Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 LAccepted-Finance AIRPORT ROAD SKALZANGLING LEH LADAKH 194101 | LEH LADAKH | LADAKH | 194101 | L1 | Accepted-Finance Being lowest | |
| 2 | L2₹4.7 L+₹8,700 (1.90%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹4.7 L+₹13,500 (2.95%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 |
Tender Value
Refer Docs
Closing Date
12 Jul 2021, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 865 EWS
GE 865 EWS PIN-913865 C/O 56 APO
PROVISION OF THREE PHASE ELECTRIC CONNECTION ALONGWITH 5/15 AMP POINTS AT HAMRC DEPARTMENT OF 153 GH UNDER GE 865 EWS,LEH
2021_MES_457186_1
3011/AQ/02/E3
Limited
Job Works
Works
30 days
LEH
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
Exempted
22 Jul 2021
5 Jul 2021
13 Jul 2021
5 Jul 2021
12 Jul 2021
5 Jul 2021
30 days
1. Supply and Laying in trenches or passing through pipe or fixed on surface XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade of under mentioned sizes : make-Havells/Gloster/Polycab (a) 70 Sqmm 3.5 core - 110 RM (b) 25 Sqmm 3.5 core - 80 RM 2. Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5m in depth for foundation , laying of pipes , cables etc. or for manholes pier holes poles not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in hard /dence soil complete all as specified and directed by engr in Charge - 21.6 Cum 3. Returning filling in soil including spreading levelling watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed by Engr in Charge - 9.80 Cum. 4. Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 above the starting point including spreading and levelling complete all as specified and directed by Engr in Charge - 3.30 Cum 5. Supply,spread & levelling Sand cushioning to underground cables 8 cm below the cable before laying & 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Par-I, complete all as specified and directed by Engr in Charge - 6.50 Cum 6. Supplying and laying Un-reinforced precast concrete pre- cast cover LV type-1Flat size 250x 150x40mm complete all as specified and directed by Engr in Charge - 533 Each 7. M& L of GI Pipe light grade for cable protecton in road crossing of size 40 mm dia complete all as specified and directed by Engr in Charge - 14 RM 8. S&F New sheet metal distribution board iron clad, VTPN Load line, double door with IP-54 1K-09 , 12 ways, protection suitable for MCCB as incomer and MCB as outgoing 415 Volts 3 Phase , complete with appripriate size copper Bus Bar and netural link confirming complete with one MCCB 4 Pole 415 Volts 200 Amp rating, thermal magnetic with rupturing cap 36 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as reqd at site including testing complete all as specified and as directed by the Engr in Charge - 1 Each Job Make- Havells/L&T/Indo Asian 9. S&F MCB Four Pole 415 Volts 100 Amps complete all as specified and directed by Engr in charge - 2 each Make-Havells/C&S/Indo Asian/Legrand 10. S&F MCB DB double door 4 way TPN with suitable Amp rated busbar 415 V complete all as specified and directed by Engr in Charge - 2 Each Make-Havells/C&S/Indo Asian/Legrand 11. S&F MCB DB double door 12 way SPN with suitable Amp rated busbar 240V complete all as specified and directed by Engr in Charge - 4 each Make-Havells/C&S/Indo Asian/Legrand 12. S&F MCB Four Pole 415 Volts 63 Amps complete all as specified and directed by Engr in Charge - 2 each Make-Havells/C&S/Indo Asian/Legrand 13. S&F MCB single phase (SP), 6 to 32 Amps 240 Volts 'C' Curve complete all as specified and directed by Engr in charge - 26 Each Make-Havells/C&S/Indo Asian/Legrand 14. S&F MCB Double pole 63 Amps 240 Volts'C' Curve complete all as specified and directed by Engr in charge - 4 Each Make-Havells/C&S/Indo Asian/Legrand 15. M&L for point wiring with copper conductor cable Multistrand, single core 2.5 Sqmm size for 5 Amps Socket in independent board with 2.5 Sqmm Cable controlled by one switch including one run of 2.5 Sqmm multistrand PVC copper conductor cable for earth continuity in and including PVC casing and capping/PVC Conduit of approved size and quality fixed on walls/ceiling including rectangular PVC board heavy duty type for mounting switches /sockets etc complete all as specified and directed by Engr in Charge - 40 Point Make- Finolex/Havells/Polycab 16. All as per item No 13 above but for power point 3 pin switch socket 15 Amp with PVC copper conductor cable multistrand unsheathed 2.5 Sqmm on independent board incl one run 1.5 Sqmm multistrand PVC copper conductor cable for earth continuity in and including PVC casing and capping fixed on wall incl including MS Sunken box& rectangular PVC board heavy duty type or mounting switches /sockets etc complete all as specified and as directed by Engr in Charge - 20 Point Make- Finolex/Havells/Polycab 17. S&F Gang Box Complete with 5 Amp Switch & socket Combination 240 volts complete all as specified and directed by Engr in Charge - 40 each 18. S&F Gang Box Complete with 15 Amp Switch & socket Combination 240 volts complete all as specified and directed by Engr in Charge - 20 Each 19. Supply and fixing 1100 volts grade heavy duty cable with PVC insulated aluminium conductor (Solid Conductor) served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 sq. mm nominal cross section inservice connectionscomplete all as specified and directed - 120 RM 20. Supply and fix LED flood light fitting 150 Watts, having pressure die cast housing with IP 65 efficient high outout emitter LED for better distribution, protection with heat resistant toughned glass with individual LED lenses complete including making connection with flood light box or OH line using PVC insulated and sheathed single core multi stranded alumn conductor cable of size 1.5 sq mm including MS clamps nuts, bolts and washers of required size complete all as specified and directed by Engr in Charge - 6 Each Make Bajaj/Philips/Havells/CG/Wipro/Syska LED 21. Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground( earth pit not less than 2.25 mtrs deep below normal ground level )with the top edges of plate not less than 1.5 mtrs below normal ground level connected to GI wire 4mm by means of GI nuts, bolts check nuts and washers earth lead protected by 15mm dia GI pipe light grade and connected to main distribution board/earthing test point all as shown in electrical plate No 5 of SSR part 1 and all as specified including testing on completion. Notes:-The unit rate also including for excavation, earth work in any type of strata, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix , type B1 cover reinforced with 8mm dia TMT bars @150mm C/C both ways ,GI funnel with watering pipe ,wire mesh, protection pipe for earth lead upto 7.50m long complete in addition to item No. 1(a) to (e) preamble (notes) under sub heading earthing, specified in SSR Part ll. Earth strip beyond 7.5m shall be measured and paid separately - 1 Each Set
M/S AMCO INDUSTRIES AND EXPORT CORPORATION
osho traders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .