Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical Qualified |
| 2 | Accepted-Technical 18 3 508 D 43 1 SHIVAGANGA NAGAR CHATRINAKA HYDERABAD HYDERABAD TELANGANA 500053 | HYDERABAD | TELANGANA | 500053 | Accepted-Technical Qualified |
| 3 | Accepted-Technical | Accepted-Technical Qualified |
| 4 | Accepted-Technical | Accepted-Technical Qualified |
| 5 | Rejected-Technical 110 ROYAL JIVDANI APT ACHOLE ROAD GALA NAGAR THANE MAHARASHTRA 401209 | PALGHAR | MAHARASHTRA | 401209 | Rejected-Technical Not meeting eligbility Criteria |
Tender Value
₹30 L
EMD Value
₹90,000
Closing Date
13 Aug 2026, 3:00 pmClosed
Sr. Purchase Officer
Plot No. 6 and 7, Hardware Park, Srisailam Highway, Hyderabad
Renovation of Existing Ladies Washroom located in Ground Floor, First Floor, Second Floor and Third Floor
2026_DIT_918773_1
CDACH/PUR/26/Washroom-HWP
Open Tender
Miscellaneous Works
Works
30 days
Hardware Park Campus
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,190
CDAC, Hyderaabd
₹90,000
Yes
16 Sept 2026
23 Jul 2026
14 Aug 2026
23 Jul 2026
13 Aug 2026
24 Jul 2026
23 Jul 2026 - 12 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0 | Renovation Works -Renovation of Ladies Washrooms | - | - | - | - |
| 1 | Labour charges for removal of existing tiled flooring and tiled dadooing from walls including cost and conveyance of all materials ,labour charges and stacking carefully the material for disposal.etc complete. | 2,500 | sft | - | - |
| 2 | Removal of cinder concrete from sunken slabs to a depth of more than 15cm thickness and stocking for disposal.etc complete. | 380 | cft | - | - |
| 3 | SUNKEN PORTIONS WATER PROOFING
Pre Treatment Step:
1) Cleaning and water jetting the entire area.
Porosity Reduction
1) Spraying of protekh base which fills the fine pores with crystalline silicate growth.
Defect Removal:
1) Sealing of cracks , voids floor wall junctions etc.,with protekta sealant 500 modified mortar.
Surface Preparation :
1) Packing of areas alround down taken pipes with protekta sealant 500 modified mortar
2) Brush coat of alastomeric coating protekta flex joint only on the floor wall junction/cracks/areas around down take pipes.
Slope making :
1) Brush application of protekta special slurry which has very special chemical , which impregnates through pores and capillaries. This treatment continues upto 300mm of wall height.
2) Lying of cement concrete (1:2:4) proposition with 6-12mm size HBG metal mixed special admixture protekta KR2 125ml/bag of cement.
Curing –cum-testing for 10 days
Water proofing:
1) spraying of crystallization product protekta base.
2) Brush coat of protekta top seal coat as abrasion & water resistant layer. | 750 | sft | - | - |
| 4 | Providing and laying cinder concrete in cement cinder mix (1:15) proportion using 12.5mm nominal size cinder laid in layers and compacted as directed for filling sunken floors including cost and conveyance of all materials, water to work site seignorage charges and all operational, incidental, labour charges, such as mixing cement & cinder etc., complete for finished item of work. | 350 | cft | - | - |
| 5 | Laying of Plain Cement concrete work of mix (1:2:4) Using 20mm to 10mm guage hard granite machine crushed metal including cost and conveyance of all materials, labour charges, etc., Complete for finished item of work. | 150 | cft | - | - |
| 6 | Supply and fixing of 110 mm dia 3m long double socket PVC/SWR pipe-4Kgs/Sqcm Ashirvad/Prince/Sudhakar make or any ISI brand etc.., complete. | 250 | rft | - | - |
| 7 | Supplying and fixing 90mm Dia 3m single socket PVC/SWR pipe-4 Kg / sqcm (Prince / sudhakar / supreme or ISI brand) etc…, complete. | 250 | rft | - | - |
| 8 | Supply and fixing of ashirwad /ajay/astran/flow guard or equivalent CPVC pipe and fittings to meet requirement of ASTM-D 2846 and or produced in CTS(copper tube size) 3/4” ashirwad flow guards SDR11 pipes are made from identical CPVC compounds having physical properties for hot and cold water ISI 5778 of 2007 for following diameter. | 120 | rft | - | - |
| 9 | Supply and fixing of ashirwad /ajay/astran/flow guard or equivalent CPVC pipe and fittings to meet requirement of ASTM-D 2846 and or produced in CTS(copper tube size) 1 1/2” ashirwad flow guards SDR11 pipes are made from identical CPVC compounds having physical properties for hot and cold water ISI 5778 of 2007 for following diameter. | 170 | rft | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.00 MB
WashroomRenovation.pdf
Tender Documents • 1.56 MB
BOQ_965532.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .