Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹5.8 L+₹2.2 L (58.9%)Rejected-Finance | L2 | Rejected-Finance Being L2 |
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
7 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE HQ 134 WKS ENGRS
HQ 134 WKS ENGRS PIN-914134 C/O 56 APO
REP AND MAINT OF HT EXTERNAL ELECT, REPLACEMENT OF HT CONDUCTORS AND UG CABLES AT HQ CIF (K) UNDER AGE (I) CIF (K)
2021_MES_453390_2
HQ 134 WE-04/2021-22
Open Tender
Civil Works
Item Rate
120 days
SRINAGAR
PLEASE SEE TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
AGE (I) CIF (K)
₹10,000
Yes
7 Sept 2021
23 Jul 2021
9 Aug 2021
23 Jul 2021
7 Aug 2021
23 Jul 2021
60 days
Amount
M&L for cross arms, bracings, supports, clamps, shackle and back plates fabricated from structural steel section including nuts, bolts, washers, welding/bending cold or hot drilling holes for bolts in any shape or size as required including two coats of aluminium paint over a coat of aluminium red oxide primer including taking down existing unservicable cross arms, bracings, supports, clamps, shackle and back plates etc complete all as specified and directed.
Stay assembly using 20mm dia MS stay rod and stay plate of size 300x300x6mm thick, stay bow, loop insulator 90x140 mm made of porcelain vitreous and galvanised stay strand of size 7/4mm suitable for 11m pole, nuts, bolts and check nuts of GI shackle and clamp etc all as shown in Electrical Plate No 01 of SSR Part-I of 2009 including taking down existing unservicable stay assembly, etc complete all as specified and directed. (Note : Excavation/earthwork and PCC in fdn shall be measured and paid separately.)
Dismantling of old UNSV ACSR conductor of any size or type and M&L new ACSR conductor steel reinforced any size in over head lines on HT poles including stretching the aluminium conductor and binding with binding wires of aluminium or aluminium tapes etc. jumpers and connections, complete all as specified and directed by Engr-in-Charge.
Pin type insulator of size 150mm height and 150mm dia made out of porcelain vitreous (white/brown or green) including one galvanized mild steel spindle, two galvanized washers round and one galvanized iron nut for working pressure 11000 volts grade, including taking out existing unserviceable insulator of any type/description etc complete all as specified and directed. Make : Rastriya/Jaipuriya/BHEL
Disc type insulator, vitreous 145 mm high and 255 mm dia ball and socket type, white, brown or green two in series assembly for tension with tension clamps for conductors working pressure 11000 volts,including taking out existing unserviceable insulator of any type/description etc complete all as specified and directed. Make : Rastriya/Jaipuriya/BHEL
Supply and install, testing and commissioning air break isolating Switch triple pole mechanically operated with vertical/horizontal isolated mounting on 12 insulator and steel frame with mechanism worked from ground level and including operating rod 25mm dia medium GI of required lenght and locking arrangments of capacity 11 KV with and including drop out fuse set complete including making all incoming/outgoing connections all as directed and painting of steel work with two coats of aluminium paint over a coat of primer and taking down old and unserviceable switch complete all as specified and directed by Engr-in-Charge.
Supply and filling of fresh transformer power oil of BDV not less than 50 KV for topping up of reduced level due to evorapation/ leakage/ loss due to dehydration in HT 33 KV transformer/HT 11 KV AVR /Distribution transformer 100 to 600 KVA complete including removing of old unserviceable transformer oil, complete all as specified and directed by the Engr-in-Charge. Make: Powerlink/poweroil/Savita/Midel
Dehydration/Oil filtration by stream line/vacuum type filter machine to improve BDV including routine testing after filteration complete all as specified and directed by the Engr-in-Charge.
Earthing complete with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below ground level connected to galvanized iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point, GI tubing 15mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel and wire mesh, charcoal and salt, 40mm thick pre-cast RCC (1:2:4) type B-0 (Nominal mix) cover reinforced with XPM (weighing n.less than 4 Kg/Sqm) with suitable steel handle, and angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-0 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, complete all as directed. Notes:- (i) Main earthing strip from earth plate electrode to test point upto length of 7.5 meters length shall deem to be included in the unit rate quoted against this item. (ii) GI protection pipe 15 mm sia bore & earthing lead beyond 7.5 metre shall be measured and paid for seperately under appropriate item of Sch A part-I. (iii) On testing after completion if the desired resistenance is not obtained the contrator shall redo the earthing without any extra cost to the department.
Replacement of danger notice plate of 1.6mm thick mild steel sheet, vitreous, enamelled white with letters. figures and conventional skull and bones in signal red colour and fixed with MS clamps made of 25x3mm MS flat, bolts and nuts for HT 25 x 20 cm size complete all as directed including taking down old danger notice plate, complete all as specified and directed by Engr-in-Charge.
S&F of galvanised steel wire 4mm dia/3.15 mm dia streching on overhead HT lines using earthing continuty conducter, including taking out existing unserviceable steel wire of any type/description etc complete all as specified and directed. complete all as specified and directed by the Engr-in-Charge.
Removal of existing burnt joint and supply and fixing new Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint for 3 core XLPE armoured aluminium conductor cable of size 120sqmm to 185sqmm with jointing material and accessories including testing etc complete all as specified and directed.
Removal of existing burnt joint and supply and fixing new Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint for 3 core XLPE armoured aluminium conductor cable of size 120sqmm to 185sqmm with jointing material and accessories including testing etc complete all as specified and directed.
Removal of existing burnt joint and supply and fixing new Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint for 3 core XLPE armoured aluminium conductor cable of size 50sqmm to 95sqmm with jointing material and accessories including testing etc complete all as specified and directed.
Removal of existing burnt joint and supply and fixing new Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint for 3 core XLPE armoured aluminium conductor cable of size 50sqmm to 95sqmm with jointing material and accessories including testing etc complete all as specified and directed.
Disconnecting the windings of loose overhead conductors of HT lines from insulators and restringing the same for proper sag and rewinding including aluminum winding wires, tapes etc and jumpering for any type of conductor complete all as directed. Note : (i) Trimming of tree branches upto 3m all round the conductors are deemed to be included in the quoted rates. (ii) Three ACSR conductor will be measured as one unit length for payment.
GI tubing 80 mm bore light grade laid in trenches/floors/ fixed to wall/poles for protection of cable with necessary fittings and FI clamps not less than 2mm thick duly painted etc including removing the rusted UNSV tubing completed all as specified and directed.
PCC, M-7.5 (1:4:8), type D-2 (using 40mm graded crushed stone aggregates) as in foundation, filling and mass concrete for poles complete all as specified and directed by Engineer-in-Charge.
PCC ,M-15 (1:2:4), type B-2 (using 20mm graded crushed stone aggregates) as in coping of poles complete all as specified and directed by Engineer-in-Charge.
Supply & filling of stone aggregate 40 mm surronding the transformer,Panel board and under the two/four pole structure , complete all as specified and directed by Engr-in-Charge.
Strip opening of transformer of capacity 163 KVA to 400 KVA, 11KV/433 Volts indoor each/outdoor type of any make after unscrewing nuts & bolts, screws and connected accessories job such as breather , conservator tank, temp gauge etc. for replacement of defective parts such as replacement of leaking gaskets, replacement of worn out/burnt out studs checking and cleaning of contacts of tap changer and re-assembling the transformer after replacing the defective parts/repair complete all as specified and directed by Engr-in-Charge. Note :- (i) Payment of defective parts to be replaced shall be measured and paid for separately as supply only under respective items and all labour component includes in this item. (ii) The cost for replacement of packing material such as top gasket insulator's gasket shall deem to be included in the unit rate quoted by the contractor against this item. (iii) The repair/strip opening of transformers shall be carried out at site of its installation without taking down/removal of transformer from the site of installation.
Supply only for replacement of 11 KV HT brass terminal rod with nuts, bolts, washers and bushings suitable for indoor/outdoor type transformer of any make and capacity from 160 KVA to 400KVA, complete all as specified and directed by the Engr-in-Charge.
Supply only for replacement of LT bush for indoor/outdoor type 160 KVA to 250 KVA transformers complete with including brass stud,4 Nos brass nuts & brass cups set, complete all as specified and directed by the Engr-in-Charge.
Supply only for replacing silica gel , complete all as specified and directed by the Engr-in-Charge.
M&L for drawing out the VCBs 11 KV, 3 Phase bus bar, 630 Amp, CT ratio 100/ 5 Amp, 02 Nos and busbar 630 Amp CT ratio 50/ 5Amp -04 Nos from the HT 11 KV panel, servicing complete with necessary tightening to nuts & bolts, oiling, greasing, autometion & caliberation to all relays equiped in the panel complete all as specified and directed by Engr-in-Charge.
M&L for replacement of lightening arrestors expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amps suitable for 11000 volts (11KV), complete all as required at site or as directed by Engr-in-Charge.
Excavation in trenches in any type of soil, not exc 1.5m wide and not exc. 1.5m in depth for laying of cables/pipes etc and getting out, etc complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25cm thick, etc complete all as specified and directed.
Removing excavated material (soil) to a distance not exc. 50m and depositing where directed etc complete all as specified and directed.
Supply & spreading in trenches clean dry sand including gently punning around cable, etc complete all as specified and directed. (Note: Punned thickness shall be measured)
Supplying & laying precast concrete cable cover, class HV type -2 with peak unreinforced of size 450mm x 180mm x 40 mm for protection of cable abutting each laid dry flat width equal to the length of the cable cover etc complete all as specified and directed
Supply, laying and testing HT cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts grade cross section area 120 sqmm 3 core complete laid in trenches, duct, passing through pipe, fixed to poles complete all as specified and directed by Engr-in-Charge.
CHINAR CONSTRUCTION TRADERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .