Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹21.8 LAccepted-AOC 1ST FLOOR BL 8 6 DR B C ROY SARANI JYANGRA BAGUIHATI KOLKATA 700059 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700059 | L-1 | Accepted-AOC 1st lowest | |
| 2 | L-2₹21.9 L+₹10,000 (0.46%)Rejected-Finance 334 1 SCHOOLDANGA BANKURA 722101 | BANKURA | WEST BENGAL | 722101 | L-2 | Rejected-Finance 2nd Lowest | |
| 3 | L-3₹22.0 L+₹20,000 (0.92%)Rejected-Finance VILL P O JAMBEDIA DIST BANKURA PIN 722139 | JAMBEDIA | BANKURA | WEST BENGAL | 722139 | L-3 | Rejected-Finance 3rd Lowest |
Tender Value
Refer Docs
EMD Value
₹43,603
Closing Date
4 Apr 2023, 12:30 pmClosed
Executive Engineer,Bankura Electrical Division,PWD
PWD Compound, Kenduadihi, Near Bhairabsthan,Bankura-722102
E.I. Work for inverter system, SITC of solar grid system and SITC of lighting arrester with necessary electric connection and solar street light along with application process of net metering connection from WBSEDCL at 1. Bheduasole Women SHG Disari
2023_WBPWD_497566_1
WBPWDTE/EE/BED/NIQ_160/Q of 2022-23
Open Tender
ELECTRICAL WORKS ORG
Item Wise
30 days
Bankura Electrical Division
Please refer Tender documents.
3 documents required · 3 mandatory
₹43,603
Yes
23 May 2025
22 Mar 2023
6 Apr 2023
22 Mar 2023
4 Apr 2023
22 Mar 2023
Amount
SECTION A Distribution wiring in 1.1 KV grade 3x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire partly in 20mm size PVC rigidconduit 'FR' (Precision make) [for ceiling portion only] and in19mm bore, 3mm thick polythene pipe [for horizontal &vertical run embedded in wall] to light / Fan point as per GS withfollowing average run. 10 Mtr. [ 5(d) /E-9 ]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the (31*31) cutting channel with electric operated within polythene pipe and by the prelaid GI fish wire and making necy. connection as required 3 x (1.5 sqmm) [1(b) / E- 9 ] & E-2(5)
2x(2.5 sqmm)+1x(1.5 sqmm) [ 1(s) / E-9 ] & E-2(5)
2x (6 sqmm) + 1x (4 sqmm) [ 1 (y) / E- 9 ] & E-2(5)
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS. (Make: ABB) (2+14) way
6-32 DP (make: ABB) [ 7 / D- 6]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-ABB ] 32 A Dp
SECTION B Solar Module: Supply of MNRE(Ministry of Renewable Energy,Govt. of India)/ IEC approved 300-335 Wp Solar Module of multicrystaline cell with min. efficiency of 15% and fill factor more than 70%, laminated between sheet of -Ethylene Vinyl Acetate (EVA)and high transmissivity 3.2 mm tempered glass, framed in anodized aluminium frame .The power output of individual Lpv modules used in the PV array, under STC, with adequate provision for measurement tolerances. Modules supplied with the Spy system should have certificate as per IEC61215 specification or equivalent National or International standards. Modules must qualify to IEC61730 part I and part II for safety qualification testing and Salt Mist Corrosion Testing asper IEC61701/IS 61701.and having warranty for output wattage, which should not be less than 90%at the end of 10 years and 80%at the end of 25 years. ( Make: Tata solar power approved)
Supply, delivery & Erection of pre-fabricated M.S. steel structure of pable of extreme weather conditions including wind trust up to 120 KM/Hour with fixing of necessary MS ladder/railing and painting with appropriate weather coats including construction of R.C.C. foundation and all allied works as per approved drawing and direction of the E.I.C. Each structure should have angle of inclination as per the site conditions to take maximum isolation. The mounting structure steel shall be as per latest IS 2062\1992 standard and the galvanization of the mounting structure shall be in compliance of the latest IS for the structural material should be corrossion resistance and electrolytically compatible with the materials used to construct the module frame, including fastener, nuts and bolts. The thickness of the galvanization should be more than 75 Micron.Necessary protecdon towards rusting need to be provided either by coating or anodization.The minimum clearance of the structure from the roof level should be 300 MM. Design to be approved by EIC before fabrication. (Make: TATA Solar power approved)
Supply testing commissiong of 1 no pv Array Junction Box with A)The junction are to be provided in the SPD WITH IP 65 ENCLOSER AND ACDB WITH SPD AND IP 65 ENCLOSER 32 A MCB ,40 KA ac SPD. And for dcdb 32 A dp mcb and Dc spd. P.C Distribution Panel Board {DPB) shall control ltie AC power kom PCU/ inverter and should have necessary surge errestors. interconnection Tom ACDB to mains at LT Bus bar. Designed for 20 KWP solar power plants with all protections as per MNRE guidelines. DC DPBs shall have sheet form encloser of dust and vermin proof conform to IP 65 protection. The bus bars should be made of Copper of suitable size and of suitable capacity fuse and MCBs / MCCB shall be provided for controlling DC power output, to the PCU along with suitable surge rectors. AC power distribution panel board (DPB) shall control the AC power from PCU/Inverter and should have necessary surge arrestors. Interconnection from SEDB to Mains at LT Bus bar while in grid tied mode. All switches and the circuit breakers connectors should come from to IEC 60947 part 1, 2 and 3. Is 60947 Part 1, 2 and 3. All the panels shall be meta clad totally enclosed rigid floor mounted air insulated cubicle type suitable for operation on 3 phase / single phase 415 or 230 volts. 50 Hz all indor panels will have protection of ip 54 or better. All outdor panels will have protectionof IP65 or better. ( Make: TATA solar power appoved)
ACDB 16 SWG poder coated, Double Door with IP 42/43 protection along with all necessary connection ( Make: TATA solar power appoved)
Pure sine wave inverter with rated output power 3500VA, 1600 W,(200-240 V )with charging current(8A-21A) for optimize performance, advance led display to show battery performance and with bypass switch to supply output to grid in case of faliure with IP 65,IP 20 protection,operating temparture -20 to 55 C, .(make: Luminious) along with 12 V, 150Ah Tubular plate design,over charge protection lead- acid batteries for sitable performance. ( Make: Luminious) single input single phase out put
DC cable 1C*4 Sq mm, 1.1KV grade for Solar (finolex/RR or tata power solar approved)
1.1 Kv grade 3C* 10 Sq mm PVC copper cable (finolex/RR or tata power solar approved)
1.1 Kv grade 3C* 16 Sq mm PVC copper cable (finolex/RR or tata power solar approved)
Earthing kit (Rod, compound, Clamp)
Earthing Cable 1C* 10 Sq mm
Installation Kit, Terminal Ring and pin,MC 4 couplers, ties and all other accessories and Required CIVIL work.
Installation, Testing, commissioning of all above stated solar system and Transportation Charge
SECTION C Supply and installation by OEM or Authorized channel Partner of OEM, of external, wide area, early steamer emission OPR 30 type lightning arrester made of robust stainless steel & tested Standard stated in French Standard NF C17- 102, and IEC 62305-2. It is capable of polarizing the tip with a voltage of 600V to 10-20kV/m synchronized with an approaching lightning and triggering a powerful upward streamer with speed of 1m/µs into the air, with average time gain of 25 microseconds earlier than naturally formed streamers. Its upward streamers are strong enough to withstand applicable cyclonic wind speeds.The serial number displayed on the ESE lightning arrester shall be duly supported with the "certificate of country of origin" issued indicating the serial number of the product supplied. The ESE terminal must offer protection radius of 48 Mtrs. in Protection Level - I (high protection) and preferably to be mounted on the roof top of the building. ( Make: ABB)
Supply and installation by OEM or Authorized channel Partner of OEM of stainless steel support Mounting Mast 30 mm dia to hold early steamer emission OPR 30, of robust design with guy wire and base plate alongwith all accessories like clamps, shaddles, holding arrangements to fix mast to building structure at highest point such that the air terminal is 5 mtrs above the tallest structure Mounting Mast. (2 Mtrs. and 3 Mtrs. with Guy wire and Base Plate)
Supply and installation of lightning Stroke Counter by OEM or Authorized channel Partner of OEM working electro mechanically without any power supply.The recorder shall be of non-resettable type with the electro-mechanical display. No LCD screen is permittted as it may depend upon the battery life to energize the LCD. The lightning stroke recorder shall be duly tested & certified inline with the ESE lightning arrseter in an international labortaory for an impulse current (8/20 micro sec) and should count lightning strokes of 0.4 Ka to 150 Ka. ( Make ABB )
Supply and Laying of Down Conductor G.I.Strip of 50/6 mm ( length - As per Actual), both Verticle and Horizontal, clamping by saddles not exceeding 500 mm apart with 35/8" screw for fixing in wall complete with full threaded bolts with nuts and double washers incl. mending good damages to building work. Finishing the ends of the above Strip by Nut and Bolts, etc.
Hiring charges for Scaffolding arrangement including dismantling at the end of work and carriage, for ESE OPR 30 LA installation.
Supply and Installation by OEM or Authorized channel Partner of OEM of Medium Pipe (10 ft. long, 2" dia G.I.Pipe along with earth rod and Chemical Gel filled with highly conducting metallic compounds with permenant sealings at both ends - ( Make Standard, ISI Brand )for Earthing and for inter connection of Earthing under ground (of 3 meters X 1nos. per pit) with 3 Earth pits of 10 feet deep each.
Supply and Laying of maintenance free earthing terminal which consist of Ground Resistance Improving Furse Cem Conductive Aggregate material, tested as per BS. 1 bag of 25 kg. per Pit, to make it maintenance free and provide low resistance in the earth terminal to be executed by OEM or Authorized channel Partner of OEM only.
Application process of Net metering from WBSEDCL for solar grid system including net metering charge and new service connection or load enhencement charge upto 6 KW.
15 W Led Street light (two in one), dusk to dawn, 4 hrs 100% rest 50% with automatic charge controller, 75 Wp solar panel and 18 Ah lifepo4 battery in 6 meter hot dip galvanized pole with 1 meter underground with concrete base. (MNRE approved matarial)
After complition of project vendor should provide two years of ongrid solar system(6 KW) maintanance or menufacturer ensure product warranty for same.
After two years maintanence, service or product extended warrantyfor solar grid system (6 KW) for 1st year
After two years maintanence, service or product extended warrantyfor solar grid system (6 KW) for 2 nd year
After two years maintanence, service or product extended warrantyfor solar grid system (6 KW) for 3 rd year
TAPAN KUMAR SARKAR
UJJWAL MUKHERJEE
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .