Office of the Ex. Eng. (E and M) M-2
Pocket-A, Dilshad Garden, Delhi-95
Supply, Installation, Testing and Commissioning of chlorine and Turbidity analysis meter at Bhagirathi BPS.
2024_DJB_254692_11
NIT No. 16 (23-24)
Open Tender
Miscellaneous Works
Works
60 days
Bhagirathi BPS.
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Ac No. 50448339804
₹30,800
7 Mar 2024
24 Feb 2024
1 Mar 2024
24 Feb 2024
1 Mar 2024
24 Feb 2024
SITC of chorine analyzer with reagent less free chlorine measurement (NO reagent required), Amperiometric technique wth Anode and cathode measurement is faster and reliable, response time is less than 30 sec, Non - corrosive MOC of sensor and Transmitter - Sensor MOC: PVC, Accuracy is +/- 5% of measured value which is better than full scale value, Dual point calibration - zero & span, Dual point calibration - zero & span, Display Resolution available up to 0.1/1 digit, sensor protection class is IP - 68, Transmitter protection class is IP - 66, Modbus RS - 485 output & relay contacts available, complete assembly is premounted on mounting plate including rotameter, Niddle valve and Tubing. Make: - Forbes Marshall / EIP/ EEW/ Any DJB approved make
SITC of Turbidity Analyzer with Auto cleaning facility provided with both sided swing wiper cleaning system, scratchproof sapphire glass to protect stector, single pore diaphragm makes clogging nearly mpossible, single point zero calibration using DM/ DI water, response time is less than 30sec, Accuracy is +/- 2% of measured value for turbidity & +/- 0 .01 for pH, Display resolution available up to 0.1/1 digit, Repeatability is +/- 2% of measured value for turbidity & _/- ).01 for pH, Sensor material is SS 316L, Sensor protection class is IP-68, transmitter protection class is IP-66, Modbus RS-485 output & relay contacts vailable. Complte assembly is premounted on mounting plate including Rotameter, Niddle valve and tubing. Make: - Forbes Marshall/ EIP/ EEW/ Any DJB approved make
NS INSTRUMENTS AND CONTROLS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .