Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-AOC 0 PRAGATIPUR DHARMA SARMA PATH BIRUBARI KAMRUP ASSAM 781016 | KAMRUP METRO | ASSAM | 781016 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹26.1 L+₹4.2 L (19.1%)Rejected-Finance GOSWAMI COLONY PO UDAYAN VIHAR DISTT KAMRUP ASSAM 781171 | KAMRUP METRO | ASSAM | 781171 | L2 | Rejected-Finance Not Validated (Other than lowest bidder) | |
| 3 | L3₹27.8 L+₹5.9 L (27.0%)Rejected-Finance HOUSE NO 29 A SIJUBARI NIZARA PATH PO PS HATTIGAON GUWAHATI 38 | KAMRUP METRO | ASSAM | 781038 | L3 | Rejected-Finance Not Validated (Other than lowest bidder) | |
| 4 | L4₹27.9 L+₹5.9 L (27.1%)Rejected-Finance MES COLONY KUMBHIGRAM AIRPORT CACHAR ASSAM 788109 | KUMBHIGRAM | CACHAR | ASSAM | 788109 | L4 | Rejected-Finance Not Validated (Other than lowest bidder) | |
| 5 | L5₹29.8 L+₹7.8 L (35.8%)Rejected-Finance OIL INDIA LTD GATE NO 02 PO UDAYAN VIHAR GUWAHATI ASSAM | KAMRUP METRO | ASSAM | 781001 | L5 | Rejected-Finance Not Validated (Other than lowest bidder) |
Tender Value
Refer Docs
EMD Value
₹56,000
Closing Date
20 Mar 2023, 6:00 pmClosed
GE GUWAHATI
GE GUWAHATI, PO SATGAON, DISTT KAMRUP - 781027
REPAIR/REPLACEMENT OF LIGHTING PROTECTION EARTHING AND CONNECTED ITEMS OF OTM/MD ACCN AT BASISTHA AND OTHER THAN BASISTHA AREA UNDER GE GUWAHATI
2023_MES_581004_1
GE/GUW/82/8305 OF 2022-23
Open Tender
Civil Works
Item Rate
150 days
GUWAHATI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE GUWAHATI
₹56,000
Yes
11 May 2023
14 Feb 2023
23 Mar 2023
14 Feb 2023
20 Mar 2023
28 Feb 2023
14 Feb 2023 - 21 Feb 2023
Amount
Dismantling/taking out unserviceable eathings of any description with all acessories and removing debries from the site complete all as directed.
M&L Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to GI Earth Strip 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia TMT bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 40 mm bore (light grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion complete all as specified and directed.
M&L Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to GI Earth Strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia TMT bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 40 mm bore (light grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion complete all as specified and directed.
M&L Earthing complete with Copper Earth earth plate electrode 600 mm x 600 mm x 3 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to Copper Earth Strip 20x3mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia TMT bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth strip protected by 25 mm bore (light grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion complete all as specified and directed.
M&L Earthing complete with Copper Earth earth plate electrode 900 mm x 900 mm x 5 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to Copper Earth Strip 50x6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia TMT bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth strip protected by 75 mm bore (light grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion complete all as specified and directed.
Taking down of unserviceable earthing strip/earth wire of any description and from any position complete all as directed
M&L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20x3mm copper strip complete all as specified and as directed.
All as per item No. 7 here-in-above but fixing only Note: Serviceable copper strip earthing obtained from item No 6 here-in-before
M&L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm galvanised iron strip complete all as specified and as directed.
M&L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x3mm aluminium strip complete all as specified and as directed.
All as per item No. 10 here-in-above but fixing only Note: Serviceable Aluminum earthing strip obtained from item No 6 here-in-before
M&L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wirecomplete all as specified and as directed.
All as per item No. 12 here-in-above but fixing only Note: Serviceable Galvanised iron earthing wire obtained from item No 6 here-in-before
M&L in repair, 32mm bore GI pipe light grade with all necessary fittings (ISI marked) as in protection to earting conductor protection fixed to pole, with necessary clamps, nuts, bolts etc laid in trenches/road/floorfixed in wall with saddles as directed complete all as specified and as directed.
M&L in repair, 40mm bore GI pipe light grade with all necessary fittings (ISI marked) as in protection to earting conductor protection fixed to pole, with necessary clamps, nuts, bolts etc laid in trenches/road/floorfixed in wall with saddles as directed complete all as specified and as directed.
M&L in repair, 20mm bore GI pipe light grade with all necessary fittings (ISI marked) as in protection to earting conductor protection fixed to pole, with necessary clamps, nuts, bolts etc laid in trenches/road/floorfixed in wall with saddles as directed complete all as specified and as directed.
M&L in repair, Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw omplete all as specified and as directed.
M&L in repair, Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and as directed.
Cutting existing 40/50mm bore steel tubing for alterations or additions (Each cut measured) complete all as directed.
Screwing existing 40/50mm bore steel tubing for alterations or additions (or lengthening screw on pipe to form connector) complete all as directed.
M&L checking of existing GI earthing pits by earth meager, entering the initial values of eathing and lighting conductors and repair/replacement of lightening conductors, repair/replacement of GI strips where required and repair to earthing pits and testing of earth resistance value and providing salt, charcoal, replacement of earthing plate as required and entering the final values in register complete all as directed. Note:- (i) GI strip, Earthing plate Salt and Charcoal shall be measured and paid seperately at Supply only rates under appropiate item (ii) Unit rate quoted is deemed to be inclusive of labour cost to make the eathing pit in serviceable condition. (iii) Earth meager test report shall be inverably submitted along with every BILL (S), (intial & final), type of repair in each earth pit required, such as replacement of conductor, earth plate, etc as required dully signed by Contractor, Engg-In-Charge and GE
M&L checking of existing COPPER earthing pits by earth meager, entering the initial values of eathing and lighting conductors and repair/replacement of lightening conductors, repair/replacement of GI strips where required and repair to earthing pits and testing of earth resistance value and providing salt, charcoal, replacement of earthing plate as required and entering the final values in register complete all as directed. Note:- (i) GI strip, Earthing plate Salt and Charcoal shall be measured and paid seperately at Supply only rates under appropiate item (ii) Unit rate quoted is deemed to be inclusive of labour cost to make the eathing pit in serviceable condition. (iii) Earth meager test report shall be inverably submitted along with every BILL (S), (intial & final), type of repair in each earth pit required, such as replacement of conductor, earth plate, etc as required dully signed by Contractor, Engg-In-Charge and GE
Supply only common salt (commercial) complete all as directed
Supply only charcoal/cabon breeze complete all as directed
Supply only Galvanized stee Earth plate 600 mm x 600 mm x 6 mm complete all as directed
Supply only Copper Earth earth plate 600 mm x 600 mm x 3 mm complete all as directed
Supply only Funnel with mesh for eath pit complete all as directed
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for column & wall foundation, UG Cable and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n exc 25 cm layers in soft/loose soil complete all as specified and directed.
Removing excavated material (Soil) not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified and directed.
Cleaning of MES water supply installation/campus by surface dressing, trimming of natural ground to removing all vegetations/shurbs/bushes etc , cleaning of drains and removing of rubishes/debries of the permises complete all directed. Note:- Cleaning of MES installation/campus as described may be carried out at an interval of 75 days as directed by Engg-In-Charge
M&L earth pit with PCC (1:3:6) type C-I (20mm graded stone aggregate) complete all as specified and directed.
M&L 50mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab reinforced with 8 mm dia TMT bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar complete all as specified and directed.
M&L Earth pit indicator for existing earthing pit made out of MS plate size 30cm x 30cm x 3mm fixed with 16mm MS square bar, 60cm long, preperation of surfaces and applying two coats of syntheic enamel (tint as directed) over a coat of red oxide zinc chrome primer and legs embedded in PCC 1:4:8 Type C2 (40mm graded stone aggregate) ( PCC block of sie 30cm x 30cm x 30cm), including writing letters, necessary earthork etc, complete all as directed. Note:- (i) Cost of writting letters is deemed to be inclusive in the Unit rate quoted and undermentioned to be written in pit indicator:-. (a) Type of earthing i.e, Chemical/copper/GI plate earthing along with type of conductor Copper/Aluminum/GI/GI wire (b) Location (c) Pit No (d) Result (e) Date of Testing (ii) Earth pit indicator shall be provided near the Earthing
S&F factory made Poly propylene earthing pit cover made out of High grade heavy duty polythene, HD PVC chamber of outer size 300mm x 300mm, with safe working load 2000Kg including dismantling existing unserviceable earth pit cover complete all as directed.
M&L copper brazing of two copper strip of size 20mm x 3mm thick to 32mm x 6mm thick/copper rod of 17mm dia and fixed on walls with post insulators /fixed on ploe with MS clamps, nits bolts, washers and post insulators complete all as directed.
S&F in repair, Porcelain Post insulators for earthing strip complete all as specified and directed.
S&F 15mm bore GI pipe medium grade water tube with all fittings laid in floors fixed to walls and ceilings or laid in floors, including necessary taking down of exsisting old pipe complete all as specified and as directed.
S&F in repair, 15mm boreGun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
S&F Rotational moulded polyethylene water storage tank (Cylindrical vertical with closed top) (confoirming to IS 12701-1996) multi layer hoisted and fixed in position 500 ltrs capacity complete all as specified in SSR Part I, including necessary dismantling old unserviceablle tank complete all as specified and as directed
M.G. ENTERPRISE
M/S SEWAK SINGH
Goswami Traders
S. R. TRADING
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .