Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹68.7 LAccepted-Finance | ₹68.7 L | L1 | Accepted-Finance L1 |
| 2 | L2₹69.6 LRejected-Finance OLD NO 14 2 NEW NO 20 1 PARTHASARATHY STREET AYANAVARAM CHENNAI 600 023 | CHENNAI | CHENNAI | TAMIL NADU | 600023 | ₹69.6 L | L2 | Rejected-Finance L2 |
Tender Value
₹82.0 L
EMD Value
₹1.6 L
Closing Date
26 Feb 2026, 4:30 pmClosed
Regional Director (I/c)
ESIC Regional Office, Nungambakkam, Chennai 600034
ARM Electrical Works ESIC and ESIS Campuses at Tiruppur, Udumalpet and Pollachi for the period of 12 months.
2026_ESIC_897262_1
23/EE/PMD/ESIC/TN/ARM - E9/2026-2027
Open Tender
Electrical Works
Tiruppur
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹1.6 L
Chennai
6 Apr 2026
5 Feb 2026
27 Feb 2026
5 Feb 2026
26 Feb 2026
5 Feb 2026
12 Feb 2026
Engaging Substation attendant Cum DG Operator cum Panel opearator for day to day ( 3 shift /day) operation of Substation, DG sets, LT Panels , MCBs, MCB DBs, MCCBs, SFUs FSUs etc and all types of fans/ light fittings, UG cables etc complete all as directed by the Engineer-in-charge. and also Preventive maintenance of above mentioned equipment as per standerd check list and maintain logbooks along with shift register to be updated daily etc to be maintained as directed by engineer-incharge.. Skilled (ITI Certificate with 3 Years Experience)- 4 Nos. Note: 1. During Gen Shift, DG Opr cum Panel Board Operator can do the Electrical day to day complaints/maintenance work as per the direction of Engr-in-Charge.
Substation attendant Cum DG Operator cum Panel opearator-1
Substation attendant Cum DG Operator cum Panel opearator-2
Substation attendant Cum DG Operator cum Panel opearator-3
Substation attendant Cum DG Operator cum Panel opearator-4
Engaging Lift operator for day to day ( 2 shift /day) Lift Operator is responsible for the safe operation of elevators and lifts. Here are some common duties and tasks associated with this role: Loading and Unloading: Lift Operators assist passengers in safely loading and unloading ski lifts or other types of elevators. Safety and Comfort: They ensure the safety and comfort of passengers during lift operations. Maintenance: Operators maintain the lift area, keeping it clean and organized. They also implement emergency procedures when necessary. Evacuation: In case of disabled lifts or emergencies, Lift Operators evacuate passengers as per established protocols.[Supervision: Some operators supervise the lift operations ]-3 Nos (Semi-Skilled-2 Operators + 01 Reliever Nos ) ITI with 1 Year experience Operation & maintain of Lifts.
Lift opearator-1
Lift opearator-2
Lift opearator-3
Engaging a Fire Fighting Technician cum RO Plant, Water Suply Pump set operator, STP & ETP Plant operator for day to day (3 Shift/day) maintenance and operation of Fire pump house by operating of Diesel Engine,Jockey pump,Booster pump, presurization pump, terrace pump, diesel pumpmaintenance of fire panels and other equipments pertains to fire fighting system etc to maintain required water pressure at all times in External and internal fire hydrants, Hose reels etc complete all as directed by Engineer in charge. ( 4 Nos - Fire Fighting technician cum RO Plant operator (03 Operator + 01 Reliever)- skilled) (ITI Certificate with 3 Years Experience in Fire Safety).
Fire Fighting Technician cum Pump opearator-1 ( as detailed above)
Fire Fighting Technician cum Pump opearator-2 ( as detailed above)
Fire Fighting Technician cum Pump opearator-3 ( as detailed above)
Fire Fighting Technician cum Pump opearator-4 ( as detailed above)
Engaging an Electrician for day to day maintenance of Electrical works like repairs to internal and external electric supply by replacing the worne out fittings/fixtures , reparing the unserviceable fittings/ fixtures such as switches, sockets, switch boards, LT Panels , MCBs, MCB DBs, MCCBs, SFUs FSUs etc and all types of fans/ light fittings, OH lines, UG cables, DG Set etc complete all as directed by the Engineer-in-charge. (2 No's Electrician- Skilled for Hospital & Outstation campus) (ITI Certificate with 3 Years Experience).
Electrician-1
Electrician-2
Helper-1
Helper-2
Helper-3
Engaging of 1 No Charge Electricean having 'C' Licence Holder of day to day maintenance of Electrical maintenance works and to monitor these works are properly attended and to take care of complaints arised related to repairs / replacement of damaged fittings / fixtures in the campus such as switches, sockets, switch boards, HT/LT Panels , MCBs, MCB DBs, MCCBs, SFUs, FSUs etc., and all types of fans / light fittings, UG cables etc., complete all as directed by the Engineer-in-charge. ( 01 No.) (Qualification: Diploma in Electrical Engineering with 10 years related experience/ITI with 12 years or experience (supervisory) in maintenance job) (Qualification: ITI certificate with 03 years experience in operation of 11KV / 415V Substation and equipment and DG Sets along with valid 11KV /415V Supervisor permit /C- certificate/grade C-License Holder) (Higly Skilled). He is resposonsible to maintain & update the all logbook of preventive maintenace E&M equipment(Lifts,panels,Substation,DG sets,Fire equipment,RO,STP&ETP etc...) with respective staff.[1 No 'C' Licence Holder ( Highly Skilled)]. Note:- 1. He is the responsible for HT Metering cubicle to monitor & maintain all parameter readings. 2. He is the responsible for timely calibration of HT VCB's, LT ACB's/MCCBs and Earth Fault Relays and Over Current Relays. 3. He is the responsible for HT Panels, Transformers, ACBs, MCCBs, APFC Panels with connected Capacitor Banks, Power Contactors & Relays, Up Keep & maintain records for earth results in the HT & LT installations as per the direction of Engr-in-Charge. 4. During Main EB supply failure to monitor the running of stand by DG Sets and maintain the Plant Running Record Book with all parameters and Earth test Register & Insulation test register, fire alaram, smoke detection and fire fighting register all as directed. 5. To maintain the EB Shutdown Register & obtain the necessary signature from EB authorities . (It should be talley with Stand By DG Set PRRB)
Supply of 1.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
Supply of 2.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
Supply of 4.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
Supply of 6.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
Supply of 20 mm dia. ISI marked, PVC conduit (including elbow, reducer etc)
Supply of 25 mm dia. ISI marked, PVC conduit (including elbow, reducer etc)
Supply of 32 mm dia. ISI marked, PVC conduit (including elbow, reducer etc)
Supply of 20 mm PVC bends
Supply of 25 mm PVC bends
Supply of 32 mm PVC bends
Supply of 20 mm iron staples/ saddles/ screws
Supply of 25 mm iron staples/ saddles/ screws
Supply of 32 mm iron staples/ saddles/ screws
Supply of 20 mm PVC coupler/Junction box/Tee
Supply of 25 mm PVC coupler/Junction box/Tee
Supply of 32 mm PVC coupler/Junction box/Tee
Supply of S.P. 5/6 amps, one way modular switch, ISI marked
Supply of S.P. 5/6 amps, two way modular switch,ISI marked
Supply of S.P. 5/6 amps, one way modular switch, with "Fan" marking
Supply of S.P. 15/16 amps, one way modular switch, ISI marked
Supply of 3 pin 5/6 amps modular socket outlet, ISI marked
Supply of 6 pin 15/16 amps modular socket outlet, ISI marked
Supply of Modular bell push, ISI marked
Supply of Stepped type Modular Fan regulator (2 module)
Supply of Modular blanking plate
Supply of Call bell/ buzzer, single phase
Supply of PVC Batten/Angle Holder
Supply of Ceiling rose, 3 pin, 5 amps ISI marked
Supply of Modular PVC box for 2 module
Supply of Modular PVC box for 4module
Supply of Modular PVC box for 6 module
Supply of Modular base & cover plate for 2 module
Supply of Modular base & cover plate for 4 module
Supply of Modular base & cover plate for 6module
20/22 Watts 4 Feet LED Fitting with LED
Supply and fixing 7W / 9W LED Bulb
Supply and fixing 15W LED Bulb
LED 40 Watts 2'x2' Square type 4000K recessed litht fitting (HE)
LED 36 Watts 2'x2' Square type surface/recessed litht fitting (HE)
LED 12/15/18/22 Watts Round type recessed litht fitting (HE)
Supply and fixing 40W LED Street Light Fitting with LED
Supply and fixing 72W LED Street Light Fitting with LED
100W LED Flood Light Fitting with LED
150W LED Flood Light Fitting with LED
Suppy and Fix Timer Switch 24 Hours programmable switching time
Power Contactor 3 phase 4 pole, 63 Amps
Supply and fixing Water Tight Bulk Head Fitting suitable for 9-15 Watts LED Lamp with Guard Heavy Type
Supply & fixing of LED Driver as per IS 15885 (Part 2 / Sec13)..2012 including transportation with input line voltage 120V-270V AC, 50Hz with surge protection more than 2.5 KV, IP20, suitable for 12/15/18/20/22 W LED indoor luminaire, with 2 Years Warranty.Makes: As per list of recommended brands.
Supply & fixing of LED Driver as per IS 15885 (Part 2 / Sec13)..2012 including transportation with input line voltage 120V-270V AC, 50Hz with surge protection more than 2.5 KV, IP20, suitable for 36/40 W LED indoor luminaire, with 2 Years Warranty. Makes: As per list of recommended brands.
Supply & fixing of LED Driver as per IS 15885 (Part 2 / Sec13)..2012 including transportation with input line voltage 120V-270V AC & out put voltage 125V-160V 50Hz with surge protection more than 2.5 KV, IP20, suitable for 600 W LED outdoor signage board luminaire, with 2 Years Warranty. Makes: As per list of recommended brands.
Cable gland 10 Sqmm 2 core
Synthetic moulded Hensel/Syntex box for street light controls
Power Cpacitors of any type and model for power factor improvement, 3 phase 415 Volts
S&F Ceiling Fan of size 1200 mm , BLDC, BEE 5 star
S&F Wall Fan of size 450 mm
S&F Pedastal Fan of size 450 mm
S&F Modular Exhaust Fan of size 250 mm
AC Exhaust Fan of size 450 sweep Heavy Duty
Supply and fixing AC Exhaust Fan 300mm (12”) Sweep (Heavy Duty)
Supply and fixing MS / Fibre Louvers Shutters arrangements for 300mm AC Exhaust Fan
Supply and fixing MS / Fibre Louvers Shutters arrangements for 450mm AC Exhaust Fan
25 Amps motor starter 2 module (HE)
Hylem Sheet 3mm thick
PVC insulation tape
Empire tape
Cable route indicator (LT/HT) duly fixed.
MCB SP 6-32 Amps, 10 KA 'C' curve
MCB SPN 6-32 Amps, 10 KA 'C' curve
MCB TP 6-32 Amps, 10 KA 'C' curve
MCB TP 63 Amps, 10 KA 'C' curve
MCB TPN 6-32 Amps, 10 KA 'C' curve
Metal clad plug and socket 20Amps, 2 pole
Sheet Steel enclosure for MCB's 2 Pole
Sheet Steel enclosure for MCB's 4 Pole
RCCB 25 Amps, double pole
RCCB 63 Amps, four pole
MCCB 63/100 Amps, 3 Pole
Rotary Handle 63/100 Amps, for MCCB's.
MCCB 160 Amps 3 pole
Rotary Handle 160 Amps, for MCCB's.
MCCB 400 Amps, 50 KA, 4 pole
MCB DB TPN 4 way, IP-42
MCB DB TPN 8 way, IP-43
Digital Voltmeter 3 Phase
Digital Ammeter 3 Phase
Digital multifunctional meter
Cable termination for HT outdoor type XLPE suitable for 120-180Sqmm
Cable termination for HT outdoor type XLPE suitable for 240-300Sqmm
AC chargable emergency lamp
HT Rubber mat suitable for 11 KV 2 meter x 1 meter
First Aid box with all medicine
Shock treatment chart fixed in glass frame
Hand gloves 11 KV
Fire Extinguiser CO2 type
Earth discharge rod
1.5 TR Split type AC 5 Star rating
2 TR Split type AC 5 Star rating
Automatic Voltage Stabilizer 4 KVA
Automatic Voltage Stabilizer 5 KVA
S&F MS stand suitable for outdoor type split AC
Supply & Filling refrigerent gas R-410A
Supply & Fix 50 mm thick AVM pads.
Response indicator suitable for all type smoke/Heat detector located above false ceiling.
Multisensor (Heat cum smoke detector) suitable for addressible fire alaram system.
CT's of Ratio 100/5 set of 3
Mechanical interlock suitable for ACB's & VCB's
Power Plug & socket 16 Amps 200/250 Volts 2 pole + Earth
GI Plate earting of size 60x60cmx6 mm as per IS specification
Supply of Aluminium lugs for 16 sq. mm cable
Supply of 250 mm X 200 mm H.T. danger notice plate
Supply of 200 mm X 150 mm M.V. danger notice plate
Supply of Coke
Supply of Salt crystal
Supply of Industrial type pressure gauges with gun metal / brass valves
Supply of Industrial type thermometres mercury type
Supply and fixing Automatic Electrical Water Heater with copper container,with Glass Wool / Puf Insulation with MS powder coated shell suitable for 25 Litres capacity 230V / 1000W (Higher End)
Supply and fixing Surface Box [Supply and fixing SURFACE MOUNTING BOXES (PLASTIC) - HIGHER END] - 4 Module
Supply and fixing Surface Box [Supply and fixing SURFACE MOUNTING BOXES (PLASTIC) - HIGHER END] - 8 Module
Supply and fixing Surface Box [Supply and fixing SURFACE MOUNTING BOXES (PLASTIC) - HIGHER END] 8 (2 row x 4) Module
Supply and fixing 5 Amps 3 Pin Top
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Supply and transportation of 10Sq mm X 2 coreXLPE insulated, 1100V gradearmoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I U.G. CABLES Makes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt
Supply and transportation of 10Sq mm X 4 coreXLPE insulated, 1100V gradearmoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I U.G. CABLES Makes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt
Supply and transportation of 16 Sq mm X 4 core coreXLPE insulated, 1100V gradearmoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I U.G. CABLES Makes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt
Supply & Fixing cable jointing kit with cast resin compound with ferruls for suitable for 4 core 16 Sqmm upto 35 sqmm
Supply of 3 Core 2.5 Sqmm with ISI marked Flat Copper cable of ISI for Submersible Motors confirming to IS: 694:1990.Makes:Finolex/RRKabel/Polycab/Havells/KEI/ Gloster/ Goldmedal / GM/ Finecab/ Million/ APAR(Anushakthi)
Supply & Lowering vertical multistage 3 Phase submersible pump set with SS Shaft & CI body suitable for 120 LPM at 250 Mtrs head suitable for 7.5 HP all as directed. Makes: Kirloskar / Crompton / Texmo / CRI / KSB/Lubi/ PSG/ ARYEN VARSHA /Falcon/Prithvi
Supply & Lowering of Open well 3 Phase submersible pump set with SS Shaft & CI body suitable for 90 LPM at 24 Mtrs head suitable for 1.5 HP all as directed. Makes: Kirloskar / Crompton / Texmo / CRI / KSB/Lubi/ PSG/ ARYEN VARSHA /Falcon/Prithvi
Supply & Fix 20 mm Nylon rope grit clamping both side all as directed by the Engineer-in-Charge.
Supply of 155 X 210 X 92 Sizes thermo-plastic cable junction boxes with IP66/67 weatherproof, for outdoor installation with knockouts for cable entry including terminals etc., complete (sizes in mm). Make : Hensel/Sadhrish
Taking down the the unserviceable monoblock sewage sump set alongwith delivery pipes carefully from the STP & ETP of capacity 1.5 HP to 5 HP, 3 Phase and transport to workshop for repairs and after carryout the necessary repairs/rewinding etc…, and duly re-lowering the same after repairs all as directed by the Engineer-in-Charge.
Rewinding of 1.5 upto 5 H.P.- three phase motor of 1400 to 2800 RPM including all necessary material and of the same characteristics as original with required size of super enameled wire 'E' class insulation material including servicing of impellers, shafts and replacement of bearings etc..,and testing etc. as required make it in perfect working condition.
Taking down the the unserviceable Submersible Pump Set alongwith Column pipes carefully from the Bore well of capacity upto 7.5 HP, 3 Phase and transport to workshop for repairs and after carryout the necessary repairs/rewinding etc…, and duly re-lowering the same after repairs all as directed by the Engineer-in-Charge.
Rewinding & Servicing of Submersible Pump Set upto 7.5 H.P.- three phase motor of 1400 to 2800 RPM including all necessary material and of the same characteristics as original with required size of copper wound rewinding including servicing of impellers, shafts and replacement of bearings etc.., and as required make it in perfect working condition all as directed by the Engineer-in-Charge.
Rewinding of 7.5 HP upto 15.0 H.P.- three phase motor of 1400 to 2800 RPM including all necessary material and of the same characteristics as original with required size of super enameled wire 'E' class insulation material including servicing of impellers, shafts and replacement of bearings etc..,and testing etc. as required make it in perfect working condition.
Rewinding of ceiling fan motor (starting and running winding) including all necessary material. The motor is to be wound taking no. of coils, turns and pitch as it was originally wound with required size super enameled wire with 'E' class insulation material including replacement of 2 Nos ball bearings of size 6201 &6203 and making connections etc. as required. (New model ceiling fan)
Servicing & Overhauling including greasing and Providing and Replacement of ball bearing of ceiling fan, table fan, pedestal fan, exhaust fan irrespective to the size of fan including replacement of ball bearing of size 6201,6202,6203 &6204 all as required at site . (NBC/ SKF)
Supply & fix PCB board assembly suitable for BLDC ceiling fan of size 1200 mm sweep Make: Orient
Rewinding of Heavy-duty Exhaust fan motor of size upto 450 mm sweep including all necessary material, The motor is to be wound taking no. of coils, turns and pitch as it was originally wound with required size super enameled wire with 'E' class insulation material and making connections etc. as required.
Supply and fixing of 230V/ 275V, 50Hz rating of 20-60 micro farad.Starting capacitor
Supply and fixing of 230V/ 275V, 50Hz rating of 80-150 micro farad.Starting capacitor
Supply and fixing Supply and fixing of water drain pipe line (1” PVC Pipe)
Supply and fixing Supply and providing of pipeline nitrle rubber insulation for Refrigerant and drain pipe lines
Supply and fixing 6 Metre Length Single Bracket Pole with Base Plate (250 x 250 x 6mm) 76.10mm OD x 3.65mm Thick x 6000mm Length
Supply and fixing 6 Metre Length Double Bracket Pole with Base Plate (250 x 250 x 6mm) 76.10mm OD x 3.65mm Thick x 6000mm Length
Air filter suitable for 1/1.50/2 Ton Split A.C. Unit P.V.C. / NYLON if required at site all as directed by the Engr-in-Charge
Repairs and Installation of existing PCB in 1.0 / 1.5 / 2.0 Ton Split A.C. Unit if required at site all as directed by the Engr-in-Charge
Servicing the Split type 1.5/2.0 Ton AC unit by taking down the indoor and outdoor units by pumpdown the refrigerent gas & Overhauling and servicing the Split type 1/1.5/2.0 Ton AC unit by Cleaning through the water jet pump with condenser cooling Coil etc., by blower and oiling the Fan Motor for the indoor and outdoor units and Cleaning all parts and putting the machine in working condition and charging the refrigeranet gas if required basis only at site all as directed by the Engr-in-Charge. (Note :1. If requirement of refrigerent gas is essential basis will be measured and paid under separate item. ie.for methodology by weighing the gas cylinder before and after charging for how much gas have been charged. 2. Otherwise servicing only accounted for this item).
Fabrication, Transportation and supply of 1.0 Mtr Length Single Arm Bracket made with MS galvanized 40mm / 50mm dia Pipe. (The design should be approved from field Engineers)POLE BRACKETS
Supply and Fixing of 240/220 V, LED (22.5 mm dia) Pilot lamp with integral circuit, terminal block, including connection etc. as required : Red/yellow/Green colour
Supply and fixing of push button actuators and integral contact block of dia. 22.5 mm including making connection etc. as required. Make:Seimens/ ABB/ Schneider/L&T/C&S/HPL : Non-luminous type
Routine maintenance of transformer including testing of insulation resistance, oil breakdown strength. Reconditioning / replacement of silica zel, cleaning of transformer and topping upto oil level if required (extra cost will be paid for oil).
Testing of Transformer oil for dielectric breakdown strength duly tested from the authorised agency/dealer.
Testing of Transformer oil for Acidity analysis strength test report duly tested from the authorised agency/dealer.
Supply of new and tested transformer oil as per IS- 335 - 1972 (per Ltr)
Filtration and de-hydration of transformer oil as per ISS specifications filters to dielectric strength above 40KV …….at site. (Per Ltr)
Supply and replace the slica gel in the transformer breather all as directed.
Supply and fixing of 12V 180 AH SMF battery with 3 years warranty, including wire leads, connections etc complete. Makes: Quanta / Racket / Exide.
Supply and fixing of 12V 18 AH SMF battery with 3 years warranty, including wire leads, connections etc complete. Makes: Quanta / Racket / Exide.
Supply and fixing of 12V 9 AH SMF battery with 3 years warranty, including wire leads, connections etc complete. Makes: Quanta / Racket / Exide.
Supply and fixing of 12V 120 AH SMF battery with 3 years warranty, including wire leads, connections etc complete. Makes: Quanta / Racket / Exide.
Supply and fixing of 12V 75 AH SMF battery with 3 years warranty, including wire leads, connections etc complete. Makes: Quanta / Racket / Exide.
Supply and fixing of 12" Cabin Fan including wirring and connections etc complete.Makes: Almonard/Reni
Servicing and Testing of HT 11 KV VCB Panel from the authorised OEM/Agency/dealer and obtain the necessary testing and service report all as specified and as directed by the Engr-in-Charge.Make-Schneider
Servicing and Testing of LT ACB of 1250 Amps rating Panel from the authorised OEM/Agency/dealer and obtain the necessary testing and service report all as specified and as directed by the Engr-in-Charge.
Servicing and Testing of LT ACB of 800 Amps rating Panel from the authorised OEM/Agency/dealer and obtain the necessary testing and service report all as specified and as directed by the Engr-in-Charge.
Servicing, Testing and Calibration of Differential type Relays, Auxiliary Relays, Trip Circuit Supervision Relays and Master Trip Relays and all connected items in the Power House HT/LT Panels Panel Board with repairs/replacement of any spares required at site from the authorised OEM/Agency/dealer and obtain the necessary calibration certificate and all as directed by the Engr-in-Charge.
Servicing, Testing and Calibration of Earth Fault Relays, Over Current Relays, and all connected items in the Power House HT/LT Panels Panel Board with repairs/replacement of any spares required at site from the authorised OEM/Agency/dealer and obtain the necessary calibration certificate and all as directed by the Engr-in-Charge.
6 Way SPN Double Door MCB DB
8 Way SPN Double Door MCB DB
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Earthing with G.I. earth plate 600mmx600mmx6 mm including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required and all as directed by the Engr-in-Charge.
Earthing with Copper earth plate 600mmx600mmx3 mm including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required and all as directed by the Engr-in-Charge.
Supplying and laying 25x5mm thick GI earth strip at 0.50 meter below ground level as searth electrode, including connection/terminating with nut, bolt, spring, washer etc as required with 2 sets of GI nut bolt & spring washer spaced at 50 mm and all as directed by the Engr-in-Charge.
Supplying and laying 25x3mm thick copper earth strip at 0.50 meter below ground level as searth electrode, including connection/terminating with nut, bolt, spring, washer etc as required with 2 sets of brass nut bolt & spring washer spaced at 50 mm and all as directed by the Engr-in-Charge.
Supply and fixing of DOL Starter in sheet steel enclosure type MN/ML, AC , 3 Phase, 415 Volts, 50 Hz suitable for Upto 10 HP Motor all as required at site and as directed by the Engr-in-Charge.
Supply and fixing of Fully automatic Star Delta Starter in sheet steel enclosure type MN/ML, AC , 3 Phase, 415 Volts, 50 Hz suitable for Upto 17.5 HP Motor all as required at site and as directed by the Engr-in-Charge.
Supply and mix DAP (diammonium Phosphate) in the STP and ETP all as required at site and as directed by the Engr-in-Charge.
Supply and mix Urea industrial grade in the STP and ETP all as required at site and as directed by the Engr-in-Charge.
Supply and mix Sodium Hypo Chlorite Solution in the STP and ETP all as required at site and as directed by the Engr-in-Charge.
Supply and mix Hydrated Lime Chemical Solution in the STP and ETP all as required at site and as directed by the Engr-in-Charge.
Supply and mix Industrial grade Alum Chemical Solution in the STP and ETP all as required at site and as directed by the Engr-in-Charge.
Supply and mix Bleaching Powder in the STP and ETP all as required at site and as directed by the Engr-in-Charge.
Servicing and cleaning of existing Smoke detector and fire alarm system to made fully functional the visual indication, monitoring system including connections, interconnections and made functional for the locking arrangements with key including proper checking for loop connections and fixing new batteries as required at site etc all as directed by the Engr-in-Charge. Note:- Batteries will be measured and paid under separate items.
Servicing of Sluice valve/Butterfly Valve of size 80/100/150/200 including necessary rubber gasket if required replacement of bolts&nuts all as directed by the Engr-in-Charge.
Servicing of 'Y' type strainers of size 80/100/150/200 including necessary rubber gasket if required replacement of Steel mesh and bolts&nuts all as directed by the Engr-in-Charge.
Supply and Fix NRV of size 150 mm replacement of bolts&nuts all as directed by the Engr-in-Charge.
Supply & Fix pressure differential switch Make-Danfoss
Supply and Fix 15 mm dia pendent Sprinkler of 68 degree celcius standard response and standard coverage all as directed by the Engr-in-Charge.
Supply and Fix pressure gauge in MS pipe line with nipple including all connections with siphon all as directed by the Engr-in-Charge.
Supply & Fix rubber gasket 3 mm thick
Cotton Waste/ Cleaning cloth
Supply & Fix 3 Pole Power Contactor of size MNX 18 Make : L&T
Supply & Fix 3 Pole Power Contactor of size MNX 22 Make : L&T
Supply & Fix 3 Pole Power Contactor of size MNX 32 Make : L&T
Supply & Fix 3 Pole Power Contactor of size MNX 40 Make : L&T
Supply & Fix Spare Contact kit suitable for Power contactor MNX 18 Make : L&T
Supply & Fix Spare Contact kit suitable for Power contactor MNX 22 Make : L&T
Supply & Fix Spare Contact kit suitable for Power contactor MNX 32 Make : L&T
Supply & Fix Spare Contact kit suitable for Power contactor MNX 40 Make : L&T
Supply & Fix (Electronic Over Current Relay) Over Load Relay of capacity & range 9-45 Amps Make : L&T
Supply & Fix Electronic Timer of capacity & range 3-30 Sec Make : L&T
Supply & Fix Single Phase Preventor 415 volts, of model VSP D2 Make : Minilec
Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT
Refilling-6 Kg ABC Stored Pressure type Fire Extinguisher IS 2190 Incluing tranportation and Refixing in good condition as directed by Engineer In-charge
Refilling- 4.5Kg CO2type Fire Extinguisher as per IS 2190 Incluing tranportation and Refixing in good condition as directed by Engineer In-charge
Providing / conducting complete fire audit Including submission of fire audit report for the whole premises by Certified fire safety auditors / NABH-approved auditors / State Fire Dept (NOC) / Third-party expert agencies.
Water Heating element of capacity 3000 Watts suitable for solar water heater
Water Heating element of capacity 2000 Watts suitable for 25 Ltrs Geyser
Water Heating element of capacity 1500/1000 Watts suitable for 25 Ltrs Geyser
S&F Thermostate of capacity 0-75 degree celcius.
Supply & Fix Solar Water heater (Flat Plate type collector) of capacity 200 Litres Per Day including all connected items necessary structural works etc.., all as required at site and all as directed by the Engineer-in-Charge.
Supply & Fix MS/GI perforated cable tray painted with powder ocating of size 150x50x1.6 mm including connector, Tee and bend etc..,all as directed by the Engineer-in-Charge.
Supply & Laying HDPE pipe of size 63 mm including all fittings and all as required at site and all as directed by the Engineer-in-Charge.
Supply & Dressing Stone aggregate 40 mm of nominal size duly dressed up in and arround the HT Outdoor Substation yard all as directed by the Engineer-in-Charge.
Supply & Dressing coarse sand duly dressed up in and arround the HT Outdoor Substation yard all as directed by the Engineer-in-Charge.
Supply & Fix HT ariel fuse of size 5-30 Amps complete with porcelain tube all as directed by the Engineer-in-Charge.
Supply and Transportation of 0.5 HP Single phase Mono block CI body motor pumpset confirms to IS 9079:2002 including testing & commisioning of the same.Makes : Kirloskar / Crompton / Texmo / CRI / KSB/Lubi / Havells Hi-flow V2 / PSG/ ARYEN VARSHA /Falcon/Suguna
Supply and Transportation of 1 HP Single phase Mono block CI body motor pumpset confirms to IS 9079:2002 including testing & commisioning of the same.Makes : Kirloskar / Crompton / Texmo / CRI / KSB/Lubi / Havells Hi-flow V2 / PSG/ ARYEN VARSHA /Falcon /Suguna
SCHEDULE OF CREDIT ITEMS (TO BE ISSUED TO THE CONTRACTOR ON CREDIT)
Old unserviceable fans off sizes obtained from BOQ Item No.54 to 59 & 167
Old unserviceable Batteries off sizes obtained from BOQ Item No.162 to 166
Aluminium Scrap obtained from Old unserviceable aluminium wirings, lugs and aluminium Cables & connected items from BOQ Item Nos.35 to 44, 47 to 50, 87,88,111,116,117, 126 to 129, 144,145
Iron Scrap obtained from Old unserviceable items from BOQ Item Nos.11 to 13, 17 to 28, 51,66,108,110,140,148,149,191,192,193, 197 to 207
Copper Scrap obtained from Old unserviceable items from BOQ Item Nos.1 to 4, 45 to 46, 53,62,67 to 83, 98,99,105,118,136,138,139,140,143,180,181,211 to 215
PVC Scraps obtained from Old unserviceable items from BOQ Item Nos.5 to 10, 14 to 16, 29 to 34, 52, 119 to 121
Old used Transformer Oil obtained items from BOQ Item Nos.159
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
techsummary_943124.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.79 MB
BOQ_943124.xls
BOQ • 0.65 MB
Download all tender documents and submit your bid