| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.0 LAccepted-AOC E 140 2010 BKP VILL AMTALLA PO DUMARCHIR DIST PAKUR PIN 814111 JHARKHAND | PAKUR | PAKUR | JHARKHAND | 814111 | L1 | Accepted-AOC REASONABLE | |
| 2 | L2₹10.0 L+₹70,575 (7.57%)Rejected-Finance | L2 | Rejected-Finance HIGH RATE | |
| 3 | L3₹10.5 L+₹1.2 L (13.0%)Rejected-Finance | L3 | Rejected-Finance HIGH RATE | |
| 4 | L4₹10.8 L+₹1.5 L (16.0%)Rejected-Finance | L4 | Rejected-Finance HIGH RATE | |
| 5 | L5₹11.2 L+₹1.8 L (19.6%)Rejected-Finance | L5 | Rejected-Finance HIGH RATE |
Tender Value
₹9.4 L
EMD Value
₹19,000
Closing Date
16 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I AF SINGARSI
AGE I AF SINGARSI
Repair Maintenance of DG Sets of different capacities at AF Stn Singarsi under AGE I AF Singarsi
2020_MES_355516_1
C/8479/E8
Open Tender
Civil Works
Item Rate
180 days
AGE I AF SINGARSI
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Yes
AGE I AF SINGARSI
₹19,000
Yes
26 Aug 2020
24 Jun 2020
18 Jul 2020
24 Jun 2020
16 Jul 2020
27 Jun 2020
30 days
Amount
Comprehensive maintenance including periodical servicing & reguler inspection of 400 KVA DG Set (Make : KOEL, Location : Sub Stn -05) by the authorised technician / service engineer of OEM or their authorised service dealer, checking the mechanical and electrical healthyness of the diesel engine and alternator, routine servicing of the DG set including cleaning & replacement of air filter, changing of fuel filter and lubracating oil filter,draining out unserviceable engine oil from engine and refill with new engine oil, cleaning all sludge/deposits in the oil sump and removed off the site as per schedule, minor adjustment of control parameters, tracing out the defects and replacement of defective spares including taking out the old unserviceable one to keep the DG set healthy and serviceable state as specified and directed by Engr-in-charge at site. (Notes :- (a) Spares , engine oil will be measured and paid separastely as applicable. (b) The DG set to be inspected and maintained at least one in a month on regular interval as prescribed by the OEM and additional attendance for maintenances on as required basis are to be carried out. Maintenance of DG Sets are to be planned and carried out in a staggered manner so that more than one DG Set of any one installation is not brought under maintenance at a time. (c) In case, any abnormality found in between normal routine inspections, the service personnels must attend the service call urgently within 24 hrs. (d)Apart from these routine servicings, major repair/replacement if any as decided by Engr-in-Charge will be measured and paid separately available within the scope of this schedule. (e) A Log Book indicating the details of all types of repairs and maintenance carried out time to time has to be recorded by the contractor's rep/supervisor and endorsed by contractor , JE(E/M) and AGE(E/M)/Engr-in-Charge regularly. The contractor's rep/supervisor will monitor the serviceability of all the DG Sets daily and give report to AGE(E/M). This register is required to be produced at the time of claiming payment.
All as per item No 01 here-in-before but capacity 160 KVA DG Set (Make : KOEL, Location : Booster Pump House)
All as per item No 01 here-in-before but capacity 62.5 KVA DG Set (Make : KOEL, Location : Pump House No-04)
All as per item No 01 here-in-before but capacity 30 KVA DG Set (Make : Ashok Leylend, Location : SAG Pakur)
All as per item No 01 here-in-before but capacity 10 KVA DG Set (Make : Kirloskar, Location : Logestic Section)
Taking down the radiator of 400 KVA DG Sets from engine, transportation to the workshop, dismantling the radiator, repairing of top and bottom tank including necessary welding / brazing & making the radiator leak proof, cleaning the complete radiator internally with chemical agent (K Clean) and outside with Kerosene oil and high pressure water jet,filling of coolant including replacement of defective copper core, suction connection, main pipe, stud, stay, spacer, rubber hose (02 Nos) and assembling the radiator including replacement of all old rusted mild steel nuts, bolts washers & gasket sets and hose pipe asembly including transportation from wksp to original work site & fixing to the engine and testing complete.(Coolant for radiator will be measurd and paid separately)
All as per item No 6 here-in-before but capacity 160 KVA DG Set
All as per item No 6 here-in-before but capacity 62.5 KVA / 30/ 10 KVA DG Set
Taking proper shut down and disconnecting HT/LT connections from control panels and DG set of capacity 160 KVA (located at Booster pump house) and disconnecting / removing of earthing strips, UG cables & Nut Bolt etc from DG set etc complete and lifting up of the Complete DG set and control panel by Suitable capacity of crane, Putting on a Suitable Truck and Transporting from Booster Pump House carefully, (appx 06 KM distance on hilly area to Power House SS No- 5) and putting down the DG set from Truck, Reassembling/Re installing the DG set and control panel on PCC plate form at Booster Pump House by help of crane and connecting the HT/LT cable, Earthing strip, Nut bolt etc complete including testing and commissioning up to the entire satisfaction of Eng-in-charge
Taking proper shut down and disconnecting HT/LT connections from control panels and DG set of capacity 320 KVA (located at SS No-5) and disconnecting / removing of earthing strips, UG cables & Nut Bolt etc from DG set etc complete and lifting up of the Complete DG set and control panel by Suitable capacity of crane, Putting on a Suitable Truck and Transporting to Booster Pump House carefully, (appx 06 KM distance on hilly area from Power House SS No- 5) and putting down the DG set from Truck, Reassembling/Re installing the DG set and control panel on PCC plate form at Booster Pump House by help of crane and connecting the HT/LT cable, Earthing strip, Nut bolt etc complete including testing and commissioning up to the entire satisfaction of Eng-in-charge
Taking out self starter 24 volt from the 400KVA / 160 KVA DG Set, transportation to workshop opening/disconnecting all internal connection, cleaning the same taking out burnt coil, segrigation of serviceable parts for re-use, rewinding of coil with existing size of copper wire. Reassembling the same with replacement of of carbon brush 01 set, Beadix pinion 01 no, Half clutch assy 01 No, Field coil 01 No, solonoid switch 01 No., commutator 01 nos, fixing the self starter on the engine at site and testing complete all as directed by Engr-in-Charge.
Taking out self starter 12 volt from the 62.5 KVA / 30 KVA DG Set, transportation to workshop opening/disconnecting all internal connection, cleaning the same taking out burnt coil, segrigation of serviceable parts for re-use, rewinding of coil with existing size of copper wire. Reassembling the same with replacement of of carbon brush 01 set, Beadix pinion 01 no, Half clutch assy 01 No, Field coil 01 No, solonoid switch 01 No., commutator 01 nos, fixing the self starter on the engine at site and testing complete all as directed by Engr-in-Charge.
Taking out turbocharger from the 400 KVA DG Set, transportation to work shop for repair and dismantling the same, cleaning and carrying out thorough inspection of each components/spares segrigation of u/s & serviceable spares for reuse and decarbonising machine, cutting, grinding polishing etc and re-assembling of the turbocharger by replacement of turbocharger shaft, turbocharger kit and connected spare parts to match with the existing , refixing and testing as directed at site by Engineer in Charge.
All as per item No 13 here-in-before but capacity 160 KVA DG Set
All as per item No 13 here-in-before but capacity 62.5 KVA DG Set
Taking out alternator assembly of 400/160 KVA DG set from prime mover by unscrewing, foundation & coupler bolts/nuts and transportation to workshop for necessary repair, maintenance as follows :- (a) Dismantling of complete alternator assembling, taking out exitor unit, rectifier, armature assembly including shaft, bearing, slip ring etc and keeping aside for further repair/maintenance.(b) Removing of dust from field coils, armature, exitor unit by means of blowing forced air using blower and cleaning of all components using carbon tetra chloride all as directed and segregation of unserviceable and serviceable spares/components for necessary replacement and re-use respectively.(c) Varnishing of armature, exitor unit, field coil assembly using Ist quality doctor beak insulation varnish and retain in heat chamber for 48 hours for complete drying including replacement of novex/vertex paper in place of worn out one in exitor / field unit all as required. (d) Assembling of complete alternator assembly including replacement of bearings, rectifier diodes & other accessories and components including requisite lubrication with grease in all moving parts like bearing etc. (e) Carrying insulation test of field coil to body, armature to body to achieve the healthy insulation level. (f) Transportation of repaired and assembled alternator to main power house and coupling with prime mover including bolting with foundation from and realignment with prime mover complete to the entire sastisfaction of Engr-in-charge and commissioning and driving with full load all as directed. (g) Testing the DG set on "ON / OFF Load", matching to the existing range of RPM of the engine to the sastisfaction of Engr-in-Charge.
All as per item No 14 here-in-before but capacity 62.5 KVA / 30 KVA/10 KVA DG Set
Dismantling of unserviceable winding materials and material labour for rewinding of alternator coils / field coils with superenamelled copper wire and other protective materials and spares of appropriate gauge / size / quality to match with the existing design and standards for alternators of any type / make and capacity and all as directed and as approved by Engg-in-charge. (This item will be measured seperately as actual in connection to item No 15 and16 above if required at site)
Supply only Turbo compressor out pipe (LH view from FWE ), Make : KOEL, Cat No : DV8.033.34.0.00
Supply only Turbo compressor out pipe (RH view from FWE) ,Make : KOEL, Cat No :DV8.033.35.0.00
Supply only "O" ring for turbo outlet,Make : KOEL, Cat No. F6.377.06.0.00,
Supply only "V" bend clamp,Make : KOEL, Cat No :F6.377.04.0.00
Supply only Jupiter T-Bolt clamp S/F 83 mm O.D. ,Make : KOEL,Cat No :F6.377.16.0.00
Supply only lubricating oil pressure sender VDO,Make : KOEL, Cat No :2H.092.11.0.00
Supply only Preline filter (without water level sensor), MICO F 002H22026 ,Make : KOEL, Cat No :DVO.053.04.0.00
Supply only Schwitzer Turbocharger (S 200/80H27BECRM/74DA7-0.85A/R-VTE), Make : KOEL,Cat No :DVO.032.17.0.00
Supply only Flange for turbocharger oil drain,Make : KOEL, Cat No :DVO.032.08.0.00
Supply only Belt 'V' section (Bx58 pitch length 1520),Make : KOEL, Cat No :DVO.016.08.0.00
Supply only Belt 'V' section (Ax56),Make : KOEL,
Supply only Fuel filter assembly (Consisting of fuel filter & mounting bracket), Make : KOEL, Cat No :DV0.020.01.0.00
Supply only Engine Oil, 15W 40, Make : Castrol/Speed/HP/Shell/Viscol/Veedol.
Supply only Engine Oil, 20W 40 Make : Castrol/Speed/HP/Shell/Viscol/Veedol.
Supply only Coolant for radiator for 400/160/62.5/30/10 KVA of Model: KOEL Make : KOEL CARE (K-COOL) or equvavelent Castrol/Speed/HP/Shell/Anand/ Chemtex/Viscol/Veedol.
Supply only Coolant for radiator for 400 KVA . Model :Greavs Cotten GREAVESKOOL or equvavelent Castrol/Speed/HP/Shell/l/Veedol.
Supply only Air Cleaner Primary element for 160 KVA DG set, Make : KOEL, Cat No-6H.411.02.0.00
Supply only Air Cleaner Safety element for 160 KVA DG Set, Make : KOEL, Cat No-6H.411.01.0.00
Supply only Fuel filter pre for 160 KVA DG set, Make : KOEL, Cat No-48.117.04.0.00
Supply only Fuel filter micro for 160 KVA DG set, Make : KOEL, Cat No-48.117.05.0.00
Supply only spin on filter for lubricating oil for 160 KVA DG set, Make : KOEL, Cat No-06.436.01.0.00
Supply only Air filter cleaner primary element for 400 KVA DG set, Make : KOEL, Cat No-KV0.505.02.0.00
Supply only Air filter cleaner safety element for 400 KVA DG set, Make : KOEL, Cat No-KV0.505.03.0.00
Supply only lubricating Oil filter element for 400 KVA DG set, Make : KOEL, Cat No-DV0-014.11.0.00
Supply only Fuel filter and cartridge for 400 KVA DG set, Make : KOEL, Cat No DV0.020.03.0.00
Supply only Preline filter cartridge for 400 KVA DG set, Make : KOEL, Cat No-DV0.053.05.0.00
Supply only AVR suitable for Kirloskar Alternator Model -TAVR3A, Cat No: F6.814.11.0.00
Supply only AVR suitable for Kirloskar Alternator Model - TAVR10/14/20, Cat No: 2H.811.32.0.00
Supply only AVR suitable for 10 KVA DG Kirloskar Alternator
Supply only Battery 12 volts 180 AH heavy duty suitable for DG Set operation. Make: Exide or equivalent as approved.
Supply only 'V' Belt suitable for 400 KVA DG Set same as per existing
Supply only 'V' Belt suitable for 160 / 62.5 / 30 /10 KVA DG Set same as per existing
Supply only Thermostat element for 400 KVA DG Set, Make : KOEL, Cat No: DV0.015.01.0.00
Supply only assemble of Stop solenoid for 160 KVA DG set, Make : KOEL, Cat No-F6.561.20.0.00
Supply only assemble of Stop solenoid for 10 KVA DG set, Make : KOEL,
Supply only Relay board for 160 KVA DG set, Make : KOEL, Cat No-F6.863.17.0.00
Supply only Engine mechanical system (EMS) 907 for 160 KVA DG set, Make : KOEL, Cat No-2H.865.51.0.00
Supply only Thermostat element for 160 KVA DG set for Kirloskar Green, Make : ISI marked.
Supply only Self Starter motor for 62.5 KVA DG Set, Make : L&T/Legrand/ Havells/ABB/Siemens.
Supply only Engine Control Panel with EMS unit for 62.5 KVA Kirloskar Green DG Set.
Supply only lubricating oil pressure (LOP) Sender for 160 KVA DG set, Make : KOEL, Cat No-2H.092.11.0.00
Supply only Fuel Filter element set for 30 KVA Ashok Layland DG Set.
Supply only Lub Oil Filter element set for 30 KVA Ashok Layland DG Set.
Supply only Air Cleaner element set for 30 KVA Ashok Layland DG Set.
Supply only Exhaust Silencer for 62.5 KVA DG Set complete with flange, exhaust pipe and fixing accessories
Supply only Fuel pipe for 400 KVA DG set as per sample.
Supply only Fuel pipe for 160 KVA DG set as per sample.
Supply only Fuel pipe for 62.5 /30 KVA DG set as per sample.
Supply only Rubber coupling for 400 KVA DG set as per sample.
Supply only Rubber coupling for 160 KVA DG set as per sample.
Supply only Rubber coupling for 62.50 /30/10 KVA DG set as per sample.
Supply only Air filter for 10 KVA DG set as per sample.
Supply only Lubricating Oil filter for 10 KVA DG set as per sample.
Supply only by pass hose for 10 KVA DG set as per sample.
Supply only head gasket for 10 KVA DG set as per sample.
Supply only racker box joint for 10 KVA DG set as per sample.
Supply only racker cover joint for 10 KVA DG set as per sample.
Supply only fuel pipe 3 ft long for 10 KVA DG set as per sample.
Supply only L L OP Sinsor for 10 KVA DG set as per sample.
Supply only Hose L type for 10 KVA DG set as per sample.
Supply only wiring harness for 10 KVA DG set as per sample.
Supply only door hinges suitable for 400/160/62.5/ 10 KVA DG set as per sample.
Supply only door locks suitable for 400/160/62.5/ 10 KVA DG set as per sample.
Supply only safety pannel complete for 10 KVA DG set as per sample.
Supply only indicator light for 400/160/62.50 /30/10 KVA DG set as per sample.(Make:L&T/Siemens/GE)
Supply only Ammeter 4" for 400/160/62.50 /30/10 KVA DG set as per sample.(Make:L&T/Havells/AE)
Supply only Voltmeter for 400/160/62.50 /30/10 KVA DG set as per sample.(Make:L&T/Havells/AE)
Supply only Radiator cap for 400/160/62.50 /30/10 KVA DG set as per sample.(Make:L&T/Havells/AE)
M&L for applying two coats of synthetic enamel spray painting to diffirent capacity DG Sets of existing colour shade on surfaces of any description, exc. 10cm with or girth to external surface of DG sets by spray gun after necessary preparation of old surfaces complete all as specified and as directed by Engr-in-Charge. (Note:- Shade of paint to be approved by AGE(I).
SARASWATI ENTERPRISE (INDEX NO CEEC D-81)
LALAN SHARMA
M/S AMARNATH AGARWALLA
P .BANERJEE AND CO
M/S Subhadip Enterprise
M/S New Builders Corporation
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .