executive engineer PWD RnB nobra
executive engineer PWD RnB nobra
FINISHING AND ELECTRICAL WORK OF ROOM ON PWD REST HOUSE TURTUK NUBRA
2022_PWD_7579_9
PWD RnB/N/111 2022-23
Open Tender
Civil Works - Others
Item Rate
30 days
Nubra
please read NIT
7 documents required · 7 mandatory
₹1,000
Payable To executive engineer PWD RnB nobra
₹31,600
Yes
26 Sept 2022
9 Sept 2022
17 Sept 2022
9 Sept 2022
16 Sept 2022
9 Sept 2022
Amount
P/F 8mm thick pre laminated wooden flooring (Green panal)HDF including 1.5mm thick form and wooden beading 50x12mm size.
Providing and fixing wooden paneling with 12mm board finish with9mm thick toung and grove wooden paneling and polish with walnut colour French spirit polish.
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge .1 Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes. Rectangular hollow section (50x25x2.60)mm
Electrical work Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit asrequired. A ) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
b ) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
c ) 2 x10sq. mm + 1X 6 sq. mm earth wire
d ) 4X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excludin modular plate etc. as required. a) 5/6 A switch
3 pin 5/6 A socket outlet
Telephone socket outlet
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction boxwooden block including connections etc. as required
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 No.s 3 pin 5/6 A modular socket outlet and 2 No.s 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a ) 6 way (4 + 18), Double door
b ) 8 way (4 + 24), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. A ) Single pole 6 /16 amp
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a ) 25mm
Supply, installation , testing & commissioning of GI Electrode Earthing with 84mm dia and 3 meter length , with 3mm thick the electrode should be hot dip galvinised . The GI Electrode shall be pre filled with cristaline Conductive Material ( CCM ) . The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact between the electrode and compound should be eco - friendly GI Electrode Earthing should be eco - friendly GI Electorde Earthing should be maintinance free and does not require regular manual addition of water . The earthing pit should be covered with PVC cover.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
100 A,30KA,FPMCCB
Change over switch 100 Amp MCCB Type FP
Fabrication, supplying , installation testing and commissioning of following pannel made out of 2mm thick M.S sheet , floor mounted , vermin & dust proof, indoors , duly painted with provsion for fixing of1 nos incomer MCCB, , MCCB type change over switch - 1 No including supply and fixing 2 set of Aluminium bus bar and strip for housing MCB,s 24 Nos , MF Digital Meter and other allied accessories as required ( Make as per annexure)
Supplying and fixing of following rating 240 /415 Volt " C" series miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connection , testing and commissioning.( Above to 32 Amp) a ) SPN 63 Amp
TPN 63 Amp
Supplying and fixing of 120 watt LED Street Light complete with GI pipe bracket duly embeded along the parapet /wall. Wipro LR02-132-XXX-57-G2 or equivalent approved make
Supplying & fixing following luminaries as required LL20-111-XXX-65NE3 wipro 10 watt LED tube light fitting. equivalent make and model Philips/Crompton Greaves.
20 watt LED tube light fitting. LL20-221-XXX-65NE3 of wipro or equivalent make and model Philips/Crompton Greaves.
Supplying, installation testing and commissioning of LED 2'x2' recess mounted fixture that delivers atleast 3000 lumens and wattage not more than 36 watt. The luminaries shall have a CRC a power coated body and a high efficiency diffuser. WIPRO CRCO10 RO 38HP57GL OR equivalent approved make.
Supplying and fixing of Angle / Baten Holder with 9 watt LED Lamp polycarbonate including making complete connections etc. as required. ( Make as per annexure enclosed.)
Supplying and fixing of following electrical items suitable for operating on 240 /230 volts AC, 50 HZ supply , including connection etc. as required. Exhaust fan 300 mm size ( Heavy duty) CG transair or equivalent approved make
250 mm Shutter Type
M/S MOHD SASDI
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .