Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance C 199 BULANDSHAHR ROAD INDUSTRAIL AREA GHAZIABAD UTTAR PRADESH 201001 | GHAZIABAD | UTTAR PRADESH | 201001 | Admitted-Finance |
| 2 | Admitted-Finance 114 HARGOVIND ENCLAVE KARKARDOMA NEW DELHI DELHI 110032 | SHAHDARA | DELHI | 110032 | Admitted-Finance |
| 3 | Admitted-Finance 17 17 WESTON STREET WESTON STREET KOLKATA WEST BENGAL 700013 | KOLKATA | WEST BENGAL | 700013 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
1 Oct 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Mr. Nilesh Sathe
thyssenKrupp Industrial Solutions (India) Private Limited (Formerly Uhde India Private Limited) Uhde House, L B S Marg, Vikhroli (W), Mumbai - 400083, India.
SUPPLY OF FLANGES and SPECTACLE BLINDS (Lot-5) for FUEL QUALITY UPGRADATION PROJECT at IOCL PARADIP Refinery
2021_REFHQ_140942_1
25284124-8230-RQ-000-0173
Limited
Mechanical - Piping, materials, flanges, valves, seals
Supply
90 days
IOCL Paradip Refinery
Please refer Tender documents.
5 documents required · 5 mandatory
Exempted
30 Nov 2021
17 Sept 2021
4 Oct 2021
17 Sept 2021
1 Oct 2021
24 Sept 2021
120 days
FLANGE- CARBON STEEL
WN FLG,CS, 150,0, B16.5, BW END,SCH STD,RF, FLANGE A105N
WN FLG,CS, 150,0, B16.5, BW END,SCH 160,RF, FLANGE A105N
WN FLG,CS, 150,0, B16.5, BW END,SCH 160,RF, FLANGE A105N
WN FLG,CS (NACE), 150,0, B16.5, BW END,SCH 160,RF, FLANGE A105N, ADD. INFORMATION, NACE REQ. ACC. TO NACE MR-0103, AND DOC. NO. PDRP-8440-SP-0026
WN FLG,CS (NACE), 150,0, B16.5, BW END,SCH 160,RF, FLANGE A105N, ADD. INFORMATION, NACE REQ. ACC. TO NACE MR-0103, AND DOC. NO. PDRP-8440-SP-0026
WN FLG,CS, 300,0, B16.5, BW END,SCH STD,RF, FLANGE A105N
WN FLG,CS (NACE+H2), 600,0, B16.5, BW END,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, NACE REQ. ACC. TO NACE MR-0103, AND DOC. NO. PDRP-8440-SP-0026, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007
WN FLG,CS (NACE), 600,0, B16.5, BW END,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, NACE REQ. ACC. TO NACE MR-0103, AND DOC. NO. PDRP-8440-SP-0026
WN FLG,CS, 600,0, B16.5, BW END,SCH XS,RF, FLANGE A105N
WN FLG,CS (NACE), 600,0, B16.5, BW END,SCH 160,RF, FLANGE A105N, ADD. INFORMATION, NACE REQ. ACC. TO NACE MR-0103, AND DOC. NO. PDRP-8440-SP-0026
WN FLG,CS (NACE), 600,0, B16.5, BW END,SCH 160,RF, FLANGE A105N, ADD. INFORMATION, NACE REQ. ACC. TO NACE MR-0103, AND DOC. NO. PDRP-8440-SP-0026
WN FLG,CS (NACE), 600,0, B16.5, BW END,SCH 160,RF, FLANGE A105N, ADD. INFORMATION, NACE REQ. ACC. TO NACE MR-0103, AND DOC. NO. PDRP-8440-SP-0026
WN FLG,LTCS (NACE), 300,0, B16.5, BW END,SCH STD,RF, FLANGE A350 Gr.LF2 CL.1, ADD. INFORMATION, NACE REQ. ACC. TO NACE MR-0103, AND DOC. NO. PDRP-8440-SP-0026
WN FLG,LTCS (NACE), 300,0, B16.5, BW END,SCH STD,RF, FLANGE A350 Gr.LF2 CL.1, ADD. INFORMATION, NACE REQ. ACC. TO NACE MR-0103, AND DOC. NO. PDRP-8440-SP-0026
WN FLG,LTCS (NACE), 300,0, B16.5, BW END,SCH 160,RF, FLANGE A350 Gr.LF2 CL.1, ADD. INFORMATION, NACE REQ. ACC. TO NACE MR-0103, AND DOC. NO. PDRP-8440-SP-0026
WN FLG,CS (IBR), 150,0, B16.5, BW END,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, IBR CERTIFICATE IN FORM IIIC REQUIRED
WN FLG,CS (IBR), 300,0, B16.5, BW END,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, IBR CERTIFICATE IN FORM IIIC REQUIRED
WN FLG,CS (H2 SER.), 900,0, B16.5, BW END,SCH 80,RTJ, FLANGE A105N, ADD. INFORMATION, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007
WN FLG,CS (H2 SER.), 900,0, B16.5, BW END,SCH 80,RTJ, FLANGE A105N, ADD. INFORMATION, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007
WN FLG,CS (H2 SER.), 900,0, B16.5, BW END,SCH 120,RTJ, FLANGE A105N, ADD. INFORMATION, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007
WN FLG,CS, 1500,0, B16.5, BW END,SCH XS,RTJ, FLANGE A105N
WN FLG,CS (H2 SER.), 1500,0, B16.5, BW END,SCH XS,RTJ, FLANGE A105N, ADD. INFORMATION, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007
WN FLG,CS (NACE), 1500,0, B16.5, BW END,SCH XS,RTJ, FLANGE A105N, ADD. INFORMATION, NACE REQ. ACC. TO NACE MR-0103, AND DOC. NO. PDRP-8440-SP-0026
WN FLG,CS, 1500,0, B16.5, BW END,SCH 160,RTJ, FLANGE A105N
WN FLG,CS (NACE+H2), 1500,0, B16.5, BW END,SCH 160,RTJ, FLANGE A105N, ADD. INFORMATION, NACE REQ. ACC. TO NACE MR-0103, AND DOC. NO. PDRP-8440-SP-0026, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007
WN FLG,CS (H2 SER.), 1500,0, B16.5, BW END,SCH 160,RTJ, FLANGE A105N, ADD. INFORMATION, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007
BF,CS, 150,0, B16.5, RF, FLANGE A105N
BF,CS, 150,0, B16.5, RF, FLANGE A105N
BF,LTCS, 300,0, B16.5, RF, FLANGE A350 Gr.LF2 CL.1
BF,LTCS (NACE), 300,0, B16.5, RF, FLANGE A350 Gr.LF2 CL.1, ADD. INFORMATION, NACE REQ. ACC. TO NACE MR-0103, AND DOC. NO. PDRP-8440-SP-0026
BF,LTCS (NACE), 300,0, B16.5, RF, FLANGE A350 Gr.LF2 CL.1, ADD. INFORMATION, NACE REQ. ACC. TO NACE MR-0103, AND DOC. NO. PDRP-8440-SP-0026
BF,CS (GALV.), 150,0, B16.5, RF, FLANGE A105N (GALV.)
BF,CS (GALV.), 150,0, B16.5, RF, FLANGE A105N (GALV.)
THREADED FLANGE,CS (GALV.), 150,0, B16.5, RF, THREADED FLANGE WITH HUB, FLANGE A105N (GALV.)
THREADED FLANGE,CS (GALV.), 150,0, B16.5, RF, THREADED FLANGE WITH HUB, FLANGE A105N (GALV.)
SO FLG,CS, 150,0, B16.5, RF, FLANGE A105N
SO FLG,CS (GALV.), 150,0, B16.5, RF, FLANGE A105N (GALV.)
SO FLG,CS (GALV.), 150,0, B16.5, RF, FLANGE A105N (GALV.)
SO FLG,CS (GALV.), 150,0, B16.5, RF, FLANGE A105N (GALV.)
SW FLG,CS, 150,0, B16.5, SW END,SCH XS,RF, FLANGE A105N
SW FLG,CS, 150,0, B16.5, SW END,SCH XS,RF, FLANGE A105N
SW FLG,CS, 150,0, B16.5, SW END,SCH 160,RF, FLANGE A105N
SW FLG,CS, 150,0, B16.5, SW END,SCH 160,RF, FLANGE A105N
SW FLG,CS (H2 SER.), 300,0, B16.5, SW END,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007
SW FLG,CS (H2 SER.), 600,0, B16.5, SW END,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007
SW FLG,CS, 600,0, B16.5, SW END,SCH 160,RF, FLANGE A105N
SW FLG,LTCS, 300,0, B16.5, SW END,SCH 160,RF, FLANGE A350 Gr.LF2 CL.1
FLANGE-ALLOY STEEL
BF,AS, 600,0, B16.5, RF, NORMALIZED & TEMPERED, FLANGE A182 Gr.F11 CL.2
SW FLG,AS (H2 SER.), 600,0, B16.5, SW END,SCH 160,RF, NORMALIZED & TEMPERED, FLANGE A182 Gr.F11 CL.2, ADD. INFORMATION, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007
FLANGE-STAINLESS STEEL
WN FLG,SS DUAL (NACE+H2), 600,0, B16.5, BW END,SCH 80S,RF, FLANGE A182 Gr.F304/304L, SUPP. REQUIREMENTS, SHALL BE DUAL CERTIFIED., ADD. INFORMATION, NACE REQ. ACC. TO NACE MR-0103, AND DOC. NO. PDRP-8440-SP-0026, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007
WN FLG,SS DUAL (NACE+H2), 600,0, B16.5, BW END,SCH 80S,RF, FLANGE A182 Gr.F304/304L, SUPP. REQUIREMENTS, SHALL BE DUAL CERTIFIED., ADD. INFORMATION, NACE REQ. ACC. TO NACE MR-0103, AND DOC. NO. PDRP-8440-SP-0026, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007
WN FLG,SS, 150,0, B16.5, BW END,SCH 80S,RF, FLANGE A182 Gr.F304L
WN FLG,SS, 150,0, B16.5, BW END,SCH 80S,RF, FLANGE A182 Gr.F304L
WN FLG,SS, 150,0, B16.5, BW END,SCH 80S,RF, FLANGE A182 Gr.F304L
WN FLG,SS, 150,0, B16.5, BW END,SCH 10S,RF, FLANGE A182 Gr.F316L
WN FLG,SS, 150,0, B16.5, BW END,SCH 10S,RF, FLANGE A182 Gr.F316L
WN FLG,SS, 150,0, B16.5, BW END,SCH 80S,RF, FLANGE A182 Gr.F316L
BF,SS DUAL (NACE+H2), 600,0, B16.5, RF, FLANGE A182 Gr.F304/304L, SUPP. REQUIREMENTS, SHALL BE DUAL CERTIFIED., ADD. INFORMATION, NACE REQ. ACC. TO NACE MR-0103, AND DOC. NO. PDRP-8440-SP-0026, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007
BF,SS, 150,0, B16.5, RF, FLANGE A182 Gr.F304
SW FLG,SS, 150,0, B16.5, SW END,SCH 40S,RF, FLANGE A182 Gr.F304
SW FLG,SS, 150,0, B16.5, SW END,SCH 80S,RF, FLANGE A182 Gr.F304
SW FLG,SS, 150,0, B16.5, SW END,SCH 80S,RF, FLANGE A182 Gr.F304
SW FLG,SS, 300,0, B16.5, SW END,SCH 80S,RF, FLANGE A182 Gr.F304L
SW FLG,SS, 600,0, B16.5, SW END,SCH 80S,RF, FLANGE A182 Gr.F304L
SPECTACLE BLIND
SBLD,LTCS (NACE), 300,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, SERVICE NACE, LOW SEVERITY, NORMALIZED, IMPACT TESTED, A516 Gr.70, ADD. INFORMATION, NACE REQ. ACC. TO NACE MR-0103, AND DOC. PDRP-8440-SP-0026, SUPP. REQ. S5 ACC. TO ASTM A516 (Ed.2017).
SBLD,SS DUAL (NACE+H2), 600,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A240 Gr.304/304L, SUPP. REQUIREMENTS, SHALL BE DUAL CERTIFIED., ADD. INFORMATION, NACE REQ. ACC. TO NACE MR-0103, AND DOC. PDRP-8440-SP-0026, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007
SBLD,LTCS (NACE+H2), 900,0, B16.48, FOR RTJ FLGS,B16.5, FIGURE 8, FEMALE RTJ, SERVICE NACE, LOW SEVERITY, NORMALIZED, IMPACT TESTED, A516 Gr.70, ADD. INFORMATION, NACE REQ. ACC. TO NACE MR-0103, AND DOC. PDRP-8440-SP-0026, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, SUPP. REQ. S5 ACC. TO ASTM A516 (Ed.2017).
STEEL AIIDS ENTERPRISE PRIVATE LIMITED
M.S.FITTINGS MFG. CO. PVT. LTD.
C D Engineering Company
R D FORGE(A unit of R D CHEMICALS PVT LTD))
Triveni refractories P Ltd
Maxell Forge Industries
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .