The Director, CSIR-CLRI
CSIR-CLRI, Adyar, Chennai-600020
Renovation of the workshop (northern side of Museum Building) attached to CARE unit at Museum Building, CSIR-CLRI, Adyar, Chennai-600020
2022_CSIR_136093_1
CLRI/36(2)/2022-23/Wks
Open Tender
Civil Works
Item Rate
180 days
CSIR-CLRI, Adyar, Chennai-600020
Please refer Tender documents.
9 documents required · 9 mandatory
₹0
₹82,028
Yes
26 Dec 2022
24 Nov 2022
7 Dec 2022
24 Nov 2022
6 Dec 2022
24 Nov 2022
Amount
CIVIL PART - REPLACEMENT OF OLD VENTILATORS WITH UPVC SECTION AND FLOORING
Providing and fixing factory made uPVC white colour sliding glazed window up to 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to Upvc profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be metered cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Note: For uPVC frame and sash extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable. Two track two panels sliding window made of (small series) Frame 52 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window up to 1.75 sqm)
Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: Of area 3 sq. metres and below
CIVIL PART - PROVIDING ALUMINIUM PUF ROOF PANEL AT CARE -WORK SHOP SHED
Providing and fixing on wall face un plasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter.
Providing and fixing on wall face un plasticised - PVC moulded fittings/accessories for un plasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° 110 mm bend
Providing and fixing on wall face un plasticised - PVC moulded fittings/accessories for un plasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.110 mm Shoe
Providing and fixing un plasticised -PVC pipe clips of approved design to un plasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc.complete.110 mm
Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified.2 mm thick Flat sheet
Providing and fixing of Pre-coated colour galvalume or mill finish Aluminium Roofing Accessories in 0.71 mm thickness, Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)] For colour, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling / tapping SS screws of size 6 x 50mm with 3mm thick EPDM seal and SS plain washer complete : Pre coated colour galvalume / mill finish aluminium Ridges plain (500-600mm)
Providing and fixing of Pre-coated colour galvalume or mill finish Aluminium Roofing Accessories in 0.71 mm thickness ,Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)] For colour, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling / tapping SS screws of size 6 x 50mm with 3mm thick EPDM seal and SS plain washer complete : Pre coated colour galvalume /mill finish aluminium Crimp curve
Providing and fixing of Pre-coated colour galvalume or mill finish Aluminium Roofing Accessories in 0.71 mm thickness, Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)] For colour, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self-drilling /tapping SS screws of size 6 x 50mm with 3mm thick EPDM seal and SS plain washer complete : Pre coated colour galvalume /mill finish aluminium Gutter600 mm over all girth)
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: asbestos Cement sheet
CIVIL PART - RENEWAL OF EXISTING TRUSS PAINTING WORKS IN THE CARE - WORKSHOP SHED
Applying priming coat with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work
CIVIL PART - INTERNAL AND EXTERNAL WALL & FRONT ELEVATION PAINTING WORKS
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @1.25 ltr /10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm.
Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two or more coats on new work
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
CIVIL PART - EXTENDING SUPPLY LINE TO LABORATORY SINK
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 15 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes
Providing and fixing gun metal non- return valve of approved quality (screwed end) : 25 mm nominal bore Horizontal
CIVIL PART - PROVISION MADE FOR WASTE WATER DRAINING FACILITY
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 100 mm diameter .
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1(1 cement : 1 fine sand) including testing of joints etc. complete :150 mm diameter
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : 150 mm diameter S.W. pipe.
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 180x150 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 100 to 250 mm diameter
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 Fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With commonburnt clay F.P.S. (non modular) bricks of class designation 7.5
CIVIL PART - MISCELLANEOUS WORKS DEMOLISHING INTERNAL WALL, EXISTING DOOR CLOSING (NW END) & OPENING OF NEW DOOR -CARE.
Brick work with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Second class teak wood.
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): Circular
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :250x16 mm
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :200x10 mm
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm
Providing and fixing carbon steel galvanised (minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole inframe, concrete / masonry,etc. as per direction of Engineer-in-charge.10 x 160 mm.
20 mm cement plaster of mix: 1:6 (1 cement: 6 coarse sand).
12 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand).
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar
Providing epoxy Flooring over the CC flooring including preparing the substrate and finishing the same as required by the EIC
Providing the puf panel roof having 50mm thk either side sandwich (insulating material) between 0.47mm on either side of JSW aluminium/Galvalume sheets for required length as specified in the drawing & approved by EIC including crimping at one end over the pre-existing profile structural member with all necessary fixtures required at the working height of 5.0 m to 8.0 m level.(Contractor shall take safety measures of its own).
Providing the roof mounted stainless steel standard chimney over the aluminium colour coated Roofing sheet @ height up to 8.0 m including all necessary charges as per the directions of the EIC.
Providing 100mm dia PVC tee along pipe line.
Providing 100mm PVC bend.
Providing the supporting bracket system for gutter in the CARE workshop.
Providing the 4.0 mm thk glass pane for UPVC ventilator with all necessary fixtures required.
Providing the silicone sealant with back rod packing along the either side of the Ventilator frame.
ELECTRICAL PART
POINT WIRING: Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medum class PVC conduit, with modular switch, modular plate, suitable G.I. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Make: LEGRAND/ ANCHOR ROMA/MK BLENZE.
4 SQMM X 3 CORE CIRCUIT WIRING: Wiring for power plug with 2X4 sqmm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sqmm FRLS PVC insulated copper conductor single core cable for loop earthing as required. Make:- Finolex/Polycab/Havells
2.5 SQMM X 3 CORE CIRCUIT WIRING:Wiring for circuit wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 3x2.5 sq mm Make:- Finolex/Polycab/Havells
4 SQMM X 3 CORE CIRCUIT WIRING:Wiring for circuit wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 3x4 sq mm Make:- Finolex/Polycab/Havells
4 SQMM X 6 CORE CIRCUIT WIRING: Wiring for power plug with 4X4 sqmm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 2 No's. 4 sqmm FRLS PVC insulated copper conductor single core cable for loop earthing as required. Make:- Finolex/Polycab/Havells
2.5 SQMM X 3 CORE CIRCUIT WIRING IN EXSITING: Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required. Make:- Finolex/Polycab/Havells
4 SQMM X 3 CORE CIRCUIT WIRING IN EXSITING: Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required. 3x4 sq.mm Make:- Finolex/Polycab/Havells
25MM PVC CONDUIT: Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 25mm PVC Conduit Make: AVONPLAST/SURYA
32MM PVC CONDUIT: Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 32mm PVC Conduit Make: AVONPLAST/SURYA
8 WAY SINGLE PHASE DB: Supplying and fixing way, horizonal type single pole and neutral, sheet steel MCB distribution board,240 V, on surface / recess,complete with tinned copper bus bar,neutral bus bar, earth bar din bar, interconnections, powder including earthing etc.., as required. (But without MCB / RCCB / Isolator) Make: Legrand/ L&T/Anchor/Havells 8 way Double door
8 WAY THREE PHASE DB : Supplying and fixing following way, vertical type,415V,TPN MCB distribution board of sheet steel, dust protected,duly powder painted,inclusive of 200A tinned copper busbar,common neutral link,earth bar,din bar for mounting MCBs (but without MCBs and Incomer) as required. 8 way (4 + 24), Double door Make: Legrand/L&T//Anchor/Havells
DOUBLE POLE MCB WITH METAL ENCLOSURE: Supplying and fixing DP sheet steel enclosure on surface / recess along with 16/25/32A 240V "C" curve DP MCB complete with connections,testing and commissioning etc .as reqired Make:Legrand/L&T//Anchor/Havells
SINGLE POLE MCB: Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole MCB Make:Legrand/L&T//Anchor/Havells
DOUBLE POLE MCB: Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole MCB Make:Legrand/L&T//Anchor/Havells
CABLE END BOX: Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required. Make:Legrand/L&T//Anchor/Havells
2 MODULAR BOX WITH COVER PLATE: Supplying and fixing following size /modules,GI /PVC box along with modular base & cover plate for modular switches in recess etc.as required Make:Legrand/L&T//Anchor/Havells. 2 Module
3 MODULAR BOX WITH COVER PLATE: Supplying and fixing following size /modules,GI /PVC Flush box along with modular base & cover plate for modular switches in recess etc.as required Make: Legrand/Anchor Roma/MK Blenze or its Equivalent. Make:Legrand/L&T//Anchor/Havells 3 Module
6 MODULAR BOX WITH COVER PLATE: Supplying and fixing following size /modules,GI /PVC Flush box along with modular base & cover plate for modular switches in recess etc.as required Make:Legrand/L&T//Anchor/Havells/MK Blenze 6 Module
FAN REGULATOR: Supplying and fixing Two module stepped type electronic regulator on the excisting modular plate switch box including connections but excluding modular plate etc.as required Make: Anchor/Legrand/Havells
MV CABLE LAYING IN WALL: Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following sizeon wall surface as required. 35sq.mm Aluminium armoured cable (Clamped with 1mm thick saddle)
MV CABLE LAYING IN EXISTING: Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following sizeon wall surface as required. 35sq.mm Aluminium armoured cable (Clamped with 1mm thick saddle)
DWC PIPE: Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket,bend,couplers etc.conforming to IS 14930,Part-II complete with fitting and cutting,jointing etc.direct in ground (75cm below ground level) including excavation and refilling the trench etc.as required.
END TERMINATION: Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 25 sq. mm (28mm)
END TERMINATION: Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm (28mm)
5A MODULAR SWITCH: Supplying and fixing following modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5A Switch Make:Legrand/AnchorRoma/MK/Havells
16 MODULAR SWITCH: Supplying and fixing following modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 16A Switch Make:Legrand/AnchorRoma/MK/Havells
6A 3PIN MODULAR SOCKET: Supplying and fixing following modular socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6A 3Pin Socket Make:Legrand/AnchorRoma/MK/Havells
16A 6PIN MODULAR SOCKET: Supplying and fixing following modular socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 16A 6Pin Socket Make:Legrand/AnchorRoma/MK/Havells
EARTH WIRE: Providing and fixing 6 SWG dia G.I wire on surface or in recess for loop earthing alongwith existing surface/recessed conduit/submain wiring/cable as required.
REMOVEL OF ELECTRICAL EXISTING PANEL BOARDS: Removing the existing panel board's and cables, wires, switch boards, light fittings & fixtures etc., and same can be Hand over to electrical department as directed by Electrical Engineer.
FOUR POLE 63A MCB: Supplying and fixing 63 A rating, 415 V, 25 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make:Legrand/L&T/Havells 63A FOUR POLE MCB
S/F CABLE MANAGER SYSTEM:Supplying and fixing of 105mm x 50mm size cable management system with all accessories etc., as required. Make: Legrand/MK/Anchor
JUNCTION BOX ON FLOOR: Supplying and fixing of floor mounting junction box for tile/ marble floor for direct acess to cables/ wires in PVC conduit/raceways with suitable connections, base cover and lid etc as required. Make: Legrand/MK/Anchor
SUPPLY AND FIXING OF CEILING FANS (With std down rod) : Supply and fixing of Brown/ Ivory/ Pale Brown colour, 1200mm sweep, double ball bearing 5 star rating BLDC ceiling fan (without regulator). The job includes supply & provision suitable down rod and making as required. Make: Crompton/Orient/Armonard
WALL MOUNTING FAN:Supply, installation and testing of 450mm sweep wall mounting fan (Make: Crompton/Usha/Almonard) with necessary oscillation control fixing clamps etc., as required Make: Crompton/Usha/Havells/ Orient 450MM
SUPPLYING AND FIXING OF EXHAUST FAN (300mm) : Supplying Installation and testing commissioning of 300mm Sweep Exhaust fan complete with all accessories.. etc, fixing in the existing hole / window grill and fixing accessories including connections with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc., as required . (The rate inclusive of required louver etc.,) Make: Crompton / Orient / Havells
HIGH BAY HANGING LIGHT FITTINGS-LED : Supply and fixing of LED-High bay fitting with all accessories on the existing truss/structure using suitable clamps/mounting arrangements etc., as required. Make:Crompton/Phillips/
SUPPLY OF 3.5 x 25 SQ MM, ALUMINIUM MV CABLE: Supply of 3.5 x 25 sq mm, PVC insulated, Sheathed and armored aluminium 1100 V grade UG cable conforming to IS 1554 and submit with necessary test certificate etc. as required. Make: Finolex/Polycab/Havells
SUPPLY OF 4 x 16 SQ MM, ALUMINIUM MV CABLE: Supply of 4 x 16 sq mm, PVC insulated, Sheathed and armored aluminium 1100 V grade UG cable conforming to IS 1554 and submit with necessary test certificate etc. as required. Make: Finolex/Polycab/Havells
TMS CONSTRUCTIONS
JPS Constructions
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .