Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.5 LAccepted-AOC | L1 | Accepted-AOC Lowest quoted rate | |
| 2 | L2₹30.9 L+₹7.0 L (29.1%)Rejected-AOC | L2 | Rejected-AOC Other than lowest quoted rate | |
| 3 | L3₹30.9 L+₹7.0 L (29.2%)Rejected-AOC | L3 | Rejected-AOC Other than lowest quoted rate |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
27 Feb 2021, 6:00 pmClosed
Shri Ravinder Kumar AGE CONTRACTS
GE (S) Ahmednagar, Military Engineer Services, Ahmednagar- 414002
Repairs to all types of roof, roof treatment, ceiling and other misc B/R works at AGE B/R Aurangabad under GE (south) Ahmednagar
2021_MES_416999_1
8767/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
AURANGABAD
Class D cat a (i)
7 documents required · 7 mandatory
₹500
Garrison Engineer (S) Ahmednagar
₹60,000
Yes
3 Mar 2021
29 Jan 2021
1 Mar 2021
29 Jan 2021
27 Feb 2021
15 Feb 2021
29 Jan 2021 - 8 Feb 2021
Amount
Demolition of brickwork or stone/boulder masonry, built in cement mortar / cement lime mortar including all quoins, arches, pillars, etc complete all as specified and directed.
Brick work with sub class B bricks straight or curved on plan n exc 6m redius in CM 1:6 complete all as specified and directed.
Brick work with sub class B bricks straight or curved but except bricks in CM (1:6) complete all as specified and directed.
Taking down cement plaster of any description on brick or stone walls etc., including raking out joints, hacking for key, scrubbing down with water etc., complete all as specified and as directed.
15 mm thick rendering in CM 1:4 on stone masonary surfaces or other than fair faces of brick surface/ concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
12 mm thick rendering in CM 1:6 on fair faces of brick surface/ concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
10 mm thick rendering in CM 1:4 on ceiling surfaces, finished even and smooth without using extra cement complete all as specified and directed.
Preparation of new plastered or unplastered surfaces including cornices, pillars etc, and applying two coats colour wash over a coat of white wash complete all as specified and directed.
Preparation of new surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of walls including cornices, pillars etc, and applying three coats of white wash complete all as specified and directed.
Preparation of new plastered or unplastered ceiling surfaces and applying three coats of white wash complete all as specified and directed.
Preparation of newly plastered or unplastered old wall surfaces by washing, rubbing down and applying two coats of oil bound distemper over chalk whitening complete all as specified and directed.
Plain cement concrete 1:3:6, type C1 using 20 mm graded stone aggtregate as in roof kerbs or mud stops, rounded or chamfered on edge, including anchorage/ bed blocks or hold fasts etc complete all as specified and directed.
Taking up or down GI steel tubing and connections including cleaning for re-fixing or removal of 15 mm bore pipe complete all as specified and directed.
Taking up or down GI steel tubing and connections including cleaning for re-fixing or removal of 20 mm bore pipe complete all as specified and directed.
15 mm bore galvanised iron tubing medium grade, ISI marked, complete with all fittings and fixed complete, concealed in walls or laid in floors as in repairs complete all as specified and directed.
20 mm bore galvanised iron tubing medium grade, ISI marked, complete with all fittings and fixed complete, concealed in walls or laid in floors as in repairs complete all as specified and directed.
Refixing old GI steel tubing 15 mm bore and connections in new or old position (Walls, ceiling,floors, etc) complete with all new fittings and concealed in walls or laid in floors etc complete all as specified and directed.
Refixing old GI steel tubing 20 mm bore and connections in new or old position (Walls, ceiling,floors, etc) complete with all new fittings and concealed in walls or laid in floors etc complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut to facilitate demolition) complete all all as directed.
Precast cement concrete 1:2:4 using 20 mm graded aggregate in landings, cover slabs (for man holes etc.) chullah hoods, chajjas,water troughs,mangers, shelves and similar articles with plain faces complete all as specified and directed.
Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including crankng, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Mild steel TMT bars 6 to 8 mm dia , cut to length, bent to shape required, including crankng, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Gl frame work for seamless ceiling comprising of Gl perimeter channel 0.55 mm thick with two unequal flangesof 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre.incl necessary fixing/ repair /replacement of existing electrical fittings include dismantling at site complete all as specified and directed.
Hangers made out of 6 mm dia GI wire (up to 1200 mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of GI flat 40 x 3 mm size 60 mm long and expension hold fasteners 12.5 mm dia. 40 mm long complete all as specified and directed.
Exposed metal ceiling with 8 mm PVC board Ist quality fixing in 600 mm x 600 mm (frame work for celing shall be measured and paid separately) complete all as specified and directed.
Taking down rain water pipes (any size and pattern) including all fittings complete all as specified and directed.
110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls as in repairs complete all as specified and directed.
PVC (SWR) bends any radius with access door of 110 mm bore,fixed in repairs complete all as specified and directed.
Asbestos cement plain building boards 4 mm thick, fixed to mild steel frame work with screws in ceiling complete all as specified and diercted.
Preparation of surfaces of AC board celing and applying three coats of white complete all as specified and directed.
Dismantling of AC sheet (corrugated, semicorrugated etc) in roof covering including ridges complete all as specified and directed.
Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified, colour and design as approved by GE complete all as specified and directed.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridges, hips, valley gutters, drip and straight flashings fixed with self tapping screws as specified colour and design as approved by GE complete all as specified and directed.
6 mm thick asbestos cement corrugated or semi corrugated sheets in roof fixed with L type or J type or cranked hook bolts complete all as specified and directed.
All as per item No. 35 here-in-before but fixing only.
6 mm thick asbestos cement two piece serrated ridge for corrugated or semo-corrugated sheets as in roofs fixed with L type or J type or cranked hook bolts complete all as specified and directed.
Excavation in post holes (or similar poles) each n. exc 0.50 Cum, in soft / loose soil including returning, filling in and ramming earth in layers n. exc 25 cm, watering and removing surplus soil to a distance not exc 50 m and making good surfaces complete all as specified and directed.
Plain cement concrete 1:3:6, type C2, using 40 mm graded stone aggtregate as in roof kerbs or mud stops, rounded or chamfered on edge, including anchorage/ bed blocks or hold fasts etc complete all as specified and directed.
Rolled mild steel as in roof trusses (framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing ( beam, tee, angle, channel or flat sections) including distance pieces, cleat etc. Fe-410-W (Grade-E-250) quality B complete all as specified and directed.
Mild steel tubular pipes as in posts, purlins, rafters etc. including special shaped washers etc. complete using ERW or butt weld including welding, cutting etc complete all as specified and directed.
Rolled Mild steel Plates (plain or Chequred) channels, square cut or notched, forming holes, with riveted, bolted or welded attachment confirming to Fe 410-W (Gde E-250) complete all specified and directed.
Mild steel flat iron for wind ties for roof including securing bolts, drilling holes conforming to Fe-290 E-165 complete all as specified and diercted.
Mild steel screw bolts(machine made) with hexagonal or square heads at one end and screwed other, screwed to be fitted with washers and one hexagonal or square nut exc. 5 cm but not exc. 10 cm long, 11 to 15 mm dia complete all as specified & directed.
Preparation of new steel surfaces of any description over 10 cm width or girth & applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
Dismantling timber scantling in framed work in any position 40 sqcm and over in section complete all as specified and directed.
Dismantling timber as in fillets, rails, posts, rafters not exceeding 40 sqcm r in section complete all as specified and directed.
Dismantling batten for tiles of any size including tilting fillets n exc 15 cm spacing complete all as specified and directed.
Second class hard wood clean sawn timber as in scantling fixed complete all as specified and directed.
All as per serial item No. 49 here-in-before but except timber.
Second class hard wood plain fillets square, rectangular in section clean sawn, secured with nails, of sectional area exc 13 sqcm but not exc. 25 sqcm fixed complete all as specified and directed.
All as per serial item No. 51 here-in-before but except timber (fillets).
Second class hard wood plain fillets square, rectangular in section clean sawn, secured with nails, of sectional area exc 6 sqcm but not exc. 13 sqcm fixed complete all as specified and directed.
Clean sawn battens at spacing 15 cm centre to centre of IInd class hardwood of size exc 5 & nexc 15 sqcm sectional area complete all as specified and directed.
All as per serial item no. 54 here-in-before but except battens complete all as specified and directed.
Second class hard wood boarding 20 mm thick , clean sawn with butt joints fixed with nails in any situation complete all as specified and directed.
Dismantling of mangalore pattern or similar tiles in roofing complete all as specified and directed.
Roof tiles mangalore pattern, interlocking at side joints laid dry etc complete all as specified and directed.
Fixing only existing good condition roof tiles mangalore pattern, interlocking at side joints laid dry complete all as specified and directed.
Ridge or hip tiles to suit mangalore pattern of roofing tiles, bedded and jointed in cement morter 1:6 complete all as specified and directed.
Fixing only ridge or hip tiles to suit mangalore pattern of roofing tiles, bedded and jointed in cement morter 1:6 complete all as specified and directed.
Preparation of new wooden or wood based surfaces of battens of any size and spacing (as in roof for manglore tiles ) and treated with creosote oil complete all as specified and directed.(Measured overall on one side only)
Preparation of new wooden or wood based surfaces of any description and treated with creosote complete all as specified and directed.
Disconnecting existing PVC tanks, exc 250 and not exc 500 Ltrs capacity, setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and re-fixng in position including cleaning and removing all scales and dirt etc from mouths of circulating pipe etc. complete all as specified and directed.
Disconnecting existing PVC tanks, exc 500 and not exc 1000 Ltrs capacity, setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and re-fixng in position including cleaning and removing all scales and dirt etc from mouths of circulating pipe etc. complete all as specified and directed.
Taking down carefully existing bituminous felt including plastered lime or cement concrete of any thickness and cleaning of the surface of roof treanches including flushing and junction parapets kerb walls PCC fillets beanching etc with wirre brushes and removing of the rubbish to a distance not exc 500 mtrs and depositing where directed at a level not exc 1.5 mtrs above the starting point complete all as specified and directed.
Cutting out cracks to V section in existing roof or terrace, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand (1:1) by weight complete all as specified and directed..
Demolition of unreinforced cement concrete on roofs, floors and paving other than ground floors n.exc 15 cm thickness complete all as directed.
25 mm thick cement concrete type B-0, 1:2:4 (12.5 mm graded aggregate) by using WPC @ 3% by weight of cement surface finished even and smooth complete all as specified and directed. (WPC will be paid seperately).
Supply only water proofing compound complete all as specified and directed.
APP polythene membrane minimum weight 3kg/sqm and minimum 3 mm thick reinforced with polyster non wooven fabric including aluminium foil on top weighing not less than 150 gms/sqm laid on primed surfaces by forced application including bituminious primer @ 0.30 Litr/Sqm complete all as specified and directed.
Applying of two coats of aluminium paint over APP membrane laid over roof complete all as specified and directed.
Cement concrete 1:2:4, type B0 using 12.5 mm graded stone aggegate as on undulated surfaces or in copings, kneelers, roof kerbs and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work where required complete all as specified and directed.
Precast cement concrete, 1:2:4 type B1 using 20 mm graded stone aggragate in window or door cills, lintels ,bressumers steps quoin blocks (for use with masonry) string courses, copings kneelers, apex stones, pier caps, columns , posts , plasters , pintle blocks, bonders, (for stone wallings) , crobels brackets, etc. ( of any section indicated) with plain fair faces including chamfers, weatherings, throating etc. and setting in mortat complete with joints to match all as directed.
Providing precast cement concrete louvers and jallies 25 mm thick in cement concrete1:2:4, type B0,using 12.5 mm graded aggregate (measured solid) including all moulding but excluding frame complete all as specified and directed.
M/s.M G Kulkarni
M/S. M.A. Sharief engineers and contractors
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .