Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.5 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹35.5 L+₹44,987 (1.28%)Rejected-Finance | L2 | Rejected-Finance Being not Lowest | |
| 3 | L3₹37.0 L+₹1.9 L (5.55%)Rejected-Finance | L3 | Rejected-Finance Being not Lowest | |
| 4 | L4₹38.7 L+₹3.6 L (10.3%)Rejected-Finance | L4 | Rejected-Finance Being not Lowest | |
| 5 | L5₹41.4 L+₹6.3 L (18.0%)Rejected-Finance | L5 | Rejected-Finance Being not Lowest |
Tender Value
₹44.9 L
EMD Value
₹89,720
Closing Date
11 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (West) Delhi Cantt-10.
GE (West) Delhi Cantt-10.
Addn/Altn to Bldg No P-154 at 629 TPT Coy ASC in the area of AGE B/R-III under GE (West) Delhi Cantt-10.
2024_MES_646609_1
GE/DW-95/2023-24
Open Tender
Civil Works
Item Rate
180 days
DELHI CANTT
Class D Category a(i)
8 documents required · 8 mandatory
₹500
GE (West) Delhi Cantt
₹89,720
Yes
3 Jun 2024
15 Mar 2024
13 Apr 2024
15 Mar 2024
11 Apr 2024
29 Mar 2024
Amount
Providing and applying a non shrink, polymer modified cementitious micro-concrete Rendroc RG or equivalent from SIKA/BASF having compressive strength (BS 4551-80)-50 Mpa at 28 Days, Tensile strength- 2 Mpa @ 28 Days, Flexural Strength(BS 4551-80)-5 Mpa at 28 Days. product shall have A1 Class Fire Rating confirming to EN1504 cl 5.5, Thermal conductivity of 1.5W/m degree C. Renderoc RG can be applied in sections upto 100mm deep. Pouring the same into the formwork using suitable arrangement or if required using pumping device for uniform flow of micro concrete. Rate is inclusive of preparatory works from item i) to item v) below, rates also includes cost of materials labour, tools and plants, cost of shuttering & scaffolding, safety arrangement quality control and testing etc. complete as per specification and as directed by Engineer.-in-charge. .
i) Chipping of plaster and unsound/weak concrete material till reinforcement bars are exposed, which enabls their rust removal vides item ii) below, from slabs, beams, and columns etc. with standard power driven percussion type or pneumatic chisel of standard make as directed by Engineer-incharge including tapering all edges, making square shoulders of cavities etc complete and disposal of debris up for all lifts and leads. .
ii) ) Rust removal by Providing and applying Fosroc Reebaklens RR or equivalnet from SIKA/ BASF, a combination of acid based material, corrosion inhibitors and dispersing agents rust remover, for removal of all rust/ scales/corrosion from reinforcement bars before microconcreting or patch repair,It Shall be applied with brush for complete wetting of rusted metal surface at coverage of 2- 2.5 Sqm/ltr. & allow it to react for 16-24 hours. After 24 hours, a white layer will appear which will protect further corrosion of metal /steel for about 5-7 days. Before applying any protective coating, the surface should be wire brushed and thoroughly cleaned for dust with dry cloth
iii) Anticorrosive treatment by Providing and applying Nitozinc Primer an epoxy based zinc rich anti corrosive primer having adhesive bond strength ≥ 1.5 MPa as per ASTM D4541, & shall comply to per ASTM B-117 to be applied on well cleaned, fully exposed and all loose scale, rust free rust free surface obtained by grit blasting or suitable means , to be done with coverage @4.5sqm/litres to achieve a minimum thickness of 40microns DFT or as per direction of Engineer-In charge.
iv) Epoxy bonding for Old concrete & New concrete by providing and applying bond coat on the prepared surface with two component epoxy based bonding coat Nitobond EP of Fosroc make or equivalent, having specific gravity 1.15 to 1.2 gm/cc, Compressive strength(BS 6319 Pt.2)- 50 Mpa at 7 days, Flexural strength strength(BS 6319 Pt.3)- 35 Mpa at 7 days, Tensile strength (BS 6319 Pt.7)- 20 Mpa at 7 days, Shear Strength (BS 6319 Pt.4)- 10 Mpa at 7 days, having an over lay time of 6 hrs and 30 ̊C. Bonding agent shall have coverage not less than 2.5sqm/litres Laying of reinstatement polymer modified mortar or micro concrete shall be completed within the overlay time of bonding coat. Item rate is inclusive of materials all labour, tools and tackles. complete as per specification and as directed by Engg.-in-charge.
v) Work will complete only after proper wet curing has been done and testing of Microconcrete cubes filled up and cured by contractor during column jacketing work (100 mm size cube crushing strength at the end of 28-day to be not less than 45 N/sq.mm) and NDT tests mandated under item "Testing of works"
Taking down chowkats or frames exc. 1.5 sq. m but not exc 4 sqm each with shutters (without taking off shutters from the frames) , complete all as specified and directed.
Taking down old window / ventilators with frame, any description, including guard bars not exc 1.5 sqm each , complete all as specified and directed.
S&F Anodised aluminium window and ventilator shutters, side hung type or fixed type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays/tower bolt 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed.
S&F powder coated ( min thickness 50 micron )Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S&F for Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, fixing of nuts and bolts as necessary, gusset plates, riveting, etc., conforming to Fe -290 Gde E-165 complete all as specified and directed.
S & F for mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors, angle iron chowkhats; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 including fixing of hold fast with bed block of size 200x200x15mm in CM 1:2:4 (using 20mm graded agg complete all as specified and directed. .
M&L for preparation of new steel surfaces over 10 cm width or girth, not otherwise described and applying two coat of synthetic enamel painting over a coat of red oxide primer etc all as specified and directed.
S & F factory made 35 mm thick 2nd class hardwood Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated incl one shop coat of pink primer complete all as specified and directed.
S&F 35 mm thick 2nd class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats incl one shop coat of pink primer complete all as specified and directed.
M & L for preparation of new or previously untreated wood or wood based surface of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint (approved tint) over a coat of pink primer complete as specified and directed.
S & F stainless steel butt hinges 100mm long medium weight etc complete all as specified and directed.
S & F 200mm long aluminum, anodized barrel tower bolts of extruded section complete all as specified & directed.
S & F aluminum anodised handle 150 mm long cast type complete all as specified & directed.
S & F 300mm long aluminium alloy anodised sliding door bolt hasp staple (bolt type) and clips of sheet cast of extruded section fixing bolts and sliding bolts of extrude section complete all as specified & directed.
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples (for windows and gauzed doors) all as specified and directed.
S&F figured sheet glass, 4mm thick, pin head type fixed with clips or putty complete in squares n.exc 0.50 Sqm each pane complete all as specified and directed.
M&L preparation of old painted of wood or wood based surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old painted to steel and iron surfaces of any description over 10 cm width or girth not other wise described and applying one coat of synthetic enamel paint including easening of steel window by providing lubricant oil to hinges/pivot complete all as specified and directed.
S&F in repair110 mm bore PVC (SWR) pipes single socket in any length with rubber ring/ cement solvent cement jointsfixed to walls incl MS clamps of suitable size made of flat iron 25x3mm including taking down old unsv pipes complete all as specified and directed.
S&F PVC bend/tee suitable for 110mm bore pipe complete all as directed
Complete removal of existing treatment of wall/Ceiling using wire brush/mechanical/ electrical driven sanders, washing, rubbing down and stoping of painted surface including preparation of surface etc complete all as specified and directed.
M&L for applying layer of 1mm thick white wall care putty for finishing the surface even to true aligned surface of wall/ceiling and smooth using sand papers etc all as specified and directed by Engineer-in-charge Make : Birla white/JK white/Altek
M&L for applying two coats of oil bound distemper including Priming plastered and other surfaces with alkaliresistant priming pain on prepared surfaces (approved quality & tint) using machine spray on wall all as specified and directed.
M&L for applying two coat of cement base paint (approved quality & tint) complete all as specified and directed.
M&L for applying two coats of oil bound distemper on prepared surfaces (approved quality & tint) using machine spray on ceiling complete all as specified and directed.
M&L rendering 15 mm thick in ready mix mortar of approved makeon brick work or concrete on walls , finish the surface even and smooth without using extra cement as whole or in patch incl taking down old cement plaster of any description, complete all as specified and directed. Note:- (i) Cost for necessary steel formwork & shuttering of the above aspects shall be deemed to be included in the quoted rate of the respective item and nothing extra shall be paid on any account.
M&L for rendering 10 mm thick ready mix mortar of approved make on ceiling and finished even and smooth incl taking down old plaster, complete all as specified and directed.
M&L for preparing newly plastered surfaces on walls and applying two coat of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls applying birla white putty 1 mm on wall even and smooth surface and applying two coat of oil bound distemper over a coat of alkali resistance primer (of approved quality and tint) on wall using painting roller, complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying two coats of white wash on ceiling complete all as specified and directed.
Demolition of cement concrete unreinforced in ground floor and paving n.exc 15CM thickness (below or above ground levelall complete all as specified and directed.
M&L for Plinth protection 75 mm thick in PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) laid in alternate bays(not exc 2 Sqm each) finished even and fair at top using extra cement and providing joints throughout the thickness of plinth protection, filled with mastic filling comprising one part of bitumen 85/25 graded and three parts of sand by weight all as directed at site complete all as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar incl all quoins, arches, pillars etc but excluding ashlars facings dressed stone work and Precast concrete articles, complete all as sfd and directed.
M&L for Brick work with Sub class 'B' bricks straight or curved on plan exceeding 6m mean radius, built in Cement mortar 1:6 complete all as specified and directed.
M&L for Brick work with Sub class 'B' bricks straight or curved on plan to any radious in half brick thick walls, built in Cement mortar 1:4 complete all as specified and directed.
M&L for Providing precast cement concrete type B0 1:2:4 (12.5 mm graded agg) louvres and jallies, 25mm thick (measured solid), including all mouldingsfixed to brick/concrete surfaces with cement mortor 1:4 complete all as specified and directed.
Dismantling of floor, hearth or walling including cement mortar bedding (but not backing removing serviceable to store and rubbish off the premises complete all as specified and directed.
M&L for Machine cut kota stone as in treads and risers (in one piece) 18-20mm thick over 15mm thick cement screed base in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing incl demolition of old stone slab of any description complete all as spd & directed.
M&L kota stone grinding and polishing with bees wax making glazed finish jointed with grey cement slurry complete all as specified and directed.
M&L for repairing of spalled concrete from ceiling in the following stages:- a. Prepration of existing surfaces like chipping of unsound weak / loose concrete with electric hammer or manually including tapering all edges, making square shoulders of cavities etc. n.exc 50 mm thickness removal of debries, complete all specified and directed by the Engineer-in-charge. b. Applying rust remover cum passivator Sika rustoff 100 or equivelent @ 0.20kg/Sqm/per coat or as per manufacturer's specifications to remove rust from existing reinforcement (Make : Sika or equivalent) c. Applying a epoxy based zinc rich rebar corrosion protection system of product : Fiazin (R) R @ 0.15Kg/Sqm/coat or as per manufacturer's specifications (Make ; Sika or equivalent) d. Mixing & applying two component Epoxy resin concrete Bonding coat of Sikadur(R)-32 LP A & B @ 0.40 Kg/Sqm(Mixing proportion as per manufacturer's instructions) on prepared RCC surfaces as per manufacture specification including prepartaion of surface by chipping and throughly cleaning of surface complete whereever required over new reinforcement (if required) and as directed by the Engineer-in-charge.(Make : Sika) (Reinforcement will be measured and paid separatley). e. Apply a pre-batched one component polymer modified cementious patch repair mortar n.exc 50mm in layer of 15mm thick each of Product: Sika Mono Top®-122 F as per manufacturer insturctions and as directed by the Engr-in-Charge. f. Apply aluminised synthetic resin Concrete curing compounds for the prevention of premature water loss from concrete of product: Antisol®-E(WP) @ 0.10 to 0.20 kg/m2 as manufacturers instructions and as directed by the Engr-in-Charge.
Supply & fixing 12mm dia steel sheer connector in grid pattern in between old core and new concreate as wherever directed by Engr-in-Charge and as specified by manufactorer including drilling hole of depth of 100 mm and chemical anchoring with pure epoxy resin anchoring mortar SIKA anchor fix 3030 or equivalent of Hilte /Fischer.( The cost of drilling hole & chemical anchoring with epoxy resin is inclueded in this item) complete all as specified and directed.
M&L for drilling & chemical anchoring of new rebars/stirrups :- (i) Drilling in to the sound RCC members for anchorings of rebars/stirrups as directed, the dia of hole to be match with dia of rebar & length of drilling as under :- 8 -12 mm dia bar- drilling length 80 to 100 mm complete all as specified and directed. Note : Anchorings of new re-bars of any dia as directed in to the sound RCC members as directed using pure epoxy resin anchoring mortar SIKA anchoc Fix 3030 or equivalent hilti/Fisher with appropriate diameter of drilling of holes as mentioned above for proper bonding into the concrete etc. , compete. (The cost of drilling hole & chemical anchoring with epoxy resin is included in this item )
M&L form work to sides and soffits of floor or roof beams, beams, columns, slabs haunchings, griders bressummers lintels, cantilevers shelves including sup-ports, overhangs, etc also splays between floors and beams etc, complete all as specified and directed.
Demolition of reinforced cement concrete roofs, floors (other than ground floor), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed.
M&L for ready mix concrete (RMC) of design mix M-25 (using 20mm graded stone aggregate) as in slabs, lintels supported on walls, beams and columns in floors, roofs landings, balconies canopies,deck slabs and in shelves and the like complete all as specified and directed.
S&F TMT bars 10mm dia and over, cut to lenght, bent to shape required, including cranking, bending spirally for hooping for coloums, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
S&F TMT bars 6mm to 8mm dia cut to lenght, bent to shape required, including cranking, bending spirally for hooping for coloums, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
All as per Srl item No. 22 above but TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation. etc) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
Dismantling of brick tiles or terracing tiles single layer on roof complete all as specified and directed.
M & L for PCC tiles of size 25cm x 25cm x 22mm thick set and jointed grey cement with pigment in cement mortar over and including 10mm thick cement plaster in CM 1:4 complete all as specified and directed.
Demolition of mud phuska on roof slabs, any thickness incl cleaning of roof surfaces and removing the debris out of MOD land complete all as specified and directed.
Scraping of old tar felt roof treatment over concrete padding of any thickness etc from roof incl finishes or junction or parapet and cleaning the surface (by mechanical means like grinder, etc) complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) on roof padding with water proofing compound surface finished even and smooth without using extra cement complete all as spd & directed. (Rate of WPC shall be included in unit rate)complete all as specified and directed.
M&L for water proofing treatment in following stages:- 1. Rendering in CM 1:3 with waterproofing liquid as per manufacturer's instruction over concrete surface finished even and smooth without using extra cement. 2. First coat of bitumen primer confirming to IS-3384@ 0.40 Kg/Sqm over plastered surface.(Bitumen primer shall be TANK MASTIC of M/S STP Ltd or ‘EMW FLATE’ of M/S Texas India Ltd). 3. Second coat of binding material using blown type bitumen confirming to IS-702 Gde 85/25 @ 1.2 Kg/Sqm applied over bitumen primer. 4. Third layer of APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.0 Kg/Sqm with a centre core of 90 micron high density polyethylene film protected on both sides with a high quality polymeric asphaltic mix, the polymeric asphaltic mix will be protected on both sides with thermo fusable HMHDPE film of make super thermolay manufactured by STP Ltd or ‘Hyper Plas’ (Polyster) manufactured by M/S IWL Ltd or ‘Shaliplas’ (polyester) manufactured by M/S Capital Steels and chemicals Pvt Ltd as approved by GE, black finish reinforced with non-woven polyester matt, with a thermo fusable finish.torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at the sides and 100mm at the ends complete all as specified and as directed.
Taking down carefully copper/aluminium any type of point wiring (light/fan/socket /power) complete (fittings such as switches, ceiling roses, holders, sockets,regulators light fittings) and making good the disturbed surfaces of wall/floors/ceiling etc) complete all as specfied & directed.
Material and labour for concealed point wiring with PVC insulated unsheathed multistranded colour code copper conductor in PVC conduit with FRLS cable1.5 Sqmm size 1100 volts grade conforming to IS:694 in box of suitable thickness including one coat of synthetic enmelled black paint and providing with brass screws and cup washers including single core multi stranded FRLS copper conductor 1.5 Sqmm PVC insulated cable as earth wire to common earth and connected to earth dolly and earth terminal box drawn in same concealed conduit all as specified and directed by Engr-in-charge for the following :- (a) One light/fan/bell point controlled by one way switch 5 amps.
(b) One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
(c) One 3 pin 5 Amps socket outlet point controlled by one way switch on same board.
Material and Labour for concealed point wiring with PVC insulated unsheathed multistranded FRLS copper conductor in PVC conduit with cable 2.5 Sqmm size 1100 volts grade conforming to IS:694 in box of suitable thickness including one coat of syenthetic enamelled black paint with new modular white cover plate with frame of suitable size of required colour fixed with brass screws and cup washers including single core multi stranded FRLS copper conductor 1.5 Sqmm PVC insulated cable as earth wire to common earth and connected to earth dolly and earth terminal box drawn in same concealed conduit for One 3 Pin socket 15A Indepentent board complete all as specified and directed.
S&F of switch piano type 5 amps single pole one way complete all as specified and directed.
S&F of switch piano type 15 amps single pole one way complete all as specified and directed.
S&F of socket outlet multipurpose 2/3 pin 5 amps flush button type complete all as specified and directed.
S&F of socket outlet multipurpose 2 in 1, 5 and 15 Amps complete all as specified and directed.
S&F of ceiling fan regulator step type for 1200/1400 mm sweep ceiling fan including connections complete all as specified and directed.
Supply, laying and drawing submain wiring in and including 20 mm dia concealed PVC rigid conduits including cutting of chases for laying conduit making good the surfaces as per existing surfaces or as directed on walls 02 runs of IC x 6.00 sqmm (Main Cable and neutral) and one run of IC x 6.0 sqmm (as earth wire) of multistranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete including connection all as specified and directed.
Taking down ceiling fan, sealing cable end, dismantling blades and removing fan and blades and deposit to MES store to store complete all as specified and directed.
Supply & fixing ceiling fans complete with blades, down rod, electronic regulator and accessories, 230 volt, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
S&F of factory made epoxy polyester powder coated distribution board SP & N 12 way fabricated from minimum 1.6 mm thick CRCA sheet with metal double door (IP-43 protection ) fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, eath bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as incomer and 6 SP MCBs as outgoings complete all as specified and conforming to IS: 8623 alongwith cable end box for above DB all as specified and directed. NOTE (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
S&F of factory made epoxy polyester powder coated distribution board TP & N 4 way (VTPN MCCB DB) with metal double door (IP-54 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for DPX 160, 4 pole MCCB and ELM as incommer and 12 SP MCBs outgoings complete all as specified and conforming to IS: 8623 along with cable end box for above DB including taking down old DBs all as specified. NOTE :- (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
S&F in of MCCB 125 Amp 4 pole 16 KA at 415 V with fixed thermal megnatic release complete all as specified directed.
S&F of single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘B’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 including taking down old MCB's complete all as specified and directed.
S&F of SPN MCB 32 amp, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘C’ curve, 10 KA breaking capacity, complete all as specified and directed.
S&F surface mounting LED integrated Aluminium batten luminaire polycarbonete co-extusion tube for not less than 20W LED light (4 ft) housing. Fixture should have minimum efficiency at system level >=120 lumens/Watt, life of fixture not less than 50K Hrs; Ripple<5%,UGR<19, minimum Surge protection level of 4 KV, CCT 4000-6500K with same lumens/w CRI>80, PF>0.95 THD<10% @ 240 V AC. An operating voltage range of 140-270V including all connection upto ceiling rose complete all as specifiec and directed.
Supply and fixing LED Building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. complete all as specified and directed.
S&F ceiling rose 3 phase/PVC/polycarbonate isolated body complete all as specified and directed.
M&L far Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, burieddirectly in ground (earth pit not lessthan 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed.
SHRI JI ENTERPRISES
GENIMAA PRIVATE LIMITED
JAIPAL AND BROTHERS
M/s M M BAHL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .