Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Not Admitted-Fee/PreQual/Technical/Finance B 10 KRISHNA IND ESTATE BIDC GORWA VADODARA 390016 | VADODARA | VADODARA | GUJARAT | 390016 | Not Admitted-Fee/PreQual/Technical/Finance Not qualified for AOC |
Tender Value
Refer Docs
Closing Date
12 Feb 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Cheif Engineer Jodjpur Zone
HQ CHIEF ENGINEER JODHPUR ZONE
Consultancy for preparation of design,drawng and rate analysis for constr of 01xac msl shed 250 mt capacity for storage of unhd 1.1 amn (msl) and allied infrastructure at 75 (i) inf bde gp omc, bhuj mil station
2021_MES_416798_1
300300/20-21/27/E3
Open Tender
Miscellaneous Works
Supply
45 days
HQ CHIEF ENGINEER JODHPUR ZONE
As per NIT
1 document required · 1 mandatory
₹0
Exempted
15 Feb 2021
28 Jan 2021
15 Feb 2021
28 Jan 2021
12 Feb 2021
28 Jan 2021
90 days
CONSULTANCY FOR PREPARATION OF DESIGN,DRAWNG AND RATE ANALYSIS FOR CONSTR OF 01XAC MSL SHED 250 MT CAPACITY FOR STORAGE OF UNHD 1.1 AMN (MSL) AND ALLIED INFRASTRUCTURE AT 75 (I) INF BDE GP OMC, BHUJ MIL STATION (a) Design of energy efficient central air conditioning plant of suitable capacity based on inside/outside conditions. Inside conditions to be obtained from GE on given data sheet attached as Appendix. The design shall meet relevant code requirements and should as per latest IS practices. It should include the following:- (b) Data based heat load calculations for AHU as per site plan. (c) Double line duct drawing showing different sizes of ducts air flow details. (d) Chiller water piping drawing including condenser pipes and fitting with details of dia. (e) Layout Schematic line diagram of LT control panel suitable for the plant showing all the details such as main incoming, outgoing and their type, capacities, qty, alongwith connected measuring instrument/meters, indication lamp starters, MCB, MCCB isolator etc. (f) Specification/description of equipment and other materials/items with technical literature of various components. (g) Recommendation of type of plant with detailed justification depending upon heat load to meet the desired condition specified in data sheet to be obtained from GE in consultation with user as per format attached as Appendix. (h) Line plan of Plant AHU showing various eqpt/items with diamension of various eqpts/item with specific working clearance between eqpts to eqpts and from walls, after due consideration existing doors and windows (j) Schedule of item/description of equipment of all items with accounting unit, qty and particular specification etc. (k) Full description of items/eqpt of schedule with recommended brand /make, listing various items & their recommended brands/makes. (l) Inside design conditions are required to be maintained irrespective of minor variation in outside conditions.
Note :- (i) Consultant should submit 2 Nos CD showing detailed design with description/specification complete along with heat load calculation (For summer, winter & monsoon) design, drawing bill of quantities and two nos hard copies. (ii) Outside design conditions at GE (A) Bhuj area can be obtained from concerned metrological authorities. (iii) Consultant will develop the soft copy of all the drawings required for the work on the basis of hard copy /line plan of the project. (iv) The details given in appendix ‘A’ are tentative, Consultant has to obtain firm details as per Appendix ‘A’ & ‘B’ from GE (A) Bhuj in consultation with users. (v) Atmospheric/any other required datas to be obtained from concerned metrological deptt/Govt institutions. (vi) DPR should be vetted along with its drawing from IIT/NIT. (vii) Noise level (sound pressure) should not exceed the permissible limits. (viii) Consultant should provide rate analysis for all the connected equipment’s.
Sai Geotechnical Lab
stage.html
html • 0.02 MB
finance_465441.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .