Tender Value
₹23.5 L
EMD Value
₹47,000
Closing Date
22 Feb 2023, 5:00 pmClosed
XEN Electrical Division No. 1 Shimla
The Executive Engineer Electrical Division No-1 HPPWD Shimla-9
SH Providing 5 KVA inverter therein
2023_PWD_68967_1
Electrical Division-I dated 8.02.2023
Open Tender
Electrical Works
Item Rate
180 days
SHIMLA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
E.E.Electrical Division No-I Shimla-9
₹47,000
18 Jun 2023
16 Feb 2023
23 Feb 2023
16 Feb 2023
22 Feb 2023
16 Feb 2023
Amount
Supply Installation testing and commissioning of 5 KVA Inverter, Suitable for AC Single phase input 185 to 260V ± 5V and AC Single Phase Output 230 v (UPS mode), 50 HZ±1 %. Pure sine wave output, for low noise and smooth operation, SMD based design, LCD Display,Thermal Protection, Static Bypass, No load shutdown and as required complete in all respect and as per the satisfection of Engineer-in-Charge.warrenty of the peoduct should be minimum 24 months Make Luminous,microtek etc or other approved make by Engineer-in-charge.
Supply Installation testing and commissioning of tubular Battery 135 Ah/12 V LA Battery for backup for inverter for unerrupted suppy pure sine wave output, for low noise and smooth operation,as required compleate in all respect and as per the satisfection of Engineer-in-Charge. battery warrenty should be minimum 42 months Make Amaron,luminious excode , or other make as approved by engineer in charge
Supply Installation of Angle Stand for the battery and inverter placement along with the Rack and interlinks as rquired complete in all respect and as per the satisfection of Engineer-in-Charge.
Supplying and fixing following way, CRCA sheet steel enclosure, IP 30 - Metal Door, RAL9003, powder coated, suitable for surface and flush mounting, with provision to mount MCB/Isolator/RCCB/RCBO and other modular devices, including interconnections, earthing etc. as required. (But without MCB/RCCB/Isolator etc.)
MCB Enclosure 2/3 or 4 way
Supplying and fixing Higher Rating (80 to 125A) 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
MCB DP 50/63 A 'C' curve
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 1.5 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Elsan Electricals Eneterprises
SHARMA ELECTRICAL CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .