Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.1 LAccepted-AOC 6TH CROSS STREET KAMARAJ NAGAR PALAYAMKOTTAI | PALAYAMKOTTAI | TIRUNELVELI | TAMIL NADU | 627002 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹42.2 L+₹43,214 (1.03%)Rejected-AOC SHOP NO 48 HOSANNA LAXMI VENKETESWARA LAYOUT 2ND CROSS MARAGONDANAHALLI K R PURAM POST BANGALORE 560036 | BENGALURU URBAN | KARNATAKA | 560036 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹44.8 L+₹3.0 L (7.30%)Rejected-AOC 108 JAYARAM REDDY GARDEN DODDA BANSWADI BANGALORE 560 043 | BENGALURU URBAN | KARNATAKA | 560043 | L3 | Rejected-AOC NOT LOWEST |
| Sl No | Description | Qty | Unit | Janatha Trading Corporation L3 | M/S POTHIRAJ AND CO L1 | AURA ENTERPRISES L2 |
|---|---|---|---|---|---|---|
| 1.00 | Demolition of cement concrete (un-reinforced ) of any description & in any position not specifically provided for complete etc all as specified and as directed | 10 | Cum | 450 ₹4,500 | 600 ₹6,000 | 380 ₹3,800 Lowest |
| 2.00 | Taking down chowkats or frames with shutters (without taking off shutter from frames) area not exc. 1.5 sqm each including making good to match with adjoining surfaces etc, complete all as specified and as directed | 54 | Each | 150 ₹8,100 | 220 ₹11,880 | 108 ₹5,832 Lowest |
| 3.00 | Taking down chowkats or frames with shutters (without taking off shutter from frames) area exc. 1.5 Sqm but n exc 4.0 Sqm each including making good to match with adjoining surfaces etc complete all as specified and as directed | 34 | Each | 200 ₹6,800 | 240 ₹8,160 | 118 ₹4,012 Lowest |
| 4.00 | Taking down shutter of any description area exc 1.00 Sqm but not exc 2.00 sqm each etc complete all as specified and as directed | 16 | Per Leaf | 50 ₹800 Lowest | 150 ₹2,400 | 88 ₹1,408 |
| 5.00 | Taking down cement plaster of any description hacking for key or raking out joint on old brick work / stone / concrete surface etc complete all as specified and as directed | 262 | Sqm | 80 ₹20,960 | 40 ₹10,480 | 18 ₹4,716 Lowest |
| 6.00 | Taking down shutter from frames of any description area exc 1.00 sqm & not exc 2.00 sqm each and refixng in same opening after easing / minor adjustment / repairs / side cutting / repairs etc complete all as specified and as directed
Notes : Glass, wire cloth, butt hinges, Handle, tower bolt, sliding door bolt or any other mtrl reqd to fixing the door shutter, shall be measured and paid Sepeartely | 12 | Per Leaf | 125 ₹1,500 Lowest | 240 ₹2,880 | 166 ₹1,992 |
| 7.00 | Taking down Handle / Sliding door bolt/ Hasp & Staple/ Tower Bolt / piano hinges etc of any size and any description etc complete all as specified and as directed | 20 | Each | 10 ₹200 Lowest | 20 ₹400 | 44 ₹880 |
| 8.00 | M&L for Plain cement concrete (1:4:8) type D- 2 using 40mm graded stone aggregate as in 75 mm thick sub base to flooing etc complete all as specified and as directed | 25 | Sqm | 240 ₹6,000 Lowest | 290 ₹7,250 | 480 ₹12,000 |
| 9.00 | M&L for cement concrete (1:2:4) type B-0 using 12.5 mm graded stone aggregates as in 25 mm thick sub base to flooring etc complete all as specified and as directed | 150 | Sqm | 180 ₹27,000 | 160 ₹24,000 Lowest | 238 ₹35,700 |
| 10.00 | M&L for PCC (1:3:6) type C-1 using 20 mm graded stone aggregates as in 75 mm thick plinth protection finished even and smooth without using extra cement including joints filling with sealing compound Grade "A" complete all as specified and directed. | 60 | Sqm | 320 ₹19,200 Lowest | 340 ₹20,400 | 538 ₹32,280 |
Tender Value
₹45.5 L
EMD Value
₹91,000
Closing Date
29 Dec 2025, 6:00 pmClosed
CWE (ARMY) BANGALORE
CWE (ARMY) BANGALORE, 101, DICKENSON ROAD, BANGALORE - 560042
SPECIAL REPAIRS TO BLDG NO P-07 (TOTAL 08 QTRS) AT RC LINES, PROVN OF FENCING AT HQ NTG /NLC (HAL) AND CLOTH DRYER IN POC AND TOC UNDER GE (NORTH) BENGALURU
2025_MES_743542_1
86475/E8
Open Tender
Civil Works
Item Rate
180 days
CWE (ARMY) BANGALORE
AS PER TENDER
8 documents required · 8 mandatory
₹500
GE (NORTH) BANGALORE
₹91,000
31 Mar 2026
8 Dec 2025
5 Jan 2026
8 Dec 2025
29 Dec 2025
22 Dec 2025
8 Dec 2025 - 15 Dec 2025
Taking down cement plaster of any description hacking for key or raking out joint on old brick work / stone / concrete surface etc complete all as specified and as directed
M&L for cement concrete (1:2:4) type B-0 using 12.5 mm graded stone aggregates as in 25 mm thick sub base to flooring etc complete all as specified and as directed
M & L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including screed bed 15 mm thick cement mortar (1:6) including dismantling floor, hearth or wall tiling etc complete all as specified and as directed
M&L for Glazed ceramic coloured tiles of size 300X450X7mm thick as in skirting / dado, set and jointed in neat cement slurry and pointed in white or colour cement to match over & including backing coat 10 mm thick cement mortar (1:3) including dismantling floor, hearth or wall tiling etc complete all as specified and as directed
M&L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia, or securing with clips etc complete all as specified and as directed
M&L for rendering 10 mm thick cement mortar (1:6) on fair faces of brick work or concrete surface finsihed even and smooth without using extra cement etc complete all as specified and as directed
(ii) Second layer of slurry of cement @ 0.242 kg/sqm mixed with with Acrylic based polymer modified cementitious composite compound @ 0.126 kg/sqm. The layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (iii) 20mm thick screed in cement mortar 1:3 mixed with liquid water proofing compound. (iv) Provide 40mm dia light grade GI spout at the lowest point with 30cm projection beyond the out face of the wall. (v) Cement concrete 1:5:10 type E-2 using 20mm granded brick aggregates as in sunken portion of WC. (Note : Treatment shall be tested for water ponding for 7days)
M&L for water proofing treatment for RCC roof slab as per following specification complete all as specified and directed :- (a) Removing all loose gravel, dirt, oil, grease and foreign materials by jet or dry air, cleaning the surfaces mechanically or by grinding to make it smooth (b) Screed bed 10 mm thick cement mortar (1:3) mixed with water proofing compound finished to even & smooth (c) Applying compatible primer @ 0.40 Litr/Sqm
(d) Laying APP modified water proofing membrane as per IS 1654-2017/IS 16352-2017, 3mm thick and weighing not less than 3.80kg/Sqm reinforced with non woven polyster/HMHDPE matt black finished over and torch applications of membrane with 100mm side overlap and 150mm end lap after necessary preparation of surface complete as per manufacturer's instructions (e) Applying a coat of aluminum paint on top @ 0.10 litre/sqm (Note : WPC will be measured & paid seperately)
M&L for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290-0 or Fe -E-165 etc complete all as specified and as directed
cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete as sepecified and directed (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life)
S&F Aluminium anodised tower bolt 200 mm long of extruded section etc complete all as specified and as directed
S&F Butt hinges 100 mm size medium weight, stainless steel and fixed with screws etc complete all as specified and as directed
S&F in repairs Towel ring, Stainless steel glossy finish complete all as specified and directed (Make : Prayag cat No BA-02 or equivalent make as specified in P S )
S&F PVC vent cowls suitable for 110mm dia pipe etc complete all as specified and as directed
S&F PVC (SWR) branch pieces 75 mm dia bore, single (single Y) equal or unequal etc complete all as specified and as directed
M & L for sand cushioning with a layer of river sand under and above the cable all as per Para 19.75 of SSR Part-I complete all as specified and as directed
Supply & laying sub class 'B' burnt bricks for cable protection complete as specified as directed
M&L for Preparation of wall surface with sand paper etc., and applying 1mm thick wall care putty finished to smooth surface etc complete all as specified and as directed
M&L for Preparation of new or previously un-treated steel and iron surfaces of any description, over 10 cm in width or girth , not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and as directed
M & L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter finished fair flat surfaces all as specified and as directed
M & L for RCC (1:2:4) type B-1 using 20mm grded stone aggregate in walls or retaining walls, any thickness, size or shape ncluding pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) all as specified and as directed
M & L for Mild steel work in fencing posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 all as specified and as directed
M & L for Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) all as specified and as directed
M & L for Galvanised punched tape 3mm thick concertina coil 600mm dia fixed over angle iron Y type section all as specified and as directed
S&F in repairs Health faucet, brass body with 1mtr S S braided tube & wall hook complete all as specified and as directed (Make : Prayag cat No. BEA-41 or equivalent make as specified in P S)
Removing building materials etc. (other than soil) to a distance of exc 100 mtr but not exc 1.00 Km , including loading, unloading and stacking at the destination etc complete all as specified and as directed
Taking down carefully aluminium/ copper wiring/power point wiring (light, fan, socket or power) complete including fittings such as switches ceiling roses, regulators, sockets light fittings, fans etc and making good the disturbed surface of walls, ceiling etc incl painting with same colour of the back ground complete all as specified and as directed
M & L for surface Point Wiring with single core PVC insulated unsheathed FRLS cable 1.5 Sqmm 1100 volts grade multi stranded copper conductor conforming to IS 694 drawn through and including non-metalic rigid PVC conduit with accessories surface run on walls/ ceiling with MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly for the followings all as specified and as directed :-
One light / fan point controlled by one switch
One light point controlled by two way switch
One 3 pin socket out let 5 Amps on independent board
One 3 pin socket out let 5 A on same board
M&L for Preparation finished wall suface and applying two coats Distemper acrylic emulsion, white or tinted over a coat of primer etc complete all as specified and as directed
One Bell / Buzzer Point controlled by bell push
M & L for Surface point Wiring with single core PVC insulated unsheathed FRLS cable 2.5 Sqmm 1100 volts grade multi stranded with copper conductor conforming to IS 694 drawn through and including non-metalic rigid PVC conduit with accessories surface type run on walls/ ceiling including MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
S&F in repairs LED batten with luminaire suitable for indoor applications 20 Watts, 4 feet long with extruded aluminium housing & integrated LED channel complete with all accessories including taking out old fittings all as specified and directed.
S&F in repairs LED batten with luminaire suitable for indoor applications 10 Watts, 2 feet long with Polycarbonate integrated LED channel complete with all accessories including taking out old fittings all as specified and directed.
S&F in repairs Decorative, wall mounting ,champagne gold finish fixture with plastic body suitable for 9 watt LED lamp B22 base all as specified and directed.
S&F Switch piano flush type single pole one way 5amps, 230 volts all as specified and directed.
S&F Switch piano flush type single pole two way 5amps, all as specified and directed.
S&F Ding Dong bell AC 230 volts single pole all as specified and directed.
S&F Bell push flush type 5Amps 230volts all as specified and as directed .
S&F Stepped type electronic fan regulator, flush Switch/socket type, 230volts all as specified and as directed
S&F Switch socket combination 2 in 1 , 5 Amps flush type, 230volts all as specified and as directed
S&F Switch socket combination 2 in 1, 3 pin 5 and 15 Amps flush type universal type 230volts all as specified and as directed
S&F in repairs MCB SPN 240 volts, 32/40 Amps C curves complete all as specified and as directed
S&F in repairs MCB single pole 240 volts, 10/16/20/32 Amps, C curves complete all as specified and as directed
S&F in repairs MCB Distribution board, SPN 12 way, double door type, 240 volts with 200 Amps rated busbar all as specified and as directed.
S&F Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. complete all as specified and directed.
S&F in repairs MCB Distribution board, TPN 4 way double door type, 240 volts with 200 Amps rated busbar all as specified and as directed.
S&F in repairs MCB TPN, 63 Amps capacity 415 volts, 10 KA, 'C' curves complete all as specified and as directed
S&F Ceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals all as specified and as directed
S & F in repairs Sub main wiring with two runs single core 6 Sqmm 1100 volts grade multistranded FRLS copper conductors with PVC insulated single core multistranded copper conductor 6 Sqmm cable as earth continuity conductor with & including suitable size PVC casing caping all as specified and as directed
M&L for earthing with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick bu
ried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I and as specified or indicated and testing on completion including earth work and excavation in any type of soil, PCC (1:3:6) type C1 chamber, pre cast slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia TMT bars reinforced at 10 cm centre to centre both ways, funnel with watering G I pipe wire mesh and lugs, test point including dismantling old un-serviceable earthing complete all as specified and as directed
Supply and fixing in repairs LED bldg security light fitting 30 Watts capacity with pressure die cast housing along with prismatic polycarbonate diffuser with IP 66 protection all as specified & directed.
S&F in repairs GI Bracket made out of GI tubing medium grade 25 mm bore, approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm, nuts, bolts, washers etc and including applying two coats of aluminum paint over a coat of red oxide primer complete all as specified and directed.
Supply and fix Exhaust fan 300mm sweep, steel body AC single Phase. 230Volts with, blades, frame and louvers including necessary core cutting arrangement for installation all as specified and directed
M & L for removing excavated soil to a distance not exc 1.5 mtr above the starting point complete all as specified and as directed
S&F fix exhaust fan 225mm sweep, steel body AC single phase. 230Volts with, blades, and frame and louvers complete including necessary core cutting arrangement for installation all as specified and directed
Excavation in trenches in hard/dense soil not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of cables/errection of pole etc complete all as specified and as directed.
M & L for returning, filling in trenches including spreading levelling watering and well ramming in layers with soil not exc 25 cm thick in each layer complete as specified and as directed
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
BOQ_832567.xls
BOQ • 1.29 MB
tender86475.pdf
Tender Documents • 1.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .