Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.8 LAccepted-Finance | L1 | Accepted-Finance ACCEPTED | |
| 2 | L2₹11.8 L+₹2 L (20.4%)Accepted-Finance SINGAMARI SINGTAM ROAD NORTH POINT DARJEELING WB | DARJEELING | DARJEELING | WEST BENGAL | L2 | Accepted-Finance ACCEPTED | |
| 3 | L3₹11.8 L+₹2.0 L (20.8%)Accepted-Finance | L3 | Accepted-Finance ACCEPTED | |
| 4 | L4₹12 L+₹2.2 L (22.4%)Accepted-Finance | L4 | Accepted-Finance ACCEPTED | |
| 5 | L5₹12.5 L+₹2.7 L (28.0%)Accepted-Finance GHOOM BHANJYANG GHOOM DIST DARJEELING WEST BENGAL | GHOOM | DARJEELING | WEST BENGAL | L5 | Accepted-Finance ACCEPTED |
Tender Value
Refer Docs
EMD Value
₹28,000
Closing Date
18 Jun 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
PRINCIPAL HMI DARJEELING
PRINCIPAL HMI DARJEELING
ADDITION / ALTERATION OF MI ROOM AT HMI DARJEELING
2021_HMI_331876_1
HMI/RNM/CDC/5/21-22
Open Tender
CIVIL WORKS
Item Rate
180 days
HMI DARJEELING
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
PRINCIPAL HMI
₹28,000
27 Aug 2021
28 May 2021
21 Jun 2021
28 May 2021
18 Jun 2021
28 May 2021
210 days
Amount
Supply fabricating and fixing of aluminium door powder coated of extrusion aluminium section including frame work complete, consisting of frame vertical and horizontal members, of size 104mmx44.45mmx1.8mm thick. Vertical style of door shutter of size 85mmx44.45mmx1.8mm thick. Top, middle and bottom rial of size 85mmx44.45x1.8mm thick and fixing 5 mm thick plain/tinted sheet glass of Modi guard/Atul or prelaminated particle board 9 to 10mm thick of make Kit Ply with aluminium bedding and rubber gasket/beading including frosted film as desired fixing of hydraulic floor spring one in single leaf or two nos in double leaf door of Make Sandhu/Kelvin/Evershine. One mortice lock for aluminium door (each) and two aluminium tower bolts for each door. Fixed with rawl plug including rectification of floor/wall to match the existing surfaces. All as specified and as directed by Engineer-in-Charge at site. (Cost of sheet glass/frosted film & sun control film shall be included in the unit of this item)
S&F for powder coated aluminium window three track sliding type with frames including 5mm thick tinted glass, stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm fixed with standard rubber gasket, aluminium beadings and joining cleat for fixing including locking devices complete all as specified. Make : Jindal aluminium sections Nos. 20671, 20672, 20690 & 20668
M&L for roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as directed by Campus Supdt.
M&L for screed bed or bedding layer of mortar 20 mm thick for laying floor finishes in CM 1:6 for laying of floor tiles as dierected.
M&L for 10 mm thick plaster in cement mortar 1 : 4 as a backing coat for fixing of wall tiles complete all as specified.
M&L for joint free light shade vitrified tiles 10 mm thick (square / rectangular) polished area of each tile exceeding 0.36 sqm but not exceeding 0.42 sqm in floors etc set & jointed in neat cement slurry and pointed with white or coloured cement to match complete. Make -Somany/Johnson/Orient
M&L for joint free Dark shade vitrified tiles 10 mm thick (square / rectangular) polished area of each tile exceeding 0.36 sqm but not exceeding 0.42 sqm in floors etc set & jointed in neat cement slurry and pointed with white or coloured cement to match complete. Make -Somany/Johnson/Orient
All as per items No 7 above but in vertical surfaces complete all as directed.
Taking down shutters exceeding 1 Sqm and not exceeding 2 Sqm each and refixing in same opening complete all as directed.
M&L for fixing of designer/decorative veneer sheet of size 1.5 to 2 mm thick on shutter with adhesive including removing of existing veneer complete all as specified and as directed.
M&L for preparation of old painted surfaces and applying one coat of synthetic enamel paint on wooden surfaces complete all as specified and as directed.
WALL PANELLING SCOPE OF WORK (i) Material and labour second class softwood plain fillets square rectangular/triangular section clean sawn and fixed with nails to existing wall of 30 cm centre to centre vertically and horizontally scantling required exceeding 13 sqcm but not exceeding 25 sqcm all as specified and directed. (ii) Material and labour 6mm thick plywood grade BWR, type BB fixed with nails to timber framework all as specified and directed. (iii) Fixing 3mm thick one side decorative veneered sheets with fevical over 6mm thick plywood with fixing of wooden beading for setting of veneered sheet. (Beading should be removed before polish) (iv) fixing of 2nd class softwood decorative beading to veneered for door/window jambs and cills and ceiling top where required. (v) Preparation of previously untreated veneered surfaces of any description over 10cm width or girth, applying one coat of colour mix putty over veneered nails, after drying of putty remove the putty by sand paper and finishing coat with PU finish with spary over two coat of sealer under coating complete all as specified.
Ditto all as per specified in Ser No 13 above but fixing 19mm thick plywood grade BWR type BB fixed with nails to timber framework of sectional area not less than 50sqcm to existing wall 30cm centre to centre.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) completete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, lights fitting etc remiving materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floor etc
Material and labour for point wiring with 1.5 Sqmm (Nominal Area) FRLS PVC insulated sheathed multi stranded copper conductor, 1100 volts drawn through and including rigid non metallic surface conduit medium grade ISI marked minimum 20mm dia and its accessories complete alongwith 1.5 Sqmm cable but in green colour as continuous earthing wire and connnecting to common earth duy completely concealed. Surface in walls/ceiling roofs with and including 1.2mm thick MS sheet terminal boxes duly fabricated flush mounting in the wall for mounting switches, switch socket combinations, fan regulators etc, as required with 3mm thick plastic laminated sheet top cover all as specified and directed for the following points.
(a) One light point controlled by one modular switch
(b) One three pin modular socket out let 5 Amp on independents board complete
Supply and fix modular switch 1 way 6 Amp, 240 Volt. Make : Anchor/Havells
Supply and fix modular switch 1 way 16 Amp, 240 Volt. Make : Anchor/Havells
Supply and fix round type LED 15 watt for ceiling light complete set all as directed. Make - Havells
Supply and installation of hospital 3 seater stainless steel waiting chair as per sample and complete all as directed.
Supply and fixing of Acrylic Medical LED Signage Board at outer wall surfaces complete all as specified and as directed by the Principal.
M/S KISHOR PRADHAN
GENIUS UNEMPLOYED ENGINEERS CO OPERATIVE SOCIETY LIMITED
MANOJ GURUNG
NIM DORJEE TAMANG
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .