| 1 | L1₹23.5 LAccepted-AOC A 249 1ST FLOOR TODAY BLOSSOM 1 SEC 47 GURUGRAM | GURUGRAM | GURUGRAM | HARYANA | L1 | Accepted-AOC Awarded | |
| 2 | L2₹37.7 L+₹52,677 (1.42%)Rejected-Finance 57 C STREET NO 6 WEST RAJIV NAGAR 122001 | GURUGRAM | GURUGRAM | HARYANA | 122001 | L2 | Rejected-Finance L2, Hence Rejected | |
| 3 | L3₹41.6 L+₹4.5 L (12.1%)Rejected-Finance | L3 | Rejected-Finance L3, Hence Rejected | |
| 4 | L4₹41.8 L+₹4.7 L (12.6%)Rejected-Finance | L4 | Rejected-Finance L4, Hence Rejected | |
| 5 | L5₹42.5 L+₹5.3 L (14.4%)Rejected-Finance | L5 | Rejected-Finance L5, Hence Rejected |
Tender Value
₹32.1 L
EMD Value
₹64,200
Closing Date
16 Sept 2021, 5:00 pmClosed
Executive Engineer, Elec Division, GMDA
Executive Engineer, Elec Division, GMDA, Plot No.3, Sector-44, Gurugram
Providing and installation of 1250 KVA Transformer at in Sector-51 Boosting Station, Supplying Power to Part-2 of the Boosting Station-51, Gurugram.
2021_HRY_183947_1
Job No.1/2021 Elect. Division GMDA
Open Tender
Electrical Works
Works
180 days
Gurugram
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
₹64,200
12 Jan 2022
26 Aug 2021
17 Sept 2021
26 Aug 2021
16 Sept 2021
26 Aug 2021
Amount
NS Item Design, manufacture, supply, installation, testing and commissioning,11 KV/ 433V, 3 phase, 50 Hz delta/star connected, outdoor type, copper wound transformer, oil immersed ONAN cooled, Sudhir make/ kirloskar make transformer 1250 KVA complete with all fittings such as oil conservator, silica gel breather, thermometer, explosion vent, Off load tap changer with + 5 % to – 10 %, tappings at steps of 1.25 %, bidirectional roller, diagrams & rating plate, Magnetic Oil gauge, Oil temperature indicator, & Winding temperature indicator, Buchholz relay, marshalling Box (having Alarm/trip, WTI CT, NCT contacts/terminal block of OTI, WTI, MOG, BR, SOR & 16A socket, space heater, thermostat, LED lamp etc.) lifting lugs, first filling of oil, weather proof .complete as per relevant IS: 1180 part-1, energy efficiency level-2 specifications.
NS Item Supply, assembling, installing, testing and commissioning all the items for making GI plate earthing station comprises of one number GI. earthing plate 600 x 600 mm thick, 50 mm dia medium class GI watering pipe, (minimum 6 m deep) , common salt, charcoal powder, earthing conductor size 50 x 6 mm GI from the plate to the ground level .
NS Item Supply & installation of G.I Strip of 50mm x 6mm for earthing purpose complete in all respect upto entire satisfaction of engineer incharge.
NS Item Supply, assembling, installing, testing and commissioning all the items for making Copper plate earthing station comprises of one number Copper. earthing plate 600 x 600 mm thick, 50 mm dia medium class Copper watering pipe, (minimum 6 m deep) , common salt, charcoal powder, earthing conductor size 50 x 6 mm Copper from the plate to the ground level .
NS Item Supply & installation of Copper Strip of 50mm x 6mm for earthing purpose complete in all respect upto entire satisfaction of engineer incharge.
NS Item Supply, Installation, Testing & Commissioning of following size heat shrinkable cable termination kit including all accessories and material to make a complete joint. Make DHBVN approved (i) 3 C x 185 sq.mm 11 KV XLPE cable (Indoor)
(ii) 3 C x 185 sq.mm 11 KV XLPE cable (Outdoor)
NS Item Supply, Laying of 11 KV 3Cx185 sq mm aluminum armoured (E) XLPE cable. Preferable make – Havells , KEI , Universal, Sterlite
NS Item Supply, Laying of 1.1 KV 3.5 C X 300 sq mm aluminium armored (E) XLPE cable. Preferable make – Havells , KEI , Universal, Sterlite
NS Item Supply, Installation, Testing & Commissioning of LT cable 3.5 X 300 mm2 termination including all accessories and material to make a complete (Gland,Thimble,Nut& Bolt)
NS Item Supply, laying & jointing of 160 mm dia, DWC HDPE pipe laid below 1 mtr including digging and refilling complete in all respect upto entire satisfaction of engineer in charge.
NS Item Supplying & Installation of Danger plate complete in all respect upto entire satisfaction of engineer in charge.
NS Item Supplying & Installation of Fabrication work for Transformer fencing, Road crossing ,Pit cover ,digging work Etc complete in all respect.
Aditya Electrical and Control
GROVER APPLIANCES
ADITYA ENGINEERS & TRADERS
Mukesh Rathee contractor
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .