, bolts, fasteners etc. will be considered.)
Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete. c) 100mm thick
VITRIFIED TILES A) ON FLOOR Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) b) Executive range Somany/Orient/Nitco /Varmora/VITA/ Marbito/ Make i) Of size 800mm x 800mm and above
B) ON WALLS Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. (coloured pigment should be in conformity with colour of tiles and as approved and directed by the department). i) Of size 300mm x 450mm and above
18mm thick marble stone slab flooring of size 1200 x 1200 including treads and risers of steps, skirting laid over 20mm thick base of cement plaster 1:6 (1cement: 6 coarse sand) laid and joined with grey cement slurry including rubbing and polishing complete with marble slab of specified quality and shade at all levels. (i) Dungri slab
15mm thick cement plaster in single coat on rough side of single half brick wall for interior plastering upto 1st floor level including arrises, internal round angle not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. A) On rough side (b) In cement mortar 1:4 (1 cement : 4sand)
Providing surface preparation for walls, ceilling etc, using average 1.50mm thick plaster of paries of pares including rubbing with sand paper filling gaps, depression etc. where necessary with chalk powder and plaster of pairs paste making the surface even and smooth complete at all levesl as specified and directed.
Providing two coats of acrylic water based wall putty/ wall filter of Asian Paints/Berger/ Dulux over concrete/cement plaster/brick walls and ceilling both internal and external after removing all the loosely adhering material from the wall/ceilling surface with the help of emery stone, putty blade or wire brush, moisterning the wall with the help of sufficient quantity of clear water as specified and directed by the department.
Wall Painting (two coats) with plastic emulsion paint of approved brand and manufacture (Asian/paint/Berger paint/ICII paint/J & N /Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a) Plastic Emulsion Paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J & N paint/Nerolac)
Applying one self-priming coat of acrylic emulsion paint of approved brand, thining by adding water as per the specification of manufacturer over freshly plastered wall surface after thoughly brooming the surface free mortar droppings and other foreign matter and including preparing the surface even and sand papered as specified and directed by the department. C) Asian paint
Finishing wall with two coats of acrylic emulsion exterior paint of approved brand of required shade thinning by adding water as per specification of manufacturer after throughly brooming the surfaces to removed all dirt and remains of loose powdered materials as specified and directed by the department. C) Asian paint
Applying primary coat over new steel and other metal surfaces over 100mm in width or girth after preparing the surface by throughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. (a) With ready mixed "red-lead/red oxide" primer.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J & N paint/Nerolic) to give an even shade including cleaning the surface of all dirt dust and other foreign matter. (i) Surface over 100 mm in width or girth. (b) High gloss (Asian paint/Berger paint/ICI paint/J & N paint/Nerolac)
Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt and other foreign matter sand papering and knotting. (b) With ready mixed paint, wood primer (pink)
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J & N paint/Nerolic) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter sand papering and stopping. (i) Surfaces over 100mm in width or girth. b) High gloss (Asian paint/Berger paint/ICI paint/J & N paint/Nerolac)
Providing and fixing clear sheet glass beded in putty and fixing with/wiithout wooden beadings including necessary cutting of glass to required sizes (payment for wooden beads shall be made separately). (2) Area of glass panes not exceeding 0.15sqm. but not exceeding 0.52m2. (b) 4.00mm thick
Sanitary Installation and Water Supply Works: Providing fitting and fixing vitreous china pedestal type water clost (European type W.C. pan 400mm high) with seat and lead, CP brass hinges and rubber buffers, CI/MS brackets, 40mm dia flush band with fittings including painting of fittings and brackets, required. A) Hindware make (i) Universal Closet S Trap (Cat.No.C0271) (Anglo Indian) (inclusive of seat cover)
Supplying fitting and fixing PVC flushing cisterm with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe union clams etc.complete as directed and specified (pipes will be measured separately) i) Parryware make a) White (i) Economy single flush (Cat No.C8090/C8055)
Providing fitting and fixing vitreous China flat back type lipped front urinal basin with standard flush pipe and CP. brass spreader and brass union, etc.complete including painting of fittings and brackets, cutting and making good the walls wherever required. A) Parryware make a) White (ii) Aquaseal (Cat No.C0508)
Providing fitting and fixing vitreous China flat back type lipped front urinal basin with standard flush pipe and CP brass spreader and brass union, etc.complete including painting of fittings and brackets, cutting and making good the walls wherever required. Basin (Without pedestal) A) Parryware Make a) White (i) Star Basin 550 x 400 (Cat. No.C0450)
Providing fitting and fixing Mirror with plastic frame of size 500 x 400mm complete as directed and specified.
Providing fitting and fixing recessed soap try/soap dish complete as directed and specified. A. Parryware Make. (i) Recess SP & SG dish (Cat No.C9935)
Providing fitting and fixing CP towel rail complete as directed and specified. (c) Parryware make (Cat. No.C9948)
Supplying fitting and fixing overhead adjustable Chrome Plated (C.P.) spray shower 15mm dia. of Sona make with wall flange as directed and specified.(pipes will be measured and paid separately) (b)Apex/Kiran/Priya/Star/RimZim/Bugle shower with arm
Supplying fitting and fixing approved uPVC Pipes of different sizes, with all necessary 'R' brand or similar approved P.V.C. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. (A) Exposed or in trenches SUPREME/ PRINCE/ SFMC BRAND or other equvalent approved brand (High presure pipe Sch-40) Exposed or in trenches d) 25 mm dia
Supplying fitting and fixing approved uPVC Pipes of different sizes, with all necessary 'R' brand or similar approved P.V.C. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. (A) Exposed or in trenches SUPREME/ PRINCE/ SFMC BRAND or other equvalent approved brand (High presure pipe Sch-40) Exposed or in trenches e) 20 mm dia (ii) Using other ISI marked approved brand.
Supplying fitting and fixing approved uPVC Pipes of different sizes, with all necessary 'R' brand or similar approved P.V.C. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. (A) Exposed or in trenches SUPREME/ PRINCE/ SFMC BRAND or other equvalent approved brand (High presure pipe Sch-40) Exposed or in trenches f) 15 mm dia (ii) Using other ISI marked approved brand.
Supplying fitting and fixing C.P. Bib cock 15mm dia of approved brand directed and specified. (G.I &C.P pipes will be measured separately) (I) Essco make (Delux/Sumthing spl.Tropical) (a) Bib cock short body
Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P.pipes will be measured and paid separately) I) Brass stop cock (heavy) of Sant make. (i) 15mm dia.
Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P.pipes will be measured and paid separately) I) Brass stop cock (heavy) of Sant make. (ii) 20mm dia.
Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P.pipes will be measured and paid separately) I) Brass stop cock (heavy) of Sant make. (iii) 25mm dia.
Supplying and fitting fixing C.P pillar cock of 15mm dia of approved brand as specification and directed. (ii) Jaguar make (a) Continental
Supplying fitting and fixing Chrome Plated (C.P) flush cock of approved brand as directed and specified (G.I & C.P pipes will be measured and paid separately) (I) Agmeco brand a) Flush cock Economy Cat No.00506
Supplying fitting and fixing chrome plated (C.P) wall mixer complete as directed. (ii) Agmeco brand a) Wall mixer non telephonic Cat No.00211
Supplying fitting and fixing pipes with all necessary fittings in exposed or in trenches or in trenches including trenches and refilling the same etc complete as directed. B) uPC pipe with uPC fittings (Using high pressure pipe) vii) 65mm diameter.
Supplying fitting and fixing pipes with all necessary fittings in exposed or in trenches or in trenches including trenches and refilling the same etc complete as directed. B) uPC pipe with uPC fittings (Using high pressure pipe) x) 110mm diameter.
(C) Construction of Approach Road: Clearing and grubbing road land including up rooting rank vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials & stacking of serviceable materials to be used or auctioned, upto a lead of 1000 m including removal & disposal of top organic soil not exceeding 150 mm in thickness as per MORTH specification 201. i) By Manual Means. (A) In area of non thorny jungle.
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1 (i) Private Land.
Construction of granular sub-base by providing well graded material spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at omc, and compacting with smooth wheel roller to achieve the desired density complete as per clause Technical specification clause 401. (ii) For Grading II Material.
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. By Manual Means
Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per technical specification Clause 1504 a) Including Edge restraint and carriage.
Earth work in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (a) In ordinary soil
Providing brick work soiling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a) Brick on flat soling.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1:3:6 (1 cement: 3 coarse sand. 6 coarse agg. by volume (Using mixture machine)
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks,supprots,chairs,spacers etc complete.(upto 1st floor level) b) Other ISI approved TMT reinforced bar (SAI/BISCON/THERMAX)
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc hight of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.1. Colums, pillars, posts & strut of square/rectangular/polygonal in plan or any shape like Tee/L etc.having plane vertical face.
Providing and laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding coast of from work and reinforcement for reinforce cement concrete work. (from work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (A) In Sub-Structure up to plinth level Foundation, footing, colums with base, tie & plinth beam, pile cap, base slab, retaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level. N) Without admixture, plasticiser b) M20 grade concrete ro prop 1:1.5:3
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-Structure upto plinth level including dewatering if necessary (b) In proportion 1:4
15mm thick cement plaster in single coat on rough side of single half brick wall for interior plastering upto 1st floor level including arrises, internal round angle not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. A) On rough side (b) In cement mortar 1:4 (1 cement: 4 sand)
(D) Construction of Garrage (4 Unit): Earthwork in excavation for foundation trenches of walls, retaining walls, footing of column, steps, septic tank etc. including refiling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead & lift as directed and specified in following classification of soils including bailing out water where necessary as directed and spedified. (A) Up to depth of 2.0 m below the existing Ground Level (a) In Ordinary Soil.
Providing brick soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a) Brick on flat soling.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop. 1:3: 6 (1 cement: 3 coarse sand : 6 coarse agg. by volume (using mixture machine)
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor level). a) From Primary Producer: TATA/SAIL/Esser Steel/Jindal Steel/Shyam Steel/RINL (i) TMT Corrosion resistant steel (CRS) reinforcement bar.
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc. hight of proping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in: 3.1.1.1. Foundation, footing, base of colums, pile cap, raft and mass concrete works etc. (i) Using 25mm thick plank
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc. hight of proping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in: 3.1.1.2. Sides of tie beams, plinth beams, grade beams etc. at or below ground level. (ii) Using 25mm thick plank.
Providing form work of ordinary timber planking so as to give a rough finish including centering,shuttering, strutting and proping etc hight of proping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.1. Colums, pillars, posts & strut Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face
Providing and laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding coast of from work and reinforcement for reinforce cement concrete work. (from work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (A) In Sub-Structure up to plinth level Foundation, footing, colums with base, tie & plinth beam, pile cap, base slab,retaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level. N. With out admixture, plasticiser (b) M20 Grade Concrete or prop 1:1.5:3
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-Structure upto plinth level including dewatering if necessary (b) In proportion 1:4
Earth/Sand filling in plinth in layer not more than 150mm thick including necessary,carriage,watering,raming etc.complete as directed and specified including payment of land compensation, Forest Royalty, Sales Tax and other duties and taxes may be necessary. (C) With Silt (predominently non plastic) by truck carriage including loading and unloading.
Providing and laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding coast of from work and reinforcement for reinforce cement concrete work. (from work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (B) In Sub-Structure from plinth level upto 1st floor level. (ii) Colums, pillars, posts, struts, suspended floor, roof landing , shelf & support balcony, lintel,sill band,beam,girder,bressumer,cantilever, stair case (except spiral stair case and landing) including preparing the top surface & finishing of nosing. N) With out using admixture plasticiser b) M20 grade concrete or Prop 1:1.5:3
Providing and laying 25mm thick damp proof coarse with cement concrete in prop 1:1.5:3 with graded store agg. Stone of 10mm down nominal size including providing approved damp proof admixture in proparation of recommended by the manufacturer including curing etc.complete as directed.
112mm thick 1st class brick nogged wall in cement morter including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) A) 112mm thick btick wall b) In cement mortar in proporation 1:4 (1 cement: 4 sand)
Providing fitting, hoisting and fixing of roof trusses including purlins fabricated out of M.S. black tube conforming to relevent I.S. code, as per approved and drawings including providing M.S. cleats, platesbolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paintscomplete including fitting necessary clear etc.for fixing joists as per design and drawings as directed. (b) Using other ISI marked approved circular hollow section
Providing Bare Galvalume Sheet Roofing at all levels including fitting and fixing self drilling self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately) TATA Blue scope/Dyna roof/Durakolor/Wonder Roof or eqivalent as directed by the Department. iv) 0.60mm thick
15mm thick cement plaster in single coat on rough side of single half brick wall for interior plastering upto 1st floor level including arrises, internal round angle not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. B) On rough side (b) In cement mortar 1:4 (1 Cement : 4 sand)
Cement plaster skirting with cement mortar in prop 1:3 (1 cement : 3 coarse sand) finished with a floating coat neat cement including rounding of junctions with floor. (a) 15mm thick.
65mm thick cement concrete floor consisting of 50mm under layer of cement concrete 1:3:6 of size (1 cement 3 coarse sand 6 coarse agg. Of size 25mm diwn) and 15mm thick wearing layer in cement concrete 1:1:2 (1 cement : coarse sand : 2 coarse agg of size 10mm down) laid in panels and finished with a floating coat of neat cement finish (using cement slurry for boad @ 2.75Kg per sqm of floor area) including curring etc.complete as directed.
Providing surface preparation for walls, ceilling etc, using average 1.50mm thick plaster of paries of pares including rubbing with sand paper filling gaps, depression etc. where necessary with chalk powder and plaster of pairs paste making the surface even and smooth complete at all levesl as specified and directed.
(a) Clour washing with lime on wall surface (two coats) over and including a priming coat of white washing to give an even shade after thouroughly brooming the surface to remove all dirt, dust mortar drops and other foreign matter.
Providing plinth protection with bricks flat laid in cement mortar 1:4 and finished with 15mm thick cement plaster in prop 1:2 with a floating coat of neat cement finish.
Providing drain with brick work in cement mortar in prop 1:5 with half brick thick side walls and 100mm thick CC (1:3:6) base over one brick flat soiling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shettering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. (ii) 300 wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
(E) Campus Filling by Raising Low Site: Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary land compensation, Municipal gate fees if any monopoly duty etc. (profile meassurement to be taken and 12.5% deduction for shrinkage to be made from total quantuty) etc. complete as per directed and specified, including forest royalty within a distance of 8.00 km. (forest royalty shall be reimbursed on production of necessary certificate from the forest authority duly countersigned by D.F.O. concerned.
(F) Construction of Iron Gate: Supplying fitting and fixing double leaf heavy duty iron gate frame made from 50mm x 6mm M.S flat iron with another horizontal flat at the middle, 20mm dia M.S bars at 200mm apart from bottom flat to top and 20mm dia M.S bars 200mm apart from bottom flat to middle flat including drilling welding etc. complete.
(G) Electrification Ground Floor: Wiring for light /fan/call bell point with 2x1.5 sq.mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR Conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) in surface/recessed conduit wiring system with 20mm dia thick/heavy right PVC IS:9537 Part-III conduit (Berlia/AKG/Precision/Presto plast/Polycab/MW or equivalent make as approvedc by the Deptt.) including 6 Amp flush type switch/bell push (Anchor penta/Gold medal/Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) Gi/MS switch board (ISI marked) with phenolic laminated sheet cover ceilling rose (Anchor penta/Gold medal /Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete 2.1.1 Short point up to 3.00 metre.length.
Wiring for light /fan/call bell point with 2x1.5 sq.mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR Conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) in surface/recessed conduit wiring system with 20mm dia thick/heavy right PVC IS:9537 Part-III conduit (Berlia/AKG/Precision/Presto plast/Polycab/MW or equivalent make as approvedc by the Deptt.) including 6 Amp flush type switch/bell push (Anchor penta/Gold medal/Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) Gi/MS switch board (ISI marked) with phenolic laminated sheet cover ceilling rose (Anchor penta/Gold medal /Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete 2.1.2 Medium point up to 6.00 metre.length.
Wiring for light /fan/call bell point with 2x1.5 sq.mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR Conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) in surface/recessed conduit wiring system with 20mm dia thick/heavy right PVC IS:9537 Part-III conduit (Berlia/AKG/Precision/Presto plast/Polycab/MW or equivalent make as approvedc by the Deptt.) including 6 Amp flush type switch/bell push (Anchor penta/Gold medal/Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) Gi/MS switch board (ISI marked) with phenolic laminated sheet cover ceilling rose (Anchor penta/Gold medal /Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete 2.1.3 Long point up to 10.00 metre.length.
Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt./ Havells make), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) 2.4.1 Extra long point up to 15.00 metre. length.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR cabel or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) including earth continuity in surface/recessed 20mm dia 2mm thick/heavy ISI marked IS:9537 PART-III rigid PVC conduit wiring system. 2.7.1 With 2 x 2.5 sq.mm. + earth continuity with 1 x 1.5 sq.mm in 20mm. dia.2mm thick/heavy rigid PVC IS:9537 Part-III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR cabel or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) including earth continuity in surface/recessed 20mm dia 2mm thick/heavy ISI marked IS:9537 PART-III rigid PVC conduit wiring system. 2.7.3 With 2 x 6 sq. mm. + earth continuity with 1x4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS:9537 Part - III conduit.
Wiring for 5 pin 6 Amp plug point with 1.5 sq.mm PVC insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 volts with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR cabel or Equivalent Make as approved by the Deptt.) including providing and fixing 5 pin 6 Amp socket outlet (Anchor penta/Gold medal/Kolor Kany. Kom/Havells or equivalent make as approved by the deptt.)make 6 amp flush type switch (Anchor penta/Gold medal/Kolor kany.Kom/Havells or equivalent make as approved by the deptt.) make) earthing the 3rd pin of the socket as required on the switch board surface/recessed PVC conduit wiring system. when fitted on same board of light and fan.
Supplying and fixing of batten holder including 11 W CFL lamp and connection as approved by the Deptt. as required.
Supplying with fitting and fixing sheet steel phosphatised powder painted single door surface mounting MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with groting nuts & bolts as reqd. complete with making necesssary connecting as approved specified and directed by the deptt. 15.1.1.1 4 way SPN double door
Supplying with fitting and fixing sheet steel phosphatised powder painted single door surface mounting MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with groting nuts & bolts as reqd. complete with making necesssary connecting as approved specified and directed by the deptt. 15.2.1.3 8 way SPN double door
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (Schneider MG, legrand, Hager make)
Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.3.2. C Series (ABB, Schneider MG, legrand, Hager make) 16.3.2.3 63A
Supplying with fitting and fixing panel mounting open execution 25KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.16.1 25 KA 415V 50 Hz 4P MCCB (Schneider, legrand, Siemens, Indo Asian make) 16.16.1.3 40A
Supplying with fitting and fixing panel mounting open execution 25KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.16.1 25 KA 415V 50 Hz 4P MCCB (Schneider, legrand, Siemens, Indo Asian make) 16.16.1.7 125A
Supplying including installation, commissioning of vermin and dust proof totally enclosed, Phosphatised powder painted cubical indoor type floor/wall mounting compartmentalize panel board of size 0.85M x 1.20 MX 0.40M made of 16 SWG 1.66 m thick C.R. sheet and 35mm X 35mm X 5mm size angle having 4 no legs at the bottom. The panel board is to be erected in 1:3:6 PCC foundation including brick soling/grounting etc. complete neatly wiring done with provision for one no 125/160A 4pole MCCB or Switch Fuse Unit as incomer and provision for 4nos DP or TPN out going as specified and directed by the deptt.confirming to IP 43 protection comprising of the following electrical items:
Supply installation & testing of G.I earth station with perforated 40 mm dia. and 4.50 mt. long head duty G.I pipe with necessary 40 mm dia. G.I. Fitting such as Socket, tee elbow, nipple and 50 mm x 40mm G.I reducing socket for funnel including breaking arrangement 300mm x 300mm x 6mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick copper and flustering of both inner of outer surface of wall as specified and directed by the deptt.
Extra for using salt (5 Kg. and Charcoal 64 Kg. in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.)
Supplying & laying of 8 SWG Copper. Earth from Earth Electrode (below G.L) to electrical switch gear or electrical machineries including making necessary connection as approved specified and directed by the deptt.
Supplying including fitting fixing of following A.C. ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the as required complete and as directed by the Department ( Without requlator). 27.1.2 Premium model 1200 mm Sweep. (ORIENT PSPO make)/ Premium model 1050/1200mm Sweep SS-390 Deco. Havells make).
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.) as required complete and as directed by the Department. 27.2.1.2 Power Flow 225 mm sweep (ORIENT make)
Supplying fitting and fixing of ceiling fan regulator including connection etc. complete as regd. 27.6.2 Electronic type.
Supplying and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Soild Aluminium conductor XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm blance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm 4x6 sq mm balance all galvanised steel strip) extruded Type ST2 sheathed, 650/1100V grade as per IS 7908 (Part 1) 1988 armoured in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt.(Nicco/Havels/RPG/CCI/Polycab/Gloster/Finolex make). 32.1.1.3 10.00 sq.mm 2 Core armoured U.G.cable
Supplying and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Soild Aluminium conductor XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm blance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm 4x6 sq mm balance all galvanised steel strip) extruded Type ST2 sheathed, 650/1100V grade as per IS 7908 (Part 1) 1988 armoured in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt.(Nicco/Havels/RPG/CCI/Polycab/Gloster/Finolex make). 32.1.3.1 25.00 sq.mm 3 & 1/2 Core armoured U.G.cable
Supplying, installation, testing and commission of the following indoor CFL/Fluorescent luminaries complete with all accessories such as ballast, starter etc. directly on wall / ceilling including connection as approved by the Deptt.) with 1.5 sq mm P.V.C. insulated S.C. copper conductor as required and as directed by the department. ECBC 3.2.11 BATTEN LIGHT, TMS 020 1X T-5 28 W with 1x28 W T-5 Fluorescent tube, (philips make or equivalent)
Supplying with fitting and fixing of 120 watt electronic modular STEP speed control 2-module type MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE (MURANO) including making necessary connection as per direction of department. 120 watt electronic modular step speed control 2-module type.
Supplying with fitting of 6 amp one way modular clip in bell push MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE (MURANO) including making necessary connection as per direction of department.
Supplying with fitting fixing of 6 amp one way modular clip in bell push with LED, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including installation of socket outlet 10/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE (MURANO) including making necessary connection as per direction of department.
Supplying including installation of socket outlet 6/10 Amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE (MURANO) including making necessary connection as per direction of department.
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department. SB 8.13.2 3 module type Metal
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department. SB 8.13.4 6 module type Metal
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department. SB 8.13.5 8 module type Metal
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department. SB 8.13.7 12 module type Metal
Supplying including and fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department. SB 8.14.3 3 module
Supplying including and fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department. SB 8.14.5 6 module
Supplying including and fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department. SB 8.14.6 8 module
Supplying including and fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department. SB 8.14.8 12 module
Supplying and fitting fixing of Electric storage water heater (Geyser) of Bajaj/Crompton/Racold/V. Guard or equivalent make including necessary connection cable, as approved by the Deptt.) etc. as required complete and as directed by the Department. ECBC 2.1.4 (iv) 25.00 litres. Capacity (5 Star Model) (Crompton/Racold/V. Guard or equivalent make)
(G) Electrification First Floor: Wiring for light /fan/call bell point with 2x1.5 sq.mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR Conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) in surface/recessed conduit wiring system with 20mm dia thick/heavy right PVC IS:9537 Part-III conduit (Berlia/AKG/Precision/Presto plast/Polycab/MW or equivalent make as approvedc by the Deptt.) including 6 Amp flush type switch/bell push (Anchor penta/Gold medal/Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) Gi/MS switch board (ISI marked) with phenolic laminated sheet cover ceilling rose (Anchor penta/Gold medal /Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete 2.1.1 Short point up to 3.00 metre.length.
Wiring for light /fan/call bell point with 2x1.5 sq.mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR Conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) in surface/recessed conduit wiring system with 20mm dia thick/heavy right PVC IS:9537 Part-III conduit (Berlia/AKG/Precision/Presto plast/Polycab/MW or equivalent make as approvedc by the Deptt.) including 6 Amp flush type switch/bell push (Anchor penta/Gold medal/Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) Gi/MS switch board (ISI marked) with phenolic laminated sheet cover ceilling rose (Anchor penta/Gold medal /Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete 2.1.2 Medium point up to 6.00 metre.length.
Wiring for light /fan/call bell point with 2x1.5 sq.mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR Conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) in surface/recessed conduit wiring system with 20mm dia thick/heavy right PVC IS:9537 Part-III conduit (Berlia/AKG/Precision/Presto plast/Polycab/MW or equivalent make as approvedc by the Deptt.) including 6 Amp flush type switch/bell push (Anchor penta/Gold medal/Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) Gi/MS switch board (ISI marked) with phenolic laminated sheet cover ceilling rose (Anchor penta/Gold medal /Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete 2.1.3 Long point up to 10.00 metre.length.
Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt./ Havells make), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) 2.4.1 Extra long point up to 15.00 metre. length.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR cabel or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) including earth continuity in surface/recessed 20mm dia 2mm thick/heavy ISI marked IS:9537 PART-III rigid PVC conduit wiring system. 2.7.1 With 2 x 2.5 sq.mm. + earth continuity with 1 x 1.5 sq.mm in 20mm. dia.2mm thick/heavy rigid PVC IS:9537 Part-III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR cabel or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) including earth continuity in surface/recessed 20mm dia 2mm thick/heavy ISI marked IS:9537 PART-III rigid PVC conduit wiring system. 2.7.3 With 2 x 6 sq. mm. + earth continuity with 1x4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS:9537 Part - III conduit.
Wiring for 5 pin 6 Amp plug point with 1.5 sq.mm PVC insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 volts with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR cabel or Equivalent Make as approved by the Deptt.) including providing and fixing 5 pin 6 Amp socket outlet (Anchor penta/Gold medal/Kolor Kany. Kom/Havells or equivalent make as approved by the deptt.)make 6 amp flush type switch (Anchor penta/Gold medal/Kolor kany.Kom/Havells or equivalent make as approved by the deptt.) make) earthing the 3rd pin of the socket as required on the switch board surface/recessed PVC conduit wiring system. when fitted on same board of light and fan.
Supplying and fixing of batten holder including 11 W CFL lamp and connection as approved by the Deptt. as required.
Supplying with fitting and fixing sheet steel phosphatised powder painted single door surface mounting MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with groting nuts & bolts as reqd. complete with making necesssary connecting as approved specified and directed by the deptt. 15.1.1.1 4 way SPN double door
Supplying with fitting and fixing sheet steel phosphatised powder painted single door surface mounting MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with groting nuts & bolts as reqd. complete with making necesssary connecting as approved specified and directed by the deptt. 15.2.1.3 8 way SPN double door
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (Schneider MG, legrand, Hager make)
Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.3.2. C Series (ABB, Schneider MG, legrand, Hager make) 16.3.2.3 63A
Supply installation & testing of G.I earth station with perforated 40 mm dia. and 4.50 mt. long head duty G.I pipe with necessary 40 mm dia. G.I. Fitting such as Socket, tee elbow, nipple and 50 mm x 40mm G.I reducing socket for funnel including breaking arrangement 300mm x 300mm x 6mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick copper and flustering of both inner of outer surface of wall as specified and directed by the deptt.
Extra for using salt (5 Kg. and Charcoal 64 Kg. in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.)
Supplying & laying of 8 SWG Copper. Earth from Earth Electrode (below G.L) to electrical switch gear or electrical machineries including making necessary connection as approved specified and directed by the deptt.
Supplying including fitting fixing of following A.C. ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the as required complete and as directed by the Department ( Without requlator). 27.1.2 Premium model 1200 mm Sweep. (ORIENT PSPO make)/ Premium model 1050/1200mm Sweep SS-390 Deco. Havells make).
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.) as required complete and as directed by the Department. 27.2.1.2 Power Flow 225 mm sweep (ORIENT make)
Supplying fitting and fixing of ceiling fan regulator including connection etc. complete as regd. 27.6.2 Electronic type.
Supplying, installation, testing and commission of the following indoor CFL/Fluorescent luminaries complete with all accessories such as ballast, starter etc. directly on wall / ceilling including connection as approved by the Deptt.) with 1.5 sq mm P.V.C. insulated S.C. copper conductor as required and as directed by the department. ECBC 3.2.11 BATTEN LIGHT, TMS 020 1X T-5 28 W with 1x28 W T-5 Fluorescent tube, (philips make or equivalent)
Supplying with fitting and fixing of 120 watt electronic modular STEP speed control 2-module type MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE (MURANO) including making necessary connection as per direction of department. 120 watt electronic modular step speed control 2-module type.
Supplying with fitting of 6 amp one way modular clip in bell push MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE (MURANO) including making necessary connection as per direction of department.
Supplying with fitting fixing of 6 amp one way modular clip in bell push with LED, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including installation of socket outlet 6/10 Amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE (MURANO) including making necessary connection as per direction of department.
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department. SB 8.13.2 3 module type Metal
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department. SB 8.13.4 6 module type Metal
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department. SB 8.13.5 8 module type Metal
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department. SB 8.13.7 12 module type Metal
Supplying including and fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department. SB 8.14.3 3 module
Supplying including and fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department. SB 8.14.5 6 module
Supplying including and fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department. SB 8.14.6 8 module
Supplying including and fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department. SB 8.14.8 12 module
Supplying and fitting fixing of Electric storage water heater (Geyser) of Bajaj/Crompton/Racold/V. Guard or equivalent make including necessary connection cable, as approved by the Deptt.) etc. as required complete and as directed by the Department. ECBC 2.1.4 (iv) 25.00 litres. Capacity (5 Star Model) (Crompton/Racold/V. Guard or equivalent make)
Supplying & laying of following size Copper strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of Brass nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.
Supply, fitting & fixing 20 mm x 3 mm copper strips drawn on vertically or horizontally on building wall/parapet wall in surface system complete with supply of Brass Nuts & Bolts, Screws etc including riveting, soldering and making connection as approved by the Deptt.) with earth electrode copper strips and Lightning Arrestor etc. as specified and directed by the deptt.
KEMENDRA KUMAR BRAHMA
Bakul Chandra Brahma
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .