| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 LAccepted-AOC 159 GREEN VALLEY APARTMENT DHAKOLI ZIRAKPUR MOHALI | ₹5.9 L | L1 | Accepted-AOC L1 |
| 2 | L2₹5.9 LRejected-Finance 102 STREET NO 10 1 SHAKIT NAGAR DERABASSI SAS NAGAR | S A S NAGAR | PUNJAB | 140103 | ₹5.9 L | L2 | Rejected-Finance L2 |
| 3 | L3₹6.7 LRejected-Finance | ₹6.7 L | L3 | Rejected-Finance L3 |
Tender Value
₹9.4 L
EMD Value
₹18,802
Closing Date
26 Feb 2026, 11:00 amClosed
Executive Engineer SWM MC Chd
Room No. 612 6th floor MC Building Sector 17 Chandigarh
Repair and Strengthening of existing SWD System at various locations of Sector 34, 35, 43 ,44, 49, 50, 51, 52, 61 and 63 falls under the jurisdiction of SDE MCPH Sub Division 18 Chandigarh
2026_MCC_90736_1
MCC/EE/SWM/2026/6
Open Tender
Civil Works
90 days
Chandigarh
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
₹18,802
12 Mar 2026
19 Feb 2026
26 Feb 2026
19 Feb 2026
26 Feb 2026
19 Feb 2026
Earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1:5 m in width or 10 sqm or plan) including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soils. (DSR 2.8.1)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering – All work up to plinth level: 1:5:10 (1 cement : 5 manufactured sand derived from recycled concrete Aggregate (RCA): 10 graded stone aggregate 40 mm nominal size (DSR 4.1.10A)
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : (DSR 19.6)
300 mm dia. R.C.C. pipe (DSR 19.6.4)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR 6.1.1)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 Cement : 2 coarse sand i/c manufactured sand derived from Recycled concrete Aggregate (RCA) upto 25% : 4 graded stone aggregate 40 mm nominal size Recycled concrete Aggregate (RCA) upto 25%). (NSI based on DSR 4.1.4)
12 mm cement plaster finished with a floating coat of neat cement of mix 1:4 (1cement: 4 fine sand) (DSR 13.7.2)
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform. (DSR 5.9.3)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more (DSR 5.22.6)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering , finishing and reinforcement with 1:1.5:3 (1 cement: 2 coarse sand : 3 graded stone aggregate 20 mm nominal size) (DSR 5.3)
Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality H D - 20 Circular shape 560 mm internal diameter (DSR 19.19.3.1)
Providing and Fixing of precast RCC M-20 HD Road Gully cover and frames in 1:2 Cement Sand Mortar on the top of brick masonary chamber complete in all respects to the entire satisfaction of EIC. (Size : cover 690 x 537 x 80mm ; frame : 810 x 657 x 130mm) (NSI)
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after ixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design (DSR 19.16)
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 350 to 450 mm diameter (DSR 19.21.3)
Plugging and diversion of sewer/SWD line to carry out the repair in safe manner including the cost of sand bags, wooden planks, ballies etc., complete in all respect (NSI)
Extra cutting through metalled road and their foundation including sorting screening and stacking at the site complete in all respects. (NSI )
Supplying and filling sand (recycled sand) under road crossing including carriage etc., complete in all respects to the entire satisfaction of the EIC. (NSI based on DSR 2.27)
Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge (DSR 16.83)
Dismantling of paver blocks including base of cement concrete 1:5:10 and disposal of malba as directed by EIC and therafter re-ficing of interlocking /concrete/ rubbish etc. Over 100mm thick base of coarse sand complete in all respects to the entire satisfaction of EIC.(NSI)
Carriage of Material by Mechanical Transport including loading, unloading and stacking Earth up to 3 km (DSR 1.1.2)
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m (DSR No. 2.25)
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar (DSR 15.7.4)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.(DSR 15.3)
Recovery against Old material Bricks
Recovery against Old material TMT Bars
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 12.86 MB
BOQ_110962.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid