Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-AOC | L1 | Accepted-AOC REASONABLE | |
| 2 | L2₹9.1 L+₹6,641 (0.74%)Rejected-Finance | L2 | Rejected-Finance HIGH RATE | |
| 3 | L3₹9.1 L+₹10,042.65 (1.12%)Rejected-Finance | L3 | Rejected-Finance HIGH RATE | |
| 4 | L4₹9.1 L+₹11,690.75 (1.30%)Rejected-Finance HATIA ROAD DANGALPARA DISTT DUMKA JHARKHAND PIN 814101 | DUMKA | DUMKA | JHARKHAND | 814101 | L4 | Rejected-Finance HIGH RATE | |
| 5 | L5₹9.2 L+₹17,393.90 (1.93%)Rejected-Finance | L5 | Rejected-Finance HIGH RATE |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
22 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI TAPAN DAS
AGE I AF STN SINGARSI
REPAIR/ MAINT OF VOLTAGE STABILIZERS VCB AT 774SU RADAR SUB STN AND THD POWER HOUSE AND OTHER CONNECTED WORKS AT AF STN SINGARSI UNDER AGE I AF STN SINGARSI
2023_MES_607385_1
C/8623/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE I AF STN SINGARSI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
AGE I AF STN SINGARSI
₹18,000
Yes
6 Sept 2023
30 Jun 2023
29 Jul 2023
30 Jun 2023
22 Jul 2023
15 Jul 2023
Amount
M&L for Filteration of Voltage Stablizer Power oil os any capacity by continous circulation of transformer oil through mechanical filters to achive the desired dielectric strength of 35 KV for one minute at 4 mm gap, complete all as specified and as directed by eng-in-charge. Note: 1.Oil samples are to collected from top and bottom of oil tank and test results to be submitted for each sample before and after filteration.
Supply and topping up /replacement of new transformer/voltage stablizer oil of dielectric strength 35 KV at 4 mm gap in transformers of various cap installed in various locations.complete all as specified and as directed by eng-in-charge. Make of Transformer/Voltage stablizer oil: Power Oil / Indian Oil / Rinkyl /Apar Note : New oil in the Voltage Stablizer will be filled in the Voltage Stablizer only after filteration and dehydration of existing oil of theVoltage Stablizer. (b) New oil shall be supplied in sealed barrel with test result and test certificate.
Supplying, laying, testing and Commissioning cable XLPE insulated aluminium conductor,stranded, armoured, PVC sheathed, LT 1100 volt grade, heavy duty as per IS-7098 and providing suitable lugs and cable glands, laid in trenches/ ducts/fixed to wall/ roof/ poles including taking down existing cables of 120 sqmm, 3.5 core, complete all as specified and directed.
Ditto as per item No 03 but 50 sqmm, 3.5 core, complete all as specified and directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation of poles, stays, laying of UG cable/ pipes & getting out in soft/loose soil, complete all as specified and as directed.
M & L for providing dry river sand as in sand cusioning for underground cable protection including punning down sand in layers, complete all as specified and as directed. Note: Only punned thickness of sand shall be considered for measurement purposes
Supplying and laying common burnt clay sub class ‘B’ bricks of size 230 mm x 113 mm x 75 mm, laid perpendicular to axis of cable for protection of LT cables, complete all as specified and as directed.
Removing of excavated material (soil) to a distance n.exc 50 meter and depositing where directed at a level n.exc 1.5 meter above the starting point.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil, complete all as specified and as directed.
M&L road cutting of size (30x45) cm width and depth 30 cm width 45 cm depth for laying of cables incl making good the road with necessary returning fillingand bituminious portion with concret and bituminious mixture and cemented portion with PCC in 1:2:4 , 15 cm thick from top and matching the surfaces with existing,complete all as specified and as directed.
Supplying and laying GI pipe Light grade (ISI marked) 50mm bore with connecting accessories, laid under road/ drain/fixed on wall etc for protection of cables,complete all as specified and as directed
M&L Danger notice plate of 1.6mm thick mild steel sheet, of size 250mm x 200mm for 11 KV, vitreous enamelled white, with letter, figures and convetional skull and bones in signal red colour and fixed in front side with suitable screws / nuts, bolts & washers, complete all as specified and as directed.
All as per item No 12 here in before but of size 200mm x 150mm for LTcomplete all as specified and as directed.
M&Labour for staright through jointing kit for 120 sqmm to 240 sqmm, 3.5 core, heat shrinkable, complete all as specified and as directed.
M&L for load balancing 3phase Voltage stablizer input voltage 300 to 480V, output voltage 415 +/-1% by setting up gear speed throught RC netrwork, setting up relays and control circuits load cleaning the contacts, lubrication of moving parts including servo moter all as specified and refixing the same with checking of control wiring , testing & Calibration of Auto/Mannual system for satisfactory functioning,complete all as directed by Eng-in-Charge.
Supply and fix Isolator TPN 63 A 415 Volts 10 KA breaking Capacity B Series characterstics mounted on DIN Rail and connecting up all, complete as specified and as directed. Make:-Legrand / Seimens / Hager /Havells
Taking down old unserviceable MCCB and Supply and fix MCCB 125 A, 4 pole, 415 Volts 36 KA breaking Capacity ,AAN frame fixed onExisting pannel in power house/feeder pannel and connecting up all as specified and as directed& in the process of fixing of MCCB minor drilling, clamping ,screw ,nut bolt included in quoted rate all complete as specified and as directed. Make-: L&T/Havells/Hager/Legrand
Ditto as per item No 17 above but 100Amp, all complete as specified and as directed.
Ditto as per item No 17 above but 200Amp, all complete as specified and as directed.
Taking down old unserviceable MCCB and Supply and fix MCCB 630 A with enclosure , 4Pole ,Ui 690V Uimp 6KV Cat A 50/60Hz 50Degree C,Ue AC 600V Icu25KA & Ue AC 380V Icu 65kA, fixed on power house/sub satns and connecting up all as specified and as directed& in the process of fixing of MCCB minor drilling, clamping ,screw ,nut,bolt &washer all as directed by Eng-in-Charge included in quoted rate all, complete as specified and as directed. Make L&T/ Havells / Hager/Legrand
Dismantling of 250 KVA capacity voltage stabiloizer by unscrewing of nut bolts of main cover carefully, removal of incoming and outgoing cables and replacement of damaged parts as per existing and assembling after completeion of repair, complete all as specified and as directed. (Note:Cost for replacement of damaged nut and bolts should be included in rate quored)
Replacement of servo motor assembly of capacity 10kg/cm as per existing complete all as specified and as directed.
Replacement of control circuit assy as per existing complete all as specified and as directed.
Replacement carbon bushings as per existing complete all as specified and as directed.
Dreplacement of RC Network as per existing complete all as specified and as directed.
Replacement of digital volt meter complete all as specified and as directed.
Replacement of Control switch as per existing complete all as per specified and as directed.
M/S AMARNATH AGARWALLA
DANATION CONSTRUCTIONS
M/S KUMAR AVINASH
M/S Subhadip Enterprise
SHARMA ENTERPRISE
M/S MBS TRADING CO
M/S New Builders Corporation
M/S SINGH ENTERPRISE
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .