Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹8.3 Cr
EMD Value
₹16 L
Closing Date
17 Feb 2026, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Satish Kumar
XEN Office (Chandigarh)
DevelopmentofAdventure Tourism Hub at Tikkar Taal
2026_HBC_494890_1
2026386ECC3B BA8F 4E32 861C 1EB485E3916A1269HTC
Open Tender
Civil Works
Works
365 days
BHOJ PONTA BHOJ PONTA
DevelopmentofAdventure Tourism Hub at Tikkar Taal
2 documents required · 2 mandatory
₹1,180
Yes
₹16 L
Yes
Red Bishop
20 Jan 2026
5 Jan 2026
18 Feb 2026
5 Jan 2026
17 Feb 2026
19 Jan 2026
12 Jan 2026
Providing and fixing of paris false ceiling with GI suspenders using fasteners and frame work with GI members using best quality wire meh (23 gauge with 12 squares per inch) with 12 mm POP Plaster approved quality Sakarni odhar shri make cornice, beading, if any including two coats of plastic emulsion after preparation of surface, priming coat to the full satisfaction of the EIC (i) main member will be of 20 gauge @ 2’-0” (ii) secondary member will be of 24 gauge 3’-0” (iii) cutting of holes for electric fitting as per drawing and design (iv)work will be executed as per drawing and design (v) floor area of false will be measured, no extra area will be paid of offsets and Dome etc.)
P/F Waste coupling 32 mm full thread with 80 mm height (ALD-CHR-705) Complete in all respect (N.S) Jaquar make.
Providing and Fixing of Modular Commercial Kitchen with all its necessary Accessories and Fixtures required in the site, to include providing samples for approvals from engineering incharge. The given rate includes the cost of all materials, labour, necessary tools, ladders, scaffolfing etc. complete in all respect as per technical specifications mentioned in the drawing and quotation-Main kitcghen- SS undercounter Refrigertor with Overheadshelf and heating element Size 72x24x34 plus 18, Deep Freezer of 300L capacity, SS working Table with two undershelf Size 36x30x34 plus 4, SS Single Sink Size 24x30x34 plus 4, SS undercounter with Makeline Size 60x24x34, SS 4 Burner Continentl Range with Ash Tray and one undershelf Size 30x30x34 plus 4, SS Three Burner CHinese Cooking Rnge with One Ash Tray, Undershelf and Tap For Stock pot Size 72x30x34 plus 12,SS Three Burner Indin Cooking Range with sh tray and one undershelf Size 72x30x34 plus 4, SS Utensile Rack with 4 Size 48x24x72, SS Store Rack with 5 Shelf size 60x18x72,SS Work Table with Two Undershelfs Size: 48x30x34 plus 4, SS Table for Conti Section Size: 54x30x34 plus 4, Single Deck Pizz oven, SS Prepration Table with one undershelf Size 72x30x34 plus 4, SS Prepration Table with one undershelf size72x30x34 plus 4, SS Preprtion Table with One Undershelf Size: 60x30x34 plus 4,SS Deep Fryer with Tap Cap 12Ltr, SS plate Rack with three Side Covering Size 54x18x34, SS plate Rck with Three Side covering Size 48x18x34, Providing and fixing of Exhaust Hood with Waffle Filters, GI ducting for fresh Air Exhaust, Pantry - SS Sink size 24x24x34 plus 4, SS table with two undershelves Size 48x24x34 plus 4, SS Table with two undershelf Size: 60x24x34 plus 4, Washing Area SS Dishlanding Table with OHS size 66x24x34 plus 4 plus 18, SS 3 Sink unit Size 72x24x34 plus 4, SS Rack with four Shelf Size:72x24x72, Utensile Table with One Undershelf Size: 48x30x34 plus 4, Tandoor Area: SS Coal Tandoor with Heaavy duty Wheels and Lid Size: 30x30x34 plus 4, SS working Table with with 2 undershelf Size: 48x30x34 plus 4, SS Rack with four Shelf Size60x24x72, Single Sink Size 24x30x34, SS Undercounter Refrigerator with Overheadshelf qand Heating element Size: 72x24x34 plus 18, Providing and fixing of exhaust hood with waffle filter with fresh airchange duct, Storage Are- SS STorge Rack with 4 Shelf Size: 72x24x72, Four Door Vertical Refrigerator Commercial Use Capacity 1100Ltrs, SS STorage Drum with Lid Size dia 24`x34` Gas Pipeline- Providing and Fixing of Gas pipeline with complete accessories and Gas Bank
Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height.
Supplying, installation, Testing and Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffesuser and construction as per IS :10322 with driver as per the requirement with Driver efficiency )85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short and Open circuit protection ,THD ( 10% , P. F.=0.95, IP20, CRI )80 , UGR (Unified Glare Rating) ( 19, Flicker free (flicker should be below 5%), life time (LED,Driver and electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin),SDCM (Standard Deviation Color Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.).Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required. System lumen effiacy =105 and (120 lm/Watt output. LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.(Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C)- Powder coated die cast /Extruded aluminum Body including trim.-15 W
Supplying, installation, Testing and Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency )85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short and Open circuit protection ,THD ( 10% , P. F.=0.95, IP20, CRI )80,Flicker free, (flicker should be below 5 %), life time (LED,Driver and electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required. System lumen efficacy =105 (120 lm/Watt output. LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).- Powder coated die cast / Extruded aluminium Body (Thickness = 1.20 mm)- 40 Watt- IP 40 Rated
Supply, Installation, Testing, and Commissioning of Factory- Fabricated Distribution Board.-The distribution board will be supplied, installed, tested, and commissioned with rust inhibition. It will be made of a powder-coated MS sheet 2 mm thick and have a front side hinged and a locking system with double doors that can be opened. This design shall be suitable for flush mounting with fully insulated copper busbars for each phase, shrouded neutral bars, earth bars, a color-coded interconnecting wire set, cable ties, and a DIN rail for mounting FP MCBs/MCCBs as incomers and DP/RCBO/RCCB/SP MCBs as outgoings. The top and bottom cable/wire end boxes will be provided to keep loose wires and cables organized and complete as required. (Details of incoming and outgoing connections will be based on site requirements and the instructions of the engineer-in-charge.)
Supplying, installation, Testing and Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency )85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short and Open circuit protection ,THD ( 10% , P. F.=0.95, IP20, CRI )80,Flicker free, (flicker should be below 5 %), life time (LED,Driver and electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required. System lumen efficacy =105 (120 lm/Watt output. LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).- Powder coated die cast / Extruded aluminium Body (Thickness = 1.20 mm)- 40 Watt IP 65 Rated
Supplying, Installation, Testing and Commissioning of mirror light integrated IP20 Batten Led fixture 600 mm 10 W with Surface Mounted with aluminium housing and Polycarbonate diffuser,minimum system efficacy of 100lm/W with P.F.)0.95 with THD(20% ,CCT 6500 K,CRI 80,Surge Protection 2 Kv, IP20.The LED with Useful life of 50000 Hrs at L70. The Input voltage range shall be 150V to 270V including making suitable arrangement for fixing. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required. i
Supplying, Installation, Testing and Commissioning of 30 Watt Suspended type decorative type luminaire circular ring type, luminaire shall be complete with LED Light Engine not LED Bulb Solution. having Extruded Aluminium housing with HET diffuser with minimum system lumen efficacy of 100 lumen per watt. P.F.)0.95 with THD(10% ,CCT 5700 K/4000K, CRI 80.The LED with Useful life of 50000 Hrs at L70. The Input voltage range shall be 140V to 300V. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.
Supplying, Installation, Testing and Commissioning of 20 Watt Suspended type decorative type luminaire circular , luminaire shall be complete with LED Light Engine not LED Bulb Solution. having Extruded Aluminium housing with HET diffuser with minimum system lumen efficacy of 100 lumen per watt. P.F.)0.95 with THD(10% ,CCT 5700 K/4000K, CRI 80.The LED with Useful life of 50000 Hrs at L70. The Input voltage range shall be 140V to 300V. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.
Supplying, Installation, Testing and Commissioning of curve light LED 15W/ mtr luminarie, absolute homogeneous illumination over the entire light emitting surface in curve form Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.
Supply, Installation, Testing and Commisioning of Up Down Light, Material: Aluminum plus Acrylic, Power: 2 X 5W , Voltage: 100-240V,CCT: 3000K, IP54 ncluding making suitable arrangement for fixing , connection with 3 x 1.5 sq.mm. PVC insulated FRLS PVC sheathed copper conductor complete as reqd.Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.
Supply installation,testing and commissioning of 7/10 W LED STEP LIGHT having non-corrosive cast aluminium body.Low power White LEDs (WH) covered with heat resistant frosted glass fixed to the housing with frame protection grill.LED Used shall be COB type CCT up to 5700K ,IP54. An operating Voltage Range of 140 to 280V AC,PF)90,50Hz. LED driver should be constant current type.he luminaire should have loop in loop out provision for power complete i/c termination as reqd complete i/c all civil job associated with it.
Supplying, Installation, Testing and Commissioning of 250 mm sweep fresh air ventilating fan with aerodynamically designed and balanced blades suitable for operation on 230 v single phase AC supply complete connection with 3 x 1.5 sq.mm. PVC insulated FRLS PVC sheathed copper conductor etc as required as reqd.with all accessories as required
Supplying, Installation, Testing and Commissioning of 300 mm sweep, 900 rpm heavy duty exhaust fans with suitable louvers / bird screen protection and all accessories complete with Aerodynamically designed and Balanced Blade, Dynamically balanced impellers for smooth and vibration-free operation,Pre-lubricated double ball bearing for maintenance free running suitable for operation on single phase AC supply complete connection with 3 x 1.5 sq.mm. PVC insulated FRLS PVC sheathed copper conductor etc as required as reqd.
Fabricating, Supplying, Installing, Testing and Commissioning of (Non TTA type) outdoor type (Weather Proof and Water Proof) with protection (IP-54) panel, complete including the following:sheet steel cubicle type panels fabricated from 14 guage thick CRCA sheet, dust and vermin proof, outdoor type distribution MV Panels with hinged lockable doors fabricated from 2mm thick CRCA sheet, suitable for 415V, 3 phase 4 wire 50Hz AC supply with rear / bottom access for cable alley and with segregated bus-bar chamber and including supplying and fixing following switchgears, meters and accessories, inter-connections, bonding to earth, bottom base channel of MS section not less than 100mmx50mmx5mm (thick). Fabrication shall be done in transportable section ,entire panel shall have a common earth busbar at rear with 2 nos earth stud cable alleys, cable gland plates powder coated painting of approved shade after antirust treatment (with min seven tanks ) and marking as specified. Switch boards complete as per schematic diagram:(Scope of work also includes installation of the same on suitable size of foundation / on MS angle iron frame work of size 50mm x 50mm x 6mm, 90 cm long legs out of which 45 cm duly grouted in cement concrete 1:2:4 (1 cement : 2 sand :4 stone aggrete 20mm) as per site requirement) The MCCB rating up to 250A shall have thermal megnatic based adjustable over current, short circuit protection and above 250A MCCB shall have microprocessor based adjustable over current, short circuit, earth fault protection. All MCCB`s shall be Ics = 100% Icu, with spreaders, rotary handle and pad locking arrangement. Control wires shall be of 1.1 KV 2.5 sq.mm FRLS copper wires and neatly bunched separately and adequately supported so as to prevent sagging and strain on termination. All concealed hinged doors and covers shall be provided with suitable flexible earthing connections. All panel shall be provided with names plates of black perplex in white Engraving and to be provided on both front and back side of the panels as safety feature and for proper identification of panel. The scope of work also includes of dismantling of existing LT Panels (i/c disconnection of incomer and outgoing feeders,earthing etc ) shifting, leading and storage at designated location for installation of the LT Panels and also making temporary arrangement so that supply to all the load being fed from existing panel is continued and not disturbed as per direction of Engineer -in-charge complete as required.( Material required for temporary connection to be arranged by contractor only, no extra claim shall be entertained for the same.) MAIN DISTRIBUTION cum Non ESSENTIAL PANEL (Lake Area) Incommer 01 No. 400 A 36 KA FP Moulded Case Circuit Breaker with microprocessor based adjustable over current, short circuit, earth fault protection with ON /OFF/TRIP indications. (From Transformer) Meterin and Indications 1 No. Digital Multifunction meters with basic parameters like frequency, KW, KVA, KVAR, etc. complete with CTs and Protection MCB. RYB Phase Indication Lamps and ON/OFF LED Indicating Lamps with 2 Amp. SP MCB for protection. INCOMING FROM SOLAR PLANT 200 KW 1 No. 400A feeder incomer and Each incomer breaker feeder shall have following: 1 No. 400A 36KA FP Moulded Case Circuit Breaker with microprocessor based adjustable over current, short circuit, earth fault protections, 3 No. indicating lamps to show the incoming power along with protection SP MCB`s. 1 No. Multifunction Meter with CT`s with LCD Display. All other eccessories reqd along with the above. Busbars 500 Amp 4 Pole busbar with coloured heat shrinkable sleeve. (Busbar density considered shall not be more than : 1A/Sqmm for Copper and 0.7A/Sqmm for aluminium ) Outgoings 01 No. 400 A 36 KA FP Moulded Case Circuit Breaker with microprocessor based adjustable over current, short circuit, earth fault protection with ON /OFF/TRIP indications. 01 No.160 A 18 KA FP Moulded Case Circuit Breaker with thermal megnatic based adjustable over current, short circuit, earth fault protection with ON /OFF/TRIP indications. 01 No.100 A 18 KA FP Moulded Case Circuit Breaker with thermal megnatic based adjustable over current, short circuit, earth fault protection with ON /OFF/TRIP indications. 04 Nos. 63/100 A 18 KA FP Moulded Case Circuit Breaker with thermal megnatic based adjustable over current, short circuit, earth fault protection with ON /OFF/TRIP indications. 02 Nos- 32 Amp 4 Pole 10 KA D curve MCB
Fabricating, Supplying, Installing, Testing and Commissioning of (Non TTA type) outdoor type (Weather Proof and Water Proof) with protection (IP-54) panel, complete including the following:sheet steel cubicle type panels fabricated from 14 guage thick CRCA sheet, dust and vermin proof, outdoor type distribution MV Panels with hinged lockable doors fabricated from 2mm thick CRCA sheet, suitable for 415V, 3 phase 4 wire 50Hz AC supply with rear / bottom access for cable alley and with segregated bus-bar chamber and including supplying and fixing following switchgears, meters and accessories, inter-connections, bonding to earth, bottom base channel of MS section not less than 100mmx50mmx5mm (thick). Fabrication shall be done in transportable section ,entire panel shall have a common earth busbar at rear with 2 nos earth stud cable alleys, cable gland plates powder coated painting of approved shade after antirust treatment (with min seven tanks ) and marking as specified. Switch boards complete as per schematic diagram:(Scope of work also includes installation of the same on suitable size of foundation / on MS angle iron frame work of size 50mm x 50mm x 6mm, 90 cm long legs out of which 45 cm duly grouted in cement concrete 1:2:4 (1 cement : 2 sand :4 stone aggrete 20mm) as per site requirement) The MCCB rating up to 250A shall have thermal megnatic based adjustable over current, short circuit protection and above 250A MCCB shall have microprocessor based adjustable over current, short circuit, earth fault protection. All MCCB`s shall be Ics = 100% Icu, with spreaders, rotary handle and pad locking arrangement. Control wires shall be of 1.1 KV 2.5 sq.mm FRLS copper wires and neatly bunched separately and adequately supported so as to prevent sagging and strain on termination. All concealed hinged doors and covers shall be provided with suitable flexible earthing connections. All panel shall be provided with names plates of black perplex in white Engraving and to be provided on both front and back side of the panels as safety feature and for proper identification of panel. The scope of work also includes of dismantling of existing LT Panels (i/c disconnection of incomer and outgoing feeders,earthing etc ) shifting, leading and storage at designated location for installation of the LT Panels and also making temporary arrangement so that supply to all the load being fed from existing panel is continued and not disturbed as per direction of Engineer -in-charge complete as required.( Material required for temporary connection to be arranged by contractor only, no extra claim shall be entertained for the same.) SUB DISTRIBUTION PANEL-(Lake Area) Incommer 01 No. 250 A 36 KA FP Moulded Case Circuit Breaker with microprocessor based adjustable over current, short circuit, earth fault protection with ON /OFF/TRIP indications. Metering and Indications 1 No. Digital Multifunction meters with basic parameters like frequency, KW, KVA, KVAR, etc. complete with CTs and Protection MCB. RYB Phase Indication Lamps and ON/OFF LED Indicating Lamps with 2 Amp. SP MCB for protection. Busbars 300 Amp 4 Pole busbar with coloured heat shrinkable sleeve. (Busbar density considered shall not be more than : 1A/Sqmm for Copper and 0.7A/Sqmm for aluminium ) Outgoings 02 Nos.100 A 18 KA FP Moulded Case Circuit Breaker with thermal megnatic based adjustable over current, short circuit, earth fault protection with ON /OFF/TRIP indications. 08 Nos- 63 Amp 4 Pole 10 KA D curve MCB
`Supplying, Installation, Testing and Commissioning of Air Circulator Fan, Class of Insulation for fan and regulator :Class I Rated Voltage :230V AC Speed Control Mechanism :Pull Cord Or String Based Control, Number of Blades :3 ,Material of Blade :ABS Blade Colour:White Fan Guard Material :Powder Coated Metal Wire Number of Speed Steps:3, Type of Fan Mounting:Bracket Mounted Fan For Wall Mounting :Oscillating, Type of Fan Motor :Non-Capacitor Type Fan Size (Mm ) :400.Minimum Air Delivery (CMM)-76`
Supply, Installation, Testing and Commissioning of 800 mm long 11 W 1100 lumens LED IP 65 Bollard , Square shape and hollow in between ,Weather-proof and rust-free luminaire ,High-efficacy LEDs for optimum energy consumption, Potted driver and accessories pre-wired up to terminal block, having base plate with holes for direct mounting complete with all accessories including preparation of finished CC foundation with suitable size HDPE pipe for cable entry and exit, electrical connections for incomming and outgoing cables etc complete as per requirement at site (The rate must include junction box/terminal box suitable for incoming and outgoing cables i/c termination and other accessories and suitable earthing system). Lumen Efficacy of LED )100Lm/W @ 4000 K color temperature ,PF =0.95, THD =10%,Input Voltage Range 140-280 V, 3 KV Inbuilt Surge protection and 10 KV External, IK07 Rating.
Supply, Installation, Testing and Commissioning of 16mm X 16mm of 5 meters length Mono Color CCT : 3000 K of 70 W Flexible and encapsulated LED Strip light with Non- Integral driver. The luminaire’s shall be made of Silicon extrusion with high-efficiency, high grade appearance, soft bend flexibility and Option of Top bend , the same shall be so designed. The luminaire shall have silicon glue between optical cover and LED chamber to ensure proper IP67 protection. Brand name shall be embossed / printed on each an every light fixtures. CCT 3000 K and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.The Non Integral driver shall be installed in suitable Junction Boxes IP 66/67 “weather proof”, for outdoor installation along with IP 67 Gland and lugs Cable Termination complete as required.
Supply installation,testing and commissioning of 9W LED BUSH LIGHT having Graphite grey powder coated integral aluminium housing.The Die-cast aluminium housing comprises Warm White (WW) COB LED and reflector.COB LED housing covered with die- cast aluminium ring with weatherproof gasket and toughened glass.LED Used shall be COB type CCT up to 3000K ±250K,IP65. Luminaire is wired with inbuilt driver with 5kV surge protection and should be constant current type with operating Voltage Range of 140 to 280V AC,PF)90,50Hz.Adjustable mounting bracket with spike should be provided for easy to focus the object.2 nos., Ø8mm holes should also be provided on adjustable mounting bracket for surface mounting. Luminare shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors, weather proof IP66/67 junction Box etc. as required.
Supply installation,testing and commissioning of 4000K Circular Mini Flood Light with Integral driver. The luminaire’s shall be made of Extruded aluminum housing powder coated with toughened glass in Dark Gray color.The complete luminaire has IP65 and IK06 protection and it comprises of high purity integrated poly carbonate Lens.The LEDs shall have minimum CRI =70 (White LED) and shall have SDCM=5. The luminaire shall have wattage 40W and shall deliver 3600 lumens. Beam angle of the Luminaire shall be 30 deg .Fixture shall operating temperature range of 0°C to 45°C. Input Voltage Range of 140 - 280V AC.. The luminaire shall have declared life of 50,000 burning hours at L70.Luminaire and Driver must be made in India with same brand. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with technical bid. LM80 , RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire. Brand name shall be embossed / engraded on each an every light fixtures. Luminare, Driver and controller should be with same make and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors, weather proof IP66/67 junction Box etc. as required.
Supply installation,testing and commissioning of IP67 18W Mono Colour LED Inground light with all channel ON. Fixture shall be made up of Aluminum Housing for better heat decapitation having IP66 Dust and Water Protection for Outdoor usage. The Luminaire should have multiple beam options of 11/15/30/60° to be used as per design requirement. The luminaire shall have declared life of 50,000 burning hours at L70. Luminaire should be capable of operating at 24VDC , with External IP66 24Vdc Driver. Luminaire and Driver should be Made in India. Luminare, Driver and controller should be with same make` and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors, weather proof IP66/67 junction Box etc. as required.The Non Integral driver shall be installed in suitable Junction Boxes IP 66/67 “weather proof”, for outdoor installation along with IP 67 Gland and lugs Cable Termination complete as required.
Supply installation,testing and commissioning of 7 W LED STEP LIGHT having non-corrosive cast aluminium body.Low power White LEDs (WH) covered with heat resistant frosted glass fixed to the housing with frame protection grill.LED Used shall be COB type CCT up to 5700K ,IP54. An operating Voltage Range of 140 to 280V AC,PF)90,50Hz. LED driver should be constant current type.he luminaire should have loop in loop out provision for power complete i/c termination as reqd complete i/c all civil job associated with it.
Supplying of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver e?ciency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver e?ciency )85%,THD ( 10% as per IEC 61000- 3-2 , P. F.=0.95, IP-66,IK-10, CRI )80, under voltage and over voltage protection, EMI-EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement.suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report,CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen e?cacy =120 (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). -60 W
Supply, Installation, Testing and Commissioning of 60W LED Dual Triangle Post Top pole mounted having System Lumens 7800 Lumens, IP66 Protection,IK 10 Rating , PF =0.95 and THD =10% , Housing Made of Aluminium Extrusion /die Cast Aluminum Housing, Powder coated with grey pure polyester powder, Diffuser is Poly carbonate, LED Life 50000 Hrs , Inbuilt Surge Protection 5 KV and 10 KV External Input Voltage Range 140-280 V.complete as per requirement at site /c termination as reqd complete .
Supply, Installation, Testing and Commissioning of 40 W LED Gate Light having System Lumens 4000 Lumens having system efficacy 120 Lumen Per Watt. IP66 Protection, , PF =0.95 and THD =10% , Housing Made of Pressure Cast Aluminum Housing , Diffuser is Tempered Glass , IK 07 Rating, LED Life 50000 Hrs , Inbuilt Surge Protection 4 KV and 10 KV External Input Voltage Range 140-280 V.complete as per requirement at site /c termination as reqd complete .
GATE LIGHT FIXTURES
Design, manufacture, supply, installation, testing and commissioning of outdoor type (WEATHER PROOF and WATER PROOF) external lighting feeder pillar of suitable size not less than 30 cm and upto 45 cm deep made out of M.S. sheet 2mm thick (14 SWG) duly compartmentalized, double door with locking arrangement (IP-54), duly fixed on MS angle iron frame work of size 50mm x 50mm x 6mm, 90 cm long legs out of which 45 cm duly grouted in cement concrete 1:2:4 (1 cement : 2 sand :4 stone aggregate 20mm) and having following accessories mounted inside the cubical panel i/c connection, inter connection with aluminium thimbles, earthling with two nos. earth studs duly painted with one coat of red oxide and two coats of superior quality enamel paint of approved shade complete etc. as reqd. Incommer a) 63/100 Amps, 415V, 16 KA, 4P MCCB with operating handle (Incomer) = 1 No Metering and Indications 1 No. Digital Multifunction meters with basic parameters like frequency, KW, KVA, KVAR, etc. complete with CTs and Protection MCB. RYB Phase Indication Lamps and ON/OFF LED Indicating Lamps with 2 Amp. SP MCB for protection. Busbar 150 Amp FP busbar with coloured heat shrinkable sleeve.(Busbar density considered shall not be more than :1A/Sqmm for Copper and 0.7A/Sqmm for aluminium ) b) 100 Amps. 415V, 3 phase AC, TP power contactor and Auto Manual Switch and Push button = 1 No. c) 63 A 4 Pole MCB complete with interconnections as required. - 10 nos d) Astronomical time switch of following configuration to be mounted in feeder pillars for automatic switching On and OFF of street lights at sun set and sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as reqd 3 output (1output per phase) and suitable for three phase supply.
Design, manufacture, supply, installation, testing and commissioning of outdoor type (Weather Proof and Water Proof) panel of suitable size made out of M.S. sheet 2mm thick (14 SWG) duly compartmentalized, double door with locking arrangement (IP-54), duly fixed on MS angle iron frame work of size 50mm x 50mm x 6mm, 90 cm long legs out of which 45 cm duly grouted in cement concrete 1:2:4 (1 cement : 2 sand :4 stone aggrete 20mm) and having following accessories mounted inside the cubical panel i/c connection, inter connection with aluminium thimbles, earthling with two nos. earth studs duly painted with one coat of red oxide and two coats of superior quality enamel paint of approved shade complete etc. as reqd. Incommer 32 Amp 4P MCB, 10 KA breaking capacity.- 1 no The above board shall be complete with phase indicating lights, at Incomer with all interconnections by min. 2.5 sq.mm. Copper wires. Busbar 63 Amp FP busbar with coloured heat shrinkable sleeve.(Busbar density considered shall not be more than :1A/Sqmm for Copper and 0.7A/Sqmm for aluminium ) Outgoing 06 Nos. 20 Amp 4P MCB, 10 KA breaking capacity. 02 Nos. 10 Amp 2P MCB, 10 KA breaking capacity. Space for Flexi light drivers/Inground Light
Supply and fixing of First Aid box as approved by St. John Ambulance Brigade / Indian red Cross conforming to IS 2217 - 1963
Fabrication, Supply and Erection of suitable feeder pillar box fabricated with 16 SWG CRCA sheet with powder coated painting duly providing 1 No. 63 Amp TP MCB as incomer, 1 No. 32 Amp 3 pole MCB for motor protection, 1 No. ML 6 contactor, 20 Amp astronomical timer, 32 Amp 5 pin metal clad socket. MCBs and metal clad sockets and contactors and timer. Suitable capacity of 3 pole contactor with interlocking facility for motor operation and necessary push button are to be provided.
Supplying, installation, Testing and Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency )85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4 5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP 66,IK-10, CRI )80 , under voltage and over voltage protection, EMI EMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver and electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with System lumen efficacy 105 (120 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C)- 200 W
Providing and fixing of following sizes of PVC Flexible Protective Cable Conduits suitable for outdoor applications, high compressive strength and good weathering properties along with connectors complete with conduit gland and all accessories required. 25 mm PVC Flexible Pipe
Providing and fixing of following sizes of PVC Flexible Protective Cable Conduits suitable for outdoor applications, high compressive strength and good weathering properties along with connectors complete with conduit gland and all accessories required. 32 mm PVC Flexible Pipe
Supply, handling, testing and commissioning of following sizes of 1.1 KV grade XLPE core insulated, extruded PVC inner sheath, armoured , extruded PVC outer sheath Copper conductor cables as per IS 7098 Part I ammended upto date. All complete as required and as per final instruction as given by E.I.C / Consultants. 4 C x 6 Sqmm XLPE Copper Armoured. Cable
Supply, handling, testing and commissioning of following sizes of 1.1 KV grade XLPE core insulated, extruded PVC inner sheath, armoured , extruded PVC outer sheath Copper conductor cables as per IS 7098 Part I ammended upto date. All complete as required and as per final instruction as given by E.I.C / Consultants. 4 C x 10 Sqmm XLPE Copper Armoured. Cable
Supply, handling, testing and commissioning of following sizes of 1.1 KV grade XLPE core insulated, extruded PVC inner sheath, armoured , extruded PVC outer sheath Copper conductor cables as per IS 7098 Part I ammended upto date. All complete as required and as per final instruction as given by E.I.C / Consultants. 4 C x 16 Sqmm XLPE Copper Armoured. Cable
Providing pair of duly tested rubber hand gloves as per IS :340715 suitable for working on 15 kV
ABC Type Fire Extinguisher Cap. 4 kg Filled with Mono Ammonium Phosphate Powder 90% confirms to IS 14609, Stored Pressure Type, UGTS Pressure Gauge, Gross Weight 8.9 Kg, Empty Weight 2.9 Kg, Can Height 530 mm, Diameter 150 ± 10mm, Discharge Time 24 Sec, Controllable discharge mechanism, Jet Range 5 Meters, Average Discharge is 90%, applicable on Class A,B and C and electrically started Fire, A Rating- 3A, B Rating 21B, Can Construction : Deep drawn and CO2 Mig welded, EPDM Rubber Hose with both end Aluminum clamped, Internal Coating - Epoxy Powder coating, External Coating - Pure Polyester Powder coating (UV Resistant), Brass forged valves with safety Pin is of SS material, Sheet metal thickness : 1.8 mm, ISI Approved IS 15683:2006
22.5 kg CO2 High Pressure Trolley mounted Fire Extinguisher, filled with Co2 Gas as per IS 15222, Control discharge mechanism fitted with 1 Meter Wire Braided Hose and Flat Horn with Diffuser Nozzle for dispersed discharge of CO2, Discharge Time 12 Sec, Average Discharge is 95%, Applicable on Class B, C and electrically started Fire, Fire Rating 21B, Internal coating is not applicable and External coating is of enamel spray painting, Powder Coated Handle, Valve Confirm to IS 3224 ISI Marked, CO2 Cylinder construction: hot spinning by seamless pipes and bearing ISI mark, Body confirms to IS 7285 and PESO APPROVED, Extinguishers conforming to IS 15683:2006 and ISI marked.
45 ltr. Mechanical Foam type Fire Extinguisher filled with AFFF Foam (6%), Applicable fire class AandB, Gross Weight 87 Kg, Empty weight 37 Kg, Can Height 1285mm, Diameter 300 mm, Controllable Discharge mechanism, Discharge Time 40-180 Sec, Jet Range 10 Meters, Average Discharge is 90%, Fitted with EPDM Hose with SS spring of 300mm to avoid kink (3 meter long) and Air aspirated Nozzle, CO2 gas Cartridge of 300 gm. (Confirms to IS 4947), Can Construction : Deep drawn and CO2 Mig welded, External Pure polyester (UV Resistant) and Internal Epoxy polyester powder coated, Brass forged cap, construction as per IS 13386:1992 and ISI Marked.
Supply, Installation, Testing and Commissioning of Window type Air conditioners complete with copper power cable upto 3 Mtr, wireless Remote, suitable for working between 180- 260V with low and high voltage cuto? and 50 hz ,1 phase AC supply capable of performing, cooling, dehumidification, air circulation, R-32/R-410A /R-407B Green Refrigerant with Scroll / rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB), antifreeze thermostat on the coil as a safety feature, complete with fixing including TandP and labour etc as required complete in all respect as specified of following capacity. Sound level of up to 50dB inside the room is acceptable. The unit shall be in confirmation with IS 1391 Part-I 2023 and CPWD Specification. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. The system shall be able to operate up to 50 degree (out door ambient temperature). 1.5 TR with Inverter 5 Star BEE rating
Supply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low and high voltage cuto? and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). 2.0 TR with 5 Star BEE Rating
Supply, Installation, Testing and Commissioning of Air Cooled Cassette type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), R-32/R410A/R-407 Green Refrigerant, wireless Remote, inbuilt drain pump, suitable for 400/230V, 50 Hz ,1 /3 phase AC supply, including surface /concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5.5 Mtr (IDU to ODU), copper power and control cable upto 5.5 Mtr (IDU to ODU) including drain pipe, the system shall be capable of performing cooling, dehumidification, Air circulation, filtration and ventilation of following capacity with Scroll/rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB) as specified. The system shall be able to deliver 100% of the rated capacity as per relevant IS Code. The lab testing reports as per IS: 1391 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) 2.5 TR with 5 Star BEE Rating
Supply, Installation, Testing and Commissioning of Air Cooled Cassette type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), R-32/R410A/R-407 Green Refrigerant, wireless Remote, inbuilt drain pump, suitable for 400/230V, 50 Hz ,1 /3 phase AC supply, including surface /concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5.5 Mtr (IDU to ODU), copper power and control cable upto 5.5 Mtr (IDU to ODU) including drain pipe, the system shall be capable of performing cooling, dehumidification, Air circulation, filtration and ventilation of following capacity with Scroll/rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB) as specified. The system shall be able to deliver 100% of the rated capacity as per relevant IS Code. The lab testing reports as per IS: 1391 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) 3.5 TR with 5 Star BEE Rating
Supply of Heat pumps system for hot water using heat energy source from ambient air to Hot water, of High e?ciency and energy saving operation, capable of heating water at 55° to 60° C with silent operation (the sound level should not exceed 65 dB). The Heat Pump shall have LCD display control panel with built in diagnostic and troubleshooting information and an inbuilt cycle for defrosting in case icing occurs on evaporator including all other mounting, fitting and controls, all interconnecing wiring/cabling between heat pump and electric panel etc complete in all repsect with but not limited to following specifications.Power Supply V/Ph/Hz : 400~440V/3 PH/50Hz. Suggested Maximum output water temperature in Deg C : 55 ° to 60° C, ambient temperature range in Deg C : -5 °C~45 °C , Type of Fan : Low Noise axial fan , Suggested Noise level: DBA (63 , COP: 3.0 to 4.0. Hot Water Storage Tank consisting of GI/MS/SS cylindrical shape clarifier tank. (inlet temperature of hot water storage tank 60- 65 deg.C) suitable for minimum 4 Kg /Sqm working pressure. Tank shall be provided with water flow meter, inlet / outlet, overflow, drain connection with MH cover, 6 mm thick tank, pressure relief valves, pressure gauge at inlet / outlet with isolation cock, thermometer at inlet / outlet, ball Valve, safety valve,check valve etc. The complete system to be tested to a pressure of 10 Kg/cm2 complete in all respects including temperature indicatiors, thermostat and other required accessories. Tank shall be insulated with 100 mm thick crown 150 grade and 50 mm rock wool pads of approved quality and cladded with 24 SWG aluminium sheet cladding. 200 LPH
Supply and installation of ventilation metal sheet rectangular air ducts, including seams, joints,hangers, supports, turning vanes, elbows and transformation complete with duct sealants and flexible connections (duct sealant and flexible connections to be fire rated where needed) and all necessary accessories all as specified and shown on drawings.
Supply and installation of metal-pvc-metal flexible duct connection, complete with all necessary accessories.
Supply Square Ceiling air diffuser complete with all fixings and accessories. Supply air 150X150 mm
Supply Square Ceiling air diffuser complete with all fixings and accessories. Return air 250X250 mm
Supplying, installation, testing and commissioning of 80 Ltrs. water storage capacity and 40 Ltrs/hr. cooling capacity full stainless steel body heavy duty water cooler, 4 Nos. taps complete with copper wound rotary compressor, Drain pipe etc. including mechanical and electrical connections with suitable size 3 core copper wire and plug complete as required.
`Supply, Installation, Testing and Commisioning of Water Filter/ Purifier UV Suitable for Online Purification with following specifications Pre Filter Pre Carbon block filter Post Carbon block filter Fully automatic operation with auto-on and Auto–Off facility`
SITC of Microprocessor based Intelligent Addressable Main Fire Alarm Control Panel with 1 Loop module and each loop capable of supporting not less than 250 devices (detectors and modules should be in any combination) : Loop length up to 1.5 km, 8` Color LCD touch screen display with bright colors to indicate alarms and events, 4 Nos of Integrated Ethernet Ports and 2 Nos of RS 485 for networking, 200 Nos of Soft programmable keys with status indicators for individual triggering of NAC Ouputs, evacuation speaker zones, AHU Modules, Damper switch, Smoke extraction Fans, Lifts.. etc. The Panel shall support 10000 history logs in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 24 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have seamless integration with EVAC certified Public Address System and shall be complete with all accessories . EN- VDS/ UL-FM Certification.
SITC of Intelligent Addressable Multicriteria detector with a combination of Optical and Thermal including mounting base, auto addressing feauture as required. Detetctor should have 2 inbuilt isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be EN-VDS/ UL-FM Certification. Approved
Supplying, installation, testing and commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.
Supplying, installation, testing and commissioning of addressable manual call point complete as required.
Supplying, installation, testing and commissioning of addressable horn cum strobe complete as required.
Supply, Installation, Testing and comissioning of Mixer amplifier Inbuilt Bluetooth for audio streaming, Supports audio playback from USB pen drive, 4 microphone/line inputs, plus music source input, Insert feature to use as a pre/power amplifier, Optional 2-tone chime generation for input 1, 40 A, Max. / rated 360 W / 240 W, 31 V (240 W), Approx. 10.5 kg, Connector Cinch, stereo converted to mono, Sensitivity 200 mV to 300 mV
Supply, Installation, Testing and comissioning of Tabletop Unidirectional Condenser Microphone Voltage range 12 to 48 V Current consumption (8 mA ,Sensitivity 0.7 mV @ 85 dB SPL (2 mV/Pa), Maximum input sound level 110 dB SPL, Distortion (0.6% (maximum input) ,Input noise level (equiv.) 28 dB SPLA (S/N 66 dBA ref. 1 Pa),Frequency response 100 Hz to 16 kHz Output impedance 200 ohm.
Supply, Installation, Testing and comissioning of 480W Booster amplifier , Battery voltage -24Vdc (max.10%deviation), Frequency response-60Hz to 15 kHz( plus 1/-3 db), Distortion (at rated out power ar 1 khz)- (3%, Inputs- XLR , Impendence-20k , Sensitivity-1V (mic inputs), S/N-)80 DB.
Supply, Installation, Testing and comissioning of Horn Loudspeaker made with ABS, waterand dust protected to IP 65 Sound pressure level at 15W/1W - 115/103 dB (SPL), Effective frequency range 500 Hz to 5 kHz, Rated power 15W.
Supply, Installation, Testing, commissioning of 5MP Dome Camera with 2.8-12mm Motorized Varifocal lens, 1/2.8` SONY - CMOS 5MP Active Pixel, Minimum Illumination - Color - 0.01 Lux @F1.2, Focal Length - 2.8mm - 12mm, Focus Range - 0.3m to infinity, Aperture (F#) - F1.6-F2.8, Iris Type - Motorized Varifocal Iris, IR Range - Up to 50m, IR Led Wavelength - 850nm, IR Switching - Auto/ Manual, Audio IN - 1, Audio OUT - 1, Two-way Audio -Supported, Audio Compression - G.726 and G.711g, Alarm In - 1 (Phoenix type connector), Alarm Out - 1 (Phoenix type connector), SD Card - Up to 512GB, Available Resolutions - 2592 x 1944, 2592 x 1520, 2048 x 1536, 1920 x 1080, `720p, D1, 2CIF, CIF, Max Resolution - 2592 x 1944, Bitrate - 128 kbps-16Mbps, Bitrate Type - CBR, VBR, Video Compression - H.265, H.264, MJPEG, Frame Rate - 1- 30fps, Shutter Speed - 1/15s - 1/100000s, Adaptive Streaming - Yes, ONVIF Profiles - S, G, and T, Edge Recording - Yes, Alarm Recording - Pre and Post, Motion Recording - Yes, Time Triggered - Yes, WDR True -WDR (120dB), SNR - )70dB, Storage - NAS, SD Card, Certifications - NDAA Compliant, BIS, CE, IP67, FCC Part-15 Subpart — B, ONVIF S, G and T,IK10,UL, NEMA 4X**, STQC Certified with OWASP ASVS 4.0L2, SIRA
Supply, Installation, Testing, commissioning of 5MP Bullet Camera with 2.8-12mm Motorized Varifocal lens, 1/2.8` SONY - CMOS 5MP Active Pixel, Minimum Illumination - Color - 0.01 Lux @F1.2, Focal Length - 2.8mm — 12mm, Focus Range - 0.3m to infinity, Aperture (F#) - F1.6-F2.8, Iris Type - Motorized Varifocal Iris, IR Range - Up to 50m, IR Led Wavelength - 850nm, IR Switching - Auto/ Manual, Audio IN - 1, Audio OUT - 1, Two-way Audio -Supported, Audio Compression - G.726 and G.711g, Alarm In - 1 (Phoenix type connector), Alarm Out - 1 (Phoenix type connector), SD Card - Up to 512GB, Camera Adjustment Angle - Pan: 0° to 360°, Tilt: 0° to 90° , Rotate: 0° to 360°, Available Resolutions - 2592 x 1944, 2592 x 1520, 2048 x 1536, 1920 x 1080, 720p, D1, 2CIF, CIF, Max Resolution - 2592 x 1944, Bitrate - 128 kbps-16Mbps, Bitrate Type - CBR, VBR, Video Compression - H.265, H.264, MJPEG, Frame Rate - 1-30fps, Shutter Speed - 1/15s 1/100000s, Adaptive Streaming - Yes, ONVIF Profiles - S, G, and T, Edge Recording - Yes, Alarm Recording - Pre and Post, Motion Recording - Yes, Time Triggered - Yes, WDR True - WDR (120dB), SNR - )70dB, Storage - NAS, SD Card, Certifications - NDAA Compliant, BIS, CE, IP67, FCC Part-15 Subpart - B, ONVIF S, G and T,IK10,UL, NEMA 4X**, STQC Certified with OWASP ASVS 4.0L2, SIRA
Supply, Installation, Testing and comissioning of 32 Channel NVR with 4K Support and 2 HDD Slot, 32 IP Channel Inputs: HDMI, 1/1 Audio I/O and 2/1 Alarm I/O, 12MP, 8MP, 5MP, 4MP, 3MP, 2MP, 720p, D1 and CIF Recording Resolution, 4x 4K/ 10x 3MP/16x 1080p Local Decoding, 4 SATA HDD Support (Maximum 10TB Capacity per Slot), Save Storage Space with Adaptive Recording and Camera-wise Recording Retention, SMS and Email Notification, Video Pop-up and Alarms, 512 Mbps Throughput - 256 Uplink, 256 Downlink, NAS Support: 2 NAS (CIFS, NFS), Mobile Viewer Application Should Support Calling from Mobile App Feature Where a Mobile Number Can be Added Per Camera in the Device and The User Can Directly Call a Concerned Person by Just One Click on Camera View from Mobile(without any SIM card in NVR), The device should be capable of acting as a Master device and should be able to Add,View,Playback and Configure at least 20 other connected slave devices (NVRs) camera`s from the Local View via HDMI, without need of any Server/workstation., BIS, FCC.
Supply, Installation, Testing, commissioning of 2MP PTZ Camera, Image Sensor 1/ 2.8” CMOS, Minimum Illumination Color: [email protected], 0Lux with IR Shutter Speed 1/15s to 1/10000s, Day and Night Yes, Wide Dynamic Range 120dB, Optical Zoom 38x, Digital Zoom 16x, ocal Length 4.4 mm – 169.4 mm, Zoom Speed Approximately 6s from wide to tele at Max Speed, Aperture Range F 1.6 – F4.9, IR Range Up to 300m, IR irradiance Angle Adjustable by Zoom, Video Compression H.265/H.264/M-JPEG, Video Bitrate 128kbps 16Mbps, Audio Compression G.726 ,G.711 a-law and u-law, Audio Bitrate 128kbps 16Mbps IMAGE, Max Resolution 2MP – 1920×1080 5MP – 2592 x 1944, Stream Profiles Four streams support 5MP, Profile 1:- 2592 x 1944p/ 2592 x 1520/ 2048 x 1536/ 1920 x 1080/ 720P/ D1/ 2CIF/ VGA/ CIF/ QCIF @30fps (H.264/H.265), Video Analytics Motion/No Motion Detection, View Tamper Detection, Trip/No Trip Detection, Object Intrusion/Zone Intrusion, Loitering, Missing/ Object Counting, Abandoned Object, Audio Exception, Alarm In, Protocol TCP/IP, UDP, HTTP, HTTPs, DHCP, DNS, DynDNS, RTP, RTCP, RTSP, RTSPS, PPPOE, SMTP, NTP, SNMP, HTTPS, FTP, SMTP, 802.1x , IGMPv2and v3, ICMP, IPv4,IPv6,QoS Layer 3, CIFS,SSH, ARP, Communication Interface 1 RJ45 10/100 Self Adaptive Ethernet Port, Built-in Micro SD card slot up to 512GB, Power Supply 24VDC 2.5A , AC(Optional), Power Consumption Max 25W, Protection IP67.
Supply, Installation, Testing and comissioning of PC Client Intel i7 processor with clock speed- minimum 3.0GHz, RAM8 GB and Expandable. Window 10 or Window 2016 Server or Unix based Edition .Minimum 1TB . LAN Interface 10/100/1000 Mbps Ethernet.).. Mouse Optical . USB port at front and Software of cameras.
Supply, Installation, Testing and comissioning of Switch should be Web Manged, Should have 8 port 1000BASE-T with 4 Port 1000BASE-T PoE PoE power budget 160 Watt or higher, Maximum Per port PoE Power 30 WattIEEE 802.3 10BASE-T Ethernet, IEEE 802.3u 100BASE-TX Ethernet,IEEE 802.3ab 1000BASE-T Ethernet, IEEE 802.3az EEE support,IEEE 802.3x flow control,IEEE 802.3z 1000BASE-X,IEEE 802.1p CoS,IEEE 802.3af PoE, IEEE 802.3at PoE Plus, IEEE802.1Q VLAN Tagging, Minimum 8 VLAN supportPort based VLAN, IEEE802.3ad link aggregation should be MAC based Switching Capacity 16 Gbps,Packet buffer 192KB,MAC address support 4K Jumbo frame support 9K, Should support loop detection,Should support Broadcast storm control QoS Support (WRR and strict priority) Port based QoS 20 Multicast group or higher, Maximum power consumption 72W,Operating temperature 0°C to 40°C Storage Temperature -40°C to 70°C Certification: CE, FCC, C-Tick, , LVD EN60950-1, ROHS compliant.Should be built-in IEEE 802.3az Energy Efficient Ethernet (EEE)
Supply, Installation, Testing and comissioning of Layer-2 POE plus Gigabit Ethernet 1RU chassis with 24 PoE 10/100/1000 BaseT ports and 4 Gigabit SFP ports. Includes an internal AC power supply 370W atleast or higher power budget) with a power cord, manuals access card, and RJ-45 to DB-9 adaptor.The Access Switch should have 4 ports of 1 G SFP.The Access Switch should provide Non-Blocking switch fabric capacity of 56 Gbps or more. L-2 switch should provide wire-speed packet forwarding of 41 Mpps or more. L-2 Switch should support min 16K MAC addresses and min 4000 active VLANs.
Supply, Installation, Testing and comissioning of 9U outdoor IPV5 rated rack with 2 side FAN with 3 socket PDU with 15 AMP DP for power surge safty. With pole mount accessories. Rack should be certified.
Supply, Installation, Testing and comissioning of 3 KVA Online UPS Overvoltage cut-off device (OVCD),Support for up to 42 AH external battery cabinets, Generator Compatible with Wide Input. Wide Input Voltage window (110 – 280Vac) for IndianEnvironmental Condition andfor Optimized BatteryPerformance. UPS would support SNMP Mnagaer and web browser On Line With 1 hour Backup
Supply, Installation,Testing and Commissioning of 24 x 10/100/1000BASE-T Interface (inbuilt 6kV surge Protection, 2 x 10G Copper 4 and 10G SFP plus Uplink, Internal/External Redundant Power supply Support, Physical stack of up to 8 units, 80 Gbps per device physical stacking bandwidth, Switching capacity 168 Gbps or non-blocking architecture. Packet forwarding rate 125 Mpps. RAM/DRAM: 2GB and Flash/SSD : 256MB, Packet Buffer Size 2 MB, 2 Internal Fans, MAC Address Table 16K, Support IPv4 and IPv6: OSPFv2/v3, IEEE 802.3ah, IEEE 802.1ag, ITU-T Y.1731, ERPS, PBR, LLDP/LLDP-MED, UDLD/DULD, SPQ, WRR, Strict plus WRR, WDRR, WRED, GVRP, BPDU Filtering, Root Guard, Loop Guard, Loopback Detection, HOL Blocking Prevention, RSPAN/SPAN, L2PT, UDLD or equivalent, Dying Gasp, 4 x Smart fans, Operating Temp 0 to 50 °C, Storage Temperature -20 to 70°C, Certifiate: CE, FCC, UL, MTCTE/TEC-ER (as notified vide Indian Telegraph (Amendment) Rules, 2017), ISO 27001, IEC-62443-4-1:2018 or Equivalent. Make - D Link
Supply, Installation,Testing and Commissioning of Wireless Harware Based Controller for Access Points with 1× 2.5GbE RJ45 port, 1× USB Type-A port.
Supply, Installation,Testing and Commissioning of 24 Port Gigabit Switch with Fiber Uplink 4 x RJ45/SFP 10/100/1000Mbps Combo Ports, 802.3at PoE plus and 802.3af 370watt Power Budget. Switching Capacity: 128 Gbps, MAC Address Supply, Installation,Testing and Commissioning of Table 8K, Packet Forwarding Rate: 41 Mpps, Flash Memory 64 MB, DRAM Size 256 MB DDR3, 2 x Internal Fans for Cooling and Air Circulation, CPU Speed 500MHz. MAC Address Table 8K entries, IGMP Snooping, IGMP v1/v2 Snooping, IGMP v3 awareness, 256 IGMP groups, 64 static multicast addresses, IGMP per VLAN, IGMP Snooping Querier, Loopback Detection, 802.3ad Link Aggregation: groups/8 ports per group, LLDP, LLDP-MED, jumbo Frame 10,000 bytes, 802.1D STP, 802.1W RSTP, 802.1s MSTP, 802.3x Flow Control, HOL Blocking Prevention, Port Mirroring One-to-One/Many-to-One, Multicast Filtering, Configurable MDI/MDIX, MLD snooping v1/v2 (256 groups). IEEE 802.3az. SPQ and WRR, IPv6 ND, DHCP snooping and DHCP server screening. ARP spoofing prevention. 802.1X port-based authentication. 802.1X RADIUS and local server database authentication. Port security to secures the access port based on MAC address. Broadcast, multicast, and unicast storm control. Traffic Segmentation, SSH and SSL for IPv4 and IPv6. DoS attack preventio, IP plus MAC plus Port Binding, LLDP and LLDP-MED. Compact CLI, Telnet Server, TFTP Client, Configurable MDI/MDIX, SNMP v1/v2c/v3, SNMP Trap , Backup/upgrade firmware, Upload/download configuration file, BootP/DHCP Client, System Log, Max. 500 log entries, SNTP, ICMP v6, IPv4/v6 Dual Stack , DHCP Auto Configuration, Time setting, SNTP, RMONv1, Trusted host, Dual image, Dual configuration. Operating Temperature -5 to 50°C, Storage Temperature -20 to 70°C, Operating/Storage Humidity 0% to 95% relative humidity. Power input 100 to 240 V AC 50/60 Hz internal universal power supply, EN 550 32, EN 55024, EN 61000 3 2, IEC 61000 4 2, EN 61000-3-3, IEC 61000 4 3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11, EN 62368-1, CISPR 22, FCC Part 15, ICES 003, IEC 63000, UL 60950-1, and CAN/CSA C22.2 No. 60950-1-07. Certifiate: CE, FCC, UL, MTCTE/TEC-ER (as notified vide Indian Telegraph (Amendment) Rules, 2017), ISO 27001, IEC-62443-4-1:2018 or Equivalent.
ISupply, Installation,Testing and Commissioning of EEE 802.11ax with a data rate of 1800 Mbps, configured in a 2x2 plus 2x2 setup. Additionally, it should feature high output power for both 2.4GHz and 5GHz frequencies, and support Power over Ethernet (PoE) compliant with 802.3at standards. must support IEEE 802.11b for 11 Mbps, 802.11g for 54 Mbps, 802.11a for 54 Mbps, 802.11n for 300 Mbps, and 802.11ac for 867 Mbps wireless data rates. must support IEEE 802.11ax for 1200 Mbps on the 5GHz band and 574 Mbps on the 2.4GHz band. Support 1024QAM on both of 2.4GHz and 5GHZ. The operation of be within the 2.42.5GHz and 5.155.85GHz frequency bands to comply with worldwide regulations. supports enhanced security features, including WPA/WPA2/WPA3 for both Personal and Enterprise use, RADIUS client integration, and Cipher negotiation. be equipped with the following interfaces: Power Jack, Factory Reset Button, one RJ45 console port, and LAN ports supporting Power over Ethernet (PoE). comprehensive network management capabilities, including HTTP, HTTPS, Software Controller, Hardware Controller, SNMP support, Telnet, Email Notification, and Secure SSH Telnet. Extensible Authentication Protocols (EAP), including EAP, EAP-TLS, EAP-TTLS/MSCHAPv2, PEAPv0/MSCHAPv2, PEAPv1/EAP-GTC, and EAP-SIM. four dual-band internal antennas, with specifications of 3.2 dBi for 2.4 GHz and 4.3 dBi for 5 GHz. Additionally, it should have a maximum output power of 23 dBm for 2.4 GHz and 26 dBm for 5 GHz. 802.1x, RADIUS Server, POP3 and LDAP. Multi-Tenant and Role-Based Administration. Wireless Resource Airtime Fairness, Connect Limit, Aging Out, ACL RSSI and Band Steering, Wireless MAC ACL, and WLAN Partition. ARP Spoofing Prevention, Wireless Intrusion Protection, and Bandwidth Optimization. Captive Portal with industry-standard authentication. MAC-based access filtering and WLAN partitioning, Wi-Fi Multimedia Quality of Service (QoS), Traffic Control Uplink and Downlink limit. Ethernet traffic statistics and WLAN traffic statistic. Load balancing to optimize performance between Access Points. FCC, CE Certifications. Product Should Approved from TEC under Mandatory Testing and Certification of Telecom Equipment as notified vide Indian Telegraph (Amendment) Rules, 2017. Make - D Link
Supply, Installation, Testing and Commissioning of Unified Outdoor Enterprise, dual radio, 5 GHz and 2.4 GHz 11ax min 2x2 plus 2x2 MIMO, min 2401 Mbps (5GHz) plus min 574Mbps(2.4GHz), Security features WPA3 and Enhanced Open security, RADIUS client, Cipher negotiation and Support External / Internal RADIUS server and Support OFDMA , Support Wi-Fi 6, IEEE 802.3af and 802.3at, Band Steering, Minimum 2 x dual-band Internal Antennas: Min 3dBi for 2.4 Ghz and 3dBi for 5 Ghz. Support 1024QAM on both of 2.4GHz and 5GHZ, Support 2.4~2.5GHz and 5.15~5.85GHz frequency band, 11ax, 2x2 plus 2x2, high output power design for 2.4GHz/5GHz, 1 x RJ45 console port, 1 x 2.5G Ethernet (PoE) LAN, factory reset, power input, SNMP v1, v2c, and v3, and be capable of integration with both hardware and software controllers. Additionally, function as an individual access point if required, with internal Radius server support during individual installation. Fast Roaming Support with 802.11k, 802.11v, and 802.11r and Support Passpoint Wi-Fi (hotspot 2.0) Seamless cellular-to-Wi-Fi carryover for guests. Access Point Should Support Radio and Modulation Schemes for BPSK, QPSK, 16QAM, 64QAM, 256QAM, up to 1024QAM with OFDMA and in complied with ac and b/g/n compliant equipments. Operating / Storage Temperature -30 to 60 °C, / -30 to 65 °C, Operating / Storage Humidity 10% to 90%, / 5% to 95%. Direct power and Power over Ethernet both options. Wi-Fi CERTIFIED™ Certificate and Certificate lists: www.wi-fi.org/certification/programs, Support Wi-Fi Multimedia, by enabling this feature it will improve the user experience for audio and video applications over a Wi-Fi network. Access Point Wi-Fi CERTIFIED for WMM, W-Fi Agile Multiband. Certifications CE, FCC, Wi-Fi, IEC 60601-1, UL, IP68. OEM ISO 45001, ISO 27001, ISO 9001, ISO 14001 and ISO 14064-1,Certificate for Industrial Cyber Security Capability (Like - IEC-62443-4-1:2018 or Equivalent) Make - D Link
Supply, Installation, Testing and Commissioning of Patch Cord 1 Mtr. TIA/EIA 568C.2 standard. 24 AWG, multi-strands. conductor metal made from bare copper. Insulation material high density polyethylene. patch cord jacket LSZH. Conductor size: 24 -26 AWG stranded bare copper, Jacket: FR-PVC, Mechanical Characteristics – Plug, Operating life: Minimum 750 insertion cycles, Contact blade: Copper Alloy, Contact plating: 03Mµ” Gold, Electrical Characteristics – Plug, Dielectric withstanding Voltage: 1000VDC or 700 VAC, Insulation resistance: )500 MegaOhms @ 1000V DC/min, Operating temperature: - 20 Degree C to 75 Degree C, Clear Polycoarbonate for RJ-45 And Clear PVC for Boot Material, factory molded Boot, RJ-45 standards: ISO/IEC 60603-7-4 and FCC 47 part 68, UL Application : PC UL94-V-0, UL Listed and ETL Listed Certified, Patch cord plug gold plated. Contact blade of plug made from copper / alloy. Insertion cycle 750 times. Temperature range should support from 10° Celsius to 60° Celsius. Vertical flame propagation IEC 60332-1-2, Acid Gas Emission Test – IEC 60754 - 1 and 2, Smoke Density Test – IEC 61034-2. Manufacturer ISO 9001, ISO 45001, ISO 9001, ISO 14001 and ISO 14064-1. OEM for the cable Box and all copper Accessories from same OEM.
Supply, Installation,Testing and Commissioning of PATCH CORD LC-LC SM DUPLEX LENGTH- 1m, 9/125µm Single mode G652D, Duplex Type, (EIA/TIA, IEC, ANSI). Physical Contact (PC) connectors return loss ) 45 dB. Ultra Physical Contact (UPC) connectors return loss ) 50 dB. Angled Physical Contact (APC) connectors return loss ) 60 dB. Repeatability ( 0.2dB 1000 times Mating Cycle. Working Temperature –10°C ~ plus 70°C, Storage Temperature –20°C ~ plus 70°C. All Passive of the same make. (Copper, Fiber and Racks).
Supply, Installation,Testing and Commissioning of LIU 06 Port Rack Mount - Loaded (LC ) SM, 1U height, 19-inch rack mountable. Fiber optic LIU should include with LIU Box itself, Adapter Panel, Adapters and Pigtail as per requirement. Adapter panel - Cold Steel, 1.5mm Thickness. Rubber fiber slotted bracket built-in, metal splice shelf to protect the fibers. 4 Fiber spools Built-In for 900um tight buffered Fiber Storing. Optical Fiber Pigtail – SC Type 1 Meter Provide a field installable Single mode SC pigtails to terminate fiber optic cables from cable-to-cable, cable-to-equipment and equipment-to-equipment. Utilize a UPC polishing on the tip to provide high yield during installation. Meet TIA/EIA 568.C.3 standards for repeatability. Buffer diameter 900um Tight buffer, Minimum bend Radius: Install :30mm, Retention Strength: 20N, Cable: 900um Buffered. SM fiber pigtail, the cable type shall be HDPE/LSZH with a diameter of 3.0mm / 2.0mm. Insertion Loss (Max) (0.3 db Max, Return Loss )/= 50 db for UPC. Connector ferrule Ceramic, SC Type Simplex Type, Cable Color Yellow. Repeatability ( 0.2dB 200 times Mating Cycle. Working Temp. -10 deg. C to plus 70 deg. C, Storage Temp. -20 deg. C to plus 70 deg. C
Supply, Installation,Testing and Commissioning of Wall Mount Rack, 9U x 500 W x 500 D indoor rack for switch Mounting with Fan and power Strip, PDU, Hardware Mounting Kit. Front Glass Door (tinted, Toughened) with Lock and Key. 2 pairs of 19` Mounting Rails with U-Marking. Provision to mount cooling fans Unit / 90 CFM /230V AC (1 No) on the top panel. Rack shall Conforms to DIN 41494 OR equivalent ISO Standards. Welded Side Walls, CRCA steel Frame and powder coated with highest quality standards. 19” Mounting angles made of formed steel. Depth adjustable mounting slots for verticals provide better mounting flexibility and maximizes the usable mounting space. Top and bottom Panel with ventilation and cable entry facility. Rack Powder coated finish with pretreatment process meeting all industry standards. Grounding and Bonding Options. 100% assured compatibility with all equipment conforming to DIN 41494 (General industrial standard for equipment). Rack Welded to Frame Top and Bottom Cover, Vented and Field Cable entry exit cut outs. Standard Accessories: 1U Cable Manager (1), Hardware Pkt of 20 (1 Pkt), 6 Socket 5 Amp. Power Distribution Unit (1 No), Standard Color : Grey, Static Load : 40 kgs. The OEM must possess international certifications for ISO 45001, ISO 9001, ISO 14001, ISO 27001, ISO 14064-1. The OEM should have Indian-based operations for a minimum of 20 years, demonstrating a long-standing presence and experience in the industry.
Supply, Installation,Testing and Commissioning of 17U Closed Rack / Width 600 / Depth 1000 indoor rack for switch Mounting with Fan and power Strip, PDU, Hardware Mounting Kit. Depth adjustable mounting slots for verticals provide the better mounting flexibility maximizing the usable mounting space. Openings/Cut outs for field cable entry from Top and Bottom of the Rack. Provision to mount the cooling fans on the top panel. Powder coated finish with pretreatment process meeting all industry standards.Grounding and Bonding Options. Conforms to DIN 41494 or equivalent standard. 17U Closed Rack / Width 600/ Depth 1000. Lockable Toughened Glass Door, Steel Single, Steel Dual. Equipment Mounting : DIN Standard 10mm Sq. Slots / Direct M6 Tap. 19” Mounting angles made of formed steel. Top and Bottom Cover : Welded to Frame, Vented and Field Cable entry exit cut outs. Mounting Option : Castor wheels (Front 2 wheels with Break and rear without break) Or Levelers or Base plinth. Accessories: Doors and Side Panels, Power Distribution Units, FHU with 4 FAN 360CFM, Jacking Feet, Mounting Hardware-(Pack of 20), Vertical Power Distribution Unit with 12 x 5/15 sockets Round Pin, 230 Volts AC, 32 Amp with Plug, Horizontal Cable Manager-1U-Loop, Casters Set of 4, Adjustable Levelers set of 4. Standard Color: Black or Grey. Static Load: 300 kgs. The OEM must possess international certifications for ISO 45001, ISO 9001, ISO 14001, ISO 27001, ISO 14064-1. The OEM should have Indian-based operations for a minimum of 20 years, demonstrating a long-standing presence and experience in the industry.
`Supply , installation , testing and commissioning of EV Charging station 3.3KW capacity(1X3.3 KW), AC universal Charger complete with following specification. 3.3kW ACWallbox Charger composed of main control unit, protection and metering` Power Connection : P plus N plus PE Rated power - 3.3KW Number of Output - 1 Sockets Individually Output current (per gun) - 16 Amp. , Single Phase Input Votltage - 230 Vac (± 10%), 50Hz (± 10%) Output Charging Outlet - Plug IEC60309 Socket Status Indicator : Power ON, Charging ON and Fault Power Factor - =0.99 Efficiency - =94% Push Button - Emergency Stop User Authorisation - APP and QR Code Operating Temperature - -5°C to 60°C, Storage Temperature - -5°C to 70°C Humidity - 5% to 95% without condensation Network Connectivity - SIM card / WiFi based network connectivity ,GSM/ GPRS Metering and Billing - Available through Software suit Altitude : =2000m Charging Operation - Scan QR Code / Mobile App Electrical Protection/Safety parameters- Input/Output protection - Over / Under voltage protection, Overload protection, Short Circuit protection, Current leakage protection, Grounding protection, Over Current/ Under Current Protection. Shell Material - Polycarbonate Protection level - IP54, IP 55 Cooling - Natural Cooling Installation : Wall mounted , Stand Mounted
Supply , installation , testing and commissioning of EV Charging station 7.4 KW capacity, AC type 2 output complete with following specification. Rated power - 7.4kW ( Power connection P plus N plus PE) Number of Output - 1 nos of AC type 2 Gun Output current (per gun) - 32Amp Input Votltage - 230 Vac (± 10%), 50Hz (± 10%) Single Phase Output Charging Outlet - Type 2 Output Voltage - 230V AC Power Factor - =0.99 Efficiency - =94% Display - 20x4 Character LCD Display with backlight. Push Button - Emergency Stop User Authorisation - APP and QR Code Ambient Temperature - -20°C to 55°C, -20°C to 60°C Storage Temperature - -40°C to 70°C Humidity - (95%, Non condensing Network Connectivity - SIM card / WiFi based network connectivity Metering and Billing - Available through Software suit Charging Operation - Scan QR Code / Mobile App Electrical Protection/Safety parameters- Input/Output protection - Over / Under voltage protection, Overload protection, Short Circuit protection, Current leakage protection, Grounding protection, Surge protection, Over Current/ Under Current Protection. Shell Material - Hot dip galvanised iron sheet , Hot-dip galvanized steel sheet Protection level - IP54, IP 55 Cooling - Natural Air Cooling Regulation as per - IEC 61851-1 Charging Mode - 3 Certification - ARAI Communication Protocol - OCPP v 1.6 Length of charging gun - 5m Installation : Wall mounted , Stand Mounted
Supply, Installation, Testing and comissioning of 65` 4KUHD resolution LED Display with Android 11, 400 nits brightness, Cortex A55 1.3Ghz processor, Mali G31 MP2, Open GLES3.2, 2 GB DDR RAM, 16 GB Memory, Wifi Type support both 2.4 and 5G Standard, Dolby Audio, Built in Wifi and Cromecast, HDMI CEC, HDMI ARC, Built-in Bluetooth, Hotel mode, Meeting Mode,20W built in speakers, HDMI 2.0 X 2, AV X 1, USB X 2, RJ45 X 1, SPDIF Out x 1,24/7 operational.
Supply, Installation, Testing and comissioning of 65` 4KUHD resolution LED Display with Android 11, 400 nits brightness, Cortex A55 1.3Ghz processor, Mali G31 MP2, Open GLES3.2, 2 GB DDR RAM, 16 GB Memory, Wifi Type support both 2.4 and 5G Standard, Dolby Audio, Built in Wifi and Cromecast, HDMI CEC, HDMI ARC, Built-in Bluetooth, Hotel mode, Meeting Mode,20W built in speakers, HDMI 2.0 X 2, AV X 1, USB X 2, RJ45 X 1, SPDIF Out x 1,24/7 operational. Supply, Installation, Testing and comissioning of 5 Mtr HDMI cable Connectors at both ends
Supply, Installation, Testing and Commissioning of Patch Panel 24 Port 1U Size loaded with 24 port RJ-45 IO. Mounts in standard 19 inch racks. Cable manager for improvement management. Patch panel suitable for Category 6 keystone. SPCC and Black Color. Rear support bar material SPCC and Black Color. RJ-45 jack housing PBT plus Glass fiber UL94V-O and Contact brackets PBT plus Glass fiber UL94V-O. Rj-45 contact material phosphor bronze with nickel plated and plug contact area finish with 50 micro-inches Gold plated. Contact resistance maximum 20 miliohm. Operating Temperature -10° Celsius to 60° Celsius. Life of RJ-45 Jack 750 cycles minimum @ 500 VDC. ETL Verified / UL Listed. Manufacturer ISO 9001, ISO 45001, ISO 9001, ISO 14001 and ISO 14064-1.
Supply, handling, testing and commissioning of following sizes of 1.1 KV grade FR PVC insulated, extruded PVC sheath, unarmoured, Copper conductor flexible cables as per IS 1554 Part I and IS 694 with latest amendments including laying in existing HDPE pipes /ducts/PVC Rigid and flexible conduits complete as per site requirements and as per final instruction as given by E.I.C / Consultants.The Scope shall also include the Termination/ Connection of flexible cables at Fitting and Panel End complete with lugs insulation tape, approved sealing epoxy compound,double compression brass cable glands, effecting gland connections and effecting terminal connections to the equipment complete as required. 6 C x 4.0 sqmm Copper conductor. (For Mini Flood/Bollard )
Supply, handling, testing and commissioning of following sizes of 1.1 KV grade FR PVC insulated, extruded PVC sheath, unarmoured, Copper conductor flexible cables as per IS 1554 Part I and IS 694 with latest amendments including laying in existing HDPE pipes /ducts/PVC Rigid and flexible conduits complete as per site requirements and as per final instruction as given by E.I.C / Consultants.The Scope shall also include the Termination/ Connection of flexible cables at Fitting and Panel End complete with lugs insulation tape, approved sealing epoxy compound,double compression brass cable glands, effecting gland connections and effecting terminal connections to the equipment complete as required. 3 C x 2.5 sqmm Copper conductor. (For Step /Flexi/Bush lighting/In groung Light etc)
Providing and fixing SS towel rail 600 mm long.
Providing and fixing UPVC 6 kg pressure 110 mm x 110 mm P trap complete in all respect.
CP Brass towel ring
Providing and fixing Health faucet.
PRIVIDING AND FIXING OF 6KG PRESSURE DOOR BEND (110 MM DIA) COMPLETE IN ALL RESPECT. MAKE: FINOLEX, SUPREME, PRINCE ETC.
PRIVIDING AND FIXING OF 6KG PRESSURE PLAIN TEE 110 MM DIA COMPLETE IN ALL RESPECT. MAKE: FINOLEX, SUPREME, PRINCE.
PROVIDING AND FIXING OF 6KG PRESSURE PLAIN Y JUNCTION 110 MM DIA COMPLETE IN ALL RESPECT.MAKE: FINOLEX, SUPREME, PRINCE.
PROVIDING AND FIXING OF 6KG PRESSURE COUPLER 110X100 COMPLETE IN ALL RESPECT. MAKE: FINOLEX, SUPREME, PRINCE.
PROVIDING AND FIXING OF SS FLOOR JALI DOUBLE STAINLESS 110 DIA COMPLETE IN ALL RESPECT. MAKE: ESSESS, JAQUAR, CERA.
PROVIDING AND FIXING OF 6KG PRESSURE CLEAN OUT PLUGE (COP) 110X100 COMPLETE IN ALL RESPECT. MAKE: FINOLEX, SUPREME, PRINCE.
Providing and fixing of SS grating with frame of 150 mm dia or rectangular soze 2-3 mm thick as per approved shape and size complete in all respects.
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required..
Supplying, installation, Testing and Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffesuser and construction as per IS :10322 with driver as per the requirement with Driver efficiency )85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short and Open circuit protection ,THD ( 10% , P. F.=0.95, IP20, CRI )80 , UGR (Unified Glare Rating) ( 19, Flicker free (flicker should be below 5%), life time (LED,Driver and electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin),SDCM (Standard Deviation Color Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.).Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required. System lumen effiacy =105 and (120 lm/Watt output. LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.(Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C)- Powder coated die cast /Extruded aluminum Body including trim.- 15 W.
Supply, Installation, Testing and Commissioning of 800 mm long 11 W 1100 lumens LED IP 65 Bollard , Square shape and hollow in between ,Weather-proof and rust-free luminaire ,High-efficacy LEDs for optimum energy consumption, Potted driver and accessories pre-wired up to terminal block, having base plate with holes for direct mounting complete with all accessories including preparation of finished CC foundation with suitable size HDPE pipe for cable entry and exit, electrical connections for incomming and outgoing cables etc complete as per requirement at site (The rate must include junction box/terminal box suitable for incoming and outgoing cables i/c termination and other accessories and suitable earthing system). Lumen Efficacy of LED )100Lm/W @ 4000 K color temperature ,PF =0.95, THD =10%,Input Voltage Range 140-280 V, 3 KV Inbuilt Surge protection and 10 KV External, IK07 Rating.
4.5 kg CO2 High Pressure Portable Fire Extinguisher, filled with Co2 Gas as per IS 15222, Gross Weight 16.4, empty weight 11.9 Kg, Control discharge mechanism fitted with 1 Meter Wire Braided Hose and Flat Horn with Diffuser Nozzle for dispersed discharge of CO2, Discharge Time 12 Sec, Average Discharge is 95%, Applicable on Class B, C and electrically started Fire, Fire Rating 21B, Internal coating is not applicable and External coating is of enamel spray painting, Powder Coated Handle, Valve Confirm to IS 3224 ISI Marked, CO2 Cylinder construction: hot spinning by seamless pipes and bearing ISI mark, Body confirms to IS 7285 and PESO APPROVED, Extinguishers conforming to IS 15683:2006 and ISI marked.
Supply, Installation, Testing and Commissioning of Window type Air conditioners complete with copper power cable upto 3 Mtr, wireless Remote, suitable for working between 180- 260V with low and high voltage cuto? and 50 hz ,1 phase AC supply capable of performing, cooling, dehumidification, air circulation, R-32/R-410A /R-407B Green Refrigerant with Scroll / rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB), antifreeze thermostat on the coil as a safety feature, complete with fixing including TandP and labour etc as required complete in all respect as specified of following capacity. Sound level of up to 50dB inside the room is acceptable. The unit shall be in confirmation with IS 1391 Part-I 2023 and CPWD Specification. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. The system shall be able to operate up to 50 degree (out door ambient temperature). 1.0 TR with Inverter 5 Star BEE rating
Supply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low and high voltage cuto? and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). 1.5 TR with 5 Star BEE Rating (inverter cooling only)
Supply of Heat pumps system for hot water using heat energy source from ambient air to Hot water, of High e?ciency and energy saving operation, capable of heating water at 55° to 60° C with silent operation (the sound level should not exceed 65 dB). The Heat Pump shall have LCD display control panel with built in diagnostic and troubleshooting information and an inbuilt cycle for defrosting in case icing occurs on evaporator including all other mounting, fitting and controls, all interconnecing wiring/cabling between heat pump and electric panel etc complete in all repsect with but not limited to following specifications.Power Supply V/Ph/Hz : 400~440V/3 PH/50Hz. Suggested Maximum output water temperature in Deg C : 55 ° to 60° C, ambient temperature range in Deg C : -5 °C~45 °C , Type of Fan : Low Noise axial fan , Suggested Noise level: DBA (63 , COP: 3.0 to 4.0. Hot Water Storage Tank consisting of GI/MS/SS cylindrical shape clarifier tank. (inlet temperature of hot water storage tank 60- 65 deg.C) suitable for minimum 4 Kg /Sqm working pressure. Tank shall be provided with water flow meter, inlet / outlet, overflow, drain connection with MH cover, 6 mm thick tank, pressure relief valves, pressure gauge at inlet / outlet with isolation cock, thermometer at inlet / outlet, ball Valve, safety valve,check valve etc. The complete system to be tested to a pressure of 10 Kg/cm2 complete in all respects including temperature indicatiors, thermostat and other required accessories. Tank shall be insulated with 100 mm thick crown 150 grade and 50 mm rock wool pads of approved quality and cladded with 24 SWG aluminium sheet cladding. 200 LPH
Supplying, installing, testing and commissioning of INLINE DUCT Mounted Fresh Air and Toilet exhaust FANS with blower, Insulation Class F . Enclosure class IP 44 .Casing made of ABS (FR) .Backward-curved centrifugal impeller using PA66(FR) .ABS (FR) connection box .External rotor motor with low temperature rise .Motors equipped with automatic reset thermal overload protection. Voltage-230(V/Hz)with flexible duct connection.(Wiring for the same shall be measured in wiring Sub Head) Exhaust Air inline Air Flow-1600(m³/h) -Fan Size 315mm (12 inch )
Supplying, installing, testing and commissioning of INLINE DUCT Mounted Fresh Air and Toilet exhaust FANS with blower, Insulation Class F . Enclosure class IP 44 .Casing made of ABS (FR) .Backward-curved centrifugal impeller using PA66(FR) .ABS (FR) connection box .External rotor motor with low temperature rise .Motors equipped with automatic reset thermal overload protection. Voltage-230(V/Hz)with flexible duct connection.(Wiring for the same shall be measured in wiring Sub Head) Fresh Air inline ( 185 CFM)- 1600(m³/h) -Fan Size 315mm (12 inch )
Supply, installation, testing and commissioning of 10 TB Surviellance Hard Disk complete etc. as required..
Supply, Installation,Testing and Commissioning of 1G SFP Transceiver single-mode 9/125um fiber 10km, Transceiver should be Small Form-Pluggable (SFP) form factor and compatible with quoted switches. IEEE 802.3z 1000BASE-LX Gigabit Ethernet, SFP (Small Form Pluggable), LC Duplex, IEEE 802.3 compatible, 1310 nm, Single-mode fiber (9/125µm), Operating Temperature: 0 to 70 °C, Storage Temperature: -40 to 85 °C, Compliance: MSA Compliant, Switch and Fiber Modules should be Form Same OEM. Module shall be is in compliance with the essential requirements and other relevant provisions of the directives 2014/30/EU (EMC), 2014/35/EU (LVD) and 2011/65/EU (RoHS). EMC: EN 55032:, Class B: EN 55024, Safety: EN 62368-1, EN 60825-1, EN 60825-2, RoHS: Restriction of Hazardous Substances EN IEC 63000.
Supply, Installation,Testing and Commissioning of Category 6 Unshielded Twisted 4 pair Armoured Cable, Conductor 23 AWG Solid Bare Electronic Grade Copper. Insulation material Polyethylene, Inner jacket PVC of Grey Color, Thickness of Inner Jacket 0.65 to 0.70mm. Outer Jacket FR PVC in Black Color, Outer Jacket Thickness 0.85mm (Nom.). Armouring: Aluminium Wire, Rip Cord, Filler: HDPE. Outer Diameter 9.50 mm and Conductor Diameter 0.56 mm (23 AWG). Cable support Conductor Resistance 93.5 OHMS/1000Mtr@20°c. Mutual Capacitance of cable ( 5.6nF/100m. Max Resistance Unbalance of cable 5% Max. Capacitance Unbalance of cable should max 330pF/100m. Cable support Worst Case cable skew ( 45nS/100m, NVP: 69%. Capacitance Unbalance 330PF/100M Max. Charcteristics Impendance 100±15%OHMS. Supports Gigabit Ethernet (1000 base-T) standard and Operates at bandwidth of 250MHz. Supports transmission of high-speed data signals on LANs, compliant with TIA/EIA-568-C.2, should operate on bandwidth up to 250MHz, channel performance up to 70 meters. Operating Temperature from -20° to plus 60°C. Supports Gigabit Ethernet (1000 baseT) standard. Cable should come with printed sequential Length Counter on each meter. Cable Attenuation (( 36 db/100m), Pair – to – pair and PS NEXT, ELFEXT and PSELFEXT, Return Loss, ACR and PS ACR. OEM for the cable Box and all copper Accessories from same OEM. OEM for the cable Box and all copper Accessories from same OEM. OEM should have Indian based operation at least for a period of 20 plus years and should have an Annual Turnover of Rs. 500 Crores and above in any of last three consecutive Audited Financial years. OEM International certification for the ISO 45001, ISO 9001, ISO 14001, and ISO 14064-1.
Supplying, installation, testing and commissioning of Wall mounted and/or surface standing (Machine front cover Stainless Steel 304 Body Enclosure, Black MS Powder-coated to avoid rust and corrosion. Approx machine size length x width x height 500 mm x 75 mm x 300 mm. Number of UV tubes 3 x 15w Philips make, separate ballast for each tube, so if any tube is fused, other two are working. High-performance 8000 Plus Hours of Life. 3 UV Light 15W 220V AC ±10% to attract maximum Mosquitoes, Insects in 500 Sq Ft area with an electric grid and glue pad tray at the bottom to collect dead insects as per specification
Providing and fixing of Air Curtain of following sizes having automated magnetic or mechanical sensor operation. Air curtain fabricated out of 304 stainless steel , having double blower, single phase, Max. Air Velocity at Nozzle-21 m/sec, Noise Level dB- 50-70 dB,RPM (Max/Min) 2700/2100 as per following specifications complete in all respects and as per directions of Engineer-in-charge Air Curtains 3 ft (900 mm)
Providing and fixing of Air Curtain of following sizes having automated magnetic or mechanical sensor operation. Air curtain fabricated out of 304 stainless steel , having double blower, single phase, Max. Air Velocity at Nozzle-21 m/sec, Noise Level dB- 50-70 dB,RPM (Max/Min) 2700/2100 as per following specifications complete in all respects and as per directions of Engineer-in-charge Air Curtains 4 ft (1200mm)
Providing and fixing of Air Curtain of following sizes having automated magnetic or mechanical sensor operation. Air curtain fabricated out of 304 stainless steel , having double blower, single phase, Max. Air Velocity at Nozzle-21 m/sec, Noise Level dB- 50-70 dB,RPM (Max/Min) 2700/2100 as per following specifications complete in all respects and as per directions of Engineer-in-charge Air Curtains 6 ft (1800mm)
Design, Composition, Supply and Installation of Led emergency light Material: Aluminium box plus PMMA board Size: 360*200mm Features: Overcharge protection Light source: 3W led lights Light color: White led Voltage: AC90-260V 50/60Hz, AC110V~60Hz, AC220V~50Hz Battery:Ni-Cd1.2V Duration time: 90Mins or 3Hours Charging time: 24hour Automatically Power switch Finish: Double-side side printing
Dome lit dustbin
3 seater concrete benches
Sinages
Providing and fixing Furniture with all necessary Accessories and fixtures required in the site, to include providing samples for approval from engineering in charge. The given rates include the cost of all materials labour, necessary tools, ladders, scaffolding etc complete in all respect as per technical specifications mentioned in the drawing and quotations: 12 no. queen Size bed Providing, placing and supplying of queen bed: Overall Size:Width - 1570 mm Depth — 2046 mm Height — 901 mm Material:3Bed Structure consist of metal frames made of M.S. Channels in 1.0mm Thickness. Horizontal plinths and bottom plinth are made of 25 mm Thick Prelaminated Particle Board 1S:12823 Class E1 (as per EN13986).Plinth support assembly is made of M.S. 25 mm square pipe in 1.2 mm thickness. Head board is made of 18 mm thick PrelaminatedParticle board IS:12823 Class E1 (as per EN13986) with 2mm edge banding glued with Hot Melt EVA glue. Tail board is made of 18 mm thick Prelaminated Particle board IS:12823 Class E1 (as per EN13986) with 0.8mm edge banding glued with Hot Melt EVA glue.Side rail is made of 18 mm thick Prelaminated Particle board 1S:12823 Class E1 (as per EN13986) with 0.8mm edge banding glued with Hot Melt EVA glue.Mattress panels of Bed are made of 18 mm thick Prelaminated Particle 1S:12823 Class E1 (as per EN13986) with 0.8mm edge banding glued with Hot Melt EVA glue. Hardware :The high quality hardware are used.Construction:Knock Down construction.Packets :2packet.Finish :.18 mm thick Prelaminated Particle Board 1S:12823 Class E1 (as per EN13986) is in Imperial Oak shade.The Product should be Certified by Green Pro. 24 no. Bedside Table Providing, placing and supplying of bedside table: Overall Size :Depth — 461.0 mm Width — 460.0 mm Height — 510.0 mm Material:Body panels of Bed side table are made of 18 mm thick Prelaminated Particle Board 1S:12823 Class E1 (as per EN13986) .All the exposed edges are edge banded with 0.8 mm thick PVC edge banding glued with Hot Melt EVA glue.Drawer front are made of 18 mm thick Prelaminated Particle board 1S:12823 Class E1 (as per EN13986). Hardware:The high quality hardware used like Roller slides, Hinges , minifix, dowels is of make Hettich.Construction:Knock Down construction. Packets :1 packet.Finish :.18 mm thick PrelaminatedParticle Board 1S:12823 Class E1 (as per EN13986) is in Imperial Oak shade.The Product should be Certified by Green Pro. 2 no working table Supplying and placing in position Main Table of the following specifications. Its size shall be 1500 Width x 750 Depth x 743 Height.Top shall be of 18 mm thickness made of PLT board with 2 mm Edge banding. Wenge and savannah Maple PLT board shall be used. The Understructure shall be in pre-laminated panels made with PLT boards . 2- Drawerand 3 - Drawer storage units with different combinations to support tops made with 18 mm PLT boards of different colours.Modesty and back panels made with 18 mm PLT boards. The pedestals / storages shall be fitted with necessary locks. 4 no. Revolving Chair with headrest Providing, supplying and placing of High Back Chair. SEAT ASSEMBLY: The seat is made up of 1.5±0.1 cm thick hot-pressed plywood upholstered with fabric and moulded polyurethane foam. SEAT SIZE: 51.8cm (W) x 49.7cm (D) BACK ASSEMBLY: The Back is injection moulded in glass filled Polypropylene which is 2 upholstered with Mesh fabric. The back consist of adjustable Lumbar support made of injection moulded Polypropylene having an adjustment of 5.0 10.1 cm. BACK SIZE: 47.9 cm(W) x 66.9 cm (H) HIGH RESILIENCE (HR) POLYURETHANE FOAM: The HR polyurethane seat foam is moulded with density 45 plus /-2 kg/m and hardness 14 ± 2 kgf as per IS:7888 for 25% compression. ARMRESTS (ADJUSTABLE):The height adjustable armrest is made of Polypropylene and can be adjusted to 6.010.1cm height it also has swivel and To and Fro adjustment with moulded PU armtop ACTIVE BIO-SYNCHRO MECHANISM: The adjustable tilting mechanism is designed with the following features 360° revolving type Front-pivot for tilt with feet resting on ground and continuous lumber support ensuring more comfort Till tension adjustment can be operated in seating position 5 position Tilt limiter giving option of variable sit angle to the chair Seat/back tilting ratio of 1:2 The mechanism housing is made up of HPDC Aluminium and black powder coated (DFT 40 to 60 micron) HEADREST The Headrest sub-assembly is made up of injection moulded glass filed Polypropylene which is upholstered with moulded HR polyurethane loam and fabric has an adjustment of 3.00.1cm The complete headrest assembly is retro fic to the main chair PNEUMATIC HEIGHT ADJUSTMENT: The pneumatic height adjustment with an adjustment stroke of 10.0±0.3cm. PEDESTAL ASSEMBLY: The pedestal is injection moulded in black 30% glass-filled Nylon and fitted with 5 nos. twin wheel castors. The pedestal pitch-center dia is 166.1±0.5 cm.(76.1 ± 1.0 cm. with castors). TWIN WHEEL CASTORS: The twin wheel castors are Injection moulded in black Polyamide having 6.01 0.1cm wheel Diameter. WIDTH (W) - 76.0cm DEPTH (D) - 76.0cm HEIGHT (H) - 114.0 cm- 123.5cm SEAT HEIGHT - 43.5 - 54.0cm The Product should be Certified by Bifma Level 2 and Green Guard. 1 no. Reception table Supplying and placing in position Reception table of the following specifications. Work Surface - Made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping. Access Flap along with a Gromett is provided on work surface for wire management Wire Management - Power box made with 0.8 mm thick CRCA (IS: 513), with switch plate (8 plus 3 Module cut out provision for Anchor Roma) which is fixed with worktop along the width at Access Flap position. Modesty Panel and Side Skirting - Made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping. Understructure - Made of 18mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping TOP shelf - Made of 18mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping. Hinge Door plus Drawer unit - Made of 18mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping. **Drawer bottom is made of 5.5thk MDF whiteboard Handle is provided for ease of opening. HDU and Drawer is provided with cam lock for security. Essential Accessories - Wire Riser made of 0.8mm CRCA (IS-513) is provided for proper wire management. Organizer Plate made of 1.2mm CRCA (IS-513) is provided for magnetic sticky notes. Bag Hanger Hook made of 1.2mm CRCA (IS-513) is provided for bag hanging. Length - 2400mm Depth - 1770mm Height - 740mm 1 Revolving Chair: Providing, supplying and placing of High Back Chair SEAT/BACK ASSEMBLY: The cushioned seat assembly consists of seat base moulded in glass-filled Poly-amide, moulded Polyurethane foam and upholstered with high stretch knitted polyester fabric. The Back is injection moulded in glass filled Polypropylene which is upholstered with Mesh fabric. The back consist of adjustable lumbar support made of injection moulded Polypropylene having an adjustment of 3.0 ±0.1 cm. * Mesh Back Size : 45.5 cm. (W) x 54.0 cm. (H) * Seat Size : 48.5 cm. (W) x 49.0 cm. (D) HIGH RESILIENCE (HR) POLYURETHANE FOAM: The HR polyurethane foam used in seat and back cushion is moulded in Density Min 48 kg/m³, and hardness load 15 ± 2 kgf as per IS:7888 for 25% compression. TILT MECHANISM, SPINES and SPINE CONNECTOR: The seat and back are firmly connected to the base frame and are cantilevered in such a way that it gives a multi-dimensional movement possibility just with a simple lean on the sides or back, without need for complex manual adjustments. The cantilevered seat offers impact cushioning while sitting and synchronises with the back movement during posture changes. The `S` shaped spines moulded in high strength glass-filled Poly-amide and the spine connector moulded in glass-filled Poly-amide form the back-spine structure involved in multi-dimensional recline motion. The variable tilt angle recline motion can be adjusted with 3 position Tilt Limit feature which is inbuilt in seat base and the tension (return force) is user weight dependent. ADJUSTABLE ARMRESTS: The assembly consists of armrest housing sliding over the armrest structure, both moulded in glass-filled Poly-amide. The height adjustment feature is button operated having adjustment of 6.6±0.5cm. The Armrest Top is made up of integral skin PU moulded over plastic inner moulded in glass-filled Poly-amide. PNEUMATIC HEIGHT ADJUSTMENT: The seating height can be adjusted with a pneumatic gas-lift having an adjustment stroke of 9.2 ± 0.3 cm PEDESTAL ASSEMBLY: The pedestal is injection moulded in glass-filled Poly-amide and fitted with 5 nos. twin wheel castors. The pedestal is 66.0±0.5 cm. pitch centre diameter and 76.0±1.0 cm. with castors. TWIN WHEEL CASTORS: 5 nos. twin wheel castors are injection moulded in Poly-amide having 5.0±0.1cm wheel diameter and assembled to the pedestal. Width: 76.0cm Depth: 76.0cm Height: 101.0-109.5cm Seat Height: 44.5-53.8cm The Product should be Certified by Bifma Level 2 and Green Guard. 12 no. Single Bed Providing, placing and supplying of single bed: Overall Size :Length - 2060.0 mmWidth - 1131.0 ram Height - 945.0 mm Material:Bed Structure consist of metal frames made of M.S. Channels in 1.0 mm Thickness.Horizontal plinths and bottom plinth are made of 25 mm Thick Prelaminated Particle Board.Head board is made of 18 mm thick Prelaminated Particle board with imported H.D.F. foil wrapped decorative trims fixed to it.Tail board is made of 18 mm thick Prelaminated Particle board with imported H.D.F. foil wrapped decorative trims fixed to it. Side rail is made of 18 mm thick Prelaminated Particle board with imported H.D.F. foil wrapped decorative trims fixed on to it.Mattress panels of Bed are made of 18 mm thick Prelaminated Particle Board with all the exposed edges are edge banded with 0.8 mm thick PVC edge banding. Construction :Knock Down construction.Packets : 1 Bed in 1 packets. Finish :18 mm thick Prelaminated Particle Board is in Walnut shade. Metal frames are powder coated in shade Mat Black to the thickness of 50 microns( plus -10).The Product should be Certified by Green Pro. 12 Bed Side Table with single bed Providing, placing and supplying of bedside table: Overall Size : Width - 900 mm Depth - 605 mm Height - 718 mm Material: Body panels are made of 18mm thick Prelaminated Particle Board. All the exposed edges are edge banded with 0.8 mm thick PVC edge banding Hardware: The high quality hardware used like Slide Roller, rastex 15, wooden dowels are of Hettich make. Construction: Knock Down construction. Packets: 1 packet Finish: Prelaminated Particle Board is in Imperial Oak shade.The Product should be Certified by Green Pro. 14 no. 6 seater dining table with tempered glass top Providing, placing and supplying of dining table: Finish Color: Brown Warranty: 1 Year Warranty 12mm thick glass top is fixed with in a cavity on a hidden MDF layer with solid understructure and legs made of rubber wood 72 no. Dining chairs with tempered glass top dining table Providing, placing and supplying of chair: Overall Size : Length : 45cm Width : 55cm Height : 88.5cm Seating Height : 48cm LEATHER/PVC/FABRIC: PU. FRAME MATERIAL: METAL plus PLYWOOD. LEG MATERIAL: rubber wood 6 no. Wooden 6 Seater Dining Table Providing, placing and supplying of dining table Dimensions W x H x D (cm) 116.8 x 77 x 75 Finish Color: Brown Warranty: 1 Year Warranty Primary Material: Wood Primary Material Subtype: Sheesham Wood 6 no. Wooden 4 Seater Dining Table Providing, placing and supplying of dining table Dimensions W x H x D (cm) 117 x 75.94 x 75.93 Finish Color: Brown Warranty: 1 Year Warranty Primary Material: Wood Primary Material ubtype: Sheesham Wood 60 Chair Providing Fixing of high back in MDF 4 no.2 seator Sofa: Providing, placing and supplying of 2 seater sofa: Dimensions W x H x D (cm) - 153 x 90 x 82 Upholstery Material- Fabric plus Syn Leather Seatback: · Under structure: Under structure is made up of plywood and pinewood members. Plywood is 12±1mm thk. under structure is made by gluing, nailing and stapling. contact between the metal springs and the seat foam. This prevents seat foam from tearing. Complete purpose. Non woven fabric is stapled on the seat structure frame above the spring assembly to avoid direct 3.8mm is mounted on the seat structure using plastic spring mounting clip for support and additional cushioning 22x40mm, 22x75mm and 16X35mm without having major knots and defects on the surface. Zigzag spring of dia. [moisture resistance and termite proof as per IS:303]. Pinewood are of cross sections 22x64mm, 34x64mm · Foam: Seat is made of PU foam with density 28 kg/m3 of 75mm thickness with a two top layers of supersoft kg/m3 of thickness 6mm. Backrest top is glued with foam of density 28kg/m3 and 25mm thickness. 28kg/m3 and 10mm thickness and sides and the entire backrest are glued with the PU foam with density 60 PU foam with density 32 kg/m3 of 25mm thickness each. Seat front is glued with PU foam with density · Upholstery: Seat upholstery is made in polyester fabric and Black non-woven cloth with zipper for inserting non-woven of 30GSM with partitions. This laminated fabric is used on the upper backrest only. sandwitched laminated foam of density 32kg/m3 of 10mm thickness between a layer of fabric and white the loose seat foam. Backrest upholstery is made up of a combination of Polyester Fabric and Leatherite .2 no.2 Coffee Table : Providing, placing and supplying of Victoria Coffee table: Materials and SIZE : Material: Plywood plus MDF plus Solid wood legs Color : Dark Wenge Top Material: Plywood plus MDF Frame Material: Plywood plus MDF Leg Material: Solid wood ( Rubber wood) Shoe material: Polypropylene Mode of Supply Storage: NA Top Dimension: 1200X600X18 Height: 455 Thickness of frame: 18 Thickness of understructure Legs: 68 ( plus /- 5) Weight / unit (KG): 22 KG ( plus /- 4) Overall LxWxH: 1200X600X455
Supply and erection of Ornamental pole of 4 mtr. height made out of galvanized Mild Steel tubes having 1000mmx114mmx4mm dia at Bottom and 3000mmx75mx4mm dia at top fitted with decorative cast aluminium embellishment at middle and Decorative cast aluminium embelishment at bottom of dia 175 mm at middle and 305 mm at bottom. Pole should have a locked and non theft arrngment service window containing 6 Amp MCB and 4 way 25 Amp connector , pole should be with with base plate of 250x250x12mm including cost of nut and bolts of 500 mm x 16 mm Jtype , earthing studs, and all accessories as supplied by the manufacture including Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, over a bed of PCC 1 :5: 10 of required dimensions for poles of as per manufacturers specifications complete in all respects and as per directions of Engineer-in-charge. The Poles should be primer coated and painted with polyurethane paint.
Supplying, installation, Testing and Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency )85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4 5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP 66,IK-10, CRI )80 , under voltage and over voltage protection, EMI EMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver and electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with System lumen efficacy 105 (120 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C)- 200 W
Supply, Installation, Testing and comissioning of 22U Equipment Rack with provision for housing all control equipment with front and rear door, Blower for cooling and proper locking arrangements and as per the specifications, complete in all respect upto the entire satisfaction of Engineer - in - Charge of the work..
Supplying, Installation, Testing and Commissioning of DND and MMR INDICATOR 1M plus 1M BELL PUSH complete with followin:-Lampholder with two built-in LEDS, green and red. Can be used as out of room visual signal with double notification: do not disturb and make up the room -Enables the resident to inform hotel staff of the room status2.Two settings are possible: - Do not disturb - Please clean the room3.INDICATORicator lamp and bell push`
Providing pair of duly tested rubber hand gloves as per IS :340715 suitable for working on 15 kV.
Design Supply, Installation and commissioning of Compact Prefabricated FRP made packaged Sewage Treatment Plant of capacity 50 KLD complete in all respects including, civil, mechanical and electrical works with comprehensive Operation and Maintenance of 2 years complete in all respect.
Percentage BoQ
BoQ_Ver3.0
Bidder Name :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
[10.31.1.1]Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. 1.1. In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) Acid and alkali resistant tile [Through Rate]
[10.31.2.1]Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. 2.1. In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) Acid and alkali resistant tile [Through Rate]
[10.37.1]Providing and fixing of Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1. 25 mm thick [Through Rate]
[10.38]Providing and fixing of Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. [Through Rate]
[10.49.1]Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : 1. Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. [Through Rate]
[10.50.1]Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 1. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. [Through Rate]
[10.51]Providing and fixing granite stone in all shades 15mm to 18 mm thick in skirting /dado, risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of Granite including labour for fixing cramps pins and dowels etc. [Through Rate]
[10.52.1]Providing and laying machine cut, mirror polished, Italian Marble stone flooring laid in required pattern in linear portion of the building all complete as per architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 1. 18 mm thick Italian Marble stone slab, Perlato, Rosso verona, Fire Red or Dark Emperadore etc. [Through Rate]
[10.58]Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. [Through Rate]
[10.60]Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. [Through Rate]
[10.63.2]Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 2. Size of Tile 600x600 mm [Through Rate]
[10.69.2]Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand and manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). 2. Size of Tile 600x600 mm [Through Rate]
[10.69.4]Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand and manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). 4. Size of Tile 1000x1000 mm [Through Rate]
[10.7]Providing and laying of conglomerate floor 50mm thick cement concrete topping 1:2:4 [Through Rate]
[10.70.2]Extra for grouting the joints of floor tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. 2. Size of Tile 600x600 mm [Through Rate]
[10.71.2]Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand and manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). 2. Size of Tile 600x600 mm [Through Rate]
[10.71.4]Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand and manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). 4. Size of Tile 1000x1000 mm [Through Rate]
[10.75]Providing and laying 50mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design and shape, laid in required colour and pattern over (BIS 15658:2006) and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. [Through Rate]
[10.76]Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design and shape, laid in required colour and pattern over (BIS 15658:2006) and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. [Through Rate]
[10.99]Providing and fixing covel stone/garden stone of size 150 mm x 150 mm laid in 20 mm thick cement mortar 1:3 including grouting the joint with white cement and matching pigment complete in all respect (Covel/Garden stone to be as per manufacturer`s specifications to be got approved from Engineer-in-charge) [Through Rate]
[11.17]Providing and fixing of chicken wire mesh for avoiding cracks in plaster with necessary nail/screws etc. complete in all respect to the entire satisfaction of engineer-in-charge [Through Rate]
[11.5.3]12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) [Through Rate]
[11.5.4]12 mm cement plaster of mix : 4. 1:6 (1 cement: 6 fine sand) [Through Rate]
[11.7.1]20 mm cement plaster of mix : 1. 1:4 (1 cement: 4 fine sand) [Through Rate]
[12.1.1.1]Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or dash fastener shall be paid separately). 1.1. Second class teak wood [Through Rate]
[12.107]Providing Aluminium Jali of thickness 7mm thick with openings - 75mm X 75mm of including anodizing and fixing in frame with cost of screws etc. complete. [Through Rate]
[12.12.1]Providing and Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1. 1.5 mm thick [Through Rate]
[12.132.1]Providing and fixing factory made uPVC white colour fixed glazed windows/ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape and size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware`s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing and direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 1. Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area up to 0.75 sqm) [Through Rate]
[12.136.4]Providing and fixing factory made uPVC white colour sliding glazed door comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape and size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) crescent lock (if required), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame and sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware`s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing and direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 4. Three track three panels sliding door with fly proof S.S wire mesh (Two Nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqm up to 5.00 sqm) [Through Rate]
[12.143]Providing and fixing Fibre Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fibre glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. [Through Rate]
[12.144.1]Providing and fixing to existing door frames. 1. 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. [Through Rate]
[12.157.1.2]Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : 1.2. For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron) [Through Rate]
[12.157.2.2]Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : 2.2. For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) [Through Rate]
[12.158.2]Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. 2. Pre-laminated particle board with decorative lamination on both sides [Through Rate]
[12.172.2]Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540-F and ISO 11600 2. Up to 10 mm depth and 10 mm width [Through Rate]
[12.173]Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in-charge. [Through Rate]
[12.177.1]Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 1. With toughened glass panes of 6 mm thickness (weight not less than 15 kg/sqm) [Through Rate]
[12.3.3.1.2]Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 3.1.2. 2nd class teak wood 50 x 20 mm [Through Rate]
[12.36.1]Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 1. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws [Through Rate]
[12.7.1.1]Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) 1.1. Second class teak wood 35 mm thick shutters [Through Rate]
[13.30.2]Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 2. Hot finished seamless type tubes [Through Rate]
[13.37.1]Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 1. 80x1.25 mm M.S. laths with 1.25 mm thick top cover [Through Rate]
[13.41]Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). [Through Rate]
[13.42.1]Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. 1. M.S. tube [Through Rate]
[18.20]Providing and laying Gypsum panel partitions 100 mm thick with water proof Gypsum panels of size 666x500x100 mm, made of calcite phosphor Gypsum fixed with tongue and groove, jointed with bonding plaster as per manufacturer’s specifications in superstructure above plinth level up to floor IV level. Gypsum blocks will have a minimum compressive strength of 9.3 kg/cm2 [Through Rate]
[20.36]Making connection with the existing G.I. branch main up to 40 mm size including cutting and threading pipe etc., complete excluding cost of tee and long screw, but including cartage of material to site. [Through Rate]
[20.71.1]Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 1. 48" (1200mm) [Through Rate]
[20.76.9]Design, Supply and erection of transformer of standard make Required 25 KVA 11/0.433 KVA rating outdoor type 11 KVA V.C.B, panel, G.O. switch, H. Pole , H.T metering panel, APFC panel, battery charges, 11 KVA substation, entire cable network from G.O. switch to H.T metering equipment and from H.T metering to Transformer. From transformer to main to L.T, panel earthling, safety equipment, fenced enclosure for transformer, and any other contingent thereto complete in all respect as per approved make and directions of Engineer-in-charge as per respective capacity. 9. 250 KVA [Through Rate]
[20.84]Providing and fixing of insulated rubber matting suitable for 11 KV installation 1 M x 2 M x 12 mm thick (IS code 15652-40091) as per specification complete and as per directions of Engineer-in-charge [Through Rate]
[20.86]Supply, erection, testing and commissioning of G.O. Switch two poles, with blade, pin 6 insulators operating handle with GI pipe 25 mm class B complete in all respects. [Through Rate]
[20.89.10]`Designing, Supply and erection of DG set of capacity given below with noise controlled devices acoustic of suitable rating, testing and commissioning of diesel generating set, radiator cooled, 3 phase, 4 wire, 50 cycles 415 plus (-)1% volts AC alternator coupled directly through a set of flexible coupling on a common MS fabricated base frame with diesel engine complete with suitable size incoming cable from generator to change over/AMF panel, making 2nd incoming cable connection from transformer, outgoing cable connection from changeover/ standard panel, making second incoming cable connection from transformer, outgoing cable connection from changeover / STD panel to incomer of motor starter panel, fenced enclosure with platform for DG sets complete as per following detailed scope and specifications and directions of Engineer-in-charge. The rating should be at 1500 RPM. a) Diesel Engine b) Alternator c) Battery 24 V. d) Base Plate. e) suitable sq mm suitable core copper cable upto 40 metres. f) Tools, standard panel g) Metering set 415 VAC-1 set (Amp. meter, Volt Meter, ASS, VSS, Phase Indicator, control fuse, frequency meter, CT`s) h) Metering set 60/5A/110V (Amp. Meter, Volt Meter) i) Overload protection for DC-1 No. j) Battery Charger 24V DC k)Copper bus bar of suitable size l) KWH meter 96 sqmm size m) Starting fuse button and key switch9on/off) n) Indicating lamps for low lubricated oil pressure, high coolant temperature, set running, load on, Dc control and other required accessories complete in all respects to the satisfaction of Engineer-in-charge` 10. 250 KVA [Through Rate]
[21.84.2]Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 2. Size 450 mm X 600 mm inside (with 455 mm x 610 mm cover and frame single seal pattern I weighing 38 kg with C.C. topping) [Through Rate]
[21.85.2]Extra for every 0.30 metre depth of Inspection chamber 2. 450 mmx 600 mm inside [Through Rate]
[21.87.1.1]Constructing brick masonry road gully chambers as per standard drawings (as per sizes given below) including dressing of beds and sides of chambers to exact profiles, 15cm thick lime concrete 16:24:100 (as per specified in item No.10.6) in foundations 1st class brick work laid in cement sand mortar 1:5, 40 mm thick cement concrete 1:2:4 topping inside the chamber with a floating coat of 1.5mm thick neat cement laid in one operation to the topping, the entire inner surface of the chamber rendered with neat cement not less than 12mm in thickness of 1:2 cement sand plaster and finished with floating coat of neat cement 1 mm thick left absolutely smooth polished and correct to templates including labour for fixing the C.I. road gully grating and frame including painting with coal tar (as Specified in item No. Item 21.48) complete to the requirement of the Engineer in-charge 1.1. Single road gully chamber - Size: 610mm x 457mm x 800mm [Through Rate]
[22.103.3]Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 3. 25 mm nominal bore [Through Rate]
[22.106.1]Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 1. 15 mm nominal bore [Through Rate]
[22.108.1]Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1. 15mm nominal bore [Through Rate]
[22.15]Providing and fixing CP Brass 32mm size Bottle Trap of approved quality and make and as per the direction of Engineer-in-charge. [Through Rate]
[22.16]Providing and fixing 40mm i/d G.I. waste pipe embedded in walls up to floor level including cost of union and plumber joint [Through Rate]
[22.163.2]Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 2. 150 mm diameter [Through Rate]
[22.166.2.2]Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 2.2. 150 x 100 mm size P type With sewer bricks conforming to IS : 4885 [Through Rate]
[22.168.3]Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 3. 250 mm dia. R.C.C. pipe [Through Rate]
[22.174.1]Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 1. With common burnt clay non-modular bricks of class designation 7.5 [Through Rate]
[22.175.1]Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 1. With common burnt clay non-modular bricks of class designation 7.5 [Through Rate]
[22.190.2.1]Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (Zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 2.1. Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With common burnt clay non-modular bricks of class designation 7.5 [Through Rate]
[22.198.1]Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : 1. With 20x20 mm square bar [Through Rate]
[22.201.2.2]Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 2.2. M D - 10 Circular shape 500 mm internal diameter [Through Rate]
[22.209]Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. [Through Rate]
[22.216.1]Providing and fixing in position best Indian make (to the approval of the engineer-in-charge) storage type automatic electric water heater, pressure/non-pressure type thermostatically controlled, suitable for operation on 230 volts, 50 cycles single phase vertical wall mounting fitted with-draw able and adjustable type AC, thermostat. Thermostat knob to be readily accessible through the opening of suitable cover for and adjustment of temperature in the installed position of heater and the thermostat should be withdrawn without having to drain the water, electric heating element made out of copper tube (heating element should be easily removed and replaced in the installed position of heater) A neon indicator 1 AMP, inner container made out of copper tinned both from inside and outside, outer container made out of mild steel sheet finished in gleaming white stove enamel paint, insulated between the inner and outer with fibre glass wool with 1 metre length of suitable capacity 3 core flexible cord with plug and non return valve plastic/lead connections or pressure release valve (where required). Complete including fixing and testing for a week (as required by Engineer-in-charge. 1. 25 Litres capacity [Through Rate]
[22.22.1]Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1. White vitreous chinaware Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests [Through Rate]
[22.221.9]Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. 9. Size 560mm x 450mm (Under counter oval) [Through Rate]
[22.222.2.2]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.2. Single Socket Type B 110mm o/d SWR UPVC pipe lines laid complete [Through Rate]
[22.222.2.3]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.3. Single Socket Type B 90mm o/d SWR UPVC pipe lines laid complete [Through Rate]
[22.33]Providing and fixing white vitreous chinaware extended wall mounting water closet of size 780x370x690 mm of approved shape including providing and fixing white vitreous chinaware cistern / PVC cistern (with brass fitting) into the wall with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. [Through Rate]
[22.42.1]Providing and fixing toilet paper holder : 1. C.P. brass [Through Rate]
[22.46]Providing and fixing white vitreous chinaware battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre and post flushing with water (250 ml and 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. [Through Rate]
[22.82.1]Cutting holes up to 30x30 cm in walls including making good the same: 1. With common burnt clay non-modular bricks [Through Rate]
[22.88.3]Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 3. 25 mm dia nominal bore [Through Rate]
[22.89.1]Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : 1. 15 mm dia nominal bore [Through Rate]
[22.89.2]Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : 2. 20 mm dia nominal bore [Through Rate]
[22.9.1]Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required: 1. White glazed fire clay kitchen sink of size 600x450x 250 mm [Through Rate]
[22.90]Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. [Through Rate]
[22.91.1]Providing and fixing G.I. pipes complete with G.I. fittings including trenching up to 0.30m to 1.00m depth and refilling etc. External work 1. 15 mm dia nominal bore [Through Rate]
[22.91.2]Providing and fixing G.I. pipes complete with G.I. fittings including trenching up to 0.30m to 1.00m depth and refilling etc. External work 2. 20 mm dia nominal bore [Through Rate]
[22.91.4]Providing and fixing G.I. pipes complete with G.I. fittings including trenching up to 0.30m to 1.00m depth and refilling etc. External work 4. 32 mm dia nominal bore [Through Rate]
[22.91.5]Providing and fixing G.I. pipes complete with G.I. fittings including trenching up to 0.30m to 1.00m depth and refilling etc. External work 5. 40 mm dia nominal bore [Through Rate]
[22.92.1]Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 1. 25 to 40 mm nominal bore [Through Rate]
[22.92.2]Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 2. 50 to 80 mm nominal bore [Through Rate]
[22.94.1]Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 1. 15 mm nominal bore [Through Rate]
[22.94.2]Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 2. 20 mm nominal bore [Through Rate]
[22.94.3]Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 3. 25 mm nominal bore [Through Rate]
[22.94.4]Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 4. 32 mm nominal bore [Through Rate]
[22.94.6]Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 6. 50 mm nominal bore [Through Rate]
[22.98.1]Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 1. 25 mm nominal bore [Through Rate]
[22.98.2]Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 2. 20 mm nominal bore [Through Rate]
[22.98.3]Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 3. 32 mm nominal bore. [Through Rate]
[22.98.5]Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 5. 50 mm nominal bore [Through Rate]
[23.22.1.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA [Through Rate]
[23.22.3.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 3.2. Supply and erection of sheet steel enclosures 1pole/2 pole/4 pole on wall/on existing pedestal complete as required. S.P.N. or DP enclosure suitable for DP MCB [Through Rate]
[23.22.4.11]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.11. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door 8 way ( 8 incoming 3phase*8 outgoing) [Through Rate]
[23.22.4.12]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.12. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door 12 way ( 8 incoming 3phase*12 outgoing) [Through Rate]
[23.22.4.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.2. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 8 way ( 2 incoming and 6 outgoing) [Through Rate]
[23.22.4.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.5. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing) [Through Rate]
[23.22.4.7]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.7. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing) [Through Rate]
[23.22.4.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.8. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 12 way ( 8 incoming 3phase*12 outgoing) [Through Rate]
[23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate]
[23.22.5.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.3. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Double POLE [Through Rate]
[23.22.5.6]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.6. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs TRIPLE POLE [Through Rate]
[23.22.5.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE [Through Rate]
[23.22.7]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 7. Supply and erection of blanking sheet in existing distribution board. [Through Rate]
[23.23.1.2]MISCELLANEOUS 1.2. Supply and fixing Galvanised Iron flexible pipe complete with socket nipples and check nuts etc. at both ends (Up to length of one metre):- Size 20 mm dia [Through Rate]
[23.23.1.3]MISCELLANEOUS 1.3. Supply and fixing Galvanised Iron flexible pipe complete with socket nipples and check nuts etc. at both ends (Up to length of one metre):- Size 25 mm dia [Through Rate]
[23.23.5.1]MISCELLANEOUS 5.1. Supply and erection of U- PVC Trunking/Channel of following size including cost of fixing on wall, floor and ceiling etc. with required material complete the job in all respect up to entire satisfaction of the Engineer-in-charge of work. 25x12 mm [Through Rate]
[23.23.5.2]MISCELLANEOUS 5.2. Supply and erection of U- PVC Trunking/Channel of following size including cost of fixing on wall, floor and ceiling etc. with required material complete the job in all respect up to entire satisfaction of the Engineer-in-charge of work. 38x12 mm [Through Rate]
[23.23.6..2]MISCELLANEOUS 6..2. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 200 X 50 X 2 mm [Through Rate]
[23.23.6.1]MISCELLANEOUS 6.1. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 100 X 50 X 2 mm [Through Rate]
[23.23.6.3]MISCELLANEOUS 6.3. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 375 X 50 X 2 mm [Through Rate]
[23.23.6.4]MISCELLANEOUS 6.4. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 600 X 50 X 2 mm [Through Rate]
[23.23.8.1]MISCELLANEOUS 8.1. Supply and laying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and sealed in existing pipe/channel and making necessary connection complete in all respect up to the entire satisfaction of the Engineer-in charge of the work. 2 pair telephone wire [Through Rate]
[23.23.8.2]MISCELLANEOUS 8.2. Supply and laying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and sealed in existing pipe/channel and making necessary connection complete in all respect up to the entire satisfaction of the Engineer-in charge of the work. 4 pair telephone wire [Through Rate]
[23.23.9]MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required [Through Rate]
[23.26.1]SAFETY ITEMS 1. Supply and erection of Medium Voltage caution notice plate of size 200*150 mm in three languages. [Through Rate]
[23.26.2]SAFETY ITEMS 2. Supply and erection of High Tension Voltage caution notice plate of size 250*200 mm in three languages. [Through Rate]
[23.26.3]SAFETY ITEMS 3. Supply and erection of shock restoration chart in glass frame. [Through Rate]
[23.26.4]SAFETY ITEMS 4. Supply & Erection of mild steel bucket stand suitable for 6 Nos. fire buckets,(but without bucket) including the cost of welding and painting of complete stand will one coat of red oxide and 2 coats of approved paint of red colour with all labour and material required to complete the job in all respect up to the entire Satisfaction engineer in charge of the work (size 6x4 made of GI pipe 32mm dia). [Through Rate]
[23.4.1.3]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.3. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group C [Through Rate]
[23.4.3.1]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 3.1. Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe, without separate control switch Group A [Through Rate]
[23.4.4.3]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 4.3. Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group C [Through Rate]
[23.4.5.3]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 5.3. Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group C [Through Rate]
[23.5.6.10]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.10. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 3 run of Size 2.50 Sqmm(1.1.80mm) [Through Rate]
[23.5.6.3]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) [Through Rate]
[23.5.6.4]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.4. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 6 Sqmm(1/2.80mm) [Through Rate]
[23.5.6.5]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.5. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 10 Sqmm(1/3.50 mm) [Through Rate]
[23.5.6.9]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.9. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 3 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate]
[23.6.6.1]MS CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.1. Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. MS Pipe of 20 mm dia. [Through Rate]
[23.6.6.2]MS CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. MS pipe of 25 mm dia. [Through Rate]
[23.6.6.3]MS CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.3. Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work.c MS Pipe of 32 mm dia. [Through Rate]
[23.6.6.4]MS CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.4. Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. MS pipe of 40 mm dia. [Through Rate]
[23.7.6.1]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.1. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 20 mm dia. [Through Rate]
[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate]
[23.8.10.1]FITTING AND ACCESSORIES 10.1. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules including combined plate for Telephone and data [Through Rate]
[23.8.10.2]FITTING AND ACCESSORIES 10.2. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 3 Modules [Through Rate]
[23.8.11.1]FITTING AND ACCESSORIES 11.1. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch [Through Rate]
[23.8.11.10]FITTING AND ACCESSORIES 11.10. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Blanking plate [Through Rate]
[23.8.11.11]FITTING AND ACCESSORIES 11.11. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. RJ 45 Computer DATA socket outlet for CAT 6 or CAT6e cable Modular type [Through Rate]
[23.8.11.4]FITTING AND ACCESSORIES 11.4. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp Socket [Through Rate]
[23.8.11.7]FITTING AND ACCESSORIES 11.7. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 watt [Through Rate]
[23.8.11.8]FITTING AND ACCESSORIES 11.8. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Telephone Socket outlet modular type [Through Rate]
[23.8.11.9]FITTING AND ACCESSORIES 11.9. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. T.V. Socket outlet modular type [Through Rate]
[23.8.14]FITTING AND ACCESSORIES 14. Supplying,installation,testing and commissioning of Passive Infrared(PIR) based occupancy sensor with automatic day light dimming feature , programmable type, suitable for connected load up to 10Amp , for mounting height up to 2.8 metre and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required. [Through Rate]
[23.8.4]FITTING AND ACCESSORIES 4. Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job. [Through Rate]
[24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate]
[24.1.10]EARTHING AND LIGHTENING ARRESTOR 10. Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate]
[24.1.11]EARTHING AND LIGHTENING ARRESTOR 11. Providing and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required. [Through Rate]
[24.1.13]EARTHING AND LIGHTENING ARRESTOR 13. Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required. [Through Rate]
[24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. [Through Rate]
[24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. [Through Rate]
[24.1.4]EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required. [Through Rate]
[24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. [Through Rate]
[24.1.7]EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. [Through Rate]
[24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate]
[24.1.9]EARTHING AND LIGHTENING ARRESTOR 9. Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required. [Through Rate]
[24.11.18]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING AND ERECTION/LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITH SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES 18. 10 Sq mm 4 core (Arm.) [Through Rate]
[24.11.24]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING AND ERECTION/LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITH SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES 24. 16 Sq mm 4 core (Arm.) [Through Rate]
[24.11.32]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING AND ERECTION/LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITH SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES 32. 25 Sq mm 4 core (Arm.) [Through Rate]
[24.11.40]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING AND ERECTION/LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITH SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES 40. 35 Sq mm 4 core (Arm.) [Through Rate]
[24.11.46]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING AND ERECTION/LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITH SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES 46. 50 Sq mm 3.5core (Arm.) [Through Rate]
[24.11.54]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING AND ERECTION/LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITH SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES 54. 70 Sq mm 3.5 core (Arm.) [Through Rate]
[24.11.62]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING AND ERECTION/LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITH SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES 62. 95 Sq mm 3.5 core (Arm.) [Through Rate]
[24.11.70]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING AND ERECTION/LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITH SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES 70. 120 Sq mm 3.5 core (Arm.) [Through Rate]
[24.11.8]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING AND ERECTION/LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITH SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES 8. 6 Sq mm 2core (Arm.) [Through Rate]
[24.11.82]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING AND ERECTION/LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITH SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES 82. 185 Sq mm 3.5 core (Arm.) [Through Rate]
[24.11.88]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING AND ERECTION/LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITH SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES 88. 240 Sq mm 3.5 core (Arm.) [Through Rate]
[24.11.94]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING AND ERECTION/LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITH SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES 94. 300 Sq mm 3.5 core (Arm.) [Through Rate]
[24.12.94]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING AND ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITHOUT SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES 94. 300 Sq mm 3.5 core (Arm.) [Through Rate]
[24.13.12]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 12. 6 Sq mm 4 core (Arm.) [Through Rate]
[24.13.14]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 14. 10 Sq mm 2core (Arm.) [Through Rate]
[24.13.18]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 18. 10 Sq mm 4 core (Arm.) [Through Rate]
[24.13.24]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 24. 16 Sq mm 4 core (Arm.) [Through Rate]
[24.13.32]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 32. 25 Sq mm 4 core (Arm.) [Through Rate]
[24.13.40]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 40. 35 Sq mm 4 core (Arm.) [Through Rate]
[24.13.46]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 46. 50 Sq mm 3.5core (Arm.) [Through Rate]
[24.13.54]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 54. 70 Sq mm 3.5 core (Arm.) [Through Rate]
[24.13.62]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 62. 95 Sq mm 3.5 core (Arm.) [Through Rate]
[24.13.70]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 70. 120 Sq mm 3.5 core (Arm.) [Through Rate]
[24.13.8]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 8. 6 Sq mm 2core (Arm.) [Through Rate]
[24.13.82]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 82. 185 Sq mm 3.5 core (Arm.) [Through Rate]
[24.14.12]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 12. 6 Sq mm 4 core (Arm.) [Through Rate]
[24.14.14]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 14. 10 Sq mm 2core (Arm.) [Through Rate]
[24.14.18]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 18. 10 Sq mm 4 core (Arm.) [Through Rate]
[24.14.24]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 24. 16 Sq mm 4 core (Arm.) [Through Rate]
[24.14.32]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 32. 25 Sq mm 4 core (Arm.) [Through Rate]
[24.14.40]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 40. 35 Sq mm 4 core (Arm.) [Through Rate]
[24.14.46]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 46. 50 Sq mm 3.5core (Arm.) [Through Rate]
[24.14.54]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 54. 70 Sq mm 3.5 core (Arm.) [Through Rate]
[24.14.62]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 62. 95 Sq mm 3.5 core (Arm.) [Through Rate]
[24.14.70]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 70. 120 Sq mm 3.5 core (Arm.) [Through Rate]
[24.14.8]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 8. 6 Sq mm 2core (Arm.) [Through Rate]
[24.14.82]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 82. 185 Sq mm 3.5 core (Arm.) [Through Rate]
[24.14.88]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 88. 240 Sq mm 3.5 core (Arm.) [Through Rate]
[24.14.94]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 94. 300 Sq mm 3.5 core (Arm.) [Through Rate]
[24.15.4]HT CABLES (Aluminium Conductor, Armoured and Unarmoured) Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in 1 per meter below ground level with sand and bricks with all labour and material including digging and refilling of trench as required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 4. 95 Sq mm 3 core [Through Rate]
[24.2.10]LT CABLE 10. Supply and erection of cable route marker made of 50 cm long 10 mm dia M.S. Rod welded/riveted at the top with 10 cm dia 3 mm thick MS plate inscribed with cable word on it, having a cross arm 30 cm long of the same dia welded at the bottom, in exiting trench 45 cm below ground level. [Through Rate]
[24.2.7.1]LT CABLE 7.1. Supply and erection of suitable compression type brass cable glands for underground Cable :- Up to 6 Sq mm cable 2 to 4 Core [Through Rate]
[24.2.7.2]LT CABLE 7.2. Supply and erection of suitable compression type brass cable glands for underground Cable :- 10 sqmm to 16 sqmm Cable 2 to 4 Core [Through Rate]
[24.2.7.3]LT CABLE 7.3. Supply and erection of suitable compression type brass cable glands for underground Cable :- 25 sqmm to 50 sqmm Cable 2 to 4 Core [Through Rate]
[24.2.7.4]LT CABLE 7.4. Supply and erection of suitable compression type brass cable glands for underground Cable :- 70 sqmm to 95 sqmm Cable 3 to 3½ Core [Through Rate]
[24.2.7.5]LT CABLE 7.5. Supply and erection of suitable compression type brass cable glands for underground Cable :- 120 sqmm to 185 sqmm Cable 3 to 32 Core [Through Rate]
[24.2.7.6]LT CABLE 7.6. Supply and erection of suitable compression type brass cable glands for underground Cable :- 240 sqmm to Cable 3 to 32 Core [Through Rate]
[24.2.8.10]LT CABLE 8.10. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 120 sqmm [Through Rate]
[24.2.8.12]LT CABLE 8.12. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 185 sqmm [Through Rate]
[24.2.8.13]LT CABLE 8.13. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 240 sqmm [Through Rate]
[24.2.8.2]LT CABLE 8.2. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 4 sqmm to 6 sqmm [Through Rate]
[24.2.8.3]LT CABLE 8.3. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 10 sqmm [Through Rate]
[24.2.8.4]LT CABLE 8.4. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 16 sqmm [Through Rate]
[24.2.8.5]LT CABLE 8.5. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 25 sqmm [Through Rate]
[24.2.8.6]LT CABLE 8.6. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 35 sqmm [Through Rate]
[24.2.8.7]LT CABLE 8.7. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 50 sqmm [Through Rate]
[24.2.8.8]LT CABLE 8.8. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 70 sqmm [Through Rate]
[24.2.8.9]LT CABLE 8.9. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 95 sqmm [Through Rate]
[24.3.3.1]HT CABLE 3.1. Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :70 to 120 sqmm [Through Rate]
[24.3.4.1]HT CABLE 4.1. Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :70 to 120 sqmm [Through Rate]
[24.4.15.2]STREET LIGHT 15.2. B.S.E.N. 10025 High Masts "Supply, installation, testing and commissioning of 16 mtr. long High Mast manufactured from B.S.E.N. 10025 or equivalent grade material in, 2 (two) section hot dip, galvanized inside and outside in single dip, suitable for wind velocity as per IS 875 Part-3 suitable for 9/12 nos. luminaire loading fully motorized (power tool) with starter & cable complete along with standard accessories supplied by the manufacturer with 3 nos. steel wire rope double drum system and twin dome aviation light with LED without foundation but including cost of set of foundation nut and bolts, installation at site complete in all respect upto entire satisfaction of Engineer -in-Charge Thickness of Top and Bottom Section = 3 mm & 4mm (minimum) Top Dia = 150 mm and Bottom Dia = 410mm Thickness of Galvanization - Top = 65 micron (minimum) and Bottom = 85 micron (minimum)" [Through Rate]
[24.4.16]STREET LIGHT 16. Supply and erection of weather proof M.S. box of size 20 cm x 15 cm x 10 cm. covered with 3.00 mm thick M.S. sheet hinged cover, locking arrangement , housed in wall , including the cost of 1 no. 16 amp. 415 volts SP MCB and 2 nos. 63 amp. 415 volts neutral links fixed on hard wood board/10 mm Bakellite sheet in the M.S. box including painting and necessary connections . [Through Rate]
[24.4.2.2]STREET LIGHT 2.2. Supply and erection of GI bracket made of 32 mm dia medium class GI pipe, having 15 deg angle from horizontal, suitable for fixing on top of Street Light pole 90 cm long, with 20 cm high suitable size pole cap [Through Rate]
[24.4.8.3]STREET LIGHT 8.3. Supply and erection of Hot Dip Galvanized octagonal pole of 3mm thickness, with base plate including cost of nut and bolts , earthing studs, Integral Cable termination arrangement 5 mm thick Bakelite base plate on suitable welded MS/GI bracket 32 A four way connector 2 no 10 A SP MCB , end cover and all accessories as supplied by the manufacture including Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 5 Metre Long pole with top dia 65 mm and bottom dia 130mm with base plate of size 250 x 250 x 16 mm [Through Rate]
[24.4.8.4]STREET LIGHT 8.4. Supply and erection of Hot Dip Galvanized octagonal pole of 3mm thickness, with base plate including cost of nut and bolts , earthing studs, Integral Cable termination arrangement 5 mm thick Bakelite base plate on suitable welded MS/GI bracket 32 A four way connector 2 no 10 A SP MCB , end cover and all accessories as supplied by the manufacture including Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 6 Metre Long pole with top dia 75 mm and bottom dia 150 mm with base plate of size 275 x 275 x 16 mm [Through Rate]
[24.4.8.6]STREET LIGHT 8.6. Supply and erection of Hot Dip Galvanized octagonal pole of 3mm thickness, with base plate including cost of nut and bolts , earthing studs, Integral Cable termination arrangement 5 mm thick Bakelite base plate on suitable welded MS/GI bracket 32 A four way connector 2 no 10 A SP MCB , end cover and all accessories as supplied by the manufacture including Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 8 Metre Long pole with top dia 100 mm and bottom 200 mm with base plate of size 325 x 325 x 20 mm. [Through Rate]
[24.5.2.1]MISCELLANEOUS ITEMS 2.1. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 40/32 mm outer dia/ inner dia [Through Rate]
[24.5.2.2]MISCELLANEOUS ITEMS 2.2. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 50/40 mm outer dia/ inner dia [Through Rate]
[24.5.2.3]MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia [Through Rate]
[24.5.2.4]MISCELLANEOUS ITEMS 2.4. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 90/75 mm outer dia/inner dia [Through Rate]
[24.5.2.5]MISCELLANEOUS ITEMS 2.5. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 120/105 mm outer dia/ inner dia [Through Rate]
[24.5.2.6]MISCELLANEOUS ITEMS 2.6. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 145/123 mm outer dia/ inner dia [Through Rate]
[24.5.2.7]MISCELLANEOUS ITEMS 2.7. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 180/150 mm outer dia/ inner dia [Through Rate]
[24.7.5]RCC FOUNDATIONS FOR DG SET 5. 250 KVA DG Set [Through Rate]
[24.9.2]RCC FOUNDATIONS FOR HIGH MAST OCTAGONAL POLES 2. Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @ 75 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for high mast octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 16m high mast pole [Through Rate]
[28.11]`Supplying and installing 1.5 mm thick SBS membrane, self-adhesive polymer modified bitumen comprising of a cross laminated HDPE carrier film. Membrane shall come with a BBA certification giving a durability of membrane up to the life of the structure and shall have Tensile Strength : L: 215N/50mm T: 220N/50mm ( as per BS EN12311-1), Elongation : L: 324% and T: 238% (as per BS EN12311-1), Water Vapour Permeability : Impermeable to ISO 12572 (as per BS EN 1931), Resistance to Hydrostatic Head: Min 60m( as per ASTM D5385), Adhesion to primed concrete : 4.9mm (as per ASTM D1000). The surface shall be primed using Bituminous Primer and membrane shall be installed with an edge lap of 50 mm and end lap of 150 mm. Membrane Termination shall be done by providing a groove cut of 30mm x 30mm, put the membrane inside the groove, nailing of aluminium flashing at 200mm c/c and sealing with a suitable PU Sealant at the termination of waterproofing membrane at minimum of 300mm height on the vertical wall, as per the manufacturer’s Specification. Membrane shall be protected using 8mm thick dimple board for protection as per manufacturer`s recommendation followed by backfilling. The rates are inclusive of surface preparation, crack filling, injection grouting at honeycombed areas, coving, priming all complete as per manufacturer methodology but excluding for protection board. ` [Through Rate]
[28.16]Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken up to 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately). For the purpose of measurement the entire treated surface will be measured. [Through Rate]
[28.18]Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservoir, sewage and water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck , using integral crystalline admixture @0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer`s specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. [Through Rate]
[28.20.1]Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservoir, sewage and water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fibre brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. 1. For vertical surface two coats @ 0.70 kg per sqm [Through Rate]
[28.21]Providing and Applying polymer modified, flexible cementitious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @14.35 kg /10 sqm one coat of self priming of cementitious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementitious waterproofing polymer (dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film and loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge. [Through Rate]
[28.28.1]Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete : 1. Serrated with central bulb (225 mm wide, 8-11 mm thick) [Through Rate]
[28.29.1]Providing and applying crystalline mortar by mixing in the ratio of 4.5 : 1 (4.5 parts crystalline mortar : 1 part water) for the treatment of faulty construction joints, cracks, tie rod holes and spalled and honeycombed surface of RCC underground structures like basement, water tanks, bridge deck etc. to ensure water tightness. The crystalline mortar shall conform to the EN 1504-3 having compressive strength Class R4 =45 MPa and adhesive bond strength Class R3 =1.5 MPa. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge. The product performance shall carry guarantee for 10 years against any leakage. 1. For sealing cracks and faulty construction joints, routed out/making U-shape groove size 25x25mm and then primed the area with integral crystalline slurry @0.05kg/running metre and while the surface is tacky filled the groove up to surface with crystalline mortar @1.50kg/running metre. Once crystalline mortar is touch dry then finally applied two coats of integral crystalline slurry @0.05kg/running metre per coat. [Through Rate]
[29.7]Design supply and installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider and bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets and Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener and anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion and seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter and in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof and dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, TandP, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured. [Through Rate]
[30.17]Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge. [Through Rate]
[30.18]Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. [Through Rate]
[30.19]Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. [Through Rate]
[30.22]Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. [Through Rate]
[30.27.1]Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: 1. One or more coats on old work [Through Rate]
[30.35.1]Finishing walls with water proofing cement paint of required shade : 1. Old work (one or more coats applied @ 2.20 kg/10 sqm) over priming coat of primer applied @ 0.80 litres/10 sqm complete including cost of Priming coat. [Through Rate]
[30.37.1]Finishing walls with Acrylic Smooth exterior paint of required shade : 1. Old work (Two or more coat applied @ 1.67 litre/ 10 sqm) on existing cement paint surface [Through Rate]
[30.52.1]Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of malba/ debris/rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge. 1. For door/ window/ clerestory window [Through Rate]
[30.79]Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in-charge. [Through Rate]
[30.86]Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge. [Through Rate]
[30.88.1]Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 1. For pipes 100 to 250 mm diameter [Through Rate]
[31.1]Providing and fixing hard drawn steel wire fabric of size 75 x25 mm mesh or other suitable size wire mesh to be fixed and firmly anchored to the concrete surface by means of `L` shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool and plants as approved by Engineer-in-charge. [Through Rate]
[32.70.3]Supply Installation testing commissioning of Solar Photovoltaic grid connected roof top Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- (a) Solar Photovoltaic Module manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. (b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz plus /- 2.5 Hz, output voltage suitable to generate AC (c) Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degrees C. The PCU shall adjust the voltage and frequency level to suit grid frequency (d) Data Monitoring System complete with accessories. (e) Fixing of Array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. (f) Lightning and surge voltage protection. (g) Connections and Interconnections by supplying and fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying and fixing of necessary channel/conduit lugs and other accessories etc. as required. 3. Above 100 kWp and up to 500 Kwp [Through Rate]
[4.1]Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. [Labour Rate]
[4.1]Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. [Through Rate]
[4.12.1]Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil [Through Rate]
[4.14.1]Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1. All kinds of soil. [Through Rate]
[4.16.1.2]Excavating trenches of required width and depth for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. 1.2. All kind of soil Pipes, cables etc, exceeding 80 mm dia but not exceeding 300 mm dia. [Through Rate]
[4.17]Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth up to 1.5 metre). [Through Rate]
[4.22.1]Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete. (Measurements to be taken of the face area timbered). 1. Depth not exceeding 1.5 m [Through Rate]
[4.22.2]Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete. (Measurements to be taken of the face area timbered). 2. Depth exceeding 1.5 m but not exceeding 3 m [Through Rate]
[4.31.1]Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. 1. All kinds of soil [Through Rate]
[4.32]Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. [Through Rate]
[4.33]Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 1 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. [Through Rate]
[4.39]Providing and injection chemical emulsion for PRE-CONSTRUCTIONAL ant termite treatment (excluding the cost of chemical emulsion) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filing junction of wall and floor, along with the external perimetre of building, expansion joints surrounding of pipes and conduit etc, complete (plinth area of the building at ground floor only shall be measured) using Chlorpyriphos/ Lindane emulsifiable concentrate of 20% [Through Rate]
[4.40.5]Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : 5. Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same. [Through Rate]
[4.8.1]Earth work in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead up to 50 m and lift up to 1.5 m : 1. All kinds of soil [Through Rate]
[5.25]Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. [Through Rate]
[5.26]Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars. [Through Rate]
[5.29.1]Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1. Of area 3 sq. metres and below [Through Rate]
[5.29.2]Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 2. Of area beyond 3 sq. metres [Through Rate]
[5.30.1]Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 1. Of area 3 sq. metres and below [Through Rate]
[5.30.2]Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 2. Of area beyond 3 sq. metres [Through Rate]
[5.43.1]Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 1. For thickness of tiles 10 mm to 25 mm [Through Rate]
[5.43.2]Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 2. For thickness of tiles above 25 mm and up to 40 mm [Through Rate]
[5.45]Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. [Through Rate]
[5.7.4]Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 4. In cement mortar [Through Rate]
[6.1.2]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 2. 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) [Through Rate]
[6.1.6]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) [Through Rate]
[6.13]Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling and dressing and finishing the top smooth. [Through Rate]
[6.16]Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). [Through Rate]
[6.18]Reinforced cement concrete work in arches, arch ribs, domes, vaults, shells, folded plate and roofs having slope more than 15° up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). [Through Rate]
[6.25.1]Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. 1. All works up to plinth level [Through Rate]
[6.25.2]Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. 2. All works above plinth level up to floor IV level [Through Rate]
[6.29.1]Centering and shuttering including strutting, propping etc. and removal of form work for : 1. Foundations, footings, bases for columns [Through Rate]
[6.29.2]Centering and shuttering including strutting, propping etc. and removal of form work for : 2. Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. [Through Rate]
[6.29.3]Centering and shuttering including strutting, propping etc. and removal of form work for : 3. Columns, piers, abutments, pillars, posts and struts [Through Rate]
[6.30.19]Centering and shuttering including strutting, propping etc. and removal of form for 19. Weather shade, Chajjas, corbels etc., including edges [Through Rate]
[6.30.3]Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform [Through Rate]
[6.30.5]Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers [Through Rate]
[6.30.6]Centering and shuttering including strutting, propping etc. and removal of form for 6. Columns, Pillars, Piers, Abutments, Posts and Struts [Through Rate]
[6.30.7]Centering and shuttering including strutting, propping etc. and removal of form for 7. Stairs, (excluding landings) except spiral-staircases [Through Rate]
[6.33.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more [Through Rate]
[6.34.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more. [Through Rate]
[6.8.1]Providing and laying damp-proof course with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) 1. 50 mm thick [Through Rate]
[6.8.2]Providing and laying damp-proof course with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) 2. 40mm thick [Through Rate]
[6.8.3]Providing and laying damp-proof course with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) 3. 25 mm thick [Through Rate]
[7.22.1]Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 1. Cement mortar 1:4 (1 cement : 4 coarse sand) [Through Rate]
[7.22.3]Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 3. Cement mortar 1:3 (1 cement : 3 coarse sand) [Through Rate]
[7.74.2.1]Stone work plain ashlar in arches in super structure up to floor IV level in cement mortar 1:3 (1 cement : 3 coarse sand) including centering, shuttering and pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. 2.1. Both face dressed 0 0 Red sand stone 0 [Through Rate]
[7.83.1]Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with : 1. Cement mortar 1:6 (1 cement : 6 coarse sand) [Through Rate]
[8.26.2.1]Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 2.1. Granite of any colour and shade Area of slab up to 0.50 sqm [Through Rate]
[8.27.2]Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 2. Granite work [Through Rate]
[9.20]Providing and fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately). [Through Rate]
[9.21]Providing and laying on roof pressed clay tile ridge (Mangalore tile) of 20mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately). [Through Rate]
[9.29]Providing flat iron brackets 50x3 mm size with necessary bolts, nuts and washers etc. for fixing G.S. sheets gutters with purlins. [Through Rate]
[9.30]Supply, fabrication and installation of self-supported arch shaped galvalume/ Zincalume steel sheet roofing 1.00 MM thick (BMT) (only ± 0.2mm tolerance allowed) and 1.075 MM thick (total thickness)(only ± 0.2mm tolerance allowed) tensile strength 350 MPa coating mass 150 gm per sqm etc. of approved make . The manufacturer shall follow the IS codes 15961, type III with Super Durable Polyester paint, IS code 513, IS code 16163 and all other relevant Indian codes as per approved specification, design and drawings of the corporation. [Through Rate]
[9.46.1]Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts and bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering up to 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer`s specification and also including the cost of making openings for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 1. 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) [Through Rate]
[9.47.3]Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main `T` runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross `T` of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main `T` at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross `T` of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main `T` runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 3. 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit. [Through Rate]
[9.57.1]Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 1. 75 mm diameter [Through Rate]
[9.57.2]Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 2. 110 mm diameter [Through Rate]
[9.57.3]Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 3. 150 mm diameter [Through Rate]
[9.59.1]Providing and fixing Unplasticised -PVC pipe clips of approved design to Unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 1. 75 mm [Through Rate]
[9.59.2]Providing and fixing Unplasticised -PVC pipe clips of approved design to Unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 2. 110 mm [Through Rate]
[9.59.3]Providing and fixing Unplasticised -PVC pipe clips of approved design to Unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 3. 150 mm [Through Rate]
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.08 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.09 MB
BOQ_573351.xls
BOQ • 0.72 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .