Tender Value
₹56.1 L
EMD Value
₹1.1 L
Closing Date
15 Jun 2026, 4:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
ELECT.G
17 conditions · 5 needing a document upload
Financial Eligibility Criteria: (Ref: RB letter No. 2022/CE- I/CT/GCC2022/POLICY : Advance Correction Slip No.-1 dt 14.07.2022) The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-I, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The intending tenderers should possess a valid electrical contractor license at the time of opening of tender, issued by any state government & same should be submitted along with tender documents by all bidders including working contractors of this unit otherwise offer shall be summarily rejected....... IT SHOULD BE NOTED BY THE TENDERER THAT ELECTRICAL LICENSE UNDER RENEWAL AT THE TIME OF TENDER OPENING WILL NOT BE CONSIDERED AND OFFER WILL BE SUMMARILY REJECTED. IT IS THE RESPONSIBILITY OF TENDERER TO UPLOAD VALID ELECTRICAL CONTRACTOR LICENSE ON THE DATE OF TENDER OPENING.
All requisite documents mentioned in clause 3.7 of the tender document attached pertaining to constitution of firm/concern. (As applicable).
36 conditions · 4 needing a document upload
The rate to be quoted by tenderer shall be inclusive of all state/central taxes including GST. THE TENDERER SHOULD UPLOAD VALID GST REGISTRATION CERTIFICATE ALONG WITH THE OFFER.
The tender shall comply with General Condition of contract (GCC),2022 of Indian Railways (file attached). and its latest amendment, if any. The tenderer shall submit the offer after duly satisfying himself/herself with the GCC,2022 in general.
Tenderers are required to upload the Bank details as per Annexure-XII (Real Time Gross Saving (RTGS)/National Electronic Fund Transfer (NEFT) Model Mandate Form)of tender document.
Tenderers are required to upload requisite details as per Annexure-VIIB (DETAILS OF CONTRACTUAL PAYMENT RECEIVED IN LAST THREE FINANCIAL YEARS AND CURRENT FINANCIAL YEAR) without which the offer is liable to be rejected.
Tenderers are compulsorily required to upload Affidavit as per Annexure-XXIV along with tender document, without which the offer will be considered incomplete and will be rejected summarily.
All requisite documents/credentials mentioned in clause 3.5 of the tender document attached pertaining to his/their technical and financial eligibility. (As applicable).
All requisite documents mentioned in clause 3.7 of the tender document attached pertaining to constitution of firm/concern. (As applicable).
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
No post tender correspondence for submission of additional documents shall be entertained after opening of the Technical & Commercial offers. Even suo-moto post tender letters of the tenderer/s shall be treated as Null & Void.
This tender complies with Public Procurement Policy (Make in India) Order 2017, dated 15/06/2017, issued by Department of Industrial Promotion and Policy, Ministry of Commerce, circulated vide Railway Board letter no. 2015/RS(G)/779/5 dated 03/08/2017 and 27/12/2017.
IF ANY DISCREPANCY IS FOUND IN THE TENDER DOCUMENT, NAMELY SOR ITEM DESCRIPTION, SPECIAL TENDER CONDITION ETC., CLARIFICATION CAN BE SOUGHT FROM THE OFFICE OF SRDEE/G/DLI, DRM OFFICE, STATE ENTRY ROAD, NEW DELHI.
This tender complies with Railway Board instructions for Startups (recognized by Department of Industrial Policy and Promotion, Ministry of Commerce and Industry) for exemption from payment of Bid Security as detailed in GCC 2022 as amended from time to time. Such Startup firms may note that no other exemption is applicable to them in this particular tender.
On account payment, contractor shall submitted indemnity bond with validity up to the completion/extended period in the prescribed format (please refer Annexure-XXVIII) at the contractor's cost, vesting the ownership of such material with the railways.
This tender shall also complies with "Indian Railways Standard General Conditions of Contract, April 2022 (Advance Correction Slip No. 11)" vide Railway Board letter No. 2022/CE-I/CT/GCC- 2022/POLICY/Pt.I (E-3320424), dated: 13.03.2026 (attached)
The rate to be quoted by tenderer shall be inclusive of all state/central taxes including GST. tenderer shall submit GST certificate along with the offer.
All disputes or differences of any kind whatsoever arising out of or in connection with this contract, whether during its execution or after completion, termination, or breach thereof, shall be subject to the exclusive jurisdiction of the competent courts at New Delhi only.
The issues not covered under the tender document shall be governed by General conditions of Contract (GCC) 2022 or its latest amendments if any during entire period of contract. If any contradiction in Tender Document and GCC is observed then GCC shall prevail.
Defective parts shall only be replaced with OEM's spares. Proper invoices/delivery challan /warranty certificate etc. shall be provided by the firm to prove genuineness of spare parts.
Electrical work in connection with "Augmentation of infrastructural facilities renovation and allied works to improve maintenance facilities at Various Outpits location under Electrical RSO DLI (at ANVT, NDLS, GZB, DLI Main & TKD)
85-SRDEE-G-DLI-2026-27
85-SRDEE-G-DLI-2026-27
Open
Works - General
6 Months
Delhi, Delhi
₹0
₹1.1 L
15 Jun 2026
22 May 2026
1 Jun 2026
77 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 56,14,097 | ||
| — | 250.00 | — | — | ||
| Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLSH PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required and conforming to IS 732:2019 (reviewed in 2024) & CPWD General Specifications for Electrical Works Part-I Internal - 2023 and CPWD DSR (E&M) 2022 or latest & as per explanatory note. Group C | — | — | — | 3,52,500 | |
| — | 800.00 | — | — | ||
| Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLSH PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required of reputed make as per IS, IE rules and site requirement and conforming to IS 732:2019 (reviewed in 2024) & CPWD General Specifications for Electrical Works Part-I Internal - 2023 and CPWD DSR (E&M) 2022 or latest & as per explanatory note. Size : 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire | — | — | — | 2,11,200 | |
| — | 400.00 | — | — | ||
| Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLSH PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required of reputed make as per IS, IE rules and site requirement and conforming to IS 732:2019 (reviewed in 2024) & CPWD General Specifications for Electrical Works Part-I Internal - 2023 and CPWD DSR (E&M) 2022 or latest & as per explanatory note. Size : 2 x 4 sq. mm + 1 x 4 sq. mm earth wire | — | — | — | 1,11,600 | |
| — | 200.00 | — | — | ||
| Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLSH PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required of reputed make as per IS, IE rules and site requirement and conforming to IS 732:2019 (reviewed in 2024) & CPWD General Specifications for Electrical Works Part-I Internal - 2023 and CPWD DSR (E&M) 2022 or latest & as per explanatory note. Size : 2 x 10 sq. mm + 1 x 6 sq. mm earth wire | — | — | — | 1,08,600 | |
| — | 150.00 | — | — | ||
| Supply of ceiling rose, 3 pin conforming to IS : 371-1999 (or latest) & installation on the junction box of laid conduit including connections, testing & commissioning as per site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 and CPWD DSR (E&M) 2022 or latest & as per explanatory note. | — | — | — | 10,500 | |
| — | 50.00 | — | — | ||
| Supply of Batten/Angle Holder conforming to IS : 1258-2005 (or latest version) & installation on the junction box of laid conduit including connections, testing & commissioning as per site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 and CPWD DSR (E&M) 2022 or latest & as per explanatory note. | — | — | — | 6,050 | |
| — | 150.00 | — | — | ||
| Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required and conforming to IS 3854:2023/ IEC 60669-1, IS 14772:2020 & CPWD General Specifications for Electrical Works Part-I Internal - 2023 and CPWD DSR (E&M) 2022 or latest & as per explanatory note. | — | — | — | 66,600 | |
| — | 100.00 | — | — | ||
| Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required and conforming to IS 3854:2023, IS 14772:2020 or latest & CPWD General Specifications for Electrical Works Part-I Internal - 2023 and CPWD DSR (E&M) 2022 or latest & as per explanatory note. | — | — | — | 55,700 | |
| — | 10.00 | — | — | ||
| Supply, recessing, fixing, testing and commissioning of 25/32 A DP, 30 mA RCCB AC type confirming to IS 12640-1 & IEC 61008-1 or latest with 10KA short circuit withstand capacity complete with enclosure for water cooler conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 and CPWD DSR (E&M) 2022 or latest & as per explanatory note. | — | — | — | 27,500 | |
| — | 60.00 | — | — | ||
| Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required as per IS 11037 (reviewed in 2025) and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 and CPWD DSR (E&M) 2022 or latest & as per explanatory note. | — | — | — | 20,280 | |
| — | 60.00 | — | — | ||
| Supply, Installation, Testing and Commissioning of 1400 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal blades (almunium alloy), 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 245 Cum/Min , 350 RPM (tolerance as per IS : 374-2019),THD less than 10%, suitable for electronic regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. It shall also include the scope of supply and installation of safety cord of SS as per IS:302 Part 2 Sec-80. Dia & length of such cord shall be as per recommendation of OEM of fan and same shall be approved by railway conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 and CPWD DSR (E&M) 2025 & as per explanatory note. | — | — | — | 1,75,140 | |
| — | 20.00 | — | — | ||
| Supply, fixing, testing and commissioning of 380mm sweep, 1400 rpm (approx) propeller type exhaust fan complete in all respect as per specification and as per site requirement, including grouting of nut, bolts, washer and with the suitable fasteners conforming to IS 2312:1967 (reviewed in 2020) or latest & IS 302 or latest and other relevant IS/IEC standards and as per explanatory note. Make Bajaj, Usha, Havells, Orient or equivalent | — | — | — | 62,980 | |
| — | 20.00 | — | — | ||
| Supply, fixing, testing and commissioning of 600 mm sweep, 1200 RPM, industrial weatherproof air circulator fan complete as per IS 2312: 1967 (reviewed in 2020) or latest and as per IS, IE rule & site requirement and as per explanatory note. Make: Havells, Usha, Orient, Bajaj or equivalent | — | — | — | 1,35,860 | |
| — | 20.00 | — | — | ||
| Supply, fixing, Testing and Commissioning of 400 mm sweep BLDC wall mounted fan having Power wattage 32-35 Watt, Air delivery minimum 76 Cum/Min, suitable for 230 V, 50 Hz, single phase AC Supply and as per IS 555:1979 (reaffirmed 2020) complete & as per explanatory note. | — | — | — | 52,860 | |
| — | 10.00 | — | — | ||
| Supply, fixing, Testing and Commissioning of 250 mm sweep fresh air fan complete as per IS 2312: 1967 (reviewed in 2020) or latest and as per IS, IE rule & site requirement and as per explanatory note. Make Bajaj, Usha, Havells, Orient or equivalent | — | — | — | 12,280 | |
| — | 180.00 | — | — | ||
| Supply, fixing, testing and commissioning of LED light luminaire, having system wattage 1x18-20 watt. LED tube and inbuilt LED driver, CRCA body powder coated, complete with all mounting arrangement, accessories. CRI >= 80, SDCM (standard deviation color matching) <3. The LED based 4 ft. tube light (lamp) shall be conforming to CEE/NR's spec. No. CEE/NR/121- Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121- Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note. | — | — | — | 1,15,740 | |
| — | 12.00 | — | — | ||
| Supply, fixing, testing and commissioning of 45-50 watt LED based street light luminary with CRI >= 70, SDCM (standard deviation color matching) <5, single housing, side entry, high pressure aluminum die cast/extruded aluminum, IP 66 or better having system complete conforming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note. | — | — | — | 35,580 | |
| — | 20.00 | — | — | ||
| Supply, fixing, testing and commissioning of 90-95 W LED based street light luminary with CRI >= 70, SDCM (standard deviation color matching) <5, single housing, side entry, high pressure aluminum die cast/extruded aluminum, IP 66 or better having system complete conforming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note. | — | — | — | 1,17,760 | |
| — | 30.00 | — | — | ||
| Supply, fixing, testing and commissioning of 150 W LED based high bay light luminary with CRI >= 70, SDCM (standard deviation color matching) <5, single housing, side entry, high pressure aluminum die cast/extruded aluminum, IP 66 or better having system complete conforming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note. | — | — | — | 2,78,700 | |
| — | 225.00 | — | — | ||
| Supply, fixing, testing and commissioning of 48V, 50 Hz LED based pit light luminary with IP-66 protection, impact resistance IK10 having system wattage 22 watt complete with anti theft mounting arrangement made out of 2 mm thick CRCA sheet with anti corrosive treatment and suitable mounting as per site requirement of make Phillips, Bajaj, Havells or similar conforming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note. | — | — | — | 8,79,750 | |
| — | 15.00 | — | — | ||
| Supply, fixing, testing & commissioning of Step down single phase transformer 230V/110V or 48 V AC of 5 KVA capacity, double wound winding, input, output voltage meter, Voltage regulation 95% or above, Aluminum/ copper connector suitable for connection with 16/25/35 sq.mm aluminum cable, MCB complete with fixing arrangement, made out of 2 mm thick CRCA sheet with anti corrosive treatment, weather proof enclosure IP 65, indication lamp, foundation arrangement and anti theft arrangement as per site requirement & as per explanatory note. | — | — | — | 2,35,575 | |
| — | 225.00 | — | — | ||
| Supply, fixing, testing & commissioning of Thermoplastic PC-GFS Polycarbonate weatherproof junction box IP-67 (size 205 x 255 x 112 MM) weatherproof UV resistant, rain waterproof, temperature resistant, flame retardant suitable for termination of 4C X 25 SQMM cable with earth terminal as well as loop-in / loop-out of cable. The junction box shall fulfill the following standards IEC 6067-22:Particular requirements for connecting boxes and enclosures. IEC 60695-2-11 : Flame -retardant & Self-extinguishing. Glow Wire tested at minimum 960 degree C. IEC 60529: IP 66 / IP 67 / IP 69 degree protection as per site requirement & as per explanatory note. | — | — | — | 9,24,525 | |
| — | 5.00 | — | — | ||
| Supply, fixing, testing and commissioning of Wall mounted LT switch board suitable for 3 phases 4 wires 415 V AC supply, surface mounting/recessed double door outdoor type made up of CRCA sheet sheet with anti corrosion treatment and suitable, IP 54 phosphatised powder painted complete with 400Amp Copper Bus bar for phases and 200 Amp for Neutral, earth point, Din rail and prewired confirming to IEC 60947, Make- ABB, Siemens, L&T, Schneider, Legrand or equivalent with following items of matching make to be fixed in distribution board, confirming to IEC 61439, IE rules and site requirement. It should be rodent entry proof. It should also include well dressing and coding of circuit & as per explanatory note. 125 A 4P MCCB 35 KA= 01 No. (Incoming), 63 A 4P MCCB 35 KA= 02 Nos. (Outgoing), 32 A 4P MCCB 35 KA= 02 No. (Outgoing), 6-32A MCB SP "C" Series =06 Nos. (Outgoing), It should be rodent entry proof. It should also include well dressing and coding of circuit IP2X terminal , reversible door with 180 degree opening, cement spill protection, detachable gland at top and bottom and short link for MCBs. It should also include proper tagging on electrical wires/cables which clearly indicate the incoming point or source and outgoing point of wires/cables. | — | — | — | 4,71,660 | |
| — | 5.00 | — | — | ||
| Supply, fixing, testing and commissioning of LT distribution board surface mounting/recessed double door outdoor type made up of CRCA sheet sheet with anti corrosion treatment and suitable, IP 43 phosphatised powder painted complete with neutral link, earth point, Din rail and prewired confirming to IEC 60947, Make- ABB, Siemens, L&T, Schneider, Legrand or equivalent with following items of matching make to be fixed in distribution board, confirming to IEC 61439, IE rules and site requirement. It should be rodent entry proof. It should also include well dressing and coding of circuit & as per explanatory note. 63 A 4P RCBO 100 mA= 01 No. (Incoming) 6-32A MCB SP "C" Series = 18 Nos. (Outgoing) It should be rodent entry proof. It should also include well dressing and coding of circuit IP2X terminal , reversible door with 180 degree opening, cement spill protection, detachable gland at top and bottom and short link for MCBs. It should also include proper tagging on electrical wires/cables which clearly indicate the incoming point or source and outgoing point of wires/cables. | — | — | — | 57,930 | |
| — | 5.00 | — | — | ||
| Supply, fixing, testing and commissioning of LT distribution board surface mounting/recessed double door outdoor type made up of CRCA sheet sheet with anti corrosion treatment and suitable, IP 43 phosphatised powder painted complete with neutral link, earth point, Din rail and prewired confirming to IEC 60947, Make- ABB, Siemens, L&T, Schneider, Legrand or equivalent with following items of matching make to be fixed in distribution board, confirming to IEC 61439, IE rules and site requirement. It should be rodent entry proof. It should also include well dressing and coding of circuit & as per explanatory note. 40 A 4P RCBO 30/100 mA= 01 No. (Incoming) 6-32A MCB SP "C" Series =09 Nos. (Outgoing) It should be rodent entry proof. It should also include well dressing and coding of circuit IP2X terminal , reversible door with 180 degree opening, cement spill protection, detachable gland at top and bottom and short link for MCBs. It should also include proper tagging on electrical wires/cables which clearly indicate the incoming point or source and outgoing point of wires/cables. | — | — | — | 33,895 | |
| — | 600.00 | — | — | ||
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground as per IS 1255 (reviewed in 2016) or latest including excavation, sand cushioning, protective covering and refilling the trench [size width- not less than 35 c m and depth- 75 to 100 cm] etc. as required as per detail drawing approved by competent authority. In case of any demolition of PCC, RCC, road, wall surface etc. the contractor should ensure repairing of the same on own expenses as per site requirement and satisfaction of railway representative and conforming to CPWD General Specifications for Electrical Works Part-II External - 2023 and CPWD DSR (E&M) 2022 or latest & as per explanatory note. Upto 35 sq. mm | — | — | — | 2,11,200 | |
| — | 480.00 | — | — | ||
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground as per IS 1255 (reviewed in 2016) or latest including excavation, sand cushioning, protective covering and refilling the trench [size width- not less than 35 cm and depth- 75 to 100 cm] etc. as required as per detail drawing approved by competent authority. In case of any demolition of PCC, RCC, road, wall surface etc. the contractor should ensure repairing of the same on own expenses as per site requirement and satisfaction of railway representative and conforming to CPWD General Specifications for Electrical Works Part-II External - 2023 and CPWD DSR (E&M) 2022 or latest & as per explanatory note. Above 35 sq. mm and upto 95 sq. mm | — | — | — | 2,02,080 | |
| — | 300.00 | — | — | ||
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground as per IS 1255 (reviewed in 2016) or latest including excavation, sand cushioning, protective covering and refilling the trench [size width- not less than 35 cm and depth- 75 to 100 cm] etc. as required as per detail drawing approved by competent authority. In case of any demolition of PCC, RCC, road, wall surface etc. the contractor should ensure repairing of the same on own expenses as per site requirement and satisfaction of railway representative and conforming to CPWD General Specifications for Electrical Works Part-II External - 2023 and CPWD DSR (E&M) 2022 or latest & as per explanatory note. Above 95 sq. mm and upto 185 sq. mm | — | — | — | 1,40,100 | |
| — | 400.00 | — | — | ||
| Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground as per IS 1255 (reviewed in 2016) or latest in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench [size width- not less than 55 cm and depth-(75-100) cm] etc. as required as per detail drawing approved by competent authority. In case of any demolition of PCC, RCC, road, wall surface etc. the contractor should ensure repairing of the same on own expenses as per site requirement and satisfaction of railway representative and conforming to CPWD General Specifications for Electrical Works Part-II External -2023 and CPWD DSR (E&M) 2022 or latest & as per explanatory note. Upto 35 sq. mm | — | — | — | 1,15,200 | |
| — | 160.00 | — | — | ||
| Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground as per IS 1255 (reviewed in 2016) or latest in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench [size width- not less than 55 cm and depth-(75-100) cm] etc. as required as per detail drawing approved by competent authority. In case of any demolition of PCC, RCC, road, wall surface etc. the contractor should ensure repairing of the same on own expenses as per site requirement and satisfaction of railway representative and conforming to CPWD General Specifications for Electrical Works Part-II External -2023 and CPWD DSR (E&M) 2022 or latest & as per explanatory note. Above 35 sq. mm and upto 95 sq. mm | — | — | — | 49,120 | |
| — | 100.00 | — | — | ||
| Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground as per IS 1255 (reviewed in 2016) or latest in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench [size width- not less than 55 cm and depth-(75-100) cm] etc. as required as per detail drawing approved by competent authority. In case of any demolition of PCC, RCC, road, wall surface etc. the contractor should ensure repairing of the same on own expenses as per site requirement and satisfaction of railway representative and conforming to CPWD General Specifications for Electrical Works Part-II External -2023 and CPWD DSR (E&M) 2022 or latest & as per explanatory note. Above 95 sq. mm and upto 185 sq. mm | — | — | — | 33,600 | |
| — | 1000.00 | — | — | ||
| Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required as per IS 1255 (reviewed in 2016) or latest. In case of any demolition of PCC, RCC, road, wall surface etc. the contractor should ensure repairing of the same on own expenses as per site requirement and satisfaction of railway representative and conforming to CPWD General Specifications for Electrical Works Part-II External - 2023 and CPWD DSR (E&M) 2022 or latest & as per explanatory note. Upto 35 sq. mm (clamped with 1mm thick saddle) | — | — | — | 59,000 | |
| — | 160.00 | — | — | ||
| Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required as per IS 1255 (reviewed in 2016) or latest. In case of any demolition of PCC, RCC, road, wall surface etc. the contractor should ensure repairing of the same on own expenses as per site requirement and satisfaction of railway representative and conforming to CPWD General Specifications for Electrical Works Part-II External - 2023 and CPWD DSR (E&M) 2022 or latest & as per explanatory note. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) | — | — | — | 22,240 | |
| — | 100.00 | — | — | ||
| Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required as per IS 1255 (reviewed in 2016) or latest. In case of any demolition of PCC, RCC, road, wall surface etc. the contractor should ensure repairing of the same on own expenses as per site requirement and satisfaction of railway representative and conforming to CPWD General Specifications for Electrical Works Part-II External - 2023 and CPWD DSR (E&M) 2022 or latest & as per explanatory note. Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) | — | — | — | 16,900 | |
| — | 25.00 | — | — | ||
| Earthing with 40 mm dia GI pipe class 'B' 4.5 meter long earth electrode as per IS:3043 (or latest version) including construction of masonry enclosures with hinged cover plate of cast iron with locking arrangement (approx. size 400 mm x 400mm) on top, and water pipe etc. with charcoal/coke and salt as required and provision of earth plate, connections from earth electrode to switch gear/pole as per drawing & as per explanatory note. | — | — | — | 1,43,775 | |
| — | 125.00 | — | — | ||
| Supplying and laying 25 mm X 5 mm G.I strip confirming to relevant IS as per IS:3043 (or Latest version), fixing on surface or as per site condition, clamping or fixing with suitable arrangement as per site requirement, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required & as per explanatory note. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm) | — | — | — | 19,625 | |
| — | 300.00 | — | — | ||
| Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required as per IS:3043 (or Latest version) & as per explanatory note. | — | — | — | 17,100 | |
| — | 2.00 | — | — | ||
| Supply of heavy duty aluminium stool type folding ladder having "C" shapes section of size 16"x12" on the top suitable for height upto 12 feet complete similar to Sumer Make design no. AL-201/8818 (Heavy duty) or equivalent & as per explanatory note. | — | — | — | 23,392 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderDocument.pdf
ATTACHMENT
SpecialConditionsofContract.pdf
ATTACHMENT
ExplanatoryNote.pdf
ATTACHMENT
GCC-2022-ACS10_merged.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo.11.pdf GCC ACS No 11
ATTACHMENT
TECHSPEC-I.pdf
ATTACHMENT
TECHSPEC-II.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo.11.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .