Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.6 LAccepted-AOC 24 1 2ND MAIN ROAD JAI NAGAR ARUMBAKKAM CHENNAI 600 106 | L1 | Accepted-AOC L1 | |
| 2 | L2₹33.9 L+₹3.6 L (11.9%)Rejected-AOC FLAT A GROUND FLOOR NO 3 SAM S NATHANEAL TOWERS WEST CLUB ROAD SHENOY NAGAR CHENNAI TAMIL NADU 600030 INDIA | CHENNAI | TAMIL NADU | 600030 | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | Vijay Shri Engineering L1 | JAI ENERGY ENGINEERS L2 |
|---|---|---|---|---|---|
| 1.00Spares for Hydraulic Boom luffing system valves and pumps for ECHS Reclaimers | |||||
| 1.01 | Pilot Operated Check valve
Capacity: 150 LPM
Pressure: 315 Bar
suitable to the existing REXROTH make valve | 1 | No | 1,32,000 ₹1,32,000 Lowest | 1,50,000 ₹1,50,000 |
| 1.02 | Counter balance valve assembly for manifold block
Capacity: 60 LPM
Pressure: 350 Bar
suitable to the existing Eaton Vickers make valve | 1 | No | 4,25,000 ₹4,25,000 Lowest | 4,86,000 ₹4,86,000 |
| 1.03 | Counter balance relief valve assembly for manifold block
Capacity: 50 LPM
Pressure: 420 Bar
suitable to the existing Eaton Vickers make valve | 1 | No | 4,25,000 ₹4,25,000 Lowest | 4,86,000 ₹4,86,000 |
| 1.04 | Direction control valve
Capacity: 50 LPM
Pressure: 420 Bar
suitable to the existing Eaton Vickers make valve | 1 | No | 1,32,000 ₹1,32,000 Lowest | 1,50,000 ₹1,50,000 |
| 1.05 | Pressure reducing valve
Capacity: 50 LPM
Pressure: 420 Bar
Valve suitable to the existing Eaton Vickers make. | 1 | No | 1,32,000 ₹1,32,000 Lowest | 1,50,000 ₹1,50,000 |
| 1.06 | Throttle and check valve
Capacity: 50 LPM
Pressure: 420 Bar
suitable to the existing REXROTH make valve | 1 | No | 1,32,000 ₹1,32,000 Lowest | 1,50,000 ₹1,50,000 |
| 1.07 | 1/2" BSP shutoff valve line mounting
Capacity: 50 LPM
Pressure: 420 Bar
suitable to the existing Eaton Vickers make Valve | 1 | No | 1,26,000 ₹1,26,000 Lowest | 1,45,000 ₹1,45,000 |
| 1.08 | Reclaimer boom luffing pump
VANE pump
Capacity: 64 LPM
Displacement 75cc
Speed: 1800 rpm
Pressure: 250 bar max / 315 bar peak Pressure.
Make: DENESION VELIJAN or Equivalent | 1 | No | 4,53,500 ₹4,53,500 Lowest | 5,18,500 ₹5,18,500 |
| 1.09 | Reclaimer slewing pump
Type: closed loop axial pistion pump
Capacity: 135 LPM
Displacement 75cc
Speed: 1800 rpm
Pressure: 250 bar max / 280 bar peak Pressure.
Make: SAUER DANFOSS or Equivalent | 1 | No | 10,70,000 ₹10,70,000 Lowest | 11,51,000 ₹11,51,000 |
Tender Value
Refer Docs
EMD Value
₹28,200
Closing Date
29 May 2025, 2:00 pmClosed
CE NCTPS-I
CE NCTPS-I
Supply of Hydraulic boom luffing system valves and pumps for ECHS Reclaimers
2025_EB_557522_1
CE-22/2025-26/NCTPS-I
Open Tender
Miscellaneous Goods
Supply
60 days
NCTPS-I CHENNAI
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹28,200
Yes
10 Oct 2025
13 May 2025
30 May 2025
13 May 2025
29 May 2025
13 May 2025
Amount
Spares for Hydraulic Boom luffing system valves and pumps for ECHS Reclaimers
Pilot Operated Check valve Capacity: 150 LPM Pressure: 315 Bar suitable to the existing REXROTH make valve
Counter balance valve assembly for manifold block Capacity: 60 LPM Pressure: 350 Bar suitable to the existing Eaton Vickers make valve
Counter balance relief valve assembly for manifold block Capacity: 50 LPM Pressure: 420 Bar suitable to the existing Eaton Vickers make valve
Direction control valve Capacity: 50 LPM Pressure: 420 Bar suitable to the existing Eaton Vickers make valve
Pressure reducing valve Capacity: 50 LPM Pressure: 420 Bar Valve suitable to the existing Eaton Vickers make.
Throttle and check valve Capacity: 50 LPM Pressure: 420 Bar suitable to the existing REXROTH make valve
1/2" BSP shutoff valve line mounting Capacity: 50 LPM Pressure: 420 Bar suitable to the existing Eaton Vickers make Valve
Reclaimer boom luffing pump VANE pump Capacity: 64 LPM Displacement 75cc Speed: 1800 rpm Pressure: 250 bar max / 315 bar peak Pressure. Make: DENESION VELIJAN or Equivalent
Reclaimer slewing pump Type: closed loop axial pistion pump Capacity: 135 LPM Displacement 75cc Speed: 1800 rpm Pressure: 250 bar max / 280 bar peak Pressure. Make: SAUER DANFOSS or Equivalent
JAI ENERGY ENGINEERS (BID ID -1353521)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .