| Sl No | Description | Qty | Unit | CHANDER SEKER ENTERPRISE L5 | Sri Ram Construction L1 | EXCEL ENGINEERING WORKS L3 | M/s K Moorthi L4 | M/s Shiva Engineering L2 | BR ENTERPRISES L2 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | De-watering & cleaning of septic tanks, soak well, manhole, sludge chamber etc. by pumping out sludge water manually or mechanically including cleaning of shrubs/bushes vegetation 2.50m around the septic tank , necessary cutting pit for sludge burying and making good to usable condition of the same complete all as specified and directed by Engineer in charge | 80 | Cum | 2,600 ₹2,08,000 Lowest | 5,500 ₹4,40,000 | 5,500 ₹4,40,000 | 2,650 ₹2,12,000 | 4,000 ₹3,20,000 | 4,000 ₹3,20,000 |
| 2.00 | Cleaning of sludges/silt from Nahani trap / floor trap including roding CI/PVC pipe from Nahani trap / floor trap to gully trap etc in position including removing of rubbish/sludge to a distance exc 250 m & n.exc 500 m complete all as specified and directed by Engineer in charge | 300 | Each | 425 ₹1,27,500 | 200 ₹60,000 Lowest | 280 ₹84,000 | 450 ₹1,35,000 | 220 ₹66,000 | 220 ₹66,000 |
| 3.00 | Cleaning the blockage in IWC, EWC, including roding CI/PVC pipe after opening the oval asses door of PVC/CI bend, branch pieces etc upto first MH and placing the existing oval access door in original position including removing the rubbish/sludge to a distance exc 250m & n.exc 500m complete all as specified and directed by Engineer in charge | 300 | Each | 425 ₹1,27,500 | 220 ₹66,000 Lowest | 260 ₹78,000 | 450 ₹1,35,000 | 220 ₹66,000 Lowest | 220 ₹66,000 Lowest |
| 4.00 | Systematicaly cleaning and desilting of pipe sewers of any type and dia upto 200 mm any depth by passing knots, bambboo, kamti and disc of required size, pumping out liquid waste/ sewage, plugging diverting the flow in the drain, if necessary and stacking the removed silt/ sludge in deposits as directed including taking precautionary measures such as safety belts, dry cells, torch for lighting in side the manholes and drain etc, sprinkling bleaching powder on the silt/ sludge removed to avoid bad smell and disposal of silt out side MD land complete all as specified and directed by Engineer in charge | 400 | RM | 425 ₹1,70,000 | 240 ₹96,000 | 250 ₹1,00,000 | 450 ₹1,80,000 | 210 ₹84,000 Lowest | 210 ₹84,000 Lowest |
| 5.00 | Cleaning of drains (open) by desilting , including getting out depth up to 15 cm average of all vegetation, foreign materials, silt etc from drain and removing the materials outside MOD land complete all as specified and directed by Engineer in charge | 50 | Sqm | 415 ₹20,750 | 210 ₹10,500 Lowest | 400 ₹20,000 | 425 ₹21,250 | 300 ₹15,000 | 300 ₹15,000 |
| 6.00 | Cleaning of drains by destiling mud, vegetation, debries waste materials deposits etc, cleaning/removing manually/mechanically up to a depth of 60 cm and removing the materials outside MOD land complete all as specified and directed by Engineer in charge | 50 | Sqm | 415 ₹20,750 | 210 ₹10,500 Lowest | 400 ₹20,000 | 425 ₹21,250 | 340 ₹17,000 | 340 ₹17,000 |
| 7.00 | Cleaning carefully (with fresh water) the blockage in CI / PVC Pipe 75mm dia pipe on walls & ensure all blockage perfectly cleared including necessary scafolding up to a height of 20.00M complete all as specified and directed by Engineer in charge | 120 | Rm | 415 ₹49,800 | 170 ₹20,400 | 250 ₹30,000 | 425 ₹51,000 | 150 ₹18,000 Lowest | 150 ₹18,000 Lowest |
| 8.00 | Cleaning carefully (with fresh water) the blockage in CI / PVC Pipe 110mm dia pipe on walls & ensure all blockage perfectly cleared including necessary scafolding up to a height of 20.00M complete all as specified and directed by Engineer in charge | 100 | Rm | 435 ₹43,500 | 180 ₹18,000 | 210 ₹21,000 | 420 ₹42,000 | 160 ₹16,000 Lowest | 160 ₹16,000 Lowest |
| 9.00 | Cleaning carefully (with fresh water) the blockage in CI / PVC Pipe 160mm dia pipe on walls & ensure all blockage perfectly cleared including necessary scafolding up to a height of 20.00M complete all as specified and directed by Engineer in charge | 50 | Rm | 430 ₹21,500 | 190 ₹9,500 | 240 ₹12,000 | 420 ₹21,000 | 180 ₹9,000 Lowest | 180 ₹9,000 Lowest |
| 10.00 | M&L for preparing new/old wall in side shaft surfaces for cleaning the fungi/algae growth by washing/scrubbing etc, including making arrangements for scaffolding and making good any damage/weak surfaces (plastering exceeding 0.5 Sqm shall be measured and paid in respective item) to match the existing surfaces complete all as specified and directed by Engineer in charge | 20 | Sqm | 415 ₹8,300 | 150 ₹3,000 Lowest | 350 ₹7,000 | 410 ₹8,200 | 310 ₹6,200 | 310 ₹6,200 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
20 Dec 2024, 6:00 pmClosed
GE Minniebay, Sri Vijaya Puram
GE, Minniebay, Junglighat (PO), Sri Vijaya Puram -744103
8398-REPAIRS AND CLEANING OF SEWAGE LINES , SEPTIC TANK, MAN HOLES , SOAKAGE PIT, DRAIN ETC AT DEF CIV COLONY, SRINAGAR COLONY AREA , STATIC EME WKSP, NT POOL AND CT POOL UNDER AGE B/R II OF GE MINNIEBAY, PORT BLAIR
2024_MES_652687_2
8398/E8
Open Tender
Civil Works
Item Rate
270 days
GE, Minniebay, Sri Vijaya Puram
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE Minniebay
₹80,000
23 Aug 2025
18 Nov 2024
23 Dec 2024
18 Nov 2024
20 Dec 2024
25 Nov 2024
Amount
De-watering & cleaning of septic tanks, soak well, manhole, sludge chamber etc. by pumping out sludge water manually or mechanically including cleaning of shrubs/bushes vegetation 2.50m around the septic tank , necessary cutting pit for sludge burying and making good to usable condition of the same complete all as specified and directed by Engineer in charge
Cleaning of sludges/silt from Nahani trap / floor trap including roding CI/PVC pipe from Nahani trap / floor trap to gully trap etc in position including removing of rubbish/sludge to a distance exc 250 m & n.exc 500 m complete all as specified and directed by Engineer in charge
Cleaning the blockage in IWC, EWC, including roding CI/PVC pipe after opening the oval asses door of PVC/CI bend, branch pieces etc upto first MH and placing the existing oval access door in original position including removing the rubbish/sludge to a distance exc 250m & n.exc 500m complete all as specified and directed by Engineer in charge
Systematicaly cleaning and desilting of pipe sewers of any type and dia upto 200 mm any depth by passing knots, bambboo, kamti and disc of required size, pumping out liquid waste/ sewage, plugging diverting the flow in the drain, if necessary and stacking the removed silt/ sludge in deposits as directed including taking precautionary measures such as safety belts, dry cells, torch for lighting in side the manholes and drain etc, sprinkling bleaching powder on the silt/ sludge removed to avoid bad smell and disposal of silt out side MD land complete all as specified and directed by Engineer in charge
Cleaning of drains (open) by desilting , including getting out depth up to 15 cm average of all vegetation, foreign materials, silt etc from drain and removing the materials outside MOD land complete all as specified and directed by Engineer in charge
Cleaning of drains by destiling mud, vegetation, debries waste materials deposits etc, cleaning/removing manually/mechanically up to a depth of 60 cm and removing the materials outside MOD land complete all as specified and directed by Engineer in charge
Cleaning carefully (with fresh water) the blockage in CI / PVC Pipe 75mm dia pipe on walls & ensure all blockage perfectly cleared including necessary scafolding up to a height of 20.00M complete all as specified and directed by Engineer in charge
Cleaning carefully (with fresh water) the blockage in CI / PVC Pipe 110mm dia pipe on walls & ensure all blockage perfectly cleared including necessary scafolding up to a height of 20.00M complete all as specified and directed by Engineer in charge
Cleaning carefully (with fresh water) the blockage in CI / PVC Pipe 160mm dia pipe on walls & ensure all blockage perfectly cleared including necessary scafolding up to a height of 20.00M complete all as specified and directed by Engineer in charge
M&L for preparing new/old wall in side shaft surfaces for cleaning the fungi/algae growth by washing/scrubbing etc, including making arrangements for scaffolding and making good any damage/weak surfaces (plastering exceeding 0.5 Sqm shall be measured and paid in respective item) to match the existing surfaces complete all as specified and directed by Engineer in charge
Taking down scrubs/vegitation growth from crevices completely upto any height and applying suitable chemical (herbicide) making good with PCC 1:2:4 or necessary plaster with CM 1:4 wiith WPC complete with all safety equipments complete all as specified and directed by Engineer in charge
Demolition of reinforced cement Concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level) (reinforcement cut as required to facilitate demolition) complete all as specified and directed by Engineer in charge
M&L for precast Manhole cover slab with PCC( 1:2:4) type B1 using 20mm graded stone aggregate incl cost of use and waste of clean sawn wooden form work but excl cost of reinforcement complete all as specified and directed by Engineer in charge
M&L for TMT bars 10mm dia cut to length, bent to shape required incl cranking and hooking ends and binding with MS wire (annealed) of dia not less than 0.90mm complete all as specified and directed by Engineer in charge
Demolition of Precast concrete work/ precast concrete block wall built in Cement Mortar including all quoins arches pillars etc complete all as specified and as directed by Engineer in charge
M & L for pre-cast cement concrete solid block masonry using PCC (1:3:6) , Type C-1(using 20 mm stone agg) , exc10 cm in width and setting in CM( 1:6) complete all as specified and as directed by Engineer in charge
S & F in repair PVC pipe 110mm dia any length as in weep holes fixed in PCC block masonary wall complete all as specified and as directed by Engineer in charge
Excavating in trenches soft /loose soil, n exc 1.5 m wide and n exc 1.5 m in depth for foundation, trench for drain pipes etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and as directed by Engineer in charge
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils complete all as specified and as directed by Engineer in charge
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m complete all as specified and as directed by Engineer in charge
M&L for PCC (1:4:8) nominal mix type -D2 (using 40 mm graded stone aggregate) in foundations, filling and mass-concrete complete all as specified and as directed by Engineer in charge
M & L for PCC ( 1:3:6) nominal mix type C2 (using 40 mm graded aggregate ) in surface channel and drain complete all as specified and as directed by Engineer in charge
M&L for 75mm thick cement concrete type D2, 1:4:8 (using 40 mm graded stone aggregate) in sub base of flooring/ hard standing.finishing the surface even & smoth without using extra cement complete all as specified and as directed by Engineer in charge
M& L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for internal dia of pipe 75/110/160 mm complete all as specified and as directed by Engineer in charge
S&F 160mm dia PVC (SWR) pipes single socketed in any length laid in trenches complete all as specified and as directed by Engineer in charge
M & L for concrete bed PCC 1:4:8 Type D2 to drain pipes 160 mm dia including packing under and and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed by Engineer in charge
Taking down Cement Plaster of any description on PCC block walls or concrete surfaces including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed by Engineer in charge. Note: Rate including necessary scafolding up to a height of G+3 bldg
M&L rendering 15mm thick in fair faces of PCC block wall or concrete surfaces in CM(1:4) finished even & fair without using extra cement complete all as specified and as directed by Engineer in charge
M&L for rendering 10 mm thick plaster in fair faces of PCC block wall or concrete surfaces in CM (1:6) finished even & smooth without using extra cement complete all as specified and as directed by Engineer in charge
M&L for rendering 5mm thick ceiling plaster in CM (1:3) on concrete surfaces finished even & smooth without using extra cement complete all as specified and as directed by Engineer in charge
Material & Labour for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed by Engineer in charge
M&L for applying two coats of oil bound distemper over a coat of primer on newly plastered surface of wall including preparation of surface, complete all as specified and as directed by Engineer in charge
M&L for applying two coats of oil bound distemper over a coat of primer on newly plastered surface of ceiling including preparation of surface, complete all as specified and as directed by Engineer in charge
M&L for applying putty of 1 mm thickness over plastered surface of wall/ceiling to prepare the surface even and smooth complete all as specified and as directed by Engineer in charge
Demolition of cement concrete(unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed by Engineer in charge
M&L for PCC 1:2:4 type B1 nominal mix (using 20mm graded aggregate) as in copings etc complete all as specified and as directed by Engineer in charge
M&L 75mm thick PCC 1:3:6 Type C-2 nominal mix using 20mm crushed stone aggregate as in plinth protection/Flooring finished even and fair without using extra cement complete all as specified and as directed by Engineer in charge
Dismantling Floor, Hearth or Wall Tiling including cement mortar bedding [but not backing] and removing serviceable tiles to the stores and removing rubbish / debris of the premises complete all as specified and as directed by Engineer in charge
M&L for coloured non-skid ceramic tiles 7 to 8 mm thick exc. 0.06 sqm but n.exc 0.11sqm area of each tiles in floor/ steps etc set and jointed in neat cement slurry and pointed in coloured cement to match as in floor over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed by Engineer in charge
M&L for glazed ceramic coloured/printed tiles 450x350x 7mm thick in vertical surface set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tile over 10mm thick backing in cement mortar (1:3) complete all as specified and as directed by Engineer in charge
M&L for coloured Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match as in floor over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed by Engineer in charge
All as per Item No.41 here in before but in vertical surface set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tile over 10mm thick backing in cement mortar (1:3) complete all as specified and as directed by Engineer in charge
M & L for coloured chequered cement concrete tiles 30 cm x 30cm x 25 mm thick in floors,steps, risers etc set and jointed neat cement slurry and pointed with With mixture of white & grey cement in equal proments & no pigment, over and including 15 mm thick screed bed in CM(1:4) etc. complete all as specified and as directed by Engineer in charge
M & L for coloured vitrified heavy duty tiles 300x 300x 10mm as in steps of staircase set and jointed in cement slurry and pointed in coloured cement to match laid over 15mm thick cement mortar in CM 1:6 complete all as specified and as directed by Engineer in charge
Taking down existing wash basins or kitchen sinks any size and type for repairs, refixing the same in position after necessary repairs / replacement of brackets with cement mortar 1:3 complete all as specified and as directed by Engineer in charge
S&F in repair 32mm waste coupling, brass, chromium plated for glazed ware sinks and basins etc, with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed by Engineer in charge
S&F in repair 40mm waste coupling, brass, chromium plated for glazed ware sinks and basins etc, with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed by Engineer in charge
S&F in repair PVC waste pipe 32mm dia for wash hand basin complete all as specified and as directed by Engineer in charge
S & F in repair PVC waste Pipe of size 40 mm for sink complete all as specified and as directed by Engineer in charge
S & F in repair bib taps, cast copper alloy, 15 mm dia, with crutch or butterfly handle, screwed down for iron pipe etc complete all as specified and as directed by Engineer in charge
Fixing only in repair bib cock including cleaning, removing of air block/washer etc of any type and size complete all as specified and as directed by Engineer in charge
S&F in repair two way bib tap cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for pipe or union fixed for 20mm bore PVC pipe complete all as specified and as directed by Engineer in charge
S & F in repair vitreous china wash hand basin, white, flat back of size 550 mm X 400 mm excluding pillar tap, and waste fittings including CI Brackets, cutting for and pinning in ends of brackets or erecting strand, complete all as specified and as directed by Engineer in charge
S & F in repair vitreous China Squatting Pan"Orissa pattern" water closet size 580 mmx440 mm white with integral foot rest etc. ( excluding cistern and flush pipe)& Provision of concrete bedding and making good to floor complete all as specified and as directed by Engineer in charge
S&F in repair vitreous China wash down water closet pan (Europeon ) of size 540x375x415mm 'P' trap or 'S' Trap (pedestal pattern), any colour including necessary fittings (excluding flushing cistern and flush pipe) complete all as specified and as directed by Engineer in charge
S&F in repair PVC flush tank low level cistern, 10 ltr capacity, including connecting to existing water supply line and water closet pan complete all as specified and as directed by Engineer in charge
Fixing only in repair by replacing minor parts like flushing knob, float, screws etc of PVC flush tank low level cistern, 10 ltr capacity, including connecting to existing water supplyline and water closet pan complete all as specified and as directed by Engineer in charge
S & F in repair pillar taps, cast copper alloy, Chromium Plated, 15 mm dia, with capstan head, screwed down high pressure with or with out lettered "Hot" or "Cold" with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and as directed by Engineer in charge
Fixing only in repair pillar taps including cleaning, removing of air block/washer etc of any type and size.
S&F in repair angular cock cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for pipe or union fixed for 15mm bore complete all as specified and as directed by Engineer in charge
Fixing only in repair angular cock including cleaning, removing of air block/washer etc of any type and size.
S&F in repair stop valves cast copper alloy chromium plated fancy type screwed down high pressure screwed both ends for pipe or union fixed for 15mm bore complete all as specified and as directed by Engineer in charge
Fixing only in repair stop cock including cleaning, removing of air block/washer etc of any type and size complete all as specified and as directed by Engineer in charge
S&F in repair stop valves cast copper alloy chromium plated with long shank and cup (concealed type) fancy type screwed down high pressure screwed both ends for pipe or union fixed for 15mm bore complete all as specified and as directed by Engineer in charge
Fixing only in repair concealed stop cock of any type and size after cleaning and removing of washer of blockage complete all as specified and as directed by Engineer in charge
S&F in repair gun metal gate valves with iron wheel head screwed both ends for iron pipe of dia 20mm complete all as specified and as directed by Engineer in charge
S&F in repair gun metal gate valves with iron wheel head screwed both ends for iron pipe of dia 25mm complete all as specified and as directed by Engineer in charge
S&F in repair flexible PVC connections 16mm size of length 450mm with, brass unions and rubber washers on either side for connecting water supply line to WHB, flush tank, etc complete all as specified and as directed by Engineer in charge
S&F in repair brass chromium plated shower rose with or without swivel joint 100mm size complete all as specified and as directed by Engineer in charge
S&F in repair 600 mm long CP Brass Towel Rail 20 mm dia fixed to wall with necessary chromium plated screws and wall plugs complete all as specified and as directed by Engineer in charge
S&F in repair kitchen sinks with drainage board made of stainless steel l.00mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm including waste fittings and couplings complete all as specified and as directed by Engineer in charge
S&F in repair stainless steel plate rack of size 900x 750 x 250 mm made of 1.00mm thick stainless steel fixed into wall with necessary brass screws and plugs complete all as specified and as directed by Engineer in charge
S&F in repair health faucet (ABS Body) mild steel chromium plated suitable for 20 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed by Engineer in charge
Taking out old unserviceable PVC Pipe of size 75mm , 110mm & 150mm from trenches and walls with all fittings complete all as specified and as directed by Engineer in charge
S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints,fixed to walls complete all as specified and as directed by Engineer in charge
S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints,laying in floors complete all as specified and as directed by Engineer in charge
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints,fixed to walls complete all as specified and as directed by Engineer in charge
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, laying in floors complete all as specified and as directed by Engineer in charge
S&F 160mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed by Engineer in charge
S&F 160mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in walls complete all as specified and as directed by Engineer in charge
Taking down of old serviciable pipes of any dia and refixing the same in old or new position after cleaning complete all as specified and as directed by Engineer in charge
S&F 75mm dia PVC (SWR) bend with oval access door complete all as specified and as directed by Engineer in charge
S&F 75mm dia PVC (SWR) bend /shoe without oval access door complete all as specified and as directed by Engineer in charge
S&F 75mm dia PVC (SWR) branch piece (single Y or T )equal or unequal with oval access door complete all as specified and as directed by Engineer in charge
S&F PVC (SWR) cowls 75mm dia complete all as specified and as directed by Engineer in charge
S&F 110mm dia PVC (SWR) bend with oval access door complete all as specified and as directed by Engineer in charge
S&F 110mm dia PVC (SWR) bend /shoe without oval access door complete all as specified and as directed by Engineer in charge
S&F110mm dia PVC (SWR) branch piece (single Y)equal or unequal with oval access door complete all as specified and as directed by Engineer in charge
S&F PVC (SWR) vent cowl 110mm dia complete all as specified and as directed by Engineer in charge
S&F in repair 75 mm PVC (SWR) floor trap, plain with grating incl jointing with solvent cement complete all as specified and as directed by Engineer in charge
S&F in repair 110 mm PVC (SWR) floor trap, plain with grating with incl jointing with solvent cement complete all as specified and as directed by Engineer in charge
S & F in repair PTMT Grating square /rounded150 mm size [Minimum weight 100 Grams] without waste hole or with waste hole to insert waste pipe complete all as specified and as directed by Engineer in charge
S & F in repair PTMT Grating square /rounded100 mm size [Minimum weight 100 Grams] without waste hole or with waste hole to insert waste pipe complete all as specified and as directed by Engineer in charge
Taking up or down old/chocked water tubings 15/20 mm bore with fittings from trenches /walls complete all as specified and as directed by Engineer in charge
Taking up or down old/chocked water tubings 25mm or 32 mm bore with fittings from trenches /walls complete all as specified and as directed by Engineer in charge
Refixing old steel tubing and connections of 15mm dia in new or old position (Walls, ceiling,floors, etc.) complete all as specified and as directed by Engineer in charge
Refixing old steel tubing and connections of 20mm dia in new or old position (Walls, ceiling,floors, etc.) complete all as specified and as directed by Engineer in charge
Refixing old steel tubing and connections of 25 or 32 mm dia in new or old position (Walls, ceiling,floors, etc.) complete all as specified and as directed by Engineer in charge
Supplying and laying of 20 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in walls/ trenches with necessary clamp, arrangements complete all as specified and as directed by Engineer in charge
Supplying and laying of 25 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in wall / trenches with necessary clamp , arrangements etc complete all as specified and as directed by Engineer in charge
S&F 20 mm bore CPVC Brass Elbow complete all as specified and as directed by Engineer in charge
S&F 20 mm Brass Elbow reducer(3/4 x1/2) complete all as specified and as directed by Engineer in charge
S&F 20mm bore CPVC Male Brass Threaded Adaptor complete all as specified and as directed by Engineer in charge
S&F 25mm bore CPVC Male Brass Threaded Adaptor complete all as specified and as directed by Engineer in charge
S&F 20mm bore CPVC Female Brass Threaded Adaptor complete all as specified and as directed by Engineer in charge
S&F 25mm bore CPVC Female Brass Threaded Adaptor complete all as specified and as directed by Engineer in charge
S&F 20 mm bore CPVC Brass Tee complete all as specified and as directed by Engineer in charge
S&F 25 mm bore CPVC Brass Tank Adaptor complete all as specified and as directed by Engineer in charge
S&F 20mm bore CPVC Brass Union complete all as specified and as directed by Engineer in charge
S&F 25mm bore CPVC Brass Union complete all as specified and as directed by Engineer in charge
M&L for cutting chases in concrete block walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 for concealed water tubing etc., and making good, cutting not exc 10 cm girth complete all as specified and as directed by Engineer in charge
M&L for treatment of sunken portion of WCs , Bath room Trap, Kitchen trap as per following stages including taking down previously treated materials :-
Stage 1 :- Demolition of WC including lime concrete and cement concrete coba etc and preparing the surface of existing sunken portion of WCs, bathroom trap, kitchen trap etc with wire brush to remove all loose dirt, oil grease etc . Stage 2:- Providing 10mm thick plaster in CM 1:4 with chemical of Dr. Fixit Pidicrete URP or plaster seal of STP Ltd. Stage 3:- Applying Dr Fixit Primseal primer or STP Ltd(and allow to dry for 8 hours) under touch dry condition. Stage 4:- Applying two coats of water proofing decorative elastomeric coating system of Dr Fixit Raincoats with DFT 100 Micron or shalicry 215 of STP(The surface after painting one coats shall be allowed to dry of 6 hours before next coats) all as per manufactutrer instruction. Stage 5:-Again rendering 10mm thick in CM 1:4 mixed with Dr Fixit Pidicrete URP or plaster seal of STP Ltd. Stage 6 : All CI joints shall filled with mixture of cement fine sand and plaster seal of STP Ltd or Dr Fixit pidicrete URP. Stage 7:- Making holes in wall and fixing 600mm long 20mm dia GI spout for draining the surplus water if any. (WC only)
M/s Shiva Engineering (BID ID -3177282)
BR ENTERPRISES (BID ID -3186284)
EXCEL ENGINEERING WORKS (BID ID -3187199)
M/s K Moorthi (BID ID -3188866)
CHANDER SEKER ENTERPRISE (BID ID -3188789)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .