Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.1 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹28.7 L+₹74,910.90 (2.68%)Rejected-Finance 64 250 2 COD ROAD HASTINAPURI MADHU NAGAR AGRA 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹33.1 L+₹5.2 L (18.4%)Rejected-Finance HNO 52B LAXMI PLACE PHASE II DEORI ROAD NEAR MOHANDEV SCHOOL UKHARA ROAD AGRA 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹33.6 L+₹5.6 L (19.9%)Rejected-Finance 86 NAROTTAM KUNJ MADHU NAGAR AGRA UTTAR PRADESH 282001 | AGRA | UTTAR PRADESH | 282001 | L4 | Rejected-Finance Other than L1 |
Tender Value
₹30.8 L
EMD Value
₹61,560
Closing Date
5 Apr 2021, 6:00 pmClosed
GE EAST AGRA
Garrison Engineer East Agra, Gwalior House, 62 Taj Road Agra Cantt
SPECIAL REPAIR OF BUILDING NO P22 ARCC GP WLR SEC AT 509 ABW UNDER GE EAST AGRA
2021_MES_426436_1
9336/E8
Open Tender
Civil Works
Item Rate
180 days
AGRA
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE EAST AGRA
₹61,560
Yes
20 Apr 2021
27 Feb 2021
12 Apr 2021
27 Feb 2021
5 Apr 2021
15 Mar 2021
Amount
Dismantling asbestos cement (corrugated, semicorrugated sheet/ North light curve, Ridge etc.) sheets in roof coverings complete all as specified and directed.
S&F of Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed.
S&F of Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed.
S&F in repair 1.25mm thickness plain, galvanised, mild steel sheeting, in ridges, hips, vally gutters, drip and straight flashing (length and girth as fised) with grade of zinc coating 275 cut, bent to slope as required as per site requirement for vally gutter welded or soldered joints and fitted to steel member for smooth flow af water etc including taking down old vally gutters, taking down and refixing AC sheets required for fixing of the vally gutter, filling all holes and making good the disturbed portion complete all as specified and directed by Engineer-in-charge.
M&L for drop ends (for spigot or socket ends) or nozzles in valley gutters for thickness of sheet 1.25mm and dia 125mm complete.
Demolition of Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L PCC 1:2:4 type B-0( using 12.5mm stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
Taking down cement plaster on brick or stone walls including racking out joints, hacking for key, scrubbing down with water etc.complete all as specified and directed.
Demolition of brick work built in cement mortar including all quoins arches pillar etc complete all as specified and directed.
M&L for brick work with subclass B bricks old size straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L, rendering 15 mm thick in CM 1:4 on fair faces of brick work or concrete surface and finishing surface fair and even complete all as specified and directed.
M&L for preparing newly plastered surfaces of wall and applying two coats of cement base paint complete all as specified and directed.
Material & labour for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM (1:6) surfaces finished even and fair faces complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of OBD on newly plastered surfaces complete all as specified and directed.
Dismantling wall and ceiling board or insulation board /slabs/blanket any thickness including cover fillets.
S&F in repairs 605x605mm snap grid of powder coated galvanized iron of angle of size 23mm x 23mm of 30 gauge (Perimeter), T section of size 23mm x27mm and main T 23mm x 35 mm of 30 gauge suitable for false ceiling including GI wire 3 mm thick @ 1200 mm centre to ceter both ways for hanging arragement coplete all as specified and directed
M&L for 4 mm thick non asbestos fibre cement building designer boards fixed in ceiling or laid/inserted to timber/GI/aluminun frame.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning for issue under schedule of credit measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed by the Engineer-in-charge.
S & F of PVC(SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall (200 mm bore ) complete all as specified and directed.
S&F of PVC (SWR) water bends any radius 200 mm dia complete all as speified and directed
Dismantling of wrought iron of mild steel work of any description not otherwise poivided
S&F of framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290. Gde-E-165 complete all as specified and directed.
M&L Preparation of old steel surfaces of any description over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint complete all as specified and directed
M&L Preparation of new steel surfaces of any description over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed
Taking down chowkats or frame with shutter (without taking off shutters from the frame) exc 1.5 Sqm and not exc 4.00 Sqm each complete all as specified and directed.
Taking down chowkats or frame with shutter (without taking off shutters from the frame) not exc 1.5 Sqm each complete all as specified and directed.
M&L for factory made Pressed steel frames 125 x 60 x 1.25mm thick for doors with one or more rebates including necessary fixing lugs, hinges, lock, strike plate,etc complete including PCC (1:3:6) type C-0 (using 12.5 mm graded stone aggregate) as in filling hollow portion of frame complete all as specified and directed.
S & F Second class hardwood factory made door 35mm thick plain framed, panelled shutter (Two pane) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS 1003 (Part I) klin seasoned and chemically pressure treated complete all as specified and directed.
S & F 300 mm mild steel sliding bolt, bolt type stove enamelled black with bright bolt not less than 12 mm dia with and including a minium of 6 bolts and nuts four on bolt plate and two on stapple plate and fixed complete all as specified and directed.
M&L for mild steel barrel tower bolt stove enamelled black with bright bolt and fixed 200mm size . complete all as specified and directed.
M&L for mild steel pressed handle oval type stove enamelled black 150mm size .complete all as specified and directed.
S & F floor door stopper of aluminium alloy body and tongue, anodised,with hard drawn steel spring, fixed in floor complete all as specified and directed.
Taking down mechinical/ hand operated rolling shutters of size n. exc 10 sqm each completed all as specified and directed
S&F of Steel rolling shutters 1.00 mm thick laths, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, gear operated type with chain wheel and hand chain complete all as specified and directed.
M & L for preparation of new steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint complete all as specified and directed.
S&F of Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified
S&F aluminium anodised grill (DG 104) 10mm x 5.2mm thick on Deco grill or equivalent fixed with 'F' section approved make complete all as specified and directed.
S & F galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks or galvanized wire staples complete all as specified and directed
M&L for Providing precast cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone wallin). corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in mortar complete with joints to match set in cement mortar 1:4 complete all as specified and directed.
M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and direted.
Hacking out old broken glass (any thickness, size quality or description) from wooden or metal frames, glazed with putty or fixed with beads etc complete all as specified & as directed.
S&F of sheet glass 4.80mm thick ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane complete all as specified and directed.
M&L for preparing old plastered surfaces of wall and applying two coats of cement base paint complete all as specified and directed.
M&L for preparing old plastered surfaces of wall and applying two coats of oil bound distemper complete all as specified and directed.
M&L for preparing old plastered surfaces of wall and applying two coats of white wash complete all as specified and directed.
Taking down carefully aluminum/copper point wiring (light fan socket or power) complete , including fixutre and fittings such as switches, sockets, regulators, lamp holders, luminaries, ceiling roses complete and making good disturbed surfaces of walls, floor to match with existing specification complete and all as specified and removing from site.
M&L point wiring with 1.5 sqmm multi stranded copper conductor 1100 volts. grade FR PVC insulated unsheathed cable with proper colour coding drawn in including PVC concealed conduit not less than 20 mm dia with all accessories and FR PVC insulated 1.5 Sqmm multi standard sheathed copper wire for continues earth, sunk in cast iron/Pressed steel terminal boxes 60 mm deep & 1.6 mm thick duly painted with aluminum inside and anticorrosive paint out side/PVC polycarbonate PVC rectangular block 50 mm deep, including 3 mm thick plastic laminated sheet for mounting switches, sockets, fan regulators etc connecting earth and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCB's or bus bar shall be done through proper size copper/brass thimbles. Make Polycab/Finolex/RR Kablel/Grandlay. Note :Conduit shall be fixed on surface of roof with necessary saddles where concealing of conduit is not feasible at no extra cost for the following :- (a) One light /fan point controlled by one switch
One 5 pin socket outlet 5 Amps on independent board
One 5 pin socket outlet 5 Amps on same board
All as per item No 47.00 above but with 2.5 sqmm multi stranded copper conductor 1100 volts grade FR PVC insulated sheathed cable with FR PVC 2.5 Sqmm multi standard insulated unsheathed copper wire for continues earth on independent board/600 sqmm wall fan.
Supply and fix switch piano flush button single pole one way 5 amps 240 volts with polycarbonate body all as specified and directed. Make : SSK Top Line/Legrand/Havells
Supply and fix Switch piano flush button single pole one way 15 amps 230 Volts with polycarbonate body all as specified and directed. Make : SSK Top Line/Legrand/Havells
Supply and fix socket 5 amps 5 pin flush type, 240 volts. with polycarbonate body complete all as specified and directed. Make : SSK Top Line/Legrand/Havells
Supply and fix socket out let, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts with polycarbonate body all as specified and directed. Make : SSK Top Line/Legrand/Havells
S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd, complete all as specified and directed
S & F electronic dimmers, 450W, 250V flush type on the exiting phenolic laminated sheet etc. as reqd, complete all as specified and directed
S&F ceiling rose , 3 phase/PVC/polycarbonate, isolated body surface Bakelite 65mm dia three terminals all as specified and directed. Make : SSK Top Line/Legrand/Havells
Dismantling and taking down fluorescent tube light single/double of any wattage or size street light fittings for repair or replacement of burnt/worn out accessories complete all as specified and directed.
S&F in repair energy saving 13.5 Watt LED IP 65 bulk head luminaries, complete with all accessories, internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size 230V,50 HZ all as specified and directed. Make : Cat Pt No LHEXCGP7IN5W013 of Havells or equivalent in Bajaj/Philips/CG
S & F LED batten with 2x20 watt tube light surface /wall mounted with specially designed powder coated aluminium housing , high optically efficient polycarbonate diffuser , in built electronic driver duly wired upto terminal block , power consumption is less than 2x20 W, luminarie lumen is greater than 2000 lms, system efficiecy is greater than 120lm /w , CRI is greater than 80 , LED Make : Nichia/Cree/Everlite/EClison/Osram/Lumiled with LED binning as per ANSI Bin C78.3777A, photo biological safety report as per IEC624718 & electrical insulation class 1, colour temp-5700K, Ingress protection IP 20, driver efficiency is greater than 85%, 50000 burning hours (min) as per L70 criteria, ambient, temp 0 to 500C, power factor is greater than 0.95 , THD is than 10%, surge protection is CM -2.5KV, two stages isolated constant current operated driver with range 150-270V AC and safety extra low voltage safe level is less than 60V DC as per IEC standard, with LM79& LM80 certification. all as specified and directed. Make : Cat Pt No LGP162LT8 for box type fitting and Cat Pt No LT8-20-865(2) for Tube Rod of Crompton or equivalent in Bajaj/Philips/Havells
S&F 2ft x 2ft recess mounted full panel LED luminaire with white powder coated aluminium hounsing acting as heat sink and frame in CRCA sheet high efficiency LED grade diffuser , in built electronic driver duly wired upto terminal block , power consumption less than 36 Watt , luminarie lumen is greater than 3500lm and system efficiency is greater than 120lm /w , CRI is greater than 80 , LED Make : Nichia/Cree/Everlite/EClison/Osram/Lumiled with LED binning as per ANSI Bin C78.3777A, photo biological safety report as per IEC624718 & electrical insulation class 1, colour temp-5700K, Ingress protection IP 20, driver efficiency is greater than 85%, 50000 burning hours (min) as per L70 criteria, ambient, temp 0 to 500C, power factor is greater than 0.95 , THD is than 10%, surge protection is CM -3KV, two stages isolated constant current operated driver with range 150-270V AC and safety extra low voltage safe level is less than 60V DC as per IEC standard, with LM79& LM80 certification all as specified and as directed all as specified and directed. Make : Cat Pt No : BZRSQL 36W GZI NW of Bajaj or equivalent in Havells/Wipro/CG
Supply and fixing building security light fitting new generation energy saving & environmental friendly long life versatile pressure die cast aliminium IP-66 high power LED light 30 watt Bajaj Cat No ENXT P30L WH CR PC SD complete with fixing arrangement including taking down of old U/s fitting any type all as specified and directed.
S&F in replacement sub Main Wiring with two single core PVC insulated unsheathed multistranded flexible copper conductor cable of size 2x6 sqmm and one single core PVC insulated multistranded unsheathed flexible copper conductor 1x4 sqmm size (green colour) cable as earthing lead connecting to main earthing dolly drawn in existing conduit complete all as specified and directed by Engineer-in-charge including taking down of existing un serviceable sub main wiring complete.Make Polycab/Finolex/RR Kablel/Grandlay
S&F in replacement sub Main Wiring with two single core PVC insulated unsheathed multistranded flexible copper conductor cable of size 4x6 sqmm and one single core PVC insulated multistranded unsheathed flexible copper conductor 2x4 sqmm size (green colour) cable as earthing lead connecting to main earthing dolly drawn in existing conduit complete all as specified and directed by Engineer-in-charge including taking down of existing un serviceable sub main wiring complete.Make Polycab/Finolex/RR Kablel/Grandlay
S&F in replacement sub Main Wiring with two single core PVC insulated unsheathed multistranded flexible copper conductor cable of size 2x4 sqmm and one single core PVC insulated multistranded unsheathed flexible copper conductor 2.5 sqmm size (green colour) cable as earthing lead connecting to main earthing dolly drawn in existing conduit complete all as specified and directed by Engineer-in-charge including taking down of existing un serviceable sub main wiring complete.Make Polycab/Finolex/RR Kablel/Grandlay
S&F in replacement sub Main Wiring with four single core PVC insulated unsheathed multistranded flexible copper conductor cable of size 4x 2.5 sqmm and one single core PVC insulated multistranded unsheathed flexible copper conductor 1x2.5 sqmm size (green colour) cable as earthing lead connecting to main earthing dolly drawn in existing conduit complete all as specified and directed by Engineer-in-charge including taking down of existing un serviceable sub main wiring complete.Make Polycab/Finolex/RR Kablel/Grandlay
Supply & fix in replacement sheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 4 way with IP-43 protection double door complete with appropriate size bus bar and neutral link all as specified and directed. Make : Legrand/Schneider/L&T/Hager
Supply & fix in replacement sheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 8 way with IP-43 protection double door complete with appropriate size bus bar and neutral link all as specified and directed. Make : Legrand/Schneider/L&T/Hager
Supply & fix in replacement sheet metal enclosure MCB distribution board. triple pole & neutral 415 volts 4 way with IP-43 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification all as specified and directed. Make : Legrand/Schneider (Acti-9)/Hager .
S & F V TPN distribution board iron clad, double door with IP-30 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with 250 A copper bus bar for each phase and 2 neutral link with 2 earth bar and cable ties for cable management fully insulated bus bar and shrouded neutral bars confirming to cat pt No 5077 40 DPX of Legrand equivalent of make Hager/C&S/Schneider (Acti-9)/L&T (Exora) complete with one MCCB 3 pole 415 Volts 160 Amps rating with rupturing cap 16 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge (Outgoing MCB will be measured separately).
Supply and fix MCB single pole 240 volts any rating from 6 to 32 amps, with rupturing capacity 10 KA `C' series including providing thimble for out going cables. Make : Legrand/Schneider (Acti-9)/L&T/Hager .
Supply and fix in replacement MCB double pole 240 volts any rating from 32 amps, with rupturing capacity 10 KA ` C' series, including providing thimble for out going cables. Make : Legrand/Schneider (Acti-9)/L&T/Hager .
Supply and fix in replacement MCB TP 415 volts any rating 63 amps, with rupturing capacity 10 KA ` C' series, including providing thimble for out going cables. Make : Legrand/Schneider (Acti-9)/L&T/Hager .
Supply and fix in replacement MCB isolator four pole415 volts any rating 100 amps, with rupturing capacity 10 KA ` C' series, including providing thimble for out going cables. Make : Cat Pt No 4086 80 of Legrand/Schneider (Acti-9)/L&T/Hager .
S&F in repair sheet metal enclosure with socket plug top and MCB single pole and neutral with two pin and earth plug top with one SP MCB 20 Amp 240 volt complete all as directed all as specified and as directed.
S&F in repair sheet metal enclosure with socket plug top and MCB three pole with three pin plug top with oneTP MCB 63 Amp415 volt complete all as directed all as specified and as directed.
Taking downceiling/wall fan, ceiling cable end, dismantling blades complete all as specified and directed.
Refixing ceiling/wall fan of any capacity received from item No - 75.00 here in before and connecting up including provision of cable from ceiling rose or connector to fan.
M&L for earthing complete with galvanised steel earth plate electrode size 600x600x6.0mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised earth lead wire 4.0 mm dia means of bolts, nuts, check nuts and washers of galvanised steel and GI pipe light grade 20mm dia bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including testing on completion. NOTES : 1. The unit rate includes for protection pipe and GI wire dia from top of earth plate up to 5.00 meter above ground level. 2. Filling of earth pit shall be done from vegetable soil,soil should be from any type of stone,aggregate,boulders or impurities except vegetable soil. 3. Rates of excavation, removal & returning filling of soil shall be deemed to be included .
M & L for Earthing for poles and other machinery/eqpt using GI strip as earth lead and MS galvanized steel earth plate electrode 600x600x 6.3mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate is not less than 1.5 mtr below normal ground level connected to galvanized iron strips 25x4mm with GI pipe, nuts, bolts and washers complete upto and including test point made out of 40x3mm GI flat, PCC pit of required size in PCC 1:2:4 type B1 and RCC cover with frame, charcoal, common salt15cm at round the earth plate watering pipe 20mm med grade/galvanized and 40mm dia GI pipe light grade for GI strip protected steel with funnel complete all as specified and directed as shown in electrical plate No 3 of SSR Part-I 2009. NOTES : 1. The unit rate includes for protection pipe and GI Strip dia from top of earth plate up to 5.00 meter above ground level. 2. Filling of earth pit shall be done from vegetable soil,soil should be from any type of stone,aggregate,boulders or impurities except vegetable soil. 3. Rates of excavation, removal & returning filling of soil shall be deemed to be included .
S&F earthing of machinary/ equipments installed at power house, substation/poles/building complete with copper earth plate electrode of size 60cm x 60cm x 3.15mm thick buried directly in ground (earth pit not less than 2.25 m deep below the normal ground level) with top edge of plate not less than 1.5m below normal GL, connected to copper earth strip 20 x 3.15mm as earth lead connected by means of bolts, nuts, washers check nuts made out of galvanized iron or steel all as shown on electrical plate No. 3 of SSR Part-1 connected to continuous copper earth strip complete all as specified and directed.
Supply & fixing Copper Earth strip of size 32x6mm Lead Fixed to wall on suitable procelain insulators of size 25 x 3 mm, complete all as specified and directed
Allied Builders
SHRI RADHAYSHYAM JHA
M/s J S & SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .