| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.3 LAccepted-AOC CB 1 MAHAVEER NAGAR BARMER 344001 RAJ | BARMER | RAJASTHAN | 344001 | L1 | Accepted-AOC AOC | |
| 2 | L2₹11.9 L+₹2.0 L (20.7%)Rejected-Finance 205 IIND PHASE INDUSTRIAL AREA BARMER 344001 | BARMER | BARMER | RAJASTHAN | 344001 | L2 | Rejected-Finance Other than lowest |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
16 May 2023, 6:00 pmClosed
GE (AF) Utarlai
GE (AF) Utarlai PB No. 11 Barmer (Raj) 344001
REPAIR TO ELECTRICAL SUPPLY LT NETWORK, WATER SUPPLY, INTERNAL ELECTRIFICATION AND SUMMER APPLIANCES AT CHAUHTAN HILL UNDER GE (AF) UTARLAI
2023_MES_590000_1
8402/E8
Open Tender
Civil Works
Item Rate
180 days
Utarlai
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) Utarlai
₹24,000
Yes
31 Jul 2023
18 Apr 2023
18 May 2023
19 Apr 2023
16 May 2023
2 May 2023
Amount
Supplying, fixing and testing in replacement of Street lights LED type 45W pressure die cast aluminium housing luminaires complete including taking down old street light any type complete all as specified and directed by Engr-in-Charge.
Supplying, fixing and testing in replacement of Street lights LED type 60W pressure die cast aluminium housing luminaires complete including taking down old street light any type complete all as specified and directed by Engr-in-Charge.
Supplying, fixing and testing in replacement of Flood lights LED type 120W pressure die cast aluminium housing luminaires complete including taking down old street light any type complete all as specified and directed by Engr-in-Charge.
M&L for preparation of old painted surface, cleaninig of oils, lubricants, grease etc complete of any type of 11.0 mtr long poles as per IS above PCC coping with applying 2 coats of aluminium paint including brackets, cross arms clamps including writing pole Nos as before complete all as specified and directed by Engr-in-Charge.
M&L for preparation of old painted surface, cleaning of oils, lubricants, grease etc complete of PCC LT 9.0 mtr long poles as per IS above PCC coping making five strips of 300 mm size alternative with black and white paint with 2 coats of synthetic enamel paint including writing pole Nos as before complete all as specified and directed by Engr-in-Charge.
M&L for preparation of old painted surface, cleaning of oils, lubricants, grease etc complete of Steel tubular 9.0 mtr long poles as per IS above PCC coping with applying 2 coats of aluminium paint complete including making 5 strips of size 300mm alternative with black and white paint including writing pole Nos as before complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of automatic street light switch using Nature Switch for automatic switching of street lights based on LUX level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (Input-output) should be enclosed in pole/wall mountable enclosure made of rust proof, Electric shock proof, termite proof and FR grade SMC junction box (sintex make) conforming to IP 54.the contactor,MCBs and copper circuit wiring (min.10 sqmm) should enough to take: three-phase load of 8 KW;contactor Rating 25 Amps per phase; MCB Rating 32 Amps per phase complete all as specified and directed by Engr-in-Charge. MAKE:-Nature switch :Kakatiya energy systems pvt.ltd. hyderabad/bajaj/healer. Model no SWADEEP-02EC-5KW3P SPD.
Decarburizing /cleaning complete LT 415 Volts 3 phase panel/ bus bar chamber with electrical connections, complete bus bar from the bus bar chamber, cleaning and ensure proper decarburizing, refixing the same after applying Backtol Red solution to the bus bar insulator & checking all the connections, tightening the nuts, bolts & thimbles of in-coming/out-going system complete incl replacement of defective rusted bolts & nuts all as specified and directed.
M&L for painting on out door/ indoor LT panels/Bus bar chamber, with removing rust by wire bushes, applying painting of panel surface of any description using synthetic enamel paint of two coats by using spray gun after preparation of old painted surfaces complete all as directed
Supply and fixing in replacement of MCCB 4 pole, 415 V, adjustable type 100 Amps with breaking capacity 16 KA including necessary modification in the panel complete including taking down old u/s MCCB any type all as specified and as directed.
Supply and fixing in replacement of MCCB 4 pole, 415 V, adjustable type 63 Amps with breaking capacity 16 KA including necessary modification in the panel complete including taking down old u/s MCCB any type all as specified and as directed.
M&L for 'B' Check once in Six month OR 250 Hrs running whichever is earlier DG sets of capacities as mentioned under respective item of BOQ, inspection, maintenance and serviceing including alternator, electric panel board connection to DG set etc for smooth functioning and carrying out maintenance as per OEM instructions and as directed by Engr-in-Charge. Note: (i) 'B' Check Service shall be carried out as described in respective item of BOQ (ii) Items/ Spares including 'B' Check kit, coolent, lubricating oil required shall be measured and paid separately under respective item of BoQ (i) Repeat the activities of 'Á' Check services (ii) Replacment of lubricant oil. (iii) Replacing lubricant oil filters element with O rings (iv) Replacing fuel filters element with O rings (v) Replacing air filter elements with O rings (vi) Replacing coolant.
320 KVA Capacity, Location : Chauhtan Hill Top
100 KVA Capacity, Location : Chautan Base
15 KVA Capacity, Location : Chauhtan Base
Supply only 'B' check kit for DG set of following capacities as mentioned in respective item of BOQ. Note : It includes oil filters (1.00 Ltr/0.5 ltr), Diesel filters and air filters inner and outer as recommended by OEM
320 KVA Capacity, Location : Chauhtan Hill Top
100 KVA Capacity, Location : Chautan Base
15 KVA Capacity, Location : Chauhtan Base
Supply only coolent , K cool super plus 50-50 Premix
Supply only battery water with electrolyte mix as recommended and approved by Engr-in-Charge.
Supply only Engine oil 15 W 40 turbo synthetic superior quality engine oil
Supply only in replacement of fan belt set suitable for 100 KVA
M&L for complete checking of AMF panel, finding the fault, servicing complete including replacement of unserviceable spares with necessary wiring and testing complete for manual & automatic operations complete all as specified and directed. Note : -Items required for replacement will be measured and paid separately under respective item of BOQ
Supply only in replacement of under and over voltage timing relay of AMF panel as per existing type, make and capacity complete including taking down old u/s under and over voltage relay any type all as specified and directed.
Supply only in replacement of AMF panel timer relay for circuit 230 v AC supply as per existing type, make and capacity complete including taking down old u/s timer relay any type all as specified and directed.
Supply, install, testing and comissioning in replacement of tubular batteries 12 V, 180 AH including copper terminal lugs complete and disconnecting old unserviceable 12V, 90ah battery with copper terminal lugs complete.
Supply & Laying in replacement in trenches or fixing on wall or passing through pipe or in cable ducts, 1100 volts grade XLPE armoured, electric power cables (heavy duty) with aluminium conductor of the following size . Note: The rate quoted will be inclusive of termination at ends with suitable aluminium lugs wherever required and taking down old u/s cable any size and type.
50 sqmm 3.5 core
25 sqmm 4 core
16 sqmm 4 core
Excavation in trenches not exceding 1.5m wide and not exceding 10.0 sq m on plan and not exceding 1.5m depth and getting out soft/loose soil complete all as specified and directed.
Returing filling in including spreding leveling watering and well ramming in layer not exceding 25 cm as in soil complete all as specified and directed.
Removing excavated material not exceding 50 m and depostingwhere directed at a level not exceding 1.5 m above the starting point complete all as specified and directed.
M & L for sand cushioning all around the cable for protection by natural tibba sand complete all as specified and directed.
Supplying and Laying stone patti 40-50 mm thick, 25- 30 cm wide abutting each other for cable protection complete all as specified and directed.
M&L in replacement of Earthing complete with 600x600x6.3MM thick GI earth plate electrode burried directly in ground not less than 2.25 mtr below GL with the top edge of the plate at a depth not less than 1.5 mtr from GL, connected to GI earthstrip size 32x6mm dia by means of nuts, bolts, washers, checknuts etc, made out of galvanised iron or steel, earth wire protected by galvanised iron pipe, connected to main switch board complete including necessary earth work, excavation, PCC chamber, watering pipe, funnel, wiremesh, RCC chamber cover etc all as specified and directed. Note:-(i) GI strip 32x6 mm upto 7.5 mtr length shall be deemed to include in this items rate.(ii) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost by the contractor.
Supply and lay in replacement of steel water tubing GI medium grade ISI marked with all fittings laid in trenches etc complete for the following sizes including taking out old uerviceable pipe lines all as directed by Engr -in- Charge :-
25 mm bore
40 mm bore
50 mm bore
80 mm bore
Supply and fix Gun - metal, globe or gate valve ISI marked with iron wheel head, screwed at both ends for iron pipes and fixed with suitable size of union for the following sizes including taking out old unserviceable gate valves complete all as specified and directed by Engr -in- Charge :-
25 mm dia bore
50 mm dia bore
Repair and servising (Twice in year) of RO water plant 150 ltr per hr installed in ORs Mess and hill top Ops Room with the following works :- (a) Replace the UV filter with assembly . (b) Dismantling of RO unit and cleaning RO water storage tank,membrain ,removing inlet/outlet pipe line and replace the Chemical tube complete servising and cleaning the unit all as airby Engr-in- charge (c) Replacement of RO membrain. (d) Replacement of unsv motors of RO plant Note :- Cost of unserviceable spare parts deemed to be included in quoted rates
M& L for testing of water for potability and biological analysis etc from the specified lab complete all as specified and directed.
M&L repairing of Submersible pump set with multi stage, electric driven 415 volt,50Hz capacity 5 HP including taking up from borewell with column pipe and lowering down by using of tripod/lowring machine with chain pulley 5 ton capacity complete all as specified and directed. (a) cost of Transportation of burnt motor to civil electric work shop deemed to be including in the quoted rate. (b) Dismantling of motor, cutting and taking out burnt stator winding from motor cleaning the stator and rewinding with super enameled copper wire of original gauge / size with suitable for submersible motor, including tapping, Motor end shield, shaft sheild assembling and carrying to site including necessary connection, commissioning and testing on full load (Major spare parts will be measured and paid separately under respective items) (c) The nuts bolts/rubber gasket of column pipe will be replaced by new one. and cost for the same to be included in the quoted rate. Note :- Cost of minor spare parts deemed to have been included the quoted rates by the tenderer
S&F in replacement of following under mentioned worn out U/S parts of submersible pump set 5 HP for bore well complete all as specified and directed.
Bearing
Strainer
Shaft seal
M&L repairing of Submersible pump set multi stage, electric driven 415 volt,50Hz capacity 20 HP including taking up from Under Ground sump and refixing the same after repair by using tripad/ lowring machin ewith chain pulley complete all as specified and directed by Engr-in-Charge. (a) cost of Transportation of burnt motor to civil electric work shop deemed to be including in the quoted rate. (b) Dismantling of motor, cutting and taking out burnt stator winding from motor cleaning the stator and rewinding with super enameled copper wire of original gaug suitable for submersible moto,r end shield, shaft sheild assembling and carrying to site including necessary connection, commissioning and testing on full load (Major spare parts will be measured and paid separately under respective items) Note :- The above quoted rates inclusive the cost of minor spare parts.
Supply and fixing in replacement of following under mentioned worn out U/S parts of submersible pump set 20 HP for UG sump all as directed.
Bush bearing
Strainer
Shaft seal
Taking down unserviceable point wiring any type for light/fan/socket/power with all fittings and fixtures,tube lights complete all as specified and as directed
Material and labour for point wiring complete with 1.5 sqmm single core multistandard copper conductor fire resistant low smoke and low halogen (FRLSH) PVC insulated and unsheathed cable 1100 Volts grade conforming to IS-694 drawn through non metallic rigid PVC heavy duty conduit in concealed (min 20mm dia (external) but shall be increased as per actual site requirement in accordance with clause No 19.125 of SSR Part I) ISI marked with wall thickness not less than 1.8mm including conduit accessories like bends, tees, junction boxes etx fixed concealed/recessed in wall or ceiling etc including 1.5mm FRLSH PVC insulated unsheathed copper earth wire including sunken type pressed steel terminal boxes electro plated of suitable size with bakelite white/colored top sheet cover 3.0mm thick for :-
One light point controlled by one way switch.
One Ceiling Fan/Wall Mounted Fan/Exhaust Fan Point controlled by one way switch
One 3 pin 6 Amps socket outlet on same board
One 3 pin 6 Amps switch socket out on indipendent board
Taking down carefully U/S by unscrewing from boards/outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings, tube rods and regulators, etc. complete all as specified and directed.
S&F switch 5 Amp piano flush type single pole one way complete all as specified and directed.
S&F switch socket combination flush type 5 Amps, 2/3 pin multipurpose complete all as specified and directed.
S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings
S&F for replacement of LED lamp 9 Watt more than 120 lumen per watt efficiency complete all as specified and directed.
S&F switch/socket combination outlet 2 in 1, 3 pin 5 Amps and 15 Amp flush type (Multi purpose) piano type AC 230 Volts.
S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet, etc as required complete all as specified and directed.
S&F ceiling rose three terminal AC 230 volts complete all as specified.
S&F in repair LED tube light fitting 1 x 20w, 230v including LED (tube rod), 4 feet batten fitting fixtures, complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size, complete all as specified and directed.
S&F in repair LED tube light fitting 1 x 10w, 230v including LED (tube rod), 2 feet decorative ultra slim LED fixture with high lumen output, environment friendly energy efficient complete with all accessoires pre wired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
S&F in repair LED tube rod 20w, 230v 4 feet complete all as specified and directed.
Taking down ceiling fan of any make & sweep by disconnecting clips, lock nuts etc. from existing position of any height in safe custody for repair & maintenance, complete all as specified and directed. (Note :- Repair & maintenance shall be paid saperately under relevant items)
Hanging only ceiling fan 1200mm/1400mm sweep after repair & maintenance with existing down rod, shackle, canopy, clips, lock nuts etc complete all as speficied and directed.
M&L for painting of ceiling fan complete, in situ/lying in store with synthetic enamel paint (white colour) by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed.
M&L for removing of old burnt winding wire of fan any type and rewinding the stator with superior quality super enamelled copper wire of suitable size including insulation, drying after varnishing complete all as specified and directed.
S&F in replacement of bearing for ceiling fan 1200mm/1400mm sweep ISI marked complete all as specified and directed.
S&F in replacement of gun metal bush for ceiling fan 1200mm/1400mm sweep complete all as specified and directed.
S&F in replacement of rubber shackle and split pin with galvanised clamp complete with nuts, bolts and washers complete all as specified and directed
Taking down exhaust fan of any make & sweep and size from existing position of any height for repair, maintenance and refixing the same after necessary repair complete all as directed. Note : (i) The defective parts to be replaced and shall be measured and paid separately under relevant item of Sch. (ii) cost of minor items i.e., Screws, nut & bolts etc shall be deemed to be included in the above item.
S&F in repair ball bearing (ISI mariked) for exaust fan of 450mm sweep capacities
S&F in repair ball bearing (ISI mariked) for exaust fan of 300/380mm sweep capacities
M&L for removing of old burnt winding of exhaust fan 450mm sweep motor and rewinding the same with superior quality super enamelled copper wire of suitable size including insulation, drying after varnishing complete all as directed and specified by Engr-in-Charge. Note : Cost of dismantling all components of exhaust fan, greasing, re-assembling and complete testing shall be included in the quoted rate.
M&L for removing of old burnt winding of exhaust fan 300/380mm sweep motor and rewinding the same with superior quality super enamelled copper wire of suitable size including insulation, drying after varnishing complete all as directed and specified by Engr-in-Charge. Note : Cost of dismantling all components of exhaust fan, greasing, re-assembling and complete testing shall be included in the quoted rate.
M&L for removing of old burnt winding of falme proof exhaust fan 450mm sweep motor and rewinding the same with superior quality super enamelled copper wire of suitable size including insulation, drying after varnishing complete all as directed and specified by Engr-in-Charge. Note : Cost of dismantling all components of exhaust fan, greasing, re-assembling and complete testing shall be included in the quoted rate.
S&F in repairs of capacitors 3.15mfd ISI marked complete all as directed.
S&F in repairs of capacitors 4 mfd ISI marked complete all as directed.
Supply and fixing in replacement MCB SP, 6 to 32 Amps 10 KA single pole AC 230 volts 'B' curve complete all as specified
Supply and fixing in replacement MCB SPN 6 to 40 Amps 10 KA AC 230 volts 'B' curve complete all as specified
S&F in replacement of Sheet metal enclosures for fixing MCBs Single pole and neutral 8 way, 240 volts with 200 Amps rated bus bar with double door fixed on flush to the wall including making the hole in the wall and fixing the DB including making good the disturb surface complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Sheet metal enclosures for fixing MCBs Single pole and neutral 4 way, 240 volts with 200 Amps rated bus bar with double door fixed on flush to thee wall including making the hole in the wall and fixing the DB including making good the disturb surface complete all as specified and directed by Engr-in-Charge.
S&F in replacement of submain wiring with two runs of 4.0 sqmm single core FRLSH PVC insulated stranded copper conductor cable drawn through rigid non metallic PVC conduit with one run of 4.0 Sqmm PVC insulated copper conductor cable as earth continuity conductor and necessary connections complete all as specified and directed by Engr-in-Charge. Note : Three (2+1) runs of 4 sqmm FRLSH PVC insulated unsheathed copper conductor PVC insulated unsheathed copper conductor and 1 run of PVC conduit of size 20 mm will be measured as single run
M&L in replacement of Earthing complete with 600x600x6.3MM thick GI earth plate electrode burried directly in ground not less than 2.25 mtr below GL with the top edge of the plate at a depth not less than 1.5 mtr from GL, connected to GI earth lead wire of 4.0 mm dia by means of nuts, bolts, washers, checknuts etc, made out of galvanised iron or steel, earth wire protected by galvanised iron pipe 15mm dia, connected to main switch board complete including necessary earth work,excavation,PCC chamber, watering pipe, funnel, wiremesh, RCC chamber cover etc complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of FLP/WP switch 16 Amp, 250V single pole ON/OFF rotary type with termination box in LM6 complete all as specified and directed by Engr-in-Charge.
S & F in replacement of Flame proof weather proof LED 1x20 watt tube light fixture 4 feet including LED 20W tube rod 4 feet,including integral reflector made of alluminium alloy LM6 with wire guard,bipin holders,.connector block, etc., and all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor with suitable size recommended for gas/vapour group of IIA & IIB and zone 1&2 IP 66 protection surface mounted LED batten complete all as specified and directed by Engr-in-Charge.
M & L for servicing of split type AC of capacity 1.5 /2 TR of any by cleaning of filter on front side including fins, checking of refrigerant standing pressure, topping of refrigerant upto the required level, complete all as directed by Engineer-in-Charge. Note : Refrigerant required for topping (R-22 / R-134/R410(a) shall be maesured and paid for separately.
Supply only of Refrigerant gas R 22/ R-134/ R-410(a) in cylender complete all as specified and directed
S&F in replacement of Blade for condensing fan motor of split AC capacity 1.5/2.0 TR suitable make complete all as specified and directed by Engr-in-Charge.
S&F in replacement of blower of indoor unit of split AC capacity 1.5/2.0 TR suitable make complete all as specified and directed by Engr-in-Charge.
S&F in replacement of condensor fan moter of split type AC suitable for 1.5/2.0 Ton capacity of suitable make complete all as specified and directed by Engr-in-Charge.
S&F in replacement of blower fan moter of split type AC suitable for 1.5/2.0 Ton capacity of suitable make complete all as specified and directed by Engr-in-Charge.
S&F in replacement of rotery Compressor (Sealed Unit) of window / split type AC 2 TR capacity, single phase, 220 volt of suitable make including necessary modification of foudation as required to suit the compressor, vacumisation, pressure testing, leakage rectification including gas charging R-22/134 & testing complete all as specified and directed by Engr-in-Charge.
S&F in replacement of rotery sealed Compressor (Sealed Unit) of window / split type AC 1.5 TR capacity, single phase, 220 volt of suitable make including necessary modification of foudation as required to suit the compressor, vacumisation, pressure testing, leakage rectification including gas charging R-22/134 & testing complete all as specified and directed by Engr-in-Charge.
S & F in replacement of wiring kit of split type AC complete with lugs, thimble of suitable make complete all as specified and directed by Engr-in-Charge.
S & F in replacement of Running Capacitor 45/50 Mfd complete all as specified and directed by Engr-in-Charge.
S & F in replacement of Running Capacitor 6 Mfd complete all as specified and directed by Engr-in-Charge.
S & F in replacement of Running Capacitor 2.5 Mfd complete all as specified and directed by Engr-in-Charge.
S & F in replacement of Running Capacitor 4 Mfd complete all as specified and directed by Engr-in-Charge.
S & F in replacement of Running Capacitor 1.5 Mfd complete all as specified and directed by Engr-in-Charge.
S & F in replacement of Running Capacitor 2 Mfd complete all as specified and directed by Engr-in-Charge.
S & F in replacement of Running Capacitor 3 Mfd complete all as specified and directed by Engr-in-Charge.
S&F in replacement of harmatically sealed Compressor (Sealed Unit) of water cooler 40/80 ltr capacity, single phase, 220 volt of suitable make including necessary modification of foudation as required to suit the comptessor, vacumisation, pressure testing, leakage rectification including gas charging R-22/134 & testing complete all as specified and directed by Engr-in-Charge.
S&F in repairs trasformer windings suitable for 5 KVA voltage stabilizer complete all as specified and directed by Engr-in-Charge.
S&F in repairs PCB circuit with relay, internal wiring, on/off switch, 5/15 amp sockets, input cable lead 4 sqmm 3 core (1.5 m long), limit switch etc suitable for 5 KVA voltage Stabilizer complete all as specified and directed by Engr-in-Charge.
S&F in replacement of display unit suitable for 5 KVA voltage stabilizer as per existing make and model complete all as specified and directed by Engr-in-Charge.
S & F in replacement of PCB Senser unit of split AC indoor unit of Capacity 1.5/2 TR of suitable make & capacity & model in the same position complete all as specified and directed by Engr-in-Charge.
S&F in replacement of pencil cell suitable of cordless type remote complete all as specified and directed by Engr-in-Charge.
S & F in replacement of plug and socket outlet industrial type 250 Volts with MCB SP 20 AMP, C Curve complete all as specified and directed by Engr-in-Charge.
Material and labour for cleaning and painting to old steel surfaces of Desert cooler with two coats of synthetic enamel spray paint over one coat of red oxide on external surface & two coats of anti corrosive black paint inside the Body tank & side grills over a coat of Red Oxide primer including scraping/rubbing with wire brush on old surface of Desert cooler and Re-writing of MES No and date of painting done complete all as specified and directed.
S&F in replacement of Desert Cooler fan motor capacity 1/5 HP, 1400 RPM single phase with fan blade and stand complete all as specified and directed by Engr-in-Charge.
S&F in replacement of water lift submersible pump plastic body of 220-240 Volts AC Supply single phase complete all as directed by Ein- Charge .
S&F in replacement of wood wool pad (set of three), minimum weight 0.80 Kg, fixed in side panels of desert coolers including GI wire mesh of 20 gauge wire and mesh size 100x100mm complete all as specified and directed by Engr-in-Charge.
S&F in replacement of side penal (shutter) made out of 22 gauge PGI Sheet with suitable hand grip,and supporting jali of wood/wool chips pad set made out of hard MS wire and fitted in side louvers including painting to match with the existing desert cooler complete all as specified and directed by Engr-in-Charge.
S&F in replacement of 20mm size of Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed including nipple and fixing accessories complete all as specified and directed.
S&F in replacement of 5 A switch piano type suitable for submersible pump of capacity 40Watt for desert cooler all as specified and directed.
Supply and fix in replacement of copper condensing coil for split AC 1.5/2.0 Ton as per existing make and model complete all as specified and directed
S&F in replacement of harmatically sealed Compressor (Sealed Unit) of deep freezer 500 ltr capacity, single phase, 220 volt of suitable make including necessary modification of foudation as required to suit the comptessor, vacumisation, pressure testing, leakage rectification including gas charging R-22/134 & testing complete to the entire satisfaction of Engr-in-charge & depositing the old compressor in E/M store yard complete all as specified and directed by Engr-in-Charge.
National Rewinding Works
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .