| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.5 LAccepted-AOC | ₹26.5 L Quoted ₹27.9 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹30.1 L+₹2.2 L (7.85%)Rejected-Finance 307 SADAR BAZAR LUCKNOW UP 226002 | LUCKNOW | UTTAR PRADESH | 226002 | ₹30.1 L+₹2.2 L (7.85%) | L2 | Rejected-Finance Not being lowest bidder |
| 3 | L3₹30.3 L+₹2.5 L (8.79%)Rejected-Finance 301 TULSI TOWER KHADAKPADA KALYAN THANE MAHARASHTRA 421301 | THANE | MAHARASHTRA | 421301 | ₹30.3 L+₹2.5 L (8.79%) | L3 | Rejected-Finance Not being lowest bidder |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
26 Jul 2021, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR/MAINT AND IMPROVEMENT OF LT FEEDER PILLAR BOX/LT PANELS, BUS BAR PANELS, LT SWITCH GEAR/MCCB AND OTHER CONNECTED WORK EAST OF MG ROAD AREA UNDER GE E/M LUCKNOW
2021_MES_455552_1
GE/EM/LKO/EXT(ELECT)/T-32 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
Class D or above category b (i)
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹90,000
Yes
13 Aug 2021
29 Jun 2021
28 Jul 2021
29 Jun 2021
26 Jul 2021
13 Jul 2021
Amount
Supply, installation, testing and commissioning out door type cubical panel board outer shell made out of 3.15 mm thick MS sheet and inner shell made out of 2 mm thick MS sheet and MS angle section 50x50x6 mm on PCC 1:2:4 type B-1 platform 40 cm above the ground level and 45 cm below the ground level, frame factory fabricated with front and back openable double door system lockable/openable by Keys having chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air “U” type gasket shall be used to make the outer shell completely vermin proof .suitable for 3 phase 4 wire 415 Volt, 50 Hz, CPRI approved, 35 MVA rupturing capacity at 415 Volts factory fabricated having modern fabrication and testing process which includes seven tank pretreatment process comprising of degreasing, rinsing, de-rusting, rinsing, phosphatising, rinsing and passivation followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93. The TPN busbar shall be insulated with colour coaded heat shrinkable sleeve and shall be mounted on suitable size "F" class insulator at an interval not more than 250 mm through out the length of theTPN busbar. The cubicle incomer MCCB as well as outgoing shall have aluminium TPN extension links of current carrying
Contd..... capacity not less than 1.5 times the rated capacity of individual feeder. The extension links shall not be less than 300mm long supported on suitable size "F" class insulator. All inter connections between the main busbar as well as outgoing feeder shaal be carried out with TPN aluminium busbar of rating not less than 1.5 times rated capacity of individual outgoing feeders & should be insulated with heat shrinkable PVC sleeves.comprising of the following:- a) The TPN busbar 600 Amp duly plated copper busbar fitted in cascaded moulding. b) Incoming MCCB 400 Amps 36 kA, 415 volts, FP adjustable thermal setting (80 to 100 %) type - 01 Nos c) Ongoing MCCB 250 Amps 25 kA, 415 volts, FP - 01 Nos d) Ongoing MCCB 200 Amps 25 kA, 415 volts, FP - 01 Nos e) Ongoing MCCB 100 Amps 25 kA, 415 volts, FP - 02 Nos f) Provn of blank compartment for future uses, 415 volts, FP - 01 Nos g) Voltage/Ampere/Frequency meter multi functional meter - 01 No f) LED indicator lamp RYB - 01 Set of three
All as per item No 01 above but with following a) The TPN busbar 400 Amp duly plated copper busbar fitted in cascaded moulding. b) Incoming MCCB 250 Amps 36 kA, 415 volts, FP adjustable thermal setting (80 to 100 %) type - 01 Nos c) Ongoing MCCB 100 Amps 25 kA, 415 volts, FP - 04 Nos d) Ongoing MCCB 63 Amps 25 kA, 415 volts, FP - 01 Nos e) Change over switch 200 Amp on load type, 415 volts, FP - 01 Nos f) Provn of blank compartment for future uses, 415 volts, FP - 01 Nos g) Voltage/Ampere/Frequency meter multi functional meter - 01 No h) LED indicator lamp RYB - 01 Set of three
All as per item No 01 above but with following a) The TPN busbar 400 Ampduly plated copper busbar fitted in cascaded moulding. b) Incoming MCCB 250 Amps 36 kA, 415 volts, FPadjustable thermal setting (80 to 100 %) type - 01 Nos c) Ongoing MCCB 100 Amps 25 kA, 415 volts, FP - 01 Nos d) Ongoing MCCB 160 Amps 25 kA, 415 volts, FP - 03 Nos e) Provn of blank compartment for future uses, 415 volts, FP - 01 Nos f) Voltage/Ampere/Frequency meter multi functional meter - 01 No g) LED indicator lamp RYB - 01 Set of three
All as per item No 01 above but with following a) The TPN busbar 400 Amp duly plated copper busbar fitted in cascaded moulding. b) Incoming MCCB 250 Amps 36 kA, 415 volts, FPadjustable thermal setting (80 to 100 %) type - 01 Nos c) Ongoing MCCB 160 Amps 25 kA, 415 volts, FP - 02 Nos d) Ongoing MCCB 100 Amps 25 kA, 415 volts, FP - 02 Nos e) Provn of blank compartment for future uses, 415 volts, FP - 01 Nos f) Voltage/Ampere/Frequency meter multi functional meter - 01 No g) LED indicator lamp RYB - 01 Set of three
Supply, installation, testing and commissioning out door type busbar panel board made out of 3.15 mm thick MS sheet and MS angle section 40x40x5 mm on PCC 1:2:4 type B-1 platform 40 cm above the ground level and 45 cm below the ground level, frame factory fabricated with front and back openable double door system lockable/openable by Keys having chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricated having modern fabrication and testing process which includes seven tank pretreatment process comprising of degreasing, rinsing, de-rusting, rinsing, phosphatising and passivation followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93. a) TPN, Aluminium bus bar 200 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. b) Incoming MCCB 160 Amps 36 KA, 415 Vots, 50 Hz, FP. – 1 No c) LED Indicator lamp RYB - 01 set of three.
Fixing only On load changeover (open construction )manually operated 4 pole switch disconnector fuse with position I-O-II with with back up HRC fusees fitted in phases, 100 /200 Amps four pole, fixed to panels with suitable size clamps, nuts, bolts and washer, including necessary connection ,testing complete all as specified and directed by Engineer in charge (Note : Mtrl will be issued under Schedule 'B' free for fixing)
Fixing only On load changeover manually operated 4 pole switch in sheet metal enclosure disconnector fuse with position I-O-II with with back up HRC fusees fitted in phases, 100 /200 Amps four pole, fixed to wall/panels with suitable size clamps, nuts, bolts and washer, including necessary connection ,testing complete all as specified and directed by Engineer in charge (Note : Mtrl will be issued under Schedule 'B' free for fixing)
Fixing in repairs off load changeover manually operated 4 pole switch , 100/63 Amps four pole, in sheet metal enclosure fixed to wall/panels with suitable size clamps, nuts, bolts and washer, including necessary connection ,testing complete all as specified and directed by Engineer in charge (Note : Mtrl will be issued under Schedule 'B' free for fixing)
Supply & fixing in replacement Contactor TP 32 Amp 1NO+1NC,415 V complete all as specified and directed by Engineer in charge
Supply & fixing in replacement Contactor TP 63 Amp 1NO+1NC,415 V complete all as specified and directed by Engineer in charge
Disconnecting all existing electrical connection from panel ,taking out unserviceable MCCB and cable from LT panel Board and fixing, only ,connecting and testing of MCCB 63 to 160 Amp 3/4 pole with suitable size of cable lugs/thimble complete incl all electrical connection with making good the damaged surface complete all as specified and directed by Engineer in charged. (Note : Mtrl will be issued under Schedule 'B' free for fixing)
Disconnecting all existing electrical connection from panel ,taking out unserviceable MCCB and cable from LT panel Board and fixing, only ,connecting and testing of MCCB 200 to 400 Amp 3/4 pole with suitable size of cable lugs/thimble complete incl all electrical connection with making good the damaged surface complete all as specified and directed by Engineer in charge. (Note : Mtrl will be issued under Schedule 'B' free for fixing)
M&L for painting on old painted surface of LT Panel/Feeder Piller Box by brushing after cleaning stain & grease spot with thinner and sand papar and painting the cleaned surface with synthetic enamel paint as existing colour to acheive good finish by applying two coat paint by spray painting machine carefully after disconnection of power supply and covering the meters, indicators, relays and switches to prevent fall of paint drop on them & including writing, numbering, letter etc with white paint on newly painted surfaces complete all as specified and directed by Engineer in charge
Supply & Fixing in repair MCCB Distribution Board TPN double door with and including 415 volts with 200 Amps bus bar, factory made 4 way flush type protection class IP-54 of Legrand or equivalent of other specified make with and including MCCB 100 Amps, FP, 16 kA - 1No. of legrand or equivalent of other specified make as incomer and MCB SP, 63 Amps, 10 kA, 'C' curve -12 Nos, as outgoing including grouting the DB flush with walls , making good disturbed surfaces complete all as specified and directed by Engineer in charge
Supply and fixing in repairs MCCB TP 63 Amps 16 KA, 415 Volts AC, 50 Hz, complete with in sheet metal enclosere of 1.6 mm thick MS sheet with powder coat painted including connecting with existing system and cabling network including making good disturbed surfaces complete all as specified and directed by Engineer in charge
Fixing only in replacement Isolator 100/63 Amp Amps, 3/4 pole, , 415 volts complete all as specified and directed by Engineer in charge (Note : Mtrl will be issued under Schedule 'B' free for fixing)
M&L in repairs for submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated multistranded copper conductor cable 2x6 sqmm & 1x4 sqmm as earth wire with and including surface PVC casing caping of size not less than 20 mm complete all as specified and directed by Engineer in charge
M & L for maintenance of feeder pillar/LT panel indoor/outdoor type Panel by cutting corroded MS lid from LT panel, and weilding the same with 2 mm thick MS sheet in any desired shape including removing the carbonized/melted sparked thimbles, cleaning the carbonized bus bar making cable ends clean and replacement of following unserviceable parts with new nut bolts and washer complete all as specified and directed by Engineer in charge
Supply of Multifunction meter complete all as specified and directed by Engineer in charge
Supply of LED Indicator lamps complete all as specified and directed by Engineer in charge
Supply of Burnt/missing Aluminium busbars of 200 Amp complete all as specified and directed by Engineer in charge
Supply of Copper wiring for connection 4sq mm single core complete all as specified and directed by Engineer in charge
Supply of Powder coated CRCA sheet metal enclosure duly painted and fabricated all as reqd at site complete all as specified and directed by Engineer in charge
Supply & fixing ,Laying , jointing and testing LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 16 sqmm cross sectional area, 2 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers complete all as specified and directed by Engineer in charge. inclding taking out old unsv/ faulty LT under ground cable of any size and capacity and deposited the same in MES store yard. Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately
All as per item 24 above but of size 16 Sqmm 4 core
All as per item 24 above but of size 25 Sqmm 4 core
All as per item 24 above but of size 35 Sqmm 3.5 core
All as per item 24 above but of size 50 Sqmm 3.5 core
All as per item 24 above but of size 70 Sqmm 3.5 core
All as per item 24 above but of size 95 Sqmm 3.5 core
All as per item 24 above but of size 120 Sqmm 3.5 core
All as per item 24 above but size 185 sq mm 3.5 core
Laying only old serviceable LT underground cable after removing of defects any type/size in trenches / road crossing /through pipes pat drains/ducts/floors/along poles/walls/ceilings complete all as specified and directed by Engineer in charge Note - excavation and earth work will be measured and paid seprately in appropriate item.
Hiring of cable fault detector , to detect exact position of fault for XLPE/PVC/LT/HT Cable , 1100/11000 volts, grade Heavy duty aluminium conductor of any size including to and fro transporting charges etc. complete all as specified and directed by Engineer in charge
Dismconnecing the existing cable from Panel/ Pole, preparing the end for jointing including all earth work, Supply and fixing straight through heat shrinkable joint suitable for LT XLPE cable of Size 3.5 Core 16 to 50 Sqmm complete all as specified and directed by Engineer in charge. Make: Denson, Mseal, cabseal
As per item No 35 above but Size 70 to 120 Sqmm
As per item No 35 above but Size 150 to 400 Sqmm
Disconnecting the existing cable from Panel / Pole, preparing the end for jointing including all earth work, Supply and fixing Cable end termination heat shrinkable joint inclding sleeves suitable for LT XLPE cable of size 3.5 core 16 to 50 sq mm complete all as specified and directed by Engineer in charge Make: Denson, Mseal, cabseal
As per item No 38 above but Size 70 to 120 Sqmm
As per item No 38 above but Size 150 to 400 Sqmm
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode 32X6 mm GI earth strip by means of bolts, nuts check nuts and washers of GI or steel and connecting to earthing test point, main switch board, testing on completion including PCC cover and frame, PCC (1:3:6) type C-2 as in earthing pit, MS funnel with wire mesh GI pipe 20 mm dia light grade for watering and GI pipe 20 mm dia light grade for the protection of GI wire from earth pit to earth point complete including necessary excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50 m all as specified as shown in electrical plate No 5 SSR Part-I. PCC chamber shall be constructed at least one metre away from the earth pit and GI pipe fittings for watering shall be provided up to chamber and cost of the same is deemed to be included in the rate of earthing.
Excavation in trenches in soft/loose soil not exceeding 1.5 m wide and exceeding 1.5 m, but not exceeding 3.00 m, in depth for foundations laying of cable etc. and getting out complete all as specified and directed by Engineer in charge.
Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and directed by Engineer in charge.
Removing excavated material ( soils) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer in charge.
Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete all as specified and directed by Engineer in charge.
M&L laying well burnt old size bricks, sub class "B" bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified and directed by Engineer in charge.
Boring / drilling (Horizontly ) manually under existing road Max 10 M in width ) suitable for passing GI tubing 40 to 100 mm bore complete all as specified and directed by Engineer in charge.
S&F Mild steel galvanized tubes light grade ISI marked 40mm bore laid in trenches / road crossing/ fixed to pole /walls/path/drain/floor etc complete all as specified and directed by Engineer in charge.
All as per item 48 above but 50 mm size complete
All as per item 48 above but 80 mm size complete
Supply, install, testing and commissioning of meter panel board (900X 80X20 CM) Factory fabricated in door type made out of 2.0 mm thick sheet metel enclosure fixed on wall with four nos old fast suitable for operation on 3 phase 4, wire, 440 volts 50 HZ sysytem with hinged panel doors & locking arrangements incl required nos of holes with chromium plated brass cable entry and exit complete including necessary internal wiring with PVC insulated multistrand copper conductor singhl core FRLS cable of size 10 sqmm and spray painted grey hammer tone with one coat of red oxide primer and two coats of synthetic enamel paint of grey or any other approved colour, including connection and housing with following accessaries, complete all as specified and directed by Engineer in charge. b) MCCB 100 Amps 16 KA, 415 Vots, 50 Hz, FP. – 1 No c) MCB DP 40Amps 10 KA, 415 Vots, 50 Hz, FP. – 6 Nos d) Aluminium bus bar with insulated strip of capacity 200 Ampsce (d)Space of Electric meter. with transparent glass box-05 Nos e) LED Indicator lamp RYB - 01 set of three.
S&F MS Junction Box made of 1.6 mm thick MS sheet of size 300mmx200mmx150mm complete with front openable hinged cover and locking arrangements with 4 Nos aluminium bas bar 100 Amps, mounted on porcelin insulator including M&L for MCB SP 10-1No, fixed on box in Din rail complete with electrical connection fixed to pole with suitable size FI clamp nut bolts and washer including duly painted with powder coated paint complete all as specified and directed by Engineer in charge.
Surface dressing/ cleaning of surrounding area of street light pole area including removing of tree branches complete all as specified and directed by Engineer in charge.
M/s Vatsh Raj and co
Diamond Electric Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .