Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.9 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹11.3 L+₹41,161 (3.78%)Rejected-Finance HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹13.5 L+₹2.6 L (24.2%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | Rejected-Technical 403 GH MANSADEVI COMPLEX PANCHKULA 134109 HARYANA | PANCHKULA | HARYANA | 134109 | - | Rejected-Technical Not Recommended to open financial bid due to adverse remarks in WLR for QE Sep 2020 of HQ CE Lucknow Zone vide their letter No 980803/P-2/Sep-20/15/E8(LZ) dated 21 Nov 2020. | |
| 5 | Rejected-Technical | - | Rejected-Technical Not recommended open financial bid, being not enlisted in c (i) category |
Tender Value
Refer Docs
EMD Value
₹29,420
Closing Date
15 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col S S Babu
Headquarters 138 Works Engineers Pin-914138 C/O 56 APO
INSTALLATION OF ADDITIONAL FAN COIL UNIT (FCUs) AND ITS CONNECTED ITEMS UNDER GE 865 EWS
2020_MES_393980_2
138WE/L-46/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 865 EWS
As per NIT
8 documents required · 8 mandatory
₹500
GE 865 EWS
₹29,420
Yes
30 Jan 2021
18 Nov 2020
17 Dec 2020
18 Nov 2020
15 Dec 2020
2 Dec 2020
60 days
Amount
Dismantling wall and ceiling boards (fiber, pulp, inlsulation,etc) or insulation boards/slabs/blankets ,any thickness including covered fillets complete all as specified and as directed.
S&F Anodised aluminium snap grid frame work for false ceiling including hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long, complete all as specified and as directed.
M&L for 12mm thick perforated particle board/tiles for insulation and acoustic purposes, 60cm x 60cm in size, fixed with nails to timber frame work or with staples on snap grid or with staples on snap grid, complete all as specified and as directed.
M&L for Preparation of existing surface of walls and applying two coats of oil bound distemper over a coat of primer and over 3mm thick wall care putty complete all as specified and as directed.
M&L for 9mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, medium density, fixed with nails/ screws to timber frame work complete all as specified and as directed.
M&L Prelaminated particle board, 18/19mm thick,exterior grade, prelaminated both side with decorative choice lamination, fixed with screws to aluminium frame work complete all as specified and as directed.
Dismantling timber scantlings fillets, rails, posts, rafters, purlins, etc, under 40 Sqcm in section, complete all as specified and as directed by Engineer-In-Charge.
Plain fillets of 2nd class soft wood, square, rectangular or triangular in section, clean sawn, secured with nails or brads of sectional area exc 13 sq.cm & not exc 25 sq.cm, complete all as specified & directed.
Taking down cement plaster on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and as directed.
Rendering 15 mm thick using water proofing compound @3% of cement on other than fair faces of brick work, in cement mortar 1:6, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer(chalk whiting) complete all as specified and as directed.
Rendering 10 mm thick on brick work or concrete surfaces in cement mortar 1:4 finished even and smooth (without using extra cement) complete all as specified and as directed.
Demolition of brick work or PCC block work or stone masonry work built in cement mortar including all quoins, arches pillars etc built in cement mortar complete all as specified and as directed.
M&L for Precast cement concrete block masonry set in CM 1:6 & casted in cement concrete type C-1 (1:3:6) using 20mm graded curshed stone aggregates complete all as specified and as directed.
Demolition of cement concrete in ground floor and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed.
M&L for cement concrete type D-2, (1:4:8) using 40mm graded crushed aggregate as in mass concrete and filling of foundation complete all as specfed and as drected.
Material and Labour for reinforced cement concrete 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) for slab supported on walls, beams and columns in floors, roofs, landings, shelves and the like complete all as specified and as directed.
Form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves, overhangs etc complete all as specified and as directed.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Mild steel TMT bars 8mm dia and over upto and including 10mm dia in stirrups, spacers bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed.
M&L for cutting holes exc one brick but not exc two bricks in brick walls in cement mortar or cement lime mortar and stone walls built in cement mortar for inserting pipes and making good to the dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required, complete all as specified and as directed.
Supply and fixing of Chilled/Hot Water Fan coil unit (FCU) Vertical type Floor Mounting 600/1.5TR (CFM/TR) capacity complete all as per manufacturer's instructions and as directed. Make: Carrier/Zeco/Universal or equivalent ISI Marked.
Point wiring for one light point or fan point controlled by one switch with 2.5 Sqmm, PVC insulated, unsheathed, FRLS single core, multi-stranded, copper conductor cable, 1100 Volts fire resistance ISI, drawn in and including PVC casing and capping, fire resistance, ISI marked, fixed surfaces of walls and ceilings, terminated in and including rectangular PVC board for mounting fitting/ switches/ sockets and 2.5 Sqmm, copper conductor, multi-stranded, FRLS as earth continuity wire connected to earth terminal, including making good to disturbed surface as matching to existing descriptions/ specifications, complete all as specified and as directed..
Switch socket combination 2-in-1, 3 pin 5 and 15 Amps, flush type,universal complete all as specified and as directed.
Cutting the 125mm existing pipe line using of welding machine and connection of new MS pipe 50mm dia with accessories complete all as specified and as directed.
Supply, fixing and testing MS ERW tubing 50mm bore heavy grade Class 'C' with welded ends laid in ducts over the angle iron supports/fixed on the walls including fitting complete all as specified and as directed. (Note :- The item rate is inclusive of cutting to any levels/shapes like elbows, tees etc, welding jonts wherever necessary as per the site requirement).
Supply, fixing and testing MS ERW tubing 40mm bore heavy grade Class 'C' with welded ends laid in ducts over the angle iron supports/fixed on the walls including fitting complete all as specified and as directed. (Note :- The item rate is inclusive of cutting to any levels/shapes like elbows, tees etc, welding jonts wherever necessary as per the site requirement).
Supply, fixing and testing MS ERW tubing 20mm bore heavy grade Class 'C' with welded ends laid in ducts over the angle iron supports/fixed on the walls including fitting complete all as specified and as directed. (Note :- The item rate is inclusive of cutting to any levels/shapes like elbows, tees etc, welding jonts wherever necessary as per the site requirement).
S&F in insulation with aluminium foil 13mm with all fixing arrangements to the all sizes of pipes mentioned from Srl item No. 26.00 to 28.00 above properly complete all as specified and as directed. Make: Caflese, K-Flex.
S&F in inlet forged brass ball valve 20mm with Y stainer for FCU, including supply and fixing MS/GI nipple of size 20mm including welding work, cutting the existing MS/GI nipple complete all as specified and as directed. Make: Rapid cool/Sant/Kirloskar
S&F in inlet forged brass ball valve 50mm with Y stainer for FCU, including supply and fixing MS/GI nipple of size 50mm including welding work, cutting the existing MS/GI nipple complete all as specified and as directed. Make: Rapid cool/Sant/Kirloskar
S&F in FCU connection flexible pipe 20/16mm as per existing, complete all as specified and as directed. Make- Jindal/Kitetac.
SUMEET TRADING CORPORATION
Hitech Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .