Loading…
Loading…
Tender Value
₹5.8 Cr
EMD Value
₹4.4 L
Closing Date
17 Mar 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
65 days
Expenditure
Capital (Works)
Above/Below/Par
SIGNAL
15 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- Any kind of signaling or Telecom indoor work with or without outdoor work, with supply of materials.
Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of opening of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
42 conditions · 5 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
GST Registration details should be attached
Tenderers will examine the various provisions of The Central Goods and Services Tax Act, 2017(CGST)/ Integrated Goods and Services Tax Act, 2017(IGST)/ Union Territory Goods and Services Tax Act, 2017(UTGST)/ respective state's State Goods and Services Tax Act (SGST) also, as notified by Central/State Govt & as amended from time to time and applicable taxes before bidding. Tenderers will ensure that full benefit of Input Tax Credit (ITC) likely to be availed by them is duly considered while quoting rates.
The successful tenderer who is liable to be registered under GST/IGST/ UTGST/SGST Act shall submit GSTIN along with other details required under CGST/IGST/ UTGST/ SGST Act to railway immediately after the award of contract, without which no payment shall be released to the contractor. The contractor shall be responsible for deposition of applicable GST to the concerned authority.
In case the successful tenderer is not liable to be registered under GST/IGST/UTGST/ SGST Act, the railway shall deduct the applicable GST from his/their bills under reverse charge mechanism (RCM) and deposit the same to the concerned authority.
Every tenderer shall state in the tender his postal address fully and clearly. Any communication sent in time to the tenderer by post at the said address shall be deemed to have reached the tender duly and in time. Important documents shall be sent by Registered post.
The provision of Construction and Demolition Waste Management Rule 2016 issued by Ministry of Environment Forest and Climate Change dated 29.03.2016 and published in the Gazette of India, Part - II, Section -3, Subsection (ii) are binding upon the Contractor. Contractor shall implement these provisions at worksites, for which no extra payment will be payable.
Before submitting a tender, the tenderer will be deemed to have satisfied himself by actual inspection of the site and locality of the works, that all conditions liable to be encountered during the execution of the works are taken into account and that the rates he enters in the tender forms are adequate and all inclusive to accord with the provisions in Clause-37 of the Standard General Conditions of Contract for the completion of works to the entire satisfaction of the Engineer
The Railway reserves the right to verify all statements, information and documents submitted by the bidder in his tender offer, and the bidder shall, when so required by the Railway, make available all such information, evidence and documents as may be necessary for such verification. Any such verification or lack of such verification, by the railway shall not relieve the bidder of its obligations or liabilities hereunder nor will it affect any rights of the railway there under.
The following documents should be submitted by the tenderer on issue of LOA and before signing Contract Agreement:-.
The documents pertaining to Deployment of Qualified Engineers at Work Sites by the Contractor.
EPF & ESI Registration certificate should be submitted before signing of Contract Agreement.
Price variation clause (PVC) shall be applicable only in tender having advertised value above Rs. 2 crore provided further that, in a tender document PVC is applicable.
All the Terms and Conditions in this contract is as per Indian Railways Standard General Conditions of Contract updated with correction slips issued up to date of inviting tender or as otherwise specified in the tender documents
If the tenderer(s) expire(s) after the submission of his / their tender or after the acceptance of his / their offer, the Railway shall deem such tender cancelled. If a partner of a firm expires after the submission of their tender or after the acceptance of their tender, the Railway shall deem such tender as cancelled, unless the firm retains its character.
Contractor is to abide by the provisions of Payment of Wages act & Minimum Wages act in terms of clause 54 and 55 of Indian Railways General Condition of Contract. In order to ensure the same, an application has been developed and hosted on website 'www.shramikkalyan.indianrailways. gov. in'. Contractor shall register his firm/company etc. and upload requisite details of labour and their payment in this portal. These details shall be available in public domain. The Registration / updation of Portal shall be done as under:-
Contractor shall apply for onetime registration of his company/firm etc. in the Shramikkalyan portal with requisite details subsequent to issue of Letter of Acceptance. Engineer shall approve the contractor's registration in the portal within 7 days of receipt of such request.
Contractor once approved by any Engineer, can create password with login ID(PAN No.) for subsequent use of portal for all Letter of Acceptances (LoAs) issued in his favour.
The contractor once registered on the portal, shall provide details of his Letter of Acceptances (LoAs) / Contract Agreements on shramikkalyan portal within 15 days of issue of any LoA for approval of concerned Engineer. Engineer shall update (if required) and approve the details of LoA filled by contractor within 7 days of receipt of such request.
After approval of LoA by Engineer, contractor shall fill the salient details of contract labours engaged in the contract and ensure updating of each wage payment to them on shramikkalyan portal on monthly basis.
It shall be mandatory upon the contractor to ensure correct and prompt uploading of all salient details of engaged contractual labour & payments made thereof after each wage period.
While processing payment of any 'On Account Bill' or 'Final Bill' or release of 'Advances' or 'Performance Guarantee / Security deposit', contractor shall submit a certificate to the Engineer or Engineer's representatives that "I have uploaded the correct details of contract labours engaged in connection with this contract and payments made to them during the wage period in Railway's Shramikkalyan portal at 'www.shramikkalyan. indianrailways.gov.in' till Month, Year."
Provision of Power Supply redundancy of both system of BPAC (HASSDC/Dual SSDAC) at stations of Lumding Dvision
SNT-42-LMG-2025-26
SNT-42-LMG-2025-26
Open
Works - General
365 Days
Hojai, Assam
₹0
₹4.4 L
17 Mar 2026
20 Feb 2026
3 Mar 2026
31 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 5,77,89,732.66 | ||
| — | 216.00 | — | — | ||
| Supply of DC-DC converter 24- 40V/5 or 10 Amp. suitable for Amararaja make IPS system as per RDSO specification No. RDSO/SPN/165/2012 (Ver. 3.0) or latest. | — | — | — | 43,68,006 | |
| — | 900.00 | — | — | ||
| Double walled corrugated (DWC) HDPE duct (Pipe) of size 90 mm / 67 mm (min), standard length 6 mtr ± 1% each as per RDSO specification No. RDSO/SPN/ 204/2011/Version: 1.1 or with latest amendment, detail as per technical specification. | — | — | — | 2,36,961 | |
| — | 900.00 | — | — | ||
| Supply, laying and fixing of GI pipe medium grade to carry all cables with fixing of material and making necessary entry arrangement at LC gates , ASM room/class D station/OFC room/other buildings, bridges as per TS | — | — | — | 4,97,979 | |
| — | 114.00 | — | — | ||
| Surge Protection Device (SPD) Type-II (C Type) in a set of 3 for connecting at the Output of IPS ( L1- L2, L1- E & L2- E) for extending 24V DC Power for BPAS/HASSDAC. SPD shall be of Nominal Voltage: 24-60 V AC/DC and other parameters as per RDSO specification of IPS vide no. RDSO/SPN/165/2023 Ver.4 Amd-1 or latest. | — | — | — | 3,16,562.04 | |
| — | 114.00 | — | — | ||
| Fixing, Wiring & installation for extending IPS Power supply which includes following:- (1) Installation of DC- DC Converter ( upto 5 nos) in existing IPS system if required, (2) Fixing, wiring/ connection of DC DC Module as per OEM practice, (3) Fixing & wiring of SPD at the Output of IPS module with Contractor own lugs & other required materials if required (supply of SPD not in this scope), (4) Extending power supply from IPS system to CTR/ Power distribution panel with proper casing capping if required and neat & clean dressing for further extending it to field equipment, (5) Fixing & wiring of Fuse base with NDT fuse of required capacity (supply of fuse & fuse base are in scope of contractor) and Fixing & wiring SPD at Location Box if required (supply of SPD not in this scope), (6) Alteration in existing power supply wiring at Location box of BPAC/HASSDAC as per latest TAN for . Scope of this work is at each station i.e. Fixing, Wiring, installation etc in Relay Room, Both side Location Huts &/or Location Box. Cables/ wires required for the purpose, will be provided by Railway but casing, capping, cable tie etc if required, these shall be arranged by the Contractor. Whole work is to be done as per direction of Consignee or his authorised JE/SSE. | — | — | — | 7,46,700 | |
| — | 14240.00 | — | — | ||
| Execution of HDD boring as pe TS. | — | — | — | 2,03,15,780.8 | |
| — | 190000.00 | — | — | ||
| Excavation of trench 1.2 mtr deep, 0.3 mtr wide at the bottom along railway track in all type of soils (except rocky area), including clearing of bushes, trees, temporary obstruction, bailing out water from the trench etc. and refilling of the trench by excavated soil and ramming after laying of the required quantity of cables as per instruction of Engineer at site. | — | — | — | 1,45,86,300 | |
| — | 10000.00 | — | — | ||
| Digging of 1.00 Meter deep and 0.3 Meter wide trenches including clearing of roots of trees and bushes and temporary obstruction on rocky/ballast filled soil/Road crossing/ track crossing/ platform crossing as per technical specifications. | — | — | — | 55,59,800 | |
| — | 14000.00 | — | — | ||
| All works of excavation of cable trench 1.0 Meter deep, 0.3 Mater wide on pucca platform / on Road for road crossing and restoration of the platform/Road surface/Track to original condition with contractor's material, after laying of GI/DWC pipes and then re-filling the trench as per Technical Specifications. | — | — | — | 83,22,580 | |
| — | 2400.00 | — | — | ||
| Laying of RCC/ DWC pipes including carrying from the stock of central place (or stocking place) at station to the work spot without causing any damage and placing them in the trench duly clearing the ballast per track crossing/ down the culvert in the trench, gap between DWC/ RCC pipes and collar has to be closed using cement mortar . Materials viz. collars for the joints, cement mortar for closing gaps between collar and pipes are to be supplied by contractor (this excludes the supply of DWC/ RCC pipes) | — | — | — | 1,44,552 | |
| — | 220000.00 | — | — | ||
| Laying of S&T Cables of various cores/pairs/quads in trenches/GI pipes/RCC/DWC pipes/trunking with laying of these including laying of cables in track crossings & road crossings as per TS. | — | — | — | 10,47,200 | |
| — | 1200.00 | — | — | ||
| Termination of Power cable/wire as per below TS- Each core of underground cable (used or spare) shall be terminated in the respective terminal boards provided in SMs room, Relay room, Battery cum Generator room, Location huts, Apparatus cases, Junction boxes, Boot legs and also at the functions as per approved termination diagrams and circuit diagrams. Each core of every cable, terminated as above shall be provided with identification tags/ferrules/tapes with letters and numbers embossed/printed on them to indicate name of the circuit which the particular core carries. In addition to above, the name of the circuit shall be painted against each core on the respective terminal board including indication for spare cores. Power cable carrying 230V AC, if required to be terminated, should invariably be done as mentioned below:- 1. In location huts, on a separate termination board other than the Relay-cum-cable termination rack. 2. In Apparatus cases, on the backside of the Termination Board. 3. In case of junction boxes, on separate junction boxes which has no termination of signaling cable or 110V power cable. | — | — | — | 21,708 | |
| — | 114.00 | — | — | ||
| Taking the all types of cables inside station relay rooms, location hut and/ or Location Box at both end and sealing of cable entry pit etc. as per Technical specifications, complete with contractors's material. | — | — | — | 9,21,300.12 | |
| — | 30.00 | — | — | ||
| Cement concrete work for miscellaneous items in the ratio 1 : 3 : 6, aggregate not exceeding 3 : 8 cm including excavation,raming, curing and plastering with 1 : 4 cement - sand mixture complete with contractor's material including cement, sand, aggregate and curing of casted foundation, refilling & ramming of loose soil around foundation and disposal of loose dugged soil from site. | — | — | — | 94,016.1 | |
| — | 114.00 | — | — | ||
| Transportation of miscellaneous signalling materials such as UG cables, point machines, location box, ELB complete set, CLS unit, post, base, ladder, relays, EI system complete, racks, furnitures, pipe etc including all other materials required for the work from consignee's godown/yard/mid section up to work site by Truck of minimum 10 ton capacity including loading & unloading as per technical specification. This includes loading, transportation of DWC (HDPE) pipe from store of SSE/Sig/IC of division to the site. (Nos= Trip) | — | — | — | 6,10,287.6 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Tender Document
ATTACHMENT
TenderDocSNT-42-25-26BPACnew.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .