| 1.00 | Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out any type of soil. | 150 | Sqm | 60 ₹9,000 | 25 ₹3,750 Lowest | 250 ₹37,500 | 50 ₹7,500 |
| 2.00 | Excavation in trenches n exc 1.5m wide and n exc 1.5m in depth, for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc n exc10 sqm on plan and n exc 1.5m in depth and getting out any type of soil. | 53.76 | Cum | 200 ₹10,752 Lowest | 250 ₹13,440 | 450 ₹24,192 | 200 ₹10,752 Lowest |
| 3.00 | M&L PCC 1:4:8 type D2 (using 40mm graded stone aggregate)as in foundation , filling and mass concrete complete all as specified and directed. | 4 | Cum | 3,000 ₹12,000 | 3,000 ₹12,000 | 3,000 ₹12,000 | 2,500 ₹10,000 Lowest |
| 4.00 | M & L brick work with sub class 'B' old size bricks straight or curved on plan exc.6m mean radius built in cm 1:6 | 40 | Cum | 8,000 ₹3,20,000 | 7,000 ₹2,80,000 | 7,000 ₹2,80,000 | 6,200 ₹2,48,000 Lowest |
| 5.00 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in any type of soil. | 29.26 | Cum | 70 ₹2,048.2 | 50 ₹1,463 Lowest | 50 ₹1,463 Lowest | 100 ₹2,926 |
| 6.00 | Removing excavated material n. exc 50m & depositing where directed at a level n.exc.1.5m above the starting point. | 44.5 | Cum | 70 ₹3,115 | 50 ₹2,225 Lowest | 50 ₹2,225 Lowest | 100 ₹4,450 |
| 7.00 | Supply only integral waterproofing compound complete all as specified and directed. | 1 | Litre | 200 ₹200 | 50 ₹50 Lowest | 250 ₹250 | 70 ₹70 |
| 8.00 | M & L for providing reinforced cement concrete M- 25 (Design Mix), using 20 mm graded stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete all as specified and directed. | 12 | Cum | 7,200 ₹86,400 | 7,000 ₹84,000 | 7,800 ₹93,600 | 6,900 ₹82,800 Lowest |
| 9.00 | M & L for providing reinforced cement concrete M- 25 (Design Mix), using 20 mm graded stone aggregate as in columns, pillars, piers, posts and struts all as specified and directed. | 6 | Cum | 7,200 ₹43,200 | 7,000 ₹42,000 | 8,400 ₹50,400 | 6,900 ₹41,400 Lowest |
| 10.00 | M & L for providing reinforced cement concrete M- 25 (Design Mix), using 20 mm graded stone aggregate as in lintels all as specified and directed. | 1.2 | Cum | 7,200 ₹8,640 | 7,000 ₹8,400 | 8,400 ₹10,080 | 6,900 ₹8,280 Lowest |
Tender Value
₹31.7 L
EMD Value
₹63,500
Closing Date
19 May 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Army Dhar Road
GE Army Dhar Road
PROVN OF 02 X FOL DUMP STORE TOP AND BASE AT 3T WE DET SAMNABANJ OF 18 WEU UNDER GE ARMY DHAR ROAD UDHAMPUR. JOB NO 18 WEU LBW-02 24-25
2025_MES_704772_1
8071/NIT-02/2025-26
Open Tender
Civil Works
Item Rate
270 days
GE Army Dhar Road
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE Army Dhar Road
₹63,500
Yes
8 Aug 2025
19 Apr 2025
21 May 2025
20 Apr 2025
19 May 2025
5 May 2025
Amount
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out any type of soil.
Excavation in trenches n exc 1.5m wide and n exc 1.5m in depth, for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc n exc10 sqm on plan and n exc 1.5m in depth and getting out any type of soil.
M&L PCC 1:4:8 type D2 (using 40mm graded stone aggregate)as in foundation , filling and mass concrete complete all as specified and directed.
M & L brick work with sub class 'B' old size bricks straight or curved on plan exc.6m mean radius built in cm 1:6
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in any type of soil.
Removing excavated material n. exc 50m & depositing where directed at a level n.exc.1.5m above the starting point.
Supply only integral waterproofing compound complete all as specified and directed.
M & L for providing reinforced cement concrete M- 25 (Design Mix), using 20 mm graded stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete all as specified and directed.
M & L for providing reinforced cement concrete M- 25 (Design Mix), using 20 mm graded stone aggregate as in columns, pillars, piers, posts and struts all as specified and directed.
M & L for providing reinforced cement concrete M- 25 (Design Mix), using 20 mm graded stone aggregate as in lintels all as specified and directed.
M & L for providing reinforced cement concrete M- 25 (Design Mix), using 20 mm graded stone aggregate as in chajjas all as specified and directed.
M & L for providing reinforced cement concrete M- 25 (Design Mix ) using 20 mm graded stone aggregate as in slab, etc all as specified and directed.
M & L TMT bars 10mm dia and over cut to length, bent to shape required incl. cranking, bending and incl. mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
M & L TMT bars 6mm to 8mm dia cut to length, bent to shape required incl. stirrups spacers and incl. mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
M & L for use and waste of form work to sides of concrete foundation, footing, bases of columns, raft & raft beams, sides and soffits (if any) of foundation and plinth beam and similar works in rough finished flat surface of concrete complete all as specified and directed.
M & L for use and waste of form work to sides of pillars, posts, struts, piers, columns and stanchions in rough finished surface, square or rectangular of concrete complete all as specified and directed.
M & L for use and waste of formwork to sides and soffits of floor, lintels band & beams including supports, overhangs, etc. with rough finished surface of concrete all as specified and directed.
M & L for use and waste of formwork to chajjas including edges with rough finished surface of concrete all as specified and directed.
M&L for Use and waste for form work to soffits of suspended concrete slabs for fair finished concrete surface flat surface complete all as specified and directed.
M&L for 15mm thick cement plaster in CM 1:6 on fair face of brick or concrete walls finished even and smooth without using extra cement complete all as specified
M&L for rendering 15 mm thick in CM 1:4 on other than fair faces of brick or concrete surfaces finishing even and smooth without using extra cement complete all as specified and as directed .
M&L for rendering 5 mm thick in CM 1:3 in ceiling / Chhajja's finished even and smooth (without using extra cement) complete all as specified and directed
M&L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over a coat of wall primer complete all as specified and directed
M&L for applying two coats of acrylic exterior emulsion paint (Apex) over a coat of primer incl over a coat of wall care putty after preparation of newly plastered/concrete surfaces on wall complete all as specified
M&L for prepration of new plastered surface and applying three coat of white wash on ceiling complete all as specified and as directed.
M & L broken stone or boulder hardcore of gauge n exc. 63 mm, deposited, spread and leveled in layers n exc. 15 cm thick, watered and rammed to a true surface.
M & L for 75 mm thick PCC (1:3:6) type C2 using 40mm graded stone aggregate as in plinth protection and foot path etc. finished even and smooth without using extra cement.
M & L 75mm thick PCC 1:4:8 type D-2 (40mm graded aggregate) in sub base complete all as specified and directed.
M&L for Machine cut Kota stone slab flooring 20-22 mm thick, laid over & including screed bed of 20 mm thick in cement mortar (1:4) and jointed with grey cement slurry mixed with matching shade pigment including rubbing and polishing (Granite finish) complete, all as specified.
M&L for Kota stone slab 20-22 cm thick on vertical surfaces like riser of steps, skirting, dado and pillar laid over & including 10 mm thick in cement mortar (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing (Granite finish), complete all as specified.
M&L for factory made pre-cast cement concrete block type B1, 1:2:4 as in kerb stone made to shape as directed, exc. 10 cm in width and setting in mortar 1:4, complete all as specified and as directed.
M&L for machine pressed precast concrete interlocking paver block of 80mm thickness any shape and size confirming to IS 15658 -2006, M-40 with grey cement and pigment incl 20mm thick fine sand as cushioning complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in mass concrete over roof slabs to level the surface including use of necessary form work complete all as specified and directed
M&L for preparation of plastered/concrete surfaces of roof and applying the under mentioned course of roof treatement complete all as specified and directed by Engineer-in-Charge.:- (a) Plastering 10mm thick in cement mortar 1:4 on concrete surfaces using WPC @3% by weight of cement, finished even and smooth (b) Surface shall be throughly wire brushed, cleaned, washed, dried up properly and apply evenly a bituminuous primer coat conforming to IS @0.4 ltr /Sqm over concrete / plastered roof surface. (c) Laying of 3mm thick APP membrane sheet (min weight 3 Kg/Sqm) consisting of a core of 160 gms/Sqm polyster non woven fabric mat protected on both sides with a high quality polymeric asphaltic mix again protected with thermo fusible HMHDPE FILM on dried primed surface by torch application method. APP membrane will normally be laid in length at right angle to the direction of slope. The over lap shall be minimum 100mm on longitudinal direction and 150mm on the transverse direction including cuttings, grooves etc. (d) Membrane bonded completely to the substrate & the over laps are then scaled/fused by flame.
M&L Cement concrete type B1 1:2:4 (20 mm graded stone aggregate) as in seismic and other similar bands, plinth courses, string courses, lacing courses, , copings, kneelers, apex stones, bed plates, kerbs water troughs and the like including weathering, slightly rounded or chamfered angles and throating as directed
Excavation in post holes n.exc 0.5 cum getting out, returing and filling in & raming earth or broken rubble mixed with earth around, in layers n.exc 25CM, watering and removing surplus soil to a distance n.exc 50m and making good surface complete all as specified and directed in any type of soil
M&L for cement concrete of type D2 (1:4:8) using 40mm graded agg in foundation filling and mass complete all as specified as directed.
S&F post and struts in fencing including cutting tops to shape as directed, drilling holes notching for wire, etc. flat iron fillets ( for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc. and similar work conforming to Fe-290 Gde E-165 Complete all as specified and directed.
S&F mild steel screw bolts (machine made ) 65mm long, 12mmm dia with hexagonal or sqsuare head at one end and screw the other, or screwed bolt ends, each screw end to be fitted with washer and one hexagonal or square nut, exc 5cm but n.exc 10cm long.
Supply only Chain link MS galvanised fencing, any size or type complete all as specified and directed.
Fixing only chain link fencing including line wire, any mesh, size and type to any type of standards, rails, straining bolts, etc including provission of binding wire. Complete all as specified and directed.
M&L for preparation of new steel or iron surfaces of any description not otherwise described over 10 cm girth or width and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as directed and specified.
M & L for on surface Flame proof point wiring for One light /Fan/Bell point controlled one flame proof switch 5/6 Amp one way single pole, on wall and ceiling/ roof with necessary fixing arrangements with PVC insulated FRLS and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid stove enameled steel metallic conduit not less than 20 mm dia including all MS conduit accessories/ fittings except flame proof bends, tees,junction boxes but including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.2 mm for fixing of switches / sockets, fittings,etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surfaces by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour complete all as specified and as directed by Engineer-in-Charge.
M & L for on surface Flame proof point wiring for controlled one flame proof switch 15/16 Amp one way single pole, on wall and ceiling/ roof with necessary fixing arrangements with PVC insulated FRLS and unsheathed copper multi-stranded conductor of size 2.5 Sqmm, 1100 volts grade drawn in and including rigid stove enameled steel metallic conduit not less than 25 mm dia including all MS conduit accessories/ fittings except flame proof bends, tees,junction boxes but including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.2 mm for fixing of switches / sockets, fittings,etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surfaces by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing flame proof LED light fitting not less than 16 Watt , CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable in flexible metalic conduit from fitting to junction box with suitable size complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing flame proof Cum Waterproof LED BulkHead light fitting not less than 15 Watt , CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 66 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable in flexible metalic conduit from fitting to junction box with suitable size complete all as specified and as directed by Engineer-in-Charge.
S&F switch flameproof rotary type with termination box in LM6,6/16 Amp single pole, 240 Volts complete all as specified and as directed by Engineer-in-Charge
Supply and fixing switch socket & plug combined In LM6 Cable ternimation Box In LM6,16 Amp,240V,complete all as specified and directed by Engr-Incharge.
S&F submain wiring alongwith earth wire with 2x4.0 sq. mm + 1x4 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed alonwith rigid steel conduit 20 mm dia complete all as specified and as directed by Engineer-in-Charge.
Supply & Fixing MCB SPN, 5 to 40 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and as directed by Engineer-in-Charge.
Supply & Fixing MCB SP, 06 to 40 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and as directed by Engineer-in-Charge.
Supply & Fixing V TPN Distribution with and including 125 amp MCCB 4 pole 25 KA, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 04way, confirming to IS 13032 & 8623 complete all as specified and directed.
supply & fixing flame proof junction box 3 way made of stainless steel anti corrosive epoxy powder coated of size 100mm x50 mm IP 65 ,IS:2148-2004,Class T-6, complete all as specified and directed by Engineer-in-Charge
supply & fixing flame proof bend 20 mm dia IP 65 ,IS:2148-2004,Class T-6,complete all as specified and directed by Engineer-in-Charge
supply and laying XLPE cable 35 x 3.5 core complete all as specified and directed by Engineer incharge
Material and labour for sand cushioning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable to trenches and punning down complete all as specified and directed by Engineer-in-Charge.
Material and labour cover to underground cable with one layer of bricks using sub class 'B' bricks laid flat acorss the cable complete all as specified and directed by Engineer-in-Charge.
M&L for earthing as per IS:3043 with galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4 mm dia (8 SWG) as earthing lead protected by GI pipe medium grade 15 mm bore for protection of GI earth wire and 20 mm dia GI pipe medium grade for watering with alternate layers of charcoal /coke and salt including all accessories like nut, bolts, reducer, nipple, wire meshed/screened funnel and making brick masonry finished chamber of internal size 300 mm x 300 mm x 300 mm with concrete base, covered with PCC cover which shall be embedded in the block masonry including excavation works, refilling, connected to main switch/MCB DB for feeding the electric supply to domestic quarters compete all as specified as shown in electricall plateNo. 3 of SSR Part-I and testing of earth resistance as required. Note : Earthing lead/G.I.Earth wire upto 7.5 metre length shall be deemed to be included in quoted unit rate beyond 7.5 metre, the same shall be measured and paid separately).
Chemical Earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick buried in ground vertically to a depth not less than 2.25 mm below ground level with top edge of the earth plate not less than 1.5 mm below normal ground level, connected to copper strip 20 x 3 mm continuity conductor including 40 mm bore pipe light grade for protection of strip by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel connected to earth test point upto 7.5 mt away from earth electrode all as shown as per plate No 03 of SSR I including necessary earth work, PCC 1:3:6 type C 1 chamber, RCC cover slab of 50 mm thick 1::2:4 with 8 mm CTD 140 mm C/C with suitable handle,watering pipe 40 mm dia light grade pipe with funnel,. charcoal salt and testing on completion all as specified and directed
S & F air termination single pointed aluminium rod 12 mm dia and 300 mm longlightening conductor tube 40 mm on buildings with F clamps nut bolts complete all as specified and directed.
S & F earth test point terminal block made out of gun metal or phorphorus bronze size not less than 70 mm x 70mm x 5mm , drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screw grouting on wall with PCC, nut bolts and washers, including making good to disturbed surface complete all as specified and directed.
S&F copper strip 20 x 3 mm for extension of earth and connected to equipment or panel complete all as specified and as directed .
S&F GI tubing light grade 40 mm bore fixing including grouting in PCC complete all as specified and directed for fixing leghtening arrester on roof top.
Deduct Schedule of Credit of Rs. (-) 0.00 (Minus) as listed in Schedule 'A' Part-II. Contract Sum shall be arrived after deducting the credit amount Note: Tenderers will not quote against this item being a firm amount.
jyoti parkash sharma (BID ID -3295614)
M/s Ranpat Dev Infrastructure pvt ltd (BID ID -3300295)
s l sharma and sons (BID ID -3299849)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .