Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.1 LAccepted-Finance | L1 | Accepted-Finance LOWEST BIDDER | |
| 2 | L2₹37.4 L+₹1.3 L (3.61%)Rejected-Finance B 22 152 STREET NO 1 14 BABA FARID NAGAR BATHINDA 151001 PB | BATHINDA | PUNJAB | 151001 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹37.5 L+₹1.4 L (3.90%)Rejected-Finance NO 943 0 56 VILL PO PATHRERI TEH KOTPUTLI DIST JAIPUR RAJASTHAN 303 107 | JAIPUR | RAJASTHAN | 303107 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹39.0 L+₹2.9 L (8.11%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹46.5 L+₹10.5 L (29.0%)Rejected-Finance PLOT NO 46 WARD NO 08 OPPOSITE RADIO TOWER SAGAR ROAD TILAK NAGAR BIKANER 334003 RAJ | BIKANER | BIKANER | RAJASTHAN | 334003 | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
11 Nov 2021, 6:00 pmClosed
GE North Bikaner
GE North Bikaner
REPAIR MAINT CLEANING OF SEWAGE LINES SEPTIC TANKS SOAK WELLS MANHOLES CHAMBER REPAIR AND COVER OF OTM ACCN AND MD ACCN OF ZONE A VARIOUS UNITS UNDER AGE BR II AT MIL STN BIKANER
2021_MES_481957_1
GE (N) BKN TOKEN NO 57/2021-2022
Open Tender
Civil Works
Item Rate
330 days
BIKANER
Class D category a i
8 documents required · 8 mandatory
₹500
GE North Bikaner
₹98,000
Yes
6 Dec 2021
14 Oct 2021
13 Nov 2021
14 Oct 2021
11 Nov 2021
28 Oct 2021
Amount
Note for Item No 01 & 02 :-The contractor / his rep will collect the complaint from complaint cell every day at 9.00 AM and rectify the complaints same day and deposit the complaint slip ( duly signed by the users ) to concerned JE. If the contractor fails to rectify the defects mentioned in the complaint (Job) on same day, he will be charged Rs. 50/- per Job/per day and same will be recovered from his RAR . Cleaning/removing blockage of EWC, IWC, Gully Trap, including P or S Traps of any description, by rodding, by pressure pumps of any description or by other mechanical equipments in any position or locations at Military station Bikaner under AGE B/R-II area till complete satisfaction of Engr-in-Charge.
Cleaning/removing blockage of floor trap, nahni trap, wash basins, sinks etc including waste pipe or waist coupling etc. by manually or mechanically at Military station Bikaner under AGE B/R-II area till complete satisfaction of Engr-in-Charge.
Cleaning/removing blockage sludge of sewer line (SGSW/RCC/CI) of dia 100/150/200/300mm etc of any description or in any position by roding, by pressure pump of any type or by using any mechanical equipments, manually or by puncher of sewage`line and repair the same if required including taking off and refixing manhole covers including removing all sludge in or outside MD land complete all as specified and directed by Engr-in-Charge.
De-watering from septic tanks/soakage wells by suitable pumps and also removing of all wastes, semi solid or liquid of any description to the location as specified and directed by Engr-in Charge. (note: dewatering tank will be taken to the STP location shown by Engr-in Charge.)
De-sludging by removing of semi solid sludge from existing septic tanks of any depth, any capacity in foul condition, including taking and placing in position the manhole cover of any description, removal of sludge & solid content to any place outside defence land and deposting where directed by Engineer-in-Charge.
De-sludging the existing / cleaning of man holes of depth not exceeding 2 mtrs of any size by removing silt/grit/sludge and faul water either by mannual or by mechanical means and flushing water through man holes to ensure free flow of sewage, placing back the man holes covers in position including removal all the sludge/silt/any foreign material from the sewer lines out the defence land complete all as specified and directed by Engineer-in-Charge.
All as per item srl No 6 here-in-before but depth exceeding 2 mtr (NOTE for srl item no. 03,06 and 07:- sewage line/ Manholes in item no. 03, 06 and 07 cleaned once will not be paid again within 06 months if blockage come within 06 months & contractor shall have to clear/ remove blockage at his own cost).
Excavation in trenches in soft/loose soil not exceeding 1.5 m wide and not exceeding 1.5 m deep in foundations or for walls of manholes etc not exc 10 sqm on plan and not exceeding 1.5 m in depth and getting out complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, soft/loose soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed by Engineer-in-Charge
Demolition of cement concrete haunching without bedding layer to drain pipes including drain pipes etc complete against the side of the pipe &removing all retrieved material all as directed by Engr-in-Charge.
M&L Plain Cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate as in packing under and hunching against the sides of pipes, without bedding layer, after they are laid and tested in 150 mm dia of pipe complete all as specified
M&L Salt glazed stone were drain pipes, class SP3 ,150 mm bore (internal dia) laid in trenches over existing concrete bedding and jointed as specified
Supplying and laying in repairs 100mm bore cast iron soil, waste and vent pipe in any length , sand cast pipe with and without ears (conforming to IS-1729 of 2002 second revision , laid under floors trenches with cement joints complete all as specified and as directed by Engr-in-Charge.
Demolition of brickwork built in cement or cement lime mortar complete all as psecified and as directed by Engr-in-Charge.
M&L for Brick work with fly ash bricks old size straight or curved on plan exceeding 6m mean radius built in CM 1:6 complete all as specified and as directed by Engr-In-Charge.
All as per serial item No. 16 here-in-before but using old bricks and directed by Engineer-in-Charge.
Taking down cement plaster/terrazo finish on brick or stone walll etc including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed
M&L 15mm thick cement plaster in cement and sand mortar 1:4 using water proofing compound as per manufacturer’s instructions on brick or concrete surfaces (surfaces fair or other than fair) including finishing the surfaces even & smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge.
Supply only liquid water proofing compound ISI marked.
M&L PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in surface channels and drains etc inside the manholes complete all as specified and directed by Engineer-in-Charge.
M&L plain Cement concrete type D-2 1:4:8 using 40 mm graded stone aggregate) in foundation, filling and mass concrete
Demoliton of stone slab as in roofs , suspended floors any thickness jointed in any mortar complete all as specified and as directed by Engineer-in-Charge.
M&L Jodhpur stone of roof slab self faced ,7.5cm to 10 cm thick ,25 cm to 35cm wide ,hoisted and set ,jointed and grouted in cement and sand mortar (1:6) complete all as specified
M&L 50mm thick P.C.C 1:3:6 C2 using 40 mm graded stone agg. As in floors over stone patti roof slab finished the surface even and fair complete all as specified and as directed by Engineer-in-Charge.
Cutting into existing manholes or connecting new, drains making good existing benching or forming channel and reforming benching with cement and sand mortar 1:4 or PCC 1:2:4 type B-1 smooth finished and reforming benching as in 150 mm dia of pipe complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement Vitreous china squatting pan of orissa pattern, white of size 580x440mm with integral foot rest and P or S trap in cluding provision of lime concrete bedding min 150mm thick (1:2:5) inc taking out old WC complete.
S&F in repair Wash down water closet (Pedestal pattern), complete with PVC (SWR) 'P' trap 110mm dia including jointing with cement mortar to existing CI pipe line complete all as specified and as directed by Engineer- in - Charge.
S&F in repair Vitreous China bowl urinal (back and cornar wall type) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement flat back , size 465x355X265 mm white (minimum) with grating and union for discharge pipe ( excluding flushing cistern, flush pipe and waste pipe)
S&F in repair Vitreous China Urinal, Half stall type, white ( excluding flushing cistern, flush pipe and waste pipe)
Supply & fixing repairs plastic water closet seat cover, colour pattern with flat bottom and cover and mild steel chromium plated or aluminum hinging device.
M&L Pre cast reinforced cement concrete 1: 2 :4 using 20 mm graded stone aggregates as in manhole covers including removing old damaged cover from manhole complete all as specified and as directed by Engineer-in-Charge
M&L Mild steel TMT bars 10mm dia and over as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete.
M&L Plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in copings etc. including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete.
S&F in repairs Cast iron floor trap with grating including jointing to waste pipe in run lead, dia of outlet 100 mm, fixed in cement concrete 1:2:4 complete.
S&F in repairs Cast iron Nahani trap with grating including jointing to waste pipe in run lead, dia of outlet 100 mm, fixed in cement concrete 1:2:4 complete.
S&F in repairs Cast iron bends (any radius) with duck’s foot or heel rest, 100 mm bore with cement joints, fitted with oval access doors complete.
S&F in repairs Cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches,100 mm bore with cement joints complete.
S&F in repairs PVC (SWR) bends any radius, 110 mm bore complete.
S&F in repairs PVC (SWR) bends any radius, 75 mm bore complete.
S&F in repairs PVC (SWR) junction single, (single T) equal or unequal any radius, 110 mm bore complete.
S&F in repairs PVC (SWR) junction single, (single T) equal or unequal any radius, 75 mm bore complete.
Supply & fixing in repairs PVC (SWR) pipes 110 mm dia single socket in any length with rubber ring joints fixed to walls including MS clamps etc incl taking down unservicable pipe complete.
Supply & fixing in repairs PVC (SWR) pipes 75 mm dia single socket in any length with rubber ring joints fixed to walls including MS clamps etc incl taking down unservicable pipe complete.
S&F in repairs PVC (SWR) reducers 75-110 mm dia
S&F in repairs Stack clamps out of 50mm x 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof, for 100 mm bore pipes complete.
M&L Vitreous china wash basin, white, flat back, size 580 x 440mm, including brackets and cutting for and pinning in ends of brackets, fixed in repairs including 32mm bore brass chromium plated waste fitting and 32mm bore PVC waste pipe of sufficient length complete.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
M&L for coloured non skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match in floors etc including 15mm thick screed bed in CM 1:4
M&L Coloured Glazed ceramic tiles 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match in vertical surfaces including 15mm thick rendering in CM 1:4.
Demolition of cement concrete (un-reinforced of any description and in any position not otherwise specifically provided for all as directed by Engr-in-charge
M&L 15mm thick cement plaster in cement and sand mortar 1:3 using water proofing compound as per manufacturer’s instructions on brick or concrete surfaces (surfaces fair or other than fair) including finishing the surfaces even & smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge.
Applying evenly a tack coat of industrial bitumen 85/25, 1.2 kg/sqm incl cleaning surfaces
M&L for PCC 1:3:6 type C2 (using 40 mm graded stone/brick aggregate) as in lean concrete filling in sunken etc
HARPREET SINGH CONTRACTOR
vipul construction company
GURUJI ENTERPRISES
M/S BUDHRAM BISHNOI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .