Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.4 LAccepted-AOC 5B FF NAND VIHAR AZAD NAGAR NEAR GODARA PETROL PUMP HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹33.0 L+₹4.6 L (16.2%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹39.2 L+₹10.7 L (37.7%)Rejected-Finance 25 25 SADAR BAZAR JALANDHAR CANTT | JALANDHAR | JALANDHAR | PUNJAB | L3 | Rejected-Finance L3 |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
9 Apr 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (East) Jalandhar Cantt
Garrison Engineer (East) Jalandhar Cantt
REPAIR MAINT OF CERTAIN EM WORKS AND DAY TO DAY MAINT OF ELECTRIC WORKS FOR CERTAIN BLDGS OF ZONE A AND ZONE B UNDER AGE E/M OF GE (EAST) JRC
2025_MES_695396_2
GE/JULL/ET-73/2024-25
Open Tender
Civil Works
Item Rate
335 days
Jalandhar Cantt
As per tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer (East) Jalandhar Cantt
₹1 L
27 May 2025
20 Mar 2025
12 Apr 2025
20 Mar 2025
9 Apr 2025
25 Mar 2025
Amount
Note for Srl item No 2 to 47 : Contractor will get make and sample approval of items reqd to be replaced mentioned at Sr No 2 to 47 and will hand over 100% qty as per Note (a) and (b) below after commencement of work to JE incharge with all PV & TC to ensure availbility when reqd during currency of contract and these items/ material will be issued by JE E/M daily in complaint cell on actual assessment of complaints to replace the defective part and for accounting of items. The contractor will maintain register regarding details of daily complaints recd, pending, rectified, items replaced on daily basis duly signed by contractor, JE etc. Note :- (a) Contractor has to provide 50% qty of all items to JE in Charge within 15 days of work order placing. A recovery of Rs 200/- per day shall be levied in case of contractor fails to procure and handed over said qty. (b) Contractor has to provide 50% qty of all items to JE in Charge within 45 days of work order placing. A recovery of Rs 250/- per day shall be levied in case of contractor fails to procure and handed over said qty.
Attending day to day complaints of no supply in light circuit or power circuit due to burning/disconnecting of any wire i.e. neutral/ phase, loose connection at switch, socket, ceiling rose, MCB and tripping of MCB complete incl diagnosing, rectification of fault, any petty repair required to restore the electric supply for checking of existing electrical items for continuous electric supply including carrying out minor repairs such as changing of fuse, small pieces of wires etc, carrying out repairs such as tightening of loosen electric connections, nuts, bolts screws in switches, sockets, switch board, ceiling fans/ exhaust fans etc., required to make the circuit functional during 0900 Hrs to 1700 Hrs by deploying electrician alongwith helper including necessary tools complete all as specified and directed. Notes:- (a) Repairs/ faults in any one quarter upto 10 points in one circuit shall be considered as one complaint (one measuring unit for payment) even if repair is involved in more than one light point or fitting.
(b) Number of complaints may vary day to day. Contractor shall quote his rates accordingly. (c) In case of failure on the part of contractor for attending complaints a penalty shall be imposed and recovered as specified in Particular Specifications. (d) Contractor shall ensure that the deployed electrician & helper will carry all T&P, functional and live mobile phone while on duty and will be on contact with JE/ Engineer-in-Charge without any extra cost payable to contractor. (e) Contractor shall be responsible for collection of all ON LINE, off line/ telephonic complaints and handing over the same to JE E/M after rectification duly signed by user with details of stores fixed to put the status ON LINE after attending/ complete of the job on the same day. (f) Supply, Fixing & Replacement of electric fittings/ fixtures MCBs replaced shall be measured separately under relevant items of Sch. (i) No of Electircian & helpers - 3 Nos Electrician +3 Nos Helpers (rates are deemed to be included in quoted rate) (ii) 80 % of materials will be kept under the custody of JE concern. (iii) Penality for non attending of complaints within 24 hours shall be Rs. 250/- per complaint. (iv) No of menpower to be deployed separately for each area i.e. Zone 'A', Zone 'B' & Zone 'c"
Supply and fixing in repairs switch piano flush type, 5 Amps, 240 Volt AC single pole, one way complete including taking down existing old UNSV all as specified. Note for Ser Item No. 02 to 47:- (a) Contractor has to provide 50% qty of all items to JE in Charge within 15 days of work order placing. A recovery of Rs. 200/- per day shall be levied in case contractor fails to procure and handed over said qty. (b) Contractor has to provide 50% qty of all items to JE in Charge within 45 days of work order placing. A recovery of Rs. 250/- per day shall be levied in case contractor fails to procure and handed over said qty.
Supply and fixing in repairs bell push switch flush type 5 Amps, SP, 240 volts including taking down existing bell complete all as specified
Supply and fixing in repairs socket outlet multipurpose 3 in 1, 6 pin, 5 & 15 Amps, flush type including taking down existing socket complete all as specified
Supply and fixing in repairs socket out let 5 Amp, 5 pin flush type including taking down existing socket complete all as specified.
Supply and fixing in repairs switch piano flush type, 5 Amps, 240 Volt AC single pole, two way including taking down existing switch complete all as specified.
Supply and fixing in repairs switch piano flush type, 15 Amps, 240 Volt AC single pole, one way including taking down existing complete all as specified.
Supply and fixing in repairs bell electric AC (Ding Dong) 240 volt SP including taking down existing bell complete all as specified
Supply and fixing in repairs lamp holder insulated body with back plate suitable for batten fittings including taking down existing lamp holder complete all as specified.
Supply and fixing in repairs fan step regulator 5 speed, electronic type, single phase, (socket size) including connection complete after dismantling/ removing unserviceable regulator all as specified.
Supply and fixing in replacement ceiling rose surface type bakelite 65 x 50mm three terminal including taking down complete all as specified and directed. Make for Item S No 2 to 11 : GOLDMEDAL/ REO/ ANCHOR
Supply and fixing in replacement FRLS PVC insulated unsheathed multi stranded copper conductor of size 1.5 Sqmm single core complete including taking down existing wire any type all as specified.
Supply and fixing in replacement FRLS PVC insulated unsheathed multi stranded copper conductor of size 2.5 Sqmm single core complete including taking down existing wire any type all as specified.
Supply and fixing in replacement FRLS PVC insulated unsheathed multi stranded copper conductor of size 4 Sqmm single core complete including taking down existing wire any type all as specified.
Supply and fixing in repair energy saving bulk head light luminaire with opal diffuser LED 9 watt min or next higher wattage available 6000 K, power factor more than 0.90, IP-65 class-I protection with high efficiency BIS marked LED electronic driver, surge protection 2 KV, operative on 140 volts to 270 volts AC supply complete prewired, connecting and testing complete all as specified and directed.
M&L for replacement of sub main wiring with two run of single core FRLS PVC insulated unsheathed multistranded copper conductor cable of 6 Sqmm drawn through in and including PVC rigid non existing conduit with all fittings including earth continuity FRLS PVC insulated unsheathed multistranded copper conductor cable 6.0 Sqmm PVC insulated with green insulation with any type of civil wk involved complete all as specified. NOTE:Two run of 6 sqmm wire and one run of 6 sqmm wire as earth wire shall be measured as one unit.
M&L for replacement of sub main wiring with two run of single core FRLS PVC insulated unsheathed multistranded copper conductor cable of 4 Sqmm drawn through existing conduit with all fittings including earth continuity FRLS PVC insulated unsheathed multistranded copper conductor cable 4.0 Sqmm PVC insulated with green insulation complete all as specified. NOTE:Two run of 4 sqmm wire and one run of 4 sqmm wire as earth wireshall be measured as one unit.
M&L for replacement of sub main wiring with Four run of single core FRLS PVC insulated unsheathed multistranded copper conductor cable of 6 Sqmm drawn through in and including PVC rigid existing conduit with all fittings including earth continuity FRLS PVC insulated unsheathed multistranded copper conductor cable 6.0 Sqmm PVC insulated with green insulation with any type of civil wk involved complete all as specified. NOTE:Four run of 6 sqmm wire and one run of 6 sqmm wire as earth wire shall be measured as one unit.
M&L in replacement for sheet metal DB for MCBs, SPN, 8 ways, IP-43 double door,single phase, with bus bar, neutral bar/ connectors suitable copper thimbles, lugs etc complete all as specified. Make for Ser No 19 to 24 : ABB/Hager/ Legrand/ Siemens Note:- Make for DB & MCB will be of same make
Supply and fixing in replacement DB's 4 way TPN double door suitable for MCB TPN as incommer and MCB SP 6-32 Amps in outgoing circuits complete, with neutral bar and earth bar complete all as specified.
Supply and fixing in repairs MCB TPN with breaking capacity 10 KA , 415 volts of rating 63Amps suitable for DB complete all as specified.
Supply & Fix in repair MCB SP 6 to 32 Amps, 10 KA, B curve complete.
Supply and fixing in replacement MCB SPN 40 Amps, 240V, complete.
Material and labour for VTPN/ Loadline DB 6 way, 415 volts double door complete with bus bar, neutral link, earth link complete with MCCB 4 way, 125 Amp complete all as specified and directed
Supply and fixing in replacement Deco Ultra Slim linear LED lighting fixture with co-extruded polycarbonate body environmental friendly energy efficient ready to use pack 20W LED 6000K complete all as specified and directed. Make for Ser No 25 to 30 : Philips/ Crompton/ OSRAM/ Havells
Supply & fixing in repair universal batten suitable for fixing of T8 LED tube light 20 watt single side connection all as specified and directed by Engineer in charge.
Supply & fixing in repair 18 LED tubelight inbuilt LED driver retrofit type single side connection with polycarbonate/glass diffuser having high efficacy suited for installation in T8 fitting holders all as specified and directed by Engineer in charge.
Supply & fixing in replacement Decorative mirror light msde of MS duly chromed with polycarbonate diffuser and having LED integrated of 10 watt complete confirming to Model No 582108 of Philips or equivaent in OSRAM/ Wipro / GE complete all as specified & directed by Engineer-in- charge.
S & F energy effcient security light fitting of 25W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street luminaire, with driver, including electric connection with using 3 core flexible copper conductor cable 1.5 sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of GI tubing light grade 25mm dia, 1.2 meter long bent to shape at 120 degree angle at half meter from bottom, including two Nos clamps made out of MS Flat iron size 25x3 mm with suitable nuts and bolts for fixing of brackets including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by Engr-in-Charge:- (a) Lumen system efficancy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 Volts. (c) Temp operating range : Minus 10 0C to Plus 50 0C.
(d) Fower factor minimum 0.95. (e) THD : Max 10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED Driver should be complete with all protections viz open.short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 KV (inbuilt + extended) (l) CCT : 5700 K (m) CRI : Minimum 70 (n) Lens - High effeciency wide angle lens (o) BIS approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fixing in repair decorative wall light fixture made up of Chrome metal and glass, suitable for lamp type 1 x 9 watt retrofit LED lamp including 9 watt LED lamp as fitting complete confirming to model No 30978 of Philips / Bajaj/ GE all as specified.
Supply and fixing in replacement plastic laminated bakelite sheet top cover 3mm thick make hylum of size 9 x 11 inches or equivalent fixed with nickel polished screws with washers including making hole / slots and fixing existing switches on new sheet and making connections as per site requirement including taking out complete all as specified and directed
All as per srl item No. 31 above but 5 x 5 inches
All as per srl item No. 31 above but 8 x 5 inches
Material and labour for replacement of sheet steel made sunken box concealed type od size 8 x 10 inch including opening bakelite sheet, removing old sunken box and fixing new complete with necessary civil work including repair to match existing surface complete including refixing bakelite sheet complete all as specified and directed Make for Ser No 34 to 36 : ABB/ Schneider/ Legrand/ Siemens
All as per srl item No. 34.00 above but 4 x 7 inches
All as per srl item No. 34.00 above but 4 x 4 inches
Supply and fixing in replacement MCCB FP 63 Amp, 415V with fixed thermal magnetic release upto 16 KA breaking capacity including taking out complete all as specified and directed. Make for Ser No 37 to 46 : ABB/ Hager/ Legrand/ Siemens
Supply and fixing in replacement MCCB FP 125 Amp, 415V with fixed thermal magnetic release upto 16 KA breaking capacity including taking out complete all as specified and directed
Supply and fix in repair Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one SP MCB 20 Amps all as specified & directed by Engineer-in- charge .
Supply and fixing in replacement white modular switch 1 way 6 Amp, 230 volt 1 module including taking down existing switch complete all as specified and directed.
Supply and fixing in replacement white modular switch 1 way 16 Amp, 230 volt 1 module including taking down existing switch complete all as specified and directed.
Supply and fixing in repairs Modular fan step regulator 5 speed, 2 module, electronic type, single phase including connection complete after dismantling/ removing unserviceable regulator all as specified.
Supply and fixing in replacement modular socket, 6A, 2/3 pin combined 2 module including taking down complete all as specified and directed.
Supply and fixing in replacement modular socket, 6A/16A, 2/3 pin combined 2 module including taking down complete all as specified and directed.
Supply & fixing in replacement Mini modular MCB SP 32 Amps C- curve all as specified and directed.
S&F blanking strips (dummy) 1/2 module for moduler switch board complete all as specified.
Supply and Fix in repair PVC casing capping (ISI marked) all as specified and direccted by Engineer in charge. Make:- Kalinga/Bajaj/Finolex
Attending complaints of not working/ abnormal noise of fans/ exhaust fan due to loose connection of any wire i.e. neutral/ phase not working of circuits or un-serviceability of any item such as capacitor, rubber real, wire etc rectification of fault including any sort of petty repair required to make the fans functional during 0900 Hrs to 1700 Hrs by deploying electrician with helpers including necessary tools complete all as specified.
Supply and fixing in repairs condenser 2.50 MFD including taking down existing complete all as specified.
Supply and fixing in repairs condenser 3.15 MFD including taking down existing complete all as specified.
Supply and fixing in repairs rubber reel for ceiling fan including nut & bolt including taking down existing rubber real complete all as specified.
Supply and fixing in repairs flexible wire twisted twin core of size 0.75 Sqmm copper conductor cable connected from fan block to 0.60 M long (Provn for ceiling fan & exhaust fan celing rose) complete all as specified and as directed
M&L for PCB assembly kit for BLDC ceiling fan complete incl taking down old UNSV PCB suitable for existing model of ceiling fan 1200mm sweep complete.
Supply and fixing in repair exhaust fan, steel body AC single Phase 230V of size 300mm sweep with, blades, and frame and louvers (louvers made of CRCA frame and aluminium flappers) complete including cutting of hole in wall and making good to disturbed surface all as specified and directed
Material and labour for inner tank suitable for storage type water heater tank 50 Ltrs complete including opening, dismantling water heater and replacement of inner water tank, fixing of insulation and assembling complete all as specified and directed
Material and labour for outer tank with glass wool/ mineral wool insulation suitable for storage type water heater tank 50 Ltrs complete including opening, dismantling water heater and replacement of outer water tank, fixing of insulation and assembling complete all as specified and directed
Supply and fixing in repairs thermostat adjustable type suitable for geyser 25/35/50 Ltr capacity complete all as specified and directed Make:-Expo/Airex/Usha/DANFOSS/Honey Well/SIEMENS /Johnson/ Rapidcool OR equivalent as approved by GE.
Supply and fixing in replacement geyser assembly brass C P type 9/6/8 hole with gasket as per existing type and size complete all as specified & directed.
Supply and fixing in replacement multifunction safety valve for geyser any capacity complete all as specified and directed
Supply and fixing in repairs geyser heating element triangle/ cup type 2.0 KW with gasket complete all as specified and directed. Make:- THEETA/DASSPASS/USHA
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.0mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level with the top edge of electrode not less than 1.5 metres below normal ground level connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and including GI lead protection pipe of GI light grade 15mm dia upto 7.5 mtrs and watering pipe 20mm bore of GI medium grade with funnel and wire mesh, earth plate covered on all sides with min 150mm thick alternate layers of charcoal, salt all as shown in electrical plate No 3 of SSR Part-I 2009 connected to earthing point with PCC chamber and RCC cover in 1:2:4 complete with any type of earth work involved all as specified and directed and testing on completion. Note:- PCC Chamber shall be constructed at least 0.50 mtr away from on the earth pit electrode and pipe for watering shall be provided in slanting manner.
M&L for point wiring for light point with 1.5 Sqmm (nominal area) FRLS PVC insulated unsheathed multi stranded copper conductor of size 1.5 Sqmm cable drawn in and including concealed rigid PVC conduit medium grade (ISI marked) not less than 20mm dia with accessories including cutting chases for laying of conduit /fixing of boxes in walls/floor etc including making good to disturbed surfaces as per adjoining specification and terminated in and incl sunken pressed steel boxes suitable for modular accessories including cover plate of suitable modules complete fixed with nickel polished screws etc including FRLS PVC insulated unsheathed multi stranded copper conductor 1.5 Sqmm single core as arth continuity conductor (green colour) connected with earth dolly with thimble including replacement of existing point wiring any type complete all as specified and as directed by Engr-in-Charge.
All as per srl item No. 62 here in before but for one fan point controlled by one switch complete all as specified
All as per srl item No. 62 here in before but for one bell point controlled by one bell push complete all as specified.
All as per srl item No. 62 here in before but for one light point controlled by two way switches complete all as specified.
All as per srl item No. 62 here in before but for one socket outlet 5 Amps on independent board complete all as specified.
All as per srl item No. 62 here in before but for one socket outlet 5 Amps on the same board controlled complete all as specified.
All as per srl item No. 62 here in before but with 2.5 Sqmm (nominal area) FRLS copper cable for one 3 Pin 15 Amp socket on independent board including one 2.5 Sqmm copper conductor multi stranded green colour PVC insulated unsheathed FRLS cable 1100 volts grade as earth wire connected to common earth and earth dolly with all accessories complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs modular bell push switch 6 Amps, SP, 240 volts including taking down existing bell push complete all as specified
Supply and fixing in repairs modular switch 6 Amps, 240 Volt AC single pole, two way including taking down existing switch complete all as specified.
S&F LED bedside light 3 watt made up of premium material (aluminium) & finish, gooseneck arm, easy to adjust complete confirming to model No 48042 (White colour) of Philips or equivalent in Wipro/Bajaj complete all as specified.
S&F LED Wall Washer light 3 watt min made/ crafted from Aluminium Die Cast its integrated LED with IP 65 protection complete confirming to GAMMA, model No 582088 of Philips / Wipro/ GE/ OSRAM
Material and labour for inner tank suitable for storage type water heater tank 25 Ltrs complete including opening, dismantling water heater and replacement of inner water tank, fixing of insulation and assembling complete all as specified and directed
Material and labour for outer tank with glass wool/ mineral wool insulation suitable for storage type water heater tank 25 Ltrs complete including opening, dismantling water heater and replacement of outer water tank, fixing of insulation and assembling complete all as specified and directed
Supply and fixing in replacement Deco Ultra Slim linear LED lighting fixture with aluminium extruded body body environmental friendly energy efficient ready to use pack 18W LED 6000K complete all as specified and directed. Make Philips/ GE/ CROMPTON/ WIPRO/ OSRAM
AGGARWAL ENGINEERING CO (BID ID -3275547)
CHOUDHARY AND SONS (BID ID -3275390)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .