| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹72.2 LAccepted-Finance | L1 | Accepted-Finance Lowest One | |
| 2 | L2₹76.5 L+₹4.3 L (5.92%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹77.2 L+₹5.0 L (6.90%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹80.0 L+₹7.8 L (10.8%)Rejected-Finance 1202 SAI PROVISO DHNISHT PLOT NO 72 73 SECTOR 20 KOPARKHAIRANE NAVI MUMBAI | THANE | MAHARASHTRA | 400601 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹81.0 L+₹8.8 L (12.1%)Rejected-Finance A 14 USHA SADAN NEAR POST OFFICE COLABA MUMBAI 05 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹1.9 L
Closing Date
25 May 2023, 6:00 pmClosed
GE NW NOFRA
Dr Homi Bhabha Road New Navy Nagar Colaba Mumbai
REPAIRS REPLACEMENT OF EM FITTINGS FIXTURES ALONGWITH LED LIGHTS UNDER CELL NO 1 AND OTHER CERTAIN MAINT WORK AT NOFRA AREA UNDER GE NW NOFRA COLABA MUMBAI
2023_MES_593490_1
8158
Open Tender
Civil Works
Item Rate
300 days
Mumbai
Please refer tender documents
8 documents required · 8 mandatory
₹1,000
GE NW NOFRA
₹1.9 L
Yes
17 Oct 2023
5 May 2023
27 May 2023
5 May 2023
25 May 2023
18 May 2023
5 May 2023 - 11 May 2023
Amount
Taking down carefully aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc to be measured separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified.
Material and Labour for point wiring complete with 1.5 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC non-metallic casing and caping of size not less than 25mm width, ISI marked with accessories fixed on wall/ceiling/truss etc with metallic ISI marked terminal boxes/ modular Cover plate concealed in wall including one FRLS PVC insulated & sheathed multistranded green colour copper conductor 1.5 sqmm as earth continuity conductor connected to common earth as earth dolly for :- Make of wire - Polycab / Finolex / Havells Make of casing caping - Pressfit / Precision
(a) One light point controlled by one switch SP one way.
(b) One ceiling fan point controlled with one 5A switch
(c) One exhaust fan point controlled with one 5A switch
(d) One 3 pin socket outlet 5Amps on independant board.
(e) One 3 pin socket outlet 5Amps on same board with other switches.
(f) One bell point controlled by one bell push 5 Amps.
Material and Labour for point wiring complete with 2.5 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC non-metallic casing and caping of size not less than 25mm width, ISI marked with accessories fixed on wall/ceiling/truss etc with metallic ISI marked terminal boxes / modular Cover plate concealed in wall including one FRLS PVC insulated & unsheathed multistranded green colour copper conductor 2.5 sqmm as earth continuity conductor connected to common earth as earth dolly. Make of wire - Polycab / Finolex / Havells Make of casing caping - Pressfit / Precision
Supply and fix in repair Modular Switch, 6Amp, One way, 1 module. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (Nixon)
Supply and fix in repair Modular blank plate, One way, 1 module. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (Nixon)
Supply and fix in repair Modular Switch, 16Amp, One way, 1 module. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (Nixon)
Supply and fix in repair Modular type bell push , 6Amp, 1 module. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (Nixon)
Supply and fix in repair Bell electric AC 230Volt single pole musical type with ISI mark. Make - Legrand /Gold Medal / Anchor
Supply and fix in repair Modular type, electronic fan regulator (5 step), 450 Watts, 230 volts, 2 module Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (Nixon)
Supply and fix in repair ceiling rose surface bakelite with ISI mark, flush type with ISI mark three terminals complete all as specified. Make - Legrand /Gold Medal / Anchor
Supply and fix in repair Modular Socket oulet, 6 Amps, 2/3 pin combined, 2 module. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (Nixon)
Supply and fix in repair Modular Socket oulet, 6/16 Amps, 2/3 pin combined, 2 module. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (Nixon)
M & L required for filling wall cavity & cutting chases in cement mortar 1:3 not exc 10 cm in girth to ends or edges including taking down existing metal or wooden sinking box & making good to wall surface for concealed modular metal flush box or concealed conduit wiring, etc
Supply and fix in repair Modular white cover plate with Frame 1 Module. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular white cover plate with Frame 2 Module. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular white cover plate with Frame 3 Module. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular white cover plate with Frame 4 Module. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular white cover plate with Frame 6 Module. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular white cover plate with Frame 8 Module. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular white cover plate with Frame 12 Module. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular metal flush box 1 module.
Supply and fix in repair Modular metal flush box 2 module.
Supply and fix in repair Modular metal flush box 3 module.
Supply and fix in repair Modular metal flush box 4 module.
Supply and fix in repair Modular metal flush box 6 module.
Supply and fix in repair Modular metal flush box 8 module.
Supply and fix in repair Modular metal flush box 12 module.
Supply and fix in repair Linear Aluminium Baten LED T/L 20W Aluminium Extruded Chanel Powder Coated with opaque diffuser for glare free light complete with accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified. Make- Philips / Havells/ Jaquar
Supply and fix in repair Linear Aluminium Baten LED T/L 20W Aluminium Extruded Chanel Powder Coated with opaque diffuser for glare free light (Warm White) complete with accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified. Make- Philips / Havells/ Jaquar
Supply and fix in repair Linear Aluminium Baten LED T/L 10W Aluminium Extruded Chanel Powder Coated with opaque diffuser for glare free light complete with accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified. Make- Philips / Havells/ Jaquar
Supply and fix in repair Linear Aluminium Baten LED T/L 10W Aluminium Extruded Chanel Powder Coated with opaque diffuser for glare free light (Warm White) complete with accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified. Make- Philips / Havells/ Jaquar
Supply and fix in repair Linear Aluminium Baten, inbuilt sensor based on smart LED auto dimmable from 100% of rated wattage to 30% on sensing of movement/occupancy, baten 20W Aluminium Extruded Chanel Powder Coated with opaque diffuser for glare free light complete with accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified. Make- CAT Part No. SZSLAMX020 - iSS of Shakti or equivalent in Philips / Havells/ Jaquar
Supply and fix in repair Linear Aluminium Baten, inbuilt sensor based on smart LED auto dimmable from 100% of rated wattage to 30% on sensing of movement/occupancy, baten 10W Aluminium Extruded Chanel Powder Coated with opaque diffuser for glare free light complete with accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified. Make- CAT Part No. SZSLAMX010 - iSS of Shakti or equivalent in Philips / Havells/ Jaquar
Supply and fix in repair LED lamp suitable for 14 watts, 240 volts, single phase, 50 Hzs, Lumen 1450 AC supply. Make- Philips / Havells/ Jaquar
Supply and fix in repair LED lamp suitable for 14 watts, 240 volts, single phase, 50 Hzs, Lumen 1450 AC supply (Warm White). Make- Philips / Havells/ Jaquar
Material and Labour in repair for Lamp holder, PVC /Polycarbonate type with cord grip cap suitable for pendant fittings complete all as directed by Engineer-in-Charge. Make- Anchor / Havells/ Legrand
Supply and fix in repair Plug and Socket enclosure, in sheet metal enclosure with MCB, SP 20 Amps 240 Volts complete with metal clad socket for window type air conditioners. Make - Legrand/ Schneider/ GE
Supply and fixing Recess Mounting LED panel, 2'x2', 34 Watt capacity, warm white, environmentlal friendly, new generation, ashthetically designed ultra modern, fully diffused, white powder coated, with polymer diffuser complete with acessories suitable for Armstrong/Grid Ceiling all as specified and directed . Make- CAT Part No. PLUTONEO2x2PLR34WLED857S of Havells or equivalent in Phillips / Jaquar
Supply and fixing Surface Mounting LED panel, 2'x2', 34 Watt capacity, warm white, environmentlal friendly, new generation, ashthetically designed ultra modern, fully diffused, white powder coated, with polymer diffuser complete with acessories suitable for surface all as specified and directed . Make- CAT Part No. PLUTOSURFACE2x2PLS34WLED840S of Havells or equivalent in Phillips / Jaquar
Supply and fixing Recess Mounting LED panel, 1'x1', 15 Watt capacity, warm white, environmentlal friendly, new generation, ashthetically designed ultra modern, fully diffused, white powder coated, with polymer diffuser complete with acessories suitable for Armstrong/Grid Ceiling all as specified and directed . Make- CAT Part No. PLUTO1x1PLR15WLED840/857S of Havells or equivalent in Phillips / Jaquar
Material & labour for unscrewing body parts of fans of any make/brands and description and opening of the stator & rotor of following sizes of fans and taking out down rod canopy,shackle, condeser housing with rubber reel bushes,ball bearing,metal bush and carry out repairs as directed and as required as under:- (a) M&L for opening the stator & rotor of the 1200mm / 1400 mm sweep ceiling fan cutting the exsisting worn winding & rewinding the fan with superior quality rewinding wire & filling the warnish as insulation between each winds & covering each loops of winding by sleeves & paper & reassembling of complete fan by fixing servicable old and new parts of fans i.e. rubber bush of condensor & shackle housing , condensor, gun metal bushes,ball bearings twin twisted copper cable down rod assembly with its shackle condenser housing & canopy ,split pins complete all as per manufacturers design air delivery including greasing,oiling & testing of fans all as per manufacturers design & speed complete all as directed & approved for 1200mm sweep. Notes for item NO (i) to (vii) :- (i). The quoted unit rate shall be deemed to be inclusive of taking out defective parts and fixing of new parts. All new parts shall be measured and paid vide relevant items of the schedule. (ii). The rates for refixing & taking out servicable parts shall be deemed to be included of quoted unit rates. (iii). New parts shall be of respective makes of fans. (iv). The quoted unit rates shall also include writing of MES No of fans (v). Unservicable /defective retrived parts shall be credited vide sch of creidt. (vi). After assembling all fans shall be tested for the speed as directed. (vii). All the fans are laying in store yard of AGE E/M and shall be repaired at store yard only.
All as per srl item No 42 here-in-before but for wall mounting fans/air circulation fans of any size
All as per srl item No 42 here-in-before but for Exhaust fans of 225/250mm/ 300 mm sweep
All as per srl item No 42 here-in-before but for Exhaust fans of 450 mm sweep
Supply & Fix in repair elctronic Fan regulator 400 watt step type heavy duty .Make: Havells,CG,Indo Asian
Supply and fix in repair GI U clamp heavy duty rubber reel of superior quality and nut and bolts with locking arrangement complete all as specified.
Supply only PVC canopy cover superior quality all as specified and directed by Engr - in - Charge
M&L for cleaning the fan motor assembly body,blade of ceiling fan, filling the cavity & painting with existing colour the ceiling fan/Exhaust fan with one coat of superior quality synthetic enamel paint by spraying appratus and spraying process including writing the MES number on the ceiling fans of 1200mm /1400 mm sweep with black colour synthetic enamel paint all as specified and as directed.
All as per srl item No 49 here-in-before but for wall mounting fan / air circulator of any size
All as per srl item No 49 here-in-before but for Exhaust fans of 225/250mm/ 300 mm sweep
Supply only bearing No 6201 for 1200/1400mm sweep ceiling fans. Make NBC, SKF
Supply only bearing No 6202 for 1200/1400mm sweep ceiling fans. Make NBC, SKF
Supply only capacitor 2.5 MFD dry type.make: Amcap,Epscon
All as per Srl item No 54 here-in-before but 4 MFD. Make Amcap,Epscon
Supply only gun metal bush suitable for 1200/1400mm sweep ceiling fan.
S&F Clamp nut , bolt incliding safety pin for ceiling fan including taking down old pin.
Taking down old unserviceable rusted extaust fan shutter and supply and fixing shutter of size 225 to 450 mm sweep directed by engr- in- charge.
Making round/ square hole cutting in the kitchen wall with the help of cutting machine / chisel / hammer etc for fixing of exhaust fan of size 225 mm to 300 mm & making good to the distrubed surface including plaster, distumper , white wash complete all as specified and directed.
Checking serviceability of all ceiling fans/ exhaust fan in each quarter and checking clamps nut, bolts, pins are in healthy condition If any problem in any items will be noted down by electrician and informed concerned JE E/M and rectify the problem next day/ as soon as possible. All items will be measure and paid seperately all as directed by Engr -in-charge
Taking down old unserviceable submain cable of any size and capacity and finishing wall surfaces.
Supply and fix submain wiring in repair with two single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 4 Sqmm in and including PVC casing caping not less than 25mm width, ISI marked including 1 single core cable with stranded copper conductor of size 4 sqmm (green colour) for earthing. Note :- (i) Two runs of 4Sqmm cable, 1 run of PVC casing & caping and 1 run of 4 Sqmm cable shall be measured as 1 RM. (ii) Each submain wiring shall run in seperate PVC casing caping Make of wire - Polycab / Finolex / Havells Make of casing caping - Pressfit / Precision
Supply and fix in repair submain wiring two single core 6 Sqmm for sub main witing with copper conductor multistranded PVC insulated and unsheathed 1100Volts grade in and including PVC casing capping / conduit not less than 25mm dia with fixing accessories including one run of 6.0 Sqmm copper conductor. Note :- (i) Two runs of 06 Sqmm cable, one run of 6.0 Sqmm earth cable and one run of PVC casing Capping shall be measured as one running meter. (ii) Each submain wiring shall run in seperate PVC casing caping. Make of wire - Polycab / Finolex / Havells Make of casing caping - Pressfit / Precision
Supply and fix submain wiring in repair 2 single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 10 Sqmm in and including PVC casing caping / conduit not less than 25mm dia including 1 single core cable with stranded copper conductor of size 10 sqmm (green colour) for earthing. Note :- (i) Two runs of 10 Sqmm cable, 1 run of PVC casing caping/ conduit and 1 run of 10 Sqmm cable shall be measured as 1 RM. (ii) Each submain wiring shall run in seperate PVC casing caping / conduit Make of wire - Polycab / Finolex / Havells Make of casing caping - Pressfit / Precision
Supply and fix in repair sheet metal enclosure 12 way Double door type having protection IP-54, with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as directed of comprising of the following :- Make - Legrand/ Schneider/ GE
(a) MCB SPN 63 Amps, 240 Volts - 01 No Make - Legrand/ Schneider/ GE
(b) MCB SP 6-32 Amps, 240 Volts. Make - Legrand/ Schneider/ GE
Supply and fix in repair MCB, DB, SPN 8 way double door with protection type IP-54 with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as directed, as approved comprising following :- Make - Legrand/ Schneider/ GE
(a) MCB SPN 40 Amps 240 Volts. Make - Legrand/ Schneider/ GE
(b) MCB SP 6- 32 Amps 240 Volts, Make - Legrand/ Schneider/ GE
Supply and fix in repair single phase sheet metal powder coated double door distribution board 4 way comprising with following :- (a) MCB SPN 40Amps 240Volts, 10KA - 1 No (b) MCB SP 6 - 32Amps 240Volts - 2No Make - Legrand/ Schneider/ GE
Supply and fix in repairs sheet metal enclosure 2 way without bus bar with MCB comprising following Make - Legrand/ Schneider/ GE
(a) MCB SPN 63 Amps 240 Volts,. Make - Legrand/ Schneider/ GE
Supply & fix in repair MCB DB, TPN 8 way vertical type, 415 V with 200 Amps rated bus bar and double door connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as directed, comprising of the following : - (a) MCCB 3 Pole, 415 V fixed type, 160 Amps with breaking capacity 25 KA-01 Nos (incoming) MAKE: Legrand, Schneider, GE (b) MCB TP 63 Amps, 10KA - 06 Nos (Outgoing) MAKE: Legrand, Schneider, GE (c) MCB SP 40 Amps, 10KA - 06 Nos (Outgoing) MAKE: Legrand, Schneider, GE
S&F in repair switch socket combination multipurpose 2 in 1 for 3 pin 15 Amps & 3pin 5 Amp controlled by one switch flush type complete all as specified and directed. Make- Anchor / Legrand/ Goldmedal
Repairs and maintenance of water heaters (Geysers) at existing position of any capacity / size mounted on wall by opening nuts and locating the fault and repair / replacement of the unserviceable spares / parts and make it fully functional and reassembling the same after complete repairs in all respects all as specified and directed. Note:- Spare part shall be measured and paid separately under respective items.
Supply and fix in repair heating element 2KW /3KW, of instant type water heater as per existing capacity at site complete all as specified and directed.
Supply and fix in repair heating element 1KW/1.5KW, of storage type water heater 25 Ltr capacity at site complete all as specified and directed.
Supply and fix in repair thermostat / thermal cut out suitable for storage type water heater 25/50 Ltr capacity complete all as specified and directed.
Supply and fix in repair thermostat / thermal cut out suitable for instant type water heater 01 /06 Ltr capacity complete all as specified and directed.
Supply and fix in repair hot water extension pipe made out of copper chromium plated 450mm long with brass adaptor and fixing in position complete all as specified.
Supply and fix in repair 450mm long PVC connector with brass adaptor, washer and fixing in position complete all as specified.
Taking down and Supply & fix PVC cable multistranded insulated copper conductor 1100 volts grade of 4 sqmm 3 core, ISI marked complete all as specified and directed. Make- Polycab/ Havells/ finolex
Material and Labour for replacement of Inner tank made of SS 304 suitable for electric water heater capacity 25 Ltrs including PUF insulation for trap the heat in inner tank, high pressure withstanding enabling to use in high rise building complete all as specified by Engr-in-Charge.
Material and Labour for replacement of Outer body made of CRCA, colour- Ivory/white suitable for electric water heater capacity 25 Ltrs for multiple safety for dry heating & overheating complete all as specified by Engr-in-Charge.
Material and Labour for replacement of Inner tank made of SS 304 suitable for electric water heater capacity 06 Ltrs including PUF insulation for trap the heat in inner tank, high pressure withstanding enabling to use in high rise building complete all as specified by Engr-in-Charge.
Material and Labour for replacement of Outer body made of CRCA, colour- Ivory/white suitable for electric water heater capacity 06 Ltrs for multiple safety for dry heating & overheating complete all as specified by Engr-in-Charge.
Material and Labour for replacement of Inner tank made of SS 304 suitable for electric water heater capacity 01 Ltrs including PUF insulation for trap the heat in inner tank, high pressure withstanding enabling to use in high rise building complete all as specified by Engr-in-Charge.
Material and Labour for replacement of Outer body made of CRCA, colour- Ivory/white suitable for electric water heater capacity 01 Ltrs for multiple safety for dry heating & overheating complete all as specified by Engr-in-Charge.
Supply and fix MCB with MCB of 16/20 Amp, rating,IP 20 suitable for 240Volts including metal box 2P, IK 08 complete all as specified and directed by Engr-in-Charge. Make- Legrand/ ABB/ Schneider
Supply and fix in repair 15 Amps plug top, AC 230 volts, ISI marked. Make- Anchor/ Havells/ Legrand
M&L for cleaning the Geyser, filling the cavity & painting with existing colour with one coat of superior quality synthetic enamel paint by spraying appratus and spraying process including writing the MES number on the Geysers of any capacity with black colour synthetic enamel paint all as specified and as directed.
Checking serviceability of all Gesyers of any capacity in each quarter and checking clamps Anchors/Fasteners/nut/bolts/brackets are in healthy condition, If any problem in any items will be noted down by electrician and informed concerned JE E/M and rectify the problem next day/ as soon as possible. All items will be measure and paid seperately all as directed by Engr -in-charge
Supply Only Anchor Fasteners with Pins complete all as specified and directed by Engineer - in - Charge.
Supply Only Clamps of any size suitable for Geysers of capacity 6/25/50 Ltrs complete all as specified and directed by Engineer - in - Charge.
S & F GI Tube medium grade dia 15 mm dia concealed to walls for making water connection of Geysers all as specified and directed. Make: Tata/Jindal/Surya
S & F Stop valves, chromium plated, fancy type, castcopper alloy,screwed down,high pressure,with crutch orbutterfly handle, screwed bothends for ironpipe or for unions and fixed complete all as specified and directed by Engineer in Charge. Make: Jaquar/Prayag
S & F Bib Taps, cast copper alloy, chromium plated, Fancy Type screwed down,high pressure,with crutch or butterfly handle, screwed bothends for ironpipe or for unions and fixed complete all as specified and directed by Engineer in Charge. Make: Jaquar/Prayag
M & L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or burried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6 mm galvanised iron strip.
Earthing with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick, burried directely in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip32 x 6 mm with the help of bolts, nuts, and washers of galvanised iron or steel, including necessary excavation, PCC 1:3:6 type C2 and PCC cover 1:2:4 type B1 watering arrangement with GI pipe funnel, jali, complete all as specified and shown in electrical plate No. 5 of SSR Pt-1, including testing on completion.
ORIENT ELECTRIC CO
NOEL ENGINEERS
ASHOK ENTERPRISES
S S ENTERPRISES
BAJAJ CONSTRUCTION
SHREE JAGDISH FURNITURE CO.
C S Sharma and Co
AGRAWAL ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .