Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.9 CrAccepted-AOC CHATRIBARI ROAD KRISHNA NAGAR GUWAHATI 1 ASSAM | KAMRUP METRO | ASSAM | 781001 | ₹6.9 Cr | L1 | Accepted-AOC Work Order Issued |
| 2 | L2₹7.3 Cr+₹34.6 L (5.00%)Rejected-AOC 1ST FLOOR 29A SESHAADHRI NILAY D NEOG PATH BEHIND DONA PLANET ANANDA NAGAR G S ROAD GUWAHATI ASSAM 781005 | KAMRUP METRO | ASSAM | 781005 | ₹7.3 Cr+₹34.6 L (5.00%) | L2 | Rejected-AOC L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Technically Non-Responsive |
| 4 | Rejected-Technical 14 BILASIPARA P O P S BILASIPARA DIST DHUBRI ASSAM PIN 783348 | DHUBRI | ASSAM | 783348 | - | - | Rejected-Technical Technically Non-Responsive |
Tender Value
₹5.3 Cr
EMD Value
₹10.6 L
Closing Date
7 Dec 2023, 2:00 pmClosed
CE, PWD(Bldg), Assam, Chandmari, Ghy-3
O/O The CE, PWD(Bldg), Assam, Chandmari, Ghy-3
Construction of ESS (Electrical Sub-Station) Block in Minister Colony, Dispur, Ghy-6
2023_PWBNH_34078_1
CE/TB-IV/45/2023/01 Dated Guwahati 3rd Nov 2023
Open Tender
Civil Works - Building
Item Rate
270 days
Dispur
Please refer Tender documents.
5 documents required · 5 mandatory
₹10,600
₹10.6 L
Yes
12 Aug 2024
20 Nov 2023
11 Dec 2023
20 Nov 2023
7 Dec 2023
28 Nov 2023
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials.All kinds of soil (From 1.5 to 3 m depth)
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
Providing and laying in position ready mixed or site batched design mix concrete for plain cement concrete work, using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland slag cement , admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength;' including pumping of concrete to site of laying, curing, carriage for all leads, but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge for the following grade of concrete. Note : Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content , the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Note : (1) Excess/less cement used than specified in this item is payable/ recoverable separately. (2) Fly ash conforming to grade I of IS 3812 (Part-1) only be used as part replacement of OPC as per IS : 456. Uniform blending with cement is to be ensured in accordance with clauses 5.2 and 5.2.1 of IS: 456 -2000 in the items of BMC and RMC." All works upto plinth level : Concrete of M10 grade with minimum cement content of 220 kg/cum
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Shelves (Cast in situ)
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Columns, Pillars, Piers, Abutments, Posts and Struts
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position ready mixed or site batched design mix concrete for reinforced cement concrete work, using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland slag cement , admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength;' including pumping of concrete to site of laying, curing, carriage for all leads, but excluding the cost of centering, shuttering , finishing and reinforcement as per direction of the engineer-in-charge for the following grade of concrete. Note : Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content , the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg/cum
Providing and laying in position ready mixed or site batched design mix concrete for reinforced cement concrete work, using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland slag cement , admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength;' including pumping of concrete to site of laying, curing, carriage for all leads, but excluding the cost of centering, shuttering , finishing and reinforcement as per direction of the engineer-in-charge for the following grade of concrete. Note : Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content , the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg/cum
Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: Cement Mortar 1:6 (1 cement : 6 coarse sand).
Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry with 150mm/230mm/300 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry 100 mm/ 125 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab upto 0.50 sqm
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of Slab over 0.50sqm
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.
Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick.
Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture Stainless Steel 304 grade CYLINDRICAL LOCKS - CLASSIC LOCK. Complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 300 mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 250mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00 mm thick with zinc coating not less than 275 gm/m²
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size Size of Tile 600x600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand)
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm.
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two or more coats on new work
Painting with synthetic enamel paint, having VOC (Volatile Organic Compound) content less than 150 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats.
Providing & fixing 150mm wide Chicken wire mesh on joints of RCC & Brick work before plastering complete in the direction of Engineer-in-charge.
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) : For fixed portion Powder coated aluminum (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). Powder coated aluminum (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Filling the gap in between aluminum frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.
Providing and fixing hand shower (Health faucet) with 1.2mtr long with 8mm dia Easy Flex Tube with wall hook and flow restrictor with flow rate 6 litre per minute at 3 bar in chrome finish and wall hook.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing & fixing toilet paper holder C.P. brass
Providing and fixing soil waste vent & rain water pipes 100 mm dia. Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
Providing and fixing M.S. holder-bat clamps of approved design to sand cast iron/ centrifugally cast iron(spun) pipes embedded in and including cement concrete blocks 10x 10 x 10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls, etc. For 100mm dia pipe
Providing and fixing bend of required degree with access door insertion rubber washer 3mm thick, bolts and nuts complete 100 mm dia Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing and fixing plain bend of required degree: 100 mm dia Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing and fixing trap of self cleansing design with sand cast iron screwed down or hinged grating with or without vent, arm complete, including cost of cutting and making good the walls and floors. 100mm inlet and 100mm outlet Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc. 15 mm nominal outer dia .Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia .Pipes.
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External Work 25mm nominal nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External Work 32mm nominal nominal bore
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25mm nominal bore
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixture and geyser points of approved quality confirming to IS: 8931.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S (non modular) bricks of class designation 7.5
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S (non modular) bricks of class designation 7.5
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete: 150 mm diameter
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: 150 mm diameter S.W. pipe
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610mm internal dimensiions total weight of cover and frame to be not less than 38 Kg. ( weight of cover 23 Kg. and weight of frame 15 Kg.), with FPS bricks with class designation 7.5 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2x1.5 sq mm + 1x1.5 sq mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2x6 sq mm + 1x6 sq mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 4x6 sq mm + 2x6 sq mm earth wire
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone Socket Outlet
Supplying and fixing following size/ modules, GI box along with modular base and cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm)
Supplying and fixing of following sizes of STEEL conduit alonwith the accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 20mm dia
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way Double Door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 Way (4+24), Double Door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 Amps
Design, Manufacturing, Supply, Receiving, Unloading, Shifting, installation, testing & commissioning of Outdoor type cubicle type totally enclosed free standing type moisture, dust and vermin proof made out of 2.0 mm thick & front cover 2.0 mm thick CRCA sheet complete with following equipments including internal wiring with suitable size wires / cable, interconnection, painting complete as per specification & drawing. All the incomming and outgoing MCCB shall have 25 KA Ics=Icu. All the MCCB up to 250 Amp shall have thermal release with adustable overload and short circuit protection and above shall have microprocessor release with adjustable overload, short circuit protection. Feeder pillae mounting MS Stand made out of 50mmx50mmx6mm Angle and all the civil work related to installation of Feeder piller shall be part of items. FEEDER PILLAR-1 INCOMING 1 No 400 Amp TP+N Moulded Case Circuit Breaker 1 Set of phase indicating lamps with Single Pole MCB. 1 Set of ON / OFF indicating lamps with Single Pole MCB. BUS BAR 500 Amp TPN aluminium bus bar. OUTGOING 04 Nos 160 Amp TP+N Moulded Case Circuit Breaker 1 Lot of control / power wiring. Feeder Pillar -1 described as above
Design, Manufacturing, Supply, Receiving, Unloading, Shifting, installation, testing & commissioning of Outdoor type cubicle type totally enclosed free standing type moisture, dust and vermin proof made out of 2.0 mm thick & front cover 2.0 mm thick CRCA sheet complete with following equipments including internal wiring with suitable size wires / cable, interconnection, painting complete as per specification & drawing. All the incomming and outgoing MCCB shall have 25 KA Ics=Icu. All the MCCB up to 250 Amp shall have thermal release with adustable overload and short circuit protection and above shall have microprocessor release with adjustable overload, short circuit protection. Feeder pillae mounting MS Stand made out of 50mmx50mmx6mm Angle and all the civil work related to installation of Feeder piller shall be part of items. FEEDER PILLAR-2 INCOMING 1 No 630 Amp TP+N Moulded Case Circuit Breaker 1 Set of phase indicating lamps with Single Pole MCB. 1 Set of ON / OFF indicating lamps with Single Pole MCB. BUS BAR 800 Amp TPN aluminium bus bar. OUTGOING 06 Nos 160 Amp TP+N Moulded Case Circuit Breaker 1 Lot of control / power wiring. Feeder Pillar -2 described as above
Design, Manufacturing, Supply, Receiving, Unloading, Shifting, installation, testing & commissioning of Outdoor type cubicle type totally enclosed free standing type moisture, dust and vermin proof made out of 2.0 mm thick & front cover 2.0 mm thick CRCA sheet complete with following equipments including internal wiring with suitable size wires / cable, interconnection, painting complete as per specification & drawing. All the incomming and outgoing MCCB shall have 25 KA Ics=Icu. All the MCCB up to 250 Amp shall have thermal release with adustable overload and short circuit protection and above shall have microprocessor release with adjustable overload, short circuit protection. Feeder pillae mounting MS Stand made out of 50mmx50mmx6mm Angle and all the civil work related to installation of Feeder piller shall be part of items. FEEDER PILLAR-3 INCOMING 1 No 400 Amp TP+N Moulded Case Circuit Breaker 1 Set of phase indicating lamps with Single Pole MCB. 1 Set of ON / OFF indicating lamps with Single Pole MCB. BUS BAR 500 Amp TPN aluminium bus bar. OUTGOING 05 Nos 160 Amp TP+N Moulded Case Circuit Breaker 1 Lot of control / power wiring. Feeder Pillar - 3 described as above
Design, Manufacturing, Supply, Receiving, Unloading, Shifting, installation, testing & commissioning of Outdoor type cubicle type totally enclosed free standing type moisture, dust and vermin proof made out of 2.0 mm thick & front cover 2.0 mm thick CRCA sheet complete with following equipments including internal wiring with suitable size wires / cable, interconnection, painting complete as per specification & drawing. All the incomming and outgoing MCCB shall have 25 KA Ics=Icu. All the MCCB up to 250 Amp shall have thermal release with adustable overload and short circuit protection and above shall have microprocessor release with adjustable overload, short circuit protection. Feeder pillae mounting MS Stand made out of 50mmx50mmx6mm Angle and all the civil work related to installation of Feeder piller shall be part of items. FEEDER PILLAR-4 INCOMING 1 No 400 Amp TP+N Moulded Case Circuit Breaker 1 Set of phase indicating lamps with Single Pole MCB. 1 Set of ON / OFF indicating lamps with Single Pole MCB. BUS BAR 500 Amp TPN aluminium bus bar. OUTGOING 05 Nos 160 Amp TP+N Moulded Case Circuit Breaker 1 Lot of control / power wiring. Feeder Pillar - 4 described as above
Design, Manufacturing, Supply, Receiving, Unloading, Shifting, installation, testing & commissioning of Outdoor type cubicle type totally enclosed free standing type moisture, dust and vermin proof made out of 2.0 mm thick & front cover 2.0 mm thick CRCA sheet complete with following equipments including internal wiring with suitable size wires / cable, interconnection, painting complete as per specification & drawing. All the incomming and outgoing MCCB shall have 25 KA Ics=Icu. All the MCCB up to 250 Amp shall have thermal release with adustable overload and short circuit protection and above shall have microprocessor release with adjustable overload, short circuit protection. Feeder pillar mounting MS Stand made out of 50mmx50mmx6mm Angle and all the civil work related to installation of Feeder piller shall be part of items. FEEDER PILLAR-5 INCOMING 1 No 630 Amp TP+N Moulded Case Circuit Breaker 1 Set of phase indicating lamps with Single Pole MCB. 1 Set of ON / OFF indicating lamps with Single Pole MCB. BUS BAR 800 Amp TPN aluminium bus bar. 05 Nos 160 Amp TP+N Moulded Case Circuit Breaker 01 Nos 100 Amp TP+N Moulded Case Circuit Breaker 1 Lot of control / power wiring. Feeder Pillar - 5 described as above
Supply and installation of 300 mm, 230 v A.C. exhaust fan in the existing opening including making good the damage, connection testing, commissioning etc as required.
Supply and installation of 400 mm, 230 v A.C.wall/cabin fan including fixing the bracket, making connection, testing, commissioning etc as required.
Supply, Installation, Testing & Commissioning of surface mounted Linear Batten 40W luminaire with high performance extruded aluminium channel housing for efficient heat dissipation.High efficiency long life LED package in integral module with system lumen efficacy of >100 lm/W and viewing angle of 120° to ensure better uniformity. Powered by an independent Isolated, SELV Output electronic LED driver with Output Short-circuit protection, Surge protection & other reliability test. Lumen Output of 4550 lumens.CRI >80, Color temperature 6500K, THD <10% and PF >0.95 ,IP20, IK03. Life class of 50,000 hrs @ L70, Operating Temperature:-10 TO +45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-60 HZ; Internal Surge Protection:3 KV;
Supplying and fixing single wall mounted 36 watt LED type batten fitting complete with electronic driver and LED tube etc directly on wall/ ceiling including connections with 1.5 sq.mm FR PVC insulated copper conductor and earthing the body etc. as required.
Supplying and fixing Surface mounted 70 watt LED High bay vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceiling including connection with 1.5 sq.mm FR PVC insulated copper conductor cable and earthing the body etc. as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 50 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
Design, Manufacture, Supply, Installation, Testing and Commissioning of Package Substation 500 KVA, 11 KV /0.415 KV, 3 phase, 50 Hz delta/star-11 connected, copper wound transformer, oil immersed ONAN cooled, RMU having 2 Load Break Switch + 1 Breaker on HT Side Busbar on LT Side only complete with all fittings such as oil conservator, silica gel breather, thermometer, explosion vent with On Load Tap changing (OLTC) arrangement on HV side with Tapping for variations of high voltage from (+) 5% to (-)15% in steps of 1.25% each with integrated microprocessor based RTCC Panel, bi-directional roller, diagrams & rating plate, Oil temperature indicator, & Winding temperature indicator, Buchholz relay, weather proof Marshalling Box, lifting lugs, first filling of oil, weather proof H.Tcable box & L.T Bus duct arrangement etc. complete as per specification. All relays, contacts & CT terminals to be wired upto marshalling box. Transformer losses shall be as per latest IS code 1180, Level-2.
Supply, Installation & Testing of following sizes MS exhaust piping conforming to IS:3589 complete with all accessories such as bends, flanges, 2 coat primer / painting etc. 250 mm dia MS pipe. (6.0 mm thick)
Supply & Fixing of Insulation of above pipe with 50 mm thick Loosely bound resin (LBR) mattress/ mineral wool/ Rockwool, density not less than 120 kg/m3 and aluminium cladding of 0.63 mm thick on exhaust pipe complete as per technical specification. 250 mm dia MS pipe.
Fabrication, supply & erection of MS structure for supporting of DG emission, exhaust piping with RCC foundation and in cable trench for cable support etc. complete in all respect.
Rubber mat 1000 mm. Wide to withstand 11 KV dielectric strength as per latest IS 15652-2006.
Supply & Laying of following sizes of 1.1KV grade multicore copper conductor PVC insulated and PVC sheathed armoured control cable conforming to IS:7098 (Part-I) 1988, including end termination with brass compression gland and copper lugs. 4 core, 1.5 sq.mm
Supply & Laying of following sizes of 1.1KV grade multicore copper conductor PVC insulated and PVC sheathed armoured control cable conforming to IS:7098 (Part-I) 1988, including end termination with brass compression gland and copper lugs. 8 core, 1.5 sq.mm
Supply & Laying of following sizes of 1.1KV grade multicore copper conductor PVC insulated and PVC sheathed armoured control cable conforming to IS:7098 (Part-I) 1988, including end termination with brass compression gland and copper lugs. 12 core, 1.5 sq.mm
Supply of following sizes of 1.1KV grade aluminium conductor XLPE insulated PVC sheathed (Heavy duty) armoured cable conforming to relevant IS. (Cable shall be purchased only after approval of cable schedule by architect / consultant). 3.5C x 25 Sq.mm
Supply of following sizes of 1.1KV grade aluminium conductor XLPE insulated PVC sheathed (Heavy duty) armoured cable conforming to relevant IS. (Cable shall be purchased only after approval of cable schedule by architect / consultant). 3.5C x 35 Sq.mm
Supply of following sizes of 1.1KV grade aluminium conductor XLPE insulated PVC sheathed (Heavy duty) armoured cable conforming to relevant IS. (Cable shall be purchased only after approval of cable schedule by architect / consultant).3.5C x 50 Sq.mm.
Supply of following sizes of 1.1KV grade aluminium conductor XLPE insulated PVC sheathed (Heavy duty) armoured cable conforming to relevant IS. (Cable shall be purchased only after approval of cable schedule by architect / consultant). 3.5C x 70 Sq.mm
Supply of following sizes of 1.1KV grade aluminium conductor XLPE insulated PVC sheathed (Heavy duty) armoured cable conforming to relevant IS. (Cable shall be purchased only after approval of cable schedule by architect / consultant). 3.5C x 95 Sq.mm.
Supply of following sizes of 1.1KV grade aluminium conductor XLPE insulated PVC sheathed (Heavy duty) armoured cable conforming to relevant IS. (Cable shall be purchased only after approval of cable schedule by architect / consultant). 3.5C x 120 Sq.mm.
Supply of following sizes of 1.1KV grade aluminium conductor XLPE insulated PVC sheathed (Heavy duty) armoured cable conforming to relevant IS. (Cable shall be purchased only after approval of cable schedule by architect / consultant). 3.5C x 150 Sq.mm.
Supply of following sizes of 1.1KV grade aluminium conductor XLPE insulated PVC sheathed (Heavy duty) armoured cable conforming to relevant IS. (Cable shall be purchased only after approval of cable schedule by architect / consultant). 3.5C x 185 Sq.mm.
Supply of following sizes of 1.1KV grade aluminium conductor XLPE insulated PVC sheathed (Heavy duty) armoured cable conforming to relevant IS. (Cable shall be purchased only after approval of cable schedule by architect / consultant). 3.5C x 240 Sq.mm.
Supply of following sizes of 1.1KV grade aluminium conductor XLPE insulated PVC sheathed (Heavy duty) armoured cable conforming to relevant IS. (Cable shall be purchased only after approval of cable schedule by architect / consultant). 3.5C x 300 Sq.mm.
Supply & making end termination with brass compression gland & aluminium lugs for following size of FRLS insulated and FRLS sheathed aluminium conductor cable of 1.1KV grade as required. 3.5 X 25 sq. mm (28mm) For aluminium armoured cable
Supply & making end termination with brass compression gland & aluminium lugs for following size of FRLS insulated and FRLS sheathed aluminium conductor cable of 1.1KV grade as required. 3.5 X 35 sq.mm (32 mm) For aluminium armoured cable
Supply & making end termination with brass compression gland & aluminium lugs for following size of FRLS insulated and FRLS sheathed aluminium conductor cable of 1.1KV grade as required. 3.5 X 50 sq.mm (35 mm) For aluminium armoured cable
Supply & making end termination with brass compression gland & aluminium lugs for following size of FRLS insulated and FRLS sheathed aluminium conductor cable of 1.1KV grade as required. 3½ X 70 sq. mm (38mm) For aluminium armoured cable
Supply & making end termination with brass compression gland & aluminium lugs for following size of FRLS insulated and FRLS sheathed aluminium conductor cable of 1.1KV grade as required. 3½ X 95 sq. mm (45mm) For aluminium armoured cable
Supply & making end termination with brass compression gland & aluminium lugs for following size of FRLS insulated and FRLS sheathed aluminium conductor cable of 1.1KV grade as required. 3½ X 120 sq. mm (45mm) For aluminium armoured cable
Supply & making end termination with brass compression gland & aluminium lugs for following size of FRLS insulated and FRLS sheathed aluminium conductor cable of 1.1KV grade as required. 3.5 X 150 sq.mm (50 mm) For aluminium armoured cable
Supply & making end termination with brass compression gland & aluminium lugs for following size of FRLS insulated and FRLS sheathed aluminium conductor cable of 1.1KV grade as required. 3½ X 185 sq. mm (57mm) For aluminium armoured cable
Supply & making end termination with brass compression gland & aluminium lugs for following size of FRLS insulated and FRLS sheathed aluminium conductor cable of 1.1KV grade as required. 3½ X 240 sq. mm (63mm) For aluminium armoured cable
Supply & making end termination with brass compression gland & aluminium lugs for following size of FRLS insulated and FRLS sheathed aluminium conductor cable of 1.1KV grade as required. 3½ X 300 sq. mm (70mm) For aluminium armoured cable
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Upto 35 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Above 35 sq. mm and upto 95 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Above 95 sq. mm and upto 185 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required. Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonary duct as required. Above 185 sq. mm and upto 400 sq. mm
11 KV H.T. CABLE: Supplying of 11 KV grade aluminium conductor, cross linked polyethylene (XLPE) insulated individual core screened, flat steel/strip armoured PVC sheathed cable complete as required. 3C x 120 Sqmm, 11 KV XLPE
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required. 120 sq. mm
HT CABLE LAYING: Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required. Above 120 sq. mm and upto 400 sq. mm
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel at least 2 mm thick, vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design : Inside dimensions 455x 610 mm and 45 cm deep for pipe line with three or more inlets. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design : Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth beyond 45 cm of brick masonry chamber For 455x610 mm size With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth beyond 45 cm of brick masonry chamber For 500x700 mm size With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.200 mm dia (OD-200 mm & ID-175 mm nominal)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.160 mm dia (OD-160 mm & ID-135 mm nominal)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 90 mm dia (OD-90 mm & ID-76 mm nominal)
Supply and erection of 7 metre height Hot-dip galvanized octagonal street light pole with following arm with top dia 70 mm and bottom dia A/F 155 mm, made of 3mm thick sheet along with base plate of size 260 X 260 X 16 mm , small door opening for junction box mounting with MCB & connector,cement,concrete of 1:3:6 including excavation, refilling and suitable size foundation bolts with template and all complete job as required. Single arm, 1500mm
Supplying and fixing 40/45 watt LED type street light with die cast aluminium housing for ingress protection of IP65 and complete with all accessories etc, on pole/building including connection with FR PVC insulated copper conductor cable and earthing the body etc. as required.
Supply of following sizes of 2/3/3.5 / 4 Core, 1.1KV grade aluminium conductor XLPE insulated PVC sheathed (Heavy duty) armoured cable conforming to relevant IS. 2.0Cx6 Sq.mm
Supply & making end termination with brass compression gland & bimettallic lugs for following size of FRLS insulated and sheathed aluminium conductor cable of 1.1KV grade as required. 2 X 6 sq. mm (25mm)
Shifting of existing equipments into new substation (Approximate Amount of Rs. 8,83,750.00)
Power Tools and Engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .