| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.3 LAccepted-AOC | ₹23.3 L Quoted ₹23.4 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹23.8 L+₹40,050 (1.71%)Rejected-Finance 50A 7B 5C UMARPUR NIWA DHOOMANGANJ PRAYAGRAJ UP | PRAYAGRAJ | UTTAR PRADESH | 211011 | ₹23.8 L+₹40,050 (1.71%) | L2 | Rejected-Finance Being L2 |
| 3 | L3₹26.4 L+₹2.9 L (12.4%)Rejected-Finance | ₹26.4 L+₹2.9 L (12.4%) | L3 | Rejected-Finance Being L3 |
| 4 | L4₹26.6 L+₹3.1 L (13.2%)Rejected-Finance | ₹26.6 L+₹3.1 L (13.2%) | L4 | Rejected-Finance Being L4 |
| 5 | L5₹26.7 L+₹3.3 L (13.9%)Rejected-Finance | ₹26.7 L+₹3.3 L (13.9%) | L5 | Rejected-Finance Being L5 |
Tender Value
₹24.3 L
EMD Value
₹48,600
Closing Date
31 Jan 2024, 6:00 pmClosed
GARRISON ENGINEER (MIS) MHOW
Garrison Engineer (Maint) Infantry School , Mhow - 453441
SPECIAL REPAIR TO BUILDING NO SM 142 MANEKSHAW HALL AT DSOI UNDER GE MIS MHOW
2024_MES_635665_1
8618/GE(MIS)/MHOW
Open Tender
Civil Works
Item Rate
150 days
INFANTRY SCHOOL MHOW
All as per Tender document
7 documents required · 7 mandatory
₹500
Garrison Engineer (Maint) Inf School
₹48,600
Yes
26 Feb 2024
3 Jan 2024
3 Feb 2024
3 Jan 2024
31 Jan 2024
17 Jan 2024
Amount
Taking down shuters of any description not exceeding 1 sqm each and removing from site complete all as specified and as directed.
Taking down shuters of any description exceeding 1 sqm but Not exceeding 2 sqm each complete all as specified and as directed.
S & F second class hard wood plain, solid straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified
S&F 35mm thick factory made second class hard wood plain, framed pannelled shutters (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per (IS : 1003 part-I , kiln seasoned and chemically pressure treated complete all as specified
S & F 35 mm thick factory made, second class hard wood glazed and skeleton shutters open rebeated and prepared to received glass, gauzed, without sash bar edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc, size of member of shutter as per specified in SSR Part-I Section 8, clause 8.24 (a) and for door and fixed with chowkats, chemically pressure treated complete all as specified
S&F factory made Double side prelam PVC sheet door frame of size 50mm x 47mm made out of 5mm prelam PVC sheet reinforced with ms square tube, & edges will be painted to match with prelam sheet complete all as specified and as directed.
S&F factory made Double Side Prelam PVC door shutter 30mm thick (style) consisting of frame made out of ms tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and Single Side Prelam PVC sheet for top rail, lock rail & bottom rail. Panelling of Single Side Prelam PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement including Hinges for fixing and handle/tower bolt as per site requirement complete all as specified and as directed.
S & F factory made 25 mm thick 100% solid WPC (wood polymer composite) laminated flush door shutter of required size comprising of virgin PVC resin of K value 57-60 ( suspension grade), Calcium carbonate and natural fibers ( Wood powders / rice husk/wheat husk) and non toxic additives made from extension process WPC foam sheet single extruded (Inner) with having minimum density not less than 650 kg kg/cbm, an ISO 9001-2015 certified company, having good screw holding capacity (Screw withdrawal strength of 200 N (Face) & 1100 N (Edge) minimum compissive of 50N/mm2 Modulus of elasticity 850N/mm2 and resistance of spread of flame of class A category property of being Termite/ borer free, water/ moisture proof and fire retardant WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted on both faces of shutter and fixing stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws, all as per direction of Engineer-In- charge,Material test certificate and authentication should be compulsory provided by the manufacturing company, complete all as specified and as directed.
S&F factory made 100% solid WPC (Wood polymer composite) Door frame 90mm X 45mm (Moulded) single rebated made from wood polymer composite (single extruded process material comparison of virgin PVC polymer of k value 57-60 (Suspension grade), calcium carbonate and natural fibers (Wood powder/rice husk/wheat husk) and Non toxic additives fabricated with meter joints after applying PVC solvent cement & screwed with full body treaded star headed screws having minimum frame density of 750 kg/ cbm, an ISO 9001-2015 certified company, having good screw holding capacity (screw withdrawal strength of (Min 990 N ), minimum compressive strength of 58n/mm2, Modulus of elasticity 900N mm2 and resistance to spread of flame of class A category with property of being Termite/borer proof, water/ moisture proof and fire retardant & fixed with position with SS dash fasteners / Hold fast of required dia and length, all as per specifications drawings as directed by the Engineer-In-charge,Material test certificate and authentication should be compulsory provided by the manufacturing company including hold fast or fasteners, complete all as specified and as directed.
Taking down cement plaster on brick or concrete surfaces, parapets including raking out joint, hacking for key, scrubbing down with water etc complete all as specified
M&L for applying two coats of 1st Quality oil emulsion distemper over a coat of primer over two coats of Acrylic/WaterProofing Wall Putty on walls complete all as specified and directed. Note:- Putty shall be measured and paid separately under the relevant item.
M&L for preparation of old decorated surfaces of wall including brooming , scraping down,smoke spot, moss, efflorescent salts, trading oil, greasy spots and stopping nails marks and applying two coats of 1st quality oil emulsion distemper white/coloured over 2 coats of Acrylic/WaterProofing Wall Putty (wherever required in patches) all as specified and directed Note:- Putty shall be measured and paid separately under relevan item.
M&L for preparation of old decorated surfaces of wall including brooming , scraping down, smoke spot, moss, efflorescent salts, trading oil, greasy spots and stopping nails marks and applying one coat of 1st quality oil emulsion distemper all as specified and directed.
M&L for applying two coats of Acrylic Smooth exterior paint of required shade @ 1.67 litre /10 sqm over and including a coat of primer @ 2.20 kg /10 sqm of same make base over a coat of Acrylic / water proofing wall putty all as specified Make: Asian - Apex or other equivalent as approved by GE
M&L for preparation of old decorated surface of wall including brooming , scraping down smoke spot, moss, efflorescent salts, trading oil, greasy spots and stopping nails marks and applying two coats of exterior weather proof water base emulsion paint white / coloured over a coat of primer of same make over white cement based putty (where ever required in site in patches) all as specified .Note: Putty shall be measured and paid seperately under relevant item . Make: Asian - Apex or other equivalent as approved by GE
M&L for preparation of newly plastered surface of wall and and applying 2mm thick Acrylic / water proofing wall putty in two coats (each coat not less than 1mm thick ) and surface finished even and smooth with sand paper complete all as specified
Demolition of brick work built in cement mortar of any description including all quions ,arcches , pillars etc complete all as specified
M&L for brick work in cement mortar 1:6 using sub class `B ` modular brick straight or curved on plan exceeding 6.0m mean radius complete all as specified
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick or concrete surface of wall and finished even and smooth without using extra cement complete all as specified
M&L for rendering 10 mm thick in cement mortar 1:6 on fair faces of wall / concrete surfaces finished even and fair complete all as specified
Preparation of old painted surfaces of wood/wood based materials exc 10cm width or girth and applying one coat of synthetic enamel paint as directed and specified.
Demolition of cement concrete in ground floor and paving not exceeding 15cm thick ( below or above ground level ) complete including removal of debries out side MD land all as specified and as directed .
M&L for plain cement concrete 1:2:4 type B0 using 12.5 mm graded crushed stone aggregate as in sub base, levelling course, etc complete all as specified
M&L for PCC1:4:8 type D2 using 40mm graded stone aggregate as in sub base of floor, etc complete all as specified
Dismantling of floor, hearth , or wall tiling including cement mortar bedding ( but not backing ) and rubbish off the primeses complete all as specified
M&L for scratch free Glazed (Porcelain) Vitrified Tiles (GVT)/ Polished Glazed Vitrified Tiles (PGVT) 9mm to 10mm thick (square or rectangular) area of each tile exceeding 0.36 sqm but not exceeding 0.72 sqm ( ie) size 600x1200 in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match with colour of tile over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and as directed. Make of tile : Superior quality tiles from Kajaria/Somany/Orient Tiles. Note : (a) Size and pattern / texture of GVT (Matt Finish) / PGVT(Glossy Finish) shall be approved by GE (b)Glazed Coating on GVT / PGVTshall not be less than 1mm thick .
All as per item No 26 above but as in skirting/ dado etc with and including 10mm thik backing coat in cement mortar 1:4 on wall complete all as specified
M&L for scratch free Glazed (Porcelain) Vitrified Tiles(GVT) /Polished Glazed Vitrified Tiles (PGVT) 9mm to 10mm thick (square or rectangular) area of each tile exceeding 0.18sqm but not exceeding 0.36 sqm (ie) of size 600x600mm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match with colour of tile over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified Make of tile : Superior quality tiles from Kajaria/Somany/Orient Tiles. Note : (a) Size and pattern / texture of GVT (Matt Finish) / PGVT(Glossy Finish) shall be approved by GE (b)Glazed Coating on GVT / PGVTshall not be less than 1mm thick .
All as per item No 28 above but as in skirting/ dado etc with and including 10mm thik backing coat in cement mortar 1:4 on wall complete all as specified
M&L for glazed ceramic coloured tiles (Matte /Gloss Finish) of size not less than 450x300x7 mm thick on vertical surfaces such as wall ,dado,skirting etc set and jointed in neat cement slurry and pointed with coloured cement to match with colour of tile over and including 15 mm thick backing coat on fair faces of brick work in CM 1:4 complete all as specified Make of tile:- Superior quality tile from Kajaria/Somany/Orient tiles. Note:Pattern/Texture and finish of wall tile shall be approved by GE
M&L for glazed ceramic coloured tiles (Matte/Gloss Finish) of size not less than 300x600x7 mm thick on vertical surfaces such as wall,dado,skirting etc set and jointed in neat cement slurry and pointed with coloured cement to match with colour of tile over and including 15 mm thick backing coat on fair faces of brick work in CM 1:4 complete all as specified Make of tile:- Superior quality tile from Kajaria/Somany/Orient tiles. Note:Pattern/Texture and finish of wall tile shall be approved by GE
M&L for non skid ceramic coloured tiles 7mm to 8mm thick (square/rectangular) of size 300x300mm / 400x400mm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with colour of tile including 15mm thick screed bed or bedding layer in cement mortar 1: 6 complete all as specified Make of tile:- Superior quality tile from Kajaria/Somany/Orient tiles. Note:Pattern/Texture and finish of wall tile shall be approved by GE
Demolition of Stone slabs and tiles of any description or thickness in floors complete all as specified .
M&L for machine cut kota stone slab in flooring 20mm to 25mm thick laid over and including 15mm thick screed bed in cement mortar 1:6 and pointed with cement mixed with pigment to match with the shade of slab including rubbing and polishing complete all as specified
M&L for 18mm to 20 mm thick Granite slab work (table rubbed and polish) of approved quality of required size in floor,wall,cooking platform and like bedded and jointed in grey cement slurry and pointed with coloured cement (1:2) usig marble dust with admixture of pigment to match the shade of granite stone laid over and including 20 mm thick screed bed in cement mortar 1:4 including polishing by using mechanical grinder complete all as specified and directed. Note : Size of Granite slab shall be maximum as available at market /as per site requirement and shall be approved by GE
M&L for 60mm thick machine pressed rubber moulded precast cement concrete interlocking paver block (glossy finish) of M-35 Gde of approved shape, size and colour conferming to IS 15658-2006 and including joints filled with sand and stone dust 50mm thick as in levelling course of interlocking complete all as specified
M&L for chequered cement concrete tiles with grey cement and pigment of size 30cmX30cmX30mm thick ,set and jointed and pointed in neat cement slurry in floor etc over and including 15mm thick screed bed in CM 1:6 complete all as specified
M&L for precast cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in kerb stone / kerb block ,machine pressed ,bul lnosed shape at top as directed and finished the surface even and smooth including necessary form work /moulding ,fixing, jointing kerb block in cement mortar (1:4) complete all as specified
M&L for providing precast cement concrete louvers and jallies 50mm thick (measured solid) with cement concrete 1:2:4 type B0 using 12.5mm graded stone aggregate, set in cement mortar (1:4) including all moldings but excluding frame complete all as specified and as directed.
M&L for preparation of old decorated surfaces of wall by removing existing putty/distemper complete and applying two coats of sureseal of Dr Fixit or other equivalent as approved by GE and subsequently applying two coats of Oil Emulsion Distemper over a coat of 2 mm Acrylic/WaterProofing Wall Putty(each Coat not less than 2mm) complete all as specified and directed. Note: (a) First coat of sureseal (no dilution) shall be applied and allow it to dry for 6-8 hours. (b) Second coat of sureseal (no dilution) shall be applied, Perpendicular to first coat direction and allow it to dry for 6-8 hours. (c) Application of sureseal treatment shall be executed through expert team of Manufacturer or through authorised applicator of Manufacturer. (d) Putty and Oil emulsion distemper shall be measured and paid Seperately under relevant item
M&L for repairing of walls and other vertical surfaces with and including comprising of the following specifications:- (a) Cleaning and drying thoroughly the existing surface of walls for all foreign matters such as fungus, moss, dust etc by wire brushing and removing the existing plaster surface (b) Applying first coat of Dr Fixit Rain coat Neo or other equivalent (Ready mixed by manufacturer in sealed container ) and mix the content well before the application with brush / roller on the vertical surface in SSD condition all as per Manufacturers instruction (By diluting 1 Litre of redi mix mixed with 100 ml of clean portable water and cover the area at the rate of 3 to 4 sqm/litre (c). Applying second coat of Dr Fixit raincoat Neo or other equivalent without dilution as a water proof top coat with roller / brush as directed and cover the area at the rate of 3 to 4 sqm/litre and all as per Manufacturer instruction Note: Application of Dr Fixit Rain coat treatment shall be executed through expert team of Manufacturer or through authorised applicator of Manufacturer.
M&L for Water proofing treatment on "Non approachable / non accessible roof/Chhajja" surface (Horizontal & Vertical surfaces) upto a height of 25m wiyh the following specification through the authorized applicator of the Manufacturer including removal of existing treatment of any description complete all as specified and directed. (a) Preparation of surface by opening the cracks/removal of loose concerete all as specified and directed. (b) Washing the entire roof/Chhajja surfaces by using compressor to remove dirt, dust,algae fungi or other contaminants from joints and entire surface. (c) Applying Dr Fixt crack X or other equivalent as approved if crack is upto 5mm and use Dr. Fixit Crack X Shrink free in case of wider cracks (d) Priming coat of Dr fixit URP with fiber mesh (e) Applying two coats of Dr. Fixit Roof seal at 0.75 liters per sqm / coat, at an interval of 12 hours between the coats and allow drying completely. Note: (i) Work shall be carried out through any one of the following authorised applicator of the product. (A) P Tech Solutions 92 Anurag Nagar Ring Road Indore (B) MR clean Ventures E-4,402 Arera Colony Bhopal 462016 (C) Property care, 244 D scheme No 71 Near Shriji Vatika indore (ii) Cost of formwork /scaffolding shall deemed to be included in the quoted rate
S&F Powder coated aluminium sliding glazed windows with three track shutter sliding (two shutters with glazed /Glass and one shutter with wire mesh) with following specification complete all as specified and as directed by Engineer-in-charge. (i) Windows frame of cross section 101mm x 44mm (ii) Three way track for sliding shutters of cross section 91.8mm x 31.75mm (iii) Sliding shutter frame of cross section 40mm x 18mm (iv) 4 mm thick glass superior quality. (Min) (v) IDPE Rubber guasket for fixing of glass. (vi) Locking cleats per shutter -01 No. (Min) (vii) Sliding rollers per shutter - 02 Nos. (Min) (viii) Stainless steel wire cloth 0.30mm nominal dia of wire and average width of aperture 1.40mm for shutter- 01 No. Note:(a)Thickness of Aluminium Section should be 2 to 3mm. Over all thickness and Cross Section of Aluminium section if any increase in above specification shall be approved by Engineer in Charge as per Site requirement without any extra cost. (b) Size / drawing of Window shutter shall be provided by Engineer in Charge during execution as per site requirement.
S&F powder coated aluminum door with the following specification and making good the disturbed surfaces as per existing finishes complete all as specified and as directed. (a) Cross section of chowkhat frame 101.60 mm x 44.45mm (b) Cross section of hanging and meeting style 83 mm x 44mm (c) Top rail of cross section 114 mm x 44 mm (d) Bottom rail of cross section 114 mm x 44 mm (e) Locking rail (middle rail) of cross section 83 mm x 44 mm (f) 4 mm thick glass superior quality. (Min) (g) Aluminum handle eisc type -02 Nos per shutter (inside & out side). (h) Aluminum door stopper heavy duty-01 No per shutter. (i) Aluminum tower bolt 200mm long-01 No per shutter (inside). (j) Concealed Lock with key superior quality makae and type as approved by GE openable both from inside & out side -01 No per shutter. Note :- (1)Thickness of Aluminium Section should be 2 to 3mm. Over all thickness and Cross Section of Aluminium section if any increase in above specification shall be approved by Engineer in Charge as per Site requirement without any extra cost. (b) Size / drawing of door shutter shall be provided by Engineer in Charge during execution as per site requirement.
M&L for 25mm thick plain cement concrete1:2:4, type B1, using 20 mm aggregate as in roof padding etc complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:4 on roof surface including mixed with WPC as per manufacturer's instruction's and finishing the surfaces even and smooth without using extra cement complete all as specified
M&L for providing water proofing roof treatment with polymeric standard water proofing membrane, Aqua flex manufactured by M/s Bengal Bitumen, MULTIPLAS STANDARD, manufactured by STP TEXAS Ltd / Hyperplas manufactured by IWL Ltd with 10 years guarantee for water tightness complete all as specified as under and all as per Manufacture's instruction :- (a) Preparation of RCC roof surface and applying one coat of polymeric modified bitumen 85/25 grade @ 1.2Kg/Sqm over a coat of polymeric primer @ 0.30 Kg/sqm including cleaning surface all as per manufacturer's specification complete all as specified and directed. (b) Supply & laying water proofing APP polymeric membrane 3mm thick and 3Kg/Sqm HYPERPLAS STANDARD/ MULTIPLAS STANDARD consisting of 100 micron HMHDPE film centre core including coating the surface with compatible primer and torch application of membrane with 10cm overlaps as required thereof, complete all as specified and directed (C) Applying one coat of polymeric modified bitumen 85/25 grade @ 1.2Kg/Sqm over APP membrane (d) Applying two coats of Aluminium bituminous paint @ 0.15 Kg/Sqm over the APP membrane surface. NOTE:- Application of water proofing treatment shall be executed through expert team of manufacturers or their authorised applicator
S&F 0.50mm thick (including coated thickness) pre-colour pre- profiled (Galvalume/zinkalume) sheets of required colour and design having tensile strength of 550 Mpa as in roof sheeting / sunshade/ wall cladding, north light curves, fixed with zinc coated self drilling fastener including EPDM washer complete laid with one corrugation side laps and min 150mm end lap laid to slope all as per manufacturer / profile maker instruction complete all as specified and as directed.
S&F mild steel hollow ,Joist, channel, angle, tee or tubular Section work in tubular trusses, purlins, rafter, tubular column, where connected common rafter and running rails fixed with angle cleat or other connection plates including special shaped washer etc, complete using ERW or induction butt welded tubes conforming IS-4963,1993 and IS-1161-1979 grade ST-240 complete all as specified .
S&F Mild steel framed work as in doors or gates of angle iron, door frame or other section with gusset plate, rails, braces etc complete, drilled for fixing of steel sheeting or other covering etc, to prepared for hanging or sliding with including either hooks and hinges also fastening grills, grating, hold fast of doors and windows chowkat etc, with ends of bars shouldered and or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework of water tanksand fixing and similar work confirming to Fe 290 Gde E-165 including dismantling of existing timber frame structure if any complete all as specified and as directed.
S&F Mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified
S&F PVC prelam sheet wall/ceiling paneling of thickness 5mm consisting of panels having size 1.22 M x 2.44 M stuck on inner frame work of 50 mm wide strips of 5mm thick prelam PVC sheet of 600 Kg/cbm density manufactured by an ISO-9000 certified company. The strips should have in their centre a groove of 6mm width and 1mm depth of sinking the head of the screw used to fix the strip to the wall vertically at an equal interval of 10” between two PVC strip. The PVC strip shall be fixed to the wall using 65mm long M.S screws through the groove in the strip by using PVC fastners. The distance between two screws shall not be more than 200mm. A groove of 2mm may be left at the joints of two panel for aesthetic looks. The exact size of the panel and correspondingly of grid may vary depending on the size of wall. Optionally a strip of 5mm thick PVC sheet of width 75mm feathered at edges shall be struck at the places where two panels are jointed, using solvent including dismantling of old wooden boarding complete all as specified and as directed
S&F Gypsum Board 12mm thick Seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre on GI frame work for seamless ceiling comprising of GI perimeter chennel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylone sleeves and screws at 450mm centre to centre/ intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm susoended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exceeding 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with clips of 10.5mm fixed to the intermediate channel at 457mm centre to centre inluding finishing the joint of face board with specially formulatted jointing compound and 48 mm wide fibre tape to provide seamless finish Ceiling shall be sealed at joints and finished with jointing compound etc complete including finishing the exposed surfaces of false ceiling with two coats of plastic emulsion paint over a coat of primer complete all as specified and directed.
S&F PVC Ceiling Lining (False Ceiling) consisting of 5mm thick Plain colour PVC sheet 8 to 10 mm hollow section inclusive of solvent cement and fixing at site on frame work as per requirement on site complete all as specified
S&F fabricating coloured powder coated aluminium frame work,door shutter ,windows , ventilators, partitions with one or more rebates sections of approved tint as required for partitions including beading,cleat, screws,fasteners, plugs, for fixing with wall/ceiling columns/beams etc complete all as specified
S&F aluminium coloured power coated partition,window , ventilator shutters, sliding type without sash bar aluminium section weighing 0.55 kg/m including necessary locking arrangement, guide wheels, joining cleats, glazing clips rubber packing anodised aluminium snap beading screws complete all as specified and directed.
S&F 4.8 mm thick plain or tinted glass, ordinary quality including rubber gasket for packing and fixed to aluminium doors /window /partition including necessary cutting / moulding and chamferring of edges for service window /counters complete all as specified .
S&F galvanised Stainless steel wire cloth of 0.36mm dia wire and average width of aperture 1.4mm & fixed with tacks of stainless steel wire staples etc complete all as specified
S&F PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet 8 to 10 mm hollow section inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing, including taking down of old board, complete all as specified
S&F Veneered decorative 18 mm plywood, grade 1 (with BWR resin) with decorative laminate min 1mm thick on both faces, fixed with screws to timber frame work as in cupboard shelf/partition including taking down the existing structure / board on site all as specified . Note : Colour and texture of laminate shall be approved by GE
S&F factory made PVC shelf / partition of required size consisting of panel of 18 mm thick required size consisting of panel of 18 mm thick celuka PVC ply and for supporting the hold of shelf / partition and shall provided 3 edges in size 18mm x 18 mm as per required length the front side of the edge visible in the front of the shelf/partition to be edge lipped by 18mm width x 1 mm thick PVC sheet of density 600 kg/cum manufactured by ISO 9001-2015 Certified Company , using solvent cement etc. complete all as specified and directed by Engineer-in-charge.
S&F 12mm thick Frosted Toughned Glass fixed on patch hinges/pivot for smooth functioning in door shutter including stainless steel handle of 8 inches long and mortice locking arrangement complete all as specified and as directed
S& F in repair Rotational moulded Polyethylene water storage tank 1000 litres capacity (cylidrical vertical with closed top) three layered hoisted and fixed in position all as specified in SSR part I complete all as specified
S& F in repair Rotational moulded Polyethylene water storage tank 500 litres capacity (cylidrical vertical with closed top) three layered hoisted and fixed in position all as specified in SSR part I complete all as specified
S&F in repair 15mm bore steel tubing medium grade ,galvanized with all fitting such as bend ,elbow, socket,tees,and fixed complete to wall or in ceiling or in floors including cutting threading and making forged bends on pipes MS hooks etc ,complete all as specified and as directed.
All as per item no 66 above but 20mm bore
S&F in repair vitreous china wash basin white (table top) of size 520x360x125 mm including 32mm brass CP waste coupling complete all as specified and as directed . Make:Jaquar Cat Part No.- FLS-WHT-5931 or other equivalent as approved by GE
S&F in repair Vitreous China Urinal, Half stall type,white with grating and union for discharge pipe, urinal spreader including all fixing accessories, with waste pipe complete all as specified and as directed Size of Urinal: 355x340x535 mm Make : Jaquar Cat Part No. URS-WHT-13261H or other equivalent as approved by GE
S&F vitreous china wall hung European wash down water closet pedestal pattern (S trap) of size 370x540x410 mm white with PP Soft Close Seat Cover, hinges and all accessories icluding concealed flushing cistern & Chromium Plated Control Plate complete all as specified and as directed . Make :Jaquar Cat Part No:JCP-CHR-372415 and flush pipes Make: Jaquar Cat Part No: CNS-WHT-959SPP or other equivalent as approved by GE
S&F health faucet with flexible pipe of one metre length including wall hook for EWC complete all as specified.Make:Plumber/Essco of jaguar (Economical Range)
S&F in repair PVC valveless,syphonic action type flushing cistern, 10 litres capacity ,low level ,white with inlet ball valve,float and handle including brackets and connection to pipe and fixing of chain and pull or lever if any complete all as specified and directed.Make : Parryware/Plumber/Essco of jaguar (Economical Range)
S&F in repair CP 15 mm dia Tall Body Pillar Tap for wash basin , centre hole, mixing hot & cold water, fancy type, cast copper alloy, chromimum plated with capstan head, chromium plated, screwed down high pressure, screwed for iron pipe etc complete all as specfied and directed Make: Parryware Cat Part No: T1346A1 or other equivalent as approved by GE
M&L for Aluminium Composite Panels (ACP) any colour of exterior edge for cladding near entrance of external wall /column/canopy cladding in combination of solid/Metallic colours, including all necessary frame work and complete weather sealing. The composite panel should consist of 3mm thermoplastic core of LDPE sandwiched between 2 skins of 0.5mm thick aluminium sheet (alloy designation 310S) making a total panel thickness of 4mm. The surface will be furnished with Lumiflon based flourcarbon coating on top sides and service coating on reverse side. Coatings shall conform to specifications of ECCA/AAMA and conforming to the mechanical properties of panel as per detailed technical specifications. The system shall be fixed using GI brackets and stainless steel bolts and nuts complete with spring washers and cap nuts and all other necessary accessories. The bracket support shall be designed as per manufactures specification and shall withstand a wind pressure of 150 Kg/Sqm. All hardware shall corrosion resistant frame out of anodised aluminium member. Make: Alucobond/Alstrong or other equivalent make as approved by GE
M&L for writting letters or figures (Block, Roman, Italic or Indian) with stainless steel 304 gradde, thickness of steel sheet 2/3 mm thick projected type,each letters not exceeding 50mm depth , not exceeding 40cm high and not exceeding 30cm width , fixed at site over granite/stone/wall/plate/ACP or any other surfaces including necessary fixing arrangements like adhesive/stainless steel screw, etc complete all as specified and as directed by Engineer-in-Charge.
S&F stainless steel railing includng all fixing arrangement complete all as specified and directed.
M&L for grinding the existing Kota stone flooring ,steps etc with wax polishing mixed with pigment to match with shade of kota slab complete all as specified and directed.
S&F 10mm thick High Performance Polycarbonate Hollow sheet containing 3 wall / Multiwall rectangular Structure of clear tint as approved by GE as in roof dome structure /similar nature building for Skylight Roof in buildings upto 20m height fixed with rubber neoprene /other packing material fixed and packed with sheet (Gap Between sheet shall be sealed with silica gel) including necessary scaffolding and fixing arrangement and removing of existing sheet of any description complete all as specified and as directed. Note : (a) Polycarbonate Sheet should have a layer of UV absorber (co-extruded onto the surface of the sheet) forming a barrier against UV radiation. (b) .Weight of Polycarbonate sheet shall not be less than 2.5Kg/sqm and Minimum Tensile Strength must be 60Mpa. (c) Size shall be approved by Engineer-in-Charge as per site requirement ,accordingly procured from Manufacturer . (d) Texture/Colour of Polycarbonate sheet shall be approved by GE. (e) Polycarbonate Sheet shall be fixed with water proof tapping screws at distance as directed and gap sealed with neutral silicone material.
Taking down the existing Urinal / Urinal Sensor machanisum and repairing its parts such as battery,sensor part, wiring etc and including spares as required for functioning of urinal and refixing the Urinal / Urinal sensor in the same place complete all as specified and directed by Engineer-in-charge. Make of spare parts :- Jaquar,CERA,Hindware and Parryware
S&F in repair PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints laid on wall / floor complete all as specified
S&F in repair PVC ( SWR) bends any radius bore of 100 mm all as specified
S&F in repairs salt glazed stoneware drain pipe of 150mm internal dia laid in trenches and jointed in cement mortar (1:1) complete all as specified .
M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate as in concrete bed to drain pipe including packing under and haunching against the sides of pipe after they are laid and tested internal dia of pipe 150mm complete all as specified
M&L for RCC type 1:2:4 type B1 using 20 mm graded granite stone aggregate) as in precast cover slab for manholes and soak well cover slab etc set in cement mortar (1:4) etc with and including necessary form work all as specified . Note:- Reinforcement shall be measured & paid separately under relevant item.
M&L for high strength steel deformed TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally and binding with and including mild steel wire (annealed) not less than 0.90 mm dia, etc complete all as specified and directed.
M&L for plain cement concrete 1:3:6 type C2 using 40 mm graded stone aggregate as in foundations, filling and mass-concrete complete all as specified
Excavation in trenches by mechanical means (by using Hydraulic Excavator) not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or for shafts, wells, cespits, manholes pier hold etc getting out in hard / dense soil /Bitumenous Road complete all as specified and directed.
Excavating over areas by mechanical means( by using Hydraulic Excavator) not exceeding 1.5 m deep and getting out in hard / dense soil complete all as specified and directed.
Removing excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified
Returning, filling in, soil including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete.
ss construction
Chitragupta Construction
sunrise enterprises
M/S Sunshine Construction
kriti construction
sunway associates
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .