Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.3 LAccepted-AOC 212 B 8 PARDEWANPUR LAL BANGLA KANPUR 208007 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208007 | L1 | Accepted-AOC Being(L1) | |
| 2 | L2₹10.8 L+₹325 (0.03%)Rejected-Finance | L2 | Rejected-Finance Other than (L1) | |
| 3 | L3₹12.1 L+₹1.4 L (12.6%)Rejected-Finance | L3 | Rejected-Finance Other than (L1) | |
| 4 | L4₹15.8 L+₹5.0 L (46.7%)Rejected-Finance | L4 | Rejected-Finance Other than (L1) | |
| 5 | L5₹15.9 L+₹5.2 L (48.0%)Rejected-Finance 244 SHARDA VIHAR NEAR NEW HIGH COURT GWALIOR 474002 MP | GWALIOR | GWALIOR | MP | 474002 | L5 | Rejected-Finance Other than (L1) |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
27 Jul 2023, 6:00 pmClosed
GE (AF) E/M CHAKERI KANPUR
GE(AFEM Chakeri, Kanpur
REPAIR RENEWAL AND MAINT OF VARIOUS TYPES OF CEILING AND EXHAUST FANS AND CONNECTED MISC ELECTRCIALS ACCESSORIES WORK AT SNCOs ORs MD ACCN AT AGV AT AFS KANPUR
2023_MES_604939_1
8626E8
Open Tender
Civil Works
Item Rate
180 days
Area under GE(AF) EM Chakeri
As per tender documents
9 documents required · 9 mandatory
₹500
Yes
GE (AF) E/M CHAKERI
₹40,000
Yes
30 Aug 2023
22 Jun 2023
31 Jul 2023
22 Jun 2023
27 Jul 2023
7 Jul 2023
Amount
Taking down unseviceable ceiling fans of any sweep from site or collecting from existing position and transporting to local wksp for servicing by opening / dismantling of ceiling fans and cleaning externally and internally with washing soda / oil to remove oil stain and checking bearings, bushes, rubber bushes and reassembling the ceiling fans after making functional and hanging the same in its location complete all as directed by Engineer in Charge. Note: Spare items required to be replaced shall be measured and paid under respective items.
All as per item no. 1 here in before but Exhaust Fan of any sweep and type
M&L for preparation of old painted surface of ceiling fans of any sweep (1200/1400mm) and applying one coat of synthetic enamel paint (1st quality) with using spray painting machine and writing MES number with black paint or with black pernant marker pen complete all as directed by Engineer in charge.
All as per item no.3 here in before but one coat spray painting to Exhaust fan of 300 to 450mm sweep complete
M&L for rewinding of short circuit / over heated winding of ceiling fans of any make of 1200mm sweep with super enameled winding wire with same as per exisiting gauge , insulation materials and varnishing with super enamel vanish for proper insulation of winding complete all as directed by Engineer in Charge.
M&L for rewinding of short circuit / over heated winding of Exhaust fans of any make of 300mm sweep with super enameled winding wire with same as per exisiting gauge , insulation materials and varnishing with super enamel vanish for proper insulation of winding complete all as directed by Engineer in Charge.
M&L for rewinding of short circuit / over heated winding of Exhaust fans of any make of 450mm sweep with super enameled winding wire with same as per exisiting gauge , insulation materials and varnishing with super enamel vanish for proper insulation of winding complete all as directed by Engineer in Charge.
S&F electronic fan regulator, 5 stepped, flush type on the existing phenotic laminated sheet etc. all as specified and directed by Engineer in Charge.
S&F in replacement of ball bearing of suitable ceiling fans of suitable size (bearing no. 6201/6202 of approved make SKF/NBC as approved by GE
S&F in replacement of Canopy set of two suitable for ceiling fans (1200/1400mm sweep) of approved make and colour matched with colour of ceiling fans all as specified.
S&F in replacement of rubber real with nut & bolts, split pin etc. suitable for hanging of ceiling fans all as specified.
S&F in replacement of factory made down rod with clamps etc. suitable for ceiling fans, fabricted out from 15mm bore medium grade MS pipe , 300mm long complete with and including clamps, nut bolts, split pin all as specified and directed by Engineer in Charge.
Supply & Fix PVC connector block suitable for ceiling fans of suitable size complete all specified and directed.
S&F in replacement of capacitor of 2.5 MFD , 240 Volts, AC of approved make all as specified.
M&L in replacement of factory made alumnium metal ceiling fan blade (set of three) suitable size for ceiling fans 1200mm sweep duly painted with two coat of 1st quality sunthetic enamel spray paint all as specified and directed by Engineer in Charge.
M&L in replacement of factory made alumnium metal ceiling fan blade (set of three) suitable size for ceiling fans 1400mm sweep duly painted with two coat of 1st quality sunthetic enamel spray paint all as specified and directed by Engineer in Charge.
S&F PVC cable/wire for connecting ceiling fans to ceiling rose with copper conductor 3 core of size 23/0.0076 all as specified.
Supply only capacitor of 2.5 MFD , 240 Volts, AC of approved make all as specified.
Supply only electronic fan regulator, 5 stepped, flush type all as specified and directed by Engineer in Charge.
Supply, fix in replacement of energy saver LED light fitting 40 watt, single tube mounting , with and including LED tube/LED blocks 40 watt, Lumens out put not less than 100LM/watt with 50000 burning Hours, PF=0.95 complete with electronic driver, LED printed board, end cover, connector box etc. and acceossories, prewired, LED including required fixing arrangements and electrical connection with three core copper conductor cable from ceiling rose to LED light fitting all as specified and directed by Engineer in Charge. Cat part No. BN100C LED 40S-6500PSU L120GR of Philips / Cat Part no. LL24-541-XXX-57-XX/GE of Wipro / equivalent model in Havels as approved by GE.
S&F n replacement of energy saving LED, 4 feet Batten, 20/22 watt with a nominal syatem lumens out put 2400/2500 Lumens and a minimum system efficiency of 100 lm/watt with fixing arrangement and electricals connection wih three core copper conductor cable of size 23/0.0076 from ceiling rose to light fitting all as specified and directed by Engineer in Charge. Cat part No. BN021C LED 22S-PSU CW GR of Philips or equivalent model in Wipro / Havels as approved by GE.
Supply fix in replacement of enegy saving LED smart batten fitting10 watt, 230 Volt, box type etc. and acceories , including required fixing arrangement and lectricals connection with and inclding three core copper cable of suitable size from ceiling rose to light fitting complete all as specified and directed by Engineer in Charge. Cat part No. 10W 6500K D531065 of Wipro or equivalent model in Philips / Havels as approved by GE.
Supply only ceiling fan of 1200mm sweep with Squirrel cage induction motor ,blade set of three blade, down rod with rubber real and nut bolts, spilt pins for hanging , canopy set complete all as specified and directed by Engineer-in-Charge.
Supply only exhaust fan, heav duty steel body, single phase, 230 Volt, size 300mm sweep , 1400 RPM complete with blade and frame and with and including metal louvers of suitable size complete all as specifed & directed by Engineer in Charge.
S&F in replacement of submain wiring with two run single core PVC-FRLS inslated unsheathed multistranded copper conductor cable of size 2.5 Sqmm and one run single core single core PVC-FRLS inslated unsheathed multistranded copper conductor cable of size 2.5 Sqmm as continuous earth wire drawn in exiitng conduits complete all as specified and directed by Engineer in Charge.
S&F in replacement of submain wiring with two run single core PVC-FRLS inslated unsheathed multistranded copper conductor cable of size 4.0 Sqmm and one run single core single core PVC-FRLS inslated unsheathed multistranded copper conductor cable of size 4.0 Sqmm as continuous earth wire drawn in exiitng conduits complete all as specified and directed by Engineer in Charge.
S&F in replacement of submain wiring with two run single core PVC-FRLS inslated unsheathed multistranded copper conductor cable of size 6.0 Sqmm and one run single core single core PVC-FRLS inslated unsheathed multistranded copper conductor cable of size 6.0 Sqmm as continuous earth wire drawn in exiitng conduits complete all as specified and directed by Engineer in Charge.
H S ENTERPRISES
M/s A S Electrical
M/S NILESH ENTERPRISES
Uma engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .