Loading…
Loading…
Tender ID
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC NO 1 RANGAJAN VILLAGE PO BOKULONI CHARIALI MAUZA TIPLING SUB DIVISION TENGAKHAT DIST DIBRUGARH ASSAM 786191 | DIBRUGARH | ASSAM | 786191 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹10.4 L+₹1.5 L (16.4%)Rejected-Finance PO LEKHAPANI DIST TINSUKIA PIN 786 180 ASSAM | 786180 | L2 | Rejected-Finance BEING OTHER THAN L1 | |
| 3 | L3₹11.3 L+₹2.4 L (27.1%)Rejected-Finance AT MAIN ROAD DANDAI PO PS DANDAI DIST GARHWA | LATEHAR | JHARKHAND | 822112 | L3 | Rejected-Finance BEING OTHER THAN L1 | |
| 4 | L4₹11.6 L+₹2.7 L (29.9%)Rejected-Finance | L4 | Rejected-Finance BEING OTHER THAN L1 | |
| 5 | L5₹12.2 L+₹3.3 L (37.6%)Rejected-Finance NAU PUKHRI ROAD MILLAN PALLY BYE LANE 2 NEAR GOYAL PALACE PO DISTT TINSUKIA ASSAM 786125 | TINSUKIA | ASSAM | 786125 | L5 | Rejected-Finance BEING OTHER THAN L1 |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
7 Apr 2023, 6:00 pmClosed
GE LEKHAPANI
TINSUKIA, ASSAM
REPAIRS/MAINT OF INTERNAL ELECTRIFICATION WORKS AT ZONE-II,ZONE-IIII AND ZONE VI AT LEKHAPANI
2023_MES_585283_1
8723/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE LEKHAPANI
Class E and category b (i)
9 documents required · 9 mandatory
₹500
GE LEKHAPANI
₹24,000
Yes
11 May 2023
10 Mar 2023
14 Apr 2023
10 Mar 2023
7 Apr 2023
24 Mar 2023
Amount
Taking down aluminium point wiring for light, fan, bell socket, power socket etc complete including fittings and fixtures removing from site and making good disturbed surfaces of walls, floors, etc complete all as directed by Engineer-in-Charge
M&L Providing point wiring for controlled by one switch with using 1.5 sq.mm (nominal area), stranded copper conductor, single core PVC insulated FRLSH unsheathed cable (Maintaining Colour Code) 1100 volts grade with and including PVC casing and capping (size of casing caping as required at site but not less than 20mm) of suitable size including PVC accessories / fittings and fixtures fixed on surface with using new PVC board or sunken type pressed steel box of adequate size, terminal boxes for mounting fittings/junction boxes with and including all accessories and using 1.5 sq.mm (nominal area), stranded copper conductor, single core PVC insulated FRLSH unsheathed cable green in colour as in earth continuity conductor connected to common earth dolly and connecting upto fittings for one light /Fan /Exhaust Fan point controlled by one, one way switch complete all as specified and directed. Note: The quoted rates shall be inclusive for fixing casing caping to surface with using PVC raw plugs and provision of PVC boards/terminal/junction boxes of any shape and size.
All as per Item No.2 above,but one Bell/Buzzer point controlled by one way bell switch,complete all as specified and directed.
All as per Item No.2 above,but one socket outlet 3 or 5 Pin, 6 Amp on same board.complete all as specified and directed.
All as per Item No.2 above,but one socket outlet 3 or 5 Pin, 6 Amp on independent board complete all as specified and directed.
All as per Ser item No 2 above but with 2.5 sqmm copper cable in and including PVC casing and capping for socket outlet 3 or 6 pin 15 Amps.complete all as specified and directed.
M&L Providing Point wiring with 1.5 Sqmm copper conductor unsheathed, multistranded, PVC insulated, single core cable FRLSH with earth continuity conductor of 1.5 sqmm PVC insulated copper conductor and including concealed type rigid PVC conduit of suitable size but not less than 20mm dia. and all accessories fixed to the surface of the roof/ walls etc., including terminal boxes made out of MS sheet of thickness should be not lessthan 1.2mm thick for fixing of switches, fan regulators socket outlet etc along-with 3mm thick top laminated bakelite sheet and modular box for housing switches etc, for one light /Fan /Exhaust Fan point controlled by one, one way switch including making good all disturbed work to match the existing complete all as specified and as directed.
All as per Ser item No 7 above but one Bell/Buzzer point controlled by one way bell switch,complete all as specified and directed.
All as per Ser item No 7 above but one socket outlet 3 or 5 Pin, 6 Amp on same board, complete all as specified and directed.
All as per Ser item No 7 above but one socket outlet 3 or 5 Pin, 6 Amp on independent board, complete all as specified and directed.
All as per Ser item No 7 above but with 2.5 sqmm copper cable in and including concealed type rigid PVC conduit complete all as specified and as directed for socket outlet 3 or 6 pin 15 Amps.complete all as specified and directed.
S&F Switch paino flush type 5 Amps single pole one way 230 volts AC circuit complete all as specified and directed.
S&F Switch paino flush type 5 Amps single pole one way 230 volts AC circuit as fixed in repairs complete all as specified and directed.
S&F Switch piano flush type, 5 amps, 230V AC,single pole, two way as fixed in repairs complete all as specified and directed.
S&F Bell push flush type 5 Amps single pole 230 Volts AC Circuit complete all as specified and directed.
S&F Bell push, flush type, 5 amps, 230V AC,single pole, one way as fixed in repairs complete all as specified and directed.
S&F Socket outlet 2 in 1 3 pin 5 Amps flush type 230 volts AC circuit on same board complete all as specified and directed.
S&F Switch socket combination 2 in 1 3/5 pin 5/6 Amps 240 volts flush type multipurpose complete all as specified and as directed.
S&F Switch socket combination multipurpose suitable for 2 pin and 3 pin 5 amp flush type as fixed in repairs complete all as specified and directed.
S&F Switch socket combination 2 in 1 5/6 pin 5/6 Amps and 15/16 Amps flush type 240 Volts universal complete all as specified and as directed.
S&F Switch socket combination multipurpose suitable for 2 pin and 3 pin 6 and 15 amp flush type as fixed in repairs complete all as specified and directed.
S&F Electronic fan regulator 230 volts , step type,socket type ,hum free 300 watt ISI Marked,complete all as specified and directed.
S&F Electronic fan regulator 230 volts , step type,socket type ,hum free 300 watt ISI Marked,as fixed in repairs all as specified and directed.
M&L Ceiling rose, surface Bakelite 65 x 17.50 mm of three terminals PVC/Polycarbonate, isolated body (ISI Marked)
S&F Call bell AC 230 Volts single pole complete all as specified and directed.
S&F Call bell, AC, 230 V, single pole.as fixed in repairs all as specified and directed.
S&F Modular switch 6 Amp one way 230 V AC complete all as specified and directed.
S&F Modular switch 16 Amp one way 230 V AC complete all as specified and directed.
S&F Modular socket outlet 6 Amp intel multi socket for all pins 230 V AC complete all as specified and directed.
S&F Modular socket outlet 16 Amp and 6/16 Amp heavy duty 230 V AC complete all as specified and directed.
S&F Modular type fan step regulator, 120W - 2 module complete all as specified and directed.
S&F 2 module PVC Flush Box including white cover plate with frame for fixing of modular switeches/sockets etc. complete all as specified and directed by Engineer-in-charge.
S&F 3 module PVC Flush Box including white cover plate with frame for fixing of modular switeches/sockets etc. complete all as specified and directed by Engineer-in-charge.
S&F 6 module PVC Flush Box including white cover plate with frame for fixing of modular switeches/sockets etc. complete all as specified and directed by Engineer-in-charge.
S&F 8 module PVC Flush Box including white cover plate with frame for fixing of modular switeches/sockets etc. complete all as specified and directed by Engineer-in-charge.
S&F LED Tube light fitting 18/20 watt 4 feet thermoplastic body 270 degree wide distribution CCT 6500 K including fitting fixed on wall/ceiling and connecting up complete with 2 core flexible cable white of size 23/0.0076 including taking down old unsv tube light fitting and making necessary connection complete all as specified and directed by Engr-in-Charge.
S&F LED Tube light fitting 9/10 watt 2 feet thermoplastic body including fitting fixed on wall/ceiling and connecting up complete with 2 core flexible cable white of size 23/0.0076 including taking down old unsv tube light fitting and making necessary connection complete all as specified and directed by Engr-in-Charge.
S&F PVC/polycarbonate Angular lamp Holder insulated body with back plate angle type suitable for batten complete all as specified and directed.
S&F Angle type holder insulated body in white colour with back plate suitable for batten fittings.as fixed in repairs all as specified and directed.
S&F LED glass tube rod T8 type, 4 feet long, with inbuilt driver and efficacy of 100 lumens/W as fixed in repairs all as specified and directed.
S&F LED Blub 9 watt Self Ballasted Retrofit type lamp with PBT body shell and DC Diffuser CCT 6500 K with fitting complete all as specified and directed.
S&F 10 watt LED Bulk head fitting in engineering plastic housing with clear prismatic diffuser complete with all accessories and connecting up with 3 core flexible cable white of size 23/0.0076 including taking down old unsv fitting and making necessary connection complete all as specified and directed by Engr-in-Charge.
S&F LED Tube light fitting 5 watt 1 feet pre coated CRCA body heavy duty Industrial Batten including LED tube rod 5 watt self ballasted lamps with thermoplastic body 270 degree wide distribution, output lumen 450lm , including fitting fixed on wall/ceiling and connecting up complete with 2 core flexible cable white of size 23/0.0076 including taking down old unsv light fitting and making necessary connection complete all as specified and directed by Engr-in-Charge.
S&F Aesthetically designed 1x1 Feet LED light 12 W flat panel round/square type for surface mounting which provides soft-light and glare free symmetrical illumination, including taking down old unsv light fitting complete all as specified and directed by Engr-in-Charge. .
S&F 36 Watt LED fitting back lit panel having white polycarbonate body & aluminium plate heat sink, high quality PMMA and HPF driver suitable for armstrong/grid ceiling,fixture size 595x595 mm,powder coated aluminium extruded housing including LED driver and lamp and fixing in recess ceiling with suitable size of aluminium strip as required for fixing of LED fitting with all accessories prewired and connecting up with 2 core twisted flexible copper conductor cable of size 23/0.0076 including taking down old unserviceable fitting complete all as specified and directed.
S&F LED building security light fitting 25W new generation energy saving and environmental friendly long life LED street light made up of pressure diecast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP65 protection and impact resistance of IK07 incl mounting bracket of suitable size and connection including taking down old unsv security light fitting complete all as specified and directed.
M&L Providing sub main wiring with two single core 6.00 Sqmm (nominal area) PVC Insulated FRLSH unsheathed multi stranded copper conductor cable 1100 volts grade drawing through PVC casing-capping/ PVC Conduit complete as per direction including 6.00 Sqmm PVC insulated unsheathed multi stranded FRLSH single core copper conductor cable for earth wire including taking down/removing old one and making good distrubed surfaces of walls, floors, etc complete all as specified and directed. Note : (i) Three runs of single core 6.00 Sqmm multi stranded copper cable and one run of casing caping/conduit shall be measured as one run length (ii) Extra length of cable required for connection to DBs/MCBs shall deem to be included in unit rate quoted by contractor against the item (iii) Earth wire run inside the casing capping/conduit.
M&L Providing sub main wiring with two single core 4.00 Sqmm (nominal area) PVC Insulated FRLSH unsheathed multi stranded copper conductor cable 1100 volts grade drawing through PVC casing-capping/PVC Conduit as per direction complete including 4.00 Sqmm PVC insulated unsheathed multi stranded FRLSH single core copper conductor cable for earth wire including taking down/removing old one and making good distrubed surfaces of walls, floors, etc complete all as specified and directed. Note : (i) Three runs of single core 4.00 Sqmm multi stranded copper cable and one run of casing caping/ conduit shall be measured as one run length (ii) Extra length of cable required for connection to DBs/MCBs shall deem to be included in unit rate quoted by contractor against the item (iii) Earth wire run inside the casing capping/ conduit.
Taking down unserviceable main switches, DBs, bus bars chambers including all fittings and fixtures etc complete from existing main boards and removing from site all complete all as directed.
S&F Prewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amp rated copper bus bar 240 Volts 8 way (2 + 6 way) single pole and neutral link complete all as directed by Engineer-in-Charge.
S&F Prewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amp rated copper bus bar 240 Volts 4 way (2 + 2 way) single pole and neutral link complete all as directed.
S&F MCB single pole and neutral (SP&N) 25 to 32 Amp 240 volts 10 KA 'C' series with all incoming/outgoing connections with proper size lugs including taking down old unserviceable MCB SPN complete all as specified and directed.
S&F MCB single pole (SP) 6 to 32 Amp 240 Volts 10 KA 'C' series with all incoming/outgoing connection with proper size lugs including taking down old unserviceable MCB SP complete all as specified and directed.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one number single pole MCB 20 Amps , 240 Volts complete all as specified and as directed.
S&F Onload change over switch AC-23, 32 Amp four pole 415 Volt with side handle inbuilt sheet inclosure and taking out old unsv complete all as directed.
S&F PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, 1100 volt grade complete for 1.5 sqmm size as fixed in repairs complete all as specified and directed.
All as per item No 56 here-in-before but size 2.5 sqmm
S&F PVC rigid rectangular blocks, with back plate complete of sizes 10x10x4.5 cm. as fixed in repairs complete all as specified and directed.
All as per item No 58 here-in-before but size 17.5x10x4.5 cm
All as per item No 58 here-in-before but size 24.5x19.5x4.5 cm
S&F PVC insulated aluminium conductor 1100 volts grade heavy duty cable, served with inner sheathing of PVC tape and overall PVC sheathed flat for service connections twin core cable multistranded of size 10 Sqmm ISI marked as fixed in repair complete all as specified and directed.
S&F Eelectronic meters temper proof LCD display with polycarbonate cover 230 V, 10 - 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage, and KWH including taking out the unserviceable/burnt and deposit to MES Store Yard,complete all as specified and directed.
M&L Earthing complete with galvanized steel earth plate electrode 600 mm X 600 mm X 6 mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth lead wire 4 mm dia, (main earthing lead ) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES SSR Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1(using 20 mm graded stone aggregate) for earth pit and 40 mm thick pre-cast RCC cover in 1 : 2 : 4 type B1 (using 20 mm graded stone aggregate) with 3 Nos 8 mm dia TMT bars both ways and testing on completion,etc complete all as specified and directed by Engineer-in-Charge.
RIA CONSTRUCTION
ms singh construction
RC CONSTRUCTION
MAA COMMUNICATION
STANDARD ELECTRIC WINDERS
FREEZCON
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .