Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 LAccepted-Finance | L1 | Accepted-Finance Lowest Bidder | |
| 2 | L2₹5.0 L+₹44,380 (9.79%)Rejected-Finance SRINIKETAN ROAD BOLPUR BIRBHUM 731204 | BOLPUR | BIRBHUM | WEST BENGAL | 731204 | L2 | Rejected-Finance Higher Bid | |
| 3 | L3₹5.4 L+₹88,780 (19.6%)Rejected-Finance NICHUPATTY BOLPUR BIRBHUM | BIRBHUM | WEST BENGAL | 713129 | L3 | Rejected-Finance Higher Bid |
Tender Value
Refer Docs
EMD Value
₹10,863
Closing Date
18 Jan 2025, 1:00 pmClosed
EE, South 24 Pgs Elect Divn
57/2 Diamond Harbour Road Kolkata-700023
Repair and Renovation of Guest House at Chakgaria Campus of west Bengal University of animal and Fishery Sciences the District of South 24 Parganas--- SITC AC machines.
2025_WBPWD_795959_1
WBPWD/EE/S24PED/eNIT110_2nd Call/24-25
Open Tender
A/C ORG
Item Rate
Chakgaria
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,863
South 24 Parganas Electrical Division
7 Feb 2025
7 Jan 2025
20 Jan 2025
7 Jan 2025
18 Jan 2025
14 Jan 2025
13 Jan 2025
Amount
Supply & Delivery of High-wall Split-type Air-Conditioner having following specification: Cooling Capacity - 3.8 kW (Minimum) Minimum ISEER - 3.8, BEE level - 3-Star(min)[1st July22 to 31st December 2024] IS Compliance - IS-1391(Part-I & Part-II) with all amendment Refrigerant - R410A/R32 Compressor - Rotary/Scroll Evaporator & Condenser Coil - Copper Operating outdoor temperature - 50ºC and above Power supply -230V, 50Hz (±tolerance asper applicable standard),as directed by EIC. The scope of work is also includes supply of following (i) Necessary refrigeration copper line with nitrile rubber insulation and wrapping tape - 3 mtr (ii) Necessary 3/4 core copper cable (FRLS type - make : Finolex/RR Kable/Polycab/Havells/Gloster) - 3mtr and suitable plug top(Anchor/North West/Legrand/Havells) [Make: O.General/Mitsubishi Electric/Zamils]
Supply & Delivery of High-wall Split-type Air-Conditioner having following specification: Cooling Capacity - 5.2 kW (Minimum) Minimum ISEER - 3.8, BEE level - 3-Star(min)[1st July22 to 31st December 2024] IS Compliance - IS-1391(Part-I & Part-II) with all amendment Refrigerant - R410A/R32 Compressor - Rotary/Scroll Evaporator & Condenser Coil - Copper Operating outdoor temperature - 50ºC and above Power supply -230V, 50Hz (±tolerance asper applicable standard),as directed by EIC. The scope of work is also includes supply of following (i) Necessary refrigeration copper line with nitrile rubber insulation and wrapping tape - 3 mtr (ii) Necessary 3/4 core copper cable (FRLS type - make : Finolex/RR Kable/Polycab/Havells/Gloster) - 3mtr and suitable plug top(Anchor/North West/Legrand/Havells) [Make: General/Mitsubishi Heavy Duty/Mitsubishi Electric]
Supply & Delivery of High-wall Split-type Air-Conditioner having following specification: Cooling Capacity - 7.1 kW (Minimum) Minimum ISEER - 3.8, BEE level - 3-Star(min)[1st July22 to 31st December 2024] IS Compliance - IS-1391(Part-I & Part-II) with all amendment Refrigerant - R410A/R32 Compressor - Rotary/Scroll Evaporator & Condenser Coil - Copper Operating outdoor temperature - 50ºC and above Power supply -230V, 50Hz (±tolerance asper applicable standard), as directed by EIC. The scope of work is also includes supply of following (i) Necessary refrigeration copper line with nitrile rubber insulation and wrapping tape - 3 mtr (ii) Necessary 3/4 core copper cable (FRLS type - make : Finolex/RR Kable/Polycab/Havells/Gloster) - 3mtr and suitable plug top(Anchor/North West/Legrand/Havells) [Make: General/Daikin/Mitsubishi Electric]
Installation of Split AC
Installation, Testing & Commissioning of Indoor & Outdoor unit of above Hi wall split AC machine after making hole in wall etc as per direction of EIC including Supply of required Refrigerant, S&F of necessary fixing arrangement for indoor and 40 x 40 x 5 mm MS angle iron frame for outdoor unit (or arrangement recomended by Manufacturer), duly painted, laying and making connection of refrigeration pipe, power cable, drain pipe etc as per direction of the EIC.
S&F of additional following items for length exceeding 3 mtr for complete installation and commissioning of aboove AC machines. (i) Supply & Fixing of extra refrigerant pipe(as requisite dia) with nitrile rubber insulation and wrapping tape [each mtr Refrigerent pipe will include cost of 1 metre liquid pipe line and 1 mtr gas pipe line of required dia and other accesories as required].
S&F of additional following items for length exceeding 3 mtr for complete installation and commissioning of aboove AC machines. i) 2.5 sqmm ,3/4 core copper cable (FRLS type - make : Finolex/RR Kable/Polycab/Havells/Gloster)
Supply & laying Soft Drawn PVC Drain Pipe 19mm dia with proper supports & brackets as per direction EIC. (Make: Suprime/Oriplast)
Note: 1. The Agency must procure the materials from the manufacture / OEM or from their authorised sales channel so that the standard warranty/support of the manufacture / OEM becomes applicable to the products to be delivered and installed by them. 2. Documents that authenticates such procurement from the manufacture / OEM or from their authorised sales channel and standard warranty/support should be sent from the e-mail of the manufacture / OEM / authorised sales channel to the e-mail of Engineer-in-charge and hard copy of it to be submitted during execution of work/submission of Bill. 3. If any refurbished material is supplied and installed, Penal action will be will be taken as per existing rules. 4. All the above rates should be quoted inclusive of all taxes, duties and all ancilery charges with cost of maintenance, servicing, supply & replacement of spares for 1 (One) year from the date of commissioning. 5. Total is rounded off to the nearest rupees.
RAMKRISHNA ELECTRONICS (BID ID -6004783)
MOON LIGHT (BID ID -5999664)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .