Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.0 LAccepted-AOC H NO 496 SECTOR 10 GURGAON 122001 HARYANA | GURGAON | GURGAON | HARYANA | 122001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹28.4 L+₹3.4 L (13.4%)Rejected-Finance 29 108 A STREET NO 10 VISHWAS NAGAR DELHI 110032 | DELHI | SHAHDARA | DELHI | 110032 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹29.4 L+₹4.4 L (17.6%)Rejected-Finance PLOT NO 79 SIS PARK DICHAON ENCLAVE PP2914 NAJAFGARH SOUTH WEST DELHI NEW DELHI 110043 | WEST DELHI | DELHI | 110043 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹29.5 L+₹4.5 L (17.9%)Rejected-Finance 127 OLD NAGAR PALIKA BUNGLOW NO 60 NEEMUCH MP NEEMUCH MADHYA PRADESH 458441 INDIA | NEEMUCH | MADHYA PRADESH | 458441 | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹31.0 L+₹6.0 L (23.9%)Rejected-Finance A 212B GALI NO 1 SHAKARPUR DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
3 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE South Delhi Cantt-10
GE South Delhi Cantt-10
REPAIR TO EXTERNAL WALL PLASTER, MUMTY PLASTER, CHAJJAS, RAINWATER PIPES, PARAPET WALL AND PERIODICAL SERVICES TO CERTAIN BLDGS AT VASANT RANGE COLONY UNDER AGE B/R-I OF GE (SOUTH) DELHI CANTT-10
2024_MES_636195_1
GE/DS-94/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE South Delhi Cantt
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE South Delhi Cantt
₹70,000
Yes
21 Feb 2024
6 Jan 2024
5 Feb 2024
6 Jan 2024
3 Feb 2024
20 Jan 2024
Amount
Demolition of brick work built in cement mortar, including all quoins, arches, pillars etc of any description including removing debries from site complete all as specified and as directed.
M&L for brick work with sub class `B' bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and as directed.
M&L for chipping of spelled and loose concrete and cleaning rust from reinforcement by sand blasting, scrubbing down concrete surfaces with wire brushes cleaning with water allowed to dry applying a layer of zinc rich epoxy primer as anti rust on all exposed reinforcement followed by a layer of bonding coat of a layer of epoxy adhesive on complete exposed surfaces of concrete and provide gunniting in two layers over steel welded mesh 2 mm dia of wire and total aperture 75 mm, thickness of gunite n.exc 25 mm thick (average thickness) using cement mortar 1 :2 with OPC 43 grade cement mixed with polycrete admixture @ 2 % by weight of cement or as per manufactures instructions and finally applying cement plaster over gunite surfaces of required thickness to give an even uniform and smooth finish conforming to proper geometrics in cement mortar 1:4 to match with the existing surface as in side and soffits of slabs, chajjas, fins, facias, parapets, columns and beams etc complete including necessary scaffolding , shuttering necessary chased to brick work or RCC members at any height upto full height of buildings including removing of small trees shrubs etc complete all as specified and as directed. Note: Steel mesh to be welded with the existing reinforcement. The cost of welded mesh is deemed to be included in the unit rate quoted.
M&L for polymer modified mortar as in patch repairs 25-30 mm total average thickness (in 2 layers) incl necessary form work as per site requirement up to 4th floor level in Slabs complete all as specified and as directed.
M&L for polymer modified mortar as in patch repairs 50-60 mm total average thickness (in 3 layers) incl necessary form work as per site requirement up to 4th floor level in Beams and Columns complete all as specified and as directed.
Notes for Ser No 4 and 5 here in before Polymer modified mortar repairs shall be done as per following methodology:- (i) Chipping of plaster and unsound/weak concrete material till reinforcement bars are exposed, which enables their rust removal vide note (ii) below, from slabs, beams, chajjas, balconeys, and columns etc. with standard power driven percussion type or pneumatic chisel of standard make as directed by Engineer-in charge including tapering all edges, making square shoulders of cavities etc. complete and disposal of debris up for all lifts and leads. (ii) Rust removal by Providing and applying Reebaklens RR of Fosroc or equivalent from approved makes specified in Appendix ' B' to particular specification, a combination of acid based material, corrosion inhibitors and dispersing agents rust remover, for removal of all rust/ scales/corrosion from reinforcement bars before micro concreting or patch repair, It Shall be applied with brush for complete wetting of rusted metal surface at coverage of 2- 2.5 Sqm/litre & allow it to react for 16-24 hours. After 24 hours, a white layer will appear which will protect further corrosion of metal /steel for.
(iii) Anticorrosive treatment by Providing and applying Nitozinc Primer of Fosroc or equivalent from approved makes specified in Appendix 'B' to particular specification, an epoxy based zinc rich anti corrosive primer having adhesive bond strength ≥ 1.5 MPa as per ASTM D4541, & shall comply to per ASTM B-117 to be applied on well cleaned, fully exposed and all loose scale , rust free surface obtained by grit blasting or suitable means, to be done with coverage @4.5sqm/litres to achieve a minimum thickness of 40microns DFT or as per direction of Engineer-in-Charge. (iv) Epoxy bonding for Old concrete & New concrete by providing and applying bond coat on the prepared surface with two component epoxy based bonding coat Nitobond EP of Fosroc or equivalent from approved makes specified in Appendix 'B' to particular specification, having specific gravity 1.15 to 1.2 gm/cc, Compressive strength(BS 6319 Pt.2)- 50 Mpa at 7 days, Flexural strength strength(BS 6319 Pt.3)- 35 Mpa at 7 days, Tensile strength (BS 6319 Pt.7)-20 Mpa at 7 days, Shear Strength (BS 6319 Pt.4)-10 Mpa at 7 days, having an over lay time of 6 hrs and 30 ̊C. Bonding agent shall have coverage not less than 2.5sqm/litre. Laying of reinstatement polymer modified mortar or micro concrete shall be completed within the overlay time of bonding coat.
(v) Polymer modified mortar by providing and laying single component, polymer modified, fibre reinforced cementitious repair mortar, Rendroc SP40 or equivalent from approved makes specified in Appendix 'B' to particular specification, over the tacky bond coat, that achieves Compressive strength (BS 1881 Pt.116)>20 MPa at 1 day, >45 Mpa at 28 days, Tensile Strength >2.5 MPa, Flexural Strength>7Mpa at 28 days, Finishing the same with trowel carefully compacting the same around the rebars and finishing to bring it in line with existing concrete surface on the beams, slabs, piles etc., complete in all aspect as per manufactur's methodology. (vi) Work shall be completed only after proper wet curing has been done by contractor and surface has been evaluated for satisfactory quality by sounding/tapping with a blunt metal instrument, and testing of Polymer modified mortar cubes filled up and cured. (vii) Unit rates quoted for Polymer modified mortar 25-30 mm and Polymer modified mortar 50-60 mm (against items 4.00 and 5.00 respectively) are inclusive of all materials, labour, tools and plants, propping, scaffolding, formwork, safety arrangement, quality control, testing etc. and all items of works included in notes (i) to (vi) above.
Taking down cement plaster on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and as directed.
M&L for 15 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar 1:4 upto 4 story building , to be finished even and fair with water proofing compound by weight as per manufacturer's instructions complete all as specified and as directed. Note : WPC will be measured and paid separately.
M&L for 15mm thick rendering in CM 1:6 of brick/ concrete surface finished fair even and smooth wihout using extra cement and then applying a coat of liquid water proofing compound as per manufacturers instruction over newly plastered surface complete all as specified and as directed.
M&L for 10mm thick rendering in CM 1:3 on ceiling mixed with bonding agent as per manufacturing instructions and finished fair even and smooth without using extra cement complete all as specified and as directed.
M&L for preparation and application of two or more coats of acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm as per manufacturer's instructions. The paint should also be 100% anti-fungal, damp proof, weather proof over and including water proof wall care putty to achieve even and smooth surface over new plastered surfaces of walls and ceilings complete all as specified and as directed.
M&L for complete removal of existing treatment by mechanical means and applying two coats of acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm as per manufacturer's instructions. The paint should also be 100% anti-fungal, damp proof, weather proof over and including water proof wall care putty to achieve even and smooth surface over old plastered surfaces of walls complete all as specified and directed.
M&L for Preparing new plastered or unplastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed.
Supply only liquid water Proofing Compound complete all as specified and as directed.
Taking up or down 15mm bore steel tubing and connections including removing from site complete all as specified and as directed.
Taking up or down 20mm bore steel tubing and connections including removing from site complete all as specified and as directed.
Taking up or down 25mm bore steel tubing and connections including removing from site complete all as specified and as directed.
S&F 15mm bore GI tubes, medium grade galvanised, with all fittings and fixed complete to walls and ceilings or laid floors or concealed complete all as specified and as directed.
S&F 20mm bore GI tubes, medium grade galvanised, with all fittings and fixed complete to walls and ceilings or laid floors or concealed complete all as specified and as directed.
S&F 25mm bore GI tubes, medium grade galvanised, with all fittings and fixed complete to walls and ceilings or laid floors or concealed complete all as specified and as directed.
Dismantling of brick tiles (laid flat or on edge) on roof surface.laid bedded and pointed in any mortar complete all as specified and as directed.
Demolition of mud in roof, any thickness, including plastering and leeping incl necessary scaffolding arrangement complete all as specified and directed(whether full thickness removed or only a part there of) and removing from cantonment area or complete all as specified and as directed.
M&L for brushing neat cement slurry with 1.00 Kg of cement per Sqm on existing surfaces complete all as specified and as directed.
M&L 75 mm thick (average thickness) plain cement concrete 1:2:4 type B-0 using (12.5 mm graded aggregate) with water proofing compund @ 3 % of cement, as in roof, padding to maintain the uniform slope complete all as specified and as directed. Note:- (a) WPC shall be measured separately and PCC shall be mix by concrete mixer. (b) Padding on water staging shall be done after disconnecting water tank , move a side and to be reconnected same day. (c) water supply to affected quaters to be arranged by providing flexible connection or otherwise by contractor. d) Removal of sapling/bushes and anyother obstruction and filling hole, rate included. (e) Including Removing and refixing of Dish entenna and other acessories if any to suitable place or as directed by Engr-in-Charge.
M&L for rendering 10 mm thick (average) plaster on concrete surfaces in CM (1:4) on roof, mixed with water proofing compound as per manufacuring instructions and finishing the surface even and smooth without using extra cement complete all as specified and as directed.
M&L for Priming roof surfaces and applying water proofing treatment over roofs comprising of the following complete all as specified & as directed:-
(a) Applying oil bound bituminous primer at the rate of 0.30 Ltrs/Sqm as per IS 3384-1986 on prepared surfaces. Surface shall be kept free till the moment, the primer is impregnated and the solvent oil in primer is evaporated.
(b) Applying one coat of hot straight run bitumen @ 1.20 Kg/Sqm of grade 30/40 confirming to IS-73 (Grade S-35).
(c) Laying 3mm thick APP polymeric water proofing membrane of weight not less than 3.6 kg/sqm, black finish reinforced with non woven polyster matt, (weight not less than 160 gm/Sqm) with a thermo fusible finish, torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at sides and 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufacturer's instruction including preparation of surface.
(d) Make of APP : "Moply FP" manufactured by STP Texsa Ltd or Hyper Plas (Polyester) manufactured by M/S IWL Ltd or "Shaliplas"ter) manufactured by M/S Capital Steels and Chemical Pvt Ltd or Makpolyplast manufactured by M/S M K Patro as approved by GE.
Note:- The water proofing treatment shall be got carried out by the manufacturer or their authorised applicators. The contractor shall give 10 years guarantee for effectiveness of water proofing treatment, 2.5% of work done amount of this item shall be retained from contractors payment for a period of 10 years reckoned from date of physical completion of this work, or in lieu contractor may deposit bank FDR for the said amount for 10 years which shall be released by GE on expiry of satisfactory completion of 10 years period.
M&L for cement concrete tiles with white cement and pigment size 30 cmx 30 cm x 22mm thick laid over and including 20mm thick screed in cement mortar 1:6 and jointed grouted and pointed in CM 1:3 complete all as specified and as directed.
M&L for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in roof kerbs or mud stops, rounded or chamfered and hold fast on edge including necessary form work complete all as specified and as directed.
M&L for complete removal of existing treatment from internal surfaces of walls or a part thereof (In Patches), area exc. 1.00 Sqm but not exceeding 3.00 Sqm, which is damage due to seepage or any other reason & preparing and levelling the disturbed surfaces by using wall care putty (JK/Birla white) to obtain even and smooth wall surfaces over application for two or more coat of Dr Fixit or equivalent chemical treatment of that portion and using sand paper and than applying two coats of oil bound distemper over a coat of primer, including scaffolding arrangement, trestles, ladders, complete all as specified and as directed.
M&L for complete removal of existing treatment from internal surfaces of walls or a part thereof (In Patches), area exceeding 3.00 Sqm but not exceeding 5.00 Sqm , which is damage due to seepage or any other reason & preparing and levelling the disturbed surfaces by using wall care putty (JK/Birla white) to obtain even and smooth wall surfaces over application for two or more coat of Dr Fixit or equivalent chemical treatment of that portion and using sand paper and than applying two coats of oil bound distemper over a coat of primer, including scaffolding arrangement, trestles, ladders, complete all as specified and as directed.
Taking down eaves gutter rain water RCC/PVC pipe (75mm/110mm bore) including all fittings, heads, shoes, bends, swan-necks and cleaning or fixing or removal complete all as specified and as directed.
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including suitable clamps at one meter of interval complete all as specified and as directed.
S&F PVC (SWR) bends/Tees of radius, suitable for 110mm dia PVC pipes fixed complete all as specified and as directed.
S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including suitable clamps at one meter of interval complete all as specified and as directed.
S&F PVC (SWR) bends/Tee etc of radius, suitable for 75mm dia PVC pipes fixed complete all as specified and as directed.
S&F in repairs 15 mm size brass chromium plated Two way angle valves fancy type cast copper alloy complete all as specified and as directed.
S&F in repairs Grating doom 100 mm dia of PTMT (Minimum weight 25gms) including fixing with 1:4 C:M to floor/nahani traps etc. complete all as specified and as directed.
S&F in repairs 125mm x 100mm PVC gully traps square & round mouthed trap 'P' including case iron grating and fixed, including necessary excavation and earthwork, concrete in bed, surrounds, kerbs etc. and jointing to drains in CM 1:1 complete all as specified and as directed.
Demolition of cement concrete Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
S&F in repairs CI soil, waste and vent pipe in any length with or without ears, with cement joints, fixed to walls of 100 mm dia sand cast pipe complete all as specified and as directed.
S&F in repairs CI soil, waste and vent pipe in any length with or without ears, with cement joints, fixed to walls of 75 mm dia sand cast pipe complete all as specified and as directed.
M&L for 75 mm thick cement concrete type C-2, 1:3:6 (using 20 mm graded aggregate) as in plinth protections, to be finished even and smooth without using extra cement complete including use of necessary form work complete all as specified and as directed.
M&L for raking out joints, hacking for key, scrubbing down with water of joints of brick/PCC tiles laid on flat on roof upto entire satisfaction of Engr-in-Charge and pointing with cement morater 1:3 mixed with water proofing compound to make joints fully water proof complete all as specified and as directed.
Cleaning of entire roof by scrubbing down with water including spouts of rain water pipe and cutting of trees, green vegitables, bushes including cutting of trunk n.exc 30cm girth and branches, digging out roots from roofs and making good the dismantled portion in cement mortar 1:3 mixed with water proofing compound complete all as specified and as directed. Notes:- a) The rate quoted by the tenderer are deemed to be included necessary T&P, cleaning of roof, cutting of trees, green vegitables, bushes etc and making good the surface with CM 1:3 with WPC and nothing extra shall be paid on this account. b) After completion of cleaning of roof, the contractor shall obtain the users signature (i.e. existing occupant) in a pucca bound register alongwith signature of JE/AGE and the same may be asked while claiming the payment on this account. c) The said work caters for the following blocks/buildings:- Block No/Bldg No. P-7 to P-10, P-55, P-64, P-65, P-85 to P-104, M-01, P-64, P-65, P-66, P-67, P-68, P-69, P-70, P-71, P-72, P-106, P-107, P-108, P-109, P-120, P-122, P123.
S&F in repairs framed work such as window grills, framed guard bars; barred iron doors for Mumty door, similar work conforming to Fe.290.Gde-E-165 and M&L including two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
S&F in repairs 2 mm thick mild steel sheet as in Mumty door including all welding complete with fixing arrangement including two coats of synthetic enamel painting over one coat of red oxide primer complete all as specified and as directed.
Cutting of trees on the external surfaces of wall including cutting of trunk n.exc 30cm girth and branches and digging out of up to four storied bldg and making good the dismantled portion in cement mortar 1:3 mixed with water proofing compound as per manufacturing instructions with match the existing surfaces of wall complete all as specified and as directed.
Demolition of old unserviceable existing RCC tank on top of roof of any description and in any position not otherwise specifically provided for height upto fourth storey of building including cutting of reinforcement as required to facilitate, demolition complete all as specified and as directed.
Note :- The contract sum shall be after deducting the amount of credit shown in Sch of Credit of this tender
A N BUILDERS
M/S Parmod Johar
JINDAL ENTERPRISES
VED PRAKASH ARORA
M/S Davinder Kumar
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .