Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.8 LAccepted-AOC 306 SHIV BARI MARG PANCHVATI NAGAR BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹29.4 L+₹91,791 (3.22%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹34.4 L+₹5.9 L (20.7%)Rejected-AOC | L3 | Rejected-AOC L3 |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
28 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF Bhisiana
HQ CWE AF Bhisiana
REPAIR AND MAINTENANCE OF AC PLANTS OF VARIOUS TYPE CAPACITY AND AC ALONG WITH CONNECTED ITEMS AT AF STATION BHISIANA
2020_MES_399831_1
CWE(BHI)/BHI-30/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AFS Bhisiana
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE AF Bhisiana
₹70,000
Yes
5 Jan 2021
2 Dec 2020
30 Dec 2020
2 Dec 2020
28 Dec 2020
16 Dec 2020
2 Dec 2020 - 8 Dec 2020
60 days
Amount
Dismantling and taking down of insulation of wall , floor and roof complete with glass wool, vapor varier, chiken wire mesh, plaster etc. complete all as specified and as directed.
Dismantling and taking down of insulation of Chiller and hot MS Pipe complete with resin bonded glass wool, husson cloth, chicken wire mesh etc. complete all as specified and as directed.
Supply & fixing in replacement of insulation of wall, floor and roof, 50 mm thick resin bonded glass wool insulation wrapped in Hussan cloth based vapor barrier and chicken wire mesh wrapped on insulation and finally covered with plaster of pairs 10 mm thick etc complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing in replacement of insulation of chiller and hot MS pipes complete with 50 mm thick resin bonded glass wool insulation wrapped in Hussan cloth based vapor barrier and chicken wire mesh wrapped on insulation and finally covered with aluminium sheet of 0.50 mm thick etc complete all as specified and directed by Engineer-in-Charge.
Digital panel mounted ampere meter 0-60 amp with CT complete all as directed.
Servicing, cleaning, checking the entire electrical control wiring of the LT system colour coding the same, replacing the same , replecing the U/S wire , lugs, thimble, Indicator lamps (RYB), including nuts, bolts and making inter locking system functional. testing complete and making good the defects complete all as specified and directed.
Supply & fix 3 pole contractors type NC-3, MNX -18 Rating 32 Amps, 415 volts and coil voltage - 220 volts.
Supply & fix 3 pole contractors type NC-3, MNX- 12 Rating 25 Amps, 415 volts and coil voltage - 220 volts.
Supply & fix 3 pole contractors type NC-3, MNX- 9 Rating 25 Amps, 415 volts and coil voltage - 220 volts.
Supply & fix 3 pole contractors type NC-3, MNX- 22-25, Rating 32 Apms, 415 volts and coil voltage - 220 volts.
Supply & fix overload relay rating 19-32 amps, 415 volts. Type - MNX.
Supply & fix overload relay rating 0-9 amps, 415 volts, Type - MNX.
Supply & fix MCCB 4 pole 160A, 25 KA complete all as specified and directed by Engineer-in-Charge.
Supply & Fix MCCB 4 pole 200 amps 35 KA.
Supply & fix 3 pole contactors type ML-1.5, Rating 32 amps, 415 volts and coil voltage - 220 volts.
Supply & fix 3 pole contactors type ML-2, Rating 40 amps. 415 volts and coil voltage - 220 volts.
S & F MCCB 100 amps, 4 pole 25 KA complete all as specified and directed by Engineer-in-Charge.
Material and labour for repair/grinding and polishing to crank shaft of the compressor make Accel, Model SMC 2– 65, Capacity 5/ 7.5/10/17 TR to the required size as directed by Engineer-in-charge.
Material and labour for repair/grinding of blower shaft make Accel, capacity 30 TR to the required size as directed by Engineer-in-charge.
Dismantling the Blower unit Complete of AHU unit and balancing the main shaft , cleaning the entire Cooling Coil with wire brush , cleaning and making the Air fins free from dirt and blockages , checking the fan belt tension , tightening the driver and drive pulleys and replacement of Shaft bearing for Central type AC Plant including reassembling the AHU unit & testing, Commissioning complete all as specified and directed by Engineer-in-Charge.
Servicing of suction and discharge valve of SMC 4-65 including replacement of O rings with Telfon Sheet.
Material and labour for reconditioning of cooling tower fan motor set of any capacity including oiling, gresing replacement of fa blade damaged shaft,internal winding, testing compelete all as directed by Engineer-in-Charge.
Servicing the condensor water Pump set of any capacity including oiling , greasing, replacement of gland paking , tightening the bolts and nuts, testing complete all as directed by Engineer-in-Charge.
Material and labour for leak testing the complete system of Central/Package type AC Plant using nitrogen gas complete all as specified and directed by Engineer-in-Charge.
Supply & Charging Refrigerant Gas R-22/F-22 in company's sealed cylinder returnable.
Material and labour for replacement of thermometer 12 mm dia , range 0-100 degree centrigraded suitable for fixing at condesor water outlet including removing of U/S thermpmeter.
Material and labour for replacement of Overload relay for compressor starter 13.2 A to 20 A.
Material and labour for replacement of V Belt size 36.
Material and labour for replacement of V Belt size A-30.
Material and labour for replacement of V Belt size B-32.
Material and labour for replacement of V Belt size B-69.
Supply & Charging Refrigerant Gas R-407 in company's sealed cylinder returnable.
Supply & Filling compresor oil super quality grade D-68 suitable for AC plant compressor.
Supply & Fixing Ball valves high Pressure of PTMT with epoxy coated Aluminium rod & highdenesity plastic ball screwed for iron Pipeand fixed of size 25 mm dia complete all as specified and directed.
Supply and fixing Expansion Valve 10 Ton.
Supply and fixing Expansion Valve 40 Ton.
Supply and fix Solenoid Valve 3 way size 1/4"x1/4"x1/3" coil voltage 230 Volt type S-189 Complete.
Supply and fixing of Butter fly Valve 50 mm dia with all acessories for iron Pipe and fixed all as specified and directed by Engineer-in-Charge.
Supply and Fix Butterfly valve 65mm dia with all accessories, complete all as specified and directed by Engineer-in-Charge.
Supply and Fix Gun Metal gate Valve 40 mm Dia Complete all as specified and directed.
Supply and Fix Gun Metal gate Valve 25 mm Dia Complete all as specified and directed.
Supply and fix GI Pipe Medium grade 50 mm dia with all fittings and fixed complete to walls and ceilings or laid in floors all as specified and directed.
Supply and fix GI Pipe Medium grade 40 mm dia with all fittings and fixed complete to walls and ceilings or laid in floors all as specified and directed.
Supply and fix GI Pipe Medium grade 25 mm dia with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-Charge.
Material and labour for Preparation of Old Surface of Central type AC plant of 7.5 TR to 52 TR capacity , preparing the surface by rubbing with fine emery paper and making the surface smooth and re-painting with two coats of super quality synthetic enamel paint by Spray gun fully matched with its original colour and making good all equipment and including Marking SM/MES No on Plants , LT panel with diffrent Paint maintaning colour code complete all as specified and directed by Engr in Charge to the following :- (i) Compressor and Motor with Channel including Foundation -03 nos (ii) Condensor Pump Set-02 Nos (iii) AHU-01 Nos (iv) LT Control Panel Complete (v) Liquid / Suction line (vi) GI Water Pipe Line (vii) Cooling Tower Complete.
All as per Item No. 48 here in before but Package type AC plants of 5.5 TR to 17 TR capacity consisting of the following :- (i) Package type AC Plants unit Complete-03 Nos (ii) LT Control Panel (iii)Out door condensing Unit Complete with Blower fan -03 Nos (iv) Liquid/Suction Line
Material and labour for rewinding of Motor 7.5/5.0 HP capacity complete with suitable copper winding wire of same gauge including earthing , removing of Old U/S burnt wire , varnishin all as directed by Engineer in Charge.
Material and labour for rewinding of Motor 3/2/1 HP capacity complete with suitable copper winding wire of same gauge including earthing , removing of Old U/S burnt wire , varnishin all as directed by Engineer in Charge.
Dismantling the Condensor unit of Package type AC Plant of any capacity , descaling the copper tubing by using appropriate method as required with appropriate quality of descaling solution including replacement of gasket, assembling, testing complete all sa directed by Engineer-in-Charge.
Material and labour for replacement of Spray nozzles for cooling tower of Size 20 mm dia complete all as specified and directed by Engineer-in-Charge.
Replacement of Indicator Lamp Type E-8 (Neon lamps).
Material and labour for replacement water pressure gauge range 0-150Kg/cm2 or 0-150 Lb/in2.
Supply and fix Contactor type CHNT NC-1-40 Coil voltage 220-240 Volt CE suitable for 2x52 TR Central type AC Plant complete all as specified and directed by Engineer-in-Charge.
Material and labour for Reprograming/ redownloaded the Software for automation/running hours for Compressor of central type AC Plant capacity 30 TR installed at 3001 Sqn, Soft Ware installed as per Voltas Company norms by the Votas Company soft ware Engineer including testing commissioning complete all as specified and directed by Engineer-in-Charge. Make - Voltas , Model VLRP Single SHAPL/2K6-06 Type - Delux range -61614 Aux Supply -12 V-8V.
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6.30 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meter deep below normal ground level connected to galvanized earth strip of size 32 x 6mm, 7.5m long means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No - 3 of SSR part I 2009 connecting to earthing test point and testing on completion with and including PCC pit in mix 1:3:6 type c1 with RCC 1:2:4 type B-1, 40mm thick cover reinforced with 6mm dia MS bars 3 Nos both ways with lifting book made out of 6mm dia bar, watering arrangement with funnel and wire mesh and 20mm bore light grade GI watering pipe, common salt and charcoal filling, necessary excavation and earth work, complete all as directed.
Supply and laying in trenches/fixing on wall/pole,jointing and testing electric under ground LT XLPE cable 16 Sqmm 4 Core PVC insulated armoured heavy duty aluminium conductor cable 1100 volts grade in trenches, ducts, pipe on walls poles complete all as specified and directed.
Supply and fix Rotational moulded Polythylene water storage tanks (Cylindrical Vertical with closed top) hoisted and fixed in position of Capacity 2000 Litres all as directed.
Supply and fix galvanised Iron Strip 32x6 mm with saddles and fixing screws etc complete all as specified and directed.
Supply and fix Indoor/Outdoor typr Thermo/Hygrometer tripple display ( Temp,Humidity & Time ) including Battery 1.5 Volt.
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in deep for foundation of poles/stays/cables/Pipe lines etc and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in including spreading, leveling, watering and well ramming in layers each not exceeding 25 cm thickness complete all as specified and as directed by Engineer-in-Charge.
Removing surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge.
Material and labour Fazilka sand as in sand cushioning to under ground cable including punning down all as directed at site.
Material and labour brick protection cover to electric cable with class 'B' bricks laid dry and flat abutting each other with gap between adjascent not exceeding 10mm.
Material and labour for Synthetic Insulating Mat for Electrical Instrument of size 2mx1mx10mm complete all as specified and directed by Engineer-in-Charge.
Rewinding of squirrel cage induction electric motor of capacity 40.0 HP 3 phase with copper wire of appropriate gauge including replacement of ball bearing of existing size complete all as specified and as directed by Engineer-in-charge.
Rewinding of squirrel cage induction electric motor of capacity5 HP 3 phase with copper wire of appropriate gauge including replacement of ball bearing of existing size complete all as specified and as directed by Engineer-in-charge.
Supply and fixing Sheet metal supply air duct made as per IS -655 of the following sizes of GI Sheet reolacing with existing duct in Central/Package AC room:-
24 Gauge galvanised Sheet steel.
22 Gauge galvanised Sheet steel.
Descaling the condenser (set of three) of Central type AC Plant after opening the condenser by using descaling liquid, cleaning with brush, pressure pump and complete washing of all tube and re-assembling the condenser including replacement the gasket , nut and bolt complete all as specified and as directed by Engineer-in-Charge.
Supply & Fixing shaft seal assambly cat part No H-05.
Supply and fix Sensor (automatic control for Compressor) Suitable for Central type AC Plants chilled water System complete all as specified and directed by Engineer-in-Charge.
Supply and fix Strip Heater of capacity 3 KW with ISI Marked including all electical connection complete all as specified and directed by Engineer-in-Charge.
Supply and fix humidifier of rating 6KW heating element with all necessary connections including feeding supply from feeder box to humidifier by using copper control cable of 4sqmm 4core all as specified and directed by Engr in Charge
Supply and fix copper control cable of 4sqmm 4 core all as specified and directed by Engr in Charge
Supply and fix humidity Controller to maintain humidity within 50% + 5% for Central type AC Plant with all acessories complete all as specified and directed by Engineer-in-Charge.
Supplying ,laying/fixing, testing and commissioning of condensor water pipes of MS class 'B'as per IS-1239 inside building including necessary clamps , vibration isolators and fittings such as bends , tees etc but excluding strainer and gauges etc adequately supported on rigid supports including necessary welding works complete all as specified and directed , of following sizes :-
65 mm dia.
50 mm dia.
Material and labour for repair of condenser and fixing of leakage by testing leakage by using CO2 gas, rectifying the leakage all as specified and directed by Engineer-in-Charge.
Material and labour for descaling of cooling towers using descaling solution cleaning with brush pressure pump and complete washing of all tube and reassembling the condenser including replacement the gasket nut bolt complete all as specified and as directed by Engr in Charge
Material and labour for replacement of 5/5.5 TR scroll type compressor including dism. The old from unit and then new compeletly with reharging the efrigrant suitable all as directed by Engineer-in-Charge.
Material and labour for replacement of 8.5/9.5 TR scroll type compressor including dism. The old from unit and then new compeletly with reharging the efrigrant suitable all as directed by Engineer-in-Charge.
Supply and fix Sprinkler for cooling towers of suitable size all as specified and directed by Engineer-in-Charge.
Material and labour for replacement of dryer assy including testing of leakage of pipes connecting to it all as directed by Engr in Charge
Material and labour for blade assy. For cooling tower all as directed by Engr in Charge
Material and labour for replacement of UC 205/206 bearing all as directed by Engr in Charge
Material and labour for replacement of solenoid valve of 20TR capacity all as directed by Engr in Charge
Material and labour for replacement of oil pump for any capacityall as directed by Engineer-in-Charge.
Supply and fixing motor protection device (MPD) FOR PACKAGE TYPE ac PLANT SUITABLE FOR 17tr CAPACITY AS PER SAMPLE.
Material and labour for attending of central/package plant gas leakage control panel wiring,compressor failure,sensor issue,blower,chiler or any other issue resulting in non functioning og plant throughly by rep of concerned VOLTAS/BLUESTAR all as specified and as directed by Engineer-in-Charge.
Supplying installing of external thermal insulation on ducts after out the old insulation with closed cell nitrile rubber insullation as per ASTM G797 standard class o IMO Ä653(16) fm global & UL-94 approved ,density 40-55kg/m3.Temperature of 50to 116 degree cel and thermal conductivity of 0.036W/mk water vapor permissibility as per EN 12086 all as specified and as directed by Engineer-in-Charge.
Supply and fix SINGLE PHASE PROTECTION DVICE(SPP), 50HZ FOR CENTRAL TYPE ac PLANT SUITABLE FOR 30tr CAPACITY all as specified and directed.
Supply and fixing display unit with card having numerical control system for package type AC plant including blower unit ,condensor unit,compressor ON/OF and start/stop & settimg push button all as specified and directed by Engineer-in-Charge.
Supply & fix 4 pole Isolator conforms to IEC60947-3.50 Hz,Rating 63 Amps Operating Voltage 240 V/415V.
Supply & fix 3 Pole MCB TP 32 Amps operating Voltage 240 V/415V.
Supply and fix MCB TPN Ç'curve,50 Hz Rating 63 Amps. 10 KA, Operating Voltage 240V/415V.
Supply and fix MCB TPN Ç'curve,50 Hz Rating 40 Amps. 10 KA, Operating Voltage 240V/415V.
Material and labour for instruction Board how to operate AC Plant installation adn safety precaution writing in Hindi or Punjabi on practical board 30mm thick of size 1.5m x2.5 m with suitable aluminium framing complete all as specified and as directed. Note. Writting notes safety instruction will be given by the concern JE/AGE E/M.
Material and labour for CPVC pipe of dia 25mm with all fittings complete all as specified and directed.
Dismantling/taking down Split type AC 1.5/2 Ton from site, opening, cleaning all dust with the help of air blower including cleaning of condenser and evaporator coil with Soap solution, removing the dust with the help of wire brush, repairing & proper fixing of wiring including thimbles and replacement of air filter Nylon and reinstalling AC in the same location both unit outdoor/indoor unit complete and testing on full load etc complete all as specified and as directed.
Supply and fixing starting relay assembly including cover and clips for air conditioner window type 1.5/2 Ton capacity fixed in replacement complete all as specified and as directed by Engineer-in-charge.
Supply and fixing starting capacitor 100/120 mfd suitable for 1.5/2 Ton capacity of window type AC fixed in replacement complete all as specified and as directed by Engineer-in-charge.
Supply and fixing running capacitor 36/45 mfd suitable for 1.5/.2 Ton capacity of window type AC fixed in replacement complete all as specified and as directed by Engineer-in-charge.
Supply and fixing capacitor 6 mfd suitable for blower motor, fixed in replacement complete all as specified and as directed by Engineer-in-charge.
Supply and fixing Remote suitable for split/window AC all as specified and directed by Engineer-in-Charge.
Taking down dismantling of old unserviceable defective sealed compressor of cap 1.5 TR of window type AC and replacement with manufactures reconditioned compressor company make hermatic sealed compressor of cap 1.5 TR by soldering /brazing of copper Tubes and replacement of foundation pads including nut& bolt and washers as required and charging with Refrigerant R-22 to its rated capacity and testing of leakage in the system if any and making good, Testing on full load after reinstalling the same.
Supply and fixing in replacement fan blade for window/split ACof 1.5/2.0 TR all as specified and directed by Engineer-in-Charge.
Material and labour for rewiring of complete window type AC of capacity 1.5 Ton with copper wire single core PVC cable of size 40/0.0076 with necessary sleeves, clip , thimble auto sweep switch etc.
Supply & Fix cable of 3 core PVC sheathed copper flexible cable of size 70/0.0076 fixed in replacement complete all as specified and directed.
Supply and fixing Metal clad plug/socket ‘top’ 15 Amps fixed in replacement complete all as specfied and directed.
Supply and fixing single pole and neutral enclosure with, two pin and earth plug and socket 240 volts complete with one MCB 20/25 Amps including taking down existing all as specified and directed by Engineer-in-Charge.
Supply and fixing Blower motor single phase 230 volts, 50 Hz, 1/5 HP, 900 RPM suitable for window type AC of capacity 1.5 Ton fixed in replacement complete all as specified and directed
Supply and fixing Filter pad nylon type suitable for window type AC of capacity 1.5 Ton fixed in replacement complete all as specified and directed .
Supply and fixing Evaporator coil assembly complete suitable for window type AC of capacity 1.5 Ton etc complete and recharging the refrigerant R-22 and testing fixed in replacement complete all as specified and directed by Engineer-in-charge.
Supply and fixing Condensing coil assembly complete suitable for window type AC of capacity 1.5 Ton etc complete and recharging the refrigerant R-22 and testing fixed in replacement complete all as specified and directed.
Supply and fixing Front grill assembly complete suitable for window type AC of capacity 1.5 Ton fixed in replacement complete all as specified and as directed.
Material and labour for Cleaning the gas system with anti corrosive solution and recharging the refrigerant gas R-22/R-134a/R-410 with anti moisture substance and replacement of filter along with rectification of leakage system in the window type AC of capacity 1.5 Ton including installation at site and testing on full load complete all as specified and as directed by Engineer-in-charge.
Material and labour for rewinding of blower motor of window type AC 1.5 Ton capacity single phase 1/5 HP, 900 RPM with super enameled copper wire of existing gauge including replacement of bush and nut and bolts, washer etc complete all as specified and as directed by Engineer-in-charge.
Supply and fixing Blower and blade assembly complete suitable for blower motor of window type AC of capacity 1.5 Ton fixed in replacement complete all as specified and as directed by Engineer-in-charge.
Material and labour for repair to voltage stabilizer of capacity 04/05 KVA single phase including replacement of circuit plate, starting relay, voltmeter, fuse terminal box with fuse carrier, rewinding the main transformer with copper wire of existing size and repair / replacement time delay relay (1-2 Min) built-in type designed for low cut off 140/160 volt, high cut off 260/280 volt on single phase, 50 cycle AC supply etc complete all as specified and as directed by Engineer-in-charge
Preparation of old painted surface and applying two coats of Ducco paint by spray gun fully matched with its original colour outside of the window type AC of capacity 1.5/2 Ton including before painting removal of all dust with the help of air blower, sand paper and rubbing with cleaning compound and polishing on painted surface etc complete all as specified and as directed by Engineer-in-charge.
Taking down /dismantling of old unserviceable defective sealed compressor of cap 2/1.50 TR of Split type AC and replacement in with manufactures reconditioned compressor company make hermatic sealed compressor of cap 2/1.50 TR by soldering /brazing of copper Tubes and replacement of foundation pads including nut& bolt and washers as required and charging with Refrigerant R-22/R-134a/R-410 to its rated capacity and testing of leakage in the system if any and making good, Testing on full load after reinstalling the same.
Taking down /dismantling of old unserviceable defective Rotary compressor of cap 2/1.5 TR of Split type AC and replacement in new rotary compressor of cap 2/1.5 TR by soldering /brazing of copper Tubes and replacement of foundation pads including nut& bolt and washers as required and charging with Refrigerant R-22/R-134a/R-410 to its rated capacity and testing of leakage in the system if any and making good, Testing on full load after reinstalling the same. Make-Kirloskar Copland/Voltas/gmcc.
Material and labour for Cleaning the gas system with anti corrosive solution and recharging the refrigerant gas R-22/R-134a/R-410/R-32 with anti moisture substance and replacement of filter along with rectification of leakage system in the split type AC of capacity 1.5/2 TR) Ton including installation at site and testing on full load etc complete all as specified and as directed by Engineer-in-charge.
Supply and fixing decorated frame of plywood/teak ply of size 70mm wide and 3mm thick duly varnished of good quality, all around the window type AC for air tight and fixing with screws on existing wooden frame complete all as specified and as directed by Engineer-in-charge.
Supply and fixing Insulation to refrigerant pipes of split ACs any make & type complete with suitable size for suction and discharge refrigerant pipes including necessary clamps etc.
Supply and fixing thermostat suitable for split/window AC all as specified and directed by Engineer-in-Charge.
M &L for dismantling/taking down of existing Split type AC of cap 2.0/1.5 TR complete with Indoor/Outdoor unit from existing location with all Electric Connection and all refrigerant Pipes and matching the existing disturbed surface area, Including Refixing/Re-Installation of Split type AC Shifted to new location on suitable wall places complete all as specified and directed by Engineer-in-Charge. (Refrigerant Recharging gas, Insulation of Copper tubes, copper tubes paid & measured seprate under respective item).
Material and labour for Copper Pipe Line of size 1/2" for Split type AC of any capacity complete all as specified and directed by Engineer-in-charge.
Material and labour for Copper Pipe Line of size 1/4"for Split type AC of any capacity complete all as specified and directed by Engineer-in-charge.
Material and labour for dismantling /Taking down of Window type AC 2/1.5 Ton Capacity from existing location carefully with all electric connection and connecting the same in new location and including the window opeaning filled with the brick masonary and cement plastering to match the existing disturbed surface area complete all as specified and directed by Engineer-in-Charge.
Material and labour for Opeaning/Cutting holes in Brick wall suitable for window type AC 2/1.5 Ton and making good disturbed surface area complete with cement plaster and masonary work equired at site and made Air tight to Opeaning with the Thermocoal Material all round the window AC etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Starting relay assembly suitable for W/cooler of capacity 40/40, 40/80, 60/120, 120/150 Ltrs fixed in replacement , complete all as specified and as directed by Engineer-in-charge.
Supply and fixing Evaporator coil assembly complete suitable for Split type AC of capacity 1.5 Ton etc complete and recharging the refrigerant R-22 and testing fixed in replacement complete all as specified and directed by Engineer-in-charge.
Supply and fixing Condensing coil assembly complete suitable for window type AC of capacity 1.5 Ton etc complete and recharging the refrigerant R-22 and testing fixed in replacement complete all as specified and directed by Engineer-in-charge.
Material and labour for fixing of duel capacitor suitable for both window/split AC all as specified and directed by Engineer-in-Charge.
Material and labour for replacement of complete indoor unit of split AC of 1.5/2TR all as specified and directed by Engineer-in-Charge.
Material and labour for replacement of complete outdoor unit of split AC of 1.5/2TR all as specified and directed by Engineer-in-Charge.
Supply and fix PC control board suitable for split/window AC 2/1.5ton all as specified and directed by Engineer-in-Charge.
Material and labour for attending day to day complaint of detecting the fault like loose nut and bolts,leakage of tube,checking electrical connections,charging of refrigerant, fan motor, compressor fault etc all as specified and directed.
Supply and fixing in replacement Blower assembly complete for Split AC of 1.5/2.0 ton as per existing all as specified and as directed.
Supply and fixing in replacement LCD Digital type AC time for cyclic operation of 02 any type of Air Conditioner with displaying AC 1/ AC 2 on indication & 1 to 24 hours programmable to take load upto 2 Ton window or split AC with auto/ manual facility at site all as specified and as directed.
Aman Enterprises
M/s Vee Kay Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .