Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.8 LAccepted-AOC HOUSE NO 03 RAGHAVPURAM MALL ROAD MORAR GWALIOR | GWALIOR | GWALIOR | MADHYA PRADESH | L1 | Accepted-AOC Being a lowest | |
| 2 | L2₹39.8 L+₹2.3 L (6.17%)Rejected-Finance G 124 FLAT NO 4 DILSHAD COLONY DELHI 110095 | SHAHDARA | DELHI | 110095 | L2 | Rejected-Finance Not a lowest tender |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
19 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF TA Gwalior
GE AF TA Gwalior 474020
REPAIR/MAINT OF STORAGE AREA, ORP, BLAST PENS AREA AND E/M INSTALLATION IN TECH AREA AT AF STN GWALIOR
2023_MES_591694_2
8900/1470/GWL/E8
Open Tender
Civil Works
Item Rate
330 days
AF STN Gwalior
As per tender documents
8 documents required · 8 mandatory
₹500
GE AF TA Gwalior
₹90,000
Yes
14 Jul 2023
2 Jun 2023
21 Jun 2023
2 Jun 2023
19 Jun 2023
5 Jun 2023
Amount
Surface dressing n exc 15 cm deep of filled earth over ORP and Blast pan & treverse walls all as directed by Engr-in-Charge
S&F in repairs HDPE perforated GEO CELL mesh for slope protection of earth any shape with size (330-100mm) 1.50mm thick fixed to earth with necessary arrangements 'J' hooks & jointing clips including levelling & ramming earth to required gradient by using the existing traverse earth complete all as specified and directed. Make: Terrain Infratech, Geogical Structial Infra Pvt Ltd, Omega Construction as approved by GE.
Rough excavation by mechenical means not exceeding 1.50 m deep and getting out in soft/loose soil.
Removing excavated material exc. 1.50Km and upto total distance of 5 km and depositing where directed at a level n exc. 1.5 m above the starting point.
Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick and finishing to required size, shape, etc. up to a height of 4.50 mtr high from base complete all as specified and directed.
All as per item No 5 but exc 4.50m height and up to to 8.5mtr .
M&L for PCC 1:3:6 Type B1 (using 20mm graded Stone aggregate) as in edges traverse wall and geocell, floor, plinth finished even & smooth complete all as specified and directed.
Removing existing earth/soil laid over ORP and kept aside for refilling the same at its position, levelling and well raming after completing roof treatment work all as direted by Engr-in-Charge.
M&L for Raised pointing to random or polygonal rubble, uncoursed or brought upto courses including Raking out joints/ pointing to random rubble or polygonal rubble uncoursed or brought up to courses etc.
Demolition of cement concrete ( unreinforced) in Roofs, floors (other than ground floors), tiles including existing roof treatment (screed plaster,& tarfelt of any description) and removing to a distance exc. 500 m and n.exc. 5 Km from site complete all as specified and directed.
M&L for PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate as in benching, kerbs and levelling course etc as in floor and roof complete all as specified and as directed.
M & L for 10 mm thick screed bed in cement mortar 1:4 mixed with using liquid water proofing compound as per manufacturers instructions (Note: Water proofing compound shall be measured and paid seprerately under respective item of "BoQ") and applying APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) laid over hot blown bitumen grade 85/25 conforming to IS-702 @ 1.2 Kg/Sqm over primed surface with bituminous primer @ 0.30liters/Sqm surface by forced application complete all as specified. Make-IWL India Ltd, Torchtar, STP.
Supply only liquid water proofing compound complete all as specified and directed.
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar PCC 1:2:4 all as specified and directed.
M&L for Cement concrete tiles 25cm x 25cmx 20mm thick, machine pressed set jointed and pointed in neat cement slurry in roofs, over 15mm thick screed bed in CM 1:4 complete all as specified and directed.
Demollition of cement concrete ( unreinforced) including floor tile ground floors and pavings n. exc 15 cm thick below or above G.L complete all as specified and directed .
M&L for 25 mm thick PCC (1:2:4) type B0 (12.5 mm graded stone agg) as in sub base of flooring/tiling complete all as specified and directed.
M&L for 75 mm thick plain cement concrete (1:3:6) type B1, using 20 mm graded stone aggregate as in Plinth protection and finishing the surface even & smooth with using extra cement complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.
M&L for glazed ceramic Coloured tiles in vertical surface 350x 250x 7mm/ 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick rendering on fair faces of brick work or concrete surface in cement moratar 1:4 complete all as specified and directed.
M&L for vitrified ceramic coloured tiles (square/ rectangular) 8-9mm thick area of each tile exc 0.18Sqm but not exc 0.38Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles over 15mm th screed bed in CM 1:6 complete all as specified and directed.
Demolition of stone slabs and interlocking tiles of any description or thickness in floors, aprons etc laid in any type of mortor complete all as specified and directed.
M&L for 15-18 mm thick Granite (of any type) work rounded and polisged at edges in floors, steps pillars, platform or oval shape wash hand basin including cutting to fit the WHB, partition and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over 20mm th screed bed in CM 1:6 complete all as specified and directed.
M&L for 15mm thick rendering fare face of brick/stone masonry walls in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed including taking down cement plaster on brick surface or stone including raking out joints hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for Preparation of newly plastered surface and applying a layer of wall putty to make the surface even and smooth and applying two coats of Exterior emulsion weater coat in camouflaging pattern on CCD scheme (Pattern as approved by User & GE) on surfaces of any type of building, wall, any surfaces, any height, incl preparation complete all as specified and directed.
M&L for Preparation of newly plaster surface of wall and applying two coat of distemper oil emulsion over a coat of primer and a coat of putty (preparatory to distempering) white or tinted as approved all as specified and directed.
S&F 5mm thick solid PVC wall Panneling/lining any colour wood grains printed PVC pre laminated sheet, one side including beadings at top, bottom, corners of door window jambs of matching colour Jambs over inclusive of solvent cement and fixing at site over PVC fillets including dismantling of existing wall paneling with fillets complete all as specified and directed. Note: PVC fillets shall be measured & paid under respective item of BOQ.
M & L in repair for 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC Frame complete all as specified and directed.
S&F in repairs 12mm thick acoustic mineral fibre micro perforated finish boards of approved pattern for fixinf to existing false ceiling GI grid complete all as directed. Make : GypRoc, Saint Gobain, Armstrong etc
S&F in repair 10 litre capacity PVC valve less symphonic action type flushing cistern low level , white, with inlet, ball valve, float and handle including brackets and Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern complete all as specified and directed.
S&F in repairs Vitreous China wash down water closet pan (pedestal pattern), P- Type/ S-Type any colour (excluding fixing bolts, flushing cistern and flush pipe) all as specified and directed. Make: Hindware, parryware & Cera etc
S&F in repairs PVC Seat cover for water closet pan (pedestal pattern), matching colour including fixing bolts. Make: Hindware, parryware & Cera etc
S&F in repair Vitreous China urinals half stall flat back white, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinals to plugs with and including 60mm long brass screws, pointing around urinal back in cement, including Brass CP waste coupling and with PVC waste pipe & Grating complete all as specfied and directed. Make: Hinware, parryware & Cera etc
S & F in repair vitreous china wash basin, white, flat back size 550 X 450mm including 32mm Brass CP waste Coupling, PVC Waste pipe and Grating complete all as specified and directed. Make: Hinware, Parryware & Cera etc
S&F 15mm bore medium grade galvanized iron tubing with all fittings e.g. socket, union, nipple etc. including cutting of pipe in required size , making threads etc. including taking down old unserviceable pipe, complete all as specified and directed
S&F 20mm bore medium grade galvanized iron tubing with all fittings e.g. socket, union, nipple etc. including cutting of pipe in required size , making threads etc. including taking down old unserviceable pipe, complete all as specified and directed
M&L for Cutting chases for concealed water tubing or concealed conduit wiring, etc. making good to facings where required and pointing in cement mortar 1:3 not exc 10 cm girth complete all as specified and directed.
S&F in repair for 110 mm bore PVC(SWR) pipes single socketed , in any length with rubber ring joints, laid in trenches ,floor or in wall complete all as specfied and directed.
S&F in repair for 75 mm bore PVC(SWR) pipes single socketed , in any length with rubber ring joints, laid in trenches ,floor or in wall complete all as specfied and directed.
S&F in repair 110mm PVC(SWR) bends complete all as specfied and directed.
S&F in repair 110mm PVC(SWR) junction single, (Single T) eual or unequal complete all specfied and directed.
S&F in repairs 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement.
S&F in repair for PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed.
S&F in repair chromium plated fency type bib taps long body cast copper alloy with capston head handle screwed down screwed for iron pipe or for brass ferrule & fixed in 15 mm bore pipe complete all as specified and directed. Make: Parryware, Marc, L&K, Prayag, Parko etc.
S&F in repair 15mm bore pillar taps, fancy type, chromium plated screwed down high pressure with or without lettered with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified and directed. Make: Parryware, Marc, L&K, Prayag, etc.
S&F in repairs Brass CP, fancy type 15mm bore Angle Cock with crutch or butterfly handle, screwed both ends for iron pipe. Make: Plumber, Parryware, Marc, L&K, Prayag, etc
S&F in repairs 15mm bore two way Angle Cock brass CP fancy type with crutch or butterfly handle, screwed both ends for iron pipe. Make: Plumber, Parryware, Marc, L&K, Prayag, etc
S&F in repairs CP Health faucet, fancy type with one metre ong houge pipe . Make: Plumber, Parryware, Marc, L&K, Prayag, etc
Dismantling of old PVC water tanks with float valve and S&F 500 lit capacity rotational moulded ploythylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position with 20mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 2 1 0 g m s) complete all as specified and directed.
M&L for complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers and and applying a coat with putty to make the surface even and smooth matching to the adjacent wall surfaces and applying two coats distemper oil emulsion, over a coat of primer with roller all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete.
S&F MS tubular pipes as in vertical post , rafter & purlins as in sheds/canopy cut to reqd shape , welding drilling and including bending as necessary , gusset plates, riveting , etc confirming to Fe-290 Gde-E-165 complete all as specified and as directed. Make: ISI Marked as approved by GE.
M&L for preparation of new or previously untreated surfaces of steel of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide primer complete all as specified and directed.
M&L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensilestrength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified including Dismentling of existing Plain or corrugated steel sheeting, any gauge, thickness complete all as specified and directed.
M&L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, Ridge, valley/ gutter fixed with self tapping screws including Dismentling of existing Plain or corrugated steel /AC Sheet complete all as specified and directed.
S&F in repairs powder coated aluminium door shutters with extruded built up standard tubular sections using aluminium sections not less than 2.00mm thick, (shutter with styles 85mmx44.45mm, top rails 83.5mmx44.45mm intermediate rail 83.5mmx44.45mm, bottom rail 114.3mmx44.5mm) fixing to frame including rubber neoprene gasket and aluminium beading, 02Nos 200mm handle, 01No 300mm long sliding door bolt and 01No 150mm tower bolt to each shutter using C.P./SS screws, complete all as specified and directed.
S&F 5mm thick tinted glass as in aluminium door/windows complete all as directed by Engr-in-Charge.
S&F 4mm thick ACP (Aluminium composit panels) as in aluminium door/windows complete all as directed by Engr-in-Charge.
Cutting existing kota stone floor over saucer drain without breaking and repair the edges with CM 1:4 including cleaning the coverd drain and laying existing kota stone over drain as covers all as directed by Engr-in-Charge.
S&F pre powder coated aluminium frame or shutter for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
Demollition of reinforced cement concrete (reinforced) of any description and in any position not otherwise specifically provided and dispose off the demolished material out of defence land complete all as specifeid and directed.
M&L for RCC nominal mix 1:2:4 type B1 (using 20 mm crushed stone aggt) as in shelves, slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and the likec complete all as specified and directed.
Formwork to soffits of suspended shelves, slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
S&F in repairs sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs,washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm x160mm including PTMT sink waste coupling and waste pipe complete all as specified and directed. Make Nirali, Prayag, AMCO Parryware etc
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick in CM (1:4) complete all as specified and directed incl demolition of brick work in any position built in cement mortar including complete all as specified and directed.
M&L for 15mm thick rendering fare face of brick/stone masonry walls in CM 1:4 finished even and smooth (without using exrtra cement) complete all as specified and directed.
M&L for Preparation of newly plaster surface of wall and applying two coat of distemper oil emulsion over a coat of calk whiening (preparatory to distempering) white or tinted as approved all as specified and directed.
M&L for Preparation of old decorated surfaces of ceiling including cornices, by brooming down or steel wire brushing to remove dust, dirt and loose scales of lime wash and other foreign material, scrapping down, smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots etc including filling the cracks and depressions with putty and applying one coat of white wash complete all as specified and directed.
M&L for Preparation of old decorated surface of wall include brooming down with steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots, including filling the cracks and depressions with putty and applying one coat of distemper oil emulsion with roller white or tinted as approved complete all as specified and directed.
M&L for Complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers or any other means, and filling the cracks /depressions with wall putty/white cement to make the surface even and smooth matching to the adjoining surface and applying two coats of Exterior emulsion weater coat in camouflaging pattern on CCD scheme (Pattern as approved by User & GE) on surfaces of any type of building, wall, any surfaces, any height, incl preparation complete all as specified and directed.
Supply, Laying & connecting stranded aluminum conductor, screened, XLPE insulated, armoured shielded and PVC sheathed cable of following sizes conforming to IS 7098 (Part-I) amended upto date complete all as specified and directed for the follwoing sizes:- (a) 6 Sqmm 4 Core Make : Havells/Polycab/Plaza Note :- (i). Lugs/Glands/saddles of suitable size required for fixing of cables in panels/junction boxes /on walls shall be included in the item rate. (ii) Cable path indicators shall be provided at every 50 mtr intervals of the cable is deemed to included in the item rate.
(b) 10 Sqmm 4 Core
(c ) 16 Sqmm 4 Core
M&L for boring under roads, paths with 40/50 mm dia HDPE pipe fpr passing of cables complete all as specified and as directed. Note: HDPE pipe is included in the quoted rate
Excavation in trenches in soft loose soil not exceeding 1.5 m deep and not exceeding 1.5 m width and getting out including forming bottom surface for laying cables/pipes all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n exc 25 cm thick after the cables are laid, jointed & tested complete all as specified and directed
Removing of surplus excavated soil not exceeding 50 M distance and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
Supply and spreading clean, dry, fine river sand for UG electric cable in two layers (8 cm thick before laying the cable & 15 cm thick after laying cable) total 23 cm thick including gentle punning the sand upto 18 cm (total thickness) and consolidated around cable for protection of under ground cable complete all as specified and directed. (Note :- Only punned thickness shall be measured for payment).
Supply & Laying precast PCC cable concrete cable cover LV low voltage type -I flat ISI marked of size 250 mm x 150 mm x 40 mm complete all as specified and directed by Engr-in-charge. Make :- Mahatab/Ravi/Duracoat
Supply, fixing, connecting and testing in replacement integral LED flood light luminaries, 100 watts at any height ranging from 3m to 16m, with scondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP66 with mounting bracket and all accessories and connecting the same to electric source with using copper conductor 1.5 Sq mm PVC insulated flexible three core cable , including all accessories and fixing the light fitting to walls/ ceiling etc complete all as specified and directed. Make :- JJETAQUANTOPLUSFLP30WLED757SYSMLENS/Philips/Oshram
All as per above item but 90 Watt complete all as specified and as directed
S&F in repairs recess mounting LED panel 12 W 160mm X 160mm luminaire white powder coated CRCA housing with LEDs seamless front frame with flat white high transmission acrylic cover.Make: Bajaj LED Squadra 12 W of Bajaj or eqvt in Wipro/CG
Taking down carefully earth strip alumium of any size and any type from any height (3m to 16 m) of building or hangar ( roof conductor and down conductor) of Lightning protection and refixing the same with necessary insulators complete all as specified and as directed.
All as per above item but Air Termination rod of any size
Taking down carefully any light fitting from ceiling/wall and refixing the same along with necessary wires and fittings complete all as specified and as directed
All as per above item but Celing fan of any make and capacity
Dismantling and taking down the serviceable Air Conditioner of 1.5/2/3 TR indoor and out door unit with voltage stabilizer and refixing the same at directed location complete all as specied and as directed. Note: 1. Proper pumping down of refrigirant is the responsiblity of the contractor. Any topping up of refrigirant gas required is included in the quoted rate, 2. Necessary insulation required for copper pipe is included in the quoted rate.
Taking down carefully aluminum /copper point wiring (light, fan, switch & power) complete including fittings such as switches, ceiling rose, pendent, by unscrewing from board ,out let box, fitting and fixture such as bulk head fitting, sketch fittings and making good the disturbed rurfaces of walls floors etc all as directed.
M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits),with multi stranded copper conductor 1.5 sq mm nominal cross sectional area, single core, pvc insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked with valid CML No in and including medium grade, PVC Concealed conduit of dia not less than 20mm and conduit accessories concealed in wall, ISI marked with valid CML No (IS-9537-1983 for conduits and IS: 3419:1976 for conduit accessories), with mild steel/pressed steel sunken boxes (with earth duly) duly painted with two coats of anticorrosive paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3mm thick hylam laminated sheet cover for fixing of switches, sockets etc including PVC insulated multi stranded copper conductor 1.5 sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dully complete all as specified and directed at site for the following : (a) One light/ Fan point controlled by one way switch.
(b ) One 5 Amps switch socket combination on independent board.
(c) One 5 Amps socket on same board with other switches.
All as per item No-92 here in above but 2.5 Sqmm stranded copper conductor and independent board for 15 Amps switch/ socket point as directed.
M&L for point wiring with stranded copper conductor 1.5. Sqmm 1100 Volts grade FRLS PVC insulated and unsheathed including ISI marked PVC casing capping of required sizes as indicated including all accessories, copper conductor cable 1.5 Sqmm insulated and unsheathed PVC cables as earth wire, trminal boxes closed recossed type. PVC Plastic board all as required as specified and directed for the following :- (a) One light/ Fan point controlled by one way switch. (Make : Havells/Finolex/Polycab)
(b ) One 5 Amps switch socket combination on independent board.
(c) One 5 Amps socket on same board with other switches.
All as per item No-96 here in above but 2.5 Sqmm stranded copper conductor and independent board for 15 Amps switch/ socket point as directed.
S&F in repairs switch piano flush type single pole one way 5 Amps 230 V.
S&F in repairs switch socket out let 3 pin 5 Amps flush type 230 Volts multipurpose,
All as per item No-101 above but 5 Amps and 15 Amps multipurpose( 3 Pin 15 Amps and one pin 5 Amps controlled by one switch.) .
S&F in repairs fan regulator Electronic Step type (min 5 steps) 2module, 100W ISI marked by removing old u/s resistance type fan regulator including necessary connection in existing laminated switch board by making necessary holes etc., complete all as specified and directed by Engineer-in-Charge.
Sunil Traders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .