| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.3 LAccepted-AOC | L1 | Accepted-AOC Lowest rate quoted | |
| 2 | L2₹46.4 L+₹10,502.65 (0.23%)Rejected-Finance | L2 | Rejected-Finance Higher rate quoted | |
| 3 | L3₹47.0 L+₹67,729.86 (1.46%)Rejected-Finance | L3 | Rejected-Finance Higher rate quoted | |
| 4 | L4₹47.1 L+₹86,386.25 (1.87%)Rejected-Finance PO BUD BUD DIST BURDWAN WEST BENGAL PIN 713 403 | BUD BUD | BURDWAN | WEST BENGAL | 713403 | L4 | Rejected-Finance Higher rate quoted | |
| 5 | L5₹47.3 L+₹1.0 L (2.18%)Rejected-Finance 84 B LOWER BURDWAN COMPOUND RANCHI 834001 JHARKHAND | RANCHI | JHARKHAND | 834001 | L5 | Rejected-Finance Higher rate quoted |
Tender Value
₹47.3 L
EMD Value
₹94,600
Closing Date
2 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PANAGARH
GARRISON ENGINEER PANAGARH, MILITARY ENGINEER SERVICES, PO-PANAGARH, DIST-BURDWAN, WEST BENGAL, PIN-713420
All as per BOQ
2021_MES_457644_1
8400-632/E8
Open Tender
Civil Works
Works
180 days
PANAGARH
Class D, Cat a (i), b (i)
6 documents required · 6 mandatory
₹500
GE PANAGARH
₹94,600
Yes
18 Nov 2021
6 Jul 2021
4 Aug 2021
6 Jul 2021
2 Aug 2021
19 Jul 2021
60 days
Amount
Excavation in post holes (or similar holes) each not exc. 0.5 Cum and getting out in hard/dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exc. 25 cm, watering, complete all as specified and as directed.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil ,complete all as specified and directed.
Excavation over area ,not exc 1.5 mtr deep and getting out in soft/loose soil complete all as specified and directed.
Removing excavated soils to a distance not exceeding 50 Metres and depositing where directed at a level n. exc. 1.5 M above the starting point complete all as specified and directed.
Returning, filling in incl spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft /loose soil complete all as specified and directed.
M&L moorum filling/red bajri filling in floor or paving laid in laying n exc 15 cm thick spread levelled and rammed including watering complete all as specified and directed.
Materials and Labour for plain cement concrete (1:2:4) type B-2 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed.
Materials and Labour for plain cement concrete (1:3:6) type C-2 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed.
Materials and Labour for plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed.
M & L for sand filling under floors or in foundation including watering and consolidation complete all as specified and directed.
M&L for fly ash brick straight or curved on plan exc 6 mtr mean redious built in cement mortar (1:4) etc complete all as specified and directed.
Materials and Labour for rendering 15 mm thick, cement plaster, in cement mortar (1:4) on fair face of brickwork or concrete surface of walls, finishing surface even and smooth with using extra cement, complete all as specified and directed.
S & F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St-240 complete all as specified and directed.
S & F framed work conforming toFe 410-W (Gde-E-250) quality A as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete , complete all as specified and directed.
Material and Labour for pre-painted, galvalume aluminium zinc coating GI based corrugated steel sheet, 0.50 mm thick of any colour, having tensile strength of 550 Mpa, as in roof covering/cladding to wall, fixed with self-tapping screws, complete all as specified and directed.
S&F Pre - Painted galvanized aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for PCC 1:2:4 type B 1 using (20 mm graded aggregate) as in , coping apex stones, bed plates and the like including weathering slightly rounded or chamfered angles and throating complete all as specified and directed. Note: Form work required for these items included in the unit rate of this item.
M&L for providing precast RCC,(1:2:4) type B-0 (using 12.50mm graded stone aggregate ) set in cement mortar (1:6) as in cover slabs (for manholes etc ) with plain fair faces, complete all as specified and directed.
Supply and fix mild steel TMT bars 6 to 8mm dia. and over, cut to length, bend to shape required including cranking, bending spirally for hopping for columns,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips complete all as specified and directed
Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on Eaves gutter and pipes any description, n. exc 60 cm girth including holderbats, distance pieces, etc. (length measured over bends, branches etc.) including preparation of surfaces complete all as specified and directed. NOTE:-Rates for painting eaves or valley gutters and hopper heads include for cleaning out same and strengthening joints of gutters with red lead putty before painting.
S&F Low density polythene pipes of dia 50mm bore (LDPE) of pressure rating 6 Kgf/cm2 fixed complete to walls, ceiling or in floor etc.complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitered/stopped ends etc. complete all as specified and directed.
All as per item no. 22 here in above ,add or deduct for each 25 mm girth or part thereof over or under 30 cm complete all as specified and directed.
Supply Laying and Testing and labour for reinforced concrete pipes 150mm, class NP2 laid and joinded complete with collar ,complete all as specified and directed.
Materials and Labour for plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in bed to drain pipes including forming cradles for 150 mm bore pipes , complete all as specified and directed.
M & L for machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size confirming to IS 15658-2006 of 60 mm thick M-35 grade with grey cement and pigment complete all as specified and directed.Note: Design, shade and pattern of fixing of paver block shall be as directed and approved by GE.
Material and labour point wiring for light point/ fan point one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FRLS cables in and including suitable size PVC casing and caping (ISI marked) , including terminal switch boxes of suitable size , sheet top cover (ISI Marked) and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLS PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed.
Material and labour point wiring for one socket outlet on independent board controlled by one, one way switch using 4.0 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated Unsheathed FRLS cables in and including suitable size PVC casing and caping (ISI marked) , including terminal switch boxes of suitable size, sheet top cover (ISI Marked) and 4.0 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FRLS cable as earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed.
Supply and fix switch socket combination 2 in 1 , 5 pin , (6 Amps ) flush type controlled by one switch complete all as specified.
Supply and fix switch socket combination 2 in 1 , 6 pin , (16 Amps ) flush type controlled by one switch complete all as specified.
Supply and fix ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified.
Supply and fix switch piano flush type, single pole , 6 Amps, one way complete all as specified.
Supplying and fix two single core ,4 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade drawing in and including nd including suitable size PVC casing and caping (ISI marked) including 4 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade earth wire , complete all as specified and directed.
Supplying and fix two single core ,6 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade drawing in and including nd including suitable size PVC casing and caping (ISI marked) including 6 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade earth wire , complete all as specified and directed.
Supply and fix Vertical distribution board(VTPN) double door TPN 4 way with IP 54 multiphase outgoing suitable for mounting 100 Amps as incomer with Bus bars, Neutral links complete with all accessories complete all as specified and directed.
Supply and fix epoxy powder coated sheet metal enclosure for DBs, double door , Single pole and neutral 240 V, 4 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete with all accessories complete all as specified and directed.
Supply and fix epoxy powder coated sheet metal enclosure for DBs, double door , Single pole and neutral 240 V, 4 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete with all accessories complete all as specified and directed.
Supply and fix epoxy powder coated sheet metal enclosure for DBs, double door , Tripal pole and neutral 240 V, 4 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete with all accessories complete all as specified and directed.
Supply and fix MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Voltsand to be housed in DBs including necessry connection complete all as specified and directed. Note :-Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating
Supply and fix MCB SPN 6-32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed. Note :-Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating
Supply and fix MCB TPN 63 Amps, 'C' series 10kA, 415 Volts and to be housed in DBs complete including necessry connection all as specified and directed. Note :-Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating
Supply and fix MCCB of 4 pole , 415volts of capacity 100 Amps with breaking capacity of 16 KA Fixed thermal and fixed magnetic setting including necessry connection complete all as specified and directed.
Supply and fix Heavy Duty Metallic Padestal fan Turbo charge of 600mm sweep size with base plate,complete all as specified and directed.
Supply and fix Heavy Duty Metallic Exhaust fan Turbo charge of 600mm sweep size,700 RPM including cutting /opening holes in steel structure / brick masonary wall and making good the disturbed surface as original,complete all as specified and directed.
Supply and fix Heavy Duty Metallic Exhaust fan Turbo charge of 450mm sweep size,1400 RPM including cutting /opening holes in steel structure / brick masonary wall and making good the disturbed surface as original,complete all as specified and directed.
Supply and fix Heavy Duty Metallic Exhaust fan Turbo charge of 400mm sweep size, including cutting /opening holes in steel structure / brick masonary wall and making good the disturbed surface as original,complete all as specified and directed.
Supply and fix Heavy Duty Metallic Exhaust fan of 300mm sweep size, including cutting /opening holes in steel structure / brick masonary wall and making good the disturbed surface as original,complete all as specified and directed.
Supply and fix Exhaust fan of 225mm sweep size, including cutting /opening holes in steel structure / brick masonary wall and making good the disturbed surface as original,complete all as specified and directed.
Supply and fix Heavy Duty Metallic high speed wall mounted 600mm sweep size,1400 RPM,turbo speed including nut bolts and clamp with all fixing aggangement ,complete all as specified and directed.
Supply & fixing ceiling fan of capacity 1200mm sweep size ,240 volts , ISI mark,BEE star 5 rated, complete all as specified and directed
Supply & fixing wall fan of capacity 300 mm sweep size ,240 volts , complete all as specified and directed
Supply & fixing window AC of capacity 1.5 Ton,240 volts , ISI mark,BEE star 5 rated, complete all as specified and directed
Supply & fixing Inverter type split Ac of of capacity 1.5 Ton,240 volts , BEE star 5 rated, complete all as specified and directed
Supply & fixing refrigerator of capacity 310 ltr, BEE star 5 rated, complete all as specified and directed
Supply, laying / fixing / connecting, testing and commissioning of LT under ground cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor,1100 Volts cross sectional area 95Sqmm x 3.5 core in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) , complete all as specified and as directed Note : (i) Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant item. (ii) Cable Route Indicator made of metal of height 300mm above GL duly written ''LT CABLE'' to be fixed on every 30 mtr distance with pcc (1:3:6), 150 mm below the GL ,cost of indicator and pcc to be considered in this item rate
All as per item No 55.00 mentioned here-in-above but 35 Sqmm 3½ Core complete all as specified and directed.
Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and directed. (Note : Punned thickness shall be measured). Note :- Punned thickness 18 cm shall only be considered for payment.
Supply and lay in trenches fly ash bricks, for cable protection all as specified and directed.
Supply and fixing/laying 50mm bore, steel tubings, galvanised, light grade with all fitting laid across road , in trenches or across PCC drain or along electric pole or floor/wall etc for protection of cable, complete all as specified and as directed.
Material and labour for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32 x 6 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate 3 of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Supply ,install ,testing and commissioning cubical housing cabinet type ,weather proof,outdoor type CPRI approved,factory made LT panel board,totally enclosed ,dust and vermin proof openable front and back side ,canopy headed,connected with suitable size MS angle iron frame,overall dimension suitable to operate submersible pump ,fabricated with CRCA sheet 3.15 mm thk including IP-55 protection ,installed on concrete base made of PCC (1:3:6) type C1 using 20mm graded stone aggregate ,including self locking arrangement.,complete all as specified and directed. New panel board shall coprise of :- (i) Copper busbar rating :600 Amps-04 Nos (ii)indication lampfor RYB :01 Set (iii) MCCB-400 Amp,4 pole, 35KA Adj thermal & fixed magnetic setting,415 V ,50Hz AC-01 No (Incoming). (iv) MCCB-125 Amp,4 pole, 25KA Adj thermal & fixed magnetic setting,415 V ,50Hz AC-05 No (Outgoing). (v) MCB-40 Amp,4 pole, 16KA f 415 V ,50Hz AC-02 No (vi) S&F digital ampere meter 3 1/2 display incl CT having CTR 400/5-01Nos. (vii) S&F digital Voltmeter 0-500 V-01 No. (NOTE:-Rates of pcc to be considered in this quoted item rate.)
M/S TRIVENI BUILDERS
SARASWATI ENTERPRISE (INDEX NO CEEC D-81)
ROY ENTERPRISE
UNITED BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .