Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.3 LAccepted-AOC SHOP NO 13 45 FEET ROAD BHARAT COLONY FARIDABAD HARYANA 121014 | FARIDABAD | HARYANA | 121014 | L1 | Accepted-AOC L1 bidder lowest | |
| 2 | L2₹38.4 L+₹40,136 (1.06%)Rejected-Finance 1476 SARASWATI COLONY CHERITAL JABALPUR | JABALPUR | MADHYA PRADESH | 482001 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹42.0 L+₹4.0 L (10.5%)Rejected-Finance 1257 SCHEME NO 5 NEAR HB COLLEGE VIJAY NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹44.0 L+₹6.1 L (16.0%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹44.9 L+₹6.9 L (18.2%)Rejected-Finance B 87 SHAM NAGAR KHAYALA ROAD NEW DELHI 110018 | NEW DELHI | NEW DELHI | DELHI | 110018 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
26 Sept 2024, 6:00 pmClosed
GE (West) Jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No. 54 Jabalpur Cantt-482001 (MP)
REPAIR AND MAINT OF OLD UNSV PERIMETER AND EXTERNAL LIGHT FITTINGS WITH LED LIGHTS AND MAINT OF JUNCTION BOXES, CABLING AND ALLIED WORK IN THE AREA-I UNDER GE (W) JABALPUR
2024_MES_672131_1
8765/E8
Open Tender
Civil Works
Item Rate
180 days
GE (West) Jabalpur
As per tender documents
6 documents required · 6 mandatory
₹500
GE (West) Jabalpur
₹98,000
23 Oct 2024
5 Sept 2024
28 Sept 2024
5 Sept 2024
26 Sept 2024
12 Sept 2024
5 Sept 2024 - 7 Sept 2024
Amount
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete all as specified and as directed.
M/L for Removing excavated material to a distance n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed.
M/L for Returning , filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
Supply, fixing and connecting in repair PVC insulated, round,sheathed, multicore, industrial flexible cable with bright annealed copper conductor, 1100 volts grade cable of size1.5sqmm, 3 core, confirming to IS 694-1990 complete all as specified and directed
Taking down old UNSV light fitting of any size and type for repair and refixing of the same after necessary repair including removing of carbon, replacement & reconnection of wire, driver, module etc complete all as specified and directed. Note : 1. Material required for repair of light fitting shall measured and paid seperately under respective items.
Trimming of tree branches Clearing of LT/HT line 4 mtr all around by cutting tree branches at ground level of any numbers and any girth on any numbers of conductors/earth wire complete all as specified and directed by Engr in charge. Note FOR Item No. 5&6: 1. Contractoror shall provide 2x helper & 01xElectrician daily incl sunday & holiday along with vehicle, ladder, petrol operated branch/tree cutting machine, saftey belt, multimetre, rain coat etc to perform daily routine work. No additional payment shall be paid to the contractor in this regard. Above quoted rate shall be inclusive of this. 2. In case of non-providing above facilities, recovery of Rs 1000.00 per day will be recovered from the RAR. 3. Max one time payment shall be given to the contrator at same location in three month if work carried out 1 or more times at same location in three month for item No 5 &6.
S&F the SPD for LED light singe phase (1P+N) 10 KA complete all as specified & directed.
Supply Only driver suitable for 45-70 Watt existing LED Street light fitting as required at site complete all as specified and as directed.
Supply Only driver suitable for 90-200 Watt existing LED Street light fitting as required at site complete all as specified and as directed.
Taking down old unserviceable street light fittings HPSV of any capacity from pole / Wall / other similar situation and kept aside for schedule of credit complete all as specified and directed.
Supply and fixing energy saving and environmental friendly long life LED street light luminaires, min 5400 system Lumen out put, max 45 watt made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having bottom opening seperate driver compartment with IP66 protection and impact resistance of IK08 complete all as specified and as directed.
Supply and fixing energy saving and environmental friendly long life LED street light luminaires, min 7700 system Lumen out put max 60 watt made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having bottom opening seperate driver compartment with IP66 protection and impact resistance of IK08 complete all as specified and as directed.
Supply and fixing energy saving and environmental friendly long life LED street light luminaires, min 8400 system Lumen out put , max 72 watt, made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Top opening seperate driver compartment with IP66 protection and impact resistance of IK07 complete all as specified and as directed.
Supply and fixing energy saving and environmental friendly long life LED street light luminaires, min 10300 system Lumen out put, max90 watt, with inbuilt 2 hr battery backup inverter type made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Top opening seperate driver compartment with IP66 protection and impact resistance of IK07 complete all as specified and as directed.
Supply, fixing and connecting in repair LED street light fitting 100-120, min lumen output of system 12000 lumen having LED as light source, pressure die cast alluminium housing and lens embedded PC cover having IP-66 protection, IK07 with 10kV surge Built in Surge protection device, heat sink, operating voltage range 140-270 voltage, CRI >70%, THD<10%, complete all as specified and directed.
Supply and fixing energy saving and environmental friendly long life LED Flood light luminaires, 400 watt WITH MIN 40000 system Lumen out put, warm white, exclusive innovative die cast aluminium IP66 LED Flood light suitable for highlighting architectural facade and general purpose lighting complete all as specified and as directed
Supply and fixing energy saving and environmental friendly long life LED Flood light luminaires, min 14400 system lumen output and max 120 watt, exclusive innovative die cast aluminium IP66 LED Flood light suitable for highlighting architectural facade and general purpose lighting complete all as specified and as directed.
Supply, fixing, connecting and testing of Automatic Street light switch using infrared Sensor based Nature Switch for automatic switching of street lights, Nature switch operation should be based on Natural light lux level. Required illumination level for switching on is < 30 lux and for switching off > 10 lux. The sensor should also have part night operation facility for 4 - 12 hours. The sensor alongwith suitable power contactor, incoming-outgoing MCBs should be enclosed in a pole/wall moutaed enclosure made out of Rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP-54, The circuit should be suitable enough to take 8 kw single phase load with contactor 63 Amps conforming to IEC-60947-4-1/IS-13947-4-1 & incoming and outgoing MCBs of rating 63 Amps conforming to IEC-60898/IS-8828 and circuit wiring of minimum 16sqmm coper conductor wire in and including providing of 50x6mm flat iron clamp, necessary nuts and bolts complete incl taking down of existing arrangement complete all as specified and as directed.
Dismantling/ taking down of existing street light switching system and Supply, fixing, connecting and testing of Automatic Street light switch using infrared Sensor based Nature Switch for automatic switching of street lights, Nature switch operation should be based on Natural light lux level. Required illumination level for switching on is < 30 lux and for switching off > 10 lux. The sensor should also have part night operation facility for 4 - 12 hours. The sensor alongwith suitable power contactor, incoming-outgoing MCBs should be enclosed in a pole/wall moutaed enclosure made out of Rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP-54, The circuit should be suitable enough to take 8 kw Three phase load with contactor 25 Amps conforming to IEC-60947-4-1/IS-13947-4-1 & incoming and outgoing MCBs of rating 32 Amps conforming to IEC-60898/IS-8828 and circuit wiring of minimum 10sqmm copper conductor wire in and including providing of 50x6mm flat iron clamp, necessary nuts and bolts complete all as specified and as directed.
Supply, laying or fixing or passing through pipe commissioning and testing of PVC XLPE insulated, armoured heavy duty, electric cable with aluminium conductor, 1100 volts grade, multi -stranded of SIZE 10SQMM 2 CORE including suitable size lugs including taking out /dismantling of existing cable. Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately under relevant items:-
Supply, laying or fixing or passing through pipe commissioning and testing of PVC XLPE insulated, armoured heavy duty, electric cable with aluminium conductor, 1100 volts grade, multi -stranded of SIZE 16SQMM 4 CORE including suitable size lugs including taking out /dismantling of existing cable complete all as specified and as directed.. Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately under relevant items:-
Supply, laying or fixing or passing through pipe commissioning and testing of PVC XLPE insulated, armoured heavy duty, electric cable with aluminium conductor, 1100 volts grade, multi -stranded of SIZE 10 SQMM 4 CORE including suitable size lugs including taking out /dismantling of existing cable complete all as specified and as directed.. Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately under relevant items.
Material and labour for painting to steel tubular pole/Rail Pole of HT/ LT over head line and all MS clamps, cross arm work on poles with one coat of superior aluminium paint including necessary preparation of surfaces and painting of alternate strip with black and white synthetic enamelled paint strip 05 Nos each of 30 cm height up to 1.5mtr above PCC benching/coping complete all as specified and as directed.
Supply and fix junction box made out of polycarbonate with IP 55/IP 65 protection of size 200 x 160 x 98 mm, 5 way having terminals for termination of cable with necessary nuts and bolts including -02 Nos polycarbonate cable gland and 01 Nos DIN rail for mounting of MCB and 01 No, MCB SP, 10 KA, 6 Amps and including fixing clamp of FI 50 x 6mm with necessary nuts and bolts complete in and including taking down of existing u/s junction box of any type complete all as specified and as directed.
Supply, laying & fixing double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i.e. all type of joints, Sockets, Elbows, bends and End caps of size 50 mm outer dia and 38 mm inner dia etc complete all as specified and directed.
Taking down old unserviceable solar light light fitting of 20-45 W along with battery, panel box etc and refixing after necessary repair including replacement of battery as per exising size/type/specifications, wire, cleaning & removing of dust, repair/replacement of battery lux & cable etc complete all as specified and directed.
Taking out existing PCC/steel tubular LT electric poles and LT/HT old unused pole of any length including breaking of cement concrete, necessary excavation and earth work, dismantling cross arms, M.S. clamps, insulators etc and carefully taking down existing over head conductors complete all as specified and directed.
Supply and erecting steel tubular poles complete with cast iron base plate, finial taper plug , bolts Nuts & screws complete all as specified type 410SP 31 of 9 mtr long including painting of pole with one coat red oxide primer & two coats of aluminum paint & emedded portion shall be painted with two coat of black bituminous paint all as specified and directed. Note :- 1. Writing pole No with yellow shade on black base using synthetic enamel paint having height of words exc 5 cm as directed. 2. Excavation & earth work & PCC where required shall be measured & paid separately under relevant items.
M&L for providing cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for providing cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation filling complete all as specified and directed.
M&L for providing cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) for coping of poles including necessary form work and finished the surface complete all as specified and directed.
Excavation in trenches, n exc 1.5m wide and exc 1.5m n exc 3m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. n exc 10sqm on plan and getting out in any type of soil etc complete all as specified and directed
RAINA SALES AND SERVICES (BID ID -3100709)
Sachdeva Enterprises (BID ID -3100917)
mandeka constructions (BID ID -3100192)
New Era Engineers (BID ID -3100929)
RAVINDRA ELECTRICAL (BID ID -3100528)
ELCON (BID ID -3102491)
SHRI KRISHNA CONSTRUCTIONS (BID ID -3100286)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .