| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹35.9 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹42.9 L+₹6.9 L (19.3%)Rejected-AOC | L-2 | Rejected-AOC L-2 | |
| 3 | L-3₹43.4 L+₹7.5 L (20.7%)Rejected-AOC OFFICE 4 9 SWARG ASHRAM NANAK RAM COLONY PARMANAND CHOWK DELHI 110009 | DELHI | DELHI | DELHI | 110009 | L-3 | Rejected-AOC L-3 | |
| 4 | L-4₹45.4 L+₹9.5 L (26.3%)Rejected-AOC | L-4 | Rejected-AOC L-4 | |
| 5 | L-5₹48.5 L+₹12.5 L (34.7%)Rejected-AOC C O PRAMOD KUMAR SHAH BUS STAND NANDPRAYAG NANDPRAYAG CHAMOLI UTTARAKHAND 246429 | NANDPRAYAG | CHAMOLI | UTTARAKHAND | 246429 | L-5 | Rejected-AOC L-5 |
Tender Value
Refer Docs
EMD Value
₹95,000
Closing Date
19 Feb 2022, 6:00 pmClosed
GE I RND Delhi
MILITARY ENGINEER SERVICE, GARRISON ENGINEER I RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
PROVISION OF B/R AND E/M WORK AROUND T-72 NEW WET CANTEEN, STORE ROOM, ALUMINIUM PARTITION AND GARBAGE PIT IN CFEES, SSPL, INMAS UNDER GE I RND DELHI
2022_MES_501249_2
GE/RND-95/DLI/2021-2022
Open Tender
Civil Works
Item Rate
180 days
Delhi
Class- D, Cat a(i)
2 documents required · 2 mandatory
₹500
Yes
GE I RND DELHI
₹95,000
Yes
2 Mar 2022
31 Jan 2022
21 Feb 2022
31 Jan 2022
19 Feb 2022
7 Feb 2022
Amount
Demolition of brick work or stone masonry built in cement mortar including all quoins, pillars, arches etc.complete all as specified and directed
Excavation in trenches not exceeding 1.50 mtr wide and not exceeding 1.50 mtr depth for foundations etc or for column footings, manholes etc and getting out in soft / loose soil etc complete all as specified and directed
M&L for PCC 1:4:8, type D-2 using 40 mm graded stone aggregates as in foundations, filling and mass concrete etc complete all as specified and directed
M&L for RCC M-25 Design Mix using 20 mm graded stone aggregates as in foundations including rafts, column footings, plinth beams, etc complete all as specified and directed
M&L for RCC M-25 Design Mix using 20 mm graded stone aggregates as in columns, pillars, piers, posts and struts etc complete all as specified and directed
M&L for RCC M-25 Design Mix using 20 mm graded stone aggregates as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed
M&L for precast RCC 1:2:4 type B1 using 20 mm graded stone aggregate as in landings, cover slab,chajjas etc.and similar articles with plain faces set in CM 1:6 complete all as specified and directed
Use and waste of formwork to sides of concrete foundations, column footings, plinth beams, and similar works, vertical or to batter for rough finished flat surfaces of concrete etc complete all as specified and directed
Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions, for square, rectangular or polygonal, rough finished surfaces of concrete etc complete all as specified and directed
Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc rough finished surface etc complete all as specified and directed
Use and waste of form work to soffits of suspended slabs flat surface of concrete finished rough surfaces of concrete not exceeding 200mm thick, complete all as specified and directed.
Use and waste of formwork to chullah hoods, chajjas, trough and similar items including edges finished rough surfaces of concrete complete all as specified and directed
M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and directed
All as per item Ser No 13 above but 5mm dia and over upto 10mm dia in stirrups, spacers, binders etc.
M&L for brick work with sub class 'b' brick, straight or curved on plan exc 6.0 mtr mean radius built in CM 1:6 complete all as specified and directed
M&L brick work with sub class'B' bricks,straight or curved on plan to any radius in half brick thick wall built in CM 1:4 complete all as specified and directed
M&L for granite tiles 18 to 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone laid over & including 20 mm thick cement screed bedding in CM 1:6 including cuttings and polishing complete all as specified and directed
Moulding or rounding, cutting and smooth finishing on edges of Granite tiles etc complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 Using 20 mm graded stone aggregates as in copings, bands inlcuding necessary use and waste of formwork complete all as specified and directed
M&L for rendering 15 mm thick in CM 1:4 on fair faces of brick work or concrete surface & finish the surface fair & even complete all as specified and directed
M&L for preparing newely plastered surface of wall and applying two coat of cement base paint over a coat of alkali resistant primer complete all as specified and directed
M&L for rendering 15 mm thick on brick wall or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed
M&L for preparing new plastered surfaces and applying two coats of plastic emulsion paint over a coat of primer including 2 mm thick wall care putty over prepared surfaces complete all as specified and directed
M&L for extra labour over rendering or plastering for work in isolated width such as sides of copings and similar work not exc 15 cm in width or girth including cutting to edges, all mitres and stopped ends etc complete all as specified and directed
M&L for 75mm thick PCC 1:3:6 type C-2 (40mm graded stone aggregate)as in sub base, Floors, Paving, plinth protection, finished even and rough complete all as specified and directed
M&L for 50 mm thick PCC 1:3:6 type C2 using 40mm graded stone aggregate as in flooring /path etc finished even and smooth without using extra cement complete all as specified and directed
M&L for Cement concrete type B-0, 1:2:4 12.5 graded aggregate 40 mm thick finishing even & smoth without using extra cement as in flooring complete all as specified and directed
M&L for toughned glass 10 mm thick as in hinged doors, partitions automatic doors and similar work including cutting to shape , drilling holes required complete all as specified and directed
M&L for vitrified ceramic tiles 10 mm thick, light shade, (Square/rectangular) polished, area of each tile not exceeding 0.36 sqm, in floors etc. set & jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles and laid over 15mm thick screed bed or bedding layer in CM (1:6) complete all as specified and directed
M&L for 150mm thick (Compacted thickness) Wet Mix Macadam (WMM) (in two layers each layer of 75 mm thcik compacted) with crushed stone aggregate of specified grade, spread using mechanical paver as specified, rolled & consolidated as specified to required gradient and camber complete all as specified and as directed.
M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed
M&L for sand filling under floors in foundation including watering and consolidation complete all as specified and directed.
M&L for 400 micron thick polthylene sheet laid on sand layer complete all as specified and directed (sand layer measured and paid separately)
M&L for cement concrete work in pavement / hard standing of flexural strength 40 kg/ square centimeter in field using not less than 400 kg of cement per cubic meter thickness of concrete 25 cm or less and not less than 150mm layer in bays and compacted with using vaccum dewatering system plant, floating operation with power floater, finishing the top surface of concrete with power trowel and finally top surface shall be finished by brooming including necessary formwork to sides and edges of concrete complete all as specified and directed. Note:- The work shall be only be executed after approval of design mix by GE I
M&L forming contraction (Dummy joints) 65mm deep x 10mm wide, filled with sealing compound grade 'A' complete all as specified and directed
M&L forming 12mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade `B' complete all as specified and directed
M&L forming construction joints 30mm deep x 10 mm wide filled with sealing compound grade 'B' complete all as specified and directed
BLANK
S&F Anodised aluminium snap grid frame work for false ceiling and Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified and directed
S&F Exposed metal frame ceiling with 6mm thick calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid complete all as specified and directed Note:- Frame work shall be measured and paid seperately.
S&F aluminium powder coated section of size 63.50x38.10x1.60mm thick as in frame for aluminium door shutter fixed to walls etc with rawl plugs and steel screws incl all cuttings etc for fixing pivots complete all as specified and directed
BLANK
S&F aluminium powder coated, aluminum window and ventilator shutters, (minimum thickness of powder coating 50 micron), fixed type without sash bars, aluminium section weighing not less than 0.55 Kg/ Sqm including necessary jointing cleats, glazing clips, rubber packing, aluminium snap beading, screws etc. complete all as specified and directed.
S&F aluminium powder coated glazed and panelled fixed partition and fixed glazing and made out of aluminium section 63.50X38.10X1.60mm including necessary jointing cleats glazing clips rubber packing aluminium beading fixed to walls, floor with PVC rawl plug etc. complete all as specified and directed
S&F 12 mm thick particle board exterior grade prelaminated both sides fixed to aluminium shutters/partitions etc complete all as specified and directed
S&F 4.8 mm thick sheet glass ordinary quality/of any colour fixed by means of glazing pins and rubber beading etc in aluminium partitions etc complete all as specified and directed
S&F 2nd class hard wood plain, solid, straight, chowkat and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed
S&F 30mm thick flush shutters solid core construction, with block board core and both sides covered with decorative face veneer with lipping/frame to match complete all as specified and directed
S&F 100mm stainless steel butt hinges medium weight and fixed complete all as specified and directed
S&F 150mm aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed
S&F 250mm aluminium alloy anodised sliding door bolt with hasp staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed complete all as specified and directed
S&F 150mm size aluminium handles, cast type anodised complete all as specified and directed
M&L for cutting existing steel tubing of 25mm bore for alterations or additions (Each cut measured ) screwing existing steel tubing for alterations or additions (or lengthening screw on pipe to form connector) complete all as specified and directed
M&L for 15 mm bore GI tube , medium grade ,with all fittings, fixed complete to wall or laid in floors complete all as specified and directed
M&l for 20 mm bore GI tube , medium grade ,with all fittings, fixed complete to wall or laid in floors complete all as specified and directed
M&L for 25 mm bore GI tube , medium grade ,with all fittings, fixed complete to wall or laid in floors complete all as specified and directed
S&F rotational moulded polyethylene water storage tank triple layered of 1000 Ltrs capacity (cylindrical) vertical with (closed top) hoisted and fixed in position complete all as specified and directed
S&F Gun-metal gate valves, with iron wheel head, screwed both ends for GI pipe 20 mm bore and fixed complete all as specified and directed.
S&F vitreous China wash basin, white flat back, size 550x400mm including mild steel angle iron 40x40x6mm brackets cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed
S&F for mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to Fe 410 W (Gde E-250 ) quanlity B complete all as specified and directed
S&F structural steel plates (plain or chequered) channels, square cut or notched (ordinary or counter sunk) forming holes including round headed screws, clout nails or rivets and fixed to wood or steel framing riveted or welded as required and confirming to Fe-410-W (Gde E- 250) quanlity B complete all as specified and directed
S&F for structural steel work in tubular trusses medium grade including special shaped washer etc. (Post height appx 4 to 5 m) complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240, complete all as specified and directed
M&L for Preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer,complete all as specified and directed
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
M&L for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor with suitable arrangement complete all as specified and directed
S&F direction sign board of any size with 3 mm thick aluminium composite panel comprising both side high intensity prismatic grade retroreflecting sheeting as base and with cut out message (legends borders letters/numerals etc) as directed with high intensity prismatic grade retro reflective sheeting both side of boards with epoxy powder coating, complete all as specified and directed with the following specification :- (i) Paper used for printing should be 170 GSM 3M reflective vinyl. (ii) Printing of letter with mutoh eco solvent printer. (iii) Base of material used should be 3mm thick ACP.
Excavating in post holes (or similar holes) in any type of soil each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed
Returning filling in with soil , inlcuidng spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed
Removing excavated soil to a distance exc 1.50 Km but not exceeding 5.00 KM and depositing where directed at a level not exc. 1.5 m complete all as specified and directed
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
S&F structural steel roof trusses trussed purlins crane gantrie rails and fastenings and heavy bracket( Beam tee angle channel or flat sectins) including distance pieces cleats etc. in Fe410-W (Gde-E - 250) quality A complete all as specified and directed
M&L for 40 mm thick Damp proof course in cement concrete 1:2:4 type B-0 to horizontal or vertical surfaces including necessary formwork complete all as specified and directed
M&L for Glazed ceramic tiles in vertical surface size 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry over and including 10 mm thick rendering in CM 1:4 and pointed in white or colour cement to match the shade of tiles complete all as specified and directed
M&L for hard core, broken stone/boulders to gauge n exc 63 mm complete all as specified and directed
M&L for 100 mm thick PCC 1:4:8 type D2 (40mm graded stone aggregate) as in subbase of floor complete all as specified and directed
M&L for kota stone slabs, machine cut 20 to 25mm thick, set and jointed in neat cement slurry and pointed in cement slurry to match including rubbing and polishing complete, as in floors, laid over and including 20mm thick screed bed in cement mortar 1:6, over and incl 25 mm thick PCC type B-1 1:2:4 using 20mm graded stone aggregate and complete all as specified and directed
M&L for RCC Design mix M-25 as in chajjas complete all as specified and directed
M&L for RCC Design mix M-25 as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed
M&L for preparation of newly plastered surfaces of wall and applying two coats oil bound distemper over a coat of 2 mm thick wall care putty complete all as specified and directed.
M&L for 75 mm thick Cement concrete type C- 2, 1:3:6 (40mm graded stone aggregate ) as in Plinth Protection/Sub base etc complete all as specified and directed.
S&F factory made steel window with side hung shutters incl box type hinges with steel handle and steel peg stay complete with glazing bars devotailed or welded complete all as specified and directed
S&F Mild steel framed work such as grills, gratings,etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar; barred iron doors; ladder; framed balusters; railing; frame work for water tanks and similar work conforming to Fe 410-0 or Fe 310-0, complete all as specified and directed
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 Sqm in each pane complete all as specified and directed
S&F 50 micron thick powder coated aluminium section swing door shutters partly panelled and partly glazed comprising top rail 85.00mmX44.45mmX2.70mm, bottom rail 150mmX44.45mmX2.20mm, lock rail 150X44.45mmX3.00mm and styles 47.62mmX44.45mmX1.62mm and including jointing cleats,aluminium snap beading, rubber gasket glazing clips and two Nos disc type handles and one nos aluminium tower bolt 200mm long for each leaf on one side and 01 no 6 lever dead lock of brass for each leaf fixed in position complete all as specified and directed
S&F double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box main body with stainless steel cover governing pivot made of brass other parts made of mild steel heavy duty and fixed complete all as specified and directed
BLANK
Excavation over areas, n exc 1.5m deep and getting out in soft/loose soil complete all as specified and directed.
M&L for 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed
M&L for factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed
M&L for preparation of new plastered or concrete surface over 10cm girth and width and apply two coat of synthetic enamel paint over a coat of primer complete all as specified and directed
M&L for point wiring for one light/ceiling fan controlled by one switch with 1.5 sqmm nominal area PVC insulated and PVC unsheathed multi stranded copper conductor cable FRLSH including concealed PVC conduit 20 mm dia medium duty ISI marked including, suitable new GI 2mm thick sunken boxes, modular frame and cover plate for fixing of modular switches as per required point in that board, flush to surface including PVC insulated unsheathed 1.5 sqmm copper conductor cable FRLSH connected to common earth duly complete including cutting, chasing the surface and then making good the same in CM 1:6 complete all as specified and directed.
All as per item No 92 above but for one socket 3 pin 5 Amp on same board
All as per item No 92 above but for one socket point out let 3 pin 5 Amp in independent board.
All as per item No 92 above but for one socket point out let 3 pin 15 Amp with 2.5 sqmm PVC copper conductor and 2.5 sqmm PVC insulated copper conductor as earth continuity conductor.
S&F modular switch flush 5/6 Amps 230V AC one way complete all as specified and directed
S&F one switch and one socket modular type 5 PIN 5 Amp 230 Volts AC complete all as specified and directed
S&F one switch and one socket modular type 3 PIN 15 Amp 230 Volts AC complete all as specified and directed
S&F regulator for ceiling fan modular electronic step type 120watt- 2module suitable for 1200/1400mm ceiling fan complete all as specified and directed
S&F ceiling rose surface type bakelite 65x50mm two to three terminal 230V complete all as specified and directed.
S&F telephone socket jack With shutter RJ 11 complete all as specified and directed
S&F LAN socket jack With shutter RJ 45 complete all as specified and directed
S&F sheet metal enclosure, single pole and neutral with two pin and earth plug and socket complete with one single pole MCB SP,C Curve type of capacity 25 Amp, 10 kA complete all as specified and directed.
S&F Triple pole and earth enclosure with three pin and earth plug with socket complete (Industrial type DB) with and including one MCB TP, C Curve type of capacity 63 Amp, 10 kA , 415 volt complete all as specified and directed.
M&L for submain wiring along with earth wire with the 4x6 sqmm+2x6 sq mm earth wire of FRLSH PVC insulated copper conductor single core cable in and including PVC conduit 25 mm dia medium grade with all accessories complete all as required or complete all as specified and directed. Note:- 6 run of 6sqmm cable and one run of PVC conduit shall be measured one unit.
M&L for submain wiring along with earth wire with the 2x4.OO sqmm+ 1x 4 sq mm earth wire of FR LSH PVC insulated copper conductor single core cable in and including conduit pipe 25 mm external dia medium grade including all accessories complete all as required or complete all as specified and directed. Note :- 3 run of 4 sqmm cable and one run of PVC conduit shall be measured one unit.
S&F light fitting 2'x2',36 watts recessed mounted pressure die cast aluminium luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation and separate replaceable electronic driver complete all as specified and directed.
S&F surface and wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver.trica batten 230 volt, 50 Hz, 20 watt and cable for connecting to ceiling rose complete all as specified and directed.
S&F LED flood light fitting with pressure die cast aluminium housing , complete with all accessories of 200W complete all as specified and directed.
S&F powder coated pressure die cast aluminium SMD LED street light for building security light with heat resistant toughened glass of capacity 45 Watt complete all as specified and directed.
S&F GI bracket made of 40 mm bore medium grade GI pipe bend to shape approx 1.2 m length incl clamp nut, bolts etc complete for fixing of street light on wall/ building complete all as specified and directed.
S&F ceiling fan, AC single phase 230/240 volt of size 1200mm sweep, 5 star rated with all accesories as capacitor, fan blade complete and connecting up with flexible copper wire twin core in a suitable length complete all as specified and directed.
S&F MCB distribution board double door vertical type made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating, VTPN 8 way. 415 volts with bus bar rating 200 Amps, dust and vermin proof and IP 42 - IK 09 protection suitable for incorporation of MCB, including grouting in the wall, cutting & chasing etc complete all as specified and directed.
S&F MCB distribution board double door vertical type made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating, VTPN 4 way. 415 volts with bus bar rating 200 Amps, dust and vermin proof and IP 42 - IK 09 protection suitable for incorporation of MCB, including grouting in the wall, cutting & chasing etc complete all as specified and directed.
S&F MCCB, 415 volts, four pole of cap 250 Amps, 36 KA, with Thermal - Magnetic Release, including spreader terminals / thimble of suitable size and making connections to fix in the existing panel complete all as specified and directed.
S&F MCCB, 415 volts, four pole of cap 125 Amps, 25 KA, with Thermal - Magnetic Release, including spreader terminals / thimble of suitable size and making connections complete all as specified and directed.
S&F MCCB, 415 volts, four pole of cap 100 Amps, 25 KA, with Thermal - Magnetic Release, including spreader terminals / thimble of suitable size and making connections complete all as specified and directed.
S&F MCB, C Curve type suitable for 415 volts AC supply, TPN with over load and short circuit protection and rupturing capacity not less than 10 KA and 63 Amps capacity complete all as specified and directed.
S&F MCB 6 Amp to 32 Amp SP 10 KA C' series complete all as specified and directed.
M&L in repairs Earthing complete with galvanished earth plate electrode of size 600 x 600 x 6.00 mm buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and galvanised iron or steel including earth work in any type of soil, GI funnel with GI mesh charcoal salt 15cm alternate layer and around the earth plate as shown in electrical plate no 3 of SSR Part I 2010, 20 mm dia watering pipe medium grade 1.70 mtr long GI protection pipe light grade 15mm dia from earth pit to main board & testing on completion:- (a) GI wire 4 mm dia (b) Watering pipe GI medium grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick in plaster cement mortar 1:6 including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel TMT bar 75mm centre to centre with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc as required 4 mm dia GI wire complete all as specified and directed
Supply and laying XLPE insulated armoured heavy duty electric cables with aluminium conductor,1100 volts grade, cross sectional area 185 Sqmm 3.5 Core complete all as specified and directed.
Supply and laying XLPE insulated armoured heavy duty electric cables with aluminium conductor,1100 volts grade, cross sectional area 70 Sqmm 3.5 Core complete all as specified and directed.
Supply and laying XLPE insulated armoured heavy duty electric cables with aluminium conductor,1100 volts grade, cross sectional area 10 Sqmm 4 Core complete all as specified and directed.
Supply and laying in trenches burnt brick sub class 'B' standard size for cable protection keeping width of the brick parallel to the length of the cable complete all as specified and directed.
Supply and spread clean dry river sand in trenches ,ducts including leveling, punning for cushioning of cables complete all as specified and directed. Note : Punned thickness of sand cushioning shall be measured
M&L for boring of holes under road, pavement, hard standing by trenchless techonology using ultra sound technique/mannually/mechanically and necessary machine including supply and laying of 100mm dia HDPE/GI pipe complete all as specified and directed.
Supply and laying of 100 mm dia GI pipe light grade ISI marked in ground road crossing of cable complete all as specified and directed.
M&L for earthing complete with galvanished earth plate electrode of size 600 x 600 x 6.00 mm buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanised iron earth strip 25 x 4mm as earthing lead by means of bolts, nuts, check nuts and galvanised iron or steel including earth work in any type of soil, GI funnel with GI mesh charcoal salt 15cm alternate layer and around the earth plate as shown in electrical plate no 3 of SSR Part I 2010, 20 mm dia watering pipe medium grade 1.70 mtr long GI protection pipe light grade 40mm dia from earth pit to main board & testing & on completion:- (a) GI earth strip 25x4mm (b) Watering pipe GI medium grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick in plaster cement mortar 1:6 including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel TMT bar 75mm centre to centre with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 25x4mm galvanised iron strip complete all as specified and directed.
Supply, install, commissioning and testing split type wall mounted Air conditioner of capacity 1.5 TR ( 4500K cal/hrs) single phase, Non inverter type suitable for 230 volt + 10%, 50Hz, AC supply complete with cordlss remote control unit, 5 star rating including suitable drain pipe as per site requirement complete with indoor and outdoor unit with copper condenser, standard length of refrigerant of copper pipe and PVC 3 core 2.5 sq mm copper conductor connection cable complete all as specified and directed. Note:- Half yearly servicing of AC upto 02 year ( checking refrigirent pressure, loose connection, leakage of refrigerant, top up of refrigerent if required and cleaning of PCB) will be provided by OEM and no extra amount will be paid on this account.
S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and directed.
S&F electrolyte grade copper tubing of size 1/4" suitable for any type of split type AC including synthetic rubber foam complete all as specified and directed. Note : - The quoted rate is inclusive of necessary T&P, Rope, Ladder etc with safety equipment for execution the work upto 2 stories building.
All as per ser item No. 134 above but size 1/2".
S&F PVC drain pipe in all respect complete with all necessary fitting such as elbow, tee, reducer etc with 9 mm thick nitrile rubber insulation of 25 mm dia complete as per site requirement, specified and directed.
BLANK
S&F single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 25 amps single pole and neutral with a two pin and earth plug and socket complete all as specified and directed.
S&F synthetic rubber foam for insulation for refrigerant copper piping of size 1/2" internal dia split type AC complete all as specified and directed. Note- The quoted rate is inclusive of necessary T&P, rope, ladder etc with safety equipment for execution the work complete all as specified and directed.
S&F synthetic rubber foam for insulation for refrigerant copper piping of size 1/4" internal dia split type AC complete all as specified and directed
Supply and installed of AC out door stand on the wall/roof with angle iron size 50x50x6 mm of suitable for outdoor 1.5 TR unit including one coat of primer and two coats of synthetic enamel paint and angle iron frame should be cutting, welding and grouting in the wall complete all as specified and directed
BLANK
BLANK
BLANK
M&L for one point wiring of PVC insulated FR LSH unsheathed copper conductor cable size 4.00 sqmm including earth wire of size 4.00 Sqmm in concealed PVC conduit including metal Flush sheet and modular Inner/Outer cover with frame for 15 amps power point including cutting chases for conduit where required and making good to wall and ceiling complete all as specified and directed
M&L for submain wiring alongwith earth wire of FR PVC insulated copper conductor, single core cable in surface/recessed of size 2x2.5 Sqmm + 1x2.5 Sqmm earth wire including suitable size of PVC conduit and lugs/thimble with nuts bolts and washers etc complete all as specified and directed.
S&F modular socket 6A 2/3 pin combined 2 module complete all as specified and directed.
BLANK
S&F of modular switch single pole one way 16/20 Amp , 1 Module complete all as specified and directed.
S&F for modular socket 6A/16 amp- 2/3 pin combained 2 module complete all as specified and directed.
S&F in LED light fitting 1x20 W, 220 V, AC decorative box type with driver holder including LED tube connecenting up with 3 core flexible copper conductor cable of suitable size from ceiling rose to connector complete all as specified and directed.
BLANK
BLANK
BLANK
S&F VTPN DB 4 Way vertical types suitable for MCCB income up to 100 Amps single door complete all as specified and directed.
BLANK
S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep Min air delivery 210 CFM with services value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
S&F exhaust fan steel body AC single body AC single Phase. 230 V of size 300 mm sweep with blades and frame and GI louvers complete all as specified and directed.
Supply and laying in existing duct XLPE insulated heavy duty electric cables with aluminium conductor,1100 volts grade, cross sectional area 25 Sqmm 4 Core and testing complete all as specified and directed.
SAWARIYA ENGINEERS AND CONTRACTORS
M/s Himgiri construction
m/s Kailash Chander
M/S SANJAY AGARWAL
M/s Manish Contractor
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .