Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.7 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹12.3 L+₹24,380 (2.02%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹12.6 L+₹48,317 (4.00%)Rejected-Finance | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹13.5 L+₹1.4 L (11.6%)Rejected-Finance | L4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | L5₹14.7 L+₹2.7 L (22.1%)Rejected-Finance | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
24 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER
GE970EWS C/O56APO PIN 913970
REPAIR AND MAINT OF EM INSTALLATION BLDS BY NATURE OF BR AND ELECTRICAL WORKS AT MANASBAL UNDER GE 970 EWS
2021_MES_446016_1
GE970EWS-09/2021-22
Open Tender
Civil Works
Item Rate
270 days
GE970EWS
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE970EWS
₹30,000
Yes
3 Feb 2022
27 May 2021
26 Jun 2021
27 May 2021
24 Jun 2021
10 Jun 2021
60 days
Amount
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness below or above ground level complete all as specified and directed
25 mm thick PCC 1:2:4, type B-0 using 12.50 mm graded crushed stone aggregates as in sub floor surfaces, complete all as specified and directed.
Non skid ceramic tiles coloured pattern as required of 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the existing, over with and including 15mm thick screed bed in CM (1:4) after dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
Non skid ceramic tiles coloured pattern as required of 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the existing, over with and including 15mm thick screed bed in CM (1:4) after dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
Glazed ceramic tiles coloured pattern as required 300 x 200 x 7-8 mm thick on vertical surfaces such as dado etc set and jointed in neat cement slurry and pointed in white or colour cement to match the existing, over with after including 10mm thick backing coat in CM 1:3 and incl dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
Machine cut kota stone 18 to 20 mm thick in flooring laid over and incl 20 mm thick screed bed or bedding layer of morter and jointed in grey cement slurry mixed with pigment to match the slab including rubbing and polishing and incl dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
All as per item no 06 but on vertical surfaces complete all as specified and directed
Supply & fixing in repair suspended false celling system using E Grid suspended celling Grid system. The size of Grid shall be 600X600mm with GI frame work, main runner 39X24mm, cross tee 29X24mm and wall angle 22.2X22.2mm including 4mm thick High Pressure Stream cured non primered classic/designer variant E-Board ISI Marked, IS No 14862-2000. Fibre cement E Board to be placed in the gird of E Grid suspended ceiling grid system duly suspended by 4mm dia GI bar hangers from the purlins of the roof complete all as specified and directed
Dismantling plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed
0.63 mm thick galvanized, corrugated mild steel sheeting with grade of zinc coating 275 with two corrugation side lap, fixed with 'L' or 'J' type or crancked hook bolts and washers in roofs, walls etc complete all as specified and directed
All as per item No 10 but except sheeting (any thickness) complete all as specified and directed
Plain, galvanised, 0.63 mm thick mild steel sheeting in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed
Demolition brick work or stone/boulder masonry built in cement mortar incl all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work and precast concrete articles complete all as specified and directed
Brick work with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed
All as per item No 14 above but except bricks complete all as specified and directed
Taking down cement plaster from brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed
Rendering 15mm thick in cement mortar 1:4 on fair faces of brick/concrete surfaces finished even and smooth without using extra cement complete all as specified and directed
Rendering 15mm thick in cement mortar 1:6 on fair faces of brick/concrete surfaces finished even and smooth without using extra cement complete all as specified and directed
Preparation of newly plastered surface of wall and applying two coats of cement base paint over a coat of primer complete all as specified and directed
Preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed
Preparation of old plastered surfaces of wall and applying one coat of cement base paint complete all as specified and directed
Preparation of old plastered surfaces of wall and applying one coat of oil bound distemper complete all as specified and directed
Preparation of old surfaces of ceiling and applying two coats of white wash complete all as specified and directed
Preperation of new steel surface of any description and applying two coat of synthatic enamel paint of approved colour and pattern complete all as specified and directed
Preperation of old decorated steel surface (Corrugated or semi corrugated) roof of any description by brooming down, blowing by blower lamp and washing with water and removal of rubbish from roof surface and applying one coat of synthatic enamel paint of approved colour and pattern complete all as specified and directed
Preparing surfaces of old wood and wood based material of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed
Taking down chowkats or frames not exc 1.5 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed
Taking down chowkats or frames exc 1.5 sqm but n.exc 4 sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed
2nd class hardwood plain solid, straight chowkat and frame, wrought, framed rebated (one or more rebated) on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed.
Factory made 2nd class hard wood 30 mm thick glazed and gauzed skelton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and shutters as specified in SSR Part I, Section 8, clause 8.24 (a) complete all as specified and directed
35mm thick factory made plain framed panelled shutter with lock rail and panel of 9 mm BWP commercial ply or 12 mm to 15mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS-1003 (Part - I) kiln seasoned and chemically pressure treated complete all as specified and directed
Galvanized mild steel wire cloth 0.56 mm nominal dia or wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanized wire staple complete all as specified and directed
3mm thick sheet glass, ordinary quality glazing with oil putty in square n exc 0.50 sqm in each pane complete all as specified and directed
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed
Preparing surfaces of new wood and wood based material of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed
Aluminium alloy, anodised, sliding door bolt 250mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed
Extruded aluminium alloy handles, fabricated type, anodised of 150mm size complete all as specified and directed
Aluminium handle, cast type, anodized 100 mm size ISI Marked complete all as specified and directed
100mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed
200mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed
Butt hinges medium weight cold rolled mild steel 100mm size complete all as specified and directed
Butt hinges medium weight cold rolled mild steel 125mm size complete all as specified and directed
Factory made Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment, incl sand cushioning 25 mm thick below paver block complete all as specified & directed
100mm thick PCC 1:4:8 type D2 using 40mm graded crushed stone aggregates as in sub base, floors etc complete all as specified & directed
75mm thick PCC 1:3:6 type D2 using 40mm graded crushed stone aggregates as in sub base, floors etc complete all as specified & directed
Material and labour in repair Stone kerb (granite or trap stone) of roughly squared stones of size 20cm x 30cm, dressed so that the maximum depression from a straight edge held against the dressed surface shall not exceed 6mm for top and exposed surfaces of sides and 20mm for the rest of surfaces jointed in cement mortar 1:6 and struck flush complete all as specified & directed
S & F in repair vitreous china squatting pan, 'Orissa' pattern, size 580 x 440 mm white, with integral foot rest including trap, flushing pipe and anti-syphonage pipe complete all as specified and directed
S & F in repair PVC valveless, syphonic action, flushing cistern 10 ltr capacity, low level, white, with inlet ball valve, float and handle including brackets complete all as specified and directed
Supply and fixing in repair, 32mm/40mm dia, 800 mm long PVC waste pipe for wash basin, sink , urinal etc complete all as specified & directed
S & F in repair Low density PVC connection commercial quality 450mm long including PTMT nuts at both sides of 15mm bore and fixed complete all as specified and directed
S & F in repair 15 mm bore CP bib taps cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed
S & F in repair 15 mm bore stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed
Supply and fixing in repair for vitreous china wash hand basin white, flat back of size 550 x 400 mm white including waste fittings, brass chromium plated coupling, brackets including cutting for and pinning in ends of brackets errect stand, fixing waste pipe complete all as specified & directed
Supply and fixing in repair for grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified & directed
Taking down carefully existing point wiring aluminum/ copper conductor for light or fan or socket or power etc on wooden batten or in conduit including fittings and accessories like switches, sockets, wooden board and making good disturbed portion to match with existing complete all as specified and directed.
Taking down old and unserviceable submain wiring/ service cable any size of two core including earth wire complete including batten/ conduit and make good the disturbed surface to match the existing surface, all as directed
Taking down old and unserviceable, distribution board any type including fuses, MCBs etc after removing all connections and making good the disturbed surface all as directed
Material & labour for point wiring complete with single core 1.5 Sqmm (nominal area) PVC insulated multistranded, copper conductor cable (FRLS) drawn through and including PVC conduit 25 mm bore (ISI marked) and accessories (fixed on wall/ceiling surfaces), terminated in and including pressed steel terminal boxes with plastic laminated backlite sheet top cover 3 mm thick (hylum) fixed with nickel polished screws with washers, earth continuity PVC cable(FRLS), copper conductor 1.5 Sqmm (nominal area) stranded with green insulation earth wire connected with earth dolly One light point / fan point / bell push point controlled by one way switch 5 Amprs and/or through regulator complete all as specified and directed. Note : - Wiring should be in proper clour coding (Red, Yellow and blue for Phase, Green for earthing and Black for neutral)
All as per description of srl item No 59 here-in-before but socket out let 3 pin, 5 Amp on same board with other switch.
All as per description of srl item No 59 here-in-before but socket out let 3 pin, 5 Amp on independent board with other switch.
All as per description of srl item No 59 here in before but using 2.5 sqmm (nominal area) PVC stranded copper conductor cable with 2.5 Sqmm PVC insulated copper cable for continuous earth continuity conductor for 3 pin socket out let 15 Amps on independent board.
All as per description of srl item No 59 here in before but using 4 sqmm (nominal area) PVC stranded copper conductor cable with 4 Sqmm PVC insulated copper cable for continuous earth continuity conductor for 3 pin socket out let 15 Amps on independent board.
Switch piano flush type, 5 Amps, 240V AC, single pole, one way complete all as specified and directed .
Socket outlet 3 pin, 5 Amp, 230 V AC complete all as specified and directed.
Switch socket combination 2 in 1, 5 Amps 240 V AC flush type universal, complete all as specified and directed.
Switch socket combination 5 in 1, 3 pin 5/15 Amps 240 V AC flush type universal, complete all as specified and directed.
Sheet metal enclosures for DB's with 200 Amp rated bus bar double door class IP-43 epoxy coated inside and outside 8 way SPN 240 volts complete all as specified and directed.
All as per description of srl item No 68 here-in-before but 12 way SPN
All as per description of srl item No 68 here-in-before but 4 way TPN
MCB TPN 63 Amp, 240 volts,10 KA, complete all as specified and directed. Make: Havells DHMCDFP063 in 'D' Series/ L&T/SCHNIDER
MCB SPN 63 Amp, 240 volts,10 KA, C-curve complete all as specified and directed. Make: Havells Cat No DHMGCSNF040 IN "C' Series/ L&T/SCHNIDER
MCB SP 6 to 32 Amp, 240 volts,10 KA, C-curve complete all as specified and directed. Make: Havells Cat No DHMGCSNF6-32 IN "C' Series/ L&T/SCHNIDER
Ceiling rose 3 terminals complete all as specified and directed
Supply and fix in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. complete all as directed and specified
Supply and fix in repair lamp holder batten/angular type complete all as specified and directed.
Supply and fix in repair 1x15W LED lamp white pin type complete all as specified and directed.
Supply and Fixing in repair 1X18 watt 4 ft long LED Batten housing made of extruded alluminium with milky white diffuser and inbuilt electronic driver system lumen output should be at least 1800 lumen with a CCT of 6000 K, power factor should be greater than 0.95 with all accessories and connecting up with 3 core flexible cable white of size 23/0.0076 complete all as specified and directed. make : Havells Cat part No : LHEXBQP6IN1W018 or equivalent in : BAJAJ /Philips/CG. Note (i) Contractor shall provide 2 years written manufacturer's warranty for the LED fixture complete including driver from the certified date of completion. (ii) Contractor shall produce LM-79 & LM-80 report of NABL accedited labortory from manufaturers.
Supply and fix in repair 1X09 watt 2 ft long LED Batten housing made of extruded alluminium with milky white diffuser and inbuilt electronic driver system lumen output should be at least 1800 lumen with a CCT of 6000 K, power factor should be greater than 0.95 with all accessories and connecting up with 3 core flexible cable white of size 23/0.0076 complete all as specified and directed. make : Havells Cat part No : LHEXBQP6IN1W009 or equivalent in : BAJAJ /Philips/CG Note (i) Contractor shall provide 2 years written manufacturer's warranty for the LED fixture complete including driver from the certified date of completion. (ii) Contractor shall produce LM-79 & LM-80 report of NABL accedited labortory from manufaturers.
Material and labour for sub main wiring with two runs of single core PVC insulated (FRLS) unsheathed copper conductor multistranded cable of size 4 sqmm 1100 volts grade drawn through in & including PVC conduit 25mm dia & 2.5 sqmm single core copper conductor multistranded PVC insulated (FRLS) unsheathed cableas earth wire continuity conductor complete all as specified and directed. Note : (i) Two run of cable 4 sqmm and one run of 2.5 sqmm earth wire shall be measured and paid as one unit only. (ii)Phase should be Red / Yellow / Blue, neutral should be black and earthing wire should be green in colour
Supply, laying and testing of UG XLPE insulated, armoured heavy duty electric cable with aluminium conductor ISI marked as per IS-7098 (Part-I), 1100 Volts grade, cross-sectional area 10 sqmm 2 Core laid in trenches/pipes, fixed to poles/walls with suitable saddle & glands incl taking out the old burnt out cable complete all as specified and directed.
All as per item No. 81 above but 16 Sqmm 4 core.
M&L Earthing complete with GI earth plate 60cmx60cmx6mm thick electrode and 4mm dia GI wire as earthing lead burried directly in ground ( earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level. connected to GI wire earth lead 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-I and incl earth work,PCC pit and RCC cover,watering pipe 20 mm dia light grade,funnel,wire mesh,protection pipe 15 mm dia light grade up to 7.5 mtr length of earth wire,charcoal dust and salt etc and connected to earthing test point incl taking out old complete all as specified and as directed.
M/S NAZIR CONSTRUCTION
M/S MIR SAJAD ENTERPRISES
M/S FAYAZ AHMAD BHAT
NAJAR ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .