Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Ref. No.
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
Closing Date
7 Oct 2021, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Rahul
Power Grid Corporation of India Limited Saudamini 3rd Floor, Plot No.-2, Sector-29 Gurgaon (Haryana) - 122001
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
TBCB/400kV/ Rajgarh /SS01/G1/R
Limited
Electrical Works
Works
Pachora Bhopal Rajgarh
7 Oct 2021
29 Jun 2021
7 Oct 2021
29 Jun 2021
7 Oct 2021
29 Jun 2021
7 Jul 2021
Package Name 400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
Package Code SS01
Specification No. TBCB/400kV/Rajgarh/SS01/G1/R
TBCB/400kV/Rajgarh/SS01/G1/R
1 Fill up only green shaded cells in Sch-1, Sch-2, Sch-3 and Bid Form 2nd Envelope.
2 All the cells in Sch-5 & Sch-6 are auto filled, therefore no cell is required to be filled up there.
3 Instructions / error messages, if any, will be displayed automatically after selecting the cell.
4 After filling up all the schedues, save the file, take print out of all the schedules and Bid form and sign & stamp and submit them as hard copy of the 2nd envelope (Price part) of the bid. Also ensure to submit the soft copy of the the same file on CD/ DVD.
पावर ग्रिड कारपोरेशन ऑफ इण्डिया लिमिटेड
(भारत सरकार का उद्यम)
Power Grid Corporation of India Limited
(A Government of India Enterprises)
I While filling up the worksheets following may please be observed :
(i) Fill up only green shaded cells.
(ii) Certain data type entries have been restricted, such as Numeric values or limits of numeric values.
(iii) Select only the options provided in pull down menus.
(iv) Do not link any cell of this work book with any other work book.
(v) Do not use copy & paste or cut & paste options for filling up the data.
(vi) Do not reformat any of the cell of the work book.
II This Workbook consists of following worksheets :
Opening page of the workbook.
Names of Bidder :
● Fill up names and address of the Sole Bidder and /or Joint Venture.
● Fill up date in dd-mmm-yyyy format from drop down menu.
● Click for Sch-1 given at the right top of the worksheet to go to Sch-1.
Sch-1 (Ex-works Prices) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
● Type Test charges shall appear automatically after filling up Sch-7 appropriately.
Sch-2 (Freight & Insurance Charges) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
Sch-3 (Installation Charges) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
Sch-4 (Training Charges) :
● Not applicable, hence no cell is required to be filled up.
Sch-5 (Summary of Taxes and Duties applicable on the Goods) :
● No cell is required to be filled in by the bidder in this worksheet.
● Summary of all the Schedules without considering discount (mentioned in the work sheet discount) shall be displayed automatically.
● No cell is required to be filled in by the bidder in this worksheet.
Sch-7 (Type Test Charges) :
● Not applicable, hence no cell is required to be filled up.
● Total of this Sch-7 shall automatically appear in Sch-1.
Bid from 2nd Envelope :
● Fill up ref. no. as bidder's ref no. of this letter.
● This letter shall consider the net price as per Sch-6 (After Discount).
● Fill up names & Designation of the representatives of other JV partner(s) if the bidder is JV (Joint Venture) .
● Fill up additional information as required.
Happy Bidding !
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
TBCB/400kV/Rajgarh/SS01/G1/R Sole Bidder 1
JV (Joint Venture) 2 or More
Enter following details of the bidder
Specify type of Bidder [Select from drop down menu] Sole Bidder 0
Name of Sole Bidder …….. …….. …….. …….. …….. ……..
Address of Sole Bidder …….. …….. …….. …….. …….. ……..
Name of other Partner - 1
Address of other Partner - 1
Name of other Partner - 2 (more, if any) …….. …….. …….. …….. …….. ……..
Address of other Partner - 2 (more, if any) …….. …….. …….. …….. …….. ……..
email ID of Bid Signatory
Mobile No. of Bid Signatory
Tel No. of Bid Signatory
Fax No. of Bid Signatory
TBCB/400kV/Rajgarh/SS01/G1/R Schedule - 1 Direct Total #REF! Sole Bidder `
BO Total #REF! 0
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
(SCHEDULE OF RATES AND PRICES)
Bidder’s Name and Address (Sole Bidder) : To:
Contracts Services, 3rd Floor
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Plant and Equipment (including Mandatory Spares Parts) to be supplied, including Type Test Charges for Tests to be conducted Direct
All Prices are in Indian Rupees. Bought-Out
SI. No. Activity Description Material Code HSN Code Whether HSN in column ‘ 2 ’ is confirmed. If not indicate applicable the HSN code * Rate of GST applicable ( in %) Whether rate of GST in column ‘4’ is confirmed. If not indicate applicable rate of GST * Item Description Unit Qty. Unit Ex-works price (excluding GST) Total Ex-works price (excluding GST) GST as confirmed by Bidder
400/220kV Pachora SEZ PP (New)
1 420kV Bus Reactor 1000000705 85042330 18% 125 MVAR, 420kV, 3-phase Bus Reactor excluding Insulating Oil EA 1 Included 0.00 0 0.00
2 420kV Bus Reactor 1000013947 85049010 18% Insulating Oil for 125 MVAR, 420kV 3-phase Bus Reactor SET 1 Included 0.00 0 0.00
3 420kV Bus Reactor 1000025218 85049010 18% On line insulating oil drying system (Cartridge type)(As per technicalspecification) EA 1 Included 0.00 0 0.00
4 420kV Line Reactor 1000006176 85042320 18% 80 MVAR,420kV,3-phase Shunt Reactor excluding Insulating Oil EA 2 Included 0.00 0 0.00
5 420kV Line Reactor 1000014015 85049010 18% Insulating Oil for 80 MVAR,420kV ,3-phase Shunt Reactor withassociated NGR SET 2 Included 0.00 0 0.00
6 420kV Line Reactor 1000025212 73090090 18% Oil Storage Tank (20kL) EA 2 Included 0.00 0 0.00
7 420kV Line Reactor 1000030173 85049010 18% NEUTRAL GROUNDING REACTOR-W/O INSUL OIL EA 2 Included 0.00 0 0.00
8 420kV Line Reactor 1000028234 85049010 18% 120kV Surge Arrester along with support structure & terminal SET 2 Included 0.00 0 0.00
9 420kV Line Reactor 1000025218 85049010 18% On line insulating oil drying system (Cartridge type)(As per technicalspecification) EA 2 Included 0.00 0 0.00
10 LT Transformer 1000004951 85042100 18% 630kVA, 33/0.433kV, 3ph LT Transformer EA 2 Included 0.00 0 0.00
11 420kV Equipment 1000004501 85352913 18% 420kV, 3150A, 63kA Circuit Breaker (3-Phase) without closing resistorand with Support Structure EA 11 Included 0.00 0 0.00
12 420kV Equipment 1000009713 85389000 18% Controlled Switching Device for 420 kV, 3-ph Circuit Breaker EA 4 Included 0.00 0 0.00
13 420kV Equipment 1000004463 85359090 18% 420 kV, 3000A, 63KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 27 Included 0.00 0 0.00
14 420kV Equipment 1000004535 85359090 18% 420 kV, 4400 pF Capacitive Voltage Transformer (1-Phase) EA 12 Included 0.00 0 0.00
15 420kV Equipment 1000004498 85353090 18% 420kV, 3150A, 63KA, Isolator (3-phase)(Double Break) with one E/S EA 24 Included 0.00 0 0.00
16 420kV Equipment 1000020419 85354010 18% 336kV Surge Arrester (1-phase) EA 24 Included 0.00 0 0.00
17 420kV Equipment 1000004401 85462040 18% 420 kV, 1 phase Bus Post Insulator (except for Line Traps) EA 39 Included 0.00 0 0.00
18 420kV Equipment 1000004499 85353090 18% 420kV, 3150A, 63KA Isolator (3-phase)(Double Break) with two E/S EA 2 Included 0.00 0 0.00
19 245kV Equipment 1000001683 85352912 18% 245kV, 1600A, 50KA Circuit Breaker(3-Phase) with support structure EA 10 Included 0.00 0 0.00
20 245kV Equipment 1000028442 85352912 18% 245kV, 3150A, 50KA Circuit Breaker(3-Phase) with support structure EA 1 Included 0.00 0 0.00
21 245kV Equipment 1000001684 85359090 18% 245 kV, 1600A, 50KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 30 Included 0.00 0 0.00
22 245kV Equipment 1000001739 85359090 18% 245 kV, 2500A, 50KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 3 Included 0.00 0 0.00
23 245kV Equipment 1000001689 85353090 18% 245kV, 1600A, 50 KA, 3-phase DoubleBreak Isolator with two E/S EA 10 Included 0.00 0 0.00
24 245kV Equipment 1000001688 85353090 18% 245kV, 1600A, 50 KA, 3-phase DoubleBreak Isolator with one E/S EA 10 Included 0.00 0 0.00
25 245kV Equipment 1000032777 85353090 18% 245KV, 1600 A, 50KA, 3-PHASE, DOUBLE BREAK TANDEM ISOLATOR WITHOUT E/S EA 19 Included 0.00 0 0.00
26 245kV Equipment 1000051760 85353090 18% 245KV, 3150A, 50KA, 3-PHASE DOUBLE BREAK ISOLATOR WITH TWO E/S EA 2 Included 0.00 0 0.00
27 245kV Equipment 1000020417 85354010 18% 216kV Surge Arrester (1-phase) EA 27 Included 0.00 0 0.00
28 245kV Equipment 1000001772 85359090 18% 245 kV, 4400pf Capacitive Voltage Transformer (1- Phase) EA 24 Included 0.00 0 0.00
29 245kV Equipment 1000001695 85462040 18% 245 kV, 1 phase Bus Post Insulator (except for Line Traps) EA 132 Included 0.00 0 0.00
30 145kV Equipment 1000000945 85352911 18% 145kV, 1250A, 31.5KA Circuit Breakers(1-Phase) with support structure EA 2 Included 0.00 0 0.00
31 145kV Equipment 1000000956 85462040 18% 145kV, 1 phase Bus Post Insulators EA 2 Included 0.00 0 0.00
32 72.5kV Equipment 1000005036 85352113 18% 72.5 kV, 1250A, 25 kA, 3-phase CircuitBreaker with support structure EA 1 Included 0.00 0 0.00
33 72.5kV Equipment 1000005061 85359090 18% 72.5 kV, 50A, 25 kA, 1-Phase CurrentTransformer with 120% extended currentrating EA 3 Included 0.00 0 0.00
34 72.5kV Equipment 1000005048 85359090 18% 72.5 kV Voltage Transformer (1- Phase) EA 3 Included 0.00 0 0.00
35 72.5kV Equipment 1000005070 85353090 18% 72.5 kV, 400A, 25 KA, 3-Phase DoubleBreak Isolator with out E/S EA 1 Included 0.00 0 0.00
36 72.5kV Equipment 1000005030 85462040 18% 72.5kV ,1 phase Bus Post Insulators EA 6 Included 0.00 0 0.00
37 36kV Equipment 1000020418 85354010 18% 30kV Surge Arrester (1-Phase) EA 3 Included 0.00 0 0.00
38 36kV Equipment 1000002032 85462040 18% 36kV, 1 phase Bus Post Insulators as per Technical Specification EA 3 Included 0.00 0 0.00
39 36kV Equipment 1000028100 85049010 18% 36 kV, 3-Ph Horn Gap Fuse as per Technical Specification EA 1 Included 0.00 0 0.00
40 36kV Equipment 1000002087 85353090 18% 36 kV, 400A, 25 KA, 3-Phase HDB Isolatorwithout E/S EA 1 Included 0.00 0 0.00
41 Erection Hardware - 420kV 1000011322 72169990 18% Erection Hardware for 400kV I type layout-Line bay as per technicalspecification SET 2 Included 0.00 0 0.00
42 Erection Hardware - 420kV 1000011327 72169990 18% Erection Hardware for 400kV I type layout-Transformer bay as pertechnical specification SET 3 Included 0.00 0 0.00
43 Erection Hardware - 420kV 1000011317 72169990 18% Erection Hardware for 400kV I type layout-Bus Reactor bay as pertechnical specification SET 1 Included 0.00 0 0.00
44 Erection Hardware - 420kV 1000011318 72169990 18% Erection Hardware for 400kV I type layout-Bus Work (For one diameter)as per technical specification SET 3 Included 0.00 0 0.00
45 Erection Hardware - 420kV 1000034966 72169990 18% ERECTION HARDWARE FOR 420 KV I TYPE LAYOUT-SWITCHABLE LINE REACTORSBAY INCLUDING NGR BYPASS ARRANGEMENT AS PER TECHNICAL SPECIFICATION SET 2 Included 0.00 0 0.00
46 Erection Hardware - 245kV 1000011261 72169990 18% Erection Hardware for 220kV layout (Double Main and TransferScheme)-Line Bay as per technical specification SET 6 Included 0.00 0 0.00
47 Erection Hardware - 245kV 1000011264 72169990 18% Erection Hardware for 220kV layout (Double Main and TransferScheme)-Transformer Bay as per technical specification SET 3 Included 0.00 0 0.00
48 Erection Hardware - 245kV 1000011265 72169990 18% Erection Hardware for 220kV layout (Double Main and TransferScheme)-Transfer Bus Coupler Bay as per technical specification SET 1 Included 0.00 0 0.00
49 Erection Hardware - 245kV 1000011253 72169990 18% Erection Hardware for 220kV layout (Double Main and TransferScheme)-Bus Coupler Bay as per technical specification SET 1 Included 0.00 0 0.00
50 Erection Hardware - 245kV 1000011255 72169990 18% Erection Hardware for 220kV layout (Double Main and TransferScheme)-Bus work (one Bay) as per technical specification SET 11 Included 0.00 0 0.00
51 Erection Hardware - 72.5kV 1000011348 72169990 18% Erection Hardware for the 72.5kV equipment for Tertiary loading as pertechnical specification SET 1 Included 0.00 0 0.00
52 Erection Hardware - 36kV 1000032412 85049010 18% ERECTION HARDWARE FOR AUXILIARY LT TRANSFORMER SET 1 Included 0.00 0 0.00
53 400kV Control & Relay Panel 1000002165 85371000 18% 400kV Circuit Breaker Relay Panel with Auto Reclose (with Automation) EA 4 Included 0.00 0 0.00
54 400kV Control & Relay Panel 1000002163 85371000 18% 400kV Circuit Breaker Relay Panel without Auto Reclose (withAutomation) EA 7 Included 0.00 0 0.00
55 400kV Control & Relay Panel 1000003398 85371000 18% 400kV Line Protection Panel (with Automation) EA 2 Included 0.00 0 0.00
56 400kV Control & Relay Panel 1000004274 85371000 18% 400kV Transformer Protection Panel (For both HV & MV side)-(withAutomation) EA 3 Included 0.00 0 0.00
57 400kV Control & Relay Panel 1000003407 85371000 18% 400kV Reactor Protection Panel (with Automation) EA 1 Included 0.00 0 0.00
58 400kV Control & Relay Panel 1000002145 85371000 18% 400kV Bus Bar Protection Panel (Duplicate)-(with Automation) SET 1 Included 0.00 0 0.00
59 220kV Control & Relay Panel 1000001168 85371000 18% 220kV Circuit Breaker Relay Panel without Auto Reclose (withAutomation) EA 4 Included 0.00 0 0.00
60 220kV Control & Relay Panel 1000001170 85371000 18% 220kV Circuit Breaker Relay Panel with Auto Reclose (with Automation) EA 7 Included 0.00 0 0.00
61 220kV Control & Relay Panel 1000001330 85371000 18% 220kV Line Protection Panel (with Automation) EA 6 Included 0.00 0 0.00
62 220kV Control & Relay Panel 1000001166 85371000 18% 220kV Bus Bar Protection Panel (Single)-(with Automation) SET 1 Included 0.00 0 0.00
63 Common Equipment - CRP 1000021642 85371000 18% Time synchronisation equipment EA 1 Included 0.00 0 0.00
64 Common Equipment - CRP 1000025391 82032000 18% Relay Test kit EA 1 Included 0.00 0 0.00
65 Substation Automation System 1000003408 85371000 18% Complete Substation automation System for 400kV Main bay as perTechnical Specification EA 8 Included 0.00 0 0.00
66 Substation Automation System 1000003410 85371000 18% Complete Substation automation System for 400kV Tie bay as perTechnical Specification EA 3 Included 0.00 0 0.00
67 Substation Automation System 1000049676 85371000 18% SUBSTATION AUTOMATION SYSTEM FOR 220KV LINE BAY AS PER TECHNICALSPECIFICATION EA 6 Included 0.00 0 0.00
68 Substation Automation System 1000049675 85371000 18% SUBSTATION AUTOMATION SYSTEM FOR 220KV TRANSFORMER BAY AS PERTECHNICAL SPECIFICATION EA 3 Included 0.00 0 0.00
69 Substation Automation System 1000038471 85371000 18% COMPLETE SUBSTATION AUTOMATION SYSTEM FOR 220KV TBC BAY ASPER TECHNICAL SPECIFICATION EA 1 Included 0.00 0 0.00
70 Substation Automation System 1000038470 85371000 18% COMPLETE SUBSTATION AUTOMATION SYSTEM FOR 220KV BUS COUPLER BAY AS PER TECHNICAL SPECIFICATION EA 1 Included 0.00 0 0.00
71 Substation Automation System 1000018700 85371000 18% Complete Substation automation System for controlling and monitoringof Auxilary System including BCUs as per technical specification SET 1 Included 0.00 0 0.00
72 PLCC Equipment at Pachora SEZ PP 1000004290 85176210 18% 400kV,3150A,0.5mH ,63kA Line Trap EA 4 Included 0.00 0 0.00
73 PLCC Equipment at Pachora SEZ PP 1000004400 85462040 18% 420 kV ,1 phase Bus Post Insulators for Line Traps EA 12 Included 0.00 0 0.00
74 PLCC Equipment at Pachora SEZ PP 1000010014 85176210 18% Coupling device for PLCC SET 2 Included 0.00 0 0.00
75 PLCC Equipment at Pachora SEZ PP 1000000046 85176210 18% Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 3 Included 0.00 0 0.00
76 PLCC Equipment at Pachora SEZ PP 1000010638 85176210 18% Digital Protection Coupler EA 2 Included 0.00 0 0.00
77 PLCC Equipment at Pachora SEZ PP 1000036908 85446020 18% HF CABLE 75 OHMS FOR PLCC KM 2.000 Included 0.00 0 0.00
78 PLCC Equipment at Pachora SEZ PP 1000002134 85176210 18% 4wire telephone equipment EA 3 Included 0.00 0 0.00
79 PLCC Equipment at Pachora SEZ PP 1000017887 85176210 18% Analog Protection Coupler for PLCC EA 2 Included 0.00 0 0.00
80 PLCC Equipment at Pachora SEZ PP 1000001568 85176210 18% 220kV,1600A,0.5mH ,50kA Line Trap EA 12 Included 0.00 0 0.00
81 PLCC Equipment at Pachora SEZ PP 1000001694 85462040 18% 245 kV ,1 phase Bus Post Insulators for Line Traps EA 36 Included 0.00 0 0.00
82 PLCC Equipment at Pachora SEZ PP 1000025769 85176210 18% Testing & Maintenance equipment (print test kit only) for PLCC SET 1 Included 0.00 0 0.00
83 PLCC Equipment at Pachora SEZ PP 1000011082 85176210 18% EPAX (24/8) with 24 telephones, Cables etc. SET 1 Included 0.00 0 0.00
84 PLCC Equipment at Bhopal SS 1000010014 85176210 18% Coupling device for PLCC SET 2 Included 0.00 0 0.00
85 PLCC Equipment at Bhopal SS 1000000046 85176210 18% Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 3 Included 0.00 0 0.00
86 PLCC Equipment at Bhopal SS 1000017887 85176210 18% Analog Protection Coupler for PLCC EA 2 Included 0.00 0 0.00
87 PLCC Equipment at Bhopal SS 1000010638 85176210 18% Digital Protection Coupler EA 2 Included 0.00 0 0.00
88 PLCC Equipment at Bhopal SS 1000036908 85446020 18% HF CABLE 75 OHMS FOR PLCC KM 1.000 Included 0.00 0 0.00
89 PLCC Equipment at Bhopal SS 1000002134 85176210 18% 4wire telephone equipment EA 2 Included 0.00 0 0.00
90 LT Switchgear 1000004313 85371000 18% 415V Main Switchboard SET 1 Included 0.00 0 0.00
91 LT Switchgear 1000004303 85371000 18% 415V AC Distribution Board (ACDB) as per Technical Specification SET 1 Included 0.00 0 0.00
92 LT Switchgear 1000004310 85371000 18% 415V MLDB(along with 2 nos. 100 kVA Lighting transformer) SET 1 Included 0.00 0 0.00
93 LT Switchgear 1000004307 85371000 18% 415V Emergency LDB(along with 1 no. 100kVA lighting transformer) SET 1 Included 0.00 0 0.00
94 LT Switchgear 1000001144 85371000 18% 220V DCDB SET 2 Included 0.00 0 0.00
95 LT Switchgear 1000004754 85371000 18% 48V DCDB SET 2 Included 0.00 0 0.00
96 Battery & Battery Charger 1000027411 85072000 28% 48V Battery set SET 2 Included 0.00 0 0.00
97 Battery & Battery Charger 1000027377 85072000 28% 220V Battery set SET 2 Included 0.00 0 0.00
98 Battery & Battery Charger 1000027575 85044030 18% 220V Float Cum Boost Battery Charger EA 2 Included 0.00 0 0.00
99 Battery & Battery Charger 1000027578 85044030 18% 48V Float Cum Boost Battery Charger EA 2 Included 0.00 0 0.00
100 DG Set 1000001893 85021200 18% 250 kVA Diesel Generator along with control Panel SET 1 Included 0.00 0 0.00
101 Air Conditioning System 1000013502 84158210 28% High wall type split AC unit of 2 TR capacity EA 20 Included 0.00 0 0.00
102 Air Conditioning System 1000006285 84151090 28% Air conditioning system for Switchyard Panel Room of 9m length SET 1 Included 0.00 0 0.00
103 Air Conditioning System 1000006284 84151090 28% Air conditioning system for Switchyard Panel Room of 6m length SET 6 Included 0.00 0 0.00
104 Fire Protection System 1000012031 84819090 18% Pumping arrangement for HVW system & hydrant system, complete withall piping, valves, fittings,etc. inside pump house for FireProtection System of 400/220kV (New) Substation SET 1 Included 0.00 0 0.00
105 Fire Protection System 1000012036 84819090 18% Hydrant system, complete piping andaccessories etc. outside the Pump Housefor Fire Protection of 400/220kV (New)Substation SET 1 Included 0.00 0 0.00
106 Fire Protection System 1000012014 85311020 18% Fire Detection and Alarm System for Control Room Building(400kV) SET 1 Included 0.00 0 0.00
107 Fire Protection System 1000012019 85311020 18% Fire Detection and Alarm System for Switchyard Panel Room of 9 mlength SET 1 Included 0.00 0 0.00
108 Fire Protection System 1000012018 85311020 18% Fire Detection and Alarm System for Switchyard Panel Room of 6 mlength SET 6 Included 0.00 0 0.00
109 Fire Protection System 1000012069 84248990 18% HVW spray system, Hydrant system and complete U/G & O/G piping andaccessories etc. out side the pump house for 500MVA , 400KV/220/33kV, 3-phase Autotransformer SET 3 Included 0.00 0 0.00
110 Fire Protection System 1000012042 84248990 18% HVW spray system, Hydrant system and complete U/G & O/G piping andaccessories etc. out side the pump house for 125 MVAR, 420kV, 3 phaseBus Reactor SET 1 Included 0.00 0 0.00
111 Fire Protection System 1000012048 84248990 18% HVW spray system, Hydrant system and complete U/G & O/G piping andaccessories etc. out side the pump house for 80 MVAR, 420kV 3 phaseShunt Reactor SET 2 Included 0.00 0 0.00
112 Fire Protection System 1000012027 84241000 18% 9litre water type Portable Fire extinguisher EA 20 Included 0.00 0 0.00
113 Fire Protection System 1000012022 84241000 18% 4.5 kg CO2 type Portable Fire extinguisher EA 15 Included 0.00 0 0.00
114 Fire Protection System 1000049665 84241000 18% 60 LITRE FOAM TYPE TROLLEY/WHEEL MOUNTED FIRE EXTINGUISHER SET 4 Included 0.00 0 0.00
115 Fire Protection System 1000012024 84241000 18% Fire Extinguisher Dry Chemical Powder Type(5 Kg) for control room. EA 8 Included 0.00 0 0.00
116 Illumination System 1000009647 94059900 18% Control room cum administrative building (400kV) illumination LOT 1 Included 0.00 0 0.00
117 Illumination System 1000028047 94059900 18% Fire fighting pumphouse building illimunation excluding conduit LS 1 Included 0.00 0 0.00
118 Illumination System 1000013796 94059900 18% Illumination System for switchyard panel room of 9 m length LS 1 Included 0.00 0 0.00
119 Illumination System 1000013795 94059900 18% Illumination System for switchyard panel room of 6 m length LS 6 Included 0.00 0 0.00
120 Illumination System 1000014547 85371000 18% Lighting Panel type ACP-2 as per technical specification EA 3 Included 0.00 0 0.00
121 Illumination System 1000020262 85371000 18% Sub Lighting panel (outdoor) type SLP (Switchyard and Street Lighting) EA 5 Included 0.00 0 0.00
122 Illumination System 1000038039 94051090 18% LIGHTING FIXTURE LED LUMINAIRES TYPE FL-1 AS PER TECH. SPECIFICATIONS EA 70 Included 0.00 0 0.00
123 Illumination System 1000038325 94059900 18% LIGHTING FIXTURE LED LUMINAIRES TYPE FL2 AS PER TECH. SPECIFICATIONS EA 140 Included 0.00 0 0.00
124 Illumination System 1000004952 94059900 18% 63A, 415V : Interlocked switch socket outdoor Receptacle (type RP) asper technical specifications EA 2 Included 0.00 0 0.00
125 Illumination System 1000025538 76169990 18% Self Supported Aluminium Ladder as Per Technical Specification EA 1 Included 0.00 0 0.00
126 Illumination System 1000024515 76169990 18% Cartwheel Mounted Aluminium Ladder as Per Technical Specification EA 1 Included 0.00 0 0.00
127 Illumination System 1000001894 94059900 18% Outdoor Power Receptacle for oilfiltration unit (250A) EA 2 Included 0.00 0 0.00
128 Illumination System 1000038389 94051090 18% LED STREET LIGHT LUMINAIRE TYPE SL-L1 (= 45W)AS PER TECHNICALSPECIFICATION EA 40 Included 0.00 0 0.00
129 Illumination System 1000038397 94059900 18% TYPE L1 STREET LIGHTING POLE OF 6 METER AS PER TECHNICALSPECIFICATION. EA 40 Included 0.00 0 0.00
130 Illumination System 1000030151 94059900 18% Security Room Illumination including conduit LS 1 Included 0.00 0 0.00
131 Visual Monitoring System 1000025861 85287390 28% Visual Monitoring System for Watch & Ward SET 1 Included 0.00 0 0.00
132 Cables 1000032045 85446090 18% 33KV GRADE HT XLPE CABLE ALONG WITH CLAMPS,LUGS, GLANDS AND STRAIGHTJOINTS. KM 2.000 Included 0.00 0 0.00
133 Cables 1000000444 85446090 18% 1.1kV grade Power Cables (XLPEinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 Included 0.00 0 0.00
134 Cables 1000049673 85446090 18% 1.1KV GRADE POWER & CONTROL CABLE (PVC) 400 KV LINE BAY ALONGWITHCLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC SET 2 Included 0.00 0 0.00
135 Cables 1000049488 85446090 18% 1.1KV GRADE POWER & CONTROL CABLE (PVC) 400 KV TIE BAY ALONGWITHCLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC SET 3 Included 0.00 0 0.00
136 Cables 1000049487 85446090 18% 1.1KV GRADE POWER & CONTROL CABLE (PVC) 400 KV ICT BAY ALONGWITHCLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC SET 3 Included 0.00 0 0.00
137 Cables 1000049486 85446090 18% 1.1KV GRADE POWER & CONTROL CABLE (PVC) 400 KV BUS REACTOR BAYALONGWITH CLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC SET 1 Included 0.00 0 0.00
138 Cables 1000050124 85446090 18% 1.1KV GRADE POWER & CONTROL CABLE (PVC) FOR 400 KV LINE REACTOR BAYALONGWITH CLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC SET 2 Included 0.00 0 0.00
139 Cables 1000049485 85446090 18% 1.1KV GRADE POWER & CONTROL CABLE (PVC) 220 KV LINE BAY ALONGWITHCLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC SET 6 Included 0.00 0 0.00
140 Cables 1000049484 85446090 18% 1.1KV GRADE POWER & CONTROL CABLE (PVC) 220 KV ICT BAY ALONGWITHCLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC SET 3 Included 0.00 0 0.00
141 Cables 1000049483 85446090 18% 1.1KV GRADE POWER & CONTROL CABLE (PVC) 220 KV BUS COUPLER BAYALONGWITH CLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC SET 1 Included 0.00 0 0.00
142 Cables 1000049671 85446090 18% 1.1KV GRADE POWER & CONTROL CABLE (PVC) 220 KV TRANSFER BUS COUPLERBAY ALONGWITH CLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC SET 1 Included 0.00 0 0.00
143 Cables 1000049482 85446090 18% 1.1KV GRADE OTHER CABLES (NOT COVERED ABOVE) ALONGWITH CLAMPS, LUGS,GLANDS, STRAIGHT THROUGH JOINTS ETC LS 1 Included 0.00 0 0.00
144 400kV Gantry Structure 1000046563 73082011 18% GANTRY STRUCTURE PER DIAMETER- 400 KV ONE & HALF BREAKER LAYOUT SET 3 Included 0.00 0 0.00
145 220kV Gantry Structure 1000046562 73082011 18% GANTRY STRUCTURE FOR LINE BAY- 220 KV DOUBLE MAIN & TRANSFER LAYOUT SET 6 Included 0.00 0 0.00
146 220kV Gantry Structure 1000046567 73082011 18% GANTRY STRUCTURE FOR TRANSFORMER BAY- 220 KV DOUBLE MAIN & TRANSFERLAYOUT SET 3 Included 0.00 0 0.00
147 220kV Gantry Structure 1000046560 73082011 18% GANTRY STRUCTURE FOR BUS COUPLER BAY- 220 KV DOUBLE MAIN & TRANSFERLAYOUT SET 1 Included 0.00 0 0.00
148 220kV Gantry Structure 1000046565 73082011 18% GANTRY STRUCTURE FOR TRANSFER BUS COUPLER BAY- 220 KV DOUBLE MAIN &TRANSFER LAYOUT SET 1 Included 0.00 0 0.00
149 400kV Equipment Support Structure 1000049653 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV CT (1PH) EA 27 Included 0.00 0 0.00
150 400kV Equipment Support Structure 1000049654 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV CVT (1PH) EA 12 Included 0.00 0 0.00
151 400kV Equipment Support Structure 1000049657 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV ISOLATOR (3PH) EA 26 Included 0.00 0 0.00
152 400kV Equipment Support Structure 1000049655 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV CLASS SA (1PH) EA 24 Included 0.00 0 0.00
153 400kV Equipment Support Structure 1000049652 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV BPI (1PH) EA 39 Included 0.00 0 0.00
154 400kV Equipment Support Structure 1000049656 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV WAVE TRAP (1PH) EA 4 Included 0.00 0 0.00
155 220kV Equipment Support Structure 1000049647 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-220KV CT (1PH) EA 33 Included 0.00 0 0.00
156 220kV Equipment Support Structure 1000049648 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-220KV CVT (1PH) EA 24 Included 0.00 0 0.00
157 220kV Equipment Support Structure 1000049651 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-220KV ISOLATOR (3PH) EA 41 Included 0.00 0 0.00
158 220kV Equipment Support Structure 1000049649 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-220KV CLASS SA (1PH) EA 27 Included 0.00 0 0.00
159 220kV Equipment Support Structure 1000050459 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-220KV HIGH BPI (1PH)(BUS HEIGHT-8M APPROX.) SET 33 Included 0.00 0 0.00
160 220kV Equipment Support Structure 1000049646 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-220KV BPI (1PH) EA 99 Included 0.00 0 0.00
161 220kV Equipment Support Structure 1000049650 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-220KV WAVE TRAP (1PH) EA 12 Included 0.00 0 0.00
162 145kV Equipment Support Structure 1000050973 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-145KV BPI (1PH) EA 2 Included 0.00 0 0.00
163 72.5kV Equipment Support Structure 1000049659 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-72.5KV CT(1PH) EA 3 Included 0.00 0 0.00
164 72.5kV Equipment Support Structure 1000049660 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-72.5KV PT (1PH) EA 3 Included 0.00 0 0.00
165 72.5kV Equipment Support Structure 1000049661 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-72.5KV ISOLATOR (3PH) EA 1 Included 0.00 0 0.00
166 72.5kV Equipment Support Structure 1000049658 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-72.5KV BPI (1PH) EA 6 Included 0.00 0 0.00
167 36kV Equipment Support Structure 1000028542 73082011 18% STRUCTURE FOR-33KV H-TYPE POLE STRUCTURE EA 1 Included 0.00 0 0.00
168 Main Earthmat 1000032055 72159090 18% 40 MM MS ROD FOR MAIN EARTHMAT KM 15.000 Included 0.00 0 0.00
169 Mandatory Spares-Bus Reactor 1000028245 85049010 18% Spare For 400kV Bus Reactor LS 1 Included 0.00 0 0.00
170 Mandatory Spares-Line Reactor 1000028266 85049010 18% Spares for 420kV Shunt Reactor LS 1 Included 0.00 0 0.00
171 Mandatory Spares Lumpsum 1000019918 85359090 18% Spares for 420kV Circuit Breaker LS 1 Included 0.00 0 0.00
172 Mandatory Spares Lumpsum 1000019919 85353090 18% Spares for 420kV Double break Isolator LS 1 Included 0.00 0 0.00
173 Mandatory Spares Lumpsum 1000024186 85354010 18% SPARES FOR 336KV SURGE ARRESTER LS 1 Included 0.00 0 0.00
174 Mandatory Spares Lumpsum 1000025943 85359090 18% Spare-420kV CVT 1 SET 1 Included 0.00 0 0.00
175 Mandatory Spares Lumpsum 1000025940 85462040 18% Spare-420kV BPI SET 1 Included 0.00 0 0.00
176 Mandatory Spares Lumpsum 1000025941 85389000 18% Spare-420kV CT 1 SET 1 Included 0.00 0 0.00
177 Mandatory Spares Lumpsum 1000025935 85389000 18% Spare-245kV Circuit Breaker SET 1 Included 0.00 0 0.00
178 Mandatory Spares Lumpsum 1000025936 85353090 18% Spare-245kV Isolator SET 1 Included 0.00 0 0.00
179 Mandatory Spares Lumpsum 1000025933 85389000 18% Spare-245kV CT SET 1 Included 0.00 0 0.00
180 Mandatory Spares Lumpsum 1000025934 85359090 18% Spare-245kV CVT SET 1 Included 0.00 0 0.00
181 Mandatory Spares Lumpsum 1000025932 85462040 18% Spare-245kV BPI SET 1 Included 0.00 0 0.00
182 Mandatory Spares Lumpsum 1000019912 85371000 18% Relay & protection Panels (with automation) LS 1 Included 0.00 0 0.00
183 Mandatory Spares Lumpsum 1000019927 85389000 18% Spares-Substation Automation System LS 1 Included 0.00 0 0.00
184 Mandatory Spares Lumpsum 1000025950 85176210 18% Spare-PLCC SET 1 Included 0.00 0 0.00
185 Mandatory Spares Lumpsum 1000019915 85030010 18% Spares for DG set LS 1 Included 0.00 0 0.00
186 Mandatory Spares Lumpsum 1000019914 85049090 18% Spares fpr 220V Battery Charger LS 1 Included 0.00 0 0.00
187 Mandatory Spares Lumpsum 1000019921 85044030 18% Spares fpr 48V Battery Charger LS 1 Included 0.00 0 0.00
188 Mandatory Spares Lumpsum 1000019913 85079090 28% Spares for 220V Batteries LS 1 Included 0.00 0 0.00
189 Mandatory Spares Lumpsum 1000019920 85079090 28% Spares for 48V Batteries LS 1 Included 0.00 0 0.00
190 Mandatory Spares Lumpsum 1000032289 84819090 18% SPARES FOFIRE PROTECTION SYSTEM SET 1 Included 0.00 0 0.00
191 Mandatory Spares Lumpsum 1000053851 76169990 18% SPARES FOR CLAMPS & CONNECTORS LOT 1 Included 0.00 0 0.00
192 Comm Eqpt at Pachora SEZ PP SUPPLY MAIN 1000031367 85176260 18% SDH EQUIPMENT (STM-16 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-BASEEQUIPMENT (COMMON CARDS, CROSS CONNECT/CONTROL CARDS, OPTICAL BASECARDS, POWER SUPPLY CARDS, POWER CABLING, OTHER HARDWARE ANDACCESSORIES INCLUDING SUB RACKS, PATCH CORD, DDF ETC FULLY EQUIPEDEXCLUDING OPTICAL INTERFACE & TRIBUTARY CARDS EA 1 Included 0.00 0 0.00
193 Comm Eqpt at Pachora SEZ PP SUPPLY MAIN 1000019316 85176290 18% Optical Line Interface card To support minimum 200 km EA 2 Included 0.00 0 0.00
194 Comm Eqpt at Pachora SEZ PP SUPPLY MAIN 1000031374 85176290 18% TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 2 Included 0.00 0 0.00
195 Comm Eqpt at Pachora SEZ PP SUPPLY MAIN 1000034950 85176990 18% ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 2 Included 0.00 0 0.00
196 Comm Eqpt at Pachora SEZ PP SUPPLY MAIN 1000031381 85176290 18% TRIBUTARY INTERFACE-GIGABIT ETHERNET INTERFACES 10/100 MBPS WITH LAYER-2 SWITCHING (MINIMUM 2 NOS.) SET 1 Included 0.00 0 0.00
197 Comm Eqpt at Pachora SEZ PP SUPPLY MAIN 1000026228 85176290 18% Equipment Cabinets For SDH EA 1 Included 0.00 0 0.00
198 Comm Eqpt at Pachora SEZ PP SUPPLY MAIN 1000028495 84715000 18% NMS- CRAFT TERMINAL-HARDWARE EA 1 Included 0.00 0 0.00
199 Comm Eqpt at Pachora SEZ PP SUPPLY MAIN 1000028265 85238020 18% Software for Craft Terminal EA 1 Included 0.00 0 0.00
200 Comm Eqpt at Pachora SEZ PP SUPPLY MAIN 1000034998 85171890 18% VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 4 Included 0.00 0 0.00
201 Comm Eqpt at Pachora SEZ PP SUPPLY MAIN 1000030942 85447090 18% 24F (DWSM) APPROACH FIBRE OPTIC CABLE INCLUDING ALL INSTALLATIONHARDWARE SET KM 1.000 Included 0.00 0 0.00
202 Comm Eqpt at Pachora SEZ PP SUPPLY MAIN 1000023471 85372000 18% OPGW Fibre Optic Distribution Panel (FODP): Indoor Type: 96F EA 1 Included 0.00 0 0.00
203 Comm Eqpt at SEZ PP SUPPLY Spare 1000031369 85176260 18% SDH EQUIPMENT (STM-16 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-COMMONCARDS, CROSS-CONNECT/CONTROL CARDS, OPTICAL BASE CARD, POWER SUPPLYCARDS, POWER CABLING, OTHER HARDWARE & ACCESSORIES (EACH). SET 1 Included 0.00 0 0.00
204 Comm Eqpt at SEZ PP SUPPLY Spare 1000019316 85176290 18% Optical Line Interface card To support minimum 200 km EA 1 Included 0.00 0 0.00
205 Comm Eqpt at SEZ PP SUPPLY Spare 1000031374 85176290 18% TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 1 Included 0.00 0 0.00
206 Comm Eqpt at SEZ PP SUPPLY Spare 1000034950 85176990 18% ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 1 Included 0.00 0 0.00
207 Comm Eqpt at SEZ PP SUPPLY Spare 1000031381 85176290 18% TRIBUTARY INTERFACE-GIGABIT ETHERNET INTERFACES 10/100 MBPS WITH LAYER-2 SWITCHING (MINIMUM 2 NOS.) SET 1 Included 0.00 0 0.00
208 Comm Eqpt at SEZ PP SUPPLY Spare 1000034998 85171890 18% VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 1 Included 0.00 0 0.00
209 Comm Eqpt at SEZ PP SUPPLY Spare 1000031398 85171890 18% PRE CONNECTORIZED OPTICAL FIBER PATCH CORDS(10 MTRS) – PACK OF SIXPATCH CORDS SET 1 Included 0.00 0 0.00
210 Comm Eqpt at SEZ PP SUPPLY Spare 1000030942 85447090 18% 24F (DWSM) APPROACH FIBRE OPTIC CABLE INCLUDING ALL INSTALLATIONHARDWARE SET KM 1.000 Included 0.00 0 0.00
211 Supply : PMU & associated items-Pachora 1000017518 85364900 18% PMU with GPS Clock (clock can be either internal or external) EA 2 Included 0.00 0 0.00
212 Supply : PMU & associated items-Pachora 1000022512 90311000 18% WAMS Hardware - Time System (GPS receiver) EA 2 Included 0.00 0 0.00
213 Supply : PMU & associated items-Pachora 1000022510 85176290 18% WAMS Hardware - Substation Grade Layer-3 LAN Switches with minimum 4 x10/100 Mbps Ethernet ports and 2 x 1 Gbps Ethernet ports EA 3 Included 0.00 0 0.00
214 Supply : PMU & associated items-Pachora 1000022487 85447090 18% WAMS Miscellaneous - Armored Fibre Optic Cable and associatedtermination (e.g. L2 Switch) for connecting PMU panels located indifferent control room of a station EA 1 Included 0.00 0 0.00
400kV Bhopal (Sterlite) extension
215 420kV Equipment 1000004535 85359090 18% 420 kV, 4400 pF Capacitive Voltage Transformer (1-Phase) EA 6 Included 0.00 0 0.00
216 420kV Equipment 1000020419 85354010 18% 336kV Surge Arrester (1-phase) EA 6 Included 0.00 0 0.00
217 420kV Equipment 1000004401 85462040 18% 420 kV, 1 phase Bus Post Insulator (except for Line Traps) EA 14 Included 0.00 0 0.00
218 420kV Equipment 1000004501 85352913 18% 420kV, 3150A, 63kA Circuit Breaker (3-Phase) without closing resistorand with Support Structure EA 4 Included 0.00 0 0.00
219 420kV Equipment 1000004463 85359090 18% 420 kV, 3000A, 63KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 12 Included 0.00 0 0.00
220 420kV Equipment 1000004498 85353090 18% 420kV, 3150A, 63KA, Isolator (3-phase)(Double Break) with one E/S EA 10 Included 0.00 0 0.00
221 PLCC Equipment 1000004400 85462040 18% 420 kV ,1 phase Bus Post Insulators for Line Traps EA 12 Included 0.00 0 0.00
222 PLCC Equipment 1000004290 85176210 18% 400kV,3150A,0.5mH ,63kA Line Trap EA 4 Included 0.00 0 0.00
223 400kV Control & Relay Panel 1000002165 85371000 18% 400kV Circuit Breaker Relay Panel with Auto Reclose (with Automation) EA 4 Included 0.00 0 0.00
224 400kV Control & Relay Panel 1000003398 85371000 18% 400kV Line Protection Panel (with Automation) EA 2 Included 0.00 0 0.00
225 400kV Control & Relay Panel 1000006843 85371000 18% Augmentation of existing 400kV bus bar protection scheme SET 1 Included 0.00 0 0.00
226 Substation Automation System 1000003409 85371000 18% Augmentation of Substation automation System for 400kV Main bay as perTechnical Specification EA 2 Included 0.00 0 0.00
227 Substation Automation System 1000003411 85371000 18% Augmentation of Substation automation System for 400kV Tie bay as perTechnical Specification EA 2 Included 0.00 0 0.00
228 Erection Hardware - 420kV 1000011318 72169990 18% Erection Hardware for 400kV I type layout-Bus Work (For one diameter)as per technical specification SET 2 Included 0.00 0 0.00
229 Erection Hardware - 420kV 1000011322 72169990 18% Erection Hardware for 400kV I type layout-Line bay as per technicalspecification SET 2 Included 0.00 0 0.00
230 Air Conditioning System 1000006284 84151090 28% Air conditioning system for Switchyard Panel Room of 6m length SET 1 Included 0.00 0 0.00
231 Fire Protection System 1000012018 85311020 18% Fire Detection and Alarm System for Switchyard Panel Room of 6 mlength SET 1 Included 0.00 0 0.00
232 Fire Protection System 1000012022 84241000 18% 4.5 kg CO2 type Portable Fire extinguisher EA 2 Included 0.00 0 0.00
233 Illumination System 1000013795 94059900 18% Illumination System for switchyard panel room of 6 m length LS 1 Included 0.00 0 0.00
234 Illumination System 1000014547 85371000 18% Lighting Panel type ACP-2 as per technical specification EA 1 Included 0.00 0 0.00
235 Illumination System 1000020262 85371000 18% Sub Lighting panel (outdoor) type SLP (Switchyard and Street Lighting) EA 2 Included 0.00 0 0.00
236 Illumination System 1000038387 94051090 18% LED FLOOD LIGHT LUMINARIESTYPE FL-1 (150W) AS PER TECHNICALSPECIFICATION EA 10 Included 0.00 0 0.00
237 Illumination System 1000038325 94059900 18% LIGHTING FIXTURE LED LUMINAIRES TYPE FL2 AS PER TECH. SPECIFICATIONS EA 10 Included 0.00 0 0.00
238 Illumination System 1000038389 94051090 18% LED STREET LIGHT LUMINAIRE TYPE SL-L1 (= 45W)AS PER TECHNICALSPECIFICATION EA 10 Included 0.00 0 0.00
239 Illumination System 1000038397 94059900 18% TYPE L1 STREET LIGHTING POLE OF 6 METER AS PER TECHNICALSPECIFICATION. EA 10 Included 0.00 0 0.00
240 ACDB/DCDB 1000004304 85371000 18% 415V ACDB (Extn.) SET 1 Included 0.00 0 0.00
241 ACDB/DCDB 1000001145 85371000 18% 220V DCDB (Extn.) SET 1 Included 0.00 0 0.00
242 Cables 1000049673 85446090 18% 1.1KV GRADE POWER & CONTROL CABLE (PVC) 400 KV LINE BAY ALONGWITHCLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC SET 2 Included 0.00 0 0.00
243 Cables 1000049488 85446090 18% 1.1KV GRADE POWER & CONTROL CABLE (PVC) 400 KV TIE BAY ALONGWITHCLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC SET 2 Included 0.00 0 0.00
244 Cables 1000049482 85446090 18% 1.1KV GRADE OTHER CABLES (NOT COVERED ABOVE) ALONGWITH CLAMPS, LUGS,GLANDS, STRAIGHT THROUGH JOINTS ETC LS 1 Included 0.00 0 0.00
245 Main Earthmat 1000032055 72159090 18% 40 MM MS ROD FOR MAIN EARTHMAT KM 2.500 Included 0.00 0 0.00
246 400kV Gantry Structure 1000015954 73082011 18% Fabrication, galvanising and supply of Lattice Structures (MS Steel),to be designed during detailed engineering, for towers, beams andequipment support structure including pack plates / packwashers andgusset plates excluding fasteners and foundation bolts MT 87.000 Included 0.00 0 0.00
247 400kV Gantry Structure 1000011713 73082011 18% Fabrication, galvanising and supply of fasteners ( nuts, bolts andwashers ) including step bolts for lattice and pipe structures to bedesigned during detailed engineering MT 4.000 Included 0.00 0 0.00
248 400kV Gantry Structure 1000012373 73082011 18% Fabrication, galvanising and supply of foundation bolts including nuts,checknut and washers for lattice and pipe structures to be designedduring detailed engineering MT 1.000 Included 0.00 0 0.00
249 400kV Equipment Support Structure 1000049654 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV CVT (1PH) EA 6 Included 0.00 0 0.00
250 400kV Equipment Support Structure 1000049655 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV CLASS SA (1PH) EA 6 Included 0.00 0 0.00
251 400kV Equipment Support Structure 1000049652 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV BPI (1PH) EA 14 Included 0.00 0 0.00
252 400kV Equipment Support Structure 1000049656 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV WAVE TRAP (1PH) EA 4 Included 0.00 0 0.00
253 400kV Equipment Support Structure 1000049653 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV CT (1PH) EA 12 Included 0.00 0 0.00
254 400kV Equipment Support Structure 1000049657 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV ISOLATOR (3PH) EA 10 Included 0.00 0 0.00
255 Mandatory Spares 1000019918 85359090 18% Spares for 420kV Circuit Breaker LS 1 Included 0.00 0 0.00
256 Mandatory Spares 1000019919 85353090 18% Spares for 420kV Double break Isolator LS 1 Included 0.00 0 0.00
257 Mandatory Spares 1000024186 85354010 18% SPARES FOR 336KV SURGE ARRESTER LS 1 Included 0.00 0 0.00
258 Mandatory Spares 1000025943 85359090 18% Spare-420kV CVT 1 SET 1 Included 0.00 0 0.00
259 Mandatory Spares 1000025940 85462040 18% Spare-420kV BPI SET 1 Included 0.00 0 0.00
260 Mandatory Spares 1000025941 85389000 18% Spare-420kV CT 1 SET 1 Included 0.00 0 0.00
261 Mandatory Spares 1000019912 85371000 18% Relay & protection Panels (with automation) LS 1 Included 0.00 0 0.00
262 Mandatory Spares 1000019927 85389000 18% Spares-Substation Automation System LS 1 Included 0.00 0 0.00
263 Mandatory Spares 1000053851 76169990 18% SPARES FOR CLAMPS & CONNECTORS LOT 1 Included 0.00 0 0.00
264 Visual Monitoring System 1000030433 85287390 28% COLOR IP CAMERA, WITH PAN, TILT AND ZOOM FACILITIES, ALONGWITH ALLREQUIRED ITEMS, ACCESSORIES, LINE INTERFACE UNITS, FIBER PATCH CORDS,POWER SUPPLY UNITS, JUNCTION BOXES, CABLES, FIBER OPTIC CABLES, ETC.,AND INCLUDING INTEGRATION IN EXISTING HARDWARE AND SOFTWARE FORAUGMENTATION OF VISUAL MONITORING SYSTEM AS PER TECHNICALSPECIFICATION. SET 1 Included 0.00 0 0.00
265 Supply:PMU & assoc items-Bhopal 1000017518 85364900 18% PMU with GPS Clock (clock can be either internal or external) EA 2 Included 0.00 0 0.00
266 Supply:PMU & assoc items-Bhopal 1000022512 90311000 18% WAMS Hardware - Time System (GPS receiver) EA 2 Included 0.00 0 0.00
267 Supply:PMU & assoc items-Bhopal 1000022510 85176290 18% WAMS Hardware - Substation Grade Layer-3 LAN Switches with minimum 4 x10/100 Mbps Ethernet ports and 2 x 1 Gbps Ethernet ports EA 3 Included 0.00 0 0.00
268 Supply:PMU & assoc items-Bhopal 1000022487 85447090 18% WAMS Miscellaneous - Armored Fibre Optic Cable and associatedtermination (e.g. L2 Switch) for connecting PMU panels located indifferent control room of a station EA 1 Included 0.00 0 0.00
269 Communication Eqpt at Bhopal SS 1000031367 85176260 18% SDH EQUIPMENT (STM-16 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-BASEEQUIPMENT (COMMON CARDS, CROSS CONNECT/CONTROL CARDS, OPTICAL BASECARDS, POWER SUPPLY CARDS, POWER CABLING, OTHER HARDWARE ANDACCESSORIES INCLUDING SUB RACKS, PATCH CORD, DDF ETC FULLY EQUIPEDEXCLUDING OPTICAL INTERFACE & TRIBUTARY CARDS EA 1 Included 0.00 0 0.00
270 Communication Eqpt at Bhopal SS 1000018706 85176990 18% S16.1 SFP EA 4 Included 0.00 0 0.00
271 Communication Eqpt at Bhopal SS 1000023721 85176260 18% SFP S4.1 EA 4 Included 0.00 0 0.00
272 Communication Eqpt at Bhopal SS 1000019316 85176290 18% Optical Line Interface card To support minimum 200 km EA 2 Included 0.00 0 0.00
273 Communication Eqpt at Bhopal SS 1000031374 85176290 18% TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 2 Included 0.00 0 0.00
274 Communication Eqpt at Bhopal SS 1000034950 85176990 18% ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 2 Included 0.00 0 0.00
275 Communication Eqpt at Bhopal SS 1000031381 85176290 18% TRIBUTARY INTERFACE-GIGABIT ETHERNET INTERFACES 10/100 MBPS WITH LAYER-2 SWITCHING (MINIMUM 2 NOS.) SET 1 Included 0.00 0 0.00
276 Communication Eqpt at Bhopal SS 1000026228 85176290 18% Equipment Cabinets For SDH EA 1 Included 0.00 0 0.00
277 Communication Eqpt at Bhopal SS 1000034998 85171890 18% VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 4 Included 0.00 0 0.00
278 Communication Eqpt at Bhopal SS 1000030942 85447090 18% 24F (DWSM) APPROACH FIBRE OPTIC CABLE INCLUDING ALL INSTALLATIONHARDWARE SET KM 1.000 Included 0.00 0 0.00
279 Communication Eqpt at Bhopal SS 1000023471 85372000 18% OPGW Fibre Optic Distribution Panel (FODP): Indoor Type: 96F EA 1 Included 0.00 0 0.00
280 Comm Eqpt Bhopal(Sterlite) Spare 1000023721 85176260 18% SFP S4.1 EA 1 Included 0.00 0 0.00
281 Comm Eqpt Bhopal(Sterlite) Spare 1000018706 85176990 18% S16.1 SFP EA 1 Included 0.00 0 0.00
Total Ex-works Price 0.00 0 0.00
Total GST as confirmed by Bidder 0.00
Total Ex-works Price 0.00
Total Type Test charges as per Schedule-7 Not Applicable
Total Ex-works Price including Type Test charges 0.00
Total GST Tax as confirmed by Bidder 0.00
Note : Specify amount of GST on the transaction between the Contractor and the Employer.
* In case the bidder leaves the cell for confirmation of the HSN code and/or GST rate “blank”, the HSN code and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Place : Printed Name :
TBCB/400kV/Rajgarh/SS01/G1/R Schedule - 1 Direct Total 0 Sole Bidder `
BO Total #REF! 0
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
(SCHEDULE OF RATES AND PRICES : EX-WORKS PRICES)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Plant and Equipment (including Mandatory Spares Parts) to be supplied, including Type Test Charges for Tests to be conducted. Direct
All Prices are in Indian Rupees. Bought-Out
SI. No. Item Description Unit Qty. Unit Ex-works price Total Ex-works price Mode of Transaction (Direct / Bought-out)
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
Total Ex-Works Price Direct 0.00 Direct
Total Ex-Works Price Bought Out 0.00
Total Ex-Works Price 0.00
Total Type Test charges as per Schedule-7 0.00 #REF! #REF!
Total Ex-works Price including Type Test charges 0.00 #REF! #REF!
Discount Sch-1 #REF! MPD Sch-1 #REF!
Dis Alert #REF!
Note : Specify amount of Excise Duty, Sales Tax/'VAT and other taxes payable on the transaction between the Contractor and the Employer and octroi/entry tax as applicable for destination site/state on all items of supply including bought-out finished items (to be identified in the Contract), which shall be dispatched directly from the sub-vendor’s works to the Employer’s site (sale-in-transit), separately in Schedule-5. Excise Duty, Sales tax and other levies for all the bought-out items are to be included in the EXW Price (Col. No. 5) only and not to be indicated in Schedule-5.
Place : Printed Name :
TBCB/400kV/Rajgarh/SS01/G1/R Schedule - 2 Dis
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC As per Lum-sum 0
(SCHEDULE OF RATES AND PRICES : FREIGHT & INSURANCE CHARGES) AS per Percent #REF!
As per lum-sum on Sch-2 0.00%
Bidder’s Name and Address (Sole Bidder) : To: As per Percent on Sch-2 #REF!
Contracts Services, 3rd Floor Total Discount #REF!
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
…….. …….. …….. …….. …….. …….. Sector-29, Multipackage Discount 0.00%
All Prices are in Indian Rupees. Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
SI. No. Description Unit Quantity Unit Freight & Insurance Charges Total Freight & Insurance Charges Unit Freight & Insurance Charges Total Freight & Insurance Charges Unit Freight & Insurance Charges Total Freight & Insurance Charges
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
Total F&I Price #REF!
Place : Printed Name :
TBCB/400kV/Rajgarh/SS01/G1/R Schedule - 2 Direct Total #REF! Sole Bidder `
BO Total #REF! 0
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
(SCHEDULE OF RATES AND PRICES)
Bidder’s Name and Address (Sole Bidder) : To:
Contracts Services, 3rd Floor
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Local Transportation, Insurance and other Incidental Services Direct
All Prices are in Indian Rupees. Bought-Out
SI. No. Activity Description Material Code Item Description Unit Qty. Unit F&I price Total F&I price
400/220kV Pachora SEZ PP (New)
1 420kV Bus Reactor 1000000705 125 MVAR, 420kV, 3-phase Bus Reactor excluding Insulating Oil EA 1 Included
2 420kV Bus Reactor 1000013947 Insulating Oil for 125 MVAR, 420kV 3-phase Bus Reactor SET 1 Included
3 420kV Bus Reactor 1000025218 On line insulating oil drying system (Cartridge type)(As per technicalspecification) EA 1 Included
4 420kV Line Reactor 1000006176 80 MVAR,420kV,3-phase Shunt Reactor excluding Insulating Oil EA 2 Included
5 420kV Line Reactor 1000014015 Insulating Oil for 80 MVAR,420kV ,3-phase Shunt Reactor withassociated NGR SET 2 Included
6 420kV Line Reactor 1000025212 Oil Storage Tank (20kL) EA 2 Included
7 420kV Line Reactor 1000030173 NEUTRAL GROUNDING REACTOR-W/O INSUL OIL EA 2 Included
8 420kV Line Reactor 1000028234 120kV Surge Arrester along with support structure & terminal SET 2 Included
9 420kV Line Reactor 1000025218 On line insulating oil drying system (Cartridge type)(As per technicalspecification) EA 2 Included
10 LT Transformer 1000004951 630kVA, 33/0.433kV, 3ph LT Transformer EA 2 Included
11 420kV Equipment 1000004501 420kV, 3150A, 63kA Circuit Breaker (3-Phase) without closing resistorand with Support Structure EA 11 Included
12 420kV Equipment 1000009713 Controlled Switching Device for 420 kV, 3-ph Circuit Breaker EA 4 Included
13 420kV Equipment 1000004463 420 kV, 3000A, 63KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 27 Included
14 420kV Equipment 1000004535 420 kV, 4400 pF Capacitive Voltage Transformer (1-Phase) EA 12 Included
15 420kV Equipment 1000004498 420kV, 3150A, 63KA, Isolator (3-phase)(Double Break) with one E/S EA 24 Included
16 420kV Equipment 1000020419 336kV Surge Arrester (1-phase) EA 24 Included
17 420kV Equipment 1000004401 420 kV, 1 phase Bus Post Insulator (except for Line Traps) EA 39 Included
18 420kV Equipment 1000004499 420kV, 3150A, 63KA Isolator (3-phase)(Double Break) with two E/S EA 2 Included
19 245kV Equipment 1000001683 245kV, 1600A, 50KA Circuit Breaker(3-Phase) with support structure EA 10 Included
20 245kV Equipment 1000028442 245kV, 3150A, 50KA Circuit Breaker(3-Phase) with support structure EA 1 Included
21 245kV Equipment 1000001684 245 kV, 1600A, 50KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 30 Included
22 245kV Equipment 1000001739 245 kV, 2500A, 50KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 3 Included
23 245kV Equipment 1000001689 245kV, 1600A, 50 KA, 3-phase DoubleBreak Isolator with two E/S EA 10 Included
24 245kV Equipment 1000001688 245kV, 1600A, 50 KA, 3-phase DoubleBreak Isolator with one E/S EA 10 Included
25 245kV Equipment 1000032777 245KV, 1600 A, 50KA, 3-PHASE, DOUBLE BREAK TANDEM ISOLATOR WITHOUT E/S EA 19 Included
26 245kV Equipment 1000051760 245KV, 3150A, 50KA, 3-PHASE DOUBLE BREAK ISOLATOR WITH TWO E/S EA 2 Included
27 245kV Equipment 1000020417 216kV Surge Arrester (1-phase) EA 27 Included
28 245kV Equipment 1000001772 245 kV, 4400pf Capacitive Voltage Transformer (1- Phase) EA 24 Included
29 245kV Equipment 1000001695 245 kV, 1 phase Bus Post Insulator (except for Line Traps) EA 132 Included
30 145kV Equipment 1000000945 145kV, 1250A, 31.5KA Circuit Breakers(1-Phase) with support structure EA 2 Included
31 145kV Equipment 1000000956 145kV, 1 phase Bus Post Insulators EA 2 Included
32 72.5kV Equipment 1000005036 72.5 kV, 1250A, 25 kA, 3-phase CircuitBreaker with support structure EA 1 Included
33 72.5kV Equipment 1000005061 72.5 kV, 50A, 25 kA, 1-Phase CurrentTransformer with 120% extended currentrating EA 3 Included
34 72.5kV Equipment 1000005048 72.5 kV Voltage Transformer (1- Phase) EA 3 Included
35 72.5kV Equipment 1000005070 72.5 kV, 400A, 25 KA, 3-Phase DoubleBreak Isolator with out E/S EA 1 Included
36 72.5kV Equipment 1000005030 72.5kV ,1 phase Bus Post Insulators EA 6 Included
37 36kV Equipment 1000020418 30kV Surge Arrester (1-Phase) EA 3 Included
38 36kV Equipment 1000002032 36kV, 1 phase Bus Post Insulators as per Technical Specification EA 3 Included
39 36kV Equipment 1000028100 36 kV, 3-Ph Horn Gap Fuse as per Technical Specification EA 1 Included
40 36kV Equipment 1000002087 36 kV, 400A, 25 KA, 3-Phase HDB Isolatorwithout E/S EA 1 Included
41 Erection Hardware - 420kV 1000011322 Erection Hardware for 400kV I type layout-Line bay as per technicalspecification SET 2 Included
42 Erection Hardware - 420kV 1000011327 Erection Hardware for 400kV I type layout-Transformer bay as pertechnical specification SET 3 Included
43 Erection Hardware - 420kV 1000011317 Erection Hardware for 400kV I type layout-Bus Reactor bay as pertechnical specification SET 1 Included
44 Erection Hardware - 420kV 1000011318 Erection Hardware for 400kV I type layout-Bus Work (For one diameter)as per technical specification SET 3 Included
45 Erection Hardware - 420kV 1000034966 ERECTION HARDWARE FOR 420 KV I TYPE LAYOUT-SWITCHABLE LINE REACTORSBAY INCLUDING NGR BYPASS ARRANGEMENT AS PER TECHNICAL SPECIFICATION SET 2 Included
46 Erection Hardware - 245kV 1000011261 Erection Hardware for 220kV layout (Double Main and TransferScheme)-Line Bay as per technical specification SET 6 Included
47 Erection Hardware - 245kV 1000011264 Erection Hardware for 220kV layout (Double Main and TransferScheme)-Transformer Bay as per technical specification SET 3 Included
48 Erection Hardware - 245kV 1000011265 Erection Hardware for 220kV layout (Double Main and TransferScheme)-Transfer Bus Coupler Bay as per technical specification SET 1 Included
49 Erection Hardware - 245kV 1000011253 Erection Hardware for 220kV layout (Double Main and TransferScheme)-Bus Coupler Bay as per technical specification SET 1 Included
50 Erection Hardware - 245kV 1000011255 Erection Hardware for 220kV layout (Double Main and TransferScheme)-Bus work (one Bay) as per technical specification SET 11 Included
51 Erection Hardware - 72.5kV 1000011348 Erection Hardware for the 72.5kV equipment for Tertiary loading as pertechnical specification SET 1 Included
52 Erection Hardware - 36kV 1000032412 ERECTION HARDWARE FOR AUXILIARY LT TRANSFORMER SET 1 Included
53 400kV Control & Relay Panel 1000002165 400kV Circuit Breaker Relay Panel with Auto Reclose (with Automation) EA 4 Included
54 400kV Control & Relay Panel 1000002163 400kV Circuit Breaker Relay Panel without Auto Reclose (withAutomation) EA 7 Included
55 400kV Control & Relay Panel 1000003398 400kV Line Protection Panel (with Automation) EA 2 Included
56 400kV Control & Relay Panel 1000004274 400kV Transformer Protection Panel (For both HV & MV side)-(withAutomation) EA 3 Included
57 400kV Control & Relay Panel 1000003407 400kV Reactor Protection Panel (with Automation) EA 1 Included
58 400kV Control & Relay Panel 1000002145 400kV Bus Bar Protection Panel (Duplicate)-(with Automation) SET 1 Included
59 220kV Control & Relay Panel 1000001168 220kV Circuit Breaker Relay Panel without Auto Reclose (withAutomation) EA 4 Included
60 220kV Control & Relay Panel 1000001170 220kV Circuit Breaker Relay Panel with Auto Reclose (with Automation) EA 7 Included
61 220kV Control & Relay Panel 1000001330 220kV Line Protection Panel (with Automation) EA 6 Included
62 220kV Control & Relay Panel 1000001166 220kV Bus Bar Protection Panel (Single)-(with Automation) SET 1 Included
63 Common Equipment - CRP 1000021642 Time synchronisation equipment EA 1 Included
64 Common Equipment - CRP 1000025391 Relay Test kit EA 1 Included
65 Substation Automation System 1000003408 Complete Substation automation System for 400kV Main bay as perTechnical Specification EA 8 Included
66 Substation Automation System 1000003410 Complete Substation automation System for 400kV Tie bay as perTechnical Specification EA 3 Included
67 Substation Automation System 1000049676 SUBSTATION AUTOMATION SYSTEM FOR 220KV LINE BAY AS PER TECHNICALSPECIFICATION EA 6 Included
68 Substation Automation System 1000049675 SUBSTATION AUTOMATION SYSTEM FOR 220KV TRANSFORMER BAY AS PERTECHNICAL SPECIFICATION EA 3 Included
69 Substation Automation System 1000038471 COMPLETE SUBSTATION AUTOMATION SYSTEM FOR 220KV TBC BAY ASPER TECHNICAL SPECIFICATION EA 1 Included
70 Substation Automation System 1000038470 COMPLETE SUBSTATION AUTOMATION SYSTEM FOR 220KV BUS COUPLER BAY AS PER TECHNICAL SPECIFICATION EA 1 Included
71 Substation Automation System 1000018700 Complete Substation automation System for controlling and monitoringof Auxilary System including BCUs as per technical specification SET 1 Included
72 PLCC Equipment at Pachora SEZ PP 1000004290 400kV,3150A,0.5mH ,63kA Line Trap EA 4 Included
73 PLCC Equipment at Pachora SEZ PP 1000004400 420 kV ,1 phase Bus Post Insulators for Line Traps EA 12 Included
74 PLCC Equipment at Pachora SEZ PP 1000010014 Coupling device for PLCC SET 2 Included
75 PLCC Equipment at Pachora SEZ PP 1000000046 Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 3 Included
76 PLCC Equipment at Pachora SEZ PP 1000010638 Digital Protection Coupler EA 2 Included
77 PLCC Equipment at Pachora SEZ PP 1000036908 HF CABLE 75 OHMS FOR PLCC KM 2.00 Included
78 PLCC Equipment at Pachora SEZ PP 1000002134 4wire telephone equipment EA 3 Included
79 PLCC Equipment at Pachora SEZ PP 1000017887 Analog Protection Coupler for PLCC EA 2 Included
80 PLCC Equipment at Pachora SEZ PP 1000001568 220kV,1600A,0.5mH ,50kA Line Trap EA 12 Included
81 PLCC Equipment at Pachora SEZ PP 1000001694 245 kV ,1 phase Bus Post Insulators for Line Traps EA 36 Included
82 PLCC Equipment at Pachora SEZ PP 1000025769 Testing & Maintenance equipment (print test kit only) for PLCC SET 1 Included
83 PLCC Equipment at Pachora SEZ PP 1000011082 EPAX (24/8) with 24 telephones, Cables etc. SET 1 Included
84 PLCC Equipment at Bhopal SS 1000010014 Coupling device for PLCC SET 2 Included
85 PLCC Equipment at Bhopal SS 1000000046 Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 3 Included
86 PLCC Equipment at Bhopal SS 1000017887 Analog Protection Coupler for PLCC EA 2 Included
87 PLCC Equipment at Bhopal SS 1000010638 Digital Protection Coupler EA 2 Included
88 PLCC Equipment at Bhopal SS 1000036908 HF CABLE 75 OHMS FOR PLCC KM 1.00 Included
89 PLCC Equipment at Bhopal SS 1000002134 4wire telephone equipment EA 2 Included
90 LT Switchgear 1000004313 415V Main Switchboard SET 1 Included
91 LT Switchgear 1000004303 415V AC Distribution Board (ACDB) as per Technical Specification SET 1 Included
92 LT Switchgear 1000004310 415V MLDB(along with 2 nos. 100 kVA Lighting transformer) SET 1 Included
93 LT Switchgear 1000004307 415V Emergency LDB(along with 1 no. 100kVA lighting transformer) SET 1 Included
94 LT Switchgear 1000001144 220V DCDB SET 2 Included
95 LT Switchgear 1000004754 48V DCDB SET 2 Included
96 Battery & Battery Charger 1000027411 48V Battery set SET 2 Included
97 Battery & Battery Charger 1000027377 220V Battery set SET 2 Included
98 Battery & Battery Charger 1000027575 220V Float Cum Boost Battery Charger EA 2 Included
99 Battery & Battery Charger 1000027578 48V Float Cum Boost Battery Charger EA 2 Included
100 DG Set 1000001893 250 kVA Diesel Generator along with control Panel SET 1 Included
101 Air Conditioning System 1000013502 High wall type split AC unit of 2 TR capacity EA 20 Included
102 Air Conditioning System 1000006285 Air conditioning system for Switchyard Panel Room of 9m length SET 1 Included
103 Air Conditioning System 1000006284 Air conditioning system for Switchyard Panel Room of 6m length SET 6 Included
104 Fire Protection System 1000012031 Pumping arrangement for HVW system & hydrant system, complete withall piping, valves, fittings,etc. inside pump house for FireProtection System of 400/220kV (New) Substation SET 1 Included
105 Fire Protection System 1000012036 Hydrant system, complete piping andaccessories etc. outside the Pump Housefor Fire Protection of 400/220kV (New)Substation SET 1 Included
106 Fire Protection System 1000012014 Fire Detection and Alarm System for Control Room Building(400kV) SET 1 Included
107 Fire Protection System 1000012019 Fire Detection and Alarm System for Switchyard Panel Room of 9 mlength SET 1 Included
108 Fire Protection System 1000012018 Fire Detection and Alarm System for Switchyard Panel Room of 6 mlength SET 6 Included
109 Fire Protection System 1000012069 HVW spray system, Hydrant system and complete U/G & O/G piping andaccessories etc. out side the pump house for 500MVA , 400KV/220/33kV, 3-phase Autotransformer SET 3 Included
110 Fire Protection System 1000012042 HVW spray system, Hydrant system and complete U/G & O/G piping andaccessories etc. out side the pump house for 125 MVAR, 420kV, 3 phaseBus Reactor SET 1 Included
111 Fire Protection System 1000012048 HVW spray system, Hydrant system and complete U/G & O/G piping andaccessories etc. out side the pump house for 80 MVAR, 420kV 3 phaseShunt Reactor SET 2 Included
112 Fire Protection System 1000012027 9litre water type Portable Fire extinguisher EA 20 Included
113 Fire Protection System 1000012022 4.5 kg CO2 type Portable Fire extinguisher EA 15 Included
114 Fire Protection System 1000049665 60 LITRE FOAM TYPE TROLLEY/WHEEL MOUNTED FIRE EXTINGUISHER SET 4 Included
115 Fire Protection System 1000012024 Fire Extinguisher Dry Chemical Powder Type(5 Kg) for control room. EA 8 Included
116 Illumination System 1000009647 Control room cum administrative building (400kV) illumination LOT 1 Included
117 Illumination System 1000028047 Fire fighting pumphouse building illimunation excluding conduit LS 1 Included
118 Illumination System 1000013796 Illumination System for switchyard panel room of 9 m length LS 1 Included
119 Illumination System 1000013795 Illumination System for switchyard panel room of 6 m length LS 6 Included
120 Illumination System 1000014547 Lighting Panel type ACP-2 as per technical specification EA 3 Included
121 Illumination System 1000020262 Sub Lighting panel (outdoor) type SLP (Switchyard and Street Lighting) EA 5 Included
122 Illumination System 1000038039 LIGHTING FIXTURE LED LUMINAIRES TYPE FL-1 AS PER TECH. SPECIFICATIONS EA 70 Included
123 Illumination System 1000038325 LIGHTING FIXTURE LED LUMINAIRES TYPE FL2 AS PER TECH. SPECIFICATIONS EA 140 Included
124 Illumination System 1000004952 63A, 415V : Interlocked switch socket outdoor Receptacle (type RP) asper technical specifications EA 2 Included
125 Illumination System 1000025538 Self Supported Aluminium Ladder as Per Technical Specification EA 1 Included
126 Illumination System 1000024515 Cartwheel Mounted Aluminium Ladder as Per Technical Specification EA 1 Included
127 Illumination System 1000001894 Outdoor Power Receptacle for oilfiltration unit (250A) EA 2 Included
128 Illumination System 1000038389 LED STREET LIGHT LUMINAIRE TYPE SL-L1 (= 45W)AS PER TECHNICALSPECIFICATION EA 40 Included
129 Illumination System 1000038397 TYPE L1 STREET LIGHTING POLE OF 6 METER AS PER TECHNICALSPECIFICATION. EA 40 Included
130 Illumination System 1000030151 Security Room Illumination including conduit LS 1 Included
131 Visual Monitoring System 1000025861 Visual Monitoring System for Watch & Ward SET 1 Included
132 Cables 1000032045 33KV GRADE HT XLPE CABLE ALONG WITH CLAMPS,LUGS, GLANDS AND STRAIGHTJOINTS. KM 2.00 Included
133 Cables 1000000444 1.1kV grade Power Cables (XLPEinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 Included
134 Cables 1000049673 1.1KV GRADE POWER & CONTROL CABLE (PVC) 400 KV LINE BAY ALONGWITHCLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC SET 2 Included
135 Cables 1000049488 1.1KV GRADE POWER & CONTROL CABLE (PVC) 400 KV TIE BAY ALONGWITHCLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC SET 3 Included
136 Cables 1000049487 1.1KV GRADE POWER & CONTROL CABLE (PVC) 400 KV ICT BAY ALONGWITHCLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC SET 3 Included
137 Cables 1000049486 1.1KV GRADE POWER & CONTROL CABLE (PVC) 400 KV BUS REACTOR BAYALONGWITH CLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC SET 1 Included
138 Cables 1000050124 1.1KV GRADE POWER & CONTROL CABLE (PVC) FOR 400 KV LINE REACTOR BAYALONGWITH CLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC SET 2 Included
139 Cables 1000049485 1.1KV GRADE POWER & CONTROL CABLE (PVC) 220 KV LINE BAY ALONGWITHCLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC SET 6 Included
140 Cables 1000049484 1.1KV GRADE POWER & CONTROL CABLE (PVC) 220 KV ICT BAY ALONGWITHCLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC SET 3 Included
141 Cables 1000049483 1.1KV GRADE POWER & CONTROL CABLE (PVC) 220 KV BUS COUPLER BAYALONGWITH CLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC SET 1 Included
142 Cables 1000049671 1.1KV GRADE POWER & CONTROL CABLE (PVC) 220 KV TRANSFER BUS COUPLERBAY ALONGWITH CLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC SET 1 Included
143 Cables 1000049482 1.1KV GRADE OTHER CABLES (NOT COVERED ABOVE) ALONGWITH CLAMPS, LUGS,GLANDS, STRAIGHT THROUGH JOINTS ETC LS 1 Included
144 400kV Gantry Structure 1000046563 GANTRY STRUCTURE PER DIAMETER- 400 KV ONE & HALF BREAKER LAYOUT SET 3 Included
145 220kV Gantry Structure 1000046562 GANTRY STRUCTURE FOR LINE BAY- 220 KV DOUBLE MAIN & TRANSFER LAYOUT SET 6 Included
146 220kV Gantry Structure 1000046567 GANTRY STRUCTURE FOR TRANSFORMER BAY- 220 KV DOUBLE MAIN & TRANSFERLAYOUT SET 3 Included
147 220kV Gantry Structure 1000046560 GANTRY STRUCTURE FOR BUS COUPLER BAY- 220 KV DOUBLE MAIN & TRANSFERLAYOUT SET 1 Included
148 220kV Gantry Structure 1000046565 GANTRY STRUCTURE FOR TRANSFER BUS COUPLER BAY- 220 KV DOUBLE MAIN &TRANSFER LAYOUT SET 1 Included
149 400kV Equipment Support Structure 1000049653 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV CT (1PH) EA 27 Included
150 400kV Equipment Support Structure 1000049654 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV CVT (1PH) EA 12 Included
151 400kV Equipment Support Structure 1000049657 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV ISOLATOR (3PH) EA 26 Included
152 400kV Equipment Support Structure 1000049655 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV CLASS SA (1PH) EA 24 Included
153 400kV Equipment Support Structure 1000049652 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV BPI (1PH) EA 39 Included
154 400kV Equipment Support Structure 1000049656 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV WAVE TRAP (1PH) EA 4 Included
155 220kV Equipment Support Structure 1000049647 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-220KV CT (1PH) EA 33 Included
156 220kV Equipment Support Structure 1000049648 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-220KV CVT (1PH) EA 24 Included
157 220kV Equipment Support Structure 1000049651 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-220KV ISOLATOR (3PH) EA 41 Included
158 220kV Equipment Support Structure 1000049649 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-220KV CLASS SA (1PH) EA 27 Included
159 220kV Equipment Support Structure 1000050459 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-220KV HIGH BPI (1PH)(BUS HEIGHT-8M APPROX.) SET 33 Included
160 220kV Equipment Support Structure 1000049646 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-220KV BPI (1PH) EA 99 Included
161 220kV Equipment Support Structure 1000049650 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-220KV WAVE TRAP (1PH) EA 12 Included
162 145kV Equipment Support Structure 1000050973 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-145KV BPI (1PH) EA 2 Included
163 72.5kV Equipment Support Structure 1000049659 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-72.5KV CT(1PH) EA 3 Included
164 72.5kV Equipment Support Structure 1000049660 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-72.5KV PT (1PH) EA 3 Included
165 72.5kV Equipment Support Structure 1000049661 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-72.5KV ISOLATOR (3PH) EA 1 Included
166 72.5kV Equipment Support Structure 1000049658 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-72.5KV BPI (1PH) EA 6 Included
167 36kV Equipment Support Structure 1000028542 STRUCTURE FOR-33KV H-TYPE POLE STRUCTURE EA 1 Included
168 Main Earthmat 1000032055 40 MM MS ROD FOR MAIN EARTHMAT KM 15.00 Included
169 Mandatory Spares-Bus Reactor 1000028245 Spare For 400kV Bus Reactor LS 1 Included
170 Mandatory Spares-Line Reactor 1000028266 Spares for 420kV Shunt Reactor LS 1 Included
171 Mandatory Spares Lumpsum 1000019918 Spares for 420kV Circuit Breaker LS 1 Included
172 Mandatory Spares Lumpsum 1000019919 Spares for 420kV Double break Isolator LS 1 Included
173 Mandatory Spares Lumpsum 1000024186 SPARES FOR 336KV SURGE ARRESTER LS 1 Included
174 Mandatory Spares Lumpsum 1000025943 Spare-420kV CVT 1 SET 1 Included
175 Mandatory Spares Lumpsum 1000025940 Spare-420kV BPI SET 1 Included
176 Mandatory Spares Lumpsum 1000025941 Spare-420kV CT 1 SET 1 Included
177 Mandatory Spares Lumpsum 1000025935 Spare-245kV Circuit Breaker SET 1 Included
178 Mandatory Spares Lumpsum 1000025936 Spare-245kV Isolator SET 1 Included
179 Mandatory Spares Lumpsum 1000025933 Spare-245kV CT SET 1 Included
180 Mandatory Spares Lumpsum 1000025934 Spare-245kV CVT SET 1 Included
181 Mandatory Spares Lumpsum 1000025932 Spare-245kV BPI SET 1 Included
182 Mandatory Spares Lumpsum 1000019912 Relay & protection Panels (with automation) LS 1 Included
183 Mandatory Spares Lumpsum 1000019927 Spares-Substation Automation System LS 1 Included
184 Mandatory Spares Lumpsum 1000025950 Spare-PLCC SET 1 Included
185 Mandatory Spares Lumpsum 1000019915 Spares for DG set LS 1 Included
186 Mandatory Spares Lumpsum 1000019914 Spares fpr 220V Battery Charger LS 1 Included
187 Mandatory Spares Lumpsum 1000019921 Spares fpr 48V Battery Charger LS 1 Included
188 Mandatory Spares Lumpsum 1000019913 Spares for 220V Batteries LS 1 Included
189 Mandatory Spares Lumpsum 1000019920 Spares for 48V Batteries LS 1 Included
190 Mandatory Spares Lumpsum 1000032289 SPARES FOFIRE PROTECTION SYSTEM SET 1 Included
191 Mandatory Spares Lumpsum 1000053851 SPARES FOR CLAMPS & CONNECTORS LOT 1 Included
192 Comm Eqpt at Pachora SEZ PP SUPPLY MAIN 1000031367 SDH EQUIPMENT (STM-16 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-BASEEQUIPMENT (COMMON CARDS, CROSS CONNECT/CONTROL CARDS, OPTICAL BASECARDS, POWER SUPPLY CARDS, POWER CABLING, OTHER HARDWARE ANDACCESSORIES INCLUDING SUB RACKS, PATCH CORD, DDF ETC FULLY EQUIPEDEXCLUDING OPTICAL INTERFACE & TRIBUTARY CARDS EA 1 Included
193 Comm Eqpt at Pachora SEZ PP SUPPLY MAIN 1000019316 Optical Line Interface card To support minimum 200 km EA 2 Included
194 Comm Eqpt at Pachora SEZ PP SUPPLY MAIN 1000031374 TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 2 Included
195 Comm Eqpt at Pachora SEZ PP SUPPLY MAIN 1000034950 ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 2 Included
196 Comm Eqpt at Pachora SEZ PP SUPPLY MAIN 1000031381 TRIBUTARY INTERFACE-GIGABIT ETHERNET INTERFACES 10/100 MBPS WITH LAYER-2 SWITCHING (MINIMUM 2 NOS.) SET 1 Included
197 Comm Eqpt at Pachora SEZ PP SUPPLY MAIN 1000026228 Equipment Cabinets For SDH EA 1 Included
198 Comm Eqpt at Pachora SEZ PP SUPPLY MAIN 1000028495 NMS- CRAFT TERMINAL-HARDWARE EA 1 Included
199 Comm Eqpt at Pachora SEZ PP SUPPLY MAIN 1000028265 Software for Craft Terminal EA 1 Included
200 Comm Eqpt at Pachora SEZ PP SUPPLY MAIN 1000034998 VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 4 Included
201 Comm Eqpt at Pachora SEZ PP SUPPLY MAIN 1000030942 24F (DWSM) APPROACH FIBRE OPTIC CABLE INCLUDING ALL INSTALLATIONHARDWARE SET KM 1.00 Included
202 Comm Eqpt at Pachora SEZ PP SUPPLY MAIN 1000023471 OPGW Fibre Optic Distribution Panel (FODP): Indoor Type: 96F EA 1 Included
203 Comm Eqpt at SEZ PP SUPPLY Spare 1000031369 SDH EQUIPMENT (STM-16 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-COMMONCARDS, CROSS-CONNECT/CONTROL CARDS, OPTICAL BASE CARD, POWER SUPPLYCARDS, POWER CABLING, OTHER HARDWARE & ACCESSORIES (EACH). SET 1 Included
204 Comm Eqpt at SEZ PP SUPPLY Spare 1000019316 Optical Line Interface card To support minimum 200 km EA 1 Included
205 Comm Eqpt at SEZ PP SUPPLY Spare 1000031374 TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 1 Included
206 Comm Eqpt at SEZ PP SUPPLY Spare 1000034950 ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 1 Included
207 Comm Eqpt at SEZ PP SUPPLY Spare 1000031381 TRIBUTARY INTERFACE-GIGABIT ETHERNET INTERFACES 10/100 MBPS WITH LAYER-2 SWITCHING (MINIMUM 2 NOS.) SET 1 Included
208 Comm Eqpt at SEZ PP SUPPLY Spare 1000034998 VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 1 Included
209 Comm Eqpt at SEZ PP SUPPLY Spare 1000031398 PRE CONNECTORIZED OPTICAL FIBER PATCH CORDS(10 MTRS) – PACK OF SIXPATCH CORDS SET 1 Included
210 Comm Eqpt at SEZ PP SUPPLY Spare 1000030942 24F (DWSM) APPROACH FIBRE OPTIC CABLE INCLUDING ALL INSTALLATIONHARDWARE SET KM 1.00 Included
211 Supply : PMU & associated items-Pachora 1000017518 PMU with GPS Clock (clock can be either internal or external) EA 2 Included
212 Supply : PMU & associated items-Pachora 1000022512 WAMS Hardware - Time System (GPS receiver) EA 2 Included
213 Supply : PMU & associated items-Pachora 1000022510 WAMS Hardware - Substation Grade Layer-3 LAN Switches with minimum 4 x10/100 Mbps Ethernet ports and 2 x 1 Gbps Ethernet ports EA 3 Included
214 Supply : PMU & associated items-Pachora 1000022487 WAMS Miscellaneous - Armored Fibre Optic Cable and associatedtermination (e.g. L2 Switch) for connecting PMU panels located indifferent control room of a station EA 1 Included
400kV Bhopal (Sterlite) extension
215 420kV Equipment 1000004535 420 kV, 4400 pF Capacitive Voltage Transformer (1-Phase) EA 6 Included
216 420kV Equipment 1000020419 336kV Surge Arrester (1-phase) EA 6 Included
217 420kV Equipment 1000004401 420 kV, 1 phase Bus Post Insulator (except for Line Traps) EA 14 Included
218 420kV Equipment 1000004501 420kV, 3150A, 63kA Circuit Breaker (3-Phase) without closing resistorand with Support Structure EA 4 Included
219 420kV Equipment 1000004463 420 kV, 3000A, 63KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 12 Included
220 420kV Equipment 1000004498 420kV, 3150A, 63KA, Isolator (3-phase)(Double Break) with one E/S EA 10 Included
221 PLCC Equipment 1000004400 420 kV ,1 phase Bus Post Insulators for Line Traps EA 12 Included
222 PLCC Equipment 1000004290 400kV,3150A,0.5mH ,63kA Line Trap EA 4 Included
223 400kV Control & Relay Panel 1000002165 400kV Circuit Breaker Relay Panel with Auto Reclose (with Automation) EA 4 Included
224 400kV Control & Relay Panel 1000003398 400kV Line Protection Panel (with Automation) EA 2 Included
225 400kV Control & Relay Panel 1000006843 Augmentation of existing 400kV bus bar protection scheme SET 1 Included
226 Substation Automation System 1000003409 Augmentation of Substation automation System for 400kV Main bay as perTechnical Specification EA 2 Included
227 Substation Automation System 1000003411 Augmentation of Substation automation System for 400kV Tie bay as perTechnical Specification EA 2 Included
228 Erection Hardware - 420kV 1000011318 Erection Hardware for 400kV I type layout-Bus Work (For one diameter)as per technical specification SET 2 Included
229 Erection Hardware - 420kV 1000011322 Erection Hardware for 400kV I type layout-Line bay as per technicalspecification SET 2 Included
230 Air Conditioning System 1000006284 Air conditioning system for Switchyard Panel Room of 6m length SET 1 Included
231 Fire Protection System 1000012018 Fire Detection and Alarm System for Switchyard Panel Room of 6 mlength SET 1 Included
232 Fire Protection System 1000012022 4.5 kg CO2 type Portable Fire extinguisher EA 2 Included
233 Illumination System 1000013795 Illumination System for switchyard panel room of 6 m length LS 1 Included
234 Illumination System 1000014547 Lighting Panel type ACP-2 as per technical specification EA 1 Included
235 Illumination System 1000020262 Sub Lighting panel (outdoor) type SLP (Switchyard and Street Lighting) EA 2 Included
236 Illumination System 1000038387 LED FLOOD LIGHT LUMINARIESTYPE FL-1 (150W) AS PER TECHNICALSPECIFICATION EA 10 Included
237 Illumination System 1000038325 LIGHTING FIXTURE LED LUMINAIRES TYPE FL2 AS PER TECH. SPECIFICATIONS EA 10 Included
238 Illumination System 1000038389 LED STREET LIGHT LUMINAIRE TYPE SL-L1 (= 45W)AS PER TECHNICALSPECIFICATION EA 10 Included
239 Illumination System 1000038397 TYPE L1 STREET LIGHTING POLE OF 6 METER AS PER TECHNICALSPECIFICATION. EA 10 Included
240 ACDB/DCDB 1000004304 415V ACDB (Extn.) SET 1 Included
241 ACDB/DCDB 1000001145 220V DCDB (Extn.) SET 1 Included
242 Cables 1000049673 1.1KV GRADE POWER & CONTROL CABLE (PVC) 400 KV LINE BAY ALONGWITHCLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC SET 2 Included
243 Cables 1000049488 1.1KV GRADE POWER & CONTROL CABLE (PVC) 400 KV TIE BAY ALONGWITHCLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC SET 2 Included
244 Cables 1000049482 1.1KV GRADE OTHER CABLES (NOT COVERED ABOVE) ALONGWITH CLAMPS, LUGS,GLANDS, STRAIGHT THROUGH JOINTS ETC LS 1 Included
245 Main Earthmat 1000032055 40 MM MS ROD FOR MAIN EARTHMAT KM 2.50 Included
246 400kV Gantry Structure 1000015954 Fabrication, galvanising and supply of Lattice Structures (MS Steel),to be designed during detailed engineering, for towers, beams andequipment support structure including pack plates / packwashers andgusset plates excluding fasteners and foundation bolts MT 87.00 Included
247 400kV Gantry Structure 1000011713 Fabrication, galvanising and supply of fasteners ( nuts, bolts andwashers ) including step bolts for lattice and pipe structures to bedesigned during detailed engineering MT 4.00 Included
248 400kV Gantry Structure 1000012373 Fabrication, galvanising and supply of foundation bolts including nuts,checknut and washers for lattice and pipe structures to be designedduring detailed engineering MT 1.00 Included
249 400kV Equipment Support Structure 1000049654 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV CVT (1PH) EA 6 Included
250 400kV Equipment Support Structure 1000049655 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV CLASS SA (1PH) EA 6 Included
251 400kV Equipment Support Structure 1000049652 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV BPI (1PH) EA 14 Included
252 400kV Equipment Support Structure 1000049656 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV WAVE TRAP (1PH) EA 4 Included
253 400kV Equipment Support Structure 1000049653 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV CT (1PH) EA 12 Included
254 400kV Equipment Support Structure 1000049657 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV ISOLATOR (3PH) EA 10 Included
255 Mandatory Spares 1000019918 Spares for 420kV Circuit Breaker LS 1 Included
256 Mandatory Spares 1000019919 Spares for 420kV Double break Isolator LS 1 Included
257 Mandatory Spares 1000024186 SPARES FOR 336KV SURGE ARRESTER LS 1 Included
258 Mandatory Spares 1000025943 Spare-420kV CVT 1 SET 1 Included
259 Mandatory Spares 1000025940 Spare-420kV BPI SET 1 Included
260 Mandatory Spares 1000025941 Spare-420kV CT 1 SET 1 Included
261 Mandatory Spares 1000019912 Relay & protection Panels (with automation) LS 1 Included
262 Mandatory Spares 1000019927 Spares-Substation Automation System LS 1 Included
263 Mandatory Spares 1000053851 SPARES FOR CLAMPS & CONNECTORS LOT 1 Included
264 Visual Monitoring System 1000030433 COLOR IP CAMERA, WITH PAN, TILT AND ZOOM FACILITIES, ALONGWITH ALLREQUIRED ITEMS, ACCESSORIES, LINE INTERFACE UNITS, FIBER PATCH CORDS,POWER SUPPLY UNITS, JUNCTION BOXES, CABLES, FIBER OPTIC CABLES, ETC.,AND INCLUDING INTEGRATION IN EXISTING HARDWARE AND SOFTWARE FORAUGMENTATION OF VISUAL MONITORING SYSTEM AS PER TECHNICALSPECIFICATION. SET 1 Included
265 Supply:PMU & assoc items-Bhopal 1000017518 PMU with GPS Clock (clock can be either internal or external) EA 2 Included
266 Supply:PMU & assoc items-Bhopal 1000022512 WAMS Hardware - Time System (GPS receiver) EA 2 Included
267 Supply:PMU & assoc items-Bhopal 1000022510 WAMS Hardware - Substation Grade Layer-3 LAN Switches with minimum 4 x10/100 Mbps Ethernet ports and 2 x 1 Gbps Ethernet ports EA 3 Included
268 Supply:PMU & assoc items-Bhopal 1000022487 WAMS Miscellaneous - Armored Fibre Optic Cable and associatedtermination (e.g. L2 Switch) for connecting PMU panels located indifferent control room of a station EA 1 Included
269 Communication Eqpt at Bhopal SS 1000031367 SDH EQUIPMENT (STM-16 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-BASEEQUIPMENT (COMMON CARDS, CROSS CONNECT/CONTROL CARDS, OPTICAL BASECARDS, POWER SUPPLY CARDS, POWER CABLING, OTHER HARDWARE ANDACCESSORIES INCLUDING SUB RACKS, PATCH CORD, DDF ETC FULLY EQUIPEDEXCLUDING OPTICAL INTERFACE & TRIBUTARY CARDS EA 1 Included
270 Communication Eqpt at Bhopal SS 1000018706 S16.1 SFP EA 4 Included
271 Communication Eqpt at Bhopal SS 1000023721 SFP S4.1 EA 4 Included
272 Communication Eqpt at Bhopal SS 1000019316 Optical Line Interface card To support minimum 200 km EA 2 Included
273 Communication Eqpt at Bhopal SS 1000031374 TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 2 Included
274 Communication Eqpt at Bhopal SS 1000034950 ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 2 Included
275 Communication Eqpt at Bhopal SS 1000031381 TRIBUTARY INTERFACE-GIGABIT ETHERNET INTERFACES 10/100 MBPS WITH LAYER-2 SWITCHING (MINIMUM 2 NOS.) SET 1 Included
276 Communication Eqpt at Bhopal SS 1000026228 Equipment Cabinets For SDH EA 1 Included
277 Communication Eqpt at Bhopal SS 1000034998 VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 4 Included
278 Communication Eqpt at Bhopal SS 1000030942 24F (DWSM) APPROACH FIBRE OPTIC CABLE INCLUDING ALL INSTALLATIONHARDWARE SET KM 1.00 Included
279 Communication Eqpt at Bhopal SS 1000023471 OPGW Fibre Optic Distribution Panel (FODP): Indoor Type: 96F EA 1 Included
280 Comm Eqpt Bhopal(Sterlite) Spare 1000023721 SFP S4.1 EA 1 Included
281 Comm Eqpt Bhopal(Sterlite) Spare 1000018706 S16.1 SFP EA 1 Included
Total F&I Price 0.00
Total F&I Price 0.00
Place : Printed Name :
TBCB/400kV/Rajgarh/SS01/G1/R Schedule - 3
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES ) AS per Percent #REF!
As per lum-sum on Sch-3 0.00%
Bidder’s Name and Address (Sole Bidder) : To: As per Percent on Sch-3 #REF!
Contracts Services, 3rd Floor Total Discount #REF!
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
…….. …….. …….. …….. …….. …….. Sector-29, Multipackage lum-sum 0.00%
Installation Charges : Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
All Prices are in Indian Rupees.
SI. No. Activity Description Service Code SAC (Service Accounting Codes) Whether SAC in column '2’ is confirmed. If not indicate applicable the SAC * Rate of GST applicable ( in %) Whether rate of GST in column ‘4’ is confirmed. If not indicate applicable rate of GST * Description Unit Quantity Unit Erection Charges Total Erection Charges Total GST as confirmed by Bidder Unit Erection Charges Total Erection Charges Unit Erection Charges Total Erection Charges
Est. of 400/220kV Kallam PS (New)
1 420kV Bus Reactor 100000059 998736 18% 125 MVAR, 420kV, 3-phase Bus Reactor excluding Insulating Oil EA 1 Included 0.00 0 0.00
2 420kV Bus Reactor 100000060 998736 18% Insulating Oil for 125 MVAR, 420kV 3-phase Bus Reactor SET 1 Included 0.00 0 0.00
3 420kV Bus Reactor 100000046 998736 18% On line insulating oil drying system (Cartridge type) (As per technical specification) EA 1 Included 0.00 0 0.00
4 420kV Line Reactor 100000053 998736 18% 80 MVAR,420kV,3-phase Shunt Reactor excluding Insulating Oil EA 2 Included 0.00 0 0.00
5 420kV Line Reactor 100000054 998736 18% Insulating Oil for 80 MVAR,420kV ,3-phase Shunt Reactor with associated NGR SET 2 Included 0.00 0 0.00
6 420kV Line Reactor 100000046 998736 18% On line insulating oil drying system (Cartridge type) (As per technical specification) EA 2 Included 0.00 0 0.00
7 420kV Line Reactor 100002497 998736 18% Neutral Grounding Reactor (NGR rated impedance) (excluding Insulating Oil) ( As per Technical Specification) EA 2 Included 0.00 0 0.00
8 420kV Line Reactor 100007950 998736 18% 120 kV Surge Arrester along with support structure & terminal connector EA 2 Included 0.00 0 0.00
9 LT Transformer 100000078 998736 18% 630kVA, 33/0.433kV, 3ph LT Transformer EA 2 Included 0.00 0 0.00
10 420kV Equipment 100000267 998736 18% 420kV, 3150A, 63kA Circuit Breaker(3-Phase) without closing resistor(with support structure) EA 11 Included 0.00 0 0.00
11 420kV Equipment 100000268 998736 18% Controlled Switching Device for 420 kV, 3-ph Circuit Breaker EA 4 Included 0.00 0 0.00
12 420kV Equipment 100000274 998736 18% 420 kV, 3000A, 63KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 27 Included 0.00 0 0.00
13 420kV Equipment 100000275 998736 18% 420 kV, 4400 pF Capacitive Voltage Transformer (1-Phase) EA 12 Included 0.00 0 0.00
14 420kV Equipment 100000328 998736 18% 336kV Surge Arrester (1-phase) EA 24 Included 0.00 0 0.00
15 420kV Equipment 100000340 998736 18% 420 kV Bus Post Insulator (Except for wave traps) EA 39 Included 0.00 0 0.00
16 420kV Equipment 100000287 998736 18% 420kV, 3150A, 63KA, Isolator (3-phase)(Double Break) with one E/S EA 24 Included 0.00 0 0.00
17 420kV Equipment 100000288 998736 18% 420kV, 3150A, 63KA Isolator (3-phase)(Double Break) with two E/S EA 2 Included 0.00 0 0.00
18 245kV Equipment 100003634 998736 18% 245 kV 1600A, 50KA Circuit Breakers (3-Phase) with support EA 10 Included 0.00 0 0.00
19 245kV Equipment 100001989 998736 18% 245 kV, 1600A, 50KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 30 Included 0.00 0 0.00
20 245kV Equipment 100000448 998736 18% 245 kV, 4400pf Capacitive Voltage Transformer (1- Phase) EA 24 Included 0.00 0 0.00
21 245kV Equipment 100002016 998736 18% 245kV, 1600A, 50 KA, 3-phase DoubleBreak Tandem Isolator without E/S EA 19 Included 0.00 0 0.00
22 245kV Equipment 100002014 998736 18% 245kV, 1600A, 50 KA, 3-phase DoubleBreak Isolator with one E/S EA 10 Included 0.00 0 0.00
23 245kV Equipment 100002013 998736 18% 245kV, 1600A, 50 KA, 3-phase DoubleBreak Isolator with two E/S EA 10 Included 0.00 0 0.00
24 245kV Equipment 100000484 998736 18% 216kV Surge Arrester (1-phase) EA 27 Included 0.00 0 0.00
25 245kV Equipment 100001907 998736 18% 245 kV,1 phase Bus Post Insulator (except for Line Traps) EA 132 Included 0.00 0 0.00
26 245kV Equipment 100011980 998736 18% 245KV, 3150 A, 50kA Circuit Breaker (3-Phase) with support structure EA 1 Included 0.00 0 0.00
27 245kV Equipment 100001993 998736 18% 245 kV, 2500A, 50KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 3 Included 0.00 0 0.00
28 245kV Equipment 100011982 998736 18% 245kV, 3150A, 50KA, 3-Phase Double Break Isolator with two E/S EA 2 Included 0.00 0 0.00
29 145kV Equipment 100001986 998736 18% 145kV, 1250A, 31.5KA Circuit Breakers(1-Phase) with support structure EA 2 Included 0.00 0 0.00
30 145kV Equipment 100001908 998736 18% 145kV ,1 phase Bus Post Insulators EA 2 Included 0.00 0 0.00
31 72.5kV Equipment 100000611 998736 18% 72.5 kV, 1250A, 25 kA, 3-phase CircuitBreaker with support structure EA 1 Included 0.00 0 0.00
32 72.5kV Equipment 100000623 998736 18% 72.5 kV, 50A, 25 kA, 1-Phase CurrentTransformer with 120% extended currentrating EA 3 Included 0.00 0 0.00
33 72.5kV Equipment 100000624 998736 18% 72.5 kV Voltage Transformer (1- Phase) EA 3 Included 0.00 0 0.00
34 72.5kV Equipment 100001909 998736 18% 72.5kV, Bus Post Insulator, 1-Phase EA 6 Included 0.00 0 0.00
35 72.5kV Equipment 100000626 998736 18% 72.5 kV, 400A, 25 KA, 3-Phase DoubleBreak Isolator with out E/S EA 1 Included 0.00 0 0.00
36 36kV Equipment 100000669 998736 18% 30kV Surge Arrester (1-Phase) EA 3 Included 0.00 0 0.00
37 36kV Equipment 100001935 998736 18% 36 kV, 400A, 25 KA, 3-Phase HDB Isolatorwithout E/S EA 1 Included 0.00 0 0.00
38 36kV Equipment 100000684 998736 18% 36kV, 1ph Bus post insulator SET 3 Included 0.00 0 0.00
39 36kV Equipment 100005735 998736 18% 33kV, 3 phase HG Fuse as per Technical Specification for feeder SET 1 Included 0.00 0 0.00
40 Erection Hardware - 420kV 100000329 998731 18% Erection Hardware for 400kV I type layout-Line bay as per specification SET 2 Included 0.00 0 0.00
41 Erection Hardware - 420kV 100000330 998731 18% Erection Hardware for 400kV I type layout-Transformer bay as per specification SET 3 Included 0.00 0 0.00
42 Erection Hardware - 420kV 100000331 998731 18% Erection Hardware for 400kV I type layout-Bus Reactor bay as per specification as per specification SET 1 Included 0.00 0 0.00
43 Erection Hardware - 420kV 100000192 998731 18% Erection Hardware for 765kV I type layout-Bus Work (For one diameters) as per specification SET 3 Included 0.00 0 0.00
44 Erection Hardware - 420kV 100004473 998731 18% Erection Hardware for 420 kV I type layout-Switchable Line Reactors bay including NGR bypass arrangement as per technicalspecification SET 2 Included 0.00 0 0.00
45 Erection Hardware - 245kV 100000485 998731 18% Erection Hardware for 220kV layout (Double Main and Transfer Scheme as per SLD)-Line Bay as per specification SET 6 Included 0.00 0 0.00
46 Erection Hardware - 245kV 100000486 998731 18% Erection Hardware for 220kV layout (Double Main and Transfer Scheme as per SLD)-Transformer Bay as per specification SET 3 Included 0.00 0 0.00
47 Erection Hardware - 245kV 100000487 998731 18% Erection Hardware for 220kV layout (Double Main and Transfer Scheme as per SLD)-Transfer Bus Coupler Bay as per specification SET 1 Included 0.00 0 0.00
48 Erection Hardware - 245kV 100000488 998731 18% Erection Hardware for 220kV layout (Double Main and Transfer Scheme as per SLD)-Bus Coupler Bay as per specification SET 1 Included 0.00 0 0.00
49 Erection Hardware - 245kV 100000489 998731 18% Erection Hardware for 220kV layout (Double Main and Transfer Scheme as per SLD)-Bus work (one Bay) as per specification SET 11 Included 0.00 0 0.00
50 Erection Hardware - 72.5kV 100002036 998731 18% Erection Hardware for the 72.5kV equipment for Tertiary loading as per technical specification SET 1 Included 0.00 0 0.00
51 Erection Hardware - 36kV 100002037 998731 18% Erection Hardware for the 33kV equipment for SEB supply as per technical specification SET 1 Included 0.00 0 0.00
52 400kV Control & Relay Panel 100000728 998736 18% 400kV Circuit Breaker Relay Panel with Auto Reclose (with Automation) EA 4 Included 0.00 0 0.00
53 400kV Control & Relay Panel 100000729 998736 18% 400kV Circuit Breaker Relay Panel without Auto Reclose (with Automation) EA 7 Included 0.00 0 0.00
54 400kV Control & Relay Panel 100000730 998736 18% 400kV Line Protection Panel (with Automation) EA 2 Included 0.00 0 0.00
55 400kV Control & Relay Panel 100000731 998736 18% 400kV Transformer Protection Panel (For both HV & MV side)-(with Automation) EA 3 Included 0.00 0 0.00
56 400kV Control & Relay Panel 100000732 998736 18% 400kV Reactor Protection Panel (with Automation) EA 1 Included 0.00 0 0.00
57 400kV Control & Relay Panel 100000733 998736 18% 400kV Bus Bar Protection Panel (Duplicate)-(with Automation) SET 1 Included 0.00 0 0.00
58 220kV Control & Relay Panel 100000736 998736 18% 220kV Circuit Breaker Relay Panel with Auto Reclose (with Automation) EA 7 Included 0.00 0 0.00
59 220kV Control & Relay Panel 100000737 998736 18% 220kV Circuit Breaker Relay Panel without Auto Reclose (with Automation) EA 4 Included 0.00 0 0.00
60 220kV Control & Relay Panel 100000741 998736 18% 220kV Bus Bar Protection Panel (Single)-(with Automation) SET 1 Included 0.00 0 0.00
61 220kV Control & Relay Panel 100000804 998736 18% 220kV Simplex Line Protection Panel EA 6 Included 0.00 0 0.00
62 Common Equipment - CRP 100001891 998736 18% Time synchronisation equipment EA 1 Included 0.00 0 0.00
63 Substation Automation System 100000771 998736 18% Complete Substation automation System for 400kV Main bay as per Technical Specification EA 8 Included 0.00 0 0.00
64 Substation Automation System 100000777 998736 18% Complete Substation automation System for 400kV Tie bay as per Technical Specification EA 3 Included 0.00 0 0.00
65 Substation Automation System 100000783 998736 18% Complete Substation automation System for controlling and monitoring of Auxilary System including BCUs as per technicalspecification SET 1 Included 0.00 0 0.00
66 Substation Automation System 100008246 998736 18% Substation Automation System for 220kV Line bay as per Technical Specification EA 6 Included 0.00 0 0.00
67 Substation Automation System 100008247 998736 18% Substation Automation System for 220kV Transformer bay as per Technical Specification EA 3 Included 0.00 0 0.00
68 Substation Automation System 100004970 998736 18% Complete Substation automation System for 220kV TBC bay as per Technical Specification EA 1 Included 0.00 0 0.00
69 Substation Automation System 100004971 998736 18% Complete Substation automation System for 220kV Bus Coupler bay as perTechnical Specification EA 1 Included 0.00 0 0.00
70 PLCC Equipment at Pachora SEZ PP 100000883 998734 18% 420 kV ,1 phase Bus Post Insulators for Line Traps EA 12 Included 0.00 0 0.00
71 PLCC Equipment at Pachora SEZ PP 100002042 998734 18% 400kV,3150A,0.5mH ,63kA Line Trap EA 4 Included 0.00 0 0.00
72 PLCC Equipment at Pachora SEZ PP 100000886 998734 18% Coupling device for PLCC EA 2 Included 0.00 0 0.00
73 PLCC Equipment at Pachora SEZ PP 100000888 998734 18% Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 3 Included 0.00 0 0.00
74 PLCC Equipment at Pachora SEZ PP 100000890 998734 18% Protection Coupler (Analog) EA 2 Included 0.00 0 0.00
75 PLCC Equipment at Pachora SEZ PP 100000891 998734 18% Digital Protection Coupler EA 2 Included 0.00 0 0.00
76 PLCC Equipment at Pachora SEZ PP 100000892 998734 18% EPAX (24/8) with 24 telephones, Cables etc. SET 1 Included 0.00 0 0.00
77 PLCC Equipment at Pachora SEZ PP 100003435 998734 18% 4-WIRE TELEPHONE EA 3 Included 0.00 0 0.00
78 PLCC Equipment at Pachora SEZ PP 100002048 998734 18% 220kV,1600A,0.5mH ,50kA Line Trap EA 12 Included 0.00 0 0.00
79 PLCC Equipment at Pachora SEZ PP 100003517 998734 18% HF CABLE FOR PLCC-75 OHM (KM) KM 2.000 Included 0.00 0 0.00
80 PLCC Equipment at Pachora SEZ PP 100000884 998734 18% 245 kV ,1 phase Bus Post Insulators for Line Traps EA 36 Included 0.00 0 0.00
81 PLCC Equipment at Bhopal SS 100000886 998734 18% Coupling device for PLCC EA 2 Included 0.00 0 0.00
82 PLCC Equipment at Bhopal SS 100000888 998734 18% Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 3 Included 0.00 0 0.00
83 PLCC Equipment at Bhopal SS 100000890 998734 18% Protection Coupler (Analog) EA 2 Included 0.00 0 0.00
84 PLCC Equipment at Bhopal SS 100000891 998734 18% Digital Protection Coupler EA 2 Included 0.00 0 0.00
85 PLCC Equipment at Bhopal SS 100003517 998734 18% HF CABLE FOR PLCC-75 OHM (KM) KM 1.000 Included 0.00 0 0.00
86 PLCC Equipment at Bhopal SS 100003435 998734 18% 4-WIRE TELEPHONE EA 2 Included 0.00 0 0.00
87 LT Switchgear 100000894 998736 18% 415V Main Switchboard SET 1 Included 0.00 0 0.00
88 LT Switchgear 100000895 998736 18% AC Distribution Board (ACDB) SET 1 Included 0.00 0 0.00
89 LT Switchgear 100000899 998736 18% 415V Emergency LDB(along with 1 no. 100kVA lighting transformer) SET 1 Included 0.00 0 0.00
90 LT Switchgear 100002064 998731 18% 415V MLDB(along with 2 nos. 100 kVA Lighting transformer) SET 1 Included 0.00 0 0.00
91 LT Switchgear 100000902 998736 18% 220V DCDB SET 2 Included 0.00 0 0.00
92 LT Switchgear 100000905 998736 18% 48V DCDB SET 2 Included 0.00 0 0.00
93 Battery & Battery Charger 100006970 998736 18% 220V Float cum Boost battery Charger . EA 2 Included 0.00 0 0.00
94 Battery & Battery Charger 100012369 998736 18% Erection of 48V Battery Chargers as per TS LS 2 Included 0.00 0 0.00
95 Battery & Battery Charger 100007271 998734 18% 48 V VRLA Battery Bank SET 2 Included 0.00 0 0.00
96 Battery & Battery Charger 100016318 998736 18% 220V Battery set SET 2 Included 0.00 0 0.00
97 DG Set 100000957 998736 18% 250 kVA Diesel Generator along with control Panel SET 1 Included 0.00 0 0.00
98 Air Conditioning System 100000960 995463 18% High wall type split AC unit of 2 TR capacity EA 20 Included 0.00 0 0.00
99 Air Conditioning System 100001882 995463 18% Air conditioning system for Switchyard Panel Room of 6m length SET 6 Included 0.00 0 0.00
100 Air Conditioning System 100001881 995463 18% Air conditioning system for Switchyard Panel Room of 9m length SET 1 Included 0.00 0 0.00
101 Fire Protection System 100000967 998736 18% Pumping arrangement for HVW system & hydrant system, complete with all piping, valves, fittings,etc. inside pump house for FireProtection System of 400/220kV (New) Substation SET 1 Included 0.00 0 0.00
102 Fire Protection System 100000970 998736 18% Hydrant system, complete piping andaccessories etc. outside the Pump Housefor Fire Protection of 400/220kV (New)Substation SET 1 Included 0.00 0 0.00
103 Fire Protection System 100000972 998736 18% 9litre water type Portable Fire extinguisher EA 20 Included 0.00 0 0.00
104 Fire Protection System 100000975 995461 18% 4.5 kg CO2 type Portable Fire extinguisher EA 15 Included 0.00 0 0.00
105 Fire Protection System 100002752 998736 18% 5Kg dry chemical powered type Portable Fire extinguisher EA 8 Included 0.00 0 0.00
106 Fire Protection System 100001010 998736 18% HVW spray system, Hydrant system and complete U/G & O/G piping and accessories etc. out side the pump house for 125 MVAR, 420kV, 3phase Bus Reactor SET 1 Included 0.00 0 0.00
107 Fire Protection System 100000983 998736 18% HVW spray system, Hydrant system and complete U/G & O/G piping and accessories etc. out side the pump house for 500MVA ,400KV/220/33 kV, 3-phase Autotransformer SET 3 Included 0.00 0 0.00
108 Fire Protection System 100002062 995461 18% Fire Detection and Alarm System for Switchyard Panel Room of 6 m length SET 6 Included 0.00 0 0.00
109 Fire Protection System 100008260 998736 18% 60 litre foam type Trolley/Wheel mounted Fire extinguisher EA 4 Included 0.00 0 0.00
110 Fire Protection System 100002056 995461 18% Fire Detection and Alarm System for Control Room Building(400kV) SET 1 Included 0.00 0 0.00
111 Fire Protection System 100001871 995461 18% Fire Detection and Alarm System for Switchyard Panel Room of 9 m length SET 1 Included 0.00 0 0.00
112 Fire Protection System 100001005 998736 18% HVW spray system, Hydrant system and complete U/G & O/G piping and accessories etc. out side the pump house for 80 MVAR, 420kV 3phase Shunt Reactor SET 2 Included 0.00 0 0.00
113 Illumination System 100001887 998739 18% Control room cum administrative building (400kV) illumination. LOT 1 Included 0.00 0 0.00
114 Illumination System 100002750 998739 18% Fire fighting pumphouse building and DG set area illimunation as per Tech. Spec. SET 1 Included 0.00 0 0.00
115 Illumination System 100001116 998739 18% Illumination System for switchyard panel room of 6 m length SET 6 Included 0.00 0 0.00
116 Illumination System 100001021 995461 18% Lighting Panel type ACP-2 as per technical specification EA 3 Included 0.00 0 0.00
117 Illumination System 100001024 998731 18% Sub Lighting panel (outdoor) type SLP (Switchyard and Street Lighting) EA 5 Included 0.00 0 0.00
118 Illumination System 100004931 998731 18% LED Flood Light Luminaries Type FL-2 (250W) as per technical specification EA 140 Included 0.00 0 0.00
119 Illumination System 100004930 998731 18% LED Flood Light Luminaries Type-FL-1 as per technical specification EA 70 Included 0.00 0 0.00
120 Illumination System 100001052 998731 18% 63A, 415V : Interlocked switch socket outdoor Receptacle (type RP) as per technical specifications EA 2 Included 0.00 0 0.00
121 Illumination System 100001885 998739 18% Outdoor Power Receptacle for oilfiltration unit (250A) EA 2 Included 0.00 0 0.00
122 Illumination System 100004932 998731 18% LED Street Light Luminaire TYPE SL-L1 (= 45W)as per technical specification EA 40 Included 0.00 0 0.00
123 Illumination System 100004934 998731 18% Type L1 Street Lighting Pole of 6 meter as per technical specification. EA 40 Included 0.00 0 0.00
124 Illumination System 100001115 998739 18% Illumination System for switchyard panel room of 9 m length SET 1 Included 0.00 0 0.00
125 Illumination System 100002487 998731 18% Security Room Illumination including conduit LS 1 Included 0.00 0 0.00
126 Visual Monitoring System 100000869 998736 18% Visual monitoring system for watch & ward SET 1 Included 0.00 0 0.00
127 Cables 100003094 998736 18% 33KV GRADE HT XLPE CABLE ALONG WITH CLAMPS,LUGS, GLANDS AND STRAIGHT JOINTS. KM 2.000 Included 0.00 0 0.00
128 Cables 100002180 998736 18% 1.1kV grade Power Cables (XLPEinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 Included 0.00 0 0.00
129 Cables 100008198 998736 18% 1.1kV Grade Power & Control Cable (PVC) 400 kV Tie Bay alongwith clamps, lugs, glands, straight through joints etc SET 3 Included 0.00 0 0.00
130 Cables 100008197 998736 18% 1.1kV Grade Power & Control Cable (PVC) 400 kV Bus reactor Bay alongwith clamps, lugs, glands, straight through joints etc SET 1 Included 0.00 0 0.00
131 Cables 100008196 998736 18% 1.1kV Grade Power & Control Cable (PVC) 400 kV ICT Bay alongwith clamps, lugs, glands, straight through joints etc SET 3 Included 0.00 0 0.00
132 Cables 100008202 998736 18% 1.1kV Grade Power & Control Cable (PVC) 220 kV Line Bay alongwith clamps, lugs, glands, straight through joints etc SET 6 Included 0.00 0 0.00
133 Cables 100008199 998736 18% 1.1kV Grade Power & Control Cable (PVC) 220 kV ICT Bay alongwith clamps, lugs, glands, straight through joints etc SET 3 Included 0.00 0 0.00
134 Cables 100008200 998736 18% 1.1kV Grade Power & Control Cable (PVC) 220 kV Bus Coupler Bay alongwith clamps, lugs, glands, straight through joints etc SET 1 Included 0.00 0 0.00
135 Cables 100008239 998736 18% 1.1KV GRADE POWER & CONTROL CABLE (PVC) 400 KV LINE BAY ALONGWITH CLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC SET 2 Included 0.00 0 0.00
136 Cables 100008241 998736 18% 1.1KV GRADE POWER & CONTROL CABLE (PVC) 220 KV TRANSFER BUS COUPLER BAY ALONGWITH CLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC SET 1 Included 0.00 0 0.00
137 Cables 100008270 998736 18% 1.1KV GRADE OTHER CABLES (NOT COVERED ABOVE) ALONGWITH CLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC LS 1 Included 0.00 0 0.00
138 Cables 100008592 998736 18% 1.1KV GRADE POWER & CONTROL CABLE (PVC) FOR 400 KV LINE REACTOR BAY ALONGWITH CLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC. SET 2 Included 0.00 0 0.00
139 400kV Gantry Structure 100007634 998731 18% Gantry structure per diameter- 400 kV One & half breaker layout SET 3 Included 0.00 0 0.00
140 220kV Gantry Structure 100007635 998731 18% Gantry structure for line bay- 220 kV Double Main & Transfer Layout SET 6 Included 0.00 0 0.00
141 220kV Gantry Structure 100007636 998731 18% Gantry structure for transformer bay- 220 kV Double Main & Transfer Layout SET 3 Included 0.00 0 0.00
142 220kV Gantry Structure 100007637 998731 18% Gantry structure for bus coupler bay- 220 kV Double Main & Transfer Layout SET 1 Included 0.00 0 0.00
143 220kV Gantry Structure 100007638 998731 18% Gantry structure for transfer bus coupler bay- 220 kV Double Main & Transfer Layout SET 1 Included 0.00 0 0.00
144 400kV Equipment Support Structure 100008220 995455 18% Equipment Structure including Foundation bolt-400kV CVT (1Ph) EA 12 Included 0.00 0 0.00
145 400kV Equipment Support Structure 100008221 995455 18% Equipment Structure including Foundation bolt-400kV Isolator (3Ph) EA 26 Included 0.00 0 0.00
146 400kV Equipment Support Structure 100008222 995455 18% Equipment Structure including Foundation bolt-400kV class SA (1Ph) EA 24 Included 0.00 0 0.00
147 400kV Equipment Support Structure 100008223 995455 18% Equipment Structure including Foundation bolt-400kV BPI (1Ph) EA 39 Included 0.00 0 0.00
148 400kV Equipment Support Structure 100008224 995455 18% Equipment Structure including Foundation bolt-400kV Wave Trap (1Ph) EA 4 Included 0.00 0 0.00
149 400kV Equipment Support Structure 100008219 995455 18% Equipment Structure including Foundation bolt-400kV CT (1Ph) EA 27 Included 0.00 0 0.00
150 220kV Equipment Support Structure 100008226 995455 18% Equipment Structure including Foundation bolt-220kV CVT (1Ph) EA 24 Included 0.00 0 0.00
151 220kV Equipment Support Structure 100008227 995455 18% Equipment Structure including Foundation bolt-220kV Isolator (3Ph) EA 41 Included 0.00 0 0.00
152 220kV Equipment Support Structure 100008228 995455 18% Equipment Structure including Foundation bolt-220kV class SA (1Ph) EA 27 Included 0.00 0 0.00
153 220kV Equipment Support Structure 100008229 995455 18% Equipment Structure including Foundation bolt-220kV Wave Trap (1Ph) EA 12 Included 0.00 0 0.00
154 220kV Equipment Support Structure 100008230 995455 18% Equipment Structure including Foundation bolt-220kV BPI (1Ph) EA 99 Included 0.00 0 0.00
155 220kV Equipment Support Structure 100008640 995455 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-220KV HIGH BPI (1PH) (BUS HEIGHT-8M APPROX.) SET 33 Included 0.00 0 0.00
156 220kV Equipment Support Structure 100008225 995455 18% Equipment Structure including Foundation bolt-220kV CT (1Ph) EA 33 Included 0.00 0 0.00
157 145kV Equipment Support Structure 100010821 995455 18% Equipment Structure including Foundation bolt-145kV BPI (1Ph) EA 1 Included 0.00 0 0.00
158 72.5kV Equipment Support Structure 100008231 995455 18% Equipment Structure including Foundation bolt-72.5kV CT(1Ph) EA 3 Included 0.00 0 0.00
159 72.5kV Equipment Support Structure 100008232 995455 18% Equipment Structure including Foundation bolt-72.5kV PT (1Ph) EA 3 Included 0.00 0 0.00
160 72.5kV Equipment Support Structure 100008233 995455 18% Equipment Structure including Foundation bolt-72.5kV Isolator (3Ph) EA 1 Included 0.00 0 0.00
161 72.5kV Equipment Support Structure 100008234 995455 18% Equipment Structure including Foundation bolt-72.5kV BPI (1Ph) EA 6 Included 0.00 0 0.00
162 36kV Equipment Support Structure 100001672 995455 18% Erection of 33kV ouble Pole Structure including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 1 Included 0.00 0 0.00
163 Main Earthmat 100003103 998731 18% 40 mm MS rod for Main Earthmat KM 15.000 Included 0.00 0 0.00
164 Communication Eqpt at Pachora SEZService 100002812 998734 18% SDH Equipment (STM-16 MADM upto 5 MSP protected directions)-Base Equipment (Common cards, Cross Connect/control cards, optical basecards, power supply cards, power cabling, other hardware and accessories including sub racks, patch cord, DDF etc fully equipedexcluding optical interface & Tributary cards EA 1 Included 0.00 0 0.00
165 Communication Eqpt at Pachora SEZService 170000437 998734 18% Optical Line Interface Card (to support minimum 200 Kms) for STM-16 EA 2 Included 0.00 0 0.00
166 Communication Eqpt at Pachora SEZService 100002825 998734 18% Tributary interface- E1 interface (Minimum 16 nos.) SET 2 Included 0.00 0 0.00
167 Communication Eqpt at Pachora SEZService 170000550 998336 18% Ethernet Interface 10/100 Base T with Layer-2 switching (Min 8 Interfaces per card) EA 2 Included 0.00 0 0.00
168 Communication Eqpt at Pachora SEZService 100002829 998734 18% Tributary interface-Gigabit Ethernet Interfaces 10/100 Mbps with Layer -2 Switching (minimum 2 nos.) SET 1 Included 0.00 0 0.00
169 Communication Eqpt at Pachora SEZService 170000375 998734 18% Equipment Cabinets-For SDH Equipments EA 1 Included 0.00 0 0.00
170 Communication Eqpt at Pachora SEZService 170000376 998734 18% NMS-Craft Terminal-Hardware EA 1 Included 0.00 0 0.00
171 Communication Eqpt at Pachora SEZService 170000377 998734 18% NMS-Craft Terminal-Software EA 1 Included 0.00 0 0.00
172 Communication Eqpt at Pachora SEZService 170000551 998336 18% VOIP telephone instrument with one common switch (min. 8 port) EA 4 Included 0.00 0 0.00
173 Communication Eqpt at Pachora SEZService 100002882 998336 18% Fibre Optic Approach cabling: Including installation hardware like ties/clips/cleats, conduits, ducts, supports, fittings,accessories etc.: 24 Fibre KM 1.000 Included 0.00 0 0.00
174 Communication Eqpt at Pachora SEZService 170000356 998336 18% Fibre Optic Distribution Panel (FODP): Indoor Type: FC Coupling and mounted on ETSI 19" rack or slimline rack: Type 2 (96 Fibre) EA 1 Included 0.00 0 0.00
175 Civil Works 100004518 995433 18% Excavation in all kind of soil including rock for all leads and lifts, backfilling, disposal of surplus earth within a lead up to2Km as per technical specification. The surplus earth shall be roughly graded . M3 19331.000 Included 0.00 0 0.00
176 Civil Works 100011662 995433 18% Excavation in hard rock which require blasting (including chemical blasting and rock excavated using specialized tools) for allfoundation works including stacking, measuring, disposal etc.for all leads and lifts as per technical specification. M3 13750.000 Included 0.00 0 0.00
177 Civil Works 100001325 995454 18% Providing and laying of Plain Cement Concrete (PCC) (1:4:8) M3 1438.000 Included 0.00 0 0.00
178 Civil Works 100001326 995454 18% Providing and laying of Plain Cement Concrete (PCC) (1:2:4) M3 289.000 Included 0.00 0 0.00
179 Civil Works 100001327 995454 18% Providing and laying of Reinforced Cement Concrete M25 mix including pre cast, shuttering, Grouting of pockets & underpinning butexcluding steel reinforcement M3 8674.000 Included 0.00 0 0.00
180 Civil Works 100001328 995454 18% Providing and laying Plain Cement Concrete 1:5:10 (1 cement : 5 sand : 10 brick aggregate) M3 4500.000 Included 0.00 0 0.00
181 Civil Works 100001329 995454 18% Steel Reinforcement MT 557.000 Included 0.00 0 0.00
182 Civil Works 100001331 995455 18% Misc. Structural steel including rails, embedments, edge protection angles, gratings etc. but excluding the reinforcement steel andsteel for lattice and pipe structures. MT 187.000 Included 0.00 0 0.00
183 Civil Works 100001714 995428 18% Stone spreading in switchyard excluding PCC M2 60000.000 Included 0.00 0 0.00
184 Civil Works 100001713 995424 18% Antiweed treatment M2 60000.000 Included 0.00 0 0.00
185 Civil Works 100001330 995428 18% Stone filling (40 mm size) for transformer/Reactor foundation M3 101.000 Included 0.00 0 0.00
186 Civil Works 100008110 995421 18% 3.75m wide Bitumen road with earthen shoulder including 100 mm dia RCC Hume Pipe @ 100 metre interval as per drawing and TS (as perDSR item no 16.35 and 16.30.1) and including 225 mm thick WBM in three equal layers of 75 mm each as per CPWD specification. M2 6375.000 Included 0.00 0 0.00
187 Civil Works 100002581 995421 18% Construction of rail cum road as per drawing including all item such as excavation,compactions, rolling watering, WBM etc. butexcluding concrete reinforcement and structural steel-Section having two rails M2 189.000 Included 0.00 0 0.00
188 Civil Works 100002580 995421 18% Construction of rail cum road as per drawing including all item such as excavation,compactions, rolling watering, WBM etc. butexcluding concrete reinforcement and structural steel-Section having four rails M2 231.000 Included 0.00 0 0.00
189 Civil Works 100003114 995454 18% External finishing / painting of fire wall (water proofing cement paint) (DSR 13.44.1) M2 400.000 Included 0.00 0 0.00
190 Civil Works 100008611 995477 18% Swtichyard fencing: Providing and fixing fencing of GI barbed wire consisting of galvanized MS tubular posts at 3 m intervals; GIbarded wire shall run horizontally from post to post at a spacing of 300 mm (vertically) and a cross formation in each panel,complete as per technical specification and drawing. M 200.000 Included 0.00 0 0.00
191 Civil Works 100001392 995455 18% Switchyard Gate excluding Concrete EA 2 Included 0.00 0 0.00
192 Civil Works 100001735 995462 18% RCC culverts and cable trench crossings including supplying and laying hume pipe 250mm dia of grade (NP-3) excluding concrete as perspecification. M 50.000 Included 0.00 0 0.00
193 Civil Works 100001736 995462 18% RCC culverts and cable trench crossings including supplying and laying hume pipe 300mm dia of grade (NP-3) excluding concrete as perspecification. M 50.000 Included 0.00 0 0.00
194 Civil Works 100001737 995462 18% RCC culverts and cable trench crossings including supplying and laying hume pipe 450mm dia of grade (NP-3) excluding concrete as perspecification. M 50.000 Included 0.00 0 0.00
195 Civil Works 100001405 995462 18% Supplying & laying hume pipe of grade (NP-3) excluding reinforcement and concrete as per drawing-250mm dia M 50.000 Included 0.00 0 0.00
196 Civil Works 100001404 995462 18% Supplying & laying hume pipe of grade (NP-3) excluding reinforcement and concrete as per drawing-100mm dia M 50.000 Included 0.00 0 0.00
197 Civil Works 100001409 995462 18% Supplying and erecting dewatering pumps-5 HP EA 4 Included 0.00 0 0.00
198 Civil Works 100007701 995462 18% Supplying and erecting dewatering pumps- 2 HP EA 4 Included 0.00 0 0.00
199 Civil Works 100001761 995462 18% Drains section A-A including culverts but excluding concrete & reinforcement steel M 1000.000 Included 0.00 0 0.00
200 Civil Works 100001762 995462 18% Drains Section B-B including culverts but excluding concrete & reinforcement steel M 1000.000 Included 0.00 0 0.00
201 Civil Works 100001763 995462 18% Drains Section C-C including culverts but excluding concrete & reinforcement steel M 600.000 Included 0.00 0 0.00
202 Civil Works 100001764 995462 18% Drains Section D-D including culverts but excluding concrete & reinforcement steel M 600.000 Included 0.00 0 0.00
203 Civil Works 100001682 995416 18% FFPH Building - Civil Works All civil works as per drawing and specifications complete, including - brickwork,finishing (externaland internal),windows etc.However, excavation, PCC,RCC and reinforcement shall be paid separately as per BPS M2 102.000 Included 0.00 0 0.00
204 Civil Works 100001700 995454 18% All civil works as per drawing and specification but excluding excavation, PCC, RCC, reinforcement but including finishing (internaland external) etc & all civil works complete in all respect - Water Tank for Fire Fighting Pump House EA 1 Included 0.00 0 0.00
205 Civil Works 100003477 995454 18% Rain water harvesting excluding reinforcement and concrete as per drawing EA 1 Included 0.00 0 0.00
206 Civil Works 100003437 995454 18% Switchyard Panel Room - Civil Works. All civil works as per drawing and specifications complete, including - brickwork, finishing(external and internal), windows etc. However, excavation, PCC, RCC and reinforcement shall be paid separately as per BPS. M2 203.000 Included 0.00 0 0.00
207 Civil Works 100001755 995424 18% Providing & Laying of SW pipes for external sewerage system as per technical specification 100mm dia pipe M 30.000 Included 0.00 0 0.00
208 Civil Works 100001756 995424 18% Providing & Laying of SW pipes for external sewerage system as per technical specification 150mm dia pipe M 20.000 Included 0.00 0 0.00
209 Civil Works 100001757 995424 18% Providing & Laying of SW pipes for external sewerage system as per technical specification 200mm dia pipe M 20.000 Included 0.00 0 0.00
210 Civil Works 100008638 995421 18% Supplying and laying CPVC pipe for external water supply system - 75 mm dia pipe M 30.000 Included 0.00 0 0.00
211 Civil Works 100008639 995421 18% Supplying and laying CPVC pipe for external water supply system - 50 mm dia pipe M 20.000 Included 0.00 0 0.00
212 Civil Works 100010100 995421 18% Supplying and laying CPVC pipe for external water supply system - 40 mm dia pipe M 20.000 Included 0.00 0 0.00
213 Civil Works 100010101 995421 18% Supplying and laying CPVC pipe for external water supply system - 25 mm dia pipe M 20.000 Included 0.00 0 0.00
214 Civil Works 100001683 995414 18% Control Room Building - Civil Works All civil works as per drawing and specifications complete, including - brickwork, finishing(external and internal), windows etc. However, excavation, PCC, RCC and reinforcement shall be paid separately as per BPS. M2 450.000 Included 0.00 0 0.00
215 Civil Works 100001740 995441 18% Septic tank and soakpit for CRB EA 1 Included 0.00 0 0.00
216 Civil Works 100001701 995411 18% Security Hut - Civil WorksAll civilworks as per drawing and specificationscomplete, including - brickwork,finishing (external and internal),windows etc.However, excavation, PCC,RCC and reinforcement shall be paidseparately as per BPS. M2 18.000 Included 0.00 0 0.00
217 Civil Works 100002488 995462 18% Septic tank and soakpit for Security Room EA 1 Included 0.00 0 0.00
218 Civil Works 100002911 995432 18% Earthwork in excavation & filling in all types of soil and soft/disintegrated rock in open areas/nallas/channels, to the requiredslopes, shapes, levels, elevations and profile, including trimming of bottom and slopes of excavation, bailing out rain(dewatering), pumping, removal of slush, preparing embankments/marginal banks, loosening, dressing, spreading material in layers notexceeding 200mm, as per direction of Engineer-in-Charge, water flooding, compacting to achieve 95% consolidation at optimum moisturecontent, finishing etc. all complete, for all leads and lifts within leveling boundary, including disposal of surplus earth andstacking of unsuitable material within a lead of 2.0 Km beyond substation boundary, with all labour, material, tools, tackles andequipment, safeguards and incidentals, Royalty,taxes etc. as necessary, as per drawings, specification and directions of theEngineer-in-Charge. Clearing of jungle is included in this item. (Only excavation/cutting will be measured for payment purpose.) M3 75000.000 Included 0.00 0 0.00
219 Civil Works 100002914 995432 18% Earthwork in excavation in Hard rocks in open areas/nallas/ channels, to the required slopes, shapes, levels, elevations andprofile, including trimming of bottom and slopes of excavation and stacking and disposal of rock for a lead up to 2.0 KM beyondleveling boundary and all lifts , with all labour, material, tools, tackles and equipment, safeguards and incidentals,Royalty,taxesetc. as per directions of the Engineer-in-Charge. Serviceable material if available shall be stacked at site as identified byEngineer-in-Charge.(50% void deduction from stack measurement) M3 10000.000 Included 0.00 0 0.00
220 Civil Works 100002913 995455 18% Providing and fixing main entrance gate as per drawings including Excavation, PCC, backfilling, RCC, reinforcement, MS steel,fabrication, painting etc complete LOT 1 Included 0.00 0 0.00
221 Civil Works 100002912 995454 18% Providing and fixing Pre cast RCC Boundary wall as per drawings and specifications, including centring, shuttering, moulding,RCC, reinforcement, casting, curing, hoisting, carriage of precast cols/panels to site,Excavation, PCC, backfilling,MS angles andConcertina coil etc. complete. M 1850.000 Included 0.00 0 0.00
222 Civil Works 100001433 995435 18% Soil Investigation: As per technical specification including all laboratory and field tests, report and recommendations. LOT 1 Included 0.00 0 0.00
223 Civil Works 100012380 995426 18% Design, Drawing and execution of Pre-fabricated structure labour Hut including toilet & baths with all materials, labours etccomplete in all respect as per the technical specification and direction of Engineer-in Charge. (Plinth area shall be measured forpayment purpose) M2 420.000 Included 0.00 0 0.00
224 Civil Works 170002803 995473 18% Providing and fixing 100mm UPVC pipes conforming to IS : 15328, for weep holes M 500.000 Included 0.00 0 0.00
225 Civil Works 170002158 995454 18% P&F filter media with coarse aggregate confined in chicken mesh . EA 100 Included 0.00 0 0.00
226 Civil Works 120001752 995428 18% 16.11 Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete. M2 4950.000 Included 0.00 0 0.00
227 Service : PMU & associated items-Pachora 170000502 998713 18% Service:- Phasor Measurement Unit (PMU) EA 2 Included 0.00 0 0.00
228 Service : PMU & associated items-Pachora 170000530 998734 18% WAMS TIME SYSTEM(GPS RECEIVER) EA 2 Included 0.00 0 0.00
229 Service : PMU & associated items-Pachora 170000503 998713 18% Installation of Substation Grade Layer-3 LAN Switches as per Technical Specification EA 3 Included 0.00 0 0.00
230 Service : PMU & associated items-Pachora 170000504 998713 18% Services:- Armored Fibre Optic Cable and associated termination equipment LOT 1 Included 0.00 0 0.00
231 Service : PMU & associated items-Pachora 170000501 998734 18% Integration of PMU with the PDC (Phasor Data Concentrator) of RLDCs and respective SLDCs as required. LOT 1 Included 0.00 0 0.00
400kV Bhopal (Sterlite) extension
232 420kV Equipment 100000328 998736 18% 336kV Surge Arrester (1-phase) EA 6 Included 0.00 0 0.00
233 420kV Equipment 100000340 998736 18% 420 kV Bus Post Insulator (Except for wave traps) EA 14 Included 0.00 0 0.00
234 420kV Equipment 100000275 998736 18% 420 kV, 4400 pF Capacitive Voltage Transformer (1-Phase) EA 6 Included 0.00 0 0.00
235 420kV Equipment 100000267 998736 18% 420kV, 3150A, 63kA Circuit Breaker(3-Phase) without closing resistor(with support structure) EA 4 Included 0.00 0 0.00
236 420kV Equipment 100000274 998736 18% 420 kV, 3000A, 63KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 12 Included 0.00 0 0.00
237 420kV Equipment 100000287 998736 18% 420kV, 3150A, 63KA, Isolator (3-phase)(Double Break) with one E/S EA 10 Included 0.00 0 0.00
238 PLCC Equipment 100000883 998734 18% 420 kV ,1 phase Bus Post Insulators for Line Traps EA 12 Included 0.00 0 0.00
239 PLCC Equipment 100002042 998734 18% 400kV,3150A,0.5mH ,63kA Line Trap EA 4 Included 0.00 0 0.00
240 400kV Control & Relay Panel 100000728 998736 18% 400kV Circuit Breaker Relay Panel with Auto Reclose (with Automation) EA 4 Included 0.00 0 0.00
241 400kV Control & Relay Panel 100000730 998736 18% 400kV Line Protection Panel (with Automation) EA 2 Included 0.00 0 0.00
242 400kV Control & Relay Panel 100000796 998736 18% Augmentation of existing 400kV bus bar protection scheme SET 1 Included 0.00 0 0.00
243 Substation Automation System 100002069 998736 18% Augmentation of Substation automation System for 400kV Main bay as per Technical Specification EA 2 Included 0.00 0 0.00
244 Substation Automation System 100002075 998736 18% Augmentation of Substation automation System for 400kV Tie bay as per Technical Specification EA 2 Included 0.00 0 0.00
245 Erection Hardware - 420kV 100000329 998731 18% Erection Hardware for 400kV I type layout-Line bay as per specification SET 2 Included 0.00 0 0.00
246 Erection Hardware - 420kV 100000338 998731 18% Erection Hardware for 400kV I type layout-Bus Work (For one diameter) as per specification SET 2 Included 0.00 0 0.00
247 Air Conditioning System 100001882 995463 18% Air conditioning system for Switchyard Panel Room of 6m length SET 1 Included 0.00 0 0.00
248 Fire Protection System 100002062 995461 18% Fire Detection and Alarm System for Switchyard Panel Room of 6 m length SET 1 Included 0.00 0 0.00
249 Fire Protection System 100006287 995461 18% Installation of 4.5 Kg CO2 type Portable Extinguisher . SET 2 Included 0.00 0 0.00
250 Illumination System 100001116 998739 18% Illumination System for switchyard panel room of 6 m length SET 1 Included 0.00 0 0.00
251 Illumination System 100001021 995461 18% Lighting Panel type ACP-2 as per technical specification EA 1 Included 0.00 0 0.00
252 Illumination System 100001024 998731 18% Sub Lighting panel (outdoor) type SLP (Switchyard and Street Lighting) EA 2 Included 0.00 0 0.00
253 Illumination System 100004930 998731 18% LED Flood Light Luminaries Type-FL-1 as per technical specification EA 10 Included 0.00 0 0.00
254 Illumination System 100004931 998731 18% LED Flood Light Luminaries Type FL-2 (250W) as per technical specification EA 10 Included 0.00 0 0.00
255 Illumination System 100004932 998731 18% LED Street Light Luminaire TYPE SL-L1 (= 45W)as per technical specification EA 10 Included 0.00 0 0.00
256 Illumination System 100004934 998731 18% Type L1 Street Lighting Pole of 6 meter as per technical specification. EA 10 Included 0.00 0 0.00
257 ACDB/DCDB 100000903 998736 18% 220V DCDB (Extn.) SET 1 Included 0.00 0 0.00
258 ACDB/DCDB 100007471 998736 18% 400V ACDB (Extn.) as per technical specification SET 1 Included 0.00 0 0.00
259 Cables 100008239 998736 18% 1.1KV GRADE POWER & CONTROL CABLE (PVC) 400 KV LINE BAY ALONGWITH CLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC SET 2 Included 0.00 0 0.00
260 Cables 100008198 998736 18% 1.1kV Grade Power & Control Cable (PVC) 400 kV Tie Bay alongwith clamps, lugs, glands, straight through joints etc SET 2 Included 0.00 0 0.00
261 Cables 100008270 998736 18% 1.1KV GRADE OTHER CABLES (NOT COVERED ABOVE) ALONGWITH CLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC LS 1 Included 0.00 0 0.00
262 Main Earthmat 100003103 998731 18% 40 mm MS rod for Main Earthmat KM 2.500 Included 0.00 0 0.00
263 400kV Gantry Structure 100001210 995455 18% Erection of Lattice Structures (MS Steel), to be designed during detailed engineering, for towers, beams and equipment supportstructure including pack plates / packwashers and gusset plates excluding fasteners and foundation bolts MT 87.000 Included 0.00 0 0.00
264 400kV Gantry Structure 100001680 995455 18% Erection of fasteners ( nuts, bolts and washers ) including step bolts for lattice and pipe structures to be designed duringdetailed engineering MT 4.000 Included 0.00 0 0.00
265 400kV Gantry Structure 100001681 995455 18% Erection of foundation bolts including nuts, checknut and washers for lattice and pipe structures to be designed during detailedengineering MT 1.000 Included 0.00 0 0.00
266 400kV Equipment Support Structure 100008220 995455 18% Equipment Structure including Foundation bolt-400kV CVT (1Ph) EA 6 Included 0.00 0 0.00
267 400kV Equipment Support Structure 100008222 995455 18% Equipment Structure including Foundation bolt-400kV class SA (1Ph) EA 6 Included 0.00 0 0.00
268 400kV Equipment Support Structure 100008223 995455 18% Equipment Structure including Foundation bolt-400kV BPI (1Ph) EA 14 Included 0.00 0 0.00
269 400kV Equipment Support Structure 100008224 995455 18% Equipment Structure including Foundation bolt-400kV Wave Trap (1Ph) EA 4 Included 0.00 0 0.00
270 400kV Equipment Support Structure 100008219 995455 18% Equipment Structure including Foundation bolt-400kV CT (1Ph) EA 12 Included 0.00 0 0.00
271 400kV Equipment Support Structure 100008221 995455 18% Equipment Structure including Foundation bolt-400kV Isolator (3Ph) EA 10 Included 0.00 0 0.00
272 Visual Monitoring System 100002500 998731 18% Color IP camera, with PAN, TILT and ZOOM facilities, alongwith all required Items, Accessories, Line Interface units, Fiber patchcords, Power supply units, Junction Boxes, Cables, Fiber Optic Cables, etc., and including Integration in existing Hardware andSoftware for Augmentation of Visual Monitoring System as per technical specification. SET 1 Included 0.00 0 0.00
273 Civil Works 100004518 995433 18% Excavation in all kind of soil including rock for all leads and lifts, backfilling, disposal of surplus earth within a lead up to2Km as per technical specification. The surplus earth shall be roughly graded . M3 4290.000 Included 0.00 0 0.00
274 Civil Works 100001325 995454 18% Providing and laying of Plain Cement Concrete (PCC) (1:4:8) M3 117.000 Included 0.00 0 0.00
275 Civil Works 100001326 995454 18% Providing and laying of Plain Cement Concrete (PCC) (1:2:4) M3 22.000 Included 0.00 0 0.00
276 Civil Works 100001327 995454 18% Providing and laying of Reinforced Cement Concrete M25 mix including pre cast, shuttering, Grouting of pockets & underpinning butexcluding steel reinforcement M3 644.000 Included 0.00 0 0.00
277 Civil Works 100001329 995454 18% Steel Reinforcement MT 41.000 Included 0.00 0 0.00
278 Civil Works 100001331 995455 18% Misc. Structural steel including rails, embedments, edge protection angles, gratings etc. but excluding the reinforcement steel andsteel for lattice and pipe structures. MT 12.000 Included 0.00 0 0.00
279 Civil Works 100001714 995428 18% Stone spreading in switchyard excluding PCC M2 2000.000 Included 0.00 0 0.00
280 Civil Works 100001713 995424 18% Antiweed treatment M2 4000.000 Included 0.00 0 0.00
281 Civil Works 100008110 995421 18% 3.75m wide Bitumen road with earthen shoulder including 100 mm dia RCC Hume Pipe @ 100 metre interval as per drawing and TS (as perDSR item no 16.35 and 16.30.1) and including 225 mm thick WBM in three equal layers of 75 mm each as per CPWD specification. M2 2250.000 Included 0.00 0 0.00
282 Civil Works 100001735 995462 18% RCC culverts and cable trench crossings including supplying and laying hume pipe 250mm dia of grade (NP-3) excluding concrete as perspecification. M 10.000 Included 0.00 0 0.00
283 Civil Works 100001736 995462 18% RCC culverts and cable trench crossings including supplying and laying hume pipe 300mm dia of grade (NP-3) excluding concrete as perspecification. M 10.000 Included 0.00 0 0.00
284 Civil Works 100003437 995454 18% Switchyard Panel Room - Civil Works. All civil works as per drawing and specifications complete, including - brickwork, finishing(external and internal), windows etc. However, excavation, PCC, RCC and reinforcement shall be paid separately as per BPS. M2 27.000 Included 0.00 0 0.00
285 Civil Works 100001433 995435 18% Soil Investigation: As per technical specification including all laboratory and field tests, report and recommendations. LOT 1 Included 0.00 0 0.00
286 Civil Works 100001542 995429 18% Dismantling & Re-erection of Existing fence M 20.000 Included 0.00 0 0.00
287 Civil Works 100001761 995462 18% Drains section A-A including culverts but excluding concrete & reinforcement steel M 600.000 Included 0.00 0 0.00
288 Civil Works 100001762 995462 18% Drains Section B-B including culverts but excluding concrete & reinforcement steel M 300.000 Included 0.00 0 0.00
289 Civil Works 100001763 995462 18% Drains Section C-C including culverts but excluding concrete & reinforcement steel M 150.000 Included 0.00 0 0.00
290 Civil Works 100001764 995462 18% Drains Section D-D including culverts but excluding concrete & reinforcement steel M 150.000 Included 0.00 0 0.00
291 Civil Works 100001712 995428 18% Removing,cleaning and washing of existing stones and respreading of stones in switchyard excluding PCC M2 2000.000 Included 0.00 0 0.00
292 Civil Works 100001328 995454 18% Providing and laying Plain Cement Concrete 1:5:10 (1 cement : 5 sand : 10 brick aggregate) M3 300.000 Included 0.00 0 0.00
293 Service : PMU & associated items-Bhopal 170000502 998713 18% Service:- Phasor Measurement Unit (PMU) EA 2 Included 0.00 0 0.00
294 Service : PMU & associated items-Bhopal 170000530 998734 18% WAMS TIME SYSTEM(GPS RECEIVER) EA 2 Included 0.00 0 0.00
295 Service : PMU & associated items-Bhopal 170000503 998713 18% Installation of Substation Grade Layer-3 LAN Switches as per Technical Specification EA 3 Included 0.00 0 0.00
296 Service : PMU & associated items-Bhopal 170000504 998713 18% Services:- Armored Fibre Optic Cable and associated termination equipment LOT 1 Included 0.00 0 0.00
297 Service : PMU & associated items-Bhopal 170000501 998734 18% Integration of PMU with the PDC (Phasor Data Concentrator) of RLDCs and respective SLDCs as required. LOT 1 Included 0.00 0 0.00
298 Communication Eqpt at Bhopal Service 100002812 998734 18% SDH Equipment (STM-16 MADM upto 5 MSP protected directions)-Base Equipment (Common cards, Cross Connect/control cards, optical basecards, power supply cards, power cabling, other hardware and accessories including sub racks, patch cord, DDF etc fully equipedexcluding optical interface & Tributary cards EA 1 Included 0.00 0 0.00
299 Communication Eqpt at Bhopal Service 170000433 998734 18% Optical Interface Cards/SFP# -S16.1 for SDH Equipment-STM-16 EA 4 Included 0.00 0 0.00
300 Communication Eqpt at Bhopal Service 170000437 998734 18% Optical Line Interface Card (to support minimum 200 Kms) for STM-16 EA 2 Included 0.00 0 0.00
301 Communication Eqpt at Bhopal Service 100002825 998734 18% Tributary interface- E1 interface (Minimum 16 nos.) SET 2 Included 0.00 0 0.00
302 Communication Eqpt at Bhopal Service 170000550 998336 18% Ethernet Interface 10/100 Base T with Layer-2 switching (Min 8 Interfaces per card) EA 2 Included 0.00 0 0.00
303 Communication Eqpt at Bhopal Service 100002829 998734 18% Tributary interface-Gigabit Ethernet Interfaces 10/100 Mbps with Layer -2 Switching (minimum 2 nos.) SET 1 Included 0.00 0 0.00
304 Communication Eqpt at Bhopal Service 170000375 998734 18% Equipment Cabinets-For SDH Equipments EA 1 Included 0.00 0 0.00
305 Communication Eqpt at Bhopal Service 170000551 998336 18% VOIP telephone instrument with one common switch (min. 8 port) EA 4 Included 0.00 0 0.00
306 Communication Eqpt at Bhopal Service 100002882 998336 18% Fibre Optic Approach cabling: Including installation hardware like ties/clips/cleats, conduits, ducts, supports, fittings,accessories etc.: 24 Fibre KM 1.000 Included 0.00 0 0.00
307 Communication Eqpt at Bhopal Service 170000356 998336 18% Fibre Optic Distribution Panel (FODP): Indoor Type: FC Coupling and mounted on ETSI 19" rack or slimline rack: Type 2 (96 Fibre) EA 1 Included 0.00 0 0.00
308 Communication Eqpt at Bhopal Service 170000427 998734 18% Optical Interface Cards/SFP# -S4.1 SDH Equipment -STM-4 EA 4 Included 0.00 0 0.00
Total Installation Charges 0.00 0 0
Total GST as confirmed by Bidder 0.00
Total Installation Charges 0.00
Total GST as confirmed by Bidder 0.00
* In case the bidder leaves the cell for confirmation of the SAC and/or GST rate “blank”, the SAC and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Place : Printed Name :
TBCB/400kV/Rajgarh/SS01/G1/R Schedule - 3
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES : ERECTION CHARGES) AS per Percent #REF!
As per lum-sum on Sch-3 0.00%
Bidder’s Name and Address (Sole Bidder) : To: As per Percent on Sch-3 #REF!
Contracts Services, 3rd Floor Total Discount #REF!
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
…….. …….. …….. …….. …….. …….. Sector-29, Multipackage lum-sum 0.00%
All Prices are in Indian Rupees. Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
SI. No. Description Unit Quantity Unit Erection Charges Total Erection Charges Unit Erection Charges Total Erection Charges Unit Erection Charges Total Erection Charges
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! (a) Detailed Soil Investigation
#REF! #REF! #REF! #REF! #REF! (b) All kinds of soil except fissured rock & hard rock
#REF! #REF! #REF! #REF! #REF! (e) River Crossing Location
#REF! #REF! #REF! #REF! #REF! (f)
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
Total Erection Price (A+B) #REF!
Place : Printed Name :
TBCB/400kV/Rajgarh/SS01/G1/R Schedule-4
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
(SCHEDULE OF RATES AND PRICES )
Bidder’s Name and Address (Sole Bidder) : To:
Contracts Services, 3rd Floor
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Training Charges for Training to be imparted
Date : -- Printed Name :
Place : Designation :
TBCB/400kV/Rajgarh/SS01/G1/R Schedule - 5
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
(SUMMARY OF TAXES & DUTIES APPLICABLE ON PLANT & EQUIPMENT)
Bidder’s Name and Address (Sole Bidder) : To:
Contracts Services, 3rd Floor
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Sl. No. Item Nos. Total Price (INR) After Discount After MPDiscount
1 TOTAL GST ON GOODS Excise Duty #REF! Excise Duty #REF!
Total GST for Supply of Goods (inter-alia including Type Test Charges) between the Contractor and the Employer (identified in Schedule 1') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable. 0.00
2 TOTAL GST ON SERVICES Sales Tax 0.00 Sales Tax 0.00
Total GST on Installation Services (Schedule-3) and Training to be imparted in India (Schedule-4), if aplicable 0.00 #REF! 0 #REF! 0
GRAND TOTAL [1+2] 0.00 Grand Total after Discount #REF! Grand Total after MPD #REF!
Date : -- Printed Name :
Place : Designation :
TBCB/400kV/Rajgarh/SS01/G1/R Schedule - 5
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
SUMMARY OF TAXES & DUTIES APPLICABLE ON GOODS
Bidder’s Name and Address (Sole Bidder) : To:
Contracts Services, 3rd Floor
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Sl. No. Item Nos. Total Price (INR)
1 TOTAL GST ON GOODS 0.00
Total GST for Supply of Goods (inter-alia including Type Test Charges) between the Contractor and the Employer (identified in Schedule 1') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable.
2 TOTAL GST ON SERVICES 0.00
Total GST on Installation Services (Schedule-3) and Training to be imparted in India (Schedule-4)
GRAND TOTAL [1+2] 0.00
Date : -- Printed Name :
Place : Designation :
TBCB/400kV/Rajgarh/SS01/G1/R Schedule - 6
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
(GRAND SUMMARY)
Bidder’s Name and Address (Sole Bidder) : To:
Contracts Services, 3rd Floor
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 1 0.00
Ex-works price of Plant and Equipment including Type Test Charges
2 TOTAL SCHEDULE NO. 2 0.00
Local Transportation, Insurance and other Incidental Services
3 TOTAL SCHEDULE NO. 3 0.00
Installation Charges
4 TOTAL SCHEDULE NO. 4 Not Applicable
Training Charges
5 TOTAL SCHEDULE NO. 5 0.00
Taxes and Duties
6 TOTAL SCHEDULE NO. 7 Not Applicable
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.]
GRAND TOTAL [1+2+3+4+5] 0.00
Date : -- Printed Name :
Place : Designation :
TBCB/400kV/Rajgarh/SS01/G1/R Schedule - 6 After Discount
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
(GRAND SUMMARY)
Bidder’s Name and Address (Sole Bidder) : To:
Contracts Services, 3rd Floor
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 1 0.00
Ex-works price of Plant and Equipment including Type Test Charges
2 TOTAL SCHEDULE NO. 2 0.00
Local Transportation, Insurance and other Incidental Services
3 TOTAL SCHEDULE NO. 3 0.00
Installation Charges
4 TOTAL SCHEDULE NO. 4 Not Applicable
Training Charges
5 TOTAL SCHEDULE NO. 5 0.00
Taxes and Duties
6 TOTAL SCHEDULE NO. 7 Not Applicable
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.]
GRAND TOTAL [1+2+3+4+5] 0.00
Date : -- Printed Name :
Place : Designation :
TBCB/400kV/Rajgarh/SS01/G1/R Schedule 7
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES ) AS per Percent #REF!
As per lum-sum on Sch-7 0.00%
Bidder’s Name and Address (Sole Bidder) : To: As per Percent on Sch-7 #REF!
Contracts Services, 3rd Floor Total Discount #REF!
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
…….. …….. …….. …….. …….. …….. Sector-29, Multipackage Discount 0.0000%
Type tests on Earthwire, Hardwar Fittings & accessories of conductor & earthwire:
Date : -- Printed Name :
Place : Designation :
Note : Bidder should indicate the name of test laboratories where type tests are proposed to be conducted
TBCB/400kV/Rajgarh/SS01/G1/R
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC 0 0 0
(SCHEDULE OF RATES AND PRICES ) 0 0 0
Bidder’s Name and Address (Sole Bidder) : 0
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
TBCB/400kV/Rajgarh/SS01/G1/R
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES : TYPE TEST CHARGES) AS per Percent #REF!
As per lum-sum on Sch-7 0.00%
Bidder’s Name and Address (Sole Bidder) : To: As per Percent on Sch-7 #REF!
Contracts Services, 3rd Floor Total Discount #REF!
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
…….. …….. …….. …….. …….. …….. Sector-29, Multipackage Discount 0.0000%
Type Tests on Earthwire
SL. NO. Description of Test Unit Quantity Unit Test Charge Total Test Charges (Rs.) Total Test Charges After Discount (Rs.) Dis Alert Total Test Charges After MPD (Rs.)
Sub-Total (I) 0.00
TOTAL TEST CHARGES (I) 0.00
Discount Sche-7 #REF! MPD Sche-7 #REF!
Dis Alert #REF!
Date : -- Printed Name :
Place : Designation :
Note : Bidder should indicate the name of test laboratories where type tests are proposed to be conducted
TBCB/400kV/Rajgarh/SS01/G1/R
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC 0 0 0
(SCHEDULE OF RATES AND PRICES : TYPE TEST CHARGES) 0 0 0
Bidder’s Name and Address (Sole Bidder) : 0
SL. NO. Description of Test 0
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
TBCB/400kV/Rajgarh/SS01/G1/R Schedule 7
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES ) AS per Percent #REF!
As per lum-sum on Sch-7 0.00%
Bidder’s Name and Address (Sole Bidder) : To: As per Percent on Sch-7 #REF!
Contracts Services, 3rd Floor Total Discount #REF!
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
…….. …….. …….. …….. …….. …….. Sector-29, Multipackage Discount 0.0000%
Type tests for Wangtoo Substation
SL. NO. HSN Code Whether HSN in column ‘2’ is confirmed. If not indicate applicable the HSN code * Rate of GST applicable ( in %) Whether rate of GST in column ‘4’ is confirmed. If not indicate applicable rate of GST * Description of Test Unit Quantity Unit Test Charge Total Test Charges (Rs.) 0 Total Test Charges After Discount (Rs.) Dis Alert Total Test Charges After MPD (Rs.)
TOTAL TYPE TEST CHARGES 0.00
Discount Sche-7 #REF! MPD Sche-7 #REF!
Dis Alert #REF!
Date : -- Printed Name :
Place : Designation :
Note : Bidder should indicate the name of test laboratories where type tests are proposed to be conducted
TBCB/400kV/Rajgarh/SS01/G1/R
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC 0 0 0
(SCHEDULE OF RATES AND PRICES ) 0 0 0
Bidder’s Name and Address (Sole Bidder) : 0
SL. NO. Description of Test 0
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
This letter of discount is optional. Bidder may / may not offer any discount.
TBCB/400kV/Rajgarh/SS01/G1/R Letter of Discount
LETTER OF DISCOUNT
Contract Services
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Sector-29, (near IFFCO Chowk)
Gurgaon (Haryana) - 122001
Subject : 400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
With reference to the subject tender, we hereby offer unconditional discount on the prices quoted by us as per details given here below : Eq Weightage of Rs/ % Final Discount Factor
1 Discount on lum-sum basis on total price quoted by us without Taxes & Duties. [The discount shall be proportionately applicable on all the items of all the Schdules i.e. Sch-1, Sch-2 & Sch-3] In Rs. 0.00 0.0000000000%
2 Discount on percent basis on total price quoted by us without Taxes & Duties. [The discount shall be proportionately applicable on all the items of all the Schdules i.e. Sch-1, Sch-2 & Sch-3] In Percent (%) 0.00 0.00%
3 Discount on lum-sum basis on the Schedules as given below : [The discount shall be proportionately applicable on all the relevent items of the respective Schdules.] In Rs.
Schedule-1 : Ex works prices In Rs. 0.00 0.0000000000% Schedule-1 : Ex-Works Price 0.0000000000%
Schedule-2 : Freight & Insurance In Rs. 0.00 0.0000000000% Schedule-2 : Freight & Insurance 0.0000000000%
Schedule-3 : Installation Charges In Rs. 0.00 0.0000000000% Schedule-3 : Erection Charges 0.0000000000%
Schedule-4 : Training Charges In Rs. 0.00 0.0000000000% Schedule-4 : Training Charges 0.0000000000%
Schedule-7 : Type Test Charges In Rs. Schedule-7 : Type Test Charges 0.0000000000%
4 Discount on percent basis on the Schedules as given below : [The discount shall be proportionately applicable on all the relevent items of the respective Schdules.] In Percent (%)
Schedule-1 : Ex works prices In Percent (%) 0.00 0.00%
Schedule-2 : Freight & Insurance In Percent (%) 0.00 0.00%
Schedule-3 : Installation Charges In Percent (%) 0.00 0.00%
Schedule-4 : Training Charges In Percent (%) 0.00 0.00%
Schedule-7 : Type Test Charges In Percent (%) 0.00%
Discount(s) offered at sl. No. 1 to 4 will get displayed and accounted for automatically in the respective items of the Schedules.
5 We hereby offer Multi-package discount as given below:
Multi-Package Discount(s) offered at sl. No. 5 will not get automatically accounted for in the respective items of the Schedules. The same shall be worked out saparately for evaluation.
Please consider this letter of discount as the integral part of our price bid.
Thanking you, we remain,
Yours faithfully,
For and on behalf of …….. …….. …….. …….. …….. ……..
Date : -- Printed Name :
Place : Designation :
Details of Octroi
Sl No. Description of Items Amount on which Octroi is applicable Rate of Octroi Octroi
Details of Entry Tax
Sl No. Description of Items Amount on which Entry Tax is applicable Rate of Entry Tax Entry Tax
Details of Other Taxes & Duties
Sl No. Description of Items Amount on which Other Taxes & Duties are applicable Description of Taxes & Duties Rate of Taxes & Duties Amount of Taxes & Duties
TBCB/400kV/Rajgarh/SS01/G1/R Bid Form 2nd Envelope Sole Bidder 1 st 1 January
0 2 nd 2 February
BID FORM (Second Envelope) 3 rd 3 March
Bid Proposal Ref. No. 5 th 5 May
Date : -- 6 th #VALUE! 6 June
7 th #VALUE! 7 July
To: 8 th #VALUE! 8 August
Contracts Services, 3rd Floor 9 th #VALUE! 9 September
Power Grid Corporation of India Ltd., 10 th 10 October
"Saudamini", Plot No.-2 11 th 11 November
Sector-29, 12 th 12 December
Gurgaon (Haryana) - 122001 13 th
Name of Contract : 400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC 15 th
Dear Ladies and/or Gentlemen, 16 th
Schedule 1 Plant and Equipment (Including Mandatory Spare Parts) to be supplied, including Type Test Charges. 21 st
Schedule 2 Local Transportation, In-transit Insurance, loading and unloading 22 th
Schedule 3 Installation Charges. Sole Bidder 23 th
Schedule 4 Training charges for training to be imparted. 24 th
Schedule 5 Taxes and Duties not included in Schedule 1 25 th
Schedule 6 Grand Summary [Schedule 1to 5] 26 th
2.5 We declare that items left blank in the Schedules will be deemed to have been included in other items. The TOTAL for each Schedule and the TOTAL of Grand Summary shall be deemed to be the total price for executing the Facilities and sections thereof in complete accordance with the Contract, whether or not each individual item has been priced. 31 st
3.0 We confirm that except as otherwise specifically provided our Bid Prices in this Second Envelope include all taxes, duties, levies and charges as may be assessed on us/our Associate (applicable for Foreign Bidder), our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
3.1 100% of applicable Taxes and Duties i.e GST which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents.
3.3 We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN, in all the states where the project is located and the states from which we shall make our supply of goods.
4.0 # (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions.
5.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of …….. …….. …….. …….. …….. ……..
Date : -- Printed Name :
Place : Designation :
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2 : Power of Attorney. Bidders may use their own proforma for furnishing the required information with the bid.
STATEMENT OF QUOTED / CORRECTED PRICES
All Figures are in Rupees
Sl. No. Price Component Quoted Price Corrected Price
1 TOTAL SCHEDULE NO. 1:Ex-Works Price of Plant and Equipment including Type Test Charges 0.00 0.00
2 TOTAL SCHEDULE NO.2: Local Transportation, Insurance and other Incidental Services. 0.00 0.00
3 TOTAL SCHEDULE NO.3: Installation Charges 0.00 0.00
4 TOTAL SCHEDULE NO.4: Training Charges Not Applicable Not Applicable
5 TOTAL BID PRICE: (Excluding Taxes & Duties) 0.00 0.00
6 DISCOUNT #REF! #REF! #REF!
7 NET BID PRICE (Excluding Taxes & Duties) #REF! #REF!
8 TAXES & DUTIES PAYABLE ADDITIONALLY
A) EXCISE DUTY 0 0.00
B) CENTRAL SALES TAX 0 0.00
C) VAT #REF! 0.00
D) ENTRY TAX / OCTROI #REF! 0.00
F) TOTAL TAXES & DUTIES #REF! 0.00
8 TOTAL BID PRICE (INCLUDING TAXES & DUTIES) #REF! 0.00
9 TOTAL SCHEDULE NO.7: Type Test Charges [Total of this Schedule is included in Schedule-1 above] 0.00 0.00
I) Bidder has indicated the following taxes and duties additionally applicable for their bid:
Excise Duty % as Excise Duty
#REF! VAT #REF! #REF!
#REF! Entry Tax/ Octroi #REF! #REF!
Others as Others
II) With regard to Entry Tax, it may be mentioned that the substations covered under the subject pacakge falls in State of MP, where an entry tax @ 2% of Purchase Price is applicable. In view of the above, the taxes and duties inter-alia including entry tax applicable for the bids are calculated :
a) Ex-Works Price of Direct Supplies (after discount, if any) Rs. 0
b) Excise Duty, as applicable on (a) above at the rate : 10.00% Rs. 0
c) Amount on which Sales Tax is applicable 0.00 0
d) CST, as applicable on (a) + ED (b) above at the rate : 2.00% Rs. 0
e) VAT, as applicable on (a) + ED (b) above at the rate : 1.00% 0
g) Purchase Price for Entry Tax (Total Ex-Works+F&I+ED+CST+Others) Rs. 0
h) Entry Tax, as applicable on (e) above at the rate : Rs. 0.00
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC Statement of Quoted / Corrected Prices Page
Spec. No. TBCB/400kV/Rajgarh/SS01/G1/R
STATEMENT OF QUOTED / CORRECTED PRICES
All Figures are in Rupees
Sl. No. Price Component Quoted Price Corrected Price
1 TOTAL SCHEDULE NO. 1:Ex-Works Price of Plant and Equipment including Type Test Charges 0.00 0.00
2 TOTAL SCHEDULE NO.2: Local Transportation, Insurance and other Incidental Services. 0.00 0.00
3 TOTAL SCHEDULE NO.3: Installation Charges 0.00 0.00
4 TOTAL SCHEDULE NO.4: Training Charges Not Applicable Not Applicable
5 TOTAL BID PRICE: (Excluding Taxes & Duties) 0.00 0.00
6 DISCOUNT #REF! #REF!
7 NET BID PRICE (Excluding Taxes & Duties) #REF! #REF!
8 TAXES & DUTIES PAYABLE ADDITIONALLY
A) EXCISE DUTY #REF! 0.00
B) CENTRAL SALES TAX /VAT #REF! #REF!
C) ENTRY TAX / OCTROI #REF! #REF!
D) OTHERS #REF! 0.00
E) TOTAL TAXES & DUTIES #REF! #REF!
8 TOTAL BID PRICE (INCLUDING TAXES & DUTIES) #REF! #REF!
9 TOTAL SCHEDULE NO.7: Type Test Charges [Total of this Schedule is included in Schedule-1 above] Not Applicable Not Applicable
I) Bidder has indicated the following taxes and duties additionally applicable for their bid:
a) Excise Duty Rs. #REF!
b) CST /VAT Rs. #REF!
c) Entry Tax / Octroi Rs. #REF!
d) Others Rs. #REF!
II) Bidder has offered following discount(s)
III) With regard to Entry Tax, it may be mentioned that the substations covered under the subject pacakge falls in State of MP, where an entry tax @ 1% of Purchase Price is applicable. In view of the above, the taxes and duties inter-alia including entry tax applicable for the bids are calculated : Details of dicounts
a) Ex-Works Price of Direct Supplies (after discount, if any) Rs. 0 Gross LS #REF! #REF! #REF! Gross % #REF! #REF! #REF!
b) Excise Duty @ 10.3% of (a) above Rs. 0 #REF! #REF!
c) CST / VAT @ 2% of Ex-Works of Direct Supplies (a) + ED (b) above Rs. #REF! Sch-1 Direct LS #REF! #REF! #REF! Sch-1 Direct % #REF! #REF! #REF!
d) Others Rs. Sch-1 BO LS #REF! #REF! #REF! Sch-1 BO % #REF! #REF! #REF!
e) Purchase Price for Entry Tax (Total Ex-Works+F&I+ED+CST+Others) Rs. #REF! Sch-2 LS #REF! #REF! #REF! Sch-2 % #REF! #REF! #REF!
f) Entry Tax @ 1% of (e) above Rs. #REF! Sch-3 LS #REF! #REF! #REF! Sch-3 % #REF! #REF! #REF!
Sch-7 LS #REF! #REF! #REF! Sch-7 % #REF! #REF! #REF!
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC Statement of Quoted / Corrected Prices Page Different Manner #REF!
Text for Discount #REF!
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
Name of Package 400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
Package No : SS01
Specification No. : TBCB/400kV/ Rajgarh /SS01/G1/R
Completion Period 15 Months
: Substation Package -SS01 : General guidelines for filling up the Attachments : Substation Package -SS01 :
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
Specification No.: TBCB/400kV/ Rajgarh /SS01/G1/R
1 Fill up only green shaded cells in the relevent attachments.
2 Attachments 3(JV), 3(QR), QR, 4, 4(A), 4(B), 5, 5(A), 6, 7, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 25, 26, 27, 28 and Bid Form for 1st Envelope are included here.
3 Attachment 1 Bid Security : Not Applicable
4 Attachment 2 Power of Attorney : No specific format is provided by POWERGRID. Bidder may use their own format.
5 Attachment 8 Manufacturer’s Authorisation Form : To be furnished as per proforma provided in the bidding document, on the letter head of the each Manufacture proposed to supply main items.
6 Attachment 14 Integrity Pact : To be submitted as per ITB Clause No. 9.3(o) and as per remarks in the Attach 14-IP.
7 Attachment 20 KMP Declaration : Format enclosed in Volume-III of the Bidding Documents.
8 Attachment 21 Authorization certificate issued by Domestic Manufacturer for selling Domestically Manufactured Iron & Steel Products : Format enclosed in Volume-III of the Bidding Documents.
9 Attachment 22: Affidavit of Self certification regarding Domestic Value Addition in Iron & Steel Products : Format enclosed in Volume-III of the Bidding Documents.
10 Attachment 23 Affidavit: Format enclosed in Volume-III of the Bidding Documents.
11 Attachment 24: Declaration regarding noConfirmation regarding furnishing Declaration regarding Non-Participation as a Bidding Company or as a member of any Bidding Consortium in Transmission Project under Tariff Based Competitive Bidding Route.: as per Form No. 27, Section-VI of Vol.-I of the bidding documents
12 Attachment 25: Declaration by the Bidder regarding events encountered pursuant to ITB Clause 2.1
13 Attachment 26 Affidavit of Self certification regarding Minimum Local Content in line with PPP-MII order, if applicable
14 Attachment 27: Certificate from statutory auditor or cost auditor of the company (in the case of companies) or from a practicing cost accountant or practicing chartered accountant (in respect of suppliers other than companies) giving the percentage of Local Content, in line with PPP-MII order, if applicable
15 Attachment 28: Certification by the Bidder per DoE Order in line with ITB Clause 2.1
16 Attachment 29: Bid Securing Declaration to be submitted by the Bidder.
17 Attachment 30: Undertaking regarding submission of original/Hard copy part of the bid
Note : Enable the Active X Control & Macros. Also ensure to keep option of "Trust acess to VBA project object Model" cheched [√]. Ensure that you work on MS Excel 2007 or higher version.
पावर ग्रिड कारपोरेशन ऑफ इण्डिया लिमिटेड
(भारत सरकार का उद्यम)
Power Grid Corporation of India Limited
(A Government of India Enterprises)
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
Specification No. :TBCB/400kV/ Rajgarh /SS01/G1/R Sole Bidder 1
JV (Joint Venture) 2 or More
Enter following details of the bidder
Specify type of Bidder [Select from drop down menu] Sole Bidder 0
Name of Sole Bidder
Address of Sole Bidder
Name of other Partner - 2 (More, if any)
Address of other Partner - 2 (More, if any)
Any Tower Parts Manufacturer proposed other than the bidder [Yes / No] No
Proposed Tower Parts Manufacturer other than the bidder, if any [Maximum two nos.]
Specification No. :TBCB/400kV/ Rajgarh /SS01/G1/R Attachment-3(JV) SS01 Sole Bidder SS01
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
(Joint Venture Agreement and Power of Attorney for Joint Venture*)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
This Attachment is Not Applicable
Name(s) and Addresse(s) of other partner(s)
The Joint Venture Agreement (as per the proforma attached at no. 15 in Section-VI, Sample Forms and Procedures, Conditions of Contract, Vol.-I of the Bidding Documents) and Power of Attorney for Joint Venture (as per the proforma attached at no. 14 in Section-VI, Sample Forms and Procedures, Conditions of Contract, Vol.-I of the Bidding Documents) are enclosed herewith.
Date : Printed Name : 0
Place : Designation : 15
Specification No. :TBCB/400kV/ Rajgarh /SS01/G1/R Attachment-3(QR) SS01
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
(Qualifying Requirement Data)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
For our Qualifying Requirements Data, please refer Attachment-QR of this volume.
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/400kV/ Rajgarh /SS01/G1/R Attachment-QR SS01
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
(Qualifying Requirement Data)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name: Power Grid Corporation of India Ltd.,
Address: "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
In support of the Qualification Requirements (QR) for bidders, stipulated in Annexure-A (BDS) of the Section - III (BDS), Volume-I & additional information required as per ITB clause 9.3(c) of the Bidding Documents, we furnish herewith our QR data/details/documents etc., alongwith other information, as follows (The QR stipulations have been reproduced in italics for ready reference, however, in case of any discrepancy the QR as given in BDS shall prevail).
We have submitted bid as individual firm. Sole Bidder
[For details regarding Qualification Requirements of a Joint Venture, please refer para 4.0 below.]
We are furnishing the following details/document in support of Qualifying requirement for the subject package.
A upload scanned copies of original documents of Sole Bidder/ all Partner of the JV (if applicable) along with the bid on the portal.
a) The constitution or legal status;
b) The principal place of business;
c) The place of incorporation (for bidders who are corporations); or the place of registration and the nationality of the Owners (for applicants who are partnerships or individually-owned firms).
d) Whether bidder anticipate any change in legal structure/ ownership of their organisation at present
If Yes, please enclose details of same and copy of procedural document(s) with reference to the same/ as required statutorily, as of now
a) Bidders submitting their Bids in Joint Venture may note that they have to furnish the JV Agreement and Power of Attorney of JV in line with the provisions of Bidding Document alongwith Bid Security and Integrity Pact in physical form before deadline for submission of hard copy of documents.
b) Attach written Power of Attorney of the Signatory of the Bid (For sole bidder / Lead Partner of the JV) and signatories of other partners of the JV (Signing the JV Agreement / Attorney of the JV)
1.0 GENERAL INFORMATION
Bidder is required to provide general information as per the following format.
[Where the Bidder proposes to use named subcontractor(s) for critical components of the works or for work contents in excess of ten (10) percent of the bid price, the following information should also be supplied for the subcontractor(s)].
S No. Particulars For individual firm
1 Name of the Firm
2 Head Office/ Registered Office Address
5 Contact Person
6 Place of Incorporation/ Registration
7 Year of Incorporation/ Registration
8 Nationality of
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\Case_Studies.pdf F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\new.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\Case_Studies.pdf F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\new.pdf
KRA.pdf Case_Studies.pdf new.pdf
2.0 TECHNICAL REQUIREMENTS
2.1 Technical Experience
2.1.1 {Reference para 1.1 of Annexure-A (BDS)}
The bidder’s experience should include the following:
i) The Bidder should have carried out the following as a prime contractor+: (a) Successfully completed$ physical construction of one (1) transmission line project of not less than 100kms of 345kV D/C or higher voltage class transmission line within the last seven (07) years as on the originally scheduled last date of bid submission (i.e 17.06.2021) involving the following scope of work: i) Tower foundation, erection and stringing ii) Supply of tower & tower parts iii) Supply of line material viz. Conductor or Insulator or Hardware Fittings And (b) Designed and successfully tested/got successfully tested@ 345kV D/C or higher voltage class transmission line tower
Note + : In case of works executed under a contract that had been awarded on a Joint Venture, the experience of individual Joint Venture partner shall be considered limited to the scope of that partner under the said contract. $ Successfully completed means issue of provisional or final taking over certificate (TOC) by the Employer to the contractor for the referred contract. @Designed and Successfully tested /got successfully tested means validation of design through testing and issue of test certificate thereof by the Test Agency to the contractor
In case Bidder is a holding company, the technical experience referred to in clause 2.1.1 above shall be of that holding company only (i.e. excluding its subsidiary/group companies). In case Bidder is a subsidiary of a holding company, the technical experience referred to in clause 2.1.1 above shall be of that subsidiary company only (i.e. excluding its holding companies).
[For Joint Venture bidders, the requirement to be met is stipulated under para 1.5 of Annexure-A (BDS)]
2.1.2 Using the following format, each Bidder (individual firms or partners of a joint venture) is requested to list the contracts of a nature similar to the proposed contract for which the Bidder wishes to qualify, undertaken during the last seven (07) years. The information is to be summarised for each such contract separately. (In case of Joint Venture bidder, the information/details pertaining to each partners of the joint venture are to be furnished).
(The bidder shall attach documentary evidence, such as copies of utility certificates etc., in support of its general experience as listed in the following proforma for each experience/ Contract with the help of "Attach" Buttons provided in table given herebelow in PDF format)
Format-A for individual firm or for different Partner of a Joint Venture (JV):
Bidder’s Name :
Single Firm/Lead Partner/Other Partners of a JV : Single Firm Single Firm
a Name of Contract Undertaken
b Contract Reference No. & Date of Award
c Name and Address of the Employer/Utility for whom the Contract was executed by the firm
d Scope of work executed under the above contract (Tick only whichever is/are applicable)
e Details/features of the Contract undertaken relevant to the stipulated QR (as in Sl No (i) of 2.1.1)
i) Route Length of Transmission Line (In kms.) (In kms.)
ii) Tower locations (In Nos.) (In Nos.)
iii) Voltage level of Transmission Line (In kV) (In kV)
iv) No. of conductor per phase (no.) (no.)
iv) Whether Transmission line strung with Tension Stringing Equipments (Yes/No) (Yes/No)
v) if yes km. of line strung with Tension Stringing Equipments (km.) (km.)
f Details/features of the Contract undertaken relevant to the stipulated QR (as in Sl No (i) of 2.1.2)
i) River Crossing Span (In Meters.) (In Meters.)
ii) Tower Height (In Meters.) (In Meters.)
iii) Voltage level of Transmission Line (In kV) (In kV)
iv) Whether Transmission line strung with Tension Stringing Equipments (Yes/No) (Yes/No)
f Capacity in which the Contract was undertaken (Select One from Drop Down)
If Contract was taken as JV partner scope of partner
h Date of Completion of Contract
g Details of documents furnished in the Bid, in support of the aforesaid data/ details/ information
KRA.pdf KRA.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf
Format-B for individual firm or for different Partner of a Joint Venture (JV):
Name of the Contractor
h Voltage level of the Tower Designed (mention the voltage of the Tower)
Whether the Designed tower tested (mention Yes/No) If, yes, please enclose the test certificate issued by the Test Agency
Bidder’s Name : 0 0
Single Firm/Lead Partner/Other Partners of a JV : Single Firm Single Firm
a Name of Contract Undertaken
b Contract Reference No. & Date of Award
c Name and Address of the Employer/Utility for whom the Contract was executed by the firm/Partner of a JV
d Scope of work executed under the above contract (Tick only whichever is/are applicable)
e Details/features of the Contract undertaken relevant to the stipulated QR (as in Sl No (i) & (ii) of 2.1.1)
i) Route Length of Transmission Line (In kms.) (In kms.)
ii) Tower locations (In Nos.) (In Nos.)
iii) Voltage level of Transmission Line (In kV) (In kV)
iv) No. of conductor per phase (no.) (no.)
v) Whether Transmission line strung with Tension Stringing Equipments (Yes/No) (Yes/No)
v) if yes km. of line strung with Tension Stringing Equipments (km.) (km.)
f Details/features of the Contract undertaken relevant to the stipulated QR (as in Sl No (i) of 2.1.2)
i) River Crossing Span (In Meters.) (In Meters.)
ii) Tower Height (In Meters.) (In Meters.)
iii) Voltage level of Transmission Line (In kV) (In kV)
iv) Whether Transmission line strung with Tension Stringing Equipments (Yes/No) (Yes/No)
f Capacity in which the Contract was undertaken (Select One from Drop Down)
If Contract was taken as JV partner, scope of partner
g Date of Completion of Contract
h Details of documents furnished in the Bid, in support of the aforesaid data/details/information
Case_Studies.pdf KRA.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\Case_Studies.pdf F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\Case_Studies.pdf F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf
2.2 Equipment Capabilities
2.2.1 {Reference para 1.2 of Annexure-A (BDS)}
a) The bidder should own or have access to the following key erection equipment: Minimum 6 no. of 15 Tonnes Capacity or #Minimum 3 no. of 24 Tonnes Capacity for Package TL01
2.2.2 The bidder is required to furnish data/details/information relevant to the stipulated QR as follows:
i) Capacity of Erection Equipment (in tonnes)
ii) (a) Whether Erection Equipments are Owned or leased
ii) (b) No. of Erection Equipments (Indicate separately no. of Erection Equipments) 15 Tonnes --->
ii) (c) Details of each of the TSEs stated at (i) above are to be furnished in the following table: {Use separate sheet, if required, and upload scanned copy}
Name of the Manufacturer
Current Location
Commitment Detail
ii) (d) If leased, whether Consent letter submitted alongwith the Bid?
Format-B for individual firm or for different Partner of a Joint Venture (JV):
Name of the Contractor
Voltage level of the Tower Designed (mention the voltage of the Tower)
Whether the Designed tower tested (mention Yes/No) If, yes, please enclose the test certificate issued by the Test Agency
2.0 Financial Position
2.1 {Reference para 1.1 of Annexure-A (BDS)}
(a) Minimum Average Annual Turnover*(MAAT) for best three years i.e. 36 months out of last five financial years of the bidder should be Indian Rs. 166.80 crore *Note- Annual Gross Revenue from operations/Gross operating income as incorporated in the profit & loss account excluding other operative income/ other income (b) Bidder shall have liquid assets (L.A) or/ and evidence of access to or availability of credit facilities of not less than Indian Rs. 27.80 crore
In case bidder is a holding company, the financial position criteria referred to in clause 2.1 above shall be of that holding company only (i.e excluding its subsidiary/ group companies). In case bidder is a subsidiary of a holding company the financial position criteria referred to in clause 2.1 above shall be of that subsidiary company only ( i.e excluding its holding company)
Note: Relaxation for STARTUPs ^/ MSEs Start-Ups^/ MSEs, meeting the specified requirements at Para 3.1 (a) in Financial Position shall also be considered qualified if they meet Eighty(80) % of the requirement specified at Para 3.1.(b) & 3.1 (c) in Financial Position. ^Start-Ups as defined by DIPP, applicable as on the originally scheduled date of bid opening.
[Further, for joint venture bidders, the requirement to be met is stipulated under para 1.5 of Annexure-A of BDS.]
3.2 In support of its ‘Financial Position’, in line with the above, the Bidder (Individual firm or all the JV partners in case of JV bidder) must provide the relevant information, alongwith documentary evidence, in the following format A:
A Whether the bidder is a MSE (Yes/No) If Yes, please enclose supporting documents/documentary evidence
B Whether the bidder is a Start-Up as defined by DIPP (Yes/No) If Yes, please enclose supporting documents/documentary evidence
For individual firm
For Lead Partner For Partner – 1 For Partner - 2
Name of the Bidder
A Average Annual Turnover details: Average annual turnover in Rs. Million Average annual turnover in Rs. Million Average annual turnover in Rs. Million
Sl No Financial year
Do you have audited results for FY 2014-15 Yes
Average Annual Turnover for best Three Years is
For individual firm
For Lead Partner For Partner – 1 For Partner - 2
Name of the Bidder
C Net Worth (Paid Up Capital+Free Reserves and Surplus+Misc expenses to the extent not written off): Net Worth (in Rs. Millions) Net Worth (in Rs. Millions) Net Worth (in Rs. Millions)
Sl No Financial year
Do you have audited results for FY 2019-20 Yes
Average Annual Turnover for best Three Years is
For individual firm
For Lead Partner For Partner – 1 For Partner - 2
Name of the Bidder
C Cash Flow from operations(Net Cash from Operating Activity+Dividend and Dividend Tax+Repayment of debt): Cash Flow (in Rs. Millions) Cash Flow (in Rs. Millions) Cash Flow (in Rs. Millions)
Sl No Financial year
Do you have audited results for FY 2012-13 Yes
For individual firm
For Lead Partner For Partner – 1 For Partner - 2
Name of the Bidder
D Net Profit after Tax: Net Profit (in Rs. Millions) Net Profit (in Rs. Millions) Net Profit (in Rs. Millions)
Sl No Financial year
Do you have audited results for FY 2012-13 Yes
E Liquid Assets
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
4.0 Joint Venture (JV) Firms
4.1 (a) In case a bid is submitted by a Joint Venture(JV) of two or more firms as partners, joint venture must comply with the following minimum criteria:
i) All the partners of the JV shall meet individually the financial position criteria given at Para 3.1 (a) above.
ii) The lead partner of Joint Venture shall meet not less than 50 % of the Technical Experience criteria given at Para 2.1.1(i) above and not less than 40% of the Financial Position criteria given at Para 3.1 (b) & (c) above.
iii) Each of the other partner(s) shall meet individually not less than 25% of the Technical Experience criteria given at Para 2.1.1(i) above or not less than 50% of Manufacturing facilities criteria given in para 2.2 above and not less than 25 % of the Financial position criteria given at Para 3.1 (b) & (c) above.
(b) In case the JV intend to participate in the package proposing supply of tower parts from a manufacturer(s) then the manufacturer(s) shall meet the Manufacturing Facilities criteria given at para 2.2.1 above.
(c) The joint venture must collectively meet the criteria of para 2.1.1, 2.2.1 and 3.1 above for which purpose the relevant figure of Technical Experience, Manufacturing Facilities, Equipment Capabilities and Financial Position (Para 3.1 (b) & (c) for each of the partners of the JV shall be added together.
(d) In case of Joint Venture, the following conditions shall also apply:
i) the bid, and in case of successful bid, the specified Form of Agreement shall be signed so as to be legally binding on all partners. (Form enclosed at Section-VI, Volume-I of Bidding Document)
ii) one of the partners shall be nominated as Lead Partner, and the Lead Partner shall be authorized to incur liabilities and receive instructions for and on behalf of any and all partners of the Joint Venture, and the entire execution of the Contract shall be done with the Lead Partner and payment under the contract shall be received by the Lead Partner on behalf of the Joint Venture as per power conferred to him in the Power of Attorney. The authorization shall be evidenced by submitting a Power of Attorney signed by legally authorized signatory of all the partners as per Performa in Section-VI of the Conditions of contract, Vol-I of the bidding document. The payment under the Contract can also be received by other partner(s) based on authorization of Lead Partner.
iii) all partners of the Joint Venture shall be liable jointly and severally for the execution of the Contract in accordance with the Contract terms, and a statement to this effect shall be included in the authorization mentioned under (ii) above as well as in the Bid Form and in the Contract Form (in case of a successful bid). Doc Name KRA.pdf
iv) Agreement entered into by the Joint Venture partners shall be submitted with the bid. F:\KRA.pdf
4.2 In accordance with the above, in case of JV bidders, it should be ensured that necessary details including those pertaining to each JV partner are furnished and the scanned copies of the corresponding documents are uploaded on the portal . Further, the JV bidders should also ensure that other requirements are complied with. The lists of documents attached are to be indicated below:
3.0 The Bidder shall also furnish following documents/details with its bid. {Reference ITB clause 9.3 (c)}
3.1 The complete annual reports together with Audited statement of accounts of the company for last five years of its own (separate) immediately preceding the date of submission of bid.The Bidder shall also furnish documentary evidence/ declaration regarding Financial re-structuring of the company, if any
Note I. In the event the bidder is not able to furnish the information of its own (i.e separate), being a subsidiary company and its accounts are being consolidated with its group/holding/parent company, the bidder should submit the audited balance sheets, income statements, other information pertaining to it only (not of its group/Holding/Parent Company) duly certified by any one of the authority [ (i) Statutory Auditor of the bidder /(ii) Company Secretary of the bidder or (iii) A certified Public Accountant] certifying that such information/documents are based on the audited accounts as the case may be.
II. Similarly, if the bidder happens to be a Group/Holding/Parent Company, the bidder should submit the above documents/information of its own (i.e. exclusive of its subsidiaries) duly certified by any one of the authority mentioned in Note-I above certifying that these information/documents are based on the audited accounts, as the case may be.
3.2 The Bidder should accordingly also provide the following information/documents (In case of JV bidders, information should be provided separately for all the Partners of JV in the given format): F:\Orissa C\Rev\Case_Studies.pdf F:\Orissa C\Rev\KRA.pdf F:\Orissa C\Rev\office order.pdf
F:\Orissa C\Rev\Case_Studies.pdf F:\Orissa C\Rev\KRA.pdf F:\Orissa C\Rev\office order.pdf
Audited balance sheet and income statements for the last five years as per the following: Case_Studies.pdf KRA.pdf office order.pdf
For individual firm F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\new.pdf F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\Case_Studies.pdf
For Lead Partner For Partner – 1 For Partner - 2 F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\new.pdf F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\Case_Studies.pdf
A Years preceding to the bid opening Audited Balance Sheet and Income Statements enclosed Audited Balance Sheet and Income Statements enclosed Audited Balance Sheet and Income Statements enclosed KRA.pdf new.pdf Case_Studies.pdf
1st Year F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\Case_Studies.pdf F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\new.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\Case_Studies.pdf F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf F:\Orissa C\Rev\Case_Studies.pdf
Case_Studies.pdf KRA.pdf new.pdf
2nd Year F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\Case_Studies.pdf F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\new.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\Case_Studies.pdf F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\new.pdf
Case_Studies.pdf KRA.pdf new.pdf
3rd Year F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\Case_Studies.pdf F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\new.pdf
D:\My Documents\Office work\Current\Chattisgarh\TW01 & TW02\02-Re-retender\Documents\TW01\Vol-III\Case_Studies.pdf F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\new.pdf
Case_Studies.pdf KRA.pdf new.pdf
B Whether bidder organisation is underway of Financial re-structuring
If Yes, please enclose the details of same and data/ documents establishing the same
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/400kV/ Rajgarh /SS01/G1/R Attachment-4 SS01
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
(Form of Certificate of Origin and Eligibility)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We hereby certify that equipment and materials to be supplied are produced in [Enter the name of country where from equipments & material shall be supplied] eligible source country. Equipments & Materials produced in [Name of countries] Company incorporated & registered in [Name of countries]
We hereby certify that our company is incorporated and registered in [Enter the name of country where from equipments & material shall be supplied] eligible source country.
Date : Printed Name :
Place : Designation :
country. country. [Enter the name of country where from equipments & material shall be supplied] [Enter the name of country where from equipments & material shall be supplied]
Specification No. :TBCB/400kV/ Rajgarh /SS01/G1/R Attachment-4(A) SS01
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
(List of Special Maintenance Tools & Tackles)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We are furnishing below the list of special maintenance tools & tackles for various equipment under the subject package. The prices for these tools & tackles are included in our lumpsum bid price. We further confirm that the list of special maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below:
S.No. For Equipment Item Description Unit Quantity
Notwithstanding what is stated above, we further confirm that any additional special maintenance tools and tackles, required for the equipment under this package shall be furnished by us at no extra cost to the employer.
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/400kV/ Rajgarh /SS01/G1/R Attachment-4(B) SS01
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
(List of Special Maintenance Tools & Tackles)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We are furnishing below the list of special maintenance tools & tackles for various equipment under the subject package. The prices for these tools & tackles which are to be taken back after the completion of the work by us are not included in our lumpsum bid price. We further confirm that the list of special maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below:
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/400kV/ Rajgarh /SS01/G1/R Attachment-5 SS01
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
(Bought-out & Sub-contracted Items)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We hereby furnish the details of the items/ sub-assemblies of supply or services i.e. items, whose price is more than 10% of the Bid Price, we propose to buy for the purpose of furnishing and installation of the subject Package:
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Details of the proposed sub-contractor/sub-vendor
Name Nationality
We hereby declare that, we would not subcontract the erection portion of the contract without the prior approval of Employer.
We hereby furnish the details of the items/ sub-assemblies propose to supply from our own works (i.e. as direct transactions) in additiona to the supplies the same from other vendors (i.e. as Bought-out transactions) as detailed in the table given above.
Sl. No. Item Description Quantity proposed to be supplied Details of the plant from where supplies are proposed.
Name of Plant Address
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/400kV/ Rajgarh /SS01/G1/R Annexure I to Attachment-5 SS01
(Bought-out & Sub-contracted Items)
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Details of the proposed sub-contractor/sub-vendor
Name Nationality
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/400kV/ Rajgarh /SS01/G1/R Annexure I to Attachment-5 SS01
(Bought-out & Sub-contracted Items)
Sl. No. Item Description Details of the proposed sub-contractor/sub-vendor Details of the proposed sub-contractor/sub-vendor
Name Nationality
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/400kV/ Rajgarh /SS01/G1/R Attachment-5(A) SS01
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
(Items, Components, Raw Material, Services proposed to be sourced from Micro and Small Enterprises)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
1. We hereby furnish the details of the items, components, raw material, services which we propose to buy/avail from Micro and Small Enterprises (MSEs) for the purpose of completion of works under the subject package:
S.No. Item Description Quantity proposed to be bought/sub-contracted Name of Micro and Small Enterprises (MSEs)
Name & Address Category
2. The above is a list of items we propose to procure from MSEs. However, based on the situations during the execution of the contract, the above list may undergo changes. We hereby confirm that the details regarding actual procurement from MSEs carried out by us, as per the format provided at Section VI, Forms and Procedures, Volume-I of bidding documents, shall be submitted along with the bills for payment against supplies made/works done during execution of contract. .
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/400kV/ Rajgarh /SS01/G1/R Attachment-6 SS01
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
(Alternative, Deviations and Exceptions to the Provisions)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
The bidder shall itemize any deviation from the Specifications included in his bid. Each item shall be listed (separate sheets may be used and enclosed with this Attachment) with the following information:
Sl. No. Reference clause in the Specifications Deviation Cost of withdrawal of the deviation
The above deviations and variations are exhaustive. We confirm that we shall withdraw the deviations proposed by us at the cost of withdrawal indicated in this attachment, failing which our bid may be rejected and Bid Security forfeited.
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/400kV/ Rajgarh /SS01/G1/R Annexure I toAttachment-6 SS01
(Alternative, Deviations and Exceptions to the Provisions)
Sl. No. Reference clause in the Specifications Deviation Cost of withdrawal of the deviation
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/400kV/ Rajgarh /SS01/G1/R Attachment-7 SS01
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
(Details of Alternative Bid)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
No Alternative Bid
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/400kV/ Rajgarh /SS01/G1/R Attachment-9 SS01
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
(Work Completion Schedule)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We hereby declare that the following Work Completion Schedule shall be followed by us in furnishing and installation of the subject Package i.e., 400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC for the period commencing from the effective date of Contract to us :
Sl. No. Description of Work Period in months from the effective date of Contract
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
1 Detailed Engineering and drawing submission
a) commencement
2 Procurement of equipment/ components & assembly
a) commencement
a) commencement
4 Manufacturing
a) commencement
5 Shipments & Delivery
a) commencement
6 Establishment of site office
7 Installation at Site
a) commencement
8 Testing & Pre-commissioning
a) commencement
9 Trial Operation
a) commencement
Date : Printed Name :
Place : Designation :
Note : Bidders to enclose a detailed network covering all the activities to be undertaken for completion of the project indicating key dates for various milestones for each phase constituent-wise.
Specification No. :TBCB/400kV/ Rajgarh /SS01/G1/R Attachment-10 SS01
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
(Guarantee Declaration)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We conform that the equipments offered shall have minimum (or a maximum, as the case may be) performance specified in Technical Specification. We further guarantee the performance/efficiency of the equipments in response to the Technical Specifications.
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/400kV/ Rajgarh /SS01/G1/R Attachment-11 SS01
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
(Information regarding Ex-employees of POWERGRID in our Organisation)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We declare that we are aware of and have gone through the “Code of Business Conduct and Ethics for Senior Management Personnel”1 and “Code of Business Conduct and Ethics for Board Members”1 of POWERGRID (hereinafter referred to as the “Code of Conduct”). We further understand that as per the “Code of Conduct”, Senior Management Personnel including Board Members, who have retired/resigned from POWERGRID, shall not accept any appointment or post, as detailed in the referred “Code of Conduct”, within 1 year from the date of cessation of service/directorship unless approved by the Competent Authority. Accordingly, we hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
*In case the date of joining in the bidder’s organization of such ex-employee is within 1 year from the date of retirement/resignation from POWERGRID, No Objection Certificate/ approval from the Competent Authority must be furnished along with the bid or subsequent through clarification pursuant to ITB Clause 21.
In case of non-submission of No Objection Certificate/approval of the Competent Authority, as required, We understand that POWERGRID shall deal with such cases as per its Policy and procedures in vogue, which may also result in rejection of our bid. We also confirm that POWERGRID shall be the sole judge in this regard. We further declare that any misrepresentation or submission of false/forged documents/information in this regard shall be dealt with as per the provisions of the Integrity Pact and/or the Bidding Documents and/or POWERGRID’s policy and procedures.
Date : Printed Name :
Place : Designation :
Note: 1. “Code of Business Conduct and Ethics for Senior Management Personnel” and “Code of Business Conduct and Ethics for Board Members” are available on POWERGRID’s website https://www.powergridindia.com. 2. The information in similar format should be furnished for each partner of joint venture in case of joint venture bid. 3. In case bidder has furnished no details on ex-employees of POWERGRID or has left blank or has indicated ‘-‘ against the same, it shall be deemed that they have not employed any such person in their organization.
Specification No. :TBCB/400kV/ Rajgarh /SS01/G1/R Attachment-12 SS01
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
(Price Adjustment Data)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We hereby furnish the relevant details pertaining to the price adjustment provisions for equipment as specified in your specifications and documents for the 400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPCThe necessary documentary evidence are enclosed :
Sl. No. Name of Materials Value of co-efficient Name of the published index Value of index
WE HAVE QUOTED OUR BID PRICE ON FIRM PRICE BASIS.
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/400kV/ Rajgarh /SS01/G1/R Attachment-13 SS01
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
(Declaration regarding Social Accountability)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We conform that we stand committed to comply to all requirements of Social Accountability Standards i.e., SA8000 (latest Standard available at www.sa-intl.org) and maintain the necessary records.
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/400kV/ Rajgarh /SS01/G1/R Attachment-14 SS01
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
Integrity Pact is annexed herewith this Volume.
Date : Printed Name :
Place : Designation :
Instruction for printing & submitting Integrity Pact
1. The requisite format of Integrity Pact is getting generated automatically and displayed here below.
2. Take print out of first page on a non-judicial stamp paper of Rs. 100/- and other seven pages on plain A4 size paper. Such two sets shall be prepared by the bidder.
3. All the pages of both the copies of the Integrity Pact shall be signed by the authorised representative of the bidder and duly stamped.
4. Both the original copies shall be submitted by the bidder in the form of Hard Copy as part of the first envelope before due date & time of submission of the bid.
5. For further details bidders may please refer ITB Clause 9.3 (0).
Power Grid Corporation of India Limited
having its Registered Office at B-9, Qutab Institutional Area, Katwaria Sarai, New Delhi – 110016 hereinafter referred to as
having its Registered Office at
hereinafter referred to as
"The Bidder/Contractor"
POWERGRID intends to award, under laid-down organisational procedures, contract(s) for 400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC Package and Specification Number TBCB/400kV/ Rajgarh /SS01/G1/R .POWERGRID values full compliance with all relevant laws of the land, rules, regulations, economic use of resources, and of fairness / transparency in its relations with its Bidders/ Contractors.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 1 of 8
In order to achieve these goals, POWERGRID and the above named Bidder/Contractor enter into this agreement called 'Integrity Pact' which will form a part of the bid.
It is hereby agreed by and between the parties as under:
Section I - Commitments of POWERGRID
(1) POWERGRID commits itself to take all measures necessary to prevent corruption and to observe the following principles :
a) No employee of POWERGRID, personally or through family members, will in connection with the tender, or the execution of the contract, demand, take a promise for or accept, for him/herself or third person, any material or other benefit which he/she is not legally entitled to.
b) POWERGRID will, during the tender process treat all Bidder(s) with equity, fairness and reason. POWERGRID will in particular, before and during the tender process, provide to all Bidder(s) the same information and will not provide to any Bidder(s) confidential/ additional information through which the Bidder(s) could obtain an advantage in relation to the tender process or the contract execution.
c) POWERGRID will exclude from evaluation of Bids its such employee(s) who has any personal interest in the Companies/Agencies participating in the Bidding/Tendering process and all known prejudiced persons.
(2) If POWERGRID obtains information on the conduct of any of its employee which is a criminal offence under the IPC / PC Act , or if there be a substantive suspicion in this regard, POWERGRID will inform its Chief Vigilance Officer and in addition disciplinary actions can be initiated under POWERGRID’s Rules.
Section II - Commitments of the Bidder/Contractor
(1) The Bidder/Contractor commits itself to take all measures necessary to prevent corruption. The Bidder/Contractor commits itself to observe the following principles during its participation in the tender process and during the contract execution:
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 2 of 8
a) The Bidder/Contractor will not, directly or through any other person or firm, offer, promise or give to any of POWERGRID's employees involved in the tender process or the execution of the contract or to any third person any material or other benefit which it is not legally entitled to, in order to obtain in exchange an advantage of any kind whatsoever during the tender process or during the execution of the contract.
b) The Bidder/Contractor will not enter into any illegal or undisclosed agreement or understanding, whether formal or informal with other Bidders/Contractors. This applies in particular to prices, specifications, certifications, subsidiary contracts, submission or non-submission of bids or actions to restrict competitiveness or to introduce cartelization in the bidding process.
c) The Bidder/Contractor shall not pass any information provided by POWERGRID as part of business relationship to others and shall not commit any offence under PC / IPC Act.
d) The Bidder/Contractor of foreign origin shall disclose the name and address of the Agents/representatives in India, if any, involved directly or indirectly in the Bidding. Similarly, the Bidder/Contractor of Indian Nationality shall furnish the name and address of the foreign principals, if any, involved directly or indirectly in the Bidding.
e) The Bidder/Contractor will, when presenting his bid, disclose any and all payments made, or committed to or intends to make to agents, brokers or any other intermediaries in connection with the award of the contract and/or with the execution of the contract.
f) The Bidder/Contractor will not misrepresent facts or furnish false/forged documents/information in order to influence the bidding process or the execution of the contract to the detriment of POWERGRID.
g) The Bidder/Contractor shall ensure adoption of Integrity Pact by its Sub-contractors and shall be responsible for the same.
(2) The Bidder/Contractor will not instigate third persons to commit offences outlined above or be an accessory to such offences.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 3 of 8
Section III- Disqualification from tender process and exclusion from future contracts
(1) If the Bidder, before contract award, has committed a transgression through a violation of Section II or in any other form such as to put his reliability or credibility as Bidder into question, POWERGRID may disqualify the Bidder from the tender process or terminate the contract, if already signed, for such reason.
(2) If the Bidder/Contractor has committed a transgression through a violation of Section II such as to put his reliability or credibility into question, POWERGRID may, after following due procedures, ban /blacklist the Bidder/Contractor in line with POWERGRID’s policy for “Black-Listing of Firms / Banning of Business”. The imposition and duration of the ban will be determined by the severity of the transgression. The severity will be determined by the circumstances of the case, in particular the number of transgressions, the position of the transgressors within the company hierarchy of the Bidder/Contractor and the amount of the damage. The ban will be imposed for a maximum of 3 years.
(3) If the Bidder/Contractor can prove that he has restored/recouped the damage caused by him and has installed a suitable corruption prevention system, POWERGRID may revoke the ban prematurely.
Section IV - Liability for violation of Integrity Pact
(1) If POWERGRID has disqualified the Bidder from the tender process prior to the award under Section III, POWERGRID is entitled for forfeiture of the Bid Guarantee under the Bid.
(2) If POWERGRID has terminated the contract under Section III or if POWERGRID is entitled to terminate the contract under Section III, POWERGRID shall be entitled to forfeit the Contract Performance Guarantee of this contract, in full or part thereof as may be decided, besides resorting to other remedies under the contract.
Section V- Previous Transgression
(1) The Bidder shall disclose in its Bid any transgressions occurred in the last 10 years with any other Public Sector Undertaking or Government Department or any other Company, in any country, that may impinge on the Anti-corruption principle.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 4 of 8
(2) If the Bidder makes incorrect statement on this subject, it can be disqualified from the tender process or the contract, if already awarded, can be terminated for such reason and further action can be taken in line with POWERGRID’s policies.
Section VI - Equal treatment to all Bidders / Contractors
(1) POWERGRID will enter into agreements with identical conditions as this one with all Bidders.
(2) POWERGRID will disqualify from the tender process any bidder who does not sign this Pact or violate its provisions.
Section VII - Punitive Action against violating Bidders / Contractors
If POWERGRID obtains knowledge of conduct of a Bidder or a Contractor or its subcontractor or of an employee or a representative or an associate of a Bidder or Contractor or his Subcontractor which constitutes corruption, or if POWERGRID has substantive suspicion in this regard, POWERGRID will inform the Chief Vigilance Officer (CVO).
(*)Section VIII - Independent External Monitor/Monitors
(1) POWERGRID has appointed a panel of Independent External Monitors (IEMs) for this Pact with the approval of Central Vigilance Commission (CVC), Government of India. The names of the IEMs have been indicated in the Bidding Documents.
(2) The panel of IEMs shall review independently and objectively, whether and to what extent the parties comply with the obligations under this agreement. The panel of IEMs has right of access to all project documentation. The panel of IEMs may examine any complaint received by them and submit a report to Chairman-cum-Managing Director, POWERGRID, giving joint findings, at the earliest. The panel of IEMs may also submit a report directly to the CVO and the CVC, in case of suspicion of serious irregularities attracting the provisions of the PC Act.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 5 of 8
(3) The IEM is not subject to instructions by the representatives of the parties and performs his functions neutrally and independently. He / She reports to the Chairman-cum-Managing Director, POWERGRID.
(4) The Bidder(s)/Contractor(s) accepts that the IEM has the right to access without restriction to all documentation of POWERGRID related to this contract including that provided by the Contractor/Bidder. The Bidder/Contractor will also grant the IEM, upon his / her request and demonstration of a valid interest, unrestricted and unconditional access to their documentation. The same is applicable to Subcontractors. The IEM is under contractual obligation to treat the information and documents of the Bidder(s)/Contractor(s)/Subcontractor(s) with confidentiality.
(5) POWERGRID will provide to the IEMs information as sought by him / her which could have an impact on the contractual relations between POWERGRID and the Bidder/Contractor related to this contract. The IEMs shall also sign declaration on ’Non-Disclosure of Confidential Information’ and of ‘Absence of Conflict of Interest’. In case of any conflict of interest arising at a later date, the IEM shall inform Chairman-cum-Managing Director, POWERGRID and recuse himself/herself from that case
(6) As soon as the IEM notices, or believes to notice, a violation of this agreement, he / she will so inform the Chairman-cum-Managing Director, POWERGRID and request the Chairman-cum-Managing Director, POWERGRID to discontinue or take corrective action, or to take other relevant action. The IEM can in this regard submit non-binding recommendations. Beyond this, the IEM has no right to demand from the parties that they act in a specific manner, refrain from action or tolerate action. However, the IEM shall give an opportunity to POWERGRID and the Bidder/Contractor, as deemed fit, to present its case before making its recommendations to POWERGRID.
(7) The IEM will submit a written report to the Chairman-cum-Managing Director, POWERGRID within 8 to 10 weeks from the date of reference or intimation to him by POWERGRID and, should the occasion arise, submit proposals for correcting problematic situations.
(8) If the IEM has reported to the Chairman-cum-Managing Director, POWERGRID, a substantiated suspicion of an offence under PC / IPC Act, and the Chairman-cum-Managing Director, POWERGRID has not, within the reasonable time taken visible action to proceed against such offence or reported it to the CVO, the Monitor may also transmit this information directly to the CVC, Government of India.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 6 of 8
(9) While representing any matter in relation to the Integrity pact inter-alia including its transgression to the panel of IEMs, POWERGRID and Bidder/Contractor shall not approach the court of law and await the decision of the IEM in the matter.
(10) The word ‘IEM’ would include both singular and plural.
(*) This Section shall be applicable for only those packages wherein the IEMs have been identified in Section – I : Invitation for Bids and/or Clause ITB 9.3 in Section – III: Bid Data Sheets of Conditions of Contract, Volume-I of the Bidding Documents.
Section IX - Pact Duration
This Pact begins when both parties have legally signed it. It expires for the Contractor after the closure of the contract and for all other Bidder's six month after the contract has been awarded.
Section X - Other Provisions
(1) This agreement is subject to Indian Law. Place of performance and jurisdiction is the establishment of POWERGRID. The Arbitration clause provided in the main tender document / contract shall not be applicable for any issue / dispute arising under Integrity Pact.
(2) Changes and supplements as well as termination notices need to be made in writing. Side agreements have not been made.
(3) If the Contractor is a partnership firm or a consortium or Joint Venture, this agreement must be signed by all partners, consortium members and Joint Venture partners.
(4) Nothing in this agreement shall affect the rights of the parties available under the General Conditions of Contract (GCC) and Special Conditions of Contract (SCC).
(5) Issues like Warranty/Guarantees etc. shall be outside the purview of IEMs.
(6) Views expressed or suggestions/submissions made by the parties and the recommendations of the CVO/IEM# in respect of the violation of this agreement, shall not be relied on or introduced as evidence in the arbitral or judicial proceedings (arising out of the arbitral proceedings) by the parties in connection with the disputes/differences arising out of the subject contract.
# CVO shall be applicable for packages wherein IEM are not identified in Section IFB/BDS of Condition of Contract, Volume-I. IEM shall be applicable for packages wherein IEM are identified in Section IFB/BDS of Condition of Contract, Volume-I.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 7 of 8
(7) Should one or several provisions of this agreement turn out to be invalid, the remainder of this agreement remains valid. In this case, the parties will strive to come to an agreement to their original intentions.
Signature Signature
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
(Office Seal) (Office Seal)
Designation : Designation :
Witness 1 : Witness 1 :
Designation : Designation :
Witness 1 : Witness 1 :
Designation : Designation :
Integrity Pact Page 8 of 8
Specification No.: TBCB/400kV/ Rajgarh /SS01/G1/R Attachment-15 SS01
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
Option for Initial Advance (either Interest Bearing Initial Advance or No Initial Advance) and Information for E – payment, PF details and declaration for Micro/Small and Medium Enterprise
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
I We have read the provisions in the Bidding Documents regarding furnishing the option for advance payment. Accordingly, as per ITB Clause 9.3 as provided in Section BDS, Section III, Vol.-I of the Bidding Documents, we hereby confirm to opt the following:
Interest Bearing Initial Advance
Supply Portion:
Services Portion:
II We are furnishing the following details of Statutory Registration Numbers and details of Bank for electronic payment.
1. Name of the Supplier/ Contractor in whose favour payment is to be made
2. Address with PIN Code and State
Registered Office:
Correspondence Address:
3(a). Status – Company/others
[Declaration of Micro/ Small/ Medium Enterprise under Micro/ Small & Medium Enterprises Development Act 2006, if applicable]
3 (b). Are you a MSE owned by SC/ST* entrepreneurs in line with Public Procurement Policy for Micro and Small Enterprises (MSEs) order 2012 including subsequent amendment /notification/order (Indicate Yes/No) Note: Documentary evidence is to be attached. Please refer remarks at the end of the Attachment.
3 (c). If 3(b) is 'Yes', please mentiom whether you are (Proprietary MSE/ Partnership MSE/Private Limited Company) owned by SC/ST Entrepreneurs.
3 (d). Are you a MSE owned by a women in line with Public Procurment Policy for Micro and Small Enterprises (MSEs) order 2012, Public Procurment Policy for Micro & Small Enterprises (MSEs) Amendment Order 2018 including subsequent amendment / notification/order . (Indicate Yes/No) Note: Documentary evidence is to be attached.
4. Permanent Account (PAN) No.
5. GSTIN Numbers
I. GSTIN in the Sates/UT from where the supply of goods take place
Name of the States/UT GSTIN number
II. GSTIN in the States/UT where the supply for services take place (states where sites under the subject package is situated)
Name of the States/UT GSTIN number
10. PF Regional Office covered (with Address)
11. Name of Contact Person
12. Contact Details
13. Bank Details for Electronic Payment
Name of the Bank:
Address of Branch:
Type of Account:
Type of Account: Current Account
14. 9 digit MICR code printed at bottom in middle, next to cheque no.
15. IFSC (for RTGS)/NEFT Code (to be obtained from the Bank) Sample Cancelled Cheque to be enclosed
We hereby declare that the above information are true and correct and we agree that the payment on account of this Contract, in the event of award, be made in the above account maintained in the above mentioned Bank.
*The definition of MSEs owned by SC/ST is as given under:
a. In case of proprietary MSE, proprietor(s) shall be SC /ST.
b. In case of partnership MSE, the SC/ST partners shall be holding at least 51% shares in the unit.
c. In case of Private Limited companies, at least 51% share shall be held by SC/ST promoters.
Documentary evidence: Please provide scanned copy(ies) of the SC/ST certificate(s) issued by District Authority as applicable for SC/ST MSE category as per (a), (b) or (c) above.
Date : ……………. Printed Name : …………………….
Place : ………………. Designation : ……………………
Specification No. :TBCB/400kV/ Rajgarh /SS01/G1/R Attachment-16 SS01
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
(Additional Information)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
In support of the additional information required as per ITB Sub-Clause 9.3 (p) of the Bidding Documents, we furnish herewith our data/details/documents etc., alongwith other information, as follows (the stipulations have been reproduced in italics for ready reference):
1.0 The Bidder shall furnish
A certificate from their Banker(s) (as per prescribed formats in Form 16, Section-VI: Sample Forms and Procedures) indicating various fund based/non fund based limits sanctioned to the Bidder and the extent of utilization as on date. Such certificate should have been issued not earlier than three months prior to the date of bid opening. Wherever necessary the Employer may make queries with the Bidders’ Bankers. [Reference ITB clause 9.3(p)(i)]
1.1 In accordance with 1.0, certificate(s) from banker as per requisite format, indicating various fund based/non fund based limits sanctioned to the bidder or each member of the joint venture and the extent of utilization as on date is/are enclosed, as per the following details:
Name of the Bidder (Sole Bidder)
Name of the Banker by whom certificate issued
Date of certificate (should not be earlier than 3 months prior to date of bid opening)
Whether fund based/non fund based limits are indicated in the certificate
Whether extent of utilization is indicated in the certificate
1.2 The Bidder should accordingly also provide the following information/documents
(i) Details of Banker:
Address of Banker
Contact Name and Title
(ii) As per para 1.0, Authorization Letter(s) from the bidder (in case of JV bidder, from all the partners) addressed to the Banker(s), authorizing POWERGRID to seek queries about the bidder with the Banker(s) and advising the Banker(s) to reply the same promptly, is/are enclosed as per following details:
Sl. No. Letter Ref. Date Addressed to (name of the Bank)
(iii) Details of Provident Fund Code Number of the Bidder
2.0 Litigation History
The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years. A consistent history of awards involving litigation against the Bidder or any partner of JV may result in rejection of Bid. [Reference ITB clause 9.3(p)(ii)]
2.1 Details of litigation history resulting from Contracts completed or under execution by the bidder over the last five years
Year Name of client, cause of litigation/arbitration and matter in dispute Details of Contract and date Award for or against the bidder Disputed amount
3.0 Details regarding previous transgressions of Integrity Pact
The bidder should provide detailed information on any transgression of Integrity Pact that occurred in the last 10 years with any other Public Sector Undertaking or Government Department or any other Company, in any country.
3.1 Details regarding previous transgressions of Integrity Pact that occurred in the last 10 years
Year Name of client Details of Transgression of Integrity Pact by the bidder
4.0 OTHER INFORMATION
4.1 Current Contract Commitments of works in progress
Bidders (individual firms or each partners of JV) should provide information on their current commitments on all contracts that have been awarded, or for which a letter of intent or acceptance has been received, or for contracts approaching completion, but for which an unqualified, full completion certificate has yet to be issued.
Details of Contract Value of outstanding work (Rs.) Estimated completion date
4.2 Financial Data:
Details Actual (Previous five years) Projection for next five years
Total Liability
Current Liability
Profit before taxes
Profit after taxes
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/400kV/ Rajgarh /SS01/G1/R Attachment-16
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
(Additional Information)
Name(s) and Addresse(s) of other partner(s) To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
In support of the additional information required as per ITB Sub-Clause 9.3 (p) of the Bidding Documents, we furnish herewith our data/details/documents etc., alongwith other information, as follows (the stipulations have been reproduced in italics for ready reference):
1.0 The Bidder shall furnish
A certificate from their Banker(s) (as per prescribed formats in Form 16, Section-VI: Sample Forms and Procedures) indicating various fund based/non fund based limits sanctioned to the Bidder and the extent of utilization as on date. Such certificate should have been issued not earlier than three months prior to the date of bid opening. Wherever necessary the Employer may make queries with the Bidders’ Bankers. [Reference ITB clause 9.3(p)(i)]
1.1 In accordance with 1.0, certificate(s) from banker as per requisite format, indicating various fund based/non fund based limits sanctioned to the bidder or each member of the joint venture and the extent of utilization as on date is/are enclosed, as per the following details:
Name of the Banker by whom certificate issued
Date of certificate (should not be earlier than 3 months prior to date of bid opening)
Whether fund based/non fund based limits are indicated in the certificate
Whether extent of utilization is indicated in the certificate
1.2 The Bidder should accordingly also provide the following information/documents
(i) Details of Banker:
Address of Banker
Contact Name and Title
(ii) As per para 1.0, Authorization Letter(s) from the bidder (in case of JV bidder, from all the partners) addressed to the Banker(s), authorizing POWERGRID to seek queries about the bidder with the Banker(s) and advising the Banker(s) to reply the same promptly, is/are enclosed as per following details:
Sl. No. Letter Ref. Date Addressed to (name of the Bank)
2.0 Litigation History
The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years. A consistent history of awards involving litigation against the Bidder or any partner of JV may result in rejection of Bid. [Reference ITB clause 9.3(p)(ii)]
2.1 Details of litigation history resulting from Contracts completed or under execution by the bidder over the last five years
Year Name of client, cause of litigation/arbitration and matter in dispute Details of Contract and date Award for or against the bidder Disputed amount
3.0 OTHER INFORMATION
3.1 Current Contract Commitments of works in progress
Bidders (individual firms or each partners of JV) should provide information on their current commitments on all contracts that have been awarded, or for which a letter of intent or acceptance has been received, or for contracts approaching completion, but for which an unqualified, full completion certificate has yet to be issued.
Details of Contract Value of outstanding work (Rs.) Estimated completion date
3.2 Financial Data:
Details Actual (Previous five years) Projection for next five years
Total Liability
Current Liability
Profit before taxes
Profit after taxes
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/400kV/ Rajgarh /SS01/G1/R Attachment-16
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
(Additional Information)
Name(s) and Addresse(s) of other partner(s) To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
In support of the additional information required as per ITB Sub-Clause 9.3 (p) of the Bidding Documents, we furnish herewith our data/details/documents etc., alongwith other information, as follows (the stipulations have been reproduced in italics for ready reference): Reference ITB clause 9.3(p)(ii)
1.0 The Bidder shall furnish
A certificate from their Banker(s) (as per prescribed formats in Form 16, Section-VI: Sample Forms and Procedures) indicating various fund based/non fund based limits sanctioned to the Bidder and the extent of utilization as on date. Such certificate should have been issued not earlier than three months prior to the date of bid opening. Wherever necessary the Employer may make queries with the Bidders’ Bankers. [Reference ITB clause 9.3 (p)(i)]
1.1 In accordance with 1.0, certificate(s) from banker as per requisite format, indicating various fund based/non fund based limits sanctioned to the bidder or each member of the joint venture and the extent of utilization as on date is/are enclosed, as per the following details:
Name of the Banker by whom certificate issued
Date of certificate (should not be earlier than 3 months prior to date of bid opening)
Whether fund based/non fund based limits are indicated in the certificate
Whether extent of utilization is indicated in the certificate
1.2 The Bidder should accordingly also provide the following information/documents
(i) Details of Banker:
Name of Banker `
Address of Banker
Contact Name and Title
(ii) As per para 1.0, Authorization Letter(s) from the bidder (in case of JV bidder, from all the partners) addressed to the Banker(s), authorizing POWERGRID to seek queries about the bidder with the Banker(s) and advising the Banker(s) to reply the same promptly, is/are enclosed as per following details:
Sl. No. Letter Ref. Date Addressed to (name of the Bank)
2.0 Litigation History
The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years. A consistent history of awards involving litigation against the Bidder or any partner of JV may result in rejection of Bid.
2.1 Details of litigation history resulting from Contracts completed or under execution by the bidder over the last five years
Year Name of client, cause of litigation/arbitration and matter in dispute Details of Contract and date Award for or against the bidder Disputed amount
3.0 OTHER INFORMATION
3.1 Current Contract Commitments of works in progress
Bidders (individual firms or each partners of JV) should provide information on their current commitments on all contracts that have been awarded, or for which a letter of intent or acceptance has been received, or for contracts approaching completion, but for which an unqualified, full completion certificate has yet to be issued.
Details of Contract Value of outstanding work (Rs.) Estimated completion date
3.2 Financial Data:
Details Actual (Previous five years) Projection for next five years
Total Liability
Current Liability
Profit before taxes
Profit after taxes
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/400kV/ Rajgarh /SS01/G1/R Attachment-17 SS01
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
(Declaration for tax exemptions, reductions, allowances or benefits)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
1 We confirm that we are solely responsible for obtaining following tax exemptions, reductions, allowances or benefits in respect of supplies under the subject package, in case of award. We further confirm that we have considered the same in our bid thereby passing on the benefit to POWERGRID while quoting our prices. In case of our failure to receive such benefits, partly or fully, for any reason whatsoever, the Employer will not compensate us.
2 We are furnishing the following information required by the Employer for issue of requisite certificate if and as permitted in terms of the applicable Govt. of India policies/procedures (in case of award):
Applicable Act, Notification No. and Clause Ref. No. Sl. No. Description of item on which applicable Country of origin Remarks, if any
(The requirements listed above are as per current Notification of Govt. of India indicated above. These may be modified, if necessary, in terms of the Notifications.)
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/400kV/ Rajgarh /SS01/G1/R Attachment-17 SS01
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contract Services
Name : …… ……. …….. …… ……. …….. Power Grid Corporation of India Ltd.,
Address : …… ……. …….. …… ……. …….. "Saudamini", Plot No. 2, Sector 29
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/400kV/ Rajgarh /SS01/G1/R Attachment-17 SS01
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/400kV/ Rajgarh /SS01/G1/R Attachment-18 SS01
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
Safety Pact is annexed herewith this Volume.
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/400kV/ Rajgarh /SS01/G1/R Attachment-19 SS01
400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
Further, we hereby confirm that except as mentioned in the Attachment – 6 (Alternative, Deviations and Exceptions to the Provisions) hereof forming part of our First Envelope :
Date : Printed Name :
Place : Designation :
Specification No TBCB/400kV/ Rajgarh /SS01/G1/R Bid Form 1st Envelope (Revised) 1 one 1 st 1 January
2 two 2 nd 2 February
BID FORM (First Envelope) 3 three 3 rd 3 March
4 four 4 th 4 April
Bid Proposal Ref. No. 5 five 5 th 5 May
Date : 6 six 6 th #VALUE! 6 June
7 seven 7 th #VALUE! 7 July
To: 8 eight 8 th #VALUE! 8 August
Contract Services 9 nine 9 th #VALUE! 9 September
Power Grid Corporation of India Ltd., 10 ten 10 th 10 October
"Saudamini", Plot No. 2, Sector 29 11 eleven 11 th 11 November
Gurgaon (Haryana) - 122001 12 twelve 12 th 12 December
13 thirteen 13 th
14 fourteen 14 th
Name of Contract : 400kV Substation Package (SS01) for establishment of 400/220kV substation at Pachora SEZ PP (new) (including 1x125MVAR, 420kV Bus Reactor and 2x80MVAR, 420kV line Reactors) & extension of 400kV Bhopal (Sterlite) associated with “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I” through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC 15 fifteen 15 th
Dear Ladies and/or Gentlemen, Enter details here. 16 sixteen 16 th
1.0 Having examined the Bidding Documents, including Amendment Nos. ...[Enter the Amendment]… dated …[Enter the Date in dd-mm-yyyy]… the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial operation, Performance & Guarantee Test as per the provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently). ...[Enter the Amendment]… …[Enter the Date in dd-mm-yyyy]… the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial operation, Performance & Guarantee Test as per the provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently). 17 seventeen 17 th
1.1 We meet the eligibility requirements and have no conflict of interest in accordance with ITB Clause 2.
2.0 Attachments to the Bid Form (First Envelope) Bank Draft 18 eighteen 18 th
In line with the requirement of the Bidding Documents, we enclose herewith the following Attachments: Enter details here. Pay Order 19 nineteen 19 th
(a) Attachment 1(SS01) : NOT APPLICABLE Bank Guarantee INR Please note that if validity of bid security is less than 250 days, your bid may be rejected Banks certified Cheque Zero 20 twenty 20 th
Online Payment Acknowledgement towards Bid Security for a sum of INR Enter details here.
OR documentary evidence in support of exemption of Bid Security, in separate envelope in accordance with clause 13.1 of ITB, Section-II Online Payment INR
(b) Attachment 2(SS01) : A power of attorney duly authorized by a Notary Public indicating that the person(s) signing the bid have the authority to sign the bid and thus that the bid is binding upon us during the full period of its validity in accordance with the ITB Clause 14. Bank Guarantee (0) 21 st
(c) Attachment 3(SS01) : The documentary evidence that we are eligible to bid in accordance with ITB Clause 2. Further, in terms of ITB Clause 9.3 (c) & (e), the qualification data has been furnished as per your format enclosed with the bidding documents Attachment-3(QR). Sole Bidder Online Payment 22 th
Further, the required Joint Venture Agreement signed by us and our Partners has also been furnished as per your format Attachment-3(JV). 0 0 Applicable 23 th
Further the required deed of Joint Undertaking signed by us and Tower Manufacturer has also been furnished as per your format. Not Applicable 24 th
(d) Attachment 4(SS01) : The documentary evidence establishing in accordance with ITB Clause 3, Vol.-I of the Bidding Documents that the facilities offered by us are eligible facilities and conform to the Bidding Documents has been furnished as Attachment 4. A list of Special Tools & Tackles to be used by us for erection, testing & Commissioning and to be handed over to Employer, the cost of which is included is our Bid Price, is also enclosed as per your format as Attachment 4A. A list of Special Tools & Tackles to be brought by the contractor for erection, testing & Commissioning and to be taken back after completion of work, whose cost in not included in our bid price, is enclosed as per your format as Attachment 4B. 25 th
(e) Attachment 5(SS01) : The details of all major items of services or supply which we propose subletting in case of award, giving details of the name and nationality of the proposed subcontractor/sub-vendor for each item. 26 th
(f) Attachment 5A(SS01) : (Items, Components, Raw Material, Services proposed to be sourced from Micro and Small Enterprises): The details of the items, components, raw material, services which is proposed to bought/availed from Micro and Small Enterprises for the purpose of completion of works.
(g) Attachment 6(SS01) : The variation and deviations from the requirements of the Conditions of Contract, Technical Specification and Drawings (excluding critical provisions as mentioned at clause 6.0 below) in your format enclosed with the Bidding Documents, including, inter alia, the cost of withdrawal of the variations and deviations indicated therein. 27 th
(h) Attachment 7(SS01) : The details of Alternative Bids made by us indicating the complete Technical Specifications and the deviation to contractual and commercial conditions. (Not Applicable) 28 th
(i) Attachment 8(SS01) : Manufacturer’s Authorisation Forms. 29 th
(j) Attachment 9(SS01) : Work Completion Schedule. 30 th
(k) Attachment 10(SS01) : Guarantee Declaration. 31 st
(l) Attachment 11(SS01) : Information regarding ex-employees of Employer in our firm.
(m) Attachment 12(SS01) : Filled up information regarding Price Adjustment Data as per the format enclosed in the bidding documents.
(n) Attachment 13(SS01) : Declaration regarding Social Accountability.
(o) Attachment 14(SS01) : Integrity Pact, in a separate envelope, duly signed on each page by the person signing the bid.
(p) Attachment 15(SS01) : Option for Initial Advance (either Interest Bearing Initial Advance or No Initial Advance) and Information for E – payment, PF details and declaration for Micro/Small and Medium Enterprise
(q) Attachment 16(SS01) : Additional Information.
(r) Attachment 17(SS01) : Declaration for tax exemptions, reductions, allowances or benefits
(s) Attachment 18(SS01) : Safety Pact
(t) Attachment 19(SS01) : Declaration.
(u) Attachment 20(SS01) : Declaration of Key Managerial Person jointly with Power of Attorney holder
(v) Attachment 21(SS01) : Authorization certificate issued by Domestic Manufacturer for selling Domestically Manufactured Iron &Steel Products
(w) Attachment 22(SS01) : Affidavit of Self certification regarding Domestic Value Addition in Iron & Steel Products
(x) Attachment 23(SS01) : Affidavit.
(y) Attachment 24(SS01) : Confirmation regarding furnishing Declaration regarding Non-Participation as a Bidding Company or as a member of any Bidding Consortium in Transmission Project under Tariff Based Competitive Bidding Route.
(z) Attachment 25((SS01) : Declaration by the Bidder regarding events encountered pursuant to ITB Clause 2.1 (All partners of the Joint Venture in case of Joint Venture bids)
(aa) Attachment 26(SS01) : Affidavit of Self certification regarding Minimum Local Content in line with PPP-MII order, if applicable
(ab) Attachment 27(SS01) : Certificate from statutory auditor or cost auditor of the company (in the case of companies) or from a practicing cost accountant or practicing chartered accountant (in respect of suppliers other than companies) giving the percentage of Local Content, in line with PPP-MII order, if applicable
(ac) Attachment 28((SS01) : Certification by the Bidder per DoE Order in line with ITB Clause 2.1
(ad) Attachment 29(SS01) : Bid Securing Declaration to be submitted by the Bidder.
(ae) Attachment 30(SS01) : Undertaking regarding submission of original/Hard copy part of the bid
3.0 We are aware that, in line with Clause No. 27.1 (ITB), our Second Envelope (Price Part) is liable to be rejected in case the same contains any deviation/omission from the contractual and commercial conditions and technical Specifications other than those identified in this First Envelope.
3.0 A * (applicable for MSE only) We are a Micro and Small Enterprise (MSE) registered with a designated Authority of GoI under the Public Procurement Policy for MSEs Order, 2012, Notification dated 01/06/2020 and 26/06/2020 read in conjunction with related notifications issued from time to time for such enterprises. Delete if not applicable
4.0 We confirm that except as otherwise specifically provided our Bid Prices in Second Envelope include all taxes, duties, levies and charges as may be assessed on us, our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
4.1 100% of applicable Taxes and Duties i.e. GST, which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents.
4.3 We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN, in all the states where the project is located and the states from which we shall make our supply of goods.
5.0 Construction of the Contract
5.1 We declare that we have studied Clause GCC 2.1 relating to mode of contracting for Domestic Bidders and we are making this proposal with a stipulation that you shall award us two separate Contracts viz ‘First Contract’ for ex-works supply of all equipment and materials including mandatory spares and ‘Second Contract’ for providing all the services i.e. inland transportation for delivery at site, insurance, unloading, storage, handling at site, installation, testing and commissioning including Trial operation in respect of all the equipment supplied under the ‘First Contract’ and other services specified in the Contract Documents. We declare that the award of two contracts, will not, in any way, dilute our responsibility for successful operation of plant/equipment and fulfillment of all obligations as per Bidding Documents and that both the Contracts will have a cross-fall breach clause i.e. a breach in one Contract will automatically be classified as a breach of the other contract which will confer on you the right to terminate the other contract at our risk and cost.
6.0 We have read the provisions of following clauses and confirm that the specified stipulations of these clauses are acceptable to us:
(a) ITB 13 Bid Security
(b) GCC 2.14 Governing Law
(c) GCC 5.1 Contractor’s Responsibilities
(d) GCC 8 Terms of Payment
(e) GCC 9.3 Performance Security
(f) GCC 10 Taxes and Duties
(g) GCC 21.2 Completion Time Guarantee
(h) GCC 22 Defect Liability
(i) GCC 23 Functional Guarantee
(j) GCC 25 Patent Indemnity
(k) GCC 26 Limitation of Liability
(l) GCC 38 Settlement of Disputes
(m) GCC 39 Arbitration
(n) Appendix 2 to Form of Contract Agreement Price Adjustment
Further we understand that deviation taken in any of the above clauses by us may make our bid non-responsive as per provision of bidding documents and be rejected by you.
7.0 We have noted the provisions of the Bidding Documents that POWERGRID intends to participate in the selection of Transmission Service Provider (TSP) for the “Transmission System for evacuation of power from RE projects in Rajgarh (1500MW) SEZ in Madhya Pradesh- Phase I’’ under Tariff Based Competitive Bidding (TBCB) Route. For this purpose, the bids have been invited by POWERGRID for the subject Package covering certain scope of work under the aforesaid TBCB Project. The qualified, lowest evaluated Bidder having requisite capacity and capability to perform the contract for the aforesaid Package(s) as per the provisions of the Bidding Documents shall be pre-selected, for the scope of work contained in the Bidding Documents, for associating with POWERGRID for the purpose of tariff bidding by POWERGRID in the RfP process of the BPC for the subject Project under TBCB route and, in case POWERGRID becomes successful Bidder, the successful Bidder for aforesaid mentioned Package(s) will be awarded the Contract for execution of scope of work contained in the Bidding Documents. An MOU shall be signed with the pre-selected Bidder prior to tariff bid submission by POWERGRID to BPC against its RfP process. This MOU shall, inter-alia, bind both POWERGRID and the pre-selected Bidder for associating on exclusive basis and maintaining strict confidentiality by the pre-selected Bidder of the prices, terms and conditions.
7.1 We undertake, if our bid is accepted, to commence the work immediately upon your Notification of Award to us, and to achieve the delivery of goods and related services within the time stated in the Bidding Documents.
8.0 If our bid is accepted, we undertake to provide a Performance Security in the form and amounts, and within the times specified in the Bidding Documents.
9.0 We agree to abide by this bid for a period of Six (06) months from the date fixed for opening of bids as stipulated in the Bidding Documents, and it shall remain binding upon us and may be accepted by you at any time before the expiration of that period.
10.0 Until a formal Contract is prepared and executed between us, this bid, together with your written acceptance thereof in the form of your Notification of Award shall constitute a binding contract between us.
11.0 We understand that you are not bound to accept the lowest or any bid you may receive.
12.0 Commissions or gratuities, if any, paid or to be paid by us to agents relating to this Bid, and to contract execution, if we are awarded the contract, are listed below:-
Name and address of agent Amount and Currency Purpose of Commission or gratuity
(If none, state “none”)
13.0 # (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions.
14.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of
Date : Printed Name :
Place : Designation :
In case of bid from a Joint Venture, name & designation of representative of JV partner is to be provided and Bid Form is also to be signed by him
Other Partner -1 Other Partner -2
Printed Name : Printed Name :
Designation : Designation :
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2(SS01) Power of Attorney. Bidders may use their own proforma for furnishing the required information with the bid.
Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2(SS01) Power of Attorney. Bidders may use their own proforma for furnishing the required information with the bid.
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html
~$_Covers -SS01.doc
doc • 0.00 MB
~WRL0001.tmp
tmp • 1.58 MB
~WRL0754.tmp
tmp • 0.16 MB
00_Covers -SS01.doc
doc • 1.58 MB
01- Section - I_IFB-SS01.doc
doc • 0.08 MB
02-Section - II ITB SSTE S&I Rev 5-DCB-Mjn.pdf
pdf • 1.95 MB
03-Section - III_BDS-SS01.docx
docx • 0.07 MB
04 -Annexure-A (BDS)-SS01.doc
doc • 0.07 MB
05 -Annexure-B (BDS)-SS01.docx
docx • 0.02 MB
06-Section - IV GCC -S&I Rev 3-DCB.pdf
pdf • 1.93 MB
07-Section - V_SCC-SS01.doc
doc • 0.16 MB
08-Appendix -I to SCC.doc
doc • 0.16 MB
09-Annexure-I to Section-V (SCC).docx
docx • 0.02 MB
10-Sample Forms and Procedures-SS01.doc
doc • 0.54 MB
Annexure II Specific Requirement_Rev 05_with Annexures.pdf
pdf • 9.08 MB
Annexure IV to Section Project-Tech specifications of HG fuse.pdf
pdf • 0.13 MB
Annexure-I to Section Project-List of Drawings.pdf
pdf • 0.35 MB
Annexure-III to Section Project-Breakup of Mandatory Spares.pdf
pdf • 0.30 MB
Section_Project Substation Package_SS01- Pachora.pdf
pdf • 1.28 MB
1.0 GTR Rev 15 .pdf
pdf • 7.12 MB
10.0 Air conditioning R4.pdf
pdf • 0.04 MB
Section-Switchgear-CB_Rev11.pdf
pdf • 0.61 MB
Section-Switchgear-INST_rev11.pdf
pdf • 1.00 MB
Section-Switchgear-ISO_Rev11B.pdf
pdf • 0.11 MB
Section-Switchgear-SA_Rev12.pdf
pdf • 0.34 MB
5.0 LT Switchgear R5.pdf
pdf • 0.47 MB
6.0 Battery&Charger R6.pdf
pdf • 1.05 MB
7.0 PLCC R5.pdf
pdf • 0.06 MB
8.0 Fire Protection Rev 6.pdf
pdf • 1.97 MB
9.0 Power & Control Cable Rev R6.pdf
pdf • 0.26 MB
11.0 Section_Switchyard Erection_Rev.10.pdf
pdf • 5.99 MB
12.0 CRP Rev 09.pdf
pdf • 0.37 MB
Section-Sub-station Automation_Rev04.pdf
pdf • 0.98 MB
Section-Sub-station Automation_STANDARD FACTORY SIMULATION TEST PLAN.pdf
pdf • 0.54 MB
14.0 DG Set Rev 5.pdf
pdf • 0.27 MB
15.0 Civil Works Rev 11A.pdf
pdf • 2.00 MB
15.0 Section Structure Rev 6.pdf
pdf • 0.10 MB
17.0 Lighting Specification Rev.07.pdf
pdf • 4.29 MB
17_Civil Works Rev 11A-Cor slip-1-07.01.21.pdf
pdf • 3.99 MB
18.0 Section Telecommunication Systems Rev 02.pdf
pdf • 1.78 MB
19.0 Section PMU Rev 0.pdf
pdf • 0.59 MB
20.0 LT Transformer-Rev05.pdf
pdf • 0.07 MB
420kV Reactor_REV_10.pdf
pdf • 3.92 MB
3.75 m wide ROAD.pdf
pdf • 0.44 MB
AC_DC_SLD-Model-Annex A.pdf
pdf • 0.38 MB
Architectural details of FFPH & water tank.pdf
pdf • 2.29 MB
Bhopal existing drawings_1 of 2.pdf
pdf • 6.79 MB
Bhopal existing drawings_2 of 2.pdf
pdf • 11.96 MB
Details of cable trench and cable trench road crossings.pdf
pdf • 0.63 MB
Details of drain.pdf
pdf • 2.24 MB
Details of Main entrance gate.pdf
pdf • 0.85 MB
Details of Pre-fabricated RCC Boundary wall.pdf
pdf • 4.29 MB
Details of SPR buidling.pdf
pdf • 1.62 MB
Details of switchyard gate.pdf
pdf • 1.20 MB
RAIL CUM ROAD.pdf
pdf • 1.30 MB
ROAD CULVERT.pdf
pdf • 1.50 MB
Security Hut Detials.pdf
pdf • 0.46 MB
Standard details for switchyard barbed wire fencing.pdf
pdf • 0.47 MB
Standard drawing for Rain water harvesting structr.pdf
pdf • 0.19 MB
Typical details of labour hut.pdf
pdf • 0.72 MB
Typical module.pdf
pdf • 0.14 MB
10-Attachemnt-26_ Affidavit for self-certifictaion_SS01.docx
docx • 0.02 MB
11-Attachment 27_Certificate by Auditor_SS01.docx
docx • 0.02 MB
12-Attachment 28- certifacte by bidder_SS01.docx
docx • 0.02 MB
13-Attachment-29(Bid securing Declaration)_SS01.docx
docx • 0.02 MB
14-Second Envelope - Bid Form and Price Schedule.xlsx
xlsx • 1.89 MB
15-Volume-III_Legends.pdf
pdf • 0.03 MB
1-First Envelope - Bid Form and Attachments_SS01.xlsx
xlsx • 1.25 MB
2-Attachment-3_Bidders Eligibility and Qualifications.doc
doc • 0.06 MB
3-Attachment-8_Manufacturer Authorisation Form_SS01.doc
doc • 0.03 MB
4-Attachment-18_SAFETY PACT_SS01.docx
docx • 0.03 MB
5- Attachment 20_KMP-Declaration_SS01.doc
doc • 0.04 MB
6-Attachment 21- Authorization certificate issued by Domestic Manufacturer_SS01.docx
docx • 0.02 MB
7-Attachemnt-22- Affidavit for self-certification_SS01.docx
docx • 0.02 MB
8-Attachment - 23 (Affidavit)_SS01.docx
docx • 0.02 MB
9-Attachment -25_Declaration regarding events encountered pursuant to ITB Clause 2.1_SS01.docx
docx • 0.03 MB
OBD_extn_letter_for_POWERGRID_portal_obde-V.docx
docx • 0.16 MB
Amendment-VII.doc
doc • 0.11 MB
OBD_extn_letter_for_POWERGRID_portal_obde-IV.docx
docx • 0.16 MB
Errata-II.doc
doc • 0.06 MB
OBD_extn_letter_for_POWERGRID_portal_obde-III.docx
docx • 0.16 MB
Amendment-VI.doc
doc • 0.06 MB
Errata-I.doc
doc • 0.07 MB
Amendment-V.doc
doc • 0.06 MB
Clarification-III_SS01_Rajgarh.xlsx
xlsx • 0.02 MB
Clarification-II.xlsx
xlsx • 0.02 MB
OBD_extn_letter_for_POWERGRID_portal_obde-II.docx
docx • 0.16 MB
Clarification-I_Technical_SS01_Rajgarh.xlsx
xlsx • 0.15 MB
OBD_extn_letter_for_POWERGRID_portal_obde-I.docx
docx • 0.16 MB
Attachment-30.docx
docx • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .