Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.0 LAccepted-AOC | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹27.7 L+₹2.3 L (8.91%)Rejected-Finance B XI 746 STREET NO 6 BHARAT NAGAR BARNALA 148101 | BARNALA | BARNALA | PUNJAB | 148101 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹29.8 L+₹4.3 L (17.0%)Rejected-Finance ASTBAL MOHALLA BANASAR BAGH ROAD PATIALA GATE SANGRUR 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹31.0 L+₹5.5 L (21.6%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹32.4 L+₹7.0 L (27.4%)Rejected-Finance 300 PREM BASTI 10 SANGRUR SANGRUR PUNJAB 148001 | SANGRUR | PUNJAB | 148001 | L5 | Rejected-Finance Being L5 |
Tender Value
Refer Docs
EMD Value
₹64,800
Closing Date
26 Sept 2023, 6:00 pmClosed
Sh Himanshu, IDSE
MILITARY ENGINEER SERVICES GARRISON ENGINEER SOUTH TARAPORE ENCLAVE PATIALA CANTT
As per tender documents
2023_MES_616548_1
GE(S)/PAT/T-38/N/2023-24
Open Tender
Civil Works
Item Rate
210 days
Mil Stn Nabha
Refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (South) Patiala
₹64,800
Yes
31 Oct 2023
31 Aug 2023
3 Oct 2023
31 Aug 2023
26 Sept 2023
13 Sept 2023
31 Aug 2023 - 6 Sept 2023
Amount
Taking down cement plaster on walls built in cement mortar etc including racking out joints, hacking for key Scrubbing down with water etc.all as specified and directed by Engr-in-charge
M & L for 15mm thick ( in two layers of 10mm and 5mm thickness) cement pastering in cement mortar 1:4 and mixig the water proofing compound as per manufactures instructions on brick or concrete surface of wall finished fair and even without using extra cement complete all as specified and directed by Engr-in-charge Note : Water proofing compound shall be measured and paid saparately .
M&L 10mm thick cement plastering in cement mortar CM 1:6 finishing the surface even and smooth without using extra cement complete all as specified and directed by Engr-in-charge
Complete removal of existing treatment of any type/description such as distempering work ,internal emulsion etc from internal/external surfaces of walls & ceiling with mechanical means/grinder including removal of material from site complete all as specified and directed by Engr-in-charge
M&L for applying acrylic thick wall care putty on internal/external surfaces of walls/soffits(thickness vary from1.5to2.5mm as required for desired smoothness and levelling of surfaces in two or more layers)by us ingready made wall careputty including sand papering after filling the putty to make surface smooth and ready for receiving painting etc complete all as specified and directed by Engr-in-charge
M&L Applying 02 coats of interior emulsion paint (white shade) @ 10 sq.m/litre/2 coats to wall surfaces over & including a coat of interior wall primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer of interior emulsion by using following brands of emulsion and primer complete all as specified and directed by Engr-in-charge
M&L Preparation of new plastered or unplastered surfaces of walls, two coats of cement base paint all as specified.
Supply only integral water proofing compound ISI marked. Make : Pidilite/Sika
M&L Rendering 5mm thick in cement mortar 1:3 as on concrete surfaces in ceiling finished even and smooth without using extra cement all as specified and directed by Engr-in-charge
M&L Preparation of new plastered or unplastered surfaces applying three coat of white wash on ceiling surfaces all as specified and directed by Engr-in-charge
M&L Preparing old plastered surfaces of ceilings and applying one coat of white wash in all as specified and directed by Engr-in-charge
Taking down chowkhats or frames (without taking off shutters from the frame) exc 1.5 Sqm and n. exc 4.00 Sqm incl cutting holes and making good reqd shape for hold fast block for new frame complete all as specified and directed by Engr-in-charge
All as per srl item No 12 hereinbefore but n. exc 1.5 sqm each.all as specified and directed by Engr-in-charge
S&F Powder coated Pressed steel frames made of MS sheet of 1.25 mm thickness for doors with double rebate including necessary fixing lugs, hinges, lock strike plate, hold fasts ,filling PCC (1:3:6 Co) in chowkhats , PCC 1:2:4 B1 hold fast blocks etc., complete as specified,size 125x 60mm including cutting holes and making good reqd to shape for hold fast blocks for new frame complete all as specified and directed by Engr-in-charge. ( Note :- Disturbed portion of existing floor /wall / tile / plaster etc duing fixing of chowkhats shall be repaired to match with existing finish .Cost of the same will be included in this item )
S&F 35mm thick plain framed (Factory made) Panelled shutters of 2nd class HW with lock rail and panels of 9mm B.W.P commercial ply including beading on the facing side of shutters as per SSR Part I clause No 8.17.5. The size of rail and stiles as per IS 1003 (Part I) kiln seasoned and chemically pressure treated all as specified and directed by Engr-in-charge
S&F 35mm Glazed and skeleton shutters, 2nd class hard wood open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats all as specified and directed by Engr-in-charge
S&F Mild steel barrel tower bolt 200mm long stove enamelled black with bright bolt and fixed all as specified and directed by Engr-in-charge
S&F Mild steel sliding door bolt of size 250mm , stove enamelled black with bright bolt not less than 16mm dia, with and including a minimum of 6 bolts and nuts, complete all as specified and directed by Engr-in-charge
S&F MS pressed handles of size 125mm oval type stove enamelled black.all as specified and directed by Engr-in-charge
S&F Mild steel butt hinges of size 100mm medium weight cold rolled.all as specified and directed by Engr-in-charge
S&F Mild steel butt hinges of size 50mm medium weight cold rolled.all as specified and directed by Engr-in-charge
S&F 300 mm long MS rat tail pattern spring hinge including roller and roller plate, complete all as specified and directed by Engr-in-charge
S&F Factory made steel windows box type using ERW hollow 'P' section comprising double frame for glaged and gauged skelton shutters jointed interally with flat iron 40x4mm complete including grill of 8mm square bar, fixed horrizontally @ 10cm centre to centre, hinges,handle tower bolts,lugs etc all as specified and directed by Engr-in-charge Note;- (i)for the purpose of measurement& payment double shuttre with frame shall be considered as one unit. (ii) Glaging ,, wire mesh and guard bars,shall be measured and paid for separately
S&F Steel ventilators fixed type with glazing bars complette all as specified and directed by Engr-in-charge.
Hacking out old broken glass (any thickness, size, quality or description from metal/wooden frame including punching or drilling out glazing pins/spring clips.all as specified and directed by Engr-in-charge
S&F Sheet glass ordinary quality 4 mm thick and glazing with oil puttly or wooden beads in square not exceeding 0.5 sqm in each pane complete all as specified and directed by Engr-in-charge
S&F in stainless steel wire cloth of 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanized wire staples or with wooden beads, screws and nuts botls etc. all as specified and directed by Engr-in-charge
M&L for preparing surfaces of any description over 10 cm girth or width, not otherwise described and applying two coats of synthetic enamel paint over a coat of Red oxide on new surfaces of steel or iron, complete all as specified and directed by Engr-in-charge
Demolition of cement concrete (un-reinforced) in ground floors and pavings n exc 15cm thickness (below or above ground level), complete all as specified and directed by Engr-in-charge
M&L 25mm thick PCC (1:2:4) type B-0 using 12.50 mm graded crushed stone aggregates in complete all as specified and directed by Engr-in-charge
Dismantling of floor or wall tiling including cement mortar bedding but not backing and removing the rubbish off the premises all as specified and directed by Engr-in-charge
M&L for Ceramic floor tiles of minimum size 600X600 mm 8 to 10mm thick in flooring etc set and jointed in neat cement lurry and pointed in white cement to match over and including 20mm thick screed bed in CM (1:4) laid over complete all as specified and directed by Engr-in-charge
M&L for anti skid coloured pressed ceramic floor tiles of minimum size 300X300 mm 8 to 10mm thick in flooring etc set and jointed in neat cement lurry and pointed in white cement to match over and including 20mm thick screed bed in CM (1:4) laid over in complete all as specified and directed by Engr-in-charge
M&L Coloured glazed ceramic tiles (300 x 600 mm) x 7mm or (450X350 mm)X7mm thick as in vertical surfaces such as skirtings, dados etc jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 10mm thick back coat in CM (1:4), in complete all as specified and directed by Engr-in-charge
Taking up or down steel tubing of size15mm bore and removal to store all as specified and directed by Engr-in-charge
Taking up or down steel tubing of size 20mm bore and removal to store all as specified and directed by Engr-in-charge
S&F medium grade galvanised steel tubing with all fittings fixed to wall or laid in floors for 20 mm bore GI tubing. all as specified and directed by Engr-in-charge
S&F medium grade galvanised steel tubing with all fittings fixed to wall or laid in floors for 15 mm bore GI tubing.all as specified and directed by Engr-in-charge
S&F chromium plated curtain rods 20 mm bore,1 mm wall thickness incl. brackets, stap rollerss fixed in repairs.all as specified and directed by Engr-in-charge
Taking out old damaged tar felt of any description from roof tops including cleaning and washing the surface and M&L for the following roof treatment. (a) 15 mm thick (average) cement screed in CM 1:4 on roof (tiled or concrete surfces) finishing even and fair all as specified. (b) Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3mm thick weight not less than 3.60kg/Sqm water proofing membrane, black finished reinforced with non woven polyester matt, fixed as per manufacturer’s instructions complete all as specified and directed. (c) Applying one coat of bituminous primer confirming to IS-3384 @ 0.3 Ltr/Sqm. (d) Applying one coat of aluminium paint over APP membrane @ 0.50 litres per Sqm all as specified and directed. (e) Applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg per square metre including cleaning the surfaces all as specified and directed by Engr-in-charge
Dismantling of asbestos cement sheets [corrugated, semi-corrugated, etc] in roof coverings complete all as specified and directed by Engr-in-charge
S & F for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/clading to wall, fixed to self tapping screws all as specified and directed by Engr-in-charge
S&F pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in ridges, roof covering/clading to wall, fixed with self tapping screws as specified.
Dismantling of wrought timber truss scantling 40Sq.cm and over in section framed work, provided for complete all as specified and directed by Engr-in-charge
Dismantling of wrought timber scantling as in fillets, post rafter , purlins etc under 40Sq.cm in section framed work, provided for complete all as specified and directed by Engr-in-charge
M&L for rectangle / Squar /circular hollow section as in main and cross beams, hip and jack rafters purlins, where connected to common rafters and running rails and guides for structural purpose, fixed with angle cleats or other connecting plates to Fe-290 (Gde E-165) all as specified and directed by Engr-in-charge
S&F mild steel plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases, splices, angle brackets, cleats and other connections complete all as specified and directed by Engr-in-charge
Demolition of brick work built in cement mortar.all as specified and directed by Engr-in-charge
M&L for brick work in cement mortar (1:6) using sub class 'B' bricks staight or curved on plan exc 6.0 m mean raidus all as specified and directed by Engr-in-charge
S&F 30mm thick PVC door factory made solid panell shutters concisting of frame made out of MS tubes for top and bottom rails, MS frames shall be covered with hit moulded plain coulour PVC 'C' chanel having a PVC sheet strip of 20mm width stuck in side with screws. all as specified and directed by Engr-in-charge
S&F Solid PVC door frame of size 50 mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, fixed in opening all as specified and directed by Engr-in-charge
S&F 100 mm size PVC butt hinges all as specified and directed by Engr-in-charge
S&F 125MM PVC handles all as specified and directed by Engr-in-charge
S&F 200mm long PVC tower bolt all as specified and directed by Engr-in-charge
S&F PVC(SWR) Floor trap 75mm plain with CP grating including jointing to wate pipe with solvent cement complete all as specified and directed by Engr-in-charge
M&L for 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in floors/walls as soil pipe all as specified and directed by Engr-in-charge
S&F PVC (SWR) bends of any radius for 110 mm dia rain water pipes with rubber ring joints a complete all as specified and directed by Engr-in-charge
Dismanteling 500ltr water storage tank and removing to store all as specified and directed by Engr-in-charge
S&F Rotational moulded polythene water storage tank cylindrical vertical with closed top 500ltr capacity hoisted and fixed in position incl 20 mm bore ball brass valves high pressure with polythene float and fly nut all as specified in SSR Part-1.all as specified and directed by Engr-in-charge
S & F 125mm Brass chromium plated shower rose complete all as specified and directed by Engr-in-charge
S &F CP stop cock / cast copper alloy with crutch screwed down screwed for brass ferrule for 15 mm bore pipe after of any description complete all as specified and directed by Engr-in-charge
S&F Bib taps for 15 mm dia bore pipe cast copper alloy cromium plated with capstain head screwed down for iron pipe or brass ferrule and fixed all as specified and directed by Engr-in-charge
S&F Pillar taps hot and cold Mixer Cast copper alloy fancy type 15mm bore , with capstan heads chromium plated screwed down high pressure with or without lettered Hot or Cold mixer with long screwed shanks and fly nuts scrrewed for iron pipe and fixed. all as specified and directed by Engr-in-charge
S&F stop cock cast copper alloy chromium plated fancy type ,high pressure with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule for 15 mm bore pipe after taking down old stop cock of any description complete all as specified and directed by Engr-in-charge
S&F Angle stop valve(Concealed type) cast copper alloy chromium plated with capstan head , long shank and cup screwed down screwed for iron pipe or for brass ferrule for 15 mm bore pipeafter taking down old stop cock of any description complete all as specified.
S&F 450 mm long PVC connection with brass nuts on both ends for 15mm bore pipes of approved quality complete all as specified and directed by Engr-in-charge
S&F Viterous china, wash hand basin, white, flat back, size 550x400mm including PVC waste pipe 32mm bore and mild steel brackets, fixed all in repairs, including cutting for or pinning in brackets complete all as specified and directed by Engr-in-charge
S&F Tubular towel rail, CP 20mm dia, 60cm long between flanges fixed in repairs.all as specified and directed by Engr-in-charge
S&F in repairs low level flushing cistern of PVC 10 ltr capicity incl 45cm long PVC connection with brass nut at both ends, 15 dia stop cock cast copper alloy,screwed both ends , high pressure(wt not less than as specified in SSR), PVC flush pipe 32 mm bore complete all as specified and directed by Engr-in-charge
S&F Vitreous China wash down water closet pan (Pedestal Pattern), white including white plastic seat cover with mild steel CP hinging device, suitable brass CP wash jet, complete jointing, connecting and making good the disturbed all as specified and directed by Engr-in-charge
S&FHealth faucet (ABS Body) with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed by Engr-in-charge
S&F CP toilet paper holder with flap model including taking down old unserviceable existing one complete all as specified and directed by Engineer-in-Charge.
S&F Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms) complete all as specified and directed by Engineer-in-Charge.
Hard core of broken bricks of gauge n exc. 63 mm spread and levelled in layers n exc.15cm thick, watered and rammed to a true surface all as specified and directed by Engr-in-charge
M&L PCC (1:3:6), 50mm thick as in PCC path/ plinth protection.finished the surfaces even and smooth with out using extra cement all as specified and directed by Engr-in-charge
M&L Machine pressed precast concrete inter locking paver block any shape and size made of M-35 grade concrete (with grey cement and no pigment) of 60mm thickness with 6mm top layer of anti abrasive material laid over 25mm thick (compacted) fine sieved sand complete all as specified and directed by Engr-in-charge
M&L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub base of flooring.all as specified and directed by Engr-in-charge
M&L Machine cut Kota stone slab flooring 20mm (+2mm) thick laid over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4 as base laid and jointed with grey cement slurry mixed with pigment to match the shade the slab including rubbing and polishing complete all as specified and directed by Engr-in-charge
All as per item No 68 here in before on vertical surfaces as in skirting/dado of size as required all as specified and directed by Engr-in-charge
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness, including cover fillets all as specified and directed by Engr-in-charge
M&L anodised aluminium snap grid false ceiling of grid size 605x605mm consisting of aluminium main and "T' sections of size 25x35x1.5mm thick and wall angles of size 25x 25x 1.5 mm thick suspended with GI wire suspenders of 6mm dia of suitable length and 8-10 mm thick gypsum board, 60x60 cm size fixed with staples on snap grid complete all as specified and directed by Engr-in-charge
S&F PVC wall panelling of hollow section size 150x10mm (colour/pattern as approved by AO) complete fixed in position in all respect including supply and fixing of all accessories like fasteners/ screws/ solvent etc all as recommended by manufacturer, complete all as specified and directed by Engr-in-charge
S & F mild steel peg set of 6 fixed to wall with steel screws complete all as specified & directed.all as specified and directed by Engr-in-charge
S&F PVC enclosed case (cabin type) with cover and looking mirror over it with two shelves in it complete all as specified and directed by Engr-in-charge
Demolition of reinforced cement concrete of any description (Reinforecement cut as required to facilitate demolition ) complete all as specified and directed by Engr-in-charge
M & L for precast RCC 1:2:4, type B-1 as in man hole cover slabs using 20mm graded stone aggregate and set in CM 1:4 including necessary form work all as specified and directed by Engr-in-charge Note : Reinforcement shall be measured and paid separately under item No. 13 below
M&L Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending and binding with and including mild steel wire (annealed) not less than 0.9 mm dia all as specified and directed by Engr-in-charge
M & L for150mm bore, cement concrete bed 1:3:6 type C2, using 40mm graded stone aggregate to drain pipes including packing under and haunching against the sides of pipes after they are laid and fitted for the following sizes all as specified and directed by Engr-in-charge
Excavation in trenches not exc 1.5m wide and not exc 1.5m in deep and getting out in soft and loose soil for foundations, etc or for shafts, wells, cesspits, manholes, pier holes, etc complete all as specified and directed by Engr-in-charge
Removing excavated material(soil) to a distance not exc 50mm and depositing where directed at a level n.exc 1.50m above the starting point complete all as specified and directed by Engr-in-charge
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick in soils complete all as specified and directed by Engr-in-charge
M&L Reinforced concrete pipes, class NP2 laid and jointed complete with collars bore in pipes 150mm all as specified and directed by Engr-in-charge
M&L for cement concreate 1:2:4 type B-1 using 20mm graded stone aggregate as in surface channel and drain all as specified and directed by Engr-in-charge
M&L preparing of new surface of wood and wood based material of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamel pain and one coat of pink primer all as specified and directed by Engr-in-charge
S&F powder coated aluminium glazing/ doors & shutters made out of aluminium anodised section 101.60x44.75x1.75mm for chowkats or frame & shutters made of size 81.25x38.10x1.75mm for side rails, top rails and bottom rails and including 12mm thick High Density Fibre Board pre-laminated on both sides (water proof) above and below middle/lock rail, and to be fixed with and including EPDM gasket to render the glazing, air and water tight etc. & aluminium beeds 20mm size with and including fixing required nos. of pivots/hinges and brass mortice lock (four levers) and two Nos of keys, required mongry shall be measured and paid seprately complete all as specified and directed by Engr-in-charge
Dismantling of brick tiles or terracing tiles single layar on roofs complete att all as specified and directed by Engr-in-charge
Demolation of mud puska and removing any thickness all as specified and directed by Engr-in-charge
M&L PCC 1:3:6, type B-0 using 12.5 mm graded stone aggregates as in padding over roof ,minimum thickness at khurra as 50mm maintain a slope of 1:100 using water proofing compound finish even and smooth without using extra cementcomplete all as specified and directed by Engr-in-charge
Cutting grooves in brick wall ,75 mm wide and 65 mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed by Engr-in-charge
M&L PCC 1:2:4, type B-0 using 12.5 mm graded stone aggregates as in roof kerbs or mud stops/ coping etc including weathering slightly rounded or chamferred finish even and smooth without using extra cement all as specified.
S&F PVC ( SWR) rain water pipes 110 mm bore single socketed in any length with rubber ring joints fixed to walls complete as as pecified including flat iror clamps 25x3mm complete all as specified including taking out old damaged AC rain water pipes. all as specified and directed by Engr-in-charge
M&L Rotational moulded polythene water storage tank cylindrical vertical with closed top 500ltr capacity hoisted and fixed in position incl demolition of exisiting Rcc tank and incl 20 mm bore ball brass valves high pressure with polythene float and fly nut all as specified and directed by Engr-in-charge
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete with fittings and fixtures such as switches, ceiling roses, pendants, regulators, socket, lamp holders brackets, bulk head fittings etc removing material for taking credit ( credit shall be recovered as per credit Sch attached) and also making good disturbed surfaces of wall, floors etc all as specified and as directed by the Engineer-in-Charge.
M&L for point wiring with 1.50 sqmm in copper conductor cable (multistrand) FRLS single core PVC insulated cable in and including PVC concealed conduit (ISI Marked) of heavy duly with all accessories ie PVC gutties etc terminated in sunken/pressed metal flush box and white modular cover plate with frame for mounting of switches /sockets/ fan regulators etc and continuous earth wire 1.5 Sqmm copper cable PVC insulated FRLS controlled by one switch for one light/fan/sockets point/ all as specified and directed by Engr-in-Charge in ceiling Portion surface conduit wiring to be done. Note: i) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost ii) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth.iii) Neccessary cutting chasing wherever required and making good the disturbed surface shall be part of job at no extra cost.
All as per item No 105 above, but for one 3/5 pin socket outlet 5 Amp on independent board complete all as specified and as directed by the Engineer-in-Charge.
All as per item No 105 above, but for one 3/5 pin socket outlet 5 Amp on the same board with other switches complete all as specified and as directed by the Engineer-in-Charge.
All as per serial item No 105 here-in-before , but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor ( Multi-stranded) PVC insulated and unsheating electric cable 1100 volts (ISI Marked) including PVC insulated and unsheathed electric cable 1100 volts 2.5 Sqmm copper stranded conductor as continuous earth wire connected to common earth dolly complete all as specified and as directed by Engineer-in-Charge.
M&L for Modular switch 1 way 6A, 1 module type all as specified and directed.
M&L for Modular switch 1 way 16A, 1 module type all as specified and directed.
M&L for Modular Socket, 6A - 5 pin, 2 module type all as specified and directed
M&L for Modular Socket 6A/16A - 2/3 pin, 2 module type all as specified and directed.
S&F in replacement of existing unserviceable FTL with new techonlgy ultra bright led tubelight with aluminium heat sink & polycarbonate diffuser having high efficacy of capacity 20 Watt Warm White with BOX TYPE Pre-coated CRCA body, heavy duty regal Batten for LED tube universal batten for G13 t8 lamps including neccesary fitting on wall and making electric connection from ceiling rose to connector with suitable size of electric cable and making good the disturbed surface.
S & F LED light fitting 1x9W/1X10W bulkhead luminaires 230 Volts including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified by Engr-in-Charge.
Material and labour for ceiling rose surface type, 65 mm x 50 mm two to three terminals / PVC / polycarbonate, isolated body fixed on PVC block complete all specified and as directed by the Engineer-in-Charge.
Material and labour for angular type lamp holder, PVC/ polycarbonate type with back plate suitable for 9 to 15 watt for batten fitting, complete all as specified.
Supply and fix LED Lamp LED new Adore 9W WW Ball Lamp LHLDERHEMD 8X007 9 watt.
Material and labour for call bell ding dong AC 230 volt single pole complete all as specified.
Material and labour for Modular Bell push 6A 1 module complete.
M&L for replacement of existing earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth plate not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth wire 4mm dia by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) including iron angle frme 40*40*6mm. and medium grade GI watering pipe 20mm dia with funnel and wire mesh and 15 mm bore GI pipe light grade proection pipe including excavation and charcoal ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I .
M & L for Fan step regulator, 120W - 1 module
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) (Against BER)
Refixing of Ceiling Fan duly painted with 2 coat of paint over one coat of primer all as directed by engr-in-charge.
S&F in replacement of exhaust fan metal body, AC single phase 230/ 240 V of size 250/300 mm sweep with louver . Note: Fixing of Exhaust Fan on wall with suitable size anchor bolt , making hole in wall for groutng and making good the disturbed surface including plaster work shall be part of job at no extra cost. (Against BER)
S&F Vertical three phase MCB distribution board powder coated double door flush mounted complete with locking arrangement suitable for 4 way VTPN, with IP-54 proctection including MCCB of capacity 100 Amp FP as incomers and MCB's as out going with rated bus bar 200 Amp link 230 volt (Note: (i) The DB shall be flush fixed ,and making good the disturbed surface matching with existing specifications shall be part of job at no extra cost.(ii)connection of theMCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble properly crimped.(iii) all the vacant holes of the DB shall be provided with blank plates of appropriate size. (Cost of MCCB incl in the item of rate)
S&F in replacement of existing unserviceable Sheet metal enclosure with new DB’s suitable for MCBs of single pole and neutral 8 way double door type, IP-54 with 200 amp rated bus bar. Note: i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. ii) The disturbed surface shall be match with existing shall be part of job.
S& F in replacement of MCB SP up to 6-32 Amp all as specified and directed.
S&F in replacement of MCB SPN 6-32 Amp complete all as specified and directed.
M&L for Sub main wiring with 2 runs of single core FRLS PVC insulated unsheathed multistranded copper conductor cable of size 2x6 sqmm (line conductor) & 1x6 sqmm (earth conductor), 1100 volt grade drawing in & including heavy duty non metallic PVC conduit, ISI marked, incl accessories not less than 25 mm in dia & concealed in wall, roof etc including PVC insulated, FRLSH unsheathed single core multistranded copper conductor cable, green in colour as earth conductor including cutting charges for concealed conduit wiring etc and making good cutting not exceeding 10 cm grith complete all as specified and directed. Note: (i) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth. (ii) Connections of cables with MCBs or bus bars shall be done through brass/copper thimbles of appropriate size. (iii) Two runs of copper conductor cable and one run of copper earth wire including PVC conduit will be measured and paid as one unit only.
S&F in replacement of existing unserviceable Plug & Socket Box (sheet metal) with PVC Plug, SPN 20 Amps for Acs. Model No. - DHDPHSN020, Make-Havells.
M&L for Sub main wiring with 2 runs of single core FRLSH PVC insulated unsheathed multistranded copper conductor cable of size 2x4 sqmm ( line conductor) & 1x4 sqmm ( earth conductor), 1100 volt grade drawing in & including heavy duty non metallic PVC conduit , ISI marked, incl accessories not less than 25 mm in dia & concealed in wall, roof etc including PVC insulated, FRLSH unsheathed single core multistranded copper conductor cable, green in colour as earth conductor including cutting charges for concealed conduit wiring etc and making good cutting not exceeding 10 cm grith complete all as specified and directed. Note: (i) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth. (ii) Connections of cables with MCBs or bus bars shall be done through brass/copper thimbles of appropriate size. (iii) Two runs of copper conductor cable and one run of copper earth wire including PVC conduit will be measured and paid as one unit only.
S & F new generation energy saving and environmental friendly long life LED building security light 1x25 watts, IP-54, made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07, with all accessories including suitable bracket with suitable dia light grade GI pipe bend to shape, including MS clamp of size of required size and PVC cable 1.5 Sqmm twincore from ceiling rose to light fittings complete all as specified and directed.
Supply & lay in replacement of existing unserviceable XLPE insulated, armoured heavy dutyelectric cable with aluminium conductor, 1100 volt grade of crosssectional area 35 Sqmm 3.5 Core all as specified & directed by Engr-in-Charge.
S & F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm, 2 core laid in trenches /on poles / walls / in ducts / passing through pipes and including necessary cable lugs, bolts, nuts and washers complete all as specified and directed.
Excavating in trenches n exc 1.5m wide and n exc 1.5m deep and getting out in hard/dense soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as specified and directed.
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
Material and labour for sand cushioning with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming completed all as specified and directed.
Supply and laying well burnt sub class ‘B’ bricks. ( designated 75) locally available best quality laid dry in trenches for protection of underground cable all as specified and directed.
Material and labour for replacement of GI tubing light grade 50 mm bore for passing through cables under the floor, along the wall or along the pole complete all as specified and directed.
M/S RAJ KUMAR GUPTA
NARINDER KUMAR SONS
m/s k.k. construction co.
AGGARWAL & CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .