Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.0 LAccepted-AOC 335 304 302 12 SUBHASPALLY SILIGURI | SILIGURI | DARJEELING | WEST BENGAL | 734001 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹12.1 L+₹13,518 (1.13%)Rejected-Finance RABINDRA NAGAR P O RABINDRA SARANI SILIGURI 734 006 DIST DARJEELING W B | JALPAIGURI | WEST BENGAL | 734006 | L2 | Rejected-Finance Highest | |
| 3 | L3₹12.2 L+₹17,464 (1.46%)Rejected-Finance 30 HAREN MUKHERJEE ROAD HAKIMPARA SILIGURI 734 001 DARIEELING WB | DARJEELING | WEST BENGAL | 734001 | L3 | Rejected-Finance Highest |
Tender Value
Refer Docs
EMD Value
₹24,000
Closing Date
25 Jan 2021, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer PWD Electrical
Superintending Engineer PWD North Bengal Electrical Circle P.W.D Inspection Bungalow Annex Building 1ST Floor Kutchery Road Venus More Siliguri
Electrical repairing works and new fittings at the Civil Defence Multi Disciplinary Centre Hatighisa
2021_WBPWD_313204_1
WBPWD/SENBEC/NIT-49/2020-2021
Open Tender
ELECTRICAL WORKS ORG
Item Rate
21 days
Civil Defence Multi Disciplinary Centre Hatighisa
Please refer Tender documents.
4 documents required · 4 mandatory
₹24,000
12 Feb 2021
6 Jan 2021
27 Jan 2021
6 Jan 2021
25 Jan 2021
11 Jan 2021
120 days
Amount
S&F dd HTPN MCBDB with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment [8 way] with incomer: 63A FP MCCB----01 no. & Outgoing: 6-32 Amps SPMCB 24nos.(Make- L&T / ABB / Siemens / Crabtree / Schnider)
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protect ion, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.[2+6 way] with incomer: 40A DP MCB 01no. & outgoing: 6-32Amps SPMCB 4nos. (Make- L&T / Siemens / Crabtree / Schnider / ABB)
S&L of following sizes XLPE/PVC, Al armoured cable on wall by saddling as per GS (KEI/POLYCAB/HAVELLS). 4CORE 16SQMM
2CORE 6SQMM
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of following size XLPE/PVC armoured cables. 4CORE 16SQMM
Finishing the end of following sizes XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials. 4CORE 16SQMM
Supplying and fixing PVC casing-capping [Precision Make] on wall or ceiling, incl. necy. PVC fittings etc. and mending good damages to building works 25x10mm Size
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 2x4 sqmm + 1x2.5 sqmm as ECC [TPN TO SPN & AC ]
2x2.5 sqmm + 1x1.5 sqmm as ECC [PP & Comp. Plug]
3x1.5 sqmm
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC asing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to light/fan/call bell point with piano key type switch (Anchor make) fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment and mending good damages to building works. [PVC casing-capping and Switch board both on surface] Average run 9 mtr
S&F 230V, 50Hz,18W 100lm/watt LED tube light only by 1no of semi skilled labour and 1 no of unskilled labour [Make: Crompton LGT8-20-865-2/IBLED /Havells]
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S &F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
S&F OLP 3+ AC starter 21Amps to be fixed in a 4 moduler switch board. [Make: Electron or equivalent]
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.
S&F 2P RCCB, 25Amps scc:10kA breaking cap., C curve, sensitivity: 100 milli Amps . [make:L&T/Legrand/ABB]
S&D of 230V,100W LED street light luminaries complete with all accessories as per choice of EIC, Fixing given below (Make: IB LED IORL06-100WH HSP / Crompton / Jaquar / Bajaj)
Fixing only Floodlight Fitting with suitable tie clamps and MS plate for mounting on Pole/Tower or similar structure.
S&D of 230V,100W LED flood light luminaries complete with all accessories as per choice of EIC, Fixing given above (Make: IB LED cosmic led / Crompton / Jaquar / Bajaj)
Providing CC (6:3:1) muffing 450x450x600 mm in size or equivalent size of cylindrical muffing above ground level around the pole base complete with 3 mm thick neatly finished cement plaster all round after dismantling the unserviceable muffing if any incl. fixing only loop box if necessary With 200x150x100mm 16 SWG GI Loop Box
Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double wash ers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. No. 8 SWG
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable& having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. incl. painting with anticorrosive paint
Servicing charges of 125kVA DG set after dismantalling the whole DG set and replacing the following items in place of damaged ones incl. S&F the item and reassembling the DG set as per directions of EIC incl testing the set ( FOR ONE NO. OF DG SET) 1. Fuel pump element ----------------------1 no. 2. Lube oil filter------------------------------1 no. 3. fuel filter-----------------------------------1 no. 4.Fuel separator-----------------------------1 no. 5.24V relay-----------------------------------1 no. 6.air filter-------------------------------------2 nos.
S&F of 12V 150AAH lead acid battery.[Make:EXIDE EXp8-XP 15000/FXPO XP 1500 or Equivalent ]
S&Fill coolant
S & F 2.5 Mfd Capacitor.
Supply & Fixing 240 V 6 A Piano key type switch (Brand approved by EIC) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/perspex cover and making necessary connec tions as required
Supply & Fixing 240 V 6 A socket (Brand approved by EIC) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as reqd
S&F 240V, 50Hz 200ltr. 4 Star Direct Cool Refrigerator [Make: WHIRLPOOL Vitamagic 200 L,/L.G/Samsung]
S&D 230V,50Hz, 9" sweep A.C. Exhaust Fan fixing mentioned below[Make: Havells VENTILAIR DB NEO/Usha/Orient]
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of 23 cm (9")
SITC of 2 ton split type Room A.C Machine Specs:- 1. Capacity:2 TR 2. Running Current:9.31 Amps 3. Standard cooling @ 100% capacity: 24700 BTU/hr. 4. Rated ISEER: 3.50 5 Energy consumpsion per annum: 1603 kWhr 6. Compressoe type: Hyper tropical rotary 7. Refrigerent type: R410A 8. Evaporator & Condencer Coil - Copper 9. Operating Temparature - 52℃ and above [Make: O GENERAL/ Zamil or Equivalent]
S&F 240V, 50Hz 200 ltr. Single Door deep freezer [Make:Blue Star CHF200 Single Door Deep Freezer (200 Ltrs, White) /Voltas/Godrej]
S&F 240V, 50Hz portable room heater (blower type) [Make:Bajaj Majesty RX11 2000 Watts Heat Convector Room Heater (Ivory)/Usha/Orpat]
S&F 240V, 50Hz 50"(126cm), Full HD, LED smart TV[Make: Sony W67G | LED | Full HD | High Dynamic Range (HDR) | Smart Tv or equivallent]
S/F of round header cap having 100mm dia incl. round header having radius of 1ft. For fixing 2 nos. of LED flood lights incl. painting with 2 coats of synthe tic enamel paint over a cost of R.O. primer as to GS.
Supply & Fixing Twin LED light fitting with 2X18W LED tube complete with all accessorie ssuspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connectedwith the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. [Make: CROMPTON IGP-162LT8-16 and LGT8-20-865-2 / HAVELLS / Jaquar / Bajaj]
M/S DAWN ELECTRICAL INDUSTRIES
ORIENT ENGINEERING WORKS
stage.html
html • 0.05 MB
technical_589812.pdf
PDF • 0.07 MB
techsummary_589812.pdf
PDF • 0.09 MB
finance_589812.pdf
PDF • 0.06 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_589812.pdf
PDF • 0.08 MB
AOC49.pdf
PDF • 0.20 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .