Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical 538 RAJPOOT COLONY SHIVAJI NAGAR JHANSI | JHANSI | JHANSI | UTTAR PRADESH | Accepted-Technical Accepted |
| 2 | Accepted-Technical NEAR DAUPANJALI SCHOOL FARIDPUR ROHANA VARANASI 225879 | VARANASI | VARANASI | UTTAR PRADESH | 225879 | Accepted-Technical Accepted |
| 3 | Accepted-Technical | Accepted-Technical Accepted |
| 4 | Accepted-Technical | Accepted-Technical Accepted |
Tender Value
₹1.5 Cr
EMD Value
₹2.9 L
Closing Date
20 Mar 2026, 12:00 pmClosed
Executive Engineer Incharge
Commissionary Campus Opp. Circuit house Near Panchtantra park, Jhansi
Pradhanmantri Awas Yojna ke Antargat Gram Karari me Nirmit 756 Awason wa Overhead Tank Banaye jane ka Nirman Karya.
2026_UPJDA_1123943_1
2095/JDA/25-26
Open Tender
Civil Works
Percentage
180 days
Office of Jhansi Development Authority
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,900
Yes
Secretary
₹2.9 L
Yes
17 Apr 2026
11 Mar 2026
20 Mar 2026
11 Mar 2026
20 Mar 2026
11 Mar 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Name of Work: Pradhanmantri Awas Yojna ke Antargat Gram Karari me Nirmit 756 Awason wa Overhead Tank Banaye jane ka Nirman Karya. Note :-(1)- GST Excluded on the aforesaid work. | |||||
| 1.01 | R.C.C Overhead Tank- Supply of all material labour T&P etc.for complete construction of R.C.C Over head tank of following capacity and stagiing above ground level with main components incluiding cost of soil testing and assuming bearing capacity of soil as 8 MT with supply of design and drawings.All the water retaining components of OHT shall be casted in M-30 concrete and minimum grade of concrete of foundation and staging should be M-25 with approved cement coarse sand and stone grit as per I.S 11682 and I.S 456 seismic effects and wind load should be taken into consideration as per I.S 1893 for earthquake resistance and I.S 875 part-III for wind load on structure and incluiding 1M wide RCC staircase 1m wide R.C.C M30 balcony M.S.ladder made of 50x50x6 mm angles section and 20 mm plain M.S bars with hand rails of 20mm medium class G.I p[ipes one aluminium ladder inside the tak from top dome R.C.C. railing with 20mm dia medium class G.I.(in 3 rows) on both sides of stair case supported on 50x50x6mm M.S angle section spaced at intervals not more than 1.5m proper ventilator at top dome in circular shape of 1.2 m dia water level indicator fabricated with sensor connecting to automation lightening conductor as per I.S.S.2309 or its latest amendment of latest electricity rules consisting of proper elevation rod with 5 or more fork points as prescribed in ISS 2309-1969 and ISS 3013-1966 C.I. manhole of min 60x60 cm size with locking arrangement supply fixing jointing D.I.D/F pipes of appropriate size with D.D/F special conforming to IS 8329/2000 as vertical pipes for inlet,outlet,overflow and waashout as per latest / relevant I.S specification with all jointing material for proper completion of work,Construction of bed blocks in 1:2:3 PCC with cement ,coarse sand and approved stone grit ,construction of washout / overflow chamber for sluice /butter fly valves as per departmental drawing supply of 200 mm dia PVC pipes as per I.S.- 4985/2000 for disposal of water from overflow and washout chamber to suitable point outside the water compound paintings of all concrete surface and steel pipe works with three coats of approved cement and anticorrosive paints.
500 KL 14 M Staging (JAL NIGAM SOR.30.00+
30.21) | 1 | Job | 75,90,000 | ₹75,90,000 |
| 2.01 | add for 6m staging | 1 | job | 7,27,200 | ₹7,27,200 |
| 3.01 | Sluice valve - 125 mm dia for washout and overflow(JLN SOR.34.05) | 1 | Nos | 16,900 | ₹16,900 |
| 4.01 | Scour valve 150 mm dia (JLN SOR.34.10) | 1 | Nos | 19,500 | ₹19,500 |
| 5.01 | Pressure release valve 80mm dia (JLN SOR.35.01) | 1 | Nos | 54,219 | ₹54,219 |
| 6.01 | Supply and installation testing of single/doble ball type air valve conforming to latest/relevant I.S. (150 mm dia) (JLN SOR.36.04) | 1 | Nos | 41,024.88 | ₹41,024.88 |
| 7.01 | Supply of following sizes (D.I) pipes for rising main distribution system conforming to latest/relevant I.S. 8329/2000 specification with all jointing materials such bas specials conforming to latest /relevant I.S specification,suitable for D.I pipes as per I.S-239/2000 AND IS 8329/2000 or their latest amendment incluiding F.O.R destination and all taxes and insurance etc.with loading ,unloading and careting up to site of work, also incluiding testing of pipe lines and cutting of pipes for making up the length but excluding the cost of trenches and laying true to alignment and gradient and jointing etc.complete (incluiding testintg of pipes for making up the length but excluiding the cost of trenches).all complete as per instruction of Engineer-in-charge. 125mm dia DI K9 Pipe (JAL NIGAM SOR.32.05) | 200 | RMT | 1,425.07 | ₹2,85,014 |
| 8.01 | Provide all material,labour ,T&P etc complete and constructed Bye-pass chamber for pump house (100(L)x1000(W)x1150(H)mm drawing (drawing no. D-3) and as per the specification for civil works given in the bid document,incluiding supply of all materials,labour and T&P etc,complete as per instruction of Engineer -in charge. (JAL NIGAM SOR.29.00) | 1 | Nos | 20,400 | ₹20,400 |
| 9.01 | Sluice valve chamber (masonry Type) - dia upto 200 mm ‐ 1000 (L) x 1200 (W) x 1300 (H) mm (JAL NIGAM SOR.38.01) | 2 | Nos | 34,000 | ₹68,000 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.84 MB
BOQ_2094268.xls
BOQ • 0.52 MB
docum.pdf
Tender Documents • 1.97 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .